2 - TeSys motor starters: enclosed version

Similar documents
Motor circuit-breakers

Pendant control stations 6

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Safety detection solutions

Manual Motor Starter MS 116 up to 16 A Technical Data

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Catalog January. Heavy industrial power applications Motor contactors and starters

Series 8146/5-V37 and Series 8150/5-V37

D-Line Contactors, Overload Relays and Accessories

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Tmax MCCBs. Molded case circuit breakers. Tmax

Circuit Breakers. Next Generation of Protection Capabilities

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

Safety automation solutions

R.C.C.B. s two-pole LEXIC

Manual motor starter MS116

Safety dialogue solutions

Electronic overload relay EF19 and EF45

Products and solutions for lifting systems

Plug and Socket Devices CES 63 A Series 8579

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

PSR The compact range Description

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Plug and Socket Devices SolConeX 16 A Series 8570

Electronic overload relay EF65, EF96 and EF146

RM4TG20 three-phase network control relay RM4-T - range V

Thermal-Magnetic Circuit Breaker M1-..

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Technicaldata General

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

E-STOP relays, safety gate monitors

HERZ-Thermal Actuators

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

Circuit Breakers. NRC Series. NRC Series

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Bulletin 150 SMC Flex Smart Motor Controller Specifications

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

Technical catalogue. Modular DIN rail components Installation contactors

Products and solutions for pumping, irrigation and piping

Control Panel Technical Guide

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

9 Control Equipment. Control Button Series 8082

Cable Plug acc. to DIN EN , Form A

Power Generation. Power Control PCL System Generator Set Control

Mureva Assembly surface mounted wiring devices

THERMAL RELAYS, MOTORSTARTERS

Type: DILM50(230V50HZ,240V60HZ) Article No.:

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

SMS 4 / SMS 5 safety mat Product information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

A good connection. International approvals.

Wiring diagrams. Compact NSX. Contents

Type: DILM9 10(24VDC) Article No.:

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

THE ADVANTAGES ARE YOURS

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Catalog. Modular DIN rail components Installation contactors

Type: DILM32 10(24V50HZ) Article No.:

Unified requirements for systems with voltages above 1 kv up to 15 kv

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

more than a breaker it s a breakthrough Compact NSX

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

ACS-30-EU-EMDR-10-MOD

General Informations 2 Technical data 3 Basic designs 4-8

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Data Sheet. Electro-mechanical counters Hengstler 800 series

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

SKR - industry relay

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Preventa Machine Safety Products

Bimetallic Overload Relay Specifications

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

HARTING Ethernet Cabling 8-poles Overview

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

8146/5 Series Breaker Panelboards

Sentron Series Circuit Breakers

PNOZsigma - Base units

3K Load-Break Switches The Program for Safety and Performance. sentric

Comparison of NEMA and IEC schematic diagrams

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A

Transcription:

Contents - TeSys motor starters: enclosed version Selection guide.... page / VARIO enclosed switch disconnectors b Pre-assembled.... page / b Assembled by the user... page / b Add-on modules... page / b VARIO enclosed switch disconnectors for the North American market, conforming to UL and CSA standards.... page /0 Enclosed thermal-magnetic motor circuit-breakers b TeSys GV ME v Standard.... page / v Assembly of a safety enclosure.... page / b TeSys GV PC...page / D.O.L. starters for motor control b 0. to 0 kw v With manual control and with magnetic circuit-breaker.... page / b. to kw v Without isolating device... page /0 v With isolating device.... page / b 0. to. kw v With -phase thermal overload relay.... page / b 0. to. kw v With thermal magnetic circuit-breaker and contactor... page /0 Star-delta starters for motor control b. to kw v Without isolating device... page / b. to kw v With isolating device.... page / b 0 to kw v Without isolating device... page / D.O.L. starters for control in category AC- b Without isolating device... page / b With isolating device.... page / 0 /0

integral contactor breaker and reversing contactor breaker b Enclosures and door interlock mechanisms for customer assembly... page / b For control and protection of motors... page / b For control and protection of resistive circuits in category AC-... page / b Auxiliary contact blocks and accessories... page / Enclosed D.O.L. starters for motor control for use in a machine subject to the application of Machinery Directive //CE b Non-reversing starters... page / b Reversing starters.... page / Enclosed D.O.L. starters for AS-Interface cabling system Selection guide.... page / b TeSys LF P and LF P.... page / b TeSys LF M and LF M.... page / 0 /

General selection guide Applications Type D.O.L. starters Standard starters Standard power ratings of -phase motors in AC- 00/ V kw 0.0 kw 0. 0 kw 0.. kw 0. kw Starters Isolation Manual p p p Auto p p Switch p Circuit-breaker p p p Fuse carrier Protection Short-circuit p p p Overload p p p p Communication References Non-reversing VpF VCFN VpFX GV ME GV PC GV LC GV NGC LE GVME LE M LE D Reversing LE K LE D Pages / and / /and / / /0 /0, / and / 0 /

Soft starters Starters for safety applications Starters for use on AS-Interface line Standard star-delta starters. kw 0.0 kw 0.0 kw 0.0 kw 0.0. kw. kw. kw p p p p p p p p p p p p p p p p p p p p p p p p p p p p LE K LE D GV ME LG K LG D LG K LG D LJ K LF P LF M LE K LE D LE F LE D LE D LE K LE D LE D LG K LJ K LF P LF M / and / / and / / /, /, / and / / and / /, / and / / and / 0 /

References VARIO enclosed switch disconnectors, pre-assembled 0 0 0 VCF 0GE VCF GE Enclosed switch disconnectors for high performance applications b -pole rotary switch disconnectors, 0 to 0 A, conforming to IEC 0-- and IEC 00. b Marking on operator O b Padlockable operating handle (padlocks not included). b IP degree of protection enclosures, sealable and lockable. b Cover lockable in position I (ON) up to A rating. -pole main and Emergency Stop switch disconnectors () Operator lthe Power Incorporated Handle Front plate AC- Dimensions at 00 V switch body Red, standard, padlockable with up to padlocks (Ø to Ø shank) Red, long, padlockable with up to padlocks (Ø to Ø shanks) Possible attachments () Reference Weight mm A kw kg Yellow 0 x 0 Yellow 0 x 0 -pole main switch disconnectors () Black, standard, padlockable with up to padlocks (Ø to Ø shank) Black, long, padlockable with up to padlocks (Ø to Ø shank) Black 0 x 0 Black 0 x 0 0 V0 VCF 0GE 0.00. V0 VCF 0GE 0.00 0. V0 VCF 0GE 0.00 V VCF GE 0.00 V VCF GE 0.00 0 V VCF GE 0.0 0 V VCF GE 0.0 00 V VCF GEN.0 0 V VCF GEN.0 0 V0 VBF 0GE 0.00. V0 VBF 0GE 0.00 0. V0 VBF 0GE 0.00 V VBF GE 0.00 V VBF GE 0.00 0 V VBF GE 0.0 0 V VBF GE 0.0 00 V VBF GEN.0 0 V VBF GEN.0 Enclosed switch disconnectors for standard applications b -pole rotary switch disconnectors, 0 to A, conforming to IEC 0--. b Degree of protection IP. -pole main and Emergency Stop switch disconnectors () Operator lthe Power Incorporated Handle Front plate AC- Dimensions at 00 V switch body Red padlockable, either by (Ø shank) or by padlocks (Ø shank) Possible attachments () Reference Weight mm A kw kg Yellow 0 x 0 0 VN VCFN GE () 0.. VN 0 VCFN 0GE () 0. 0. V0 0 VCFN GE 0. V 0 VCFN GE 0. V 0 VCFN 0GE 0. () For VCF and VBF enclosures, see page / / 0 Dimensions: page / / Schemes: page /

