1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

Size: px
Start display at page:

Download "1.8 w 101.2. 3 Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption"

Transcription

1 Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A single valve with various valve functions (Universal porting type) N.C. valve Divider valve N.O. valve Selector valve etc Low concentration ozone resistant Rubber seal material: HNBR for main valve Mounting dimensions are interchangeable with existing product 9.5. Body ported type Manifold type Series VT07 CAT.ES-07A

2 Series VT07 Port Solenoid Valve Direct Operated Poppet Type A variety of valve options Continuous duty type Vacuum specification type Energy-saving type Energy-saving type + Vacuum specification type Application examples q Blow-off valve w Pressure release valve e Selector valve r Valve for vacuum (P) (R) (A) (P) (R) X Plug (A) P P (P) (R) (A) Vacuum pump (P) (R) (A) Vacuum pad Vacuum releasing air Atmospheric pressure or micro pressure t Divider valve y Single-acting cylinder drive u Double-acting cylinder drive i Double-acting cylinder drive (Exhaust center) Tank (P) (R) Tank (A) (P) (R) (A) N.C. (A) (P) (R) (P) N.O. (A) (R) N.C. (A) (P) (R) (P) N.C. (A) (R) Port Solenoid Valve, Universal Porting Type Variations Poppet type Direct operated poppet type Pilot poppet type Series New VT07 VT7 VT5 VP00/500/700 Cv (P A) to.6 Refer to the SMC website for details. Features

3 Port Solenoid Valve Direct Operated Poppet Type Series VT07 Rubber Seal RoHS [Option] Note) CE compliant: Electrical entry is applicable only for the DIN terminal. How to Order V T 07 5 G 0 F T O Body type Body ported For manifold Valve option Nil Standard type E Continuous duty type Y Energy-saving type V Vacuum specification type W Energy-saving type, Vacuum specification type Semi-standard Pressure specifications Nil Standard type (0.7 MPa) K High-pressure type ( MPa) Semi-standard Grommet Rated voltage 00 VAC, 50/60 Hz 00 VAC, 50/60 Hz 0 VAC, 50/60 Hz 4 0 VAC, 50/60 Hz 5 4 V 6 V 7 40 VAC, 50/60 Hz Semi-standard Electrical entry DIN terminal Thread type Nil Rc F G N NPT T NPTF CE-compliant Nil None Q CE-compliant Electrical entry and light/surge voltage suppressor: D/DO/DZ/DOZ only Bracket Nil None F With bracket Port size Nil Without port (For manifold) 0 /8 (6A) 0 /4 (8A) Light/Surge voltage suppressor Nil None With surge voltage suppressor S (Grommet type only) With light/surge voltage suppressor Z (DIN terminal type only) With surge voltage suppressor Surge voltage suppressor G: 00 mm lead wire H: 600 mm lead wire D: With connector JIS Symbol (A) (R) (P) DO: Without connector Manifold Model Applicable manifold type Accessories Function plate (DXT5-4-A) VO07 (-Q) Common or individual exhaust Note) Mounting screw (NXT0-) Note) It is not applicable to the continuous duty type. Refer to the accessories on page 5. Option Description Bracket Part no. DXT5-5-A (With screw)

4 Series VT07 Standard Specifications Make sure that dust and/or other foreign materials do not enter the valve from the unused port (e.g. exhaust port). Flow-rate Characteristics/Weight Type of actuation Fluid Operating pressure range Ambient and fluid temperature Response time Note ) Max. operating frequency Lubrication Mounting orientation Impact/Vibration resistance Note ) Enclosure Electrical entry rated voltage (V) Allowable voltage fluctuation Note ) Note 4) Apparent power AC Note ) Note 4) Power consumption Light/Surge voltage suppressor (DIN terminal type only) Direct operated type position single solenoid Air 0 to MPa (High-pressure type), 0 to 0.7 MPa (Standard type) 0 to 50 C (No freezing) 0 ms or less (at 0.5 MPa) 0 Hz Not required (Use turbine oil Class ISO VG, if lubricated.) Non-locking push type Unrestricted 50/50 m/s Dustproof AC (50/60 Hz) Inrush Holding AC Grommet, DIN terminal 00, 00, 0, 0, 40 4, 5 to +0% of rated voltage.7 VA (50 Hz), 0.7 VA (60 Hz) 7.6 VA (50 Hz), 5.4 VA (60 Hz) Without indicator light: 4 W, With indicator light: 4. W Varistor, LED Diode, LED Semi-standard Note ) Based on dynamic performance test, JIS B ( temperature: 0 C, at rated voltage, without surge voltage suppressor) Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) At rated voltage Note 4) The value is different for continuous duty type (VT07E), and energy-saving type (VT07Y/W). Refer to Valve Options shown below. Valve model Flow-rate characteristics Port (P A) (A R) (R A) (A P) size C[dm /(s bar)] b Cv C[dm /(s bar)] b Cv C[dm /(s bar)] b Cv C[dm /(s bar)] b Cv VT07 VT07V (Vacuum spec. type) VT07E (Continuous duty type) /8 VT07Y (Energy-saving type) VT07W (Energy-saving, Vacuum spec. type) VT07 VT07V (Vacuum spec. type) VT07E (Continuous duty type) /4 VT07Y (Energy-saving type) VT07W (Energy-saving, Vacuum spec. type) Note) Values for a single valve unit. It is not applicable to the manifold. Refer to the manifold specifications on page 5. Weight Grommet 0.5 kg Valve Options Continuous duty type: VT07E Exclusive use of VT07E is recommended for continuous duty with long time loading.. This model is for continuous duty, not for high cycle rates. But even in low cycle rates, if energizing the valve more than once a day, please consult with SMC.. Energizing solenoid should be done at least once in 0 days. Specifications different from standard are as follows. Apparent power/ Inrush 7.9 VA (50 Hz), 6. VA (60 Hz) AC Holding 5.8 VA (50 Hz),.5 VA (60 Hz) Power consumption/.8 W, With indicator light: W Response time Note) 0 ms or less (at 0.5 MPa) Note) Refer to Note ) of the standard specifications. Energy-saving type: VT07Y (VT07W) If low power consumption is required for electronic control, VT07Y(W) (.8 W) is recommended. Specifications different from standard are as follows. Power consumption/.8 W, With indicator light: W Response time Note) 5 ms or less (at 0.5 MPa) Note) Refer to Note ) of the standard specifications. Vacuum spec. type: VT07V (VT07W) This vacuum model has less air leakage than the standard model under low pressure. It is recommended for vacuum application. Since this valve has slight air leakage, it can not be used for vacuum holding (including positive pressure holding) in the pressure container. Specifications different from standard are as follows. Operating pressure range 0. kpa to 0. MPa

