Chapter 6: Check Valves
|
|
- Scarlett Higgins
- 7 years ago
- Views:
Transcription
1 Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/ Shuttle valves SSR -2 Check valves, direct operated RK / R CS SPZE SPV / SPZ C4V CPS C4V Check valves, pilot operated 2/2 way seat valves D4S -21 Accessories Plugs -31 Subplate Screw-in Slip-in More check valves are presented in the following chapters: Chapter 7: Sandwich Valves Chapter 8: Slip-In Cartridge Valves Chapter 9: SAE Flange Valves Chapter 10: Valves for Pipe Mounting content0.indd CM
2 Characteristics / Ordering Code Shuttle Valve Series SSR The shuttle valve series SSR is designed as a threaded cartridge valve. All parts are assembled in one unit and easy to mount. Features Little space required Leak-free Easy assembly Ordering code SSR 080 E Code omit V Seal NR FPM Seal Shuttle valve Design series Factory norm, direct operated Threaded cartridge Valve size Code Size 0 NG0 10 NG10 Technical data General Design Threaded cartridge valve Mounting position Unrestricted Ambient temperature [ C] Nominal size NG0 NG10 Weight [kg] Hydraulic Flow direction See symbols Fluid Hydraulic oil as per DIN Viscosity, recommended permitted [cst] / [cst] / [mm²/s] [mm²/s] Fluid temperature [ C] Filtration ISO 440 (1999); 18/1/13 Nominal pressure [bar] 350 Flow [l/min] 40 0 SSR UK.indd CM
3 Dimensions Shuttle Valve Series SSR Dimensions NG0 NG10 D L d M18x1.5 M24x1.5 l 45 SW 8 12 Tightening torque 1) [Nm] ± 15 % 40 5 Mounting cavity Dimensions NG0 NG10 d d2 M18 x 1.5 M24 x 1.5 d3 H d4 H d5 max. 9 d max. 9 t t t t t t Seal kits NG NR seals FPM seals 0 SK-SSR0E0 SK-SSR0E0V 10 SK-SSR0E10 SK-SSR0E10V 1) Please note the material specification for tightening torque in chapter 12, "accessories" SSR UK.indd CM
4 Characteristics / Ordering Code The check valves series RK and R are designed to go into simple, threaded cavities. The connection is O-ring sealed on the 118 shoulder in the mounting cavity. The valve body is supplied as a unit, with a spring loaded, hardened and polished semisphere of stainless bearing steel inside. The seat is also hardened and ground. Threaded Check Valves Series RK, R Type RK Type R Ordering code R Check valve, screwable Mounting direction Size Code K Mounting direction in the blocked direction in open flow direction Code Flow [l/min] Thread 0 1) 10 G1/8A 1 20 G1/4A 2 50 G3/8A 3 80 G1/2A 1) Only series RK available Technical data Series design with pipe thread Code RK0 RK1 RK2 RK3 R1 R2 R3 Flow [l/min] Operating pressure [bar] Opening pressure [bar] Thread (DIN ISO 228/1) G1/8A G1/4A G3/8A G1/2A G1/4A G3/8A G1/2A Tightening torque* ±20 % [Nm] Weight [g] Mounting position unrestricted Fluid Hydraulic oil in accordance with DIN Viscosity permitted [cst]/[mm²/s] ; opt viscosity recommended Temperatures [ C] Ambient and oil , observe viscosity range * In case of strong vibration, it is recommended to secure the mounting threads. RK-R UK.INDD CM
5 Characteristic Curves / Mounting p/q performance curves Type RK Threaded Check Valves Series RK, R Type R All characteristic curves measured with HLP4 at 50 C. Mounting direction Type RK Type R Screwed in, in the blocked direction Screwed in, in the open flow direction Mounting tool Type RK Type Ordering number D 2 a d 3 RK RK RK RK RK-R UK.INDD CM
6 Dimensions Type RK Threaded Check Valves Series RK, R Type R Type Thread L l 1 d d 1 d 2 h d.c. O-ring RK0 G1/8A x1 RK1 G1/4A x1 RK2 G3/8A x1.5 RK3 G1/2A x1.5 Type RK Type Thread L l 1 d d 1 h ww O-ring R1 G1/4A x1 R2 G3/8A x1.5 R3 G1/2A x1.5 Type R Type Thread D D 1 t t 2) 1 x 1) RK0 G1/ RK1 and R1 G1/ RK2 and R2 G3/ RK3 and R3 G1/ Type Thread D D 1 t t 2) 1 x 1) a 1 d 2 RK0 G1/ RK1 and R1 G1/ RK2 and R2 G3/ RK3 and R3 G1/ Mounting cavity for connecting in combination with tube fitting for internal line channels * Required depth depending on type of screw plug, connecting plate etc. used. 1) Thread runout x must be maintained. It may be smaller, but not larger (requirement for a perfect seal using the O-ring). 2) Fully cut-out thread RK-R UK.INDD CM
