Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Size: px
Start display at page:

Download "Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100."

Transcription

1 Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa / to MPa. to MPa /4 55. to.8 MPa. to MPa. to MPa /4, /8, / 55. to.8 MPa. to.8 MPa /4 55. to.8 MPa /4, /8, / 55 AR45 to 95 V VEX ARX VY AP 549

2 Precision Regulator Series // and pressure gauge can be mounted from directions Mounting is possible on either the front or the back. Expanded regulating pressure range The maximum set pressure has been expanded from the conventional MPa to.8 MPa. Compact and lightweight width 5 mm mass 4 g width 5 mm mass g width 66 mm mass 64 g Manifolding is possible 8 stations at the maximum Made to order specifications (Except Series, ) OUT OUT OUT OUT OUT 55

3 Compatible with new modular connection brackets (-X) Can be combined with AF (Air filter) and AFM (Mist separator). Mount the standard type with a conventional connection bracket. Relief flow characteristics Possible to relieve (exhaust) air ranged 5 to 4 l/min (ANR) Back pressure: MPa Relief flow (l/min (ANR)) Series Variations Specifications Maximum set pressure. Model Basic type Air operated type MPa MPa.8 MPa Rc /8 Rc /4 Rc /8 Rc / Attachments such as a pressure switch can be mounted as accessories Applicable modular size : type : type : 4 type 5 4 Symbol T -L -X -X465 M 4 Relief flow (l/min (ANR)) Made to Order Specifications For details, refer to page 56. Back pressure: MPa. Specifications/Content Clean Series Copper-free and fluorine-free Ozone resistant For high temperature For low temperature Non-grease specifications With digital pressure switch (ISE) Manifold (Except Series, ) AR45 to 95 V VEX ARX VY AP 55

4 Series // Application Example Constant fluid pressure TANK Balance and drive Accurate balance pressure setting Since there is a large effective area for supply and exhaust pressure, setting can be done uickly. Limits pressure fluctuation when driving a cylinder, maintaining excellent static and dynamic balance. Accurate pressure setting Sensitivity within % F.S. (Full Span) Tension control Contact pressure control Winding roller Drive roller Low friction cylinder Adapts to the cylinder's piston displacement, maintaining a constant pressure. Multistage control of pressing force for workpiece (Wrapping machine) Leak test circuit Measured object Low friction cylinder 55

5 Precision Regulator RoHS Series // Basic type JIS Symbol Air operated type Standard Specifications Model Max. supply pressure Min. supply pressure () Regulating pressure range Input signal pressure Sensitivity Repeatability Linearity () Air consumption (4) (At supply pressure of. MPa) () Pressure gauge port :.5 to MPa :. to MPa :. to.8 MPa Rc /8 Set pressure +.5 MPa Basic type :.5 to MPa :. to MPa :. to.8 MPa Rc /4 Max.. MPa Set pressure +. MPa :. to MPa :. to MPa :. to.8 MPa Within % of full span Within ±% of full span 4.4 l/min (ANR) or less 4.4 l/min (ANR) or less.5 l/min (ANR) or less 4.4 l/min (ANR) or less Rc /4, /8, / Rc /8 ( locations) Ambient and fluid temperature 5 to 6 C (No freezing) Mass (kg) 4 5 Note ) With the condition of no flow on the output side. Together with the set pressure, be sure to maintain a minimum differntial pressure of.5 MPa for models and, and. MPa for model. Note ) Applicable only to air operated types and. The basic type is excepted. Note ) Indicates the linearity of the output pressure with respect to the input signal pressure. Note 4) Air is normally being discharged to the atmosphere from a bleed hole or an exhaust port. Body size Precision regulator Type of setting Basic type (Handle) Air operated type (Series / only) Regulating pressure range For series /.5 to MPa. to MPa. to.8 MPa Note) Air operated type is model only. For series. to MPa. to MPa. to.8 MPa Note) Air operated type is model only. How to Order Symbol size 4 Thread type Nil Rc N NPT F G Option /8 /4 /8 / Application Air operated type Set pressure +.5 MPa. to.8 MPa. to.8 MPa Rc /4 Within ±% of full span R Set pressure +. MPa. to.8 MPa. to.8 MPa.5 l/min (ANR) or less Rc /4, /8, / Suffix Nil For high temp. enviroments ( 5 to C) T (Max. 8 C with pressure gauge.) L For low temp. enviroments ( to 6 C) Suffix Nil Accessory Nil B G None With bracket With pressure gauge Note) Pressure gauge,, Name plate, Mounting on the opposite side Note) The standard mounting position of the pressure gauge is on the front, when viewing the regulator with the SUP side to the left and OUT side to the right. Pressure gauge is included, (but not assembled). Made to Order Specifications (Refer to page 56) Symbol Specifications/Content X Non-grease specifications X Compatible with modular connection brackets(refer to page 554) X465 With digital pressure switch (ISEA) Add prefix (-) for the clean room specification. Add prefix (-) for the copper-free and fluorine-free specification. Add prefix (8-) for the ozone-resistant specification. 4 Manifold specification is available for and. (Except and ) 55 AR45 to 95 V VEX ARX VY AP