5 Port Solenoid Valve Direct Operated Poppet Type Series VT07 Construction De-energized r Energized t Light/Surge Voltage Suppressor AC In the case of indicator light assembly Terminal no. q r y u q Terminal no. In the case of indicator light assembly Terminal no. (+) (Å) w e (Â) Operation principle <De-energized> Poppet valve w is pushed upward by the return spring e, port is closed. Then, port and port are connected. Air flow direction: Port Block, Component Parts No. 4 Description Body Poppet valve Return spring Molded coil How to Use DIN Terminal. Disassembly ) After loosening the screw q, then if the housing w is pulled in the direction of the screw q, the connector will be removed from the body of equipment (solenoid, etc.). ) Pull the screw q out of the housing w. ) On the bottom part of the terminal block e, there s a cut-off part o. If a small flat head screwdriver is inserted between the opening in the bottom, terminal block e will be removed from the housing w. 4) Remove the cable gland r, plain washer t and rubber seal y.. Wiring ) Pass the cable u through the cable gland r, plain washer t and rubber seal y in this order, and then insert them into the housing w. ) Loosen the screw! attached to the terminal block e. Then, pass the lead wire!0 through the terminal block e and tighten the screw! again. Note ) Tighten within the tightening torque of 0.5 N m ±5%. Note ) Cable u outside diameter: ø6 to ø8 mm Note ) Crimped terminal like round-shape or Y-shape cannot be used. Connector for DIN Terminal Description DIN connector Part no. BB09-A (Standard) GM09NJ-B7 (CE-compliant) ( ) (Å) ( ) Material Aluminum die-casted Aluminum, HNBR Stainless steel Resin w e (Â) <Energized> When energizing the molded coil r, the armature t is magnetically attracted to the core y, and through the push rod u, it pushes down the poppet valve w and port is closed. Then, port and port are connected. At this time, there will be gaps between the armature t and the core y, but the armature t will be magnetically firmly attracted to the core y. Air flow direction: Port Port, Port Block Note Color: White. Assembly ) Pass the cable u through the cable gland r, plain washer t and rubber seal y in this order and connect to the terminal block e. Then, mount the terminal block e on the housing w. (Push it down until you hear the click sound.) ) Put the rubber seal y and plain washer t in this order into the cable entry of the housing w, and then tighten the cable gland r securely. ) Insert the gasket i between the bottom part of terminal block e and the plug attached to the equipment. Then, screw in q from the top of the housing w to tighten it. Note ) Tighten within the tightening torque of 0.5 N m ±0%. Note ) Connector orientation can be changed 80 depending on how the housing w and the terminal block e are assembled. e i q w o!!0 y t u r Terminal no. ( ) Electrical Connection DIN terminal is connected inside as in the figure below. Connect to the corresponding power supply. DIN terminal block Voltage 00 VAC 00 VAC Others Ground Applicable cable O.D. ø6 to ø8 Terminal no. DIN terminal Lead Wire Color + Color Blue Red Red (+), Black ( ) Gray

6 Series VT07 Dimensions Grommet: VT07- G x ø4.5 (For mounting) (4.5) (4.5) Note) There is also VT07- H (lead wire length: 600 mm). Applicable cable O.D. ø6 to ø8 (4) () (7.) x ø4.5 (For mounting) (4.5) (4.5) (8) (7) (4.5) Pg9 Max (4) () (7.) (4.5) (8) (7) G: 00 H: 600 (Lead wire length) (.) 6.5. /4", /8" (Piping port) M4 x 0.7 thread depth 7 (Mounting screw) 5 DIN terminal: VT07- D (.) 6.5. /4", /8" (Piping port) 4 M4 x 0.7 thread depth 7 (Mounting screw) 5

7 Series VT07 Manifold Specifications VT07 manifold is available both as a common exhaust and individual exhaust model. Manifold valve can be easily converted from N.C. (Normally Closed) to N.O. (Normally Open) merely by turning over the function plate. Common exhaust VV F Individual exhaust VV F VV07 VT07 manifold How to Order Manifold Base F Dummy symbol Valve stations 0 stations 0 0 stations Max. 0 stations Specify model number of the manifold base, applicable valves and blanking plates when ordering. Refer to page for the model number of the valves. Ordering example: VV F pc. (5 station manifolds base) VO07-G 4 pcs. DXT060-5-A pc. (Blanking plate) Manifold Specifications Manifold type Max. number of stations Applicable solenoid valve Exhaust port Symbol Type Common Individual P Base (Side) 8 Base (Side) A port size (Base mounted) common exhaust/individual exhaust 4 individual exhaust Exhaust port type Common exhaust Individual exhaust Mounting bracket Thread type Nil F N T Rc G NPT NPTF B mount 0 stations Note) VO07 - (-Q) Port location (Direction)/Port size A R Base (Side) Base (Side) 8 8 Base (Side) Base (Top) 4 8, 4 8 Note) For 6 stations or more, supply air both sides of P port. The common exhaust type should exhaust from both of the R port. Option Description Blanking plate (With gasket, screw) Note) Part no. DXT A B Accessories for Applicable Solenoid Valve Description Part no. Qty. Function plate (With gasket) Note) Mounting screws DXT5-4- A B NXT0- pc. pcs. Note) DXT060-5-B, DXT5-4-B are for the continuous duty type. Flow-rate Characteristics/Weight Flow-rate characteristics Valve model (P A) (A R) (R A) (A P) VO07 VO07V (Vacuum spec. type) VO07E (Continuous duty type) C[dm /(s bar)] 0.4 b 0.8 Cv C[dm /(s bar)] 0.4 b 0. Cv 0.08 C[dm /(s bar)] 0.6 b 0.8 Cv 0.09 C[dm /(s bar)] 0.4 b 0.8 Cv VO07Y (Energy-saving type) VO07W (Energy-saving, Vacuum spec. type) Weight Grommet 0.5 kg 5

8 R P Series VT07 Dimensions: Common Exhaust VV F G: 00 H: (Pitch) P = 6 8 L 9 0 L Max. 0 P R DIN terminal (D, DZ) Applicable cable O.D. ø6 to ø8 Pg9 Grommet (G, H) For 4 x M4 (For mounting) /8" [(P), (R) port] (Station n) (Station ) (5) A A 40 /8" [(A) port] (Pitch) P = 6 L Dimension L L L n n: Stations Formula L = 6 x n + 6 L = 6 x n + 0 6

9 Port Solenoid Valve Direct Operated Poppet Type Series VT07 Dimensions: Individual Exhaust VV F (Pitch) P = DIN terminal (D, DZ) 8 7 /8" [(R) port] L Applicable cable O.D. ø6 to ø8 Grommet (G, H) (Pitch) P = For 4 x M4 (For mounting) 4.6 R R P () Pg9 0 /4" [(P) port] 8.5 G: 00 H: L (Station n) (Station ) Max A A /4", /8" [(A) port] (Pitch) P = 6 L Dimension L L L n n: Stations Formula L = 6 x n + 4 L = 6 x n + 7

