1 Preventa Machine Safety Products Catalog Supplement Safety Relay Modules
2 2
3 Contents Preventa safety relay modules Selection guide 2 Electrical Ratings 6 Types XPSAC and XPSAXE For Emergency stop and switch monitoring 8 Types XPSAV, XPSABV and XPSATE For Emergency stop and switch monitoring 2 Types XPSBA, XPSBCE and XPSBF For electrical monitoring of two-hand control systems 22 Types XPSECME and XPSECP For increasing the number of safety contacts 30 Dimensions 34 Product ratings and levels Reliability values according to standards EN/ISO and EN/IEC
4 Selection guide Preventa safety relay modules Applications Modules For Emergency stop and switch monitoring Maximum achievable safety level PL e/category 4 conforming to EN/ISO SILCL 3 conforming to EN/IEC 6206 PL e/category 4 conforming to EN/ISO SILCL 3 conforming to EN/IEC 6206 Conformity to standards EN/IEC , EN 088/ISO 49, EN/ISO 3850, EN/IEC , EN/IEC EN/IEC , EN 088/ISO 49, EN/ISO 3850, EN/IEC , EN/IEC Product certifications UL, CSA, TÜV UL, CSA, BG Number of circuits Safety 3 N.O. 3 N.O. Additional solid-state output for signalling to PLC relay output for signalling to PLC Display 2 LEDs 2 LEDs Supply voltage a and 24 V c 48 V a 5 V a 230 V a a and 24 V c Synchronisation time between inputs Unlimited Unlimited Input channel voltage 24 V/48 V version a and 24 V c / 48 V a 24 V c / 24 V/48 V or 0 V/20 V/230 V version 5 V a / 230 V Module type XPSAC XPSAXE Pages 8 8 2
5 Selection guide (continued) Preventa safety relay modules PL e/category 4 (instantaneous safety outputs) and PL d/category 3 (time delay safety outputs) conforming to EN/ISO 3849-, SILCL 3 (instantaneous safety outputs) and SILCL 2 (time delay safety outputs) conforming to EN/IEC 6206 PL e/category 4 conforming to EN/ISO 3849-, SILCL 3 conforming to EN/IEC 6206 PL e/category 4 (instantaneous safety outputs) and PL d/category 3 (time delay safety outputs) conforming to EN/ISO 3849-, SILCL 3 (instantaneous safety outputs) and SILCL 2 (time delay safety outputs) conforming to EN/IEC 6206 EN/IEC , EN/ISO 3850, EN 088/ISO 49, EN/IEC , EN/IEC EN/IEC , EN 088/ISO 49, EN/ISO 3850, EN/IEC , EN/IEC EN/IEC , EN/IEC , EN/IEC , EN/ISO 3850, EN 088/ISO 49 UL, CSA, TÜV UL, CSA, TÜV UL, CSA, BG 2 N.O. instantaneous + 3 N.O. time delay 3 N.O. instantaneous + 3 N.O. time delay 2 N.O. instantaneous + N.O. time delay 4 solid-state outputs for signalling to PLC 3 solid-state outputs for signalling to PLC 4 LEDs LEDs 3 LEDs a and 24 V c 5 V a 230 V a 24 V c 24 V c 75 ms (automatic start) Unlimited or.5 s (depending on wiring) Unlimited 24 V c / 24 V c / 24 V c / 48 V a / 48 V XPSATE XPSAV XPSABV
6 Selection guide (continued) Preventa safety relay modules Applications Modules For electrical monitoring of two-hand control stations Maximum achievable safety level PL c/category conforming to EN/ISO Conformity to standards EN/IEC , EN/IEC , EN/IEC , EN 574 type III A/ISO 385 PL e/category 4 conforming to EN/ISO 3849-, SILCL 3 conforming to EN/ IEC 6206 EN/IEC , EN/IEC , EN/IEC , EN 574 type III C/ISO 385 PL e/category 4 conforming to EN/ISO 3849-, SILCL 3 conforming to EN/ IEC 6206 EN/IEC , EN/IEC , EN/IEC , EN 574 type III C/ISO 385 Product certifications UL, CSA, TÜV UL, CSA, BG UL, CSA, TÜV Number of circuits Safety N.O. 2 N.O. 2 N.O. Additional N.C. N.C. 2 solid-state outputs for signalling to PLC Display 2 LEDs 3 LEDs 3 LEDs Supply voltage a and 24 V c 5 V a 230 V a a and 24 V c 5 V a 230 V a 24 V c Synchronisation time between inputs 500 ms 500 ms 500 ms Input channel voltage 24 V/48 V version 24 V c / 24 V c / 24 V c / 5 V/230 V version 24 V a / 24 V Module type XPSBA XPSBCE XPSBF Pages