References VARIO enclosed switch disconnectors, assembled by the user 0 Empty enclosures IP enclosure with red padlockable handle operator and yellow front plate (for mounting a main or Emergency Stop switch disconnector) For switch body lthe Possible attachments () Reference Weight VBFX GE VN, VN 0 V0 V A kg 0 VCFX GE 0.0 V0 V 0 VCFX GE 0.0 V 0 VCFX GE 0.0 IP enclosure with black padlockable handle and black front plate (for mounting a main switch disconnector) VN, VN 0 V0 V 0 VBFX GE 0.0 V0 V 0 VBFX GE 0.0 V 0 VBFX GE 0.0 Switch bodies for standard applications () Description Rating Reference Weight A kg -pole switch disconnectors 0 VN 0.0 VN 0 0.0 00 Switch bodies for high performance applications () Description Rating Reference Weight A kg -pole switch disconnectors 0 V0 0.00 V0 0.00 0 V0 0.00 V 0.00 V 0.00 V0 0 V 0.00 V 0.00 () See pages / and / 0 Dimensions: page / Schemes: page / /

References VARIO enclosed switch disconnectors Add-on modules 0 VZ 0 VZ 0 Add-on modules for enclosures VCF and VBF Description Rating Reference Weight A kg Main pole module (mounted in enclosure) 0 VZ 0 0.00 VZ 0 0.00 0 VZ 0 0.00 VZ 0.00 VZ 0.00 0 VZ 0.00 VZ 0.00 0 0 Neutral pole modules with early make and late break contacts 0 to VZ 0.00 0 and VZ 0.00 00 and 0 VZ 0.0 Earthing modules 0 to VZ 0.00 0 and VZ 0.00 00 and 0 VZ 0.0 VZ VZ 0 Description Type of contacts Reference Weight kg Auxiliary contact block modules with auxiliary contacts N/O + N/C () VZ 0.00 N/O + N/O VZ 0 0.00 switch body add-on module on each side of the switch body VZ or VZ 0 + V0p or + VZ or VZ 0 or VZ or VZ + V0 + VZ or VZ or or VZ or VZ + to + VZ or VZ or or VZ 0p/VZ 0 to VZ + V + VZ 0p/VZ 0 to VZ add-on modules on each side of the switch body VZ 0p + VZ 0p + V0p + VZ 0p + VZ or VZ 0 or VZ or VZ VZ 0 + VZ 0 + V0 + VZ 0 + VZ or VZ 0 or VZ or VZ VZ + VZ + V + VZ + VZ or VZ 0 or VZ or VZ VZ + VZ + V + VZ + VZ or VZ 0 or VZ or VZ VZ + VZ + V + VZ + VZ or VZ 0 or VZ or VZ VZ + VZ + V + VZ + VZ or VZ 0 or VZ or VZ Note: 0 Schemes : page / /

References (continued) VARIO enclosed switch disconnectors Add-on modules 0 0 Add-on modules for enclosures VCFN GE and 0GE Description Rating Reference Weight A kg Main pole modules 0 VZN 0.00 VZN 0 0.00 Neutral pole module 0 and VZN 0.00 with early make and late break contacts Earthing module 0 and VZN 0.0 Description Type of contacts Reference Weight kg Auxiliary contact block modules N/O late make contact VZN 0 0.00 N/C early break contact VZN 0 0.00 switch body 0 VZN or VZN 0 + + VZN or VZN 0 or VN VZN or or VN 0 or VZN 0 or VZN 0 or VZN 0 or VZN 0 VZN 0 Schemes : page / /

Dimensions VARIO enclosed switch disconnectors Dimensions VCFN GE to VCFN 0GE 0 0, VCF or VBF 0GE to GE VCFX or VBFX GE to GE H b c c a a b c c H VpF 0GE to VpF GE, VpFX GE () 0 0 VpF GE and VpF GE () 0 0 0 VpFX GE and VpFX GE () 0 0 0 VCF or VBF GEN and GEN xø,, 0,, 0 References: pages / and / Schemes: page / /

Schemes VARIO enclosed switch disconnectors Schemes Switch disconnectors Enclosed or switch bodies Main pole module Neutral pole module /T /L /T /L /T /L Auxiliary contact blocks VZ VZ 0 VZN 0 VZN 0 0 References: pages / and / /

References VARIO enclosed switch disconnectors for the North American market, conforming to UL and CSA standards Enclosed switch disconnectors for high performance applications b -pole rotary switch disconnectors, to 0 A, conforming to IEC 0--, IEC 00, UL 0 and CSA. n. b Marking on operator O b Padlockable operating handle (padlocks not included). b NEMA type and type enclosures, IP degree of protection, sealable and lockable. -pole main and Emergency stop switch disconnectors () Operator Rating Standard Handle Front plate IEC UL power Dimensions (Ith) ratings of UL motors Red, standard, padlockable with up to padlocks (ØtoØ) Red, long, padlockable with up to padlocks (ØtoØ) Incorporated switch body Possible attachments Reference Weight 00 V 0 V 0 V 00 V mm A A HP HP HP kg Yellow 0 x 0 Yellow 0 x 0 0 0 0 V VC GUN 0.00 0 0 V VC GUN 0.00 0 0 0 V VC GUN 0.0 0 0 0 V VC GUN 0.0 00 0 0 V VC GUN.0 0 0 0 V VC GUN.0 Add-on modules for VC enclosure Description Rating Reference Weight Main pole module (mounted in enclosure) A VZ 0.00 VZ 0.00 0 VZ 0.00 VZ 0.00 kg Neutral pole module with early make and late break contacts 0 to VZ 0.00 0 and VZ 0.00 00 and 0 VZ 0.0 00 0 Earthing modules 0 to VZ 0.00 0 and VZ 0.00 00 and 0 VZ 0.0 VZ VZ Description Type of contacts Reference Weight kg Auxiliary contact block N/O + N/C () VZ 0.00 modules with auxiliary contacts N/O + N/O VZ 0 0.00 add-on module on each side of the switch body 0 VZ or VZ 0 + + VZ or VZ 0 or V or VZ or VZ + + VZ or VZ VZ 0 or to or VZ or VZ + + VZ or VZ or V or 0 VZ to VZ + + VZ to VZ /0

Dimensions, schemes VARIO enclosed switch disconnectors for the North American market, conforming to UL and CSA standards Dimensions VC GUN and VC GUN Fixing (rear view) xø,, VC GUN and VC GUN Fixing (rear view) 0, xø, VC GUN and VC GUN Fixing (rear view), 0, Schemes Switch disconnectors, xø, Enclosed switch disconnectors or switch bodies Main pole module Neutral pole module /L /L /T /T /L /T Auxiliary contact block modules VZ VZ 0 0 /