10 Series VT07 Specific Product Precautions Be sure to read before handling. Refer to back cover for Safety Instructions and Handling Precautions for SMC Products (M-E0-) for /4/5 Port Solenoid Valve Precautions. Warning Mounting When mounting a valve on the manifold base, N.C. and N.O. can be reversed by the function plate orientation. Also, since the cylinder operates in reverse, confirm if the function plate is correctly mounted or not. N.C. specification N.O. specification Changing from N.C. to N.O. This product is delivered as N.C. valve. If N.O. valve is required, remove mounting screws of the required valve and turn over the function plate. (Make sure that there are gaskets on both sides of the plate.) Then, tighten the mounting screws to fix the valve to the manifold base. Port z Port x Port c Port positions for manifold solenoid valve body Function plate Figure: For N.C. Function plate Specifications N.C. N.O. Function plate No mark NO. Each valve is fixed to the manifold base with two M4 mounting screws. Tighten the screws firmly when re-mounting.. For mounting, tighten M4 or equivalent screws evenly into the mounting holes of the manifold base. Tightening torque of the mounting screw (M4):.4 N m Piping. For the common exhaust type, pressurization or evacuation of the (R) port can cause a malfunction. 8

11 Safety Instructions : Warning: Danger : indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of, Warning or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) ), and other safety regulations. ) ISO 444: Pneumatic fluid power General rules relating to systems. ISO 44: Hydraulic fluid power General rules relating to systems. IEC 6004-: Safety of machinery Electrical equipment of machines. (Part : General requirements) ISO 08-: Manipulating industrial robots Safety. etc. Warning. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.. Do not service or attempt to remove product and machinery/ equipment until safety is confirmed.. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed.. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully.. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions.. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight.. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog.. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited warranty and Disclaimer/ Compliance Requirements The product used is subject to the following Limited warranty and Disclaimer and Compliance Requirements. Read and accept them before using the product. Limited warranty and Disclaimer. The warranty period of the product is year in service or.5 years after the product is delivered, whichever is first. ) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product.. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. ) Vacuum pads are excluded from this year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty. Compliance Requirements. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or any other weapon is strictly prohibited.. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed. Safety Instructions Be sure to read Handling Precautions for SMC Products (M-E0-) before using. Akihabara UDX 5F, 4-4-, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: Fax: SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. D-G st printing QW printing QW 850SZ Printed in Japan.

12 Port Solenoid Valve Direct Operated Poppet Type Series VT7 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable for use in vacuum applications 0. kpa (For vacuum specifications: VT/VO7V) A single valve with 6 valve functions (Universal porting type) Selective porting can provide 6 valve functions, such as N.C. valve, N.O. valve, Divider valve, Selector valve etc. V T T 0 7 G 0 Body type Body ported Manifold Valve option Nil Standard type E Continuous duty type V For vacuum Option Rated voltage 00 VAC, Hz 00 VAC, Hz 0 VAC, Hz 4 0 VAC, Hz 5 4 V 6 V 7 40 VAC, Hz 9 Other Option How to Order Thread type Nil F N T CE-compliant Rc G NPT NPTF Nil Q CE-compliant Electrical entry: D/DO only Port size Nil Without port (For manifold) 0 4 (8A) VV06 V00 S070 VQD VKF VK VT VS JIS Symbol G H C T D Electrical entry Grommet, 00 mm lead wire Grommet, 600 mm lead wire Conduit Conduit terminal DIN terminal Light/Surge voltage suppressor Electrical entry G H C T D Symbol Nil Note) S Note) Z Note) S: With surge voltage suppressor Note) Refer to the figure below. Z: With light/surge voltage suppressor As to the case of rated voltage [Others (9)], please contact SMC. Surge voltage suppressor mounting part (For G ) Surge voltage suppressor Manifold Model VO7(-Q) Applicable manifold type Common or individual exhaust Accessory O-ring (P0, 4 pcs.) Note) Bolts (M4 x 0.7 x 0, pcs.) Note) It is not applied to Continuous duty type. Refer to the accessories on page

13 Series VT7 Flow Characteristics/Mass Standard Specifications Type of actuation Fluid Operating pressure range Ambient and fluid temperature Response time () Max. operating frequency Lubrication Mounting orientation Shock/Vibration resistance () Enclosure Electrical entry rated voltage (V) Allowable voltage fluctuation Apparent power () Power consumption () Light/Surge voltage suppressor (Not applicable for grommet type) AC (50/60 Hz) Inrush AC Holding AC Direct operated type position single solenoid Air 0 to 0.9 MPa 0 to 50 C (No freezing. Refer to page 5.) 0 ms or less (at the pressure of 0.5 MPa) 0 Hz Not required (Use turbine oil Class ISO VG, if lubricated.) Non-locking push type Unrestricted 50/50 m/s Dustproof Grommet, Conduit, Conduit terminal, DIN terminal 00, 00, 0, 0, 40 4, 5 to +0% of rated voltage 9 VA (50 Hz), 6 VA (60 Hz) VA (50 Hz), 7 VA (60 Hz) Without indicator light: 6 W, With indicator light: 6. W Varistor, Neon bulb Varistor, LED (Neon bulb for 00 V or more) Option Note ) Based on dynamic performance test, JIS B ( temperature: 0 C, at rated voltage, without surge suppressor) Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) At rated voltage Flow characteristics Valve model (P A) (A R) (R A) (A P) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv VT7 VT7V (Vacuum spec. type) VT7E (Continuous duty type) Note) Values for a single valve unit. It differs in the manifold case. Refer to manifold specifications on page 6. Mass Grommet 0.9kg Option Continuous duty type: VT7E Exclusive use of VT7E is recommended for continuous duty with long time loading.. This model is for continuous duty, not for high cycle rates. But even in low cycle rates, if energizing the valve more than once a day, please consult with SMC.. Energizing solenoid should be done at least once in 0 days. Vacuum spec. type: VT7V This vacuum model has less air leakage than the standard model under low pressure. It is recommended for vacuum application.. Since this valve has slight air leakage, it can not be used for vacuum holding (including positive pressure holding) in the pressure container. Specifications different from standard are as follows. Operating pressure range 0. kpa to 0. MPa 60 Construction No. Description Body Spool valve De-energized Operation principles <De-energized> Spool valve w is pushed upward by the return spring e, port P is closed, and port A and port R are opened. Component Parts Material Note Aluminum die-casted Color: Platinum silver Aluminum, NBR Energized <Energized> When an electric current is applied to the molded coil r, the armature t is attracted to the core y, and through the push rod u, it pushes down the spool valve w. Then, port P and port A are connected. At this time, there will be gaps between the armature t and the core y, but the armature will be magnetically attracted to the core y.