7 Selection guide (continued) Preventa safety relay modules Applications Modules For increasing the number of safety contacts Functions Allows additional safety contacts to be added to another module Maximum achievable safety level PL e/category 4 conforming to EN/ISO 3849-, SILCL 3 conforming to EN/IEC 6206 (when connected to the appropriate module) Conformity to standards EN/IEC , EN 088/ISO 49, EN/ISO 3850, EN/IEC , EN/IEC Product certifications UL, CSA, BG UL, CSA, TÜV PL e/category 4 conforming to EN/ISO 3849-, SILCL 3 conforming to EN/IEC 6206 (when connected to the appropriate module) EN/IEC , EN/IEC , EN/IEC Number of circuits Safety 4 N.O. 8 N.O. Additional 2 N.C. outputs for signalling to PLC N.C. + solid-state output for signalling to PLC Display 2 LEDs 3 LEDs Supply voltage a and 24 V c a and 24 V c 5 V a 230 V a Module type XPSECME XPSECP Pages
8 Electrical ratings Preventa safety relay modules Electrical life Electrical life curves of safety contacts conforming to EN , table C2 XPSAC, XPSTSA, XPSTSW, XPSBA, XPSCM, XPSOT, XPSPVK, XPSPVT, XPSVNE XPSAXE, XPSECME 0 Switching current (A) Switching current (A) Number of operating cycles 0, XPSEDA XPSECP Number of operating cycles Switching current (A) Switching current (A) Number of operating cycles Number of operating cycles XPSATE 24 V z version 5 V a V a version DC DC 00 Switching current (A) XPSAF, XPSAK, XPSAFL Number of operating cycles Switching current (A) DC 0 AC Number of operating cycles XPSAV, XPSMP, XPSVC, XPSBF, XPSMC DC Switching current (A) Switching current (A) Number of operating cycles XPSABV Contacts 3-4, Contacts Number of operating cycles Switching current (A) Switching current (A) 0, 0, Number of operating cycles Number of operating cycles 6
9 Electrical ratings (continued) Preventa safety relay modules Electrical life (continued) Electrical life curves of safety contacts conforming to EN , table C2 XPSBCE 0 XPSAR Switching current (A) Switching current (A) DC DC 0, XPSDMB, XPSDME Switching current (A) DC Number of operating cycles Number of operating cycles Electrical life The product life expressed is based on average usage and normal operating conditions. The above statements are not intended to nor shall they create any express or implied warranties as to product operation or life. For information on the limited warranty offered on this product please refer to the Square D terms and conditions of sale found in Square D s Digest. Number of operating cycles Definition of tests Determination of electrical life conforming to EN (table C2) Type of current Utilization category Start-up Breaking Current Voltage Cos j Current Voltage Cos ϕ a.c. supply AC-5 0 x le Ue 0.7 le Ue 0.4 Type of current Utilization category Start-up Breaking Current Voltage T0.95 Current Voltage T0.95 d.c. supply DC-3 le Ue 50 ms le Ue 50 ms le: operational current measured. Ue: operational voltage measured. Cos j: power factor. T0.95: time taken to reach 95% of nominal current. Notes The tests are carried out with a frequency of 6 switching operations per minute and with no additional protection of the components connected to the safety outputs. The use of additional protection for the components connected to the safety outputs significantly increases the durability of the safety