References Enclosed thermal-magnetic motor circuit-breakers GV ME and accessories, for customer assembly References Thermal-magnetic motor circuit-breakers GV ME For motor circuit-breakers and accessories: see pages /, / and /. Starters consisting of a GV ME motor circuit-breaker in an enclosure conform to standard IEC 0--. 00_ 000_ GV MC GV MP GV Ithe in enclosure (A) ME 0 ME 0 ME 0 ME 0 ME 0 ME 0 ME 0 ME 0 ME 0 ME ME ME 0 ME 0. 0. 0. 0.... Enclosures for thermal-magnetic circuit-breakers GV ME Type Degree of protection Possible no. of side mounting auxiliary contact blocks on GV ME Reference Weight LH side RH side kg Surface mounting, double insulated with protective conductor. Sealable cover Flush mounting, with protective conductor ME IP GV MC0 0.0 IP GV MC0 0.00 or GV MCK0 () 0.0 IP for GV MC0 0.00 temperature < + C IP (front face) GV MP0 0. IP (reduced GV MP0 0. IP (front face) GV MP0 0.0 IP (reduced GV MP0 0.0 00_ Front plate Description Reference Weight kg For direct control, through a panel, of a chassis mounted GV ME IP GV CP 0.00 0 00_ GV CP GV K0 Accessories common to all enclosures (to be ordered separately) Description Sold in lots of Unit reference Padlocking device () for GV ME operator (padlocking is only possible in the O position) Mushroom head Emergency stop pushbutton Ø 0 mm, red Sealing kit Neutral terminal to padlocks Ø to mm Weight kg GV V0 0.0 Spring return () GV K0 0.0 Latching () IP For enclosures and front plate Key release, key n GV K0 0.0 Turn to release GV K0 0. IP for temperature between + Cand+0 C + GV K0 () 0.0 0 GV E0 0.0 IP for temperature between - 0 C and + 0 C 0 GV E0 0.0 00 AB VVUBL 0.0 Partition 0 AB ACBL 0.00 () Enclosure GV MCK0 GV K0 mushroom head Emergency stop pushbutton GV Mp0 /

References dimensions Enclosed thermal-magnetic motor circuit-breakers GV P (for customer assembly) References (continued) Thermal-magnetic motor circuit-breakers GV P For motor circuit-breakers and accessories: see pages / and /. GV P0: operational current in enclosure limited to 0 A. Starters consisting of a GV P motor circuit-breaker in an enclosure conform to standards IEC/EN 0-- and IEC/EN 0-. (), for thermal-magnetic circuit-breakers GV P, up to 0 A Composition () Type Degree of Reference Weight protection of enclosure kg b Metal enclosure, b Black handle LU AP Padlocking in ON/OFF position b Circuit-breaker/handle adapter Surface mounting IP IK 0 GV PC0.000 b Metal enclosure, b Red handle LU AP Padlocking in OFF position b Circuit-breaker/handle adapter Surface mounting IP IK 0 GV PC0.000 () For special applications a GV L Dimensions Ø,,, 0 0,,, 0 /

References Enclosed thermal-magnetic motor circuit-breakers GV ME and accessories Assembly of a safety enclosure Thermal-magnetic motor circuit-breakers GV ME For motor circuit-breakers and accessories: see pages /, / and /. Starters consisting of a GV ME motor circuit-breaker in an enclosure conform to standard IEC 0--. 00_ GV MC GV ME 0 Ithe in enclosure (A) ME 0 ME 0 ME 0 ME 0 ME 0 ME 0 ME 0 ME 0 ME ME ME 0 ME 0. 0. 0. 0.... Enclosures for thermal-magnetic circuit-breakers GV ME Type Surface mounting, double insulated with protective conductor. Sealable cover Degree of protection Possible number of Reference side-mounting auxiliary contact blocks on GV ME ME Weight LH side RH side kg IP GV MC0 0.0 IP GV MC0 0.00 IP for temperature < + C or GV MCK0 () 0.0 GV MC0 0.00 Accessories common to all enclosures (to be ordered separately) Description Padlocking devices () for GV ME operator (padlocking is only possible in the O position) to padlocks Ø to mm Sold in lots of Unit reference Weight kg GV V0 0.0 00_ Mushroom head Emergency stop pushbutton Ø 0 mm, red Spring return () GV K0 0.0 Latching () IP Key release, key n Turn to release GV K0 0.0 GV K0 0. GV K0 () 0.0 GV K0 Sealing kit Neutral terminal For enclosures and front plate IP for temperature between + C and + 0 C 0 GV E0 0.0 IP for temperature between - 0 C and + 0 C 0 GV E0 0.0 00 AB VVUBL 0.0 Partition 0 AB ACBL 0.00 () Enclosure GV MCK0 GV K0 mushroom head Emergency stop pushbutton GV Mp0 0 /

References (continued) Enclosed thermal-magnetic motor circuit-breakers GV ME and accessories Assembly of a safety enclosure Assembly of a safety enclosure (conforming to standards IEC 0--, IEC 00 and IEC 0) Type of product Page Reference Enclosure Opposite GV MCpp Circuit-breaker / GV MEpp Undervoltage trip or INRS trip () / GV Apppp Latching mushroom head Stop pushbutton Opposite or GV AXppp GV K0 or GV K0 or GV K0 0 /

Dimensions, mounting Enclosed thermal-magnetic motor circuit-breakers GV ME Dimensions Surface mounting enclosure GV MC0p () 0 Surface mounting enclosure GV MCK0 () 0, Mounting Flush mounting enclosures GV MP0p (panel cut-out) GV MP0p GV MP0, MP0 GV MP0, MP0 Front plate GV CP 0,... a,, 0,,..., GV a MP0, MP0 MP0, MP0 0 /

Schemes Enclosed thermal-magnetic motor circuit-breakers GV ME Schemes GV MEpp /L /L /L /T /T /T Instantaneous auxiliary contacts GV AE GV AE GV AE0 or Instantaneous auxiliary contacts and fault signalling contacts GV AD00 GV AD00 GV AD00 GV AD00 Instantaneous auxiliary contacts Short-circuit signalling contacts GV AN GV AN0 GV AM () () () () 0 0 () () () () 0 Voltage trips GV AUppp GV ASppp GV AXppp D D C C D D Wiring diagram for undervoltage trip used on potentially dangerous machines, conforming to INRS E E 0 AgG max /L /L /L D D E 0 /T /T /T E /

Characteristics, references D.O.L. starters with manual control, with magnetic circuit-breaker, 0. to 0 kw Characteristics () Conforming to standards IEC 0-, IEC 0-, VDE 00-0 and EN 0 Degree of protection conforming to IEC 0 GV LC: IP GV NGC: IP 0 Operational voltage Ue GV LC: 0 V GV NGC: 00 V Material Polycarbonate () References Control by black rotary handle, padlockable in Off position (up to padlocks with Ø shank, to be ordered separately) 0 Rating In Breaking capacity Icu conforming to IEC 0-0/ 0 V 00/ V 0 V 00 V Magnetic tripping current Id ± 0 % Reference Weight A ka ka ka ka A kg. 00 00 00 00 In GV LC00 () 0.0. 00 00 00 00 In GV LC00 () 0.0 GV LC0pp 00 00 00 00 In GV LC00 () 0.0. 00 00 00 00 In GV LC00 () 0.0 0 00 00 0 0 In GV LC0 () 0.0 GV LC0pp 00 0 0 0 In GV LC0 () 0.0 00 0 0 0 In GV LC00 () 0.0 00 0 0 In GV NGC0.0 00 0 0 In GV NGC0.0 0 00 0 0 In GV NGC00.0 pp 0 00 0 0 In GV NGC00.0 00 0 0 In GV NGC0.0 Variants Starters with control by red rotary handle on yellow background Add the letter R to the references selected above. Example: GV LC00 becomes GV LC00R. GV LC0 Enclosure without circuit-breaker, with rotary handle mounted on cover Description Rating Reference Weight A kg Black rotary handle. GV LC0 0.00 GV NGC0 0.0 Red rotary handle on yellow background. GV LC0R 0.00 GV NGC0R 0.0 0 () Circuit-breaker characteristics: GV L: see pages / and / NG L () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, ketones, alcohol, aromatic GVAD or GVAM auxiliary contact block on the LH side and a GVAp trip on the /

