Single Core Conductor BETAtherm 155

Similar documents
Chemical resistance Accidental

The Quality Connection. BETAflam Fire Resistant Safety Cables

Tri-Rated Flexible PVC Equipment Wire

VIPERFLEX ELECTRIC CABLE

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

Cable flexibility Flexible. Chemical resistance Accidental

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

Fire retardant IEC

CONFLEX ELECTRIC CABLE

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

VDE-approved PVC-Control Cables

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

Flexible Control Cables

Power and Wiring Cables

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr /2009

Flexible cables for submersible products

MICROCABLES. A complete vision of your connectivity needs. Catalogue

APR 2016 Rev M

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

KNOW YOUR OPTIONS: 230 KV POWER CABLES

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

MV CABLE TYPE C

with coloured cores and overall copper screen UL/CSA... 17

COAX Cables Radio Frequency Cables

Section kv Power Cables

5.2. Overview. The better method to install solderless compression connectors on power cable

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

ISO VIEW OF AX SERIES XLR CABLE CONNECTOR

Outside Telephone Cable

Building Cables and Wires

ISO 9001 ISO CABLES AND WIRES CATALOGUE 2008

SPEC 55. Wire and cable. Applications. SPEC 55PC wire and cable insulation system. Features and benefits. Physical characteristics

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

Festoon 715 P PUR cable for flexible application in festoon systems

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

C A B L E P R O T E C T I O N

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

FIBER-OPTIC CABLES LWL-KABEL

Global cable expertise for rolling stock

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

Panduit 28 AWG Patch Cords Installation Guideline

Flygt flexible cables

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

Gulf Cable & Electrical Ind. Co.

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

TECHNICAL SPECIFICATION

PTC-Resistor Temperature-Sensors MINIKA to DIN and DIN

ETHERLINE Ethernet Cable, Connectors & Tools

Fibre optic cables MDIC LSZH

Standard Buccaneer - Ethernet

ODU MEDI-SNAP. Miniature Circular Connectors with Push-Pull Locking Made of Plastic or Metal.

Instrumentation Cable Power Cable Assembly Solutions...32

Communication, Signal & Data Cables

ZS10 Screw Clamp Terminal Block

3M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series

Series 8146/5-V37 and Series 8150/5-V37

Electronics and Soldering Notes

400 Series Buccaneer BUCCANEER POWER. bulgin

The range of rail-mounted terminal blocks. for a perfect electrical installation.

Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts

Automotive Wire and Cable Products

PVC YALITIMLI SÝNYAL VE KONTROL KABLOLARI PVC INSULATED SIGNAL AND CONTROL CABLES (VDE 0812-VDE 0814-VDE 0245)

How To Read A Pipe From A Sensor

E Series. E Series. Category 6 and 5e. Features

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

Cables and Accessories Selection Guide

< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10

Directory chapter 04

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

Allweather and Rubber Cables

Tubing and Accessories

GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.

VOLTS - Copper conductor PVC insulated SSA 1320, IEC & BS 6004 HO 7V - U With Solid Conductor - TYPE IEC 01. Insulation Thickness

Control cables CF880 PVC 12,5-5/ CF881 PVC 12,5-5/ CF890 igupur 12,5-20/ CF891 igupur 12,5-20/

HARTING Ethernet Cabling 8-poles Overview

Fire Resistant Cables

Servo Motor & Drive Cables

RADOX railway cables acc. to EN and EN Edition 2009

AMP Standard Terminals and Splices. RoHS. Ready

the quality par excellence Meghna Industries Manufacturer of : All types of fiberglass Cables

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

600V Power Cable 600V SOOW SOW

ACS-30-EU-EMDR-10-MOD

2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

HARTING Ethernet Cabling 4-poles Overview

100% EMI Emission Containment

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Cable Plug acc. to DIN EN , Form A

6 ELECTRICAL PARAMETERS

KSC Series Sealed Tact Switch for SMT

ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics

I-PEX MHF4 Micro Coaxial Connector

CLI CableLine Laser-printed Identification Cable markers and wire markers. Product information

Transcription:

Internet: www.synflex.de Single Core Conductor BETAtherm 155 Description BETAtherm 155 is a flexible low-voltage conductor consisting of a tinned copper stranded wire insulated with coloured electron-beam cross-linked polyolefine copolymer. Properties Due to its electron-beam cross-linked insulation, BETAtherm 155 achieves a special thermal resistance required for Class F. This results in excellent thermal resistance. However, it cannot even be melted at elevated temperatures. Skinning is simple and also possible at machines. BETAtherm cables are resistant to all common insulating varnishes. They are flame retardant. Application BETAtherm 155 can be used for the internal wiring of all electric machines and dry transformers, as well as in apparatus, machine and plant engineering and lighting applications. Due to the high thermal load capacity, it might be possible to reduce the conductor cross section and, therefore, save space and reduce the weight. Standards Thermal class F (155 C) according to IEC VDE 0295 / IEC 60228, class 5 RoHS compliant according to 2011/65 EC Conductor Tinned copper wire VDE 0295/ IEC 60228 class 5. The dimensions specified in the technical datasheet are regarded as standard values. The actual cross sections may vary. The cables are manufactured according to European standards with a metric conductor cross section, AWG sizes are approximate values and viceversa. Always observe relevant standards valid for divergent operating conditions when laying for greater Updated 10/16-1 -

Internet: www.synflex.de limit current loads. Delivery format Conductor cross section: Format mm² Length in m on a ring 0.25-0.75 200 1.0-10.0 100 16.0-25.0 50 35.0-95.0 25 Other cross sections available on request Color Green/yellow, black, light blue, dark blue, brown, red, white, grey, violet, orange, yellow, green. Other colours, also two colours, available on request. Updated 10/16-2 -

Single Core Conductor BETAtherm 155 Technical data Mechanical Bend radius Soldering resistance 4 x Außendurchmesser sehr gut Chemical Insulation Resistance Polyolefin-Copolymer elektronenstrahlvernetzt unempfindlich gegen gebräuchliche Imprägniermittel Thermal Thermal class Temperature range fixed application F -55 bis +155 C (nach IEC) Temperature range Short circuit +280 C Thermal resistance IEC 60216-2 / VDE 304 T 21(155 C/5000h) Burning behaviour flammwidrig EN/IEC 60332-1-2 Nominal cross section mm² 0,25 0,5 0,75 1 Strands x diameter mm 14 x 0,15 16 x 0,20 24 x 0,20 32 x 0,20 Cu-Litze Nenn-Durchmesser mm 0,65 0,90 1,15 1,25 Wall thickness Desired mm 0,45 0,48 0,53 0,58 Wall thickness min. mm 0,35 0,35 0,35 0,40 Outer diameter mm 1,55 ± 0,10 1,85 ± 0,20 2,20 ± 0,20 2,40 ± 0,20 Updated 10/16-3 -

Nominal cross section mm² 1,5 2,5 4 6 Strands x diameter mm 27 x 0,25 45 x 0,25 52 x 0,30 78 x 0,30 Cu-Litze Nenn-Durchmesser mm 1,55 2,05 2,55 3,10 Wall thickness Desired mm 0,70 0,80 0,80 0,80 Wall thickness min. mm 0,53 0,62 0,62 0,62 Outer diameter mm 2,95 ± 0,20 3,65 ± 0,20 4,15 ± 0,20 4,70 ± 0,20 Nominal cross section mm² 10 16 25 35 Strands x diameter mm 74 x 0,40 119 x 0,40 181 x 0,40 257 x 0,40 Cu-Litze Nenn-Durchmesser mm 4,10 5,0 6,20 7,70 Wall thickness Desired mm 1,00 1,00 1,20 1,20 Wall thickness min. mm 0,80 0,80 0,98 0,98 Outer diameter mm 6,10 ± 0,20 7,0 ± 0,40 8,60 ± 0,40 10,10 ± 0,40 Nominal cross section mm² 50 70 95 Strands x diameter mm 371 x 0,40 336 x 0,50 444 x 0,50 Cu-Litze Nenn-Durchmesser mm 9,70 11,20 12,8 Wall thickness Desired mm 1,40 1,40 1,60 Wall thickness min. mm 1,16 1,16 1,34 Outer diameter mm 12,50 ± 0,40 14,0 ± 0,40 16,0 ± 0,60 Electrical Rated voltage V U 0/U 300/500 V 1 mm 2 Rated voltage V U 0/U 450/750 V 1,5 mm 2 Nominal voltage with fixed and protected application U 0/U 600/1000 V 1,5 mm 2 Updated 10/16-4 -

Electrical Testing voltage V 5000 V/ 50 Hz/ 2 min Updated 10/16-5 -