outputs. Determination of the breaking capacity conforming to EN (table 4) Utilization category Start-up Breaking Total number Current Voltage Cos j Current Voltage Cos j of switching operations Switching operations per minute for to 000 switching operations Switching operations per minute for 00 to 6050 switching operations Minimum duration of switching operation AC-5 0 x le Ue 0.3 le Ue ms Utilization category Start-up Breaking Total number Current Voltage T0.95 Current Voltage T0.95 of switching operations Switching operations per minute for to 000 switching operations Switching operations per minute for 00 to 6050 switching operations Minimum duration of switching operation DC-3 le Ue 50 ms le Ue 50 ms ms le: operational current measured. Ue: operational voltage measured. Cos j: power factor. T0.95: time taken to reach 95% of nominal current. Notes The maximum values for the breaking capacity of the safety outputs in the various utilization categories are not fixed and depend on the power factor and on the switching frequency. The test definition for the breaking capacity and durability tables in the European standard EN uses different values for the power factor and the switching frequency. The power factor (cos j) in the breaking capacity table (0.3) is greater than that in the durability table (0.7). In the breaking capacity table, the switching frequency of the safety outputs is higher for the first 000 switching operations (60 per minute) than that for 00 to 6050 switching operations (6 per minute). Consequently, the maximum breaking capacity values determined using the breaking capacity table are lower than those in the durability table. 7
10 Operating principle, specifications Preventa safety relay modules types XPSAC, XPSAXE For Emergency stop and switch monitoring Operating principle Safety relay modules XPSAC and XPSAXE are used for monitoring Emergency stop circuits conforming to standards EN/ISO 3850 and EN/IEC and also meet the requirements for the electrical monitoring of switches in protection devices conforming to standard EN 088/ISO 49. They provide protection for both the machine operator and the machine by immediately stopping the dangerous movement on receipt of a stop instruction from the operator, or on detection of an anomaly in the safety circuit itself. To aid diagnostics, the modules have LEDs which provide information on the monitoring circuit status. Specifications The XPSAC module has 3 safety outputs and a solid-state output for signalling to the PLC. The XPSAXE module has 3 safety outputs and a relay output for signalling to the PLC. Module type XPSAC, XPSACppppP XPSAXEppppP, XPSAXEppppC Maximum achievable safety level Reliability data () PL e/category 4 conforming to EN/ISO 3849-, SILCL 3 conforming to EN/IEC 6206 Mean Time To dangerous Failure Years (MTTF d) Diagnostic Coverage (DC) % > 99 > 99 Probability of dangerous Failure per Hour (PFH d) /h 3.56 x x 0-8 Conformity to standards EN/IEC , EN 088/ISO 49, EN/ISO 3850, EN/IEC , EN/IEC PL e/category 4 conforming to EN/ISO SILCL 3 conforming to EN/IEC 6206 EN/IEC , EN 088/ISO 49, EN/ISO 3850, EN/IEC , EN/IEC Product certifications UL, CSA, TÜV UL, CSA, BG Supply Voltage V a and 24 c, 48 a, 5 a, 230 a a and 24 c Voltage limits - 20 to + 0% (24 V a) - 5 to + 0% - 20 to + 20% (24 V c) - 5 to + 0% (48 V a) - 5 to + 5 % (5 V) - 5 to + 0% (230 V) Frequency Hz 50/60 50/60 Power consumption W <.2 (24 V c) VA < 2.5 (24 V a) <.6 (for 24VDC) / < 2.2 (for 24VAC) < 6 (48 V a) < 7 (5 V a) < 6 (230 V a) Start button monitoring No No Control unit voltage Identical to supply voltage (at nominal supply voltage) 24 V version V 24 a (approx. 