6 OUT OUT G EXH OUT G G Series // Series Series Series Specification Combinations Standard specifications Accessory Option Specifications : Standard specifications : Combination possible : Combination not possible Applicable model Set pressure Max. MPa Set pressure Max. MPa Set pressure Max..8 MPa Connection Rc /8 Connection Rc /4 Connection Rc /8 Connection Rc / Pressure gauge Pressure gauge reverse mounted Connection NPT /8 Connection NPT /4 Connection NPT /8 Connection NPT / Connection G /8 Connection G /4 Connection G /8 Connection G / Symbol 4 B G R N N N N4 F F F F4 <Combination example> einterface rinterface with bracket Modular and Accessory Combinations Description. Air filter. Mist separator. Interface 4. Interface with bracket --X AF AFM Y YT Applicable model --X AF AFM Y YT --X AF4 AFM4 Y4 Y4T Note ) Use the made-to-order product (-X) for modular connections. The interface and interface with bracket listed above cannot be connected to the standard type. Use a conventional connection interface when connecting the standard type with modular connections. Note ) The made-to-order product number (-X) is for the precision regulator only. For modular connections, please order the applicable products and accessories separately. wafm AF --X AF wafm --X 4 AF4 wafm4 5 Accessory /Part No. --X Description Part no. / / Pressure gauge G-- P6 G-4- G-- G4-- P68 G4-4- G4-- G4-- P6- G4-4- G4-- A bracket and two mounting screws (M5 x 5) To mount the bracket, remove two body screws (M5 x ) on the name plate on the opposite side and replace the attached two bracket mounting screws (M5 x 5). Accuracy ±% (Full span) 554

7 Precision Regulator Series // Construction Replacement Parts No. Description Material i!5 SUP side SUP() u Valve guide Exhaust Diaphragm assembly Diaphragm assembly Diaphragm Valve Valve Valve Damper O-ring O-ring O-ring O-ring O-ring Seal (A) Seal (B) Fixed throttle OUT side w OUT() r! Working principle (For ) When the setting knob is turned, the nozzle is closed by the flapper allowing the supply air that flows in from the upstream side to pass through the fixed throttle. It then acts on diaphragm B as nozzle back pressure, the main valve is pushed down by the generated force, and the supply pressure flows out to the downstream side. The air pressure that flows in acts on diaphragm C. While opposing the force generated by diaphragm B it also acts on diaphragm A, opposing the compression force of the setting spring and becomes the set pressure. If the set pressure rises too high, diaphragm A is pushed up, the interval between the flapper and the nozzle widens, the nozzle back pressure drops, the balance of diaphragms B and C is broken, the main valve closes, the exhaust valve opens and the excess pressure from the downstream side is discharged to the atmosphere. In this way fine pressure variations are detected by the nozzle/flapper type pilot mechanism, and precise pressure adjustment is performed. i i NBR, other NBR, other NBR, other Stainless steel, NBR Brass, NBR Brass, NBR NBR, other H-NBR NBR NBR NBR NBR NBR NBR Stainless steel Repair kit no. (A set of above nos. to!5.)!5fixed throttle!5 SUP side e w r u! SUP() e w u! Part no. Qty. Part no. Qty. Part no. Qty. Part no. Qty. Part no. Qty. P6- P6- P658 P6 ø.5 x.5 ø x. P68 i Valve guide SUP side SUP() i Valve guide P6- P6-5 P69 P668# P66 ø.4 x.5 ø4.5 x JISB4P P68 o o OUT side Setting knob Diaphragm (A) Steel ball Nozzle Diaphragm (B) Exhaust Diaphragm (C) OUT() Exhaust Valve Main valve OUT side IN OUT() o o P6- P6- P69# P6# ø4.5 x ø7.8 x.5 JISB4P5 Note) JISB4P6 Note) P65 P66 P67!5!5 SUP side!!! SUP()!! Valve guide SUP side!!! SUP()!! Valve guide!4!4 P6- P6-5 P69 P668# P66 ø.4 x.5 ø4.5 x JISB4P P68 OUT side w y OUT() t OUT side IN w y OUT() t o o P6- P6- P69# P6# ø4.5 x ø7.8 x.5 JISB4P5 Note) JISB4P6 Note) P65 P66 P67 KT- KT- KT- KT- KT- AR45 to 95 V VEX ARX VY AP Note) Use mini-flick type. 555