Dimensions, scheme D.O.L. starters with manual control, with magnetic circuit-breaker, 0. to 0 kw Dimensions GV LC00 LC00 GV NGC0 NGC0 0 0, 0 Knock-outs or blanking plugs for cable glands Enclosure type At top At bottom ISO ISO GV LC x 0 or x x 0 or x GV NGC x 0 or x or x or x 0 x 0 or x or x or x 0 Scheme /L /L /L /T /T /T 0 /

Characteristics, references D.O.L. starters for motor control (). to kw, without isolating device Characteristics Conforming to standards IEC 0-- and IEC 0-, VDE 00-0, EN 0 Degree of protection conforming to IEC 0 IP : LE K IP : LEp D0 D IP : LEp D0 D Ambient air temperature Operation: - + 0 C Operating positions Material Same as that of the contactors Polycarbonate (): LE K and LEp D0 D Sheet steel: LEp D0 D References LE Dpp LE Dpp Non-reversing starters Standard power ratings of -phase motors 0-0 Hz in category AC- 0 V 0 V V 0 V 00 V 0 V 0 V 00 V 0 V Maximum current I the up to Basic reference, to be completed by adding the voltage code () Weight kw kw kw kw kw kw A kg... LE D0pp 0.0..... LE Dpp 0.0. 0 0 LE Dpp.0. LE Dpp.0... LE Dpp.0. 0 0 LE D0pp.0 0 0 0 LE D0pp.0. 0 LE Dpp.0 0 LE D0pp.0 LE Dpp.0 Reversing starters... LE K0pp.00. LE K0pp.00 LE D0pp ().00.. LE D0pp.00..... LE Dpp.00. 0 0 LE Dpp.0. LE Dpp.0... LE Dpp.00. 0 0 LE D0pp.0 0 0 0 LE D0pp.0. 0 LE Dpp.0 0 LE D0pp.00 LE Dpp.000 () Overload protection must be provided by a thermal overload relay, to be ordered separately, see pages /0 () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, Volts 0 0 0 0 0 00 0 a 0/0 Hz LE K B D E F M P U Q V N R LE, LE D B D E F FE M P U Q V N R () Selection according to the number of operating cycles, please consult your Regional Sales 0 Dimensions : page / Schemes : page / /0

References (continued) D.O.L. starters for motor control (). to kw, without isolating device Description Standard versions comprise: b For non-reversing starters: v green Start button I, v red Stop/Reset button O. LE DppA0 LE DppA0 b v v For reversing starters: LE K: - Start button A, - Start button E, - red Stop/Reset button. LE D0 D: - -position spring return selector switch I - II, - red Stop/Reset button O, LE D0 D: v - blue Reset button R. Variants (pre-assembled) Description Application the starter reference () No pushbuttons on cover green Start button I green Start button II red Stop/Reset button O LE D0 D LE D0 D LE D0 D A0 A LE DppA0 blue Reset button R LE D0 D LE K0 and K0 LE D0 D -position stay put selector switch ( I - O - II ) ( I : Automatic Start; O : Stop; II : Manual Start) blue Reset button R LE D0 D A0 A0 -position stay put selector switch O - I ( O : Stop; I : Manual Start) blue Reset button R LE D0 D A LE DppA LE DppA -position selector switch O - I spring return to centre position ( I : Manual start; O : Stop, stay put) blue Reset button R neutral terminal Fitted as standard on LE and LE D0 to D, LE and LE D0 to D starters ordered with V (M), 0 V (P) or 0 V (U) control supply Mounting of an LC D0 or D contactor in an enclosure identical to LE D () LE D0 D LE D0 D LE K0 and K0 LE D0 D LE D0 LE D Accessory (for customer assembly) Description Application Reference Weight kg Start pushbutton latching device for stay put operation (Start-Stop) () Example: LE D0FA0 () See dimensions page / A A T LE D0 D LA D00 0.00 Other versions Possible combinations of variants. 0 Schemes : page / /

Dimensions D.O.L. starters for motor control. to kw, without isolating device Dimensions LE D0 and D LE D0 and DppT LE D D and LE D0 D LE D0 D c 0 c c LE D LE D c Standard version. Standard version. 0 Standard version Variant A0 Variant A0 Variant A0 0 Variant A0. Variant A0.. Variant A0 Variant A0 Variant A0 0 Variant A Variant A 0 Variant A Variant A 0 c 0 0 c 0 LE K0 and K0 0 0 LE D0, LE D and LE D0 D LE D0 and D 0 c 0 c LE D LE D c Standard version Standard version Variant A0 Variant A0 0 Variant A0 Variant A0 Variant A Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE D0 and D x 0 x or x x 0 LE D D and LE D0 D x 0 or x x or x x 0 or x LE D0 x and x x 0 and x x and x x 0 and x LE D0 D, LE D0 and D x and x x 0 and x x and x x 0 and x LE or LE D0 and D x and x x 0 and x 0 x and x x 0 and x 0 LE K x and x x 0 x and x x 0 c References : pages /0 and / Schemes : page / /

Schemes D.O.L. starters for motor control. to kw, without isolating device Schemes LE D0 D LE D0 D Variant A0 or A0 KM L U L V W L A B LE K0, K0 LE K0, K0 Variant A0 L L L A I O KM KM A A A B A O Remote control l KM KM A A R O KM KM Remote control KM KM U V W B KM KM KM A A A A KM B KM KM KM A A A A KM LE D0 D LE D0 D LE D0 D, LE D0 D with variants A0 or A0 L L L A A R KM KM S I II O Remote control ll KM KM KM KM KM KM KM KM KM A A KM KM A A KM U V W B A A B A A Connections A B 0 V, 0 V, 0 V LE K, LE and LE D0 and D L Neutral LE and LE D D L Neutral terminal 0 V, 00 V, V, 0 V All products L L Other voltages LE and LE D0 D Terminal Terminal LE K, LE and LE D0 and D Direct connection 0 References : pages /0 and / Dimensions : page / /

Characteristics, references D.O.L. starters for motor control (). to kw, with isolating device Characteristics Conforming to standards IEC 0-- and IEC 0-, VDE 00-0, EN 0 Degree of protection conforming to IEC 0 IP : LEp K IP : LEp D0 D IP : LEp D0 D0 Ambient air temperature Operation: - + 0 C Operating positions Material Same as that of the contactors Polycarbonate (): LEp K and LEp D0 D Sheet steel: LEp D0 D0 References LE Dpp Non-reversing starters Standard power ratings of -phase motors 0-0 Hz in category AC- 0 V 0 V 0 V 00 V V 0 V 00 V 0 V 0 V Maximum current I the up to by the customer Size Type am Basic reference, to be completed by adding the voltage code () Weight kw kw kw kw kw kw A A kg... 0 x 0 LE K0pp.0. 0 x LE K0pp.0 or LE D0pp ().0.. 0 x LE D0pp.0.... 0 x LE Dpp.0. 0 0 x 0 LE Dpp.00. 0 x LE Dpp.00... x LE Dpp.0. 0 0 x 0 LE D0pp.0 0 0 0 x LE D0pp.0. 0 x 0 LE Dpp.0 0 x 0 LE D0pp ().00 0 LE Dpp Reversing starters... 0 x 0 LE K0pp.00. 0 x LE K0pp.00 or LE D0pp ().0. 0 x LE D0pp.0.... 0 x LE Dpp.0. 0 0 x 0 LE Dpp.00. 0 x LE Dpp.0... x LE Dpp.00. 0 0 x 0 LE D0pp.0 0 0 0 x LE D0pp.00. 0 x 0 LE Dpp.0 0 x 0 LE D0pp.000 () Overload protection must be provided by a thermal overload relay, to be ordered separately, see pages /0 () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, ketones, alcohol, aromatic Volts 0 0 0 0 0 00 0 a 0/0 Hz LEp K B D E F M P U Q V N R LEp D B D E F FE M P U Q V N R 0 Dimensions: page / Schemes: page / /