90 ma), 24 c (approx. 40 ma) 24 c 48 V version V 48 a (approx. 00 ma) 5 V version V 5 a (approx. 60 ma) 230 V version V 230 a (approx. 25 ma) Outputs Voltage reference Relay hard contacts Relay hard contacts Number and type of safety circuits 3 N.O. (3-4, 23-24, 33-34) 3 N.O. (3-4, 23-24, 33-34) Number and type of additional solid-state N.C. relay (4-42) circuits Breaking capacity in AC-5 VA C300: inrush 800, maintained 80 B300 Breaking capacity in DC-3 24 V/2 A L/R = 50 ms 24 V/.5 A L/R = 50 ms Max. thermal current (Ithe) A 6 8/5 (N.O. / N.C.) Max. total thermal current A Output fuse protection, using fuses A 4 gg (gl) or 6 fast acting 6gG conforming to IEC/EN , DIN VDE 0660 part 200 Minimum current ma 0 0 Minimum voltage V 7 7 Electrical life See page 6 Response time on input opening ms < 00 < 80 Rated insulation voltage (Ui) V 300 (degree of pollution 2 conforming to IEC/EN , DIN VDE 00 parts & 2) Rated impulse withstand voltage (Uimp) kv 3 (overvoltage category III, conforming to IEC/EN , DIN VDE 00 parts & 2) 4 (overvoltage category III, conforming to IEC/EN , DIN VDE 00 parts & 2) LED display 2 2 Operating temperature F ( C) + 4 to + 3 (- 0 to + 55) - 3 to +3 (- 25 to + 55) Storage temperature F ( C) - 3 to +85 (- 25 to + 85) - 3 to +67 (- 25 to + 75) Degree of protection Terminals IP 20 IP 20 conforming to IEC/EN Enclosure IP 40 IP 40 () Per EN/ISO and EN/IEC 6206 page 9 Wiring diagrams: page 0 8
11 Specifications (continued), references Preventa safety relay modules types XPSAC, XPSAXE For Emergency stop and switch monitoring Specifications (continued) Module type XPSAC XPSACppppP XPSAXEppppP XPSAXEppppC Connection Type Terminals Captive screw clamp terminals Captive screw clamp terminals Integrated in module Removable from module -wire connection Without cable end Solid or flexible cable: 26-4 AWG (0.4 to 2.5 mm 2 ) Captive screw clamp terminals Removable from module Solid or flexible cable: 24-4 AWG (0.2 to 2.5 mm 2 ) With cable end Without bezel, flexible cable: 24-4 AWG (0.25 to 2.5 mm 2 ) Spring terminals Removable from module References XPSACpppp With bezel, flexible cable: 24-6 AWG (0.25 to.5 mm 2 ) 2-wire connection Without cable end Solid or flexible cable: AWG (0.4 to 0.75 mm 2 ) With bezel, flexible cable: 0.25 to 2.5 mm 2 ) Solid cable: 24-8 AWG (0.2 to mm 2 ), flexible cable: 24-6 AWG (0.2 to.5 mm 2 ) With bezel, flexible cable: 24-6 AWG (0.25 to.5 mm 2 ) Solid or flexible cable: 24-8 AWG (0.2 to mm 2 ) With bezel, flexible cable: 24-4 AWG (0.25 to 2.5 mm 2 ) With cable end Without bezel, flexible cable: 24-8 AWG ( mm 2 ) Double, with bezel, flexible cable: 20-6 AWG (0.5 to.5 mm 2 ) Double, with bezel, flexible cable: 0-8 AWG (0.5 to mm 2 ) Description Connection Number of Additional instantaneous outputs opening safety circuits Safety modules for Emergency stop and switch monitoring Captive screw clamp terminals integrated in module Supply Reference Weight oz (kg) 3 solid-state a and 24 V c XPSAC (0.60) 48 V a XPSAC (0.20) 5 V a XPSAC (0.20) 230 V a XPSAC (0.20) XPSACppppP Captive screw clamp terminals removable from module 3 solid-state a and 24 V c XPSAC52P (0.60) 48 V a XPSAC32P (0.20) 5 V a XPSAC342P (0.20) XPSAXE520P 230 V a XPSAC372P (0.20) relay a and 24 V c XPSAXE520P (0.229) XPSAXE520C Spring terminals removable from module 3 relay a and 24 V c XPSAXE520C (0.229) page 8 Wiring diagrams: page 0 9