8 OUT Series // Dimensions SUP() EXH ø8.5 x Rc /8 Pressure gauge port Mounting hole Pressure gauge OUT() Panel mounting hole Max.4 ø Panel When mounting on a panel, refer to page 56 in Specific Product Precautions. ø M5 x P x Rc /8 SUP() 5 Mounting hole ø9.5 ø.5 Panel mounting hole Pressure gauge Panel When mounting on a panel, refer to page 56 in Specific Product Precautions. OUT() ø4 x Rc /8 Pressure gauge port Max.4 M6 x P Exhaust x Rc / Mounting hole Panel mounting hole Max.4 ø.5 Pressure gauge Panel When mounting on a panel, refer to page 56 in Specific Product Precautions. - SUP() ø9.5 Mounting hole Pressure gauge IN OUT() ø4 x Rc /8 Pressure gauge port M5 depth 7 Exhaust x Rc /4 SUP() 9 ø5.5 OUT() ø4 M6 x P 76 EXH() Mounting hole Pressure gauge x Rc /8 Pressure gauge port 66 Rc / Exhaust port x Rc /4 to / SUP() 66 9 ø5.5 IN OUT() M5 depth 7 ø x Rc /8 Pressure gauge port EXH() Rc / Exhaust port x Rc /4 to /

9 Precision Regulator Series // Series Flow Characteristics Testing methods conform to JIS B 87. Relief Characteristics - Supply pressure: MPa - Back pressure: MPa - Pressure Characteristics Supply pressure: MPa Set pressure: MPa Flow rate: l/min (ANR) Supply pressure: MPa - Back pressure: MPa Supply pressure:. MPa - Back pressure:. MPa Set pressure P (MPa) Set pressure P (MPa) Set pressure P (MPa) Supply pressure P (MPa)..8.9 Supply pressure P (MPa)..8.9 Supply pressure P (MPa)... AR45 to 95 V VEX ARX VY AP 557

10 Series // Series Flow Characteristics Testing methods conform to JIS B 87. Relief Characteristics - Supply pressure: MPa - Back pressure: MPa - Pressure Characteristics Supply pressure: MPa Set pressure: MPa Flow rate: l/min (ANR) Set pressure P (MPa) Supply pressure P (MPa) - Supply pressure: MPa - Back pressure: MPa -. Set pressure P (MPa) Supply pressure P (MPa) - Supply pressure:. MPa - Back pressure:. MPa Set pressure P (MPa) Supply pressure P (MPa). - Supply pressure:. MPa - Back pressure:. MPa Set pressure P (MPa) Supply pressure P (MPa). 558

11 Precision Regulator Series // Series Flow Characteristics Testing methods conform to JIS B 87. Relief Characteristics - Supply pressure: MPa - Back pressure: MPa - Pressure Characteristics Supply pressure: MPa Set pressure: MPa Flow rate: l/min (ANR) Supply pressure: MPa - Back pressure: MPa Supply pressure:. MPa - Back pressure:. MPa Supply pressure:. MPa - Back pressure:. MPa Set pressure P (MPa) Set pressure P (MPa) Set pressure P (MPa) Set pressure P (MPa) Supply pressure P (MPa)..8.9 Supply pressure P (MPa)..8.9 Supply pressure P (MPa)... AR45 to 95 V VEX ARX VY AP Supply pressure P (MPa) 559