7 Characteristics / Ordering Code Manatrol check valves of the series CS for subplate mounting provide free flow in one direction and block flow in the counter direction. Specific Manatrol poppets and poppet guides ensure reliable functional integrity even at high flow rates and/ or pulsations. Check Valve Series CS Ordering code CS S Code Size (1/4) (3/8) (1/2) (3/4) (1) Manifold design Nominal size Steel body Opening pressure Seal Code omit V Seal NR FPM Code Pressure [bar] omit Technical data Size Operating pressure [bar] Pressure drop p [bar] Flow [l/min] MTTF D value [years] 150 CS UK.INDD CM
8 Characteristic Curves / Dimensions p/q performance curves Check Valve Series CS All characteristic curves measured with HLP4 at 50 C. Dimensions Size ØD ØA L L1 L2 L3 L4 L H H1 H2 H3 Weight [kg] CS 400S CS 00S CS 800S CS 1200S CS 100S CS UK.INDD CM
9 Characteristics / Ordering Code The check valves series SPZE are slip-in cartridge valves. The function unit is fixed inside the manifold by a hexagonal plug with slot. The design is based on CE series with same poppet and sleeve. The different mounting cavity has to be considered. Features Little space required Leak-free from port to A 4 different opening pressures Check Valve Series SPZE Ordering code SP Z E 1010 E Code omit V Seal NR FPM Code Size 1 NG1 25 NG25 32 NG32 Seal Check valve Flow direction A to Design series, screwed cover Factory norm, poppet, direct operated Slip-in valve Valve size Opening pressure Code Pressure [bar] L 0.1 N 0.5 S 1. U 4.0 Technical data General Design Threaded cartridge valve Nominal size NG1 NG25 NG32 Mounting position Optional Ambient temperature [ C] MTTF D value [years] 150 Weight [kg] Hydraulic Flow direction Port A to Fluid Hydraulic oil according to DIN Viscosity, recommended [cst] / [mm²/s] permitted [cst] / [mm²/s] Fluid temperature [ C] Filtration ISO 440 (1999); 18/1/13 Nominal pressure [bar] 350 Opening pressure [bar] 0.1; 0.5; 1. and 4.0 Flow [l/min] SPZE UK.INDD CM
10 Performance Curves / Dimensions p/q performance curves Check Valve Series SPZE Dimensions Volume flow [l/min] All characteristic curves measured with HLP4 at 50 C. Dimensions NG1 NG25 NG32 D L d M33x2 G1½" G2" l SW Tightening torque 1) [Nm] ± 15 % Springs Ordering Number Spring Type NG1 NG25 NG32 L 0.1 bar N 0.5 bar S 1. bar U 4.0 bar Mounting cavity t2 t4 t3 15 ødmin ød5 Rmax 8 0.5min tmin t5 max Ø tmax - tmin tmax Size NG1 NG25 NG32 d d2 H d d5 M33x2 G1½" G2" d min t t t t t min t max Seal kits ød1 ød2 ød3 NG NR seals FPM seals 1 SK-SPZE10E1 SK-SPZE10E1V 25 SK-SPZE10E25 SK-SPZE10E25V 32 SK-SPZE10E32 SK-SPZE10E32V 1) Please note the material specification for tightening torque in chapter 12, "accessories" SPZE UK.INDD CM
11 Characteristics / Ordering Code The check valve series SPV and SPZ are designed as threaded cartridge valves. All parts are assembled in one unit and easy to mount. Features Little space required Leak-free Easy assembly Check Valves Series SPV, SPZ Ports Flow direction V Flow direction Z Ordering code SP 030 E M Code omit V Seal Seal NR FPM Check valve Flow direction Design series Factory norm, direct operated Threaded cartridge Valve size Spring 0.3 bar Code Size 0 NG0 10 NG10 Code V Z Flow direction Port A and C Port A and C Technical data General Design Threaded cartridge valve Nominal size NG0 NG10 Mounting position Unrestricted Ambient temperature [ C] Weight [kg] Hydraulic Flow direction See symbols Fluid Hydraulic oil according to DIN Viscosity, permitted [cst] / [mm²/s] recommended [cst] / [mm²/s] Fluid temperature [ C] Filtration ISO 440 (1999); 18/1/13 Nominal pressure [bar] 350 Opening pressure [bar] 0.3 Flow [l/min] 40 0 SPV-SPZ UK.INDD CM
12 Performance Curves / Dimensions p/q performance curve Check Valves Series SPV, SPZ Dimensions Characteristic curves measured with HLP4 at 50 C. Mounting cavity Dimensions NG0 NG10 D L d M18x1.5 M24x1.5 l 45 SW 8 12 Tightening torque 1) [Nm] ± 15 % 40 5 Dimensions NG0 NG10 d d2 M18 x 1.5 M24 x 1.5 d3 H d4 H d5 max. 9 d max. 9 t t t t t t Seal kits NG NR seals FPM seals 0 SK-SPV/Z0E0 SK-SPV/Z0E0V 10 SK-SPV/Z0E10 SK-SPV/Z0E10V 1) Please note the material specification for tightening torque in chapter 12, "accessories" SPV-SPZ UK.INDD CM