14 Port Solenoid Valve Direct Operated Poppet Type Series VT7 Dimensions Grommet: VT7- G Conduit: VT7- C fitting position 4 positions per 90 ( 00 Note) (Lead wire length) fitting position 4 positions per 90 ( 80 (Lead wire length) x M6 mounting hole For top mounting (M4) x M6 mounting hole For top mounting (M4) ( positioning pin) ( positioning pin) x /4 x /4 x M6 x for bottom mounting Note) There is also ÒVT7- HÓ (Lead wire length: 600 mm). Conduit terminal: VT7- T DIN terminal: VT7- D x M6 x for bottom mounting VV06 V00 S070 VQD VKF VK VT VS fitting position 4 positions per 90 x M6 mounting hole For top mounting (M4) fitting position 4 positions per 90 x M6 mounting hole For top mounting (M4) x /4 ( positioning pin) x /4 x M6 x for bottom mounting ( positioning pin) Max.0 DIN terminal facing upward (0.6) x M6 x for bottom mounting Applicable cable O.D. 6 to 6

15 Series VT7 Manifold Specifications VT7 manifold is B mount style and available both as a common exhaust and individual exhaust model. VV A Common exhaust Individual exhaust VV VV VV7 Please indicate manifold base type, applicable manifold valve and blanking plate when ordering. Ordering example: VV A pc. (5-station manifold base) VO7-G 4 pcs. PVT7-5-A pc. (Blanking plate) Manifold Specifications How to Order Manifold A Manifold type Max. number of stations Applicable solenoid valve Exhaust port Symbol Type Common () Base type: /4 VT7 manifold Individual Valve stations 0 stations 0 0 stations Max. 0 P Base (Side) 4 ( 8 ) Base (Side) 4 Thread type Rc G NPT NPTF B mount 0 stations () VO7 - (-Q) () Port location (Direction)/Port size A Base (Side) 4 Base (Side) 4 Option A Mounting bracket R Base (Side) 4 ( 8 ) Base (Side) 4 Note ) For more than stations, supply air both sides of P port. The common exhaust type should exhaust from both of the R port. Note ) In the case of common exhaust type, R and P ports size can be Rc /8 by using a mounting adaptor. Note ) Can also be applied to Series VVT0 manifold. Nil F N T A port size (Base piping) /4 Symbol Symbol Passage P R Common Common Common exhaust type only Porting specifications A Side Common Individual Side Accessory for Applicable Solenoid Description O-ring Hexagon socket head screw Part no. P0 P0F Max. 0.7 x 0 Qty 4 Note Standard type vacuum specifications type Continuous duty type Option Description Blanking plate (With screw, O-ring) Mounting bracket (With screw) Part no. PVT7-5-A DXT (For common exhaust) Flow Characteristics/Mass Flow characteristics Valve model (P A) (A R) (R A) (A P) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv VO7 VO7V (Vacuum spec. type) VO7E (Continuous duty type) Mass Grommet 0.kg 6

16 Port Solenoid Valve Direct Operated Poppet Type Series VT7 Dimensions: Common Exhaust (Interchangeable with VVT0 for mounting) Without mountingbracket: VV A single valve unit port location x 7 mounting hole P port A port R port n x /4 DIN terminal facing upward 6.6 Applicable cable O.D. 6 to 4 x /4 VV06 V00 S070 VQD L Dimension n: Stations VKF Stations L L L Formula L =46xn+9 L =46xn+4 VK VT With mountingadaptor: VV A 4 x 7 mounting hole VS n x /4 DIN terminal facing upward x /8 Applicable cable O.D. 6 to L Dimension n: Stations Stations L L L Formula L =46xn+89 L =46xn+59 6

17 Series VT7 Dimensions: Individual Exhaust Without mounting bracket/vv x 7 mounting hole Manual override Conduit (C) Grommet (G) Conduit terminal (T) DIN terminal (D) DIN terminal facing upward (6.6) n x /4 Applicable cable O.D. 6 to L Dimension L Stations L L n:stations Formula L =46xn+9 L =46xn+4 Precautions Be sure to read before handling. Refer to front matters 58 and 59for Safety Instructions and pages to 7 for /4/5 Port Solenoid Valve Precautions. Mounting Warning. When mounting valves on the manifold base, the mounting orientation is decided. If it is mounted in the wrong direction, connected equipment may malfunction. Mount it by referring to how to switch over from N.C. to N.O. specifications.. Each valve is fixed to the manifold base with two M4 mounting screws. Tighten the screws evenly when re-mounting. Tightening torque of the mounting screw (M4):.4 Nám. For mounting, tighten M4 or equivalent screws evenly into the mounting holes of the manifold base. Changing from N.C. to N.O. Universal porting permits convertibility N.C./N.O. by a simple 80 degree rotation. Mounting conditions for N.C. and N.O. is indicated as below figure. Exhaust port type Common exhaust Individual exhaust Valve N.C. * Changing from N.C. to N.O. This product is delivered as N.C. valve. If N.O. valve is needed, remove mounting screws of the required valve and turn the valve at 80 degrees. (Make sure that there are O-rings fixed on 4 positions of the valve surface.) Then, tighten the mounting screws to fix the valve to the manifold base. N.O. 64

18 Series VT7 Specific Product Precautions Be sure to read before handling. Refer to Front matters 58 and 59 for Safety Instructions and pages to 7 for /4/5 Port Solenoid Valve Precautions.. A bleed port for the main valve is located at the bottom of the solenoid valve. Since blocking it causes malfunction, do not block it. Ordinarily, when the solenoid valve is mounted on a metal surface, it can breathe through the breather hole, via the breather groove. However, in particular, if the surface to be mounted is made of the rubber, the rubber could deform and block the hole.. Make sure that dust and/or other foreign materials should not enter the valve from the unused port (e.g. exhaust port). Also, since there is a bleed port for the armature in the manual override, do not allow accumulation of dust and/or other foreign materials to block bleed port. Bleed air passage Manual override Bleed port of main valve AC Change of Electrical Entry Angle. Series VT7 can change electrical entry angle. (4 positions). How to change: Loosen the nut (), remove the coil () from the body assembly (), place the positioning pin (4) at the required place, put back the coil () to its place, and tighten sufficiently with lock nut (). Surge voltage suppressor (S) Light/Surge Voltage Suppressor Varistor Diode Grommet (G) Conduit (C) () () (4) () Conduit terminal (T) DIN terminal (D) Varistor Neon bulb VV06 V00 S070 VQD VKF VK VT VS AC Varistor Bottom of the solenoid valve How to Calculate the Flow Rate For obtaining the flow rate, refer to front matters 44 to 47. Light/Surge voltage suppressor (Z) None Varistor 48 V or less Protection circuit for light/surge voltage suppressor is not the polarity type. Varistor 00 V Neon bulb Lead Wire Color (Grommet) Voltage 00 VAC 00 VAC Other Color Blue Red Red (+), Black ( ) Gray Electrical Connection DIN terminal is connected inside as in the figure below. Connect to the corresponding power supply. Ground 65