12 OUT OUT OUT OUT OUT Series // Made to Order Specifications: Please contact SMC regarding detailed dimensions, specifications, and delivery times. Clean Series Standard model no. Note) Please contact SMC if a product with pressure gauge is desired. Clean Series Specifications Cleanliness hole EXH port Grease Class With M5 fitting (Applicable tubing O.D. ø6) /: With M5 fitting (Applicable tubing O.D. ø6) : Rc / female thread Teflon grease External and internal copper parts are changed to stainless steel or aluminum. 4 Copper-free and Fluorine-free Standard model no. Note) Please contact SMC if a product with pressure gauge is desired. Copper-free and Fluorine-free Fluoro rubber is used for rubber seal materials. 8 Ozone Resistant Standard model no. For High/Low Temperature Environments Standard model no. Specifications Symbol Environment Ambient temperature Rubber material 5 Ozone resistant T For high/low temperature environments T L T For high temp. environments 5 to C (Max. 8 C with pressure gauge) Fluoro rubber Non-grease Specifications For high temperature For low temperature L For low temp. environments to 6 C Special NBR Assembly is performed in an ordinary environment without using grease. However, since parts are not washed, they are not completely oil-free. Standard model no. 56 X Non-grease specifications 6 With digital pressure switch (model no: ISEA---ML). Mount a digital pressure switch into the connection port for pressure gauge, as it is not mounted at the time of shipment. Specifications Made to order part no. Pressure switch 7 Manifold Specifications (Except type and series ) to 8 station manifold type regulators. (Please contact SMC regarding 9 or more stations.) M G Manifold type regulator Specifications Stations Port With Digital Pressure Switch Set pressure range (MPa) Desolution of setting and display (MPa) Current consumption How to Order 8 Body size Set pressure Power supply voltage Standard model no. Note) Note) Except for symbol G Note ) Please contact SMC separately for details about the external dimensions, etc. Note ) For details on handling digital pressure switch and specifications, refer to the catalog (CAT.E-7): Series ISEA. Note ) Digital pressure switch is packed togther. Accessory (Pressure gauge) Set pressure and uantity MPa setting to n pcs. MPa setting to n pcs..8 MPa setting to n pcs. Example ) MPa setting with 6 stations M-6G-6 Example ) MPa setting pcs., MPa setting pcs.,.8 MPa setting pc. with 5 stations M-5G- Accessory (Pressure gauge) stations Nil None : G-- 8 stations G : G4-- Accessory (pressure gauge) is included, (but not assembled). Thread type (Thread on the manifold base) Stations Nil N F X465. to. to 4 VDC ±%, Ripple (p-p) % or less (With reverse connection protection) 4 ma or less X465 A With digital pressure switch Switch specifications Symbol A B C D Rc NPT G Output specifications NPN open collector output PNP open collector output NPN open collector output + Analog voltage output NPN open collector output + Analog current output to 8 stations Common SUP : /4, : / Individual OUT : /8, : /4 Individual EXH (From body) MPa, MPa and.8 MPa settings can be combined. G-- (), G4-- () Note ) Regulators to be manifolded are counted starting from stations on the left side with the OUT ports in front. Note ) When regulators with a different set pressure are manifolded, viewing OUT ports from front, the low pressure range is installed on the left side and high pressure range is on the right side. In case of the Example ) above mentioned, stations and are of MPa setting, stations and 4 are of MPa setting, and station 5 is of.8 MPa setting. Note ) Please consult with SMC when a blanking plate is needed.