13 Characteristics / Ordering Code Direct operated check valves C4V allow free flow from A to. The counter direction is blocked. The C4V series are equipped with a leak-free seat type cartridge. Function The pressure arising in port A lifts the poppet from the valve seat and releases the flow to. In the counter direction, the spring and the pressure on top of the cartridge hold the poppet onto the seat and block the flow. Check Valve Series C4V C4V0 Ordering code C4V10 C4V Check valve direct operated Nominal size Max. pressure 350 bar Subplate mounting Approx. cracking pressure Design series Seal Options Code Nominal size 03 NG10 0 NG25 10 NG32 C4V UK.INDD CM Code Seal 1 NR 5 FPM Approx. cracking pressure [bar] Code C4V03 C4V0/
14 Technical Data / Performance Curves Technical data Check Valve Series C4V General Nominal size NG10 NG25 NG32 Subplate mounting ISO 5781 Mounting position unrestricted Ambient temperature [ C] MTTF D value [years] 150 Weight [kg] Hydraulic Max. operating pressure [bar] 350 Nominal flow [l/min] Fluid Hydraulic oil according to DIN Viscosity, permitted [cst] / [mm²/s] recommended [cst] / [mm²/s] Fluid temperature permitted [mm²/s] recommended [mm²/s] Filtration ISO 440 (1999); 18/1/13 p/q performance curve Characteristic curve measured with HLP4 at 50 C. C4V UK.INDD CM
15 Dimensions Check Valve Series C4V NG ISO-code x1 x2 x3 x4 x5 y1 y2 1 2 H1 H2 H3 L1 L Tolerance for all dimensions ±0.2 NG ISO-code d1max d2 t1 d3 t2 d4 d M M M NG ISO-code olt kit NR FPM Surface finish K 505 4x M10 x 35 ISO Nm ±15 % S S K 485 4x M10 x 45 ISO Nm ±15 % S S K 50 x M10 x 45 ISO Nm ±15 % S S C4V UK.INDD CM
16 Characteristics / Ordering Code Pilot Operated Check Valve Series CPS Pilot operated check valves of the series CPS allow free flow in one direction (A to ). The counter-flow direction ( to A) is blocked. y applying pilot pressure, the poppet can be lifted from its seat against the pressure in port. Thus flow in the counterdirection is also possible. There are 1 and 2 stage poppets available with pilot ratios of 5 : 1 and 40 : 1, to suit different operating conditions. The CPS needs to be externally drained via port L. Ordering code CP S S M Code Port size (") (¾") Pilot operated check valve Manifold mounting Port size Steel body Pilot ratio Steel poppet Seal Code omit V Seal NR FPM Code Ratio Stage 5 5: :1 2 Pilot ratios Poppet 1 stage Poppet 2 stage Surface ratio 5 : 1 (pilot spool: poppet surface) for quick response time without decompression. Surface ratio 40 : 1 (pilot spool: decompression pin surface) for low shock or oscillation performance from decompression. Technical data Size Max. operating pressure [bar] Max. pilot pressure [bar] Flow Q max atp 2.7 bar [l/min] Weight [kg] 4 7 CPS UK.INDD CM
17 Performance Curves / Dimensions Pilot Operated Check Valve Series CPS p/q performance curves All characteristic curves measured with HLP4 at 50 C. Dimensions H1 A H L A to free flow direction L7 L8 H (free flow outlet ): Ø 19.1 H (free flow inlet A): Ø 19.1 Drain size 00 and 1200: Ø 7.1 Pilot size 00: Ø 7.1 size 1200: Ø mounting screws M8 for size 00 mounting screws M10 for size 1200 H2 2 1 L5 L4 L3 L2 H3 L1 SW 25.4 (00) SW 38.0 (1200) L9 L11 L10 Size L3 L2 L1 L9 L11 H H1 H2 H3 L10 L8 L7 L ØH L5 L4 CPS00S CPS1200S CPS UK.INDD CM
18 Characteristics Hydraulically pilot operated check valves C4V allow free flow from A to. The counter-flow direction is blocked. When pressure is applied to control port X, the ring chamber flow from to A is released. Up to four different pilot control ratios are available (see ordering code). Function When no pressure is applied to the X-port, the flow from to A is blocked, because the pressure in is also in effect on top of the poppet. Pressurizing the X port relieves the area on top of the poppet to the drain port and allows flow from to A. The seat design of the SVL valve series provides leak-free separation of port A and in the closed position. Hydraulically Pilot Operated Check Valve Series C4V Valves with position control are available on request. C4V pilot oper. UK.INDD CM