References (continued) D.O.L. starters for motor control (). to kw, with isolating device LE DppA0 Description Standard versions comprise: b For non-reversing starters: v LE K and LE D0 D - green Start button I, - red Stop/Reset button O. v LE D0 - no pushbuttons on cover b v v For reversing starters: LE K : - Start button A, - Start button E, - red Stop/Reset button. LE D0 D : - -position spring return selector switch I - II, - red Stop/Reset button O, LE D0 to D0: v - no pushbuttons on cover. Protection Power circuit Control circuit LE and LE K -pole isolating device None LE and LE D0 D -pole isolating device + additional pole LE and LE D D0 -pole isolating device + circuit-breaker GB CB0 Variants (pre-assembled) Description Application the starter reference () No pushbuttons on cover LE D0 D LE D0 D A0 LE DppA0 green Start button I green Start button II red Stop/Reset button O LE D0 D0 A blue Reset button R LE D0 D0 LE K0 and K0 LE D0 D LE D0 D0 neutral terminal Fitted as standard on LE D D0, LE D D and LE D0 D0 starters ordered with 0 V (M), 0 V (P) or 0 V (U) control supply LE K0 and K0 LE D0 D0 LE K0 and K0 LE D0 D LE D0 D0 A0 A Accessory (for customer assembly) Description Application Reference Weight kg Start pushbutton latching device for stay put operation (Start-Stop) () See previous page () Example: LE D0FA0 LE D0 D LA D00 0.00 Other versions Possible combinations of variants. 0 Dimensions: page / Schemes: page / /

Dimensions D.O.L. starters for motor control. to kw, with isolating device Dimensions LE K0 and K0, LE K0 and K0 0 0 c 0 () LE D0 D, LE D0 D c 0 c c LE K LE K LE D LE D Standard version Standard version. Variant A0 Variant A0 () For LE only Variant A0.. LE D0 D LE D0 D0, LE D0 a- 00 (), 0 c xmx c c a LE D LE D Standard version 0 LE D0, D0, D 00 Standard version Variant A0 0 LE D0 00 Variant A0 Variant A0 0 LE D0 00 Variant A Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE and LE D0 D x 0 or x or x or x 0 0 c x 0 or x or x or x 0 LE D0 D x 0 or x x 0 or x LE D0 and LE D0 x and x x 0 and x x and x x 0 and x LE D0 D, LE D0 and D x and x x 0 and x x and x x 0 and x LE D0 and LE D0 x and x x 0 and x 0 x and x x 0 and x 0 LE K and LE K x and x x 0 x and x x 0 a-0 a a+, 0 References : pages / and / Schemes : page / /

Schemes D.O.L. starters for motor control. to kw, with isolating device Schemes LE K0, K0 LE D0 D0 Q L L L A LE K0, K0 LE D0 D LE D0 D LE D0, LE D0 D with variant A0 or A0 A Q Q A F Q A F Q KM U V W B I O KM A A KM B I O KM KM A A B l O KM KM A A B O Remote control l KM A A KM LE K0, K0 LE K0, K0 Variant A0 L L L A A Q Q R O Remote control KM KM KM KM KM KM U V W B KM KM LE D0 LE D0 LE D0 D LE D0 D0 A A KM KM A A KM B A A A A KM Q L L L A Q Q O A F Q KM KM S I II O Remote control ll KM KM KM KM KM KM KM KM KM A A KM KM A A KM U V W B Connections A B 0 V, 0 V, 0 V LE and LE K, LE and LE D0 and D L Neutral LE D D0, LE D D and LE D0 D0 L Neutral terminal 0 V, 00 V, V, 0 V All products L L Other voltages LE and LE D0 D Terminal Terminal LE and LE D0 D0 Direct connection A A B A A 0 References : pages / and / Dimensions : page / /

Characteristics, references D.O.L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--, IEC 0-, VDE 00-0 and EN 0 Degree of protection conforming to IEC 0 IP Ambient air temperature Operation: - to + 0 C Operating positions Same as for the TeSys K contactors Material Self-extinguishing ABS References Non-reversing starters Starter LE M, combined with short-circuit protection components, provides type or type coordination, depending on the type of devices used. Standard power ratings of -phase motors 0-0 Hz in category AC- 0 V 0 V 0 V 0 V 00 V V Setting range of thermal overload relay LR K () Basic reference, to be completed by adding the voltage code () Weight kw kw kw kw A kg 0. 0. 0. 0. 0. 0. LE Mpp0 0.00 0. 0. 0. 0. 0.. LE Mpp0 0.00 0. 0. 0. 0... LE Mpp0 0.00 0. 0.. 0... LE Mpp0 0.00 0. 0..... LE Mpp0 0.00. 0..... LE Mpp 0.00... LE Mpp 0.00... LE Mpp 0.00 LE Mpppp.. 0 LE Mpp 0.00... LE Mpp 0.00 Description Variant Replacement part b The standard version comprises: v TeSys contactor LC Kpp, v TeSys thermal overload relay LR K, v green Start button I, v red Stop/Reset button O/R, v yellow operating indicator. b Control may be pulsed or maintained. b An earth terminal and a neutral terminal are provided on the bottom of the enclosure. b For safey applications, see enclosed starters: GV MC, LG K, LG D, LG K, LG D, LJ K, LG K and LJ K. Starter without thermal overload relay LR K Delete the last digits of the starter references selected above. Example: LE Mpp Description Basic reference, to be completed by adding the voltage code () Weight kg Contactor LC KppA0 0.0 0 () For characteristics of TeSys K contactor, see pages /0 to / For characteristics of TeSys thermal overload relay LR K, see pages /0 and / The codes indicated below therefore correspond to the power circuit voltage Volts 0 0 0 0 00 0 a 0/0 Hz Code B M P U Q V N R Example: 0/00 V -phase supply, kw motor: LE MQ Dimensions : page / Schemes : page / /

Dimensions, schemes D.O.L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Dimensions LE M () 0 0 0 ("/) Knock-outs or blanking plugs for cable glands Enclosure type At top At bottom PG ISO PG ISO LE M x to x x 0 or x x to x x 0 or x I Schemes LE M O/R L L L T T T A A Reset/OR /L U /L V M /L KM I W Choice of type of control built into the product Control by latching pushbuttons Control by spring return pushbuttons A B O A KM H A KM Connection A B 0 V, 0 V, 0 V L Neutral 0 V, 00 V, V, 0 V L L Other voltages Terminal Terminal A B I O/R A KM H A KM 0 References : page / /