12 Wiring diagrams Preventa safety relay modules type XPSAC For Emergency stop and switch monitoring XPSAC Module XPSAC associated with an Emergency stop button with N.C. contact Start Logic To PLC S: Emergency stop S2: Start button Y-Y2: Feedback loop. ESC: External start conditions. Module XPSAC associated with an Emergency stop button with 2 N.C. contacts (recommended application) F S S2 K3 Start K4 ESC de sécurité A Y Y XPSAC Y43 TA ence T Logic K K2 K3 K4 K3 K4 K3 K4 48 V, 5 V 230 V K K2 A2 PE K3 K4 Y44 To PLC S: Emergency stop S2: Start button Y-Y2: Feedback loop. ESC: External start conditions. Functional diagram of module XPSAC Emergency stop "A" (0) Supply voltage Start button not activated Start button activated Emergency stop not activated Emergency stop activated Emergency stop "A2" (02) Feedback loop Y-Y2 Output 3-4 (N.O.) Output (N.O.) Output (N.O.) Solid-state output Y43-Y44 (N.O.) Key 0 LED details 2 Supply voltage A-A2. 2 K-K2 status (N.O. safety outputs closed). page 8 n d'alimentation A-A2 0 K-K2 Specifications: page 8 page 9
13 Wiring diagrams (continued) Preventa safety relay modules type XPSAXE For Emergency stop and switch monitoring XPSAXE Module XPSAXE associated with an Emergency stop button with N.C. contact Start Logic S: Emergency stop S2: Start Y-Y2: Feedback loop ESC: External start conditions () Automatic reset (2) Maximum fuse rating: see page 8. Module XPSAXE associated with an Emergency stop button with 2 N.C. contacts (recommended application) Start ns de sécurité NTA rgence Logic S: Emergency stop S2: Start Y-Y2: Feedback loop ESC: External start conditions () Automatic reset (2) Maximum fuse rating: see page 8. Functional diagram of module XPSAXE Supply voltage Emergency stop "A" (0) Start button not activated Start button activated Emergency stop not activated Emergency stop activated Emergency stop "A2" (02) () Feedback loop Y-Y2/Y3 Output 3-4 (N.O.) Output (N.O.) Output (N.O.) Solid-state output 4-42 (N.C.) Key 0 () Only for Emergency stop button with 2 N.C. contacts. LED details 2 Supply voltage A-A2. 2 K-K2 status (N.O. safety outputs closed). page 8 ion d'alimentation A-A2 de K-K2 Specifications: page 8 page 9
14 Operating principle, specifications Preventa safety relay modules types XPSAV, XPSABV, XPSATE For Emergency stop and switch monitoring Operating principle Safety relay modules XPSAV, XPSABV and XPSATE are used for monitoring Emergency stop circuits conforming to standards EN/ISO 3850 and EN/IEC and also meet the requirements for the electrical monitoring of switches in protection devices conforming to standard EN 088 / ISO 49. They provide protection for both the machine operator and the machine by immediately stopping the dangerous movement on receipt of a stop instruction from the operator, or on detection of an anomaly in the safety circuit itself. Specifications Module type In addition to the stop category 0 instantaneous opening safety outputs (3 for XPSAV, 2 for XPSABV and 2 for XPSATE), the modules incorporate stop category time delay outputs (3 for XPSAV, for XPSABV and 3 for XPSATE) which allow for controlled deceleration of the motor components until a complete stop is achieved (for example, motor braking by variable speed drive). At the end of the preset delay, the supply is disconnected by opening the time delay output circuits. For module XPSAV, the