19 Series VT7. Disassembly ) After loosening the thread (), then if the cover (4) is pulled in the direction of the thread, the connector will be removed from the body of equipment (solenoid, etc.). ) Pull out the screw (), then remove the gasket (a) or (b). ) On the bottom part of the terminal block (), there s a cut-off part (indication of an arrow) (a). If a small flat head screwdriver is inserted between the opening in the bottom, terminal block () will be removed from the cover (4). (Refer to graph at right.) 4) Remove the cable gland (5) and plain washer (6) and rubber seal (7).. Wiring ) Pass them through the cable (8) in the order of cable ground (5), washer (6), rubber seal (7), and then insert into the housing (4). ) Dimensions of the cable (8) are as shown in the right figure. Skin the cable and crimp the crimped terminal (9) to the edges. ) Remove the screw with washer (e) from the bracket (e). (Loosen in the case of Y-shape type terminal.) As shown in the right figure, mount a crimped terminal (9), and then again tighten the screw (e). Note) Tighten within the tightening torque of 0.5 N m ±5%. Note: a It is possible to wire even in the state of bare wire. In that case, loosen the screw with washer (e) and place a lead wire into the bracket (d), and then tighten it once again. b The maximum size for the round terminal (9) is.5 mm.5 and for the Y terminal is.5 mm 4. c Cable (8) external: ø6 to ø Note) For the one with the external external dimension ranged between ø9 to ø remove the inside parts of the rubber seal (7) before using.. Assembly ) Terminal box () connected with housing (4) should be reinstated. (Push it down until you hear the click sound.) ) Putting rubber seal (7), plain washer (6), in this order into the cable introducing slit on the housing (4), then further tighten the cable gland (5) securely. ) By inserting gasket (a) or (b) between the bottom part of the terminal box () and a plug on an equipment, screw in () on top of the housing (4) and tighten it. Note) Tighten within the tightening torque of 0.5 N m ±0%. Note: The orientation of a connector can be changed arbitrarily, depending on the combination of a housing (4) and a terminal box (). Comparison between the Product Model No. and the Part No. Note ) mark in the product model numbers denotes the rated voltage. Note ) mark denotes the valve option. Note ) mark and mark are for coil part number and coil assembly with terminal the rated voltage. Example ) In the case of VT7-00GB-05 Example ) In the case of PVT7-5G Note 4) In the case of CE-compliant products (-Q), coils are not shipped together. Product model no. VT/O7 - G(-0) VT/O7 - GS(-0) VT/O7 - H(-0) VT/O7 - HS(-0) VT/O7 - C(-0) VT/O7 - CS(-0) VT/O7 - T(-0) VT/O7 - TS(-0) VT/O7 - TZ(-0) VT/O7 - D(-0) VT/O7 - DS(-0) VT/O7 - DZ(-0) How to Use DIN Terminal no. PVT7-00GB- PVT7- G PVT7-00GB- L06 PVT7- G-06 PVT7-00CB- PVT7- C PVT7-00DB- PVT7-00DB- PVT7-00DB- Exploded view () (a) (d) (b) (e) (b) () (c) (9) (4) (a) (6) (7) (e) (9) (e) Magnifying figure Self-up screw assembly with terminal part no. PVT7-00TBT- PVT7-00TBTS- PVT7-00TBTZ- PVT7-00DBT- PVT7-00DBTS- PVT7-00DBTZ- When the rated voltage is AC and if it is assembled with the coil for, response may be delayed and occur malfunction. Also, for valves, when the coil for AC is assembled, it occurs malfunction. For AC valves, assemble the coil for AC, and for valves, assemble the coil for. (5) (8) Connector for DIN Terminal Rated voltage 00 VAC 00 VAC 4 V For other rated voltages, please consult with SMC. Without light/surge voltage suppressor (D) GDMA With surge voltage suppressor (DS) GDMA-S GDMA-S GDMA-S5 Light/Surge voltage suppressor (DZ) GDMA-Z GDMA-Z GDMA-Z5 66

20 Port Solenoid Valve Direct Operated Poppet Type Series VT5 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 8 x 5 (Grommet) C: 0.6 dm /(s bar) {Rc /8 (Passage )} A single valve with 6 valve functions (Universal porting type) Six valve functions can be attained by selecting the piping ports. (Enabling the N.C. valve, N.O. valve, divider valve, selector valve, etc. to be used as desired.) Suitable for use in vacuum applications 0. kpa (For vacuum specifications type: VT/VO5V) VT5- T JIS Symbol VT5- C VT5- D VT5- G VT5 For manifold: Enter VO. Valve option Nil V Option Manifold Standard For vacuum Port size 4 8 Without connection port (For manifold) Model VO5-00 (-Q) Specifications Type of actuation Fluid Operating pressure range Ambient and fluid temperature Max. operating frequency Response time () Lubrication Shock/Vibration resistance () Enclosure 0 G Nil Q CE-compliant Electrical entry: D/DO/DL/DLO only Surge voltage suppressor Nil None With surge voltage suppressor AC: Can be attached to Grommet, Conduit, S Conduit terminal. : Can be attached to Grommet, Conduit, Conduit terminal. Direct operated type position single solenoid Air 0 to.0 MPa 5 to 50 C 5 Hz 0 ms or less (at the pressure of 0.5 MPa) Not required (Use turbine oil Class ISO VG, if lubricated.) Non-locking push type 50/50 m/s Dustproof Note ) Based on dynamic performance test, JIS B ( temperature: 0 C, at rated voltage, without surge suppressor) Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Solenoid Specifications Electrical entry rated voltage Allowable voltage fluctuation Apparent power () Power consumption () Note ) At rated voltage Rated voltage 00 VAC, 50/60 Hz 00 VAC, 50/60 Hz 0 VAC, 50/60 Hz 4 0 VAC, 50/60 Hz 5 4 V 6 V 7 40 VAC, 50/60 Hz 9 Other Option How to Order Applicable manifold B mount common exhaust type AC Inrush Holding 50 Hz 60 Hz 50 Hz 60 Hz Nil M Electrical entry G C D T TL DL Non-locking type Locking type (Tool required) Grommet, Lead wire length 00 mm Conduit DIN terminal Conduit terminal Terminal with indicator light DIN terminal with indicator light Thread type Nil F N T Accessory Gasket (DXT08--) Bolts (DXT08-9-, pcs.) Grommet, Conduit, DIN terminal, Conduit terminal 00, 00 VAC, 50/60 Hz, 4 V 5 to +0% of rated voltage 75 VA 60 VA 7 VA 7 VA W Rc G NPT NPTF CE-compliant For the coil rated voltage (option ), please contact SMC. VV06 V00 S070 VQD VKF VK VT VS 67