19 Ordering Code / Technical Data Hydraulically Pilot Operated Check Valve Series C4V Ordering code C4V 5 9 Check valve pilot operated Nominal size Max. pressure 350 bar Y1-port G¼" Opening ratio Approx. cracking pressure Design series Seal Options Code Nominal size 03 NG10 0 NG25 10 NG32 Code Opening ratio 1 1 : : : : 1 Technical data Code Seal 1 NR 5 FPM Code Approx. cracking pressure [bar] Flow A to Flow to A C4V03 C4V0/10 C4V03 C4V0/ General Nominal size NG10 NG25 NG32 Subplate mounting ISO 5781 Mounting position Unrestricted Ambient temperature [ C] MTTF D value [years] 150 Weight [kg] Hydraulic Max. operating pressure [bar] 350 Nominal flow [l/min] Fluid Hydraulic oil according to DIN Viscosity, recommended [cst] / [mm²/s] permitted [cst] / [mm²/s] Fluid temperature recommended [ C] permitted [ C] Filtration ISO 440 (1999); 18/1/13 p/q flow curve Characteristic curve measured with HLP4 at 50 C. C4V pilot oper. UK.INDD CM
20 Dimensions Hydraulically Pilot Operated Check Valve Series C4V L1 L2 X2 X1 X5 X4 d4xt4 Y1 1 Must be closed by counterpart A Ød1 Y3 Y2 Y1 2 X L5 L3 L4 Ød2 X X7 Ød3xt3 Ød Y1 to tank Ød5 H3 H1 H2 NG ISO-code x1 x2 x3 x4 x5 x x7 y1 y2 y3 y4 y5 y Tolerance for all dimensions ±0.2 NG ISO-code 1 2 H1 H2 H3 H4 H5 H L1 L2 L3 L4 L5 L NG ISO-code d1max d2max d3 t3 d4 t4 d5 d M M M NG ISO-code olt kit NR FPM Surface finish K 505 4x M10 x 35 ISO Nm ±15 % S S K 485 4x M10 x 45 ISO Nm ±15 % S S K 50 x M10 x 45 ISO Nm ±15 % S S C4V pilot oper. UK.INDD CM
21 Characteristics Directional Seat Valve Series D4S Seat valves series D4S are designed for directional control functions. A large variety of poppets, springs and covers including shuttle valves, stroke limiters, solenoid valves (VV01) and position control allow to design individual hydraulic solutions for nominal flow up to 00 l/min. A complete program of 2/2-way seat valves is offered under Parker brand: subplate mounted valves series D4S chapter SAE flange valves series D5S chapter 9 slip-in cartridges series CAR on request Features Subplate mounting according to ISO 5781 Leak-free seat valve design Numerous pilot options poppet types D4S03 - NG10 D4S0 - NG25 D4S10 - NG32 D4S10-9DC Pilot oil Y = internal from D4S UK.INDD CM
22 Ordering Code Directional Seat Valve Series D4S D4S 9 Seat valve Nominal size Code Nominal size 03 NG10 0 NG25 10 NG32 Subplate mounting ISO 24, Y1 port G¼" Code Pilot oil line in body A-X -Y 1 internal from A 2 external from X A 1) internal from A external from X C internal from A + D internal from G external from Y Code Sleeve 1 AA = 95 %, A = 5 % 3 AA = 0 %, A = 40 % Pilot connection Cap version Code Ports X Y Z X-Y Y1 VV01 Standard 1 Pilot oil = pilot drain C Pilot oil = pilot drain With solenoid valve (VV01) 2 Ext. PD from cap 5 Ext. to subplate Internal pilot drain With stroke limiter (not for D4S03) 3 Pilot oil = pilot drain 4 Pilot oil = pilot drain open bore closed bore orifice Ø 1.2 Sleeve Code Size Poppet type Sleeve 1 03, 0,10 With closed bottom and 15 chamfer (pz max. = pa +20 bar) 1 03 With 0.8 dia. orifice at the bottom and 2 15 chamfer 1 0, 10 With 1.2 dia. orifice at the bottom and 15 chamfer , 0,10 With closed bottom and 45 chamfer 1, 3 A 2) 0, 10 Safety spool (for position control only) 3 2) 0, 10 Throttle spool, 10 chamfer 3 C 2) 0, 10 Throttle spool, 3 chamfer 3 Spring (approx. cracking pressure [bar]) Code Sleeve Code 1 Sleeve Code 3 A A A D5S03 D5S0/10 D5S03 D5S0/10 D5S03 D5S0/ Examples see end of chapter Spool type Spring Switching type Solenoid voltage Design series Code omit 013 Seals Options Standard Cover for end position control Code Switching type omit Standard w/o vent function VV01 with manual override VV01 without manual override power open de-energized: comp. 11 VV01 with manual override 12 VV01 without manual override power closed de-energized: comp. CA DA C CD D DD H K N Q C E A F L Shuttle valve Shuttle valve Code Seals 1 NR 5 FPM Options Code Solenoid voltage omit Standard w/o vent function G0R 12 V= G0Q 24 V= GAR 4) 98 V= GAG 4) 205 V= W V / 50 Hz 120 V / 0 Hz W V / 50 Hz 240 V / 0 Hz VV01 code 09 and shuttle valve code CA VV01 code 11 and shuttle valve code CA VV01 code 09 and shuttle valve code DA VV01 code 11 and shuttle valve code DA VV01 code 10 and shuttle valve code CA and position control 3) with amplifier VV01 code 12 and shuttle valve code CA and position control 3) with amplifier VV01 code 10 and shuttle valve code DA and position control 3) with amplifier VV01 code 12 and shuttle valve code DA and position control 3) with amplifier VV01 code 10 and position control 3) with amplifier VV01 code 12 and position control 3) with amplifier Position control 3) with amplifier Position control 3) with amplifier and shuttle valve code CA Position control 3) with amplifier and shuttle valve code DA 1) With VV01 only. 2) Springs 2, 3 and only. 3) Position control for D4S0/10 only. Spring 2 or 4. Spool A and sleeve 3. Valve open: proximity switch damped. 4) To be used in combination with rectifier plugs at 120 VAC/230 VAC power supply. D4S UK.INDD CM