Characteristics, references D.O.L. starters for motor control, 0. to. kw with thermal magnetic circuit-breaker and contactor 0 Characteristics Conforming to standards IEC 0--, IEC 0-, VDE 00-0 and EN 0 Degree of protection conforming to IEC 0 IP Ambient air temperature Operation: - to + 0 C Operating positions Same as for the TeSys K contactors Material Polycarbonate () References Standard power ratings of -phase motors 0-0 Hz in category AC- 0 V 00/ 0 V 00 V 0 V V Setting range of thermal trips Fixed magnetic tripping current Irth Basic reference, to be completed by adding the voltage code () Weight kw kw kw kw kw A A kg 0. 0. 0. 0. 0. 0. 0. 0. 0. 0.... LE GVME0Kpp.0 0. 0. 0....... LE GVME0Kpp.0 0. 0........ LE GVME0Kpp.0 LE GVMEppKpp Variants........... LE GVME0Kpp.0... 0 LE GVMEKpp.0 0 LE GVMEKpp.0 Description Weight to the starter reference () kg Neutral terminal A LE GVMEK Description Reference Weight kg (references of combination motor starters for customer assembly, see pages / and /) LE GVMEK 0.0 0 Accessories (to be ordered separately) Description Padlocking device () to padlocks for GV ME operator (padlocking Ø to mm is only possible in the O position) Mushroom head Stop pushbutton Ø 0 mm, red Sealing kit Sold in lots of Unit reference Weight kg GV V0 0.0 Spring return () GV K0 0.0 Latching () IP Key release, GV K0 0.0 key n Turn to release GV K0 0. GV K0 () 0.0 IP for 0 GV E0 0.0 temperature between + C and + 0 C IP for 0 GV E0 0.0 temperature between - 0 C and + 0 C () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, Volts 0 0 0 0 0 00 0 a 0/0 Hz Item B D E F M P U Q V N R () Example: LE GVME0KFA Dimensions : page / Schemes : page / /0

Dimensions, schemes D.O.L. starters for motor control, 0. to. kw with thermal magnetic circuit-breaker and contactor Dimensions LE GVMEK 0 Knock-outs or blanking plugs for cable glands Enclosure type At top At bottom ISO ISO LE GV x 0 or x x 0 or x Schemes LE GVMEK 0 A L L L Q Q O External control I KM KM KM A B A Connections A B 0 V, 0 V, 0 V L Neutral 0 V, 00 V, V, 0 V L L Other voltages Terminal Terminal 0 References : page /0 /

Characteristics, references Star-delta starters. to kw, without isolating device () Characteristics Conforming to standards IEC 0-- and IEC 0-, VDE 00-0, EN 0 Degree of protection conforming to IEC 0 IP : LE K IP : LE D0 D IP : LE D0 D0 Ambient air temperature Operation: - to + 0 C Operating positions Material References Same as that of the contactors Polycarbonate (): LE K and LE D0 D Sheet steel: LE D0 D0 Maximum operating rate: LE K: starts/hour and LE-D: 0 starts/hour. Maximum starting time: 0 seconds. LE D: an LAD S timer imposes a delay of 0 ms ± ms on the delta contactor at time. Standard power ratings of squirrel cage motors Mains voltage - delta connection Basic reference, to be completed by adding the voltage code () Weight 0 V 0/00 V V 0 V kw kw kw kw kg... LE K0pp.0... LE K0pp.0 or LE D0pp ().0 LE Dpp. LE Dpp.0. LE Dpp.0 0 0 0 LE Dpp.0. LE D0pp.0 0 LE D0pp.0 LE D0pp.000 0 0 0 LE Dpp.00 LE D0pp.00 pages /0 () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, Volts 0 0 0 0 0 00 0 a 0/0 Hz LE K B D E F M P U LE D B D E F FE M P U Q V N R () Selection according to dimensions and the number of operating cycles, please consult your 0 Dimensions : page / Schemes : page / /

References (continued) Star-delta starters. to kw, without isolating device Description The standard version comprises: b LE K and LE D0 D: v green Start button I, v red Stop/Reset button O. LE DppA0 b LE D0 D0: v no pushbuttons on cover. Variants (pre-assembled) Description Application the starter reference () No pushbuttons on cover LE D0 D A0 green Start button I red Stop/Reset button O LE D0 D0 A0 blue Reset button R LE D0 D0 A0 neutral terminal Fitted as standard on starters LE D and D0 LE K0 and K0 LE D0 D0 A LE DppA0 Mechanical interlock Fitted as standard on starters LE K and LE D0 D () Example: LE D0FA0 LE D0 to D0 A Other versions Possible combinations of variants. 0 Schemes : page / /

Dimensions Star-delta starters. to kw, without isolating device Dimensions LE K0, K0 0 0 LE D0 D c 0 LE D0 and D0 c Standard version. Variant A0 Variant A0. LE D0 D0 a - b () b +, b - 0 b - c c c +, a - 0 a a +, c c LE a b LE D0 D, D0 Standard version 0 D0 00 00 Standard version 0 Variant A0 D 00 00 Variant A0 Variant A0 D0 00 00 Variant A0 Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE D0 D x 0 or x or x or x 0 LE D0 x x x, x and x LE D0 x x 0 x, x and x x 0 or x or x or x 0 x, x 0 and x x 0, x 0 and x LE D0 x x 0 x and x x 0 and x 0 LE K x and x x 0 x and x x 0 0 References : pages / and / Schemes : page / /

Schemes Star-delta starters. to kw, without isolating device Schemes LE K0 and K0 L L L A U V W O KM KM KM U V W U V W I KM KM KM KM U V W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). T B A A T KM A A Y A A A KM KM A L LE D0 D0 LE D0 D LE D0 D0 L L L A A U V W O KM KM KM I KM Remote control I KM U U V V W W U V W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). B KM KM KM KM KM Note : A A Y A A L A KM KM KM KM A B KM KM KM A A Y A A KM KM A KM KM L A LE D and D0 L L L U V W A KM KM KM U U V V W W U V W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). B Remote control l Connections A B 0 V, 0 V, 0 V LD0 and D L Neutral LE D to D0 L Neutral terminal 0 V, 00 V, V, 0 V All products L L Other voltages LE D0 D Terminal Terminal LE K and LE D0 D0 Direct connection F KM KM KM KM KM A A Y KM KM A A L KM KM KA A A KA KM A A 0 References : pages / and / Dimensions : page / /

Characteristics, references Star-delta starters (). to kw with isolating device Characteristics Conforming to standards IEC 0-- and IEC 0-, VDE 00-0, EN 0 Degree of protection conforming to IEC 0 IP : LE D0 D IP : LE D D0 Ambient air temperature Operation: - to + 0 C Operating positions Material References Same as that of the contactors Polycarbonate (): LE D Sheet steel: LE D Maximum operating rate: 0 starts/hour. Maximum starting time: 0 seconds. An LA DS timer imposes a delay of 0 ms ± ms on the delta contactor at the Standard power ratings of squirrel cage motors. Mains voltage - Delta connection 0 V 0 V 00 V V 0 V by the customer Size Type am Basic reference, to be completed by adding the voltage code () Weight kw kw kw kw A kg... 0 x 0 LE D0pp.00. 0 x LE Dpp.00. x 0 LE Dpp.0 LE Dpp 0 0 0 x LE Dpp.0. x 0 LE D0pp.00 0 x LE D0pp.000 0 0 LE D0pp.00 pages /0 () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, Volts 0 0 0 0 0 00 0 0/0 Hz B D E F FE M P U Q V N R 0 Dimensions: page / Schemes: page / /

References (continued) Star-delta starters. to kw, with isolating device Description The standard version comprises: b LE D0 D: v green Start button I, v red Stop/Reset button O. b LE D D0: v no pushbuttons on cover Protection Power circuit Control circuit LE D0 and D -pole isolating device + additional pole LE D LE D0 -pole isolating device + circuit-breaker GB CB0 LE DppA0 Variants (pre-assembled) Description Application the starter reference () No pushbuttons on cover LE D0 D A0 green Start button I red Stop/Reset button O LE D D0 A0 blue Reset button R LE D0 LE D0 A0 neutral terminal LE D0 LE D0 A LE DppA0 Mechanical interlock Fitted as standard on starters LE D0 D LE D D0 A () Example: LE D0FA0 0 Dimensions: page / Schemes: page / /