21 Series VT5 Flow Characteristics/Mass Valve model Flow characteristics Port size (P A) (A R) (R A) (A P) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv / VT5 VT5V (Vacuum spec. type) VT5 VT5V (Vacuum spec. type) / Note) Values for a single valve unit. It differs in the manifold case. Refer to manifold specifications on page 60. Mass Grommet 0.55 kg (For AC) 0.60 kg (For ) Option. For vacuum Pressure range 0. kpa to 0. MPa This vacuum model has less air leakage than the standard model under low pressure. It is recommended for vacuum application. ) Since this valve has slight air leakage, it can not be used for holding vacuum (including positive pressure holding) in the pressure container.. With surge voltage suppressor, with indicator light Surge Voltage Suppressor Grommet (GS) Conduit (CS) Conduit terminal (TS) Circuit for Indicator Light DIN terminal with indicator light (DL) Conduit terminal with indicator light (TL) Grommet type Varistor Neon bulb Surge voltage suppressor AC AC Varistor Neon bulb Red (+) ( ) Black Diode Varistor Construction No. De-energized o Retainer Operation principle <De-energized> The spool e is pushed upward by the force of the spring r and the air passage between port x and port c is opened and port z is blocked. Air flow direction: z Block, x c Component Parts Description Body Cover Spool valve Material Aluminum die-casted Aluminum die-casted Aluminum, NBR u Plunger w Cover y i Over travel assembly q Body e Spool valve t O-ring r Spool spring Note Platinum silver Platinum silver Energized <Energized> When the coil y is energized the plunger u is pulled down depressing the spool e via the overtravel assembly i and the air passage between port z and port x is opened and port c is blocked. Air flow direction: z x, c Block. with lock ) Using a screwdriver, push the manual override button that is located in the head portion of the solenoid valve in order to directly push the spool valve downward, thus causing the valve to switch. ) With the button remaining pushed down, turn it approximately 90 clockwise or counterclockwise to maintain the manual override locked state. ) To revert to the original state, keep the button pushed down and turn it approximately 90 clockwise. 68

22 Port Solenoid Valve Direct Operated Poppet Type Series VT5 Dimensions Grommet (G) Conduit (C) x mounting groove Lead wire length 80 x mounting groove 00 x Rc /4, /8 Width across flats x Rc /4, /8 Width across flats VV06 V00 S070 x ø4.5 mounting hole VQD VKF DIN terminal (D) Conduit terminal (T) VK Connector Applicable cable O.D. ø6 to ø VT VS x mounting groove x mounting groove x Rc /4, /8 Width across flats x Rc /4, /8 Width across flats With locking manual override Conduit terminal with indicator light (TL) Light 9. (With locking type manual override) x mounting groove x Rc /4, /8 Width across flats 69

23 Series VT5 Manifold Specifications Series VT5 Manifold Model has a B mount style with common exhaust. Common exhaust VVT Porting specifications Symbol P 0 Side Side How to Order Manifold Manifold Specifications Manifold type Max. number of stations Applicable solenoid valve Exhaust port type Common Option A Side Bottom 0 7 R Side Side Valve stations stations 7 stations Port size Symbol Port size Exhaust port type Common exhaust Port location/port size P A R Base Base Base 4, 8 4, 8 4, 8 Instruct by specifying the valves and blanking plate to be mounted on the manifold along with the manifold base model no. <Example> VVT40-05 pc. VO5-00G 4 pcs. DXT08-A pc. B mount 7 stations Note) VO5-00 (-Q) P Side Blanking plate (With gasket, screw) Thread type Port direction A Side/Bottom DXT08-A Note) If there are more than 4 stations, supply air from both P ports and exhaust from both R ports. Nil F N T Rc G NPT NPTF R Side Accessory for Applicable Description Part no. Qty. Manifold gasket DXT08-- pc. Hexagon socket head screw DXT08-9- pcs. Flow Characteristics/Mass VO5 Valve model VO5V (Vacuum spec. type) Flow characteristics (P A) (A R) (R A) (A P) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv Mass Grommet 0.58 kg (For AC) 0.6 kg (For ) Warning When mounting valves on the manifold base, the mounting orientation is decided. If it is mounted in the wrong direction, connected equipment may malfunction. Mount it by referring to external dimensions on page 6. Besides, the external dimensions are showing the case of N.C. specifications. Precautions Changing from N.C. to N.O. The valves are assembled as N.C. valves at the time of shipment. By removing the two retaining screws from the desired valves, and rotating each valve body 80 and reassembling it on the manifold base, it is possible to reassemble an N.C. valve as an N.O. valve. (When doing so, make sure that a gasket is attached to the mounting surface of the valve.) Properly tighten the screws. The tightening torque of the retaining screws is N m. 60

24 Port Solenoid Valve Direct Operated Poppet Type Series VT5 Dimensions Common exhaust Pitch x ø9 mounting hole Conduit DIN terminal (T) Grommet (G) terminal (D) Conduit (C) 4 x Rc /4, /8 Max. For bottom ported n x Rc /4, /8 Bottom ported Pitch A single valve unit port location VV06 V00 Blanking plate Port () A, Port () S070 VQD Pitch n x Rc /4, /8 Symbol L L n Formula: L = 46n + 9, L = 46n Port () n: Stations VKF VK VT VS 6