23 Technical Data Directional Seat Valve Series D4S General Size NG10 NG25 NG32 Mounting interface Subplate mounting according to ISO 24 Mounting position unrestricted Ambient temperature [ C] MTTF D value [years] 150 Weight [kg] Hydraulic Operating pressure [bar] Ports A, up to 350; Port Y 140 (with VV01) Nominal flow [l/min] Fluid Hydraulic oil according to DIN Fluid temperature [ C] Viscosity permitted [cst] / [mm 2 /s] Viscosity recommended [cst] / [mm 2 /s] 30 Filtration ISO 440 (1999); 18/1/13 Electrical (solenoid) Duty ratio 100 % ED; CAUTION: coil temperature up to 150 C possible Protection class IP5 in accordance with EN 0529 (with correctly mounted plug-in connector) Code G0R G0Q GAR GAG W30 W31 Supply voltage [V] 12 V = 24 V = 98 V = 205 V = 110 at 50 Hz 230 at 50 Hz 120 at 0 Hz 240 at 0 Hz Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5 Current consumption hold [A] / / 0.27 in rush [A] / / 1.2 Power consumption hold [W] / 70 VA 70 / 70 VA in rush [W] / 290 VA 280 / 290 VA Solenoid connection Connector as per EN , solenoid identification as per ISO 941 Wiring min. [mm 2 ] 3 x 1.5 recommended Wiring length max. [m] 50 recommended D4S pilot configuration D4S direct operated D4S with vent valve VV01 VV01 Y1 X-Y X Z Y VV01 AZ AA A A-X X A -Y Y de-energized open Z Y Z1 de-energized closed Z Y Z1 D4S UK.INDD CM
24 Performance Curves / Cartridges p/q performance curves Directional Seat Valve Series D4S Leakage All characteristic curves measured with HLP4 at 50 C. Selection of Cartridges Sleeve 1, poppet 1 Sleeve 1, poppet 2 Sleeve 1, poppet 4 Sleeve 3, poppet 4 Sleeve 3, poppet A Sleeve 3, poppet /C Z Z Z Z Z Z A A A A A A 1 : : : : : : 1.7 A A = 0.95 A C A A = 0.95 A C A A = 0.95 A C A A = 0. A C A A = 0. A C A A = 0. A C A = 0.05 A C A = 0.05 A C A = 0.05 A C A = 0.4 A C A = 0.4 A C A = 0.4 A C 15 chamfer 15 chamfer 45 chamfer 45 chamfer 45 chamfer 45 chamfer orifice safety spool throttle spool D4S UK.INDD CM
25 Dimensions Directional Seat Valve Series D4S NG ISO-code X1 X2 X3 X4 X5 X X7 Y1 Y2 Y3 Y * * * NG ISO-code 1 2 H1 H2 H3 L1 L2 D1 D2 D3 t1 D4 t2 D5 D * M * M * M NG ISO-code olt kit NR FPM Surface finish *-97 K 505 4x M10 x 35 ISO Nm ±15 % S S *-97 K 485 4x M10 x 45 ISO Nm ±15 % S S *-97 K 50 x M10 x 45 ISO Nm ±15 % S S D4S UK.INDD CM
26 Dimensions Dimensions D4S with VV01 Directional Seat Valve Series D4S Y1 with manual override without manual override Z1 D4S VV01 D4S /12 Solenoid energized: Flow from A- or -A Solenoid de-energized: D4S blocked X A Y Dimensions D4S with shuttle valve Y1 cap Z1 vent valve VV01 shuttle valve (pilot oil from A and ) body version series D4S Code C or CD X A Y1 Y cap () Dimensions in brackets are for version VV01with shuttle valve code D or DD. Z1 vent valve VV01 shuttle valve 1) Code D or DD body version series D4S 1) Pilot oil from A and, from to A check valve function. X A Y D4S UK.INDD CM
27 Dimensions Dimensions D4S position control Directional Seat Valve Series D4S Position control by proximity switch (incl. amplifier) Valve open: proximity switch activated. This proximity switch is pressure proof and has no wearing parts. Note Position control for D4S0 and D4S10 only. Technical data (proximity switch) Function PNP, contact Supply voltage (Us) [VDC] Supply voltage ripple [%] 10 Current consumption [ma] max. 8 Residual voltage L-signal [V] Us at l max Output current (I) [ma] 200 Protection class IP7 Ambient temperature [C ] Wire cross section [mm 2 ] 3 x 0.5 Dimensions D4S stroke limiter Note: Stroke limiter not for use with D4S03, vent valve VV01, shuttle valve and positon control. D4S UK.INDD CM
28 Ordering Code Explanation (Examples) D4S direct operated Directional Seat Valve Series D4S D4S with VV01 D4S UK.INDD CM