Dimensions Star-delta starters. to kw, with isolating device Dimensions LE D0 D LE D c 0 0 c Standard version. Variant A0 Variant A0. LE D0 D0 a- b () b+, b-0 b- xmx c a-0 a a+, LE a b c D0, D0 00 00 D0 00 00 Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE D0 D x 0 or x or x or x 0 LE D x x x, x and x LE D0 x x x, x and x LE D0 x x 0 x, x and x x 0 or x or x or x 0 x 0, x and x x 0, x and x x 0, x 0 and x LE D0 x x 0 x and x x 0 and x 0 0 References : pages / and / Schemes : page / /

Schemes Star-delta starters. to kw, with isolating device Schemes LE D0 D Q /L /L /L A Q Q KM KM KM U V W O l KM U V W KM U U V V W W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end) B KM KM KM A A A A KM KM KM KM A A LE D D0 Q /L /L /L KM KM KM U V W A F Q U V W U V W Remote Ð S control l KM KM U V W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end) B KM KM KM A A A A KM KM KM KM A A Connections A B 0 V, 0 V, 0 V LE D0 and D L Neutral LE D LE D0 L Neutral terminal 0 V, 00 V, V, 0 V All products L L Other voltages LE D0 D Terminal Terminal LE D D0 Direct connection 0 References : pages / and / Dimensions : page / /

References Replacement parts for starters without isolating device 00_ Heads for Start and Stop/Reset pushbuttons Description For use on Unit reference Weight kg Flush, green I () LE D0...D ZB AA 0.0 000_ ZB AA Projecting, red O () LE D0...D ZB AL 0.0 Adaptation kit for head ZB AL LE D0 and D LAD 0 0.00 LE D...D LAD 0 0.00 ZB AL Heads for Reset pushbuttons Flush, blue R () LE D0...D ZB AA0 0.0 00_ + ZBA () 0.00 Adaptation kit for head ZB AA0 + ZBA LE D0 and D LAD 0 0.00 LAD 0 LE or LE D...D LAD 0 0.00 LE, LE, LE or LE D0...D LAD T 0.00 00_ Heads for selector switches -position stay put LE D0...D ZB AD 0.0 00_ ZB ADp -position stay put LE D0...D ZB AD 0.0 -position spring return to centre LE D0...D ZB AD 0.0 Contact blocks N/O spring return LE D0...D ZEN L 0.00 00_ N/C spring return LE D0...D ZEN L 0.00 Mounting for contact block LE D0 and D LAD 00 0.00 LEp D...D () LAD 0 0.0 0 LAD 0 /0

References (continued) Replacement parts for starters without isolating device Empty enclosures for D.O.L. starters without isolating device Designed for use with Head(s) mounted on cover Reference Weight kg LE D0 and D Without DE DSA0 0.00 DE DSA0 0.00 DE DSA0 projecting red head O DE DS 0.00 switch DE DSA 0.00 DE DSA0 LE D...D Without DE DSA0 0.00 DE DSA0 0.00 DE DS projecting red head O DE DS 0.00 switch DE DSA 0.00 DE DSA 0 /

References Star-delta starters () 0 to kw, without isolating device Star-delta starters Maximum operating rate: starts/hour. Maximum starting time: 0 seconds Standard power ratings of squirrel cage motors Mains voltage - delta connection Basic reference, to be completed by adding the voltage code () () Weight 0 V 0 V V 0 V kw kw kw kw kg 0 0 0 LE Fpp.00 00 00 00 0 LE Fpp.000 0 0 0 0 LE Fpp 0.00 0 0 0 LE F0pp 0.000 LE F00pp.000 Enclosure LE F F00 Metal, degree of protection IP No pushbuttons on cover LE F F00 LE Fppppp Connections LE F F00 Pre-wired power and control circuit connections Variants (pre-assembled) Description green Start button I red Stop/Reset button O For use on LE F F00 to the starter reference() A0 pages / and / Volts 0 0/0 0 0 0/00 00 0/0 Hz E F M P U Q V N For other voltages, see pages /0 () Example: LE FMA0 Other versions Possible combinations of variants. 0 Dimensions : page / Schemes : page / /

Dimensions, schemes Star-delta starters 0 to kw, without isolating device Dimensions LE Fppp a- b () b+, b-0 b- xmx c c a-0 a a+, LE a b () c c Knock-outs or blanking plugs for cable glands F, F 00 00 0 Type of enclosure At top At bottom F 00 00 0 LE F, F x P x P and x P F0, F00 00 000 0 LE F 00 Schemes LE Fppp L L L F KM: KM KM KM U U V V W W U U V V W W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end) F O Remote control l KM KM KM KM () () KM KM KA F KM A KM A KA A KM A KM: A A A A Note : 0 References : page / /

References Equipment for control in utilisation category AC-() (), without isolating device 0 References Operational current up to Minimum c.s.a. of phase conductors Fuses to be am gg For use with relay LR D or kit LA D (to be ordered separately) Basic reference, to be completed by adding the voltage code () Weight A mm A A kg. LA D () LE Dpp 0.0.. 0 LR D () LE Dpp 0.0. LR D () LE Dpp.0 LE D LA D0 () LE Dpp.0 0 0 0 LE D0ppA0 ().0 0 LR D () LE D0pp.0 LE DppA0 () 0 LR D () LE Dpp.0.0 0 00 LR D () LE D0pp.0 LE D0 00 00 LE D0ppA0 ().0 Enclosure LE D Double insulated, degree of protection IP LE D Double insulated, degree of protection IP LE D0...D0 Metal, degree of protection IP Control ( pushbuttons mounted on enclosure cover) No pushbuttons on cover LE D D0 LE DpppppA0 green Start button I red Stop/Reset button O Connections LE D D0 Pre-wired control circuit connections to walls, ceilings, in cable racks or ducting, laid singly, ambient temperature y () Order the required LR D () Control circuit voltage 0/0 Hz 0/0 V (code M) or 0/00 V (code Q () As protection is provided by type gg fuses only, the Stop function normally provided by the thermal overload relay (where am type fuses are used) can be obtained by means of kit LA Dpp 0 Dimensions : page / Schemes : page / /

References (continued) Equipment for control in utilisation category AC-() (), without isolating device Variants (pre-assembled) Description Application the starter reference () No pushbuttons on cover LE D and D A0 blue Reset button R LE D D0 A0 green Start button I and red Stop button O with N/C contact (for distribution circuits without thermal overload relay) LE D and D A0 -position selector switch O-I ( O : Stop; I : Manual Start) blue Reset button R Knock-outs for x mm plastic cable glands (instead of x mm plastic glands) LE D LE D A A0 neutral terminal (for -phase + N circuits) LE D D0 A Accessories (for customer assembly) Description Start pushbutton latching device for stay put operation (Start-Stop) Kits to provide Stop function For use on Reference Weight kg LE D D LA D00 0.00 LE D LA D 0.00 LE D LA D0 0.00 Miniature control circuit fuse holder size x 0, A/0 V Fuse supplied LE D LA D 0.00 LE D LA D 0.0 Pilot light with neon bulb, red lens and locking ring 0 V LE D and D LA D 0.00 0 V LE D and D LA D 0.00 0, V LE D and D LA D 0.00 front-mounting block of auxiliary contacts, LE D D0 LA DNpp 0.00. in cable racks or ducting, laid singly, ambient temperature y () Order the required LR D Example: LE DMA0 Other versions Possible combinations of variants. 0 Schemes : page / /