25 Series VT5 Specific Product Precautions Be sure to read before handling. Refer to front matters 58 and 59 for Safety Instructions and pages to 7 for /4/5 Port Solenoid Valve Precautions.. The bottom of the solenoid valve has a breather hole for the main valve. Take proper measures to prevent this hole from being blocked as this will lead to a malfunction. Ordinarily, when the solenoid valve is mounted on a metal surface, it can breathe through the breather hole, via the breather groove. However, in particular, if the surface to be mounted is made of the rubber, the rubber could deform and block the hole. Bleed groove Grommet Bleed port on main valve Bottom of the solenoid valve. Make sure that dust and/or other foreign materials do not enter the valve from the unused port (e.g. exhaust port). The grommet portion contains a breather hole for the core. Take proper measures to prevent dust or foreign matter from accumulating in this area. Electrical Connection For wiring to DIN terminal, connect the positive (+) polar side with connector terminal no. and the negative ( ) side with connector terminal no. when the rated voltage is type. How to Calculate the Flow Rate For obtaining the flow rate, refer to front matters 44 to 47.. Disassembly ) After loosening the thread (), then if the cover (4) is pulled in the direction of the thread, the connector will be removed from the body of equipment (solenoid, etc.). ) Pull the screw (), and then remove gasket (a) or (b). ) On the bottom part of the terminal block (), there s a cut-off part (indication of an arrow) (a). If a small flat head screwdriver is inserted between the opening in the bottom, terminal block () will be removed from the cover (4). (Refer to the figure below.) 4) Remove the cable gland (5) and plain washer (6) and rubber seal (7).. Wiring ) Pass them through the cable (8) in the order of cable ground (5), washer (6), rubber seal (7), and then insert into the housing (4). ) Dimensions of the cable (8) are the figure as below. Skin the cable and crimp the crimped terminal (9) to the edges. ) Remove the screw with washer (e) from the bracket (e). (Loosen in the case of Y shape type terminal.) As shown in the below figure, mount a crimped terminal (9), and then again tighten the screw (e). Note) Tighten within the tightening torque of 0.5 N m ±5%. Note: a It is possible to wire even in the state of bare wire. In that case, loosen the screw with washer (e) and place a lead wire into the bracket (d), and then tighten it once again. b The maximum size for the round terminal (9) is.5 mm.5 and for the Y terminal is.5 mm 4. c Cable (8) external: ø6 to ø Note) For the one with the external dimension ranged between ø9 to ø remove the inside parts of the rubber seal (7) before using. How to Wire DIN Terminal. Assembly ) Terminal box () connected with housing (4) should be reinstated. (Push it down until you hear the click sound.) ) Putting rubber seal (7), plain washer (6), in this order into the cable introducing slit on the housing (4), then further tighten the cable gland (5) securely. ) By inserting gasket (a) or (b) between the bottom part of the terminal box () and a plug on an equipment, screw in () on top of the housing (4) and tighten it. Note) Tighten within the tightening torque of 0.5 N m ±0%. Note: The orientation of a connector can be changed arbitrarily, depending on the combination of a housing (4) and a terminal box (). Exploded view (d) (d) () (a) (e) (b) () (c) (4) (9) (a) (6) (7) (e) (e) (9) Magnifying figure Self-up screw (5) (8) Connector for DIN Terminal Description DIN connector Part no. GDMC 6

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

E/P Regulator (DeviceNet TM type) ITV1000/2000/3000/2090-DE* Series

E/P Regulator (DeviceNet TM type) ITV1000/2000/3000/2090-DE* Series Doc. No. ITV2-OM00095-B P R O D U C T N A M E E/P Regulator (DeviceNet TM type) MODEL/ Series/ Product Number ITV1000/2000/3000/2090-DE* Series Install and operate the product only after reading the Operation

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00

More information

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double 4/ Port Solenoid Valve Rubber Seal VZ1000/000/000 Solenoid Valve Variations Port Size Effective area (mm 2 ) Position solenoid Voltage Electrical entry Option/ Indicator light and surge voltage suppressor

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Model position position Type of actuation

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

NAMUR Mount Hygienic Valve

NAMUR Mount Hygienic Valve NF097-D NMUR Mount Hygienic Valve For Wash Down pplications Series VFN Features Engineered Plastic PPS Body (Polyphenylene Sulfide) provides high temperature and chemical/corrosion resistance for use in

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve Series VN Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

STC 3S012-020-A Series Solenoid Valves

STC 3S012-020-A Series Solenoid Valves STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Series VM. Mechanical Valves VM200. VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25

Series VM. Mechanical Valves VM200. VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25 Mechanical Valves Series VM Model Dimensions (mm) VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25 VM100 Side ported 17 x 44 x 25 Bottom ported 17 x 44 x 30 VM200 25 x 40 x 52 One way roller

More information

240% 19% reduced. Compact Slide. New. New. Improved by up to. With new high rigidity linear guide. 369g. Series MXH CAT.ES20-218A.

240% 19% reduced. Compact Slide. New. New. Improved by up to. With new high rigidity linear guide. 369g. Series MXH CAT.ES20-218A. Compact Slide New ø, ø, ø, ø RoHS Allowable moment Improved by up to 2% With new high rigidity linear guide Allowable moment improvement illustrated below Allowable moment (N m). F Pitch moment Mp Yaw

More information

Line-Mounted Valves L Series

Line-Mounted Valves L Series Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

HL-5000. Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

HL-5000. Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure. General-purpose Limit Switch CSM DS_E_3_ Economical, Miniature Limit Switch Boasting Rigid Construction The Head, Box, and Cover mate with ridged surfaces to maintain strength. A unique Head structure

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

Valves. Sub-Base Mounted Valves to ISO 5599/2

Valves. Sub-Base Mounted Valves to ISO 5599/2 Valves Sub-Base Mounted Valves to ISO 5599/2 General Information ISO 1, ISO 2 and ISO 3 valve series incorporate the famous Numatics lapped spool and sleeve for ultimate service life. Due to the great

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the

More information

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information Safety Safety Is Your Responsibility DANGER To avoid personal injury or death, carefully read and understand all instructions pertaining to the Anthony Liftgates product. Do not attempt to install, operate,

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting Female NPT Thread 3/8 OD Tube 3/8 Push-In Fitting 2P050 Series Solenoid Valve Specifications Valve Model 2P050-1/4 2P050-3/8

More information

IMPORTANT DOCUMENTATION DO NOT DISCARD!

IMPORTANT DOCUMENTATION DO NOT DISCARD! PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance

More information

type V46, solenoid or pneumatic operated

type V46, solenoid or pneumatic operated SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot

More information

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation Air Catch Sensor Series For Workpiece Placement Confirmation No-contact sensor for confirming workpiece placement, with a configuration that is less affected by supply pressure change. Easy-to-set-up LED

More information

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

DeZURIK 3-20 BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT Instruction D10386 August 2013 Instructions These instructions provide installation, operation and maintenance information for BAW Butterfly Valves.