29 Ordering Code Explanation (Examples) D4S with VV01 Directional Seat Valve Series D4S D4S with shuttle valve D4S UK.INDD CM
30 Ordering Code Explanation (Examples) D4S with position control Directional Seat Valve Series D4S D4S with stroke limiter D4S UK.INDD CM
31 Plugs Check Valves Accessories Description Threaded cable joint Plug DIN 4350, design type AF, protection class IP 5 Voltages up to 250 V PG 9 PG11 ody colour coding black, grey, A black, grey, A Figures switching Fig. 1 Fig. 1 Order no For other plugs see chapter 2, "Accessories" access0.indd CM
Chapter 5: Flow Valves
Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free
More information2/2 and 3/2 Way Size 6 Seat Valves
2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08
More informationSOLENOID VALVES 3-4 WAY
SOLENOID VLVES - WY IE/C// CT: FP/VCR Page: 7 SHEET: / SOLENOID VLVES - - WY CV SOLENOID VLVES -WY/-POSITION /- UNF.7 5.7 The electric valve is a -way -position directional electrically controlled Slight
More informationFluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.
Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power
More informationSafety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage
Safety for Hydraulics Leak free double check valve, pilot operated, series Cartridge type, two stage 8 1 1 General description spring closed, pilot operated, cartridge type poppet valve it holds the load
More information3/2 Solenoid Cartridge Valve, Size 6
/ Solenoid Cartridge Valve, Size 6 Q max = l/min, p max = 5 bar Bidirectional seat-valve shut-off, direct acting Guided valve spool and poppet Two spool variants are available Available in two mounting
More information3/2- and 2/2-way cartridge valve type BVE
3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type
More informationRPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007
Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid
More informationCartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)
Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers
More informationDXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30
85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationE4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51
83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE
More informationPressure reducing valve, direct operated, Type ZDR 6 D
RE 26 57/2.3 Replaces:.2 Pressure reducing valve, direct operated, ype ZDR 6 D Nominal size 6 Series 4X aximum operating pressure 2 bar aximum flow 5 L/min K 4279/ ype ZDR 6 DP2 4X/ Y Overview of contents
More informationCheck Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits
Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot
More information3/2-way Mini Solenoid Valve
3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug
More informationSafety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage
Safety for Hydraulics Leak free check valve, pilot operated, series Cartridge type, two stage prevents a load from falling if a burst occurs in feed pipe hardened seat and poppet prevents creep of hydraulically
More information3 Port Solenoid Valve
Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large
More informationSingle sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
More informationSystem 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8
System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures
More informationChapter 7: Sandwich Valves
Contents Chapter : Sandwich Valves Series Parker Denison Description Size Page DIN / ISO 06 10 16 25 Pressure relief valves, manual operation RDM Direct operated -2 RM Pilot operated -6 ZDV Pilot operated,
More informationFlow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB.. 1.1 Generals. 1.2 Application examples. 2.2 3-way flow control. 2.1 2-way flow control
Flow Control Valve Series SRCB.. plug-in solenoid for easy coil change flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports energy - optimised
More informationD634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05
D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 GENERAL SECTION PAGE MOOG SERVO- AND PROPORTIONAL CONTROL VALVES General 2 enefits and Functionality 3 General
More informationInrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.
Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the
More informationElectrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
More informationElectro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
More informationSensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm
Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders
More informationD660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10
D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 OVERVIEW D660 Section Page MOOG SERVO-PROPORTIONAL CONTROL VALVES Overview 2 3 Technical Data 4 5 Electronics
More informationDenotes New Winner s Circle Product Line. Catalog HY15-3502/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY
Catalog HY-5/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI HIGH FLOW VALVE FAMILY See individual catalog pages for exact specifications. WAY SPOOL TYPE GS *... X / C9-.. Position,
More information3/2-way pneumatic cartridge solenoid valve
3/2-way pneumatic cartridge solenoid valve Compact design with 11 mm width per station Orifices from 0.5 mm (9 bar) to 1.2 mm (1.5 bar) High durability and reliability Low power consumption, as well as
More informationLine-Mounted Valves L Series
Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationValve systems Base plates, according to standard ISO 5599-1. Brochure
ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure
More informationPRE3G 81 250/212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12
81 250/212 ED PRE3G PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS SUBPLATE MOUNTING ISO 4401-03 (CETOP 03) p max 350 bar Q max 40 l/min MOUNTING SURFACE OPERATING
More information*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type... 5/132...
More information1. General. D 7490/1 2/2-way cartridge valve EM 2.2. Operation pressure p max Flow Q max. = 450 bar = 160 lpm. Cartridge valve (see section 2)
2/2-way directional seated s type EM and EMP for oil hydraulic systems, leakage free in blocked state, available as on/off, soft-shift or proportional Operation pressure p max Flow Q max = 4 bar = 0 lpm
More information2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description
More informationDSE5J 83 280/112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05)
83 280/112 ED DSE5J DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05) p max 320 bar Q max 180 l/min MOUNTING SURFACE OPERATING
More information3 Port Solenoid Valve
ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.
More informationCheck Valves Valve locator
Check Valves Valve locator Functional Symbol Flow Typical Model Cavity Rating Pressure Page Check valve, direct L/min (USgpm) bar (psi) FPR/4 Inline () 5 (5) - FPR/8 Inline (8) 5 (5) - FPR/ Inline 45 ()
More information*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type...
More informationG1/4 Q8. Standard with biased position
Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,
More information3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow
1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control
More informationProportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32
www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional
More informationPressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.
Vickers Pressure Relief Pressure Relief and Sequence Valves CG2V-6/8, 1 Series; CG5V-6/8, 2 Series Typical Section CG2V-6*W-1 relief valve Basic Characteristics Maximum pressure.......... 35 bar (5 psi)
More informationLoad-sensing control block in mono and sandwich plate design
Load-sensing control block in mono and sandwich plate design RE 64276/08.2010 Replaces: 08.2008 1/64 Type M4-12 Nominal size 12 Unit series 2X Nominal pressure 350 bar (pump side) Nominal pressure 420
More informationVickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93
Vickers Check Valves Check Valves Inline, right angle, manifold mounted, and pilot operated designs Released 9/93 645 Introduction Vickers inline, right-angle, and manifold mounted check valves are direct
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
More information4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)
4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) Type 4WRPEH 6 Size (NG) 6 Unit series 2X Maximum working pressure
More information820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.
SIT Group 820 NOVA mv MULTIFUNCTIONAL CONTROL FOR GAS THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE PIN 3AP700/2 SINGLE-KNOB MULTIFUNCTIONAL
More informationPILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V
PILOT OPERTED PRESSURE RELIEF VLVE - Series VR4V The Veljan Pressure Relief Valve series VR4V are pilot operated and wk Internal Dra on the prciple of hydraulic balancg. These valves are used to limit
More informationVSO MAX HP High Flow Proportional Valve
VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties
More information4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationPressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations
VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................