13 Series // Specific Product Precautions Be sure to read before handling. Refer to front matters 4 and 4 for Safety Precautions and pages 87 to 9 for Precautions on every series. Warning Caution Warning Warning Caution Air Supply. If the drain removal from air filter and mist separator is missed, drain will be flown out to the outlet side and may result in a malfunction of the pneumatic euipment. When removing drain is difficult, use of a filter with an autodrain is recommended.. If the supply pressure line contains drain or particlate, etc., the fixed throttle can become clogged leading to malfunction, and therefore, in addition to an air filter (SMC Series AF) be sure to use a mist separator (SMC Series AM, AFM). Refer to pages and regarding air uality.. Never use a lubricator on the supply side of the regulator, as this will positively cause the fixed throttle to become clogged and result in a malfunction. If lubrication is reuired for terminal devices, connect a lubricator on the output side of the regulator. Maintenance. When the valve guide (refer to construction drawing on page 555) is to be removed during maintenance, first reduce the set pressure to and completely shut off the supply pressure.. When a pressure gauge is to be mounted, remove the plug after reducing the set pressure to. Precautions for only. When remounting the valve guide after removing it for maintenance, use a tightening torue of no more than N m. Since the valve guide on this product is made of resin, there is a danger of damage if tightened with a torue exceeding the prescribed value. Handling. Do not apply force when transferring, mounting and dropping the regulator with a pressure gauge. This may cause misalignment of the pressure gauge pointer. Caution Caution Operation. Do not use a precision regulator outside the range of its specifications as this can cause failure. (Refer to specifications.). When mounting is performed, make connections while confirming port indications.. Screw a panel nut with the recommended proper torue when mounting onto a panel. Looseness or faulty sealing will occur if tightening torue is insufficient, while thread damage will result if the torue is excessive. Recommended Proper Torue (N m).5 4. If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side. In the event a directional switching valve will be used, install it on the output side of the regulator. 5. Air is normally released from the bleed hole (the hole on the side of the body s mid-section). This is a necessary consumption of air based on the construction of the precision regulator, and is not an abnormality. 6. Make sure to tighten the lock nut after pressure adjustment. Precautions for, only. The supply pressure is relatively high (approx. MPa or more), the set pressure is low (approx.. MPa or less), and when operated with the output side released to the atmosphere, there may be pulsations in the setting pressure. In this kind of situation, operate with the supply pressure reduced as much as possible, or increase the set pressure somewhat and restrict the output line (add and adjust a stop valve, etc.).. The capacity of the output side is large, and when used for the purpose of a relief function, the exhaust sound will be loud when being relieved. Therefore, operate with a silencer (SMC Series AN) mounted on the exhaust port (EXH port). The connection is Rc /. Precautions for, (air operated type) only Caution. Since the output types of and are the same pressure as the input signal pressure, select a type of regulator (general purpose or precision type) for input signal pressure adjustment according to the application.. The screw on the topmost section is a zero point adjustment screw which is locked at the factory and reuires no adjustment for operation. AR45 to 95 V VEX ARX VY AP 56

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

AIR-AIR PRESSURE MULTIPLIER (BOOSTER) AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally

More information

CAT.ES120-4 A. Precision Clean Regulator. Series SRP. High precision, low flow consumption stainless steel regulator

CAT.ES120-4 A. Precision Clean Regulator. Series SRP. High precision, low flow consumption stainless steel regulator CAT.ES120-4 A Precision Clean Regulator Series SRP High precision, low flow consumption stainless steel regulator Precision Clean Regulator Series SRP High precision, low flow consumption stainless steel

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Model 43AP Pneumatic Controller, Style B

Model 43AP Pneumatic Controller, Style B Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set

More information

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications Speed Controller with One-touch Fitting Stainless Steel Series Elbow Type/Universal Type Series -FG RoHS Stainless specifications for use in corrosive environments. Stainless steel used for metal parts.

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

Self Purging Liquid Trap (SPLT ) User s Manual

Self Purging Liquid Trap (SPLT ) User s Manual Self Purging Liquid Trap (SPLT ) User s Manual High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High

More information

G1/4 Q8. Standard with biased position

G1/4 Q8. Standard with biased position Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

T-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5. www.thomsonlinear.com

T-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5. www.thomsonlinear.com T-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5 www.thomsonlinear.com Version History Edition Number Edition Date Reason for Revision 1 2004 First edition

More information

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00

More information

Valve systems Base plates, according to standard ISO 5599-1. Brochure

Valve systems Base plates, according to standard ISO 5599-1. Brochure ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure

More information

Typical Aluminum GFM Mass Flow Meter

Typical Aluminum GFM Mass Flow Meter MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9 Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

BERMAD Fire Protection

BERMAD Fire Protection 400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 400E-2M/700E-2M Bermad

More information

3/2-way pneumatic cartridge solenoid valve

3/2-way pneumatic cartridge solenoid valve 3/2-way pneumatic cartridge solenoid valve Compact design with 11 mm width per station Orifices from 0.5 mm (9 bar) to 1.2 mm (1.5 bar) High durability and reliability Low power consumption, as well as

More information

TECHNICAL DATA. Dry 122a. November 12, 2013

TECHNICAL DATA. Dry 122a. November 12, 2013 Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model

More information

IMPORTANT DOCUMENTATION DO NOT DISCARD!