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry. y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock

More information

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

G1/4 Q8. Standard with biased position

G1/4 Q8. Standard with biased position Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

TS93 EMR T/PT/TDE. Surface applied door closer

TS93 EMR T/PT/TDE. Surface applied door closer TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Extra-long stroke even without levers. (:.7 mm) Clip contacts with highly reliable slide contact

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

3/2-way pneumatic cartridge solenoid valve

3/2-way pneumatic cartridge solenoid valve 3/2-way pneumatic cartridge solenoid valve Compact design with 11 mm width per station Orifices from 0.5 mm (9 bar) to 1.2 mm (1.5 bar) High durability and reliability Low power consumption, as well as

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R MAC120R MAC150R MAC 200R Serial # Fuji Clean USA 41-2 Greenwood Road Brunswick, Maine 04011 207-406-2729 www.macblowers.com MACBlowers The Intelligent

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,

More information

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007 Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid

More information

EX##-OMN0011-A. SI unit for EtherCAT PRODUCT NAME. EX260 Series MODEL/ Series

EX##-OMN0011-A. SI unit for EtherCAT PRODUCT NAME. EX260 Series MODEL/ Series SI unit for EtherCAT PRODUCT NAME EX260 Series MODEL/ Series Contents Safety Instructions 2 How to Order 7 Summary of Product elements 8 Installation and Cabling 9 General instructions on installation

More information

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47) 47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC 8mm Solenoid Valve Typical Applications Portable Equipment Blood Pressure Monitoring Wound Therapy Air and Oxygen Delivery Sensor Zeroing Product Specifications Mechanical Valve Type: 3-Way, Solenoid-actuated

More information

Socket case Socket. Easy insertion of tube by the floating mechanism to adjust to the case hole. Clamp bolt. Possible to clamp with one bolt at once.

Socket case Socket. Easy insertion of tube by the floating mechanism to adjust to the case hole. Clamp bolt. Possible to clamp with one bolt at once. Multi-connector Series DM RoHS The use of the multiconnector enables panel mount connections with other apparatus and can provide the reliability of one-touch installation and removal of multi-tubes (nylon,

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

3/2 Solenoid Cartridge Valve, Size 6

3/2 Solenoid Cartridge Valve, Size 6 / Solenoid Cartridge Valve, Size 6 Q max = l/min, p max = 5 bar Bidirectional seat-valve shut-off, direct acting Guided valve spool and poppet Two spool variants are available Available in two mounting

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils

More information

Electro-Pneumatic Bus Door Control Mechanism

Electro-Pneumatic Bus Door Control Mechanism Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with

More information

Valve systems Base plates, according to standard ISO 5599-1. Brochure

Valve systems Base plates, according to standard ISO 5599-1. Brochure ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure

More information

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual Dive Rite 200 & 300 Bar Isolator Manifold Service Manual Principal Photography and Text by Pete Nawrocky Copyright 2003 Lamartek Inc. D/B/A Dive Rite 0 Warning This manual is only to be used as a guide

More information

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions 4057250/8 IM-P405-16 AB Issue 8 ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Operation

More information

MODEL G300 BRAKE BLEEDER

MODEL G300 BRAKE BLEEDER MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY

More information

http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } 100 17.5 {175}

http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } 100 17.5 {175} Solenoid Valve Features 2 For DC power supply 3 For C power supply These models realize high-pressure large-flow-rate control at 35 MPa {35 kgf/cm 2 } and 1 L/min (2) or 16 L/min (3). They are best suited

More information

Control block VOFA with safety function

Control block VOFA with safety function Key features Innovative Versatile Reliable Easy to assemble Can be used for safe reversing of a hazardous movement (5/2-way solenoid valve) Can be used for safe venting (3/2-way solenoid valve function,

More information

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

DIAMOND Retractable Rodding Robot Model SPRAYROD-R 2004-12-21 2 1 (23) DIAMOND Retractable Rodding Robot Model SPRAYROD-R 2004-12-21 2 2 (23) Table of contents 1 TECHNICAL DESCRIPTION...4 1.1 MAIN DETAILS...5 1.2 COMPONENTS DESCRIPTION...5 1.2.1 Pneumatic

More information

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................

More information

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8 * U S 4 Specifications escriptions Bore size mm Actuation Working fluid ax. working pressure Pa in. working pressure Pa Withstanding pressure Pa Ambient temperature Port size Stroke length Rubber cushioned

More information

Denotes New Winner s Circle Product Line. Catalog HY15-3502/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY

Denotes New Winner s Circle Product Line. Catalog HY15-3502/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY Catalog HY-5/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI HIGH FLOW VALVE FAMILY See individual catalog pages for exact specifications. WAY SPOOL TYPE GS *... X / C9-.. Position,

More information

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP Feb 5, 2003 1 CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING COMPLETE SYSTEM CHECK - PNEUMATIC PUMP THE SYSTEM DOES

More information

MODEL T200-F18 MODEL T125-F18 Finish Nailers

MODEL T200-F18 MODEL T125-F18 Finish Nailers P MODEL T200-F18 MODEL T125-F18 Finish Nailers IMPORTANT! DO NOT DESTROY It is the customer s responsibility to have all operators and service personnel read and understand this manual. OPERATING MANUAL

More information

Round Housing with Side Ports

Round Housing with Side Ports Power Steering Steering Control Unit (SCU) Parts and Repair Information 5 Series Steering Control Units 001 Square Housing with Side Ports Round Housing with Side Ports T E L RP Round Housing with End

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

Electro-hydraulic pressure switches type DG

Electro-hydraulic pressure switches type DG Electro-hydraulic pressure switches type DG Pressure p max = 700 bar See also: For electronic pressure switches type DG 5 E see D 5440 E Analogous pressure transducer type DT 1 see D 5440 T Analogous pressure

More information

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information Sealed Subminiature Basic Switch Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series. Sealing by using rubber packing means the switch can be used in dust-proof

More information

Directional seated valves type VP 1

Directional seated valves type VP 1 Directional seated valves type VP 1 zero leakage, intended for general hydraulic applications and grease lubing systems Flow Q max Operation pressure p max = 15 lpm = 400 bar Individual valve Individual

More information

CHROME FRONT BRAKE MASTER CYLINDER KIT

CHROME FRONT BRAKE MASTER CYLINDER KIT -J075 REV. 009-0-0 CHROME FRONT BRAKE MASTER CYLINDER KIT GENERAL Kit Number 5-99D, 5-99D Models These Chrome Master Cylinder Kits are designed to replace the original equipment front brake master cylinder

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

CAT.ES120-4 A. Precision Clean Regulator. Series SRP. High precision, low flow consumption stainless steel regulator

CAT.ES120-4 A. Precision Clean Regulator. Series SRP. High precision, low flow consumption stainless steel regulator CAT.ES120-4 A Precision Clean Regulator Series SRP High precision, low flow consumption stainless steel regulator Precision Clean Regulator Series SRP High precision, low flow consumption stainless steel

More information

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

IOM SERIES 820-E/P Electro-Pneumatic Positioner

IOM SERIES 820-E/P Electro-Pneumatic Positioner FLUID CONTROL DIVISION Parker Hannifin Corporation 95 Edgewood Avenue New Britain, CT 06051 Telephone (860) 827-2300 IOM SERIES 820-E/P Electro-Pneumatic Positioner INSTALLATION, OPERATING & MAINTENANCE

More information

SQUARE D INDUSTRIAL CONTROL PRODUCTS

SQUARE D INDUSTRIAL CONTROL PRODUCTS SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and

More information