More information97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual
More informationHydraulic Flow Control Valves
Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series
More informationFluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
More informationDirect Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40
Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane
More information15/40/80CN Series Medium Pressure Filters
1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)
More information4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationVariable Displacement Pump AA10VSO
Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi
More informationSITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents
English translation of German original Technical Information TI-P11 SITEMA PowerStroke Mould Closing Devices series FS drive system for powerful forces on a short stroke hydraulic actuation closing force
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More information2-way flow control valve Type 2FRM 6
RE /0.0 Replaces:.0 -way flow control valve Type FRM Nominal size Series X Maximum operating pressure bar ) Maximum flow L/min ) When used in conjunction with a rectifier plate up to 0 bar H//D /97 + H//D
More informationPressure relief valves Size 6
Pressure relief valves Size 6 direct controlled Interface to DIN 24 340 and ISO 6264 PN [p max. ] = bar 750400.06.0.06 Description (standard units) Design The pressure relief valves of Type D B C 6 are
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationControl block EDD Modular Directional Valve
Control block EDD Modular Directional Valve 2 Control block EDD Modular Directional Valve Bosch Rexroth Oil Control S.p.A. introduces this innovatory Directional Control Valve size 8 which allows to create
More informationCatalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI KSWA3... SW-3... Ball sert Type...9./2.... 42/6... 3 K2A... 3Z... Poppet sert Type...38/1... 3/... 4 CS41B... C4-3...
More informationtype V46, solenoid or pneumatic operated
SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function
More information5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm
More informationValves. Sub-Base Mounted Valves to ISO 5599/2
Valves Sub-Base Mounted Valves to ISO 5599/2 General Information ISO 1, ISO 2 and ISO 3 valve series incorporate the famous Numatics lapped spool and sleeve for ultimate service life. Due to the great
More information0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3
Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00
More informationSCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.
SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of
More informationSolenoid Operated Directional Valves
INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SF-2C-115A-35 S-1AY-12D-35 SD-2C-12D-35 Features High Flow/ High Pressure: Up to 40 gpm / 5000 psi working pressure*.
More informationSOLENOID VALVES AND PNEUMATIC VALVES
2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the
More informationSolenoid valves Type EVU
Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot
More informationSolenoid Operated Directional Valves
INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SD-2B-115A-35 SDS-2H-12D-35 S-2B-115A-35 Features High Flow/ High Pressure: Up to 25 gpm / 5000 psi working
More informationARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP
ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP ARI-DP30 Pneumatic actuator Page 2 ARI-DP32 ARI-DP33 Pneumatic actuator DP-Actuator Extended stem
More informationLine rupture protection valves type LB
Line rupture protection valves type LB Pressure p max Flow rate Q A max = 500 bar = 4... 160 lpm Screw-in versions Type LB...C In-line versions Type LB...G Type LB...F 1. General Line rupture protection
More informationVP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
More informationPosition Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
More informationElectro-hydraulic pressure switches type DG
Electro-hydraulic pressure switches type DG Pressure p max = 700 bar See also: For electronic pressure switches type DG 5 E see D 5440 E Analogous pressure transducer type DT 1 see D 5440 T Analogous pressure
More informationKA/8000/M, KA/8000, ISO cylinder (Stainless steel) Magnetic & Non-magnetic piston, double acting
K/8000/M, K/8000, ISO cylinder (Stainless steel) > > Ø 3... 00 mm > > High corrosion and acid resistance > > Ideal for applications in the food industry > > Conforms to DIN ISO 555, DIN ISO 63, VDM 56
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationFlow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US
Catalog HY15-352/US Contents Control SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI NEED VALVES J2A2... C8-2... Needle Valve, Cartridge Type...45/12... 42/6... 5-6 NVH81... C8-2... Needle
More informationAxial Piston Variable Motor A6VM
Electric Drives and Controls Hydraulics Linear otion and ssembly Technologies Pneumatics Service xial Piston Variable otor 6V RE 91 604/05.06 1/76 Replaces: 06.03 Technical data sheet Series 6 Sizes Nominal
More informationLinear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors
20000 Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors 23000 22000 21000 20000 09000 08000 07000 06000 05000 04000 03000 02000 01000 823 Notes 824 Technical
More informationDirectional seated valves type VP 1
Directional seated valves type VP 1 zero leakage, intended for general hydraulic applications and grease lubing systems Flow Q max Operation pressure p max = 15 lpm = 400 bar Individual valve Individual
More information2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More informationFixed displacement vane pumps
Fixed displacement vane pumps RE 1335/1.5 Replaces: 11.2 1/22 Types PVV and PVQ Nominal sizes 18 to 193 Series 1X Maximum operating pressure 21 bar Maximum displacement 18 to 193 cm 3 Doppelpumpe_d_ Double
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationRotary actuators Rotary wing drives Series RAK. Brochure
Brochure 2 Rotary wing drives, angle of rotation: 30-270 Rotary wing drive, double-acting axis geometry: single 4 Rotary wing drives, angle of rotation: 90-270 Rotary wing drive, double-acting axis geometry:
More informationSpecifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.
Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical
More informationGoTo Europe Focused Delivery Program. Product Overview Hydraulics
GoTo Europe Focused Delivery Program Product Overview Hydraulics 2 GoTo Europe The products I need when I need them In today s global competition every day counts. Fast response times have become an important
More information