IMPORTANT DOCUMENTATION DO NOT DISCARD! PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

AUTOMATIC CHANGEOVER MANIFOLD Series 915

AUTOMATIC CHANGEOVER MANIFOLD Series 915 AUTOMATIC CHANGEOVER MANIFOLD Series 915 FEATURES Fully automatic, simple, hassle-free operation No variance in delivery pressure Designed for ultra high purity gas service Built-in audio and visual alarm

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Shut-off & Lockout Valves 1/4 to 1-1/2 port size Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8 * U S 4 Specifications escriptions Bore size mm Actuation Working fluid ax. working pressure Pa in. working pressure Pa Withstanding pressure Pa Ambient temperature Port size Stroke length Rubber cushioned

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve Series VN Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering Model: 400E-2M Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Application Engineering BERMAD 1. Safety First BERMAD believes that the safety

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Model position position Type of actuation

More information

Electro-Pneumatic Bus Door Control Mechanism

Electro-Pneumatic Bus Door Control Mechanism Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

BERMAD Fire Protection

BERMAD Fire Protection Model: 400E-2M BERMAD Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Safety First BERMAD believes that the safety of personnel working with and around

More information

Operating instructions Mechatronic flow sensor. SBY33x 704465/06 03/2011

Operating instructions Mechatronic flow sensor. SBY33x 704465/06 03/2011 Operating instructions Mechatronic flow sensor SBY33x 7065/06 03/2011 Contents 1 Safety instructions...2 2 Functions and features...3 3 Installation...3 Electrical connection... 5 Switch point setting...

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

POWERS CONTROL RC 195 Single Input Receiver-Controller

POWERS CONTROL RC 195 Single Input Receiver-Controller Document No. 155-119P25 RC 195-4 POWERS CONTROL RC 195 Single Input Receiver-Controller Description The RC 195 Single lnput Receiver-Controller is a pneumatic instrument which receives one pneumatic input,

More information

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................

More information

type V46, solenoid or pneumatic operated

type V46, solenoid or pneumatic operated SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

167D Series Switching Valves

167D Series Switching Valves June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are

More information

Compressor Service & Maintenance Manual

Compressor Service & Maintenance Manual Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double 4/ Port Solenoid Valve Rubber Seal VZ1000/000/000 Solenoid Valve Variations Port Size Effective area (mm 2 ) Position solenoid Voltage Electrical entry Option/ Indicator light and surge voltage suppressor

More information

Hydraulic Trouble Shooting

Hydraulic Trouble Shooting Hydraulic Trouble Shooting Hydraulic systems can be very simple, such as a hand pump pumping up a small hydraulic jack, or very complex, with several pumps, complex valving, accumulators, and many cylinders

More information

On-off valves MS-EM/EE, MS series, NPT

On-off valves MS-EM/EE, MS series, NPT On-off valves MS-EM/EE, MS series, NPT On-off valves MS9-EM, MS series, NPT Peripherals overview 5 3 4 aa -H- Note Additional accessories: Module connector for combinations with size MS6, MS9 or size MS12

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

Control block VOFA with safety function

Control block VOFA with safety function Key features Innovative Versatile Reliable Easy to assemble Can be used for safe reversing of a hazardous movement (5/2-way solenoid valve) Can be used for safe venting (3/2-way solenoid valve function,

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)

More information

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents English translation of German original Technical Information TI-P11 SITEMA PowerStroke Mould Closing Devices series FS drive system for powerful forces on a short stroke hydraulic actuation closing force

More information

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop

More information

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP Feb 5, 2003 1 CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING COMPLETE SYSTEM CHECK - PNEUMATIC PUMP THE SYSTEM DOES