Dimensions D.O.L. starters and equipment, without isolating device Dimensions LE D LE D 0 0 0 0 LE D0, D LE D0 0 0 () 0 c () 0 for LE Dppppp Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom LE D x P x P LE D x P and x P x P LE D0 and LE D x P and x P x P and x P LE D0 x P and x P x P and x P 0 References : pages / and / Schemes : page / /

Schemes D.O.L. starters and equipment, without isolating device Schemes D.O.L. starters and equipment for control in category AC- LE D D0, LE DpppppA0 LE D KM /L U /L LE D D0 V W /L KM/ N I KM/ O KM KM A A LE DpppppA0, LE DpppppA0 KM/ KM/ l N KM/ O KM KM A A Remote control N KM/ O l KM KM A A 0 References : pages / and / Dimensions : page / /

References Equipment for control in utilisation category AC- () (), with isolating device References Operational current up to Minimum c.s.a. of phase conductors by the customer Size Type am gg For use with relay LR D or kit LA D (to be ordered separately) Basic reference, to be completed by adding the voltage code () Weight A mm A A kg. 0 x LA D0 () LE Dpp.0 LE D.. 0 x 0 LR D () LE Dpp.0 0. 0 x 0 LA D0 () LE Dpp.00 0. 0 x LR D () LE Dpp.00 0 0 x 0 LE D0ppA0 ().0 0 x 0 LR D () LE D0pp.0 LE D0 x LE DppA0 ().0 x 0 LR D () LE Dpp.0 0 x 00 LR D () LE D0pp ().00 00 x 00 LE D0pp ().00 Enclosure LE D and D Double insulated, degree of protection IP Control ( pushbuttons mounted on enclosure cover) LE D0 D0 Metal, degree of protection IP LE D D green Start button I red Stop/Reset button O No pushbuttons on cover Isolating device with external operator LE Dppppp A0 LE D0 LE D and D LE D0 D0 -pole isolator + additional pole -pole isolator and circuit breaker GB CB0 Connections LE D D0 Pre-wired power and control circuit connections in cable racks or ducting, laid singly, ambient temperature y () Order the required LR D () Control circuit voltage 0/0 Hz 0/0 V (code M) or 0/00 V (code Q () As protection is provided by type gg fuses only, the Stop function normally provided by the thermal overload relay (where am type fuses are used) can be obtained by means of kit LA D0 0 Dimensions : page /0 Schemes : page / /

References (continued) Equipment for control in utilisation category AC- () (), with isolating device Variants (pre-assembled) Description For use on the starter reference() No pushbuttons on cover LE D and D A0 blue Reset button R LE D D0 A0 green Start button I and red Stop button O with N/C contact (for distribution circuits without thermal overload relay) LE D and D A0 neutral terminal (for -phase + N circuits) LE D D0 A Accessories (for customer assembly) Description Start button latching device for stay put operation (Start-Stop) Kit to provide Stop function For use on Reference Weight kg LE D D LA D00 0.00 LE D and D LA D0 0.00 Miniature control circuit fuse holder size x 0, A/0 V Fuse supplied Pilot light with neon bulb, red lens and locking ring LE D and D LA D 0.0 0 V LE D and D LA D 0.00 0 V LE D and D LA D 0.00 0, V LE D and D LA D 0.00 front-mounting block of auxiliary contacts, LE D D0 LA DNpp 0.00 in cable racks or ducting, laid singly, ambient temperature y () Order the required LR D () Example: LE DMA0 Other versions Possible combinations of variants. 0 Schemes : page / /

Dimensions D.O.L. starters and equipment, with isolating device Dimensions LE D, D LE D0, D c c 0 0 c c () LE c c D D () c c for LE Dppppp b G a H LE D0 a- b () b+, b-0 b- xmx c c a-0 a a+, Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom LE D x P x P LE D x P and x P x P LE D0 x P and x P x P and x P LE D x P and x P x P and x P LE D0 x P and x P x P and x P 0 References : pages / and / Schemes : page / /0

Schemes D.O.L. starters and equipment, with isolating device Schemes D.O.L. starters and equipment for control in category AC- LE D D0, LE DpppppA0 LE D and D Q KM /L /L /L Q/ 0 Q N l Q O KM KM A U V W Q/ A LE D0 and D Q/ l F Q O KM LE D0, LE DpppppA0 and DpppppA0 Q/ F Q Remote control O l KM N Q/ KM A A N Q/ KM A A 0 References : pages / and / Dimensions : page /0 /

References integral contactor breakers and reversing contactor breakers, for customer assembly Empty metal enclosure Type of enclosure Degree of protection IP with drillings for door interlock mechanism (interlock not supplied), for customer assembly () For use on integral Door interlock mechanisms (IP ) Type Non-adjustable Reference Weight kg LD LD or LD LD DE LT.0 For use on enclosure DE LT (LD) Colour of knob Reference Weight kg Red LA LC0 0.00 Black LA LC 0.00 DE LT DE LT (LD) Red LA LC0 0.00 Black LA LC 0.00 () cable glands (to be ordered separately): for number and diameters, see page / 0 Dimensions : page / /

Dimensions, mounting of accessories integral contactor breakers and reversing contactor breakers, for customer assembly Empty metal enclosure, degree of protection IP 0 Number of blanked-off cable entries for addition of cable glands At Cable Ø For cable gland top bottom min. max. N Type 0 M 0 M Non-adjustable door interlock mechanisms LA LCp and LA LCp For mounting on LD LDp0 and LD LDp0 () LD LDp0 LD LDp0 0 0 0 0 0 (LD) (LD) Door drillings 0 0 References : page / /

Characteristics integral contactor breakers and reversing contactor breakers Type integral Number of poles Rated operational current (Ie) A in AC- Rated operational voltage (Ue) V 0 Electrical durability, AC- at V. million operating cycles Mechanical durability at Uc million operating cycles Maximum operating rate a 00 operating cycles/hour at ambient temperature y C c With converter 00 operating cycles/hour Environment Conforming to standards IEC: 0-, 00-, 0-, 0--, 0-- VDE: 000, 00, 0, 00, 0,, 00 BS:,, NEN, NBN Protective treatment Ambient air temperature around the device Vibration resistance Permissible acceleration Shock resistance Permissible acceleration ASE, ASEFA, ASTA, BV, CSA, DEMKO, DNV, GL, NEMKO, NKK, ÖVE, RINA, SCC, SETI, UL, USSR, LROS, PTB, SEMKO TH a Operation C - 0 + 0 Storage C - 0 + 0 c () Operation C - + 0 Storage C - + 0 00 Hz Energised state: gn De-energised state: gn Impulse duration: ms Energised state: gn De-energised state: gn Degree of protection Conforming to IEC and IP 0B Conforming to VDE 00 Flame resistance Conforming to IEC 0--, NF C 0- and the requirement of -- (JO NC of st and //) and conforming to UL - V0 and NF T -0 Maximum operating altitude Without derating m 000 Operating positions (without derating) In relation to normal vertical mounting plane From main axis (left-right tilt) Control circuit characteristics Rated control circuit voltage (Uc) Voltage limits at y C Average consumption at 0 C and at Uc a 0 Hz V 0 a 0 Hz V 00 c With converter V,, 0 Operating 0.. Uc Drop-out 0. 0. Uc a Inrush VA (0 Hz), 0 (0 Hz) Sealed VA (0 or 0 Hz) c () Inrush W 00 for 0 ms Sealed W Heat dissipation a 0 Hz W (0 Hz) (0 Hz) Operating time () at 0 C and at Uc a 0/0 Hz C ms O ms 0 c () C ms 0 O ms () The closing time C is measured from the moment the coil supply is switched on to initial 0 References : pages / to / / Dimensions : page /0 Schemes : page /