More information

Graymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions

Graymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions 795 08690 GM 12 00 Graymills Air Operated Double Diaphragm Pumps Operations and Maintenance Instructions /S Read all these SAFETY INSTRUCTIONS BEFORE installing or using this equipment. Keep this manual

More information

Booster Regulator/Air Tank

Booster Regulator/Air Tank Booster Regulator/Air Tank Series /T Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. Renewed

More information

COUNTERBALANCE VALVES

COUNTERBALANCE VALVES COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load

More information

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

3, 4, 6 & 8 Model H Series Alarm Check Valve Installation and Maintenance Guide ", ", " & " Model H Series Alarm Check Valve Installation and Maintenance Guide 077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE 99-- 00-2-0 FAX 99--92 www.globesprinkler.com OCTOBER 2 C- BULLETIN A.C.V.I.M.,

More information

Wear Resistant Tubing

Wear Resistant Tubing Wear Resistant Tubing 1/ brasion: pprox. (Compared with SMC polyurethane tubing TU series) 3 6-color variations Description Wear resistant tubing TUZ series Polyurethane tubing TU series Green RoHS Maximum

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY

More information

Control blocks for two-hand start ZSB

Control blocks for two-hand start ZSB Key features Function This pneumatic control block for twohand start ZSB is used where a manually started operation, such as the triggering of compressed air cylinders, would otherwise involve danger for

More information

BOWIE PUMPS OPERATION - MAINTENANCE

BOWIE PUMPS OPERATION - MAINTENANCE BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped

More information

Valves. Sub-Base Mounted Valves to ISO 5599/2

Valves. Sub-Base Mounted Valves to ISO 5599/2 Valves Sub-Base Mounted Valves to ISO 5599/2 General Information ISO 1, ISO 2 and ISO 3 valve series incorporate the famous Numatics lapped spool and sleeve for ultimate service life. Due to the great

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

CG-1171-20 PTFE Diaphragm Liquid Transfer Pump

CG-1171-20 PTFE Diaphragm Liquid Transfer Pump 3800 N. Mill Road Vineland, NJ 08360 Phone: 800.843.1794 Fax: 800.922.4361 CG-1171-20 PTFE Diaphragm Liquid Transfer Pump This is the safety alert symbol. It is used to alert you to potential personal

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils

More information

MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK

MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK 1 565AKHU HYDRAULIC 1.22 O-RING - 2 REQUIRED UNIT 1.23 O-RING COMPLETE 1.24 TEFLON O-RING 2 REQUIRED 1.3 EXTENSION SCREW 1.3A SPRING PIN 1.4 SPRING SUPPORT 1.5 SCREW BUSHING 1.6 Y SHAPE SEAL RING 1.7 HEAD

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,

More information

MODEL G300 BRAKE BLEEDER

MODEL G300 BRAKE BLEEDER MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY

More information

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 gpm@gpmhydraulic.com www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS

More information

HYDRAULIC LIFT TABLE CART 2200-LB.

HYDRAULIC LIFT TABLE CART 2200-LB. HYDRAULIC LIFT TABLE CART 2200-LB. OWNER S MANUAL WARNING: Read carefully and understand all MACHINE ADJUSTMENT AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other

More information

Model 41 Nullmatic Pressure Regulators

Model 41 Nullmatic Pressure Regulators Siemens Industry, Inc. INSTALLATION AND SERVICE INSTRUCTION SD41 Rev 13 June 2012 Supersedes Rev 12 Model 41 Nullmatic Pressure Regulators INTRODUCTION The Model 41 Nullmatic Pressure Regulator, shown

More information

Series 30000 Hose Reels

Series 30000 Hose Reels Operating Instructions and Parts List for Series 30000 Hose Reels - MANUAL DRIVEN - - POWER DRIVEN - SAFETY PRECAUTIONS Personal injury and/or equipment damage may result if proper safety precautions are

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Many Products...One Source

Many Products...One Source PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K

More information

GROENEVELD AUTOMATIC GREASING SYSTEMS

GROENEVELD AUTOMATIC GREASING SYSTEMS GROENEVELD AUTOMATIC GREASING SYSTEMS TWIN Parts & Accessories Book Pumps, Fittings, Injectors, Lining, etc. www.groeneveld-group.com 1 TWIN ELECTRICAL Item Part # Description 1 F113966 Switch 24V 2 F122991

More information