time delay of the 3 output circuits is adjustable, in 5 preset values, between 0 and 300 seconds using selector buttons. For module XPSABV, the time delay of the output circuit is adjustable between 0.5 and 3 seconds or.5 and 30 seconds, depending on the model, using a selector switch. For module XPSATE, the time delay of the 3 output circuits is adjustable between 0 and 30 seconds using a 2-position selector switch. Module XPSAV also incorporates 3 solid-state signalling outputs for signalling to the process PLC. Module XPSATE incorporates 4 solid-state signalling outputs for signalling to the process PLC. To aid diagnostics, the modules have LEDs which provide information on the monitoring circuit status. The Start button monitoring function is configurable depending on the wiring. XPSAV3, XPSAV3P Maximum achievable safety level PL e/category 4 conforming to EN/ISO SILCL 3 (instantaneous safety outputs and time delay safety outputs) conforming to EN/IEC 6206 Reliability data () (instantaneous safety outputs) Reliability data () (time delay safety outputs) XPSABVppppC, XPSABVppppP PL e/category 4 (instantaneous safety outputs) and PL d/category 3 (time delay safety outputs) conforming to EN/ISO 3849-, SILCL 3 (instantaneous safety outputs) and SILCL 2 (time delay safety outputs) conforming to EN/IEC 6206 XPSATEpppp, XPSATEppppP Mean Time To dangerous Failure Years (MTTF d) Diagnostic coverage (DC) % > 99 > 99 > 99 Probability of dangerous Failure per Hour (PFH d) /h 7.95 x x x 0-9 Mean Time To dangerous Failure Years (MTTF d) Diagnostic coverage (DC) % > 99 > 60 and < Probability of dangerous Failure /h 7.95 x x x 0-8 per Hour (PFH d) Conformity to standards EN/IEC , EN/IEC , EN/IEC , EN/ISO 3850, EN 088/ISO 49, EN/IEC , EN/IEC , EN/IEC , EN/ISO 3850, EN 088/ISO 49 PL e/category 4 (instantaneous safety outputs) and PL d/category 3 (time delay safety outputs) conforming to EN/ISO 3849-, SILCL 3 (instantaneous safety outputs) and SILCL 2 (time delay safety outputs) conforming to EN/IEC 6206 EN/IEC , EN/IEC , EN/IEC , EN/ISO 3850, EN 088/ISO 49 Product certifications UL, CSA, TÜV UL, CSA, BG UL, CSA, TÜV Supply Voltage V 24 c 24 c a and 24 c, 5 a, 230 a Voltage limits - 20 to + 20% - 5 to + 0% - 20 to + 0% (24 V) - 5 to + 5% (5 V) - 5 to + 0% (230 V) Frequency Hz 50/60 Power consumption W < 5 < 3 < 8 Module inputs fuse protection Internal, electronic Adjustable time delay s 0 to to 3 or.5 to 30 0 to 30 Start button monitoring Yes/No (configurable by terminal wiring diagrams) Control unit voltage (at nominal supply voltage) Between input terminals S2-S22, S3-S32 or S-S2 Between input terminals S-S2, S2-S22 or S-S3 24 V version V V, 230 V version V 48 () Per EN/ISO and EN/IEC 6206 Between input terminals S-S2, S2-S22 or S-B page 4 2 Wiring diagrams: page 5
15 Specifications (continued) Preventa safety relay modules types XPSAV, XPSABV, XPSATE For Emergency stop and switch monitoring Specifications (continued) Module type XPS... AV3 AV3P ABVppppP ABVppppC ATEpppp ATEppppP Calculation of wiring resistance RL between input terminals W 00 max. Maximum cable length: 2000 m Synchronization time between inputs s For guard:.5 For Emergency stop: unlimited RL = Ue Un x Ue = true voltage applied to terminals A-A2 Un = nominal supply voltage RL max. = U int - U min. I min. Ue = true voltage applied to terminals A-A2 U int (terminals S-S2) = supply voltage Ue - 3 V (24 V version) U int between 42 V and 45 V, with typical value = 45 V (5 V, 230 V version) Calculated max. RL must be equal to or greater than the true value < 0.5 Approx For automatic start, terminals S33-Y2 and Y3-Y4 linked Outputs Voltage reference Relay hard contacts No. and type of instantaneous opening safety circuits 3 N.O. (03-04, 3-4, 23-24) 2 N.O. (3-4, 23-24) 2 N.O. (3-4, 23-24, 33-34) No. and type of time delay opening safety circuits 3 N.O. (37-38, 47-48, 57-58) N.O. (37-38) 3 N.O. (57-58, 67-68, 77-78) Number and type of additional circuits 3 solid-state 4 solid-state Breaking capacity in AC-5 Instantaneous outputs VA C300: inrush 800, maintained 80 B300: inrush 3600, maintained 360 C300: inrush 800, maintained 80 Time delay outputs VA C300: inrush 800, maintained 80 B300: inrush 3600, maintained 360 C300: inrush 800, maintained 80 Breaking capacity Instantaneous 24 V/.25 A L/R = 50 ms 24 V/.5 A L/R = 50 ms 24 V/.0 A L/R = 50 ms in DC-3 outputs Time delay outputs 24 V/.25 A L/R = 50 ms 24 V/.5 A L/R = 50 ms 24 V/.0 A L/R = 50 ms Breaking capacity of solid-state outputs 24 V/20 ma Max. thermal current Instantaneous A 3.3 for all 3, or 6 for and (Ithe) outputs for 2, or 4 for 2 and 2 for Time delay outputs A 3.3 for all 3, or 6 for and for 2, or 4 for 2 and 2 for Max. total thermal current A Output fuse protection, Instantaneous A 4 gg or 6 fast acting 6 gg 6 gg using fuses conforming to IEC/EN , outputs Time delay outputs A 4 gg or 6 fast acting 6 gg 4 gg DIN VDE 0660 part 200 Minimum current ma 0 () 0 0 () Minimum voltage V 7 () 7 7 () Electrical life See page 6 Response time on instantaneous opening inputs ms < 30 < 200 < 20 Rated insulation voltage (Ui) V 300 (degree of pollution 2 conforming to IEC/EN , DIN VDE 00 parts & 2) Rated impulse withstand voltage (Uimp) kv 4 (overvoltage category III, conforming to IEC/EN , DIN VDE 00 parts & 2) LED display 3 4 Operating temperature F ( C) + 4 to + 3 (- 0 to + 55) - 3 to +3 (- 25 to + 55) + 4 to + 3 (- 0 to + 55) Storage temperature F ( C) - 3 to +85 (- 25 to + 85) - 3 to +67 (- 25 to + 75) - 3 to +85 (- 25 to + 85) Degree of protection Terminals IP 20 conforming to IEC/EN Enclosure IP 40 Wiring diagrams Type of terminals Captive screw clamp terminals Spring terminals Captive screw clamp terminals Type of terminal block Integrated Removable from module in module -wire connection Without cable end Solid or flexible cable: 26-4 Solid or flexible cable: 24-4 AWG (0.2 to 2.5 mm 2 ) Solid or flexible cable: 26-4 Solid or flexible cable: 24-4 AWG (0.4 to AWG (0.4 to 2.5 AWG (0.25 to mm 2 ) mm 2 ) mm 2 ) With cable end Without bezel, flexible cable: 24-4 AWG (0.25 to 2.5 mm 2 ) With bezel, flexible cable: With bezel, flexible cable: With bezel, flexible cable: With bezel, flexible cable: With bezel, flexible cable: With bezel, flexible cable: 24-6 AWG ( AWG ( AWG ( AWG ( AWG ( AWG (0.25 to.5 mm 2 ) to 2.5 mm 2 ) to.5 mm 2 ) to 2.5 mm 2 ) to.5 mm 2 ) to 2.5 mm 2 ) 2-wire connection Without cable end Solid or flexible Solid cable: Solid or flexible Solid or flexible Solid cable: cable: AWG (0.2 cable: 24-8 cable: AWG AWG (0.4 to 0.75 mm 2 ) to mm 2 ) Flexible cable: 24-6 AWG (0.2 to.5 mm 2 ) AWG (0.2 to mm 2 ) AWG (0.4 to 0.75 mm 2 ) (0.2 to mm 2 ) Flexible cable: 24-6 AWG (0.2 to.5 mm 2 ) With cable end Without bezel, flexible cable: 24-8 AWG (0.25 to mm 2 ) Without bezel, flexible cable: 24-8 AWG (0.25 to mm 2 ) Double, with bezel, flexible cable: 20-6 AWG (0.5 to.5 mm 2 ) Double, with bezel, flexible cable: 20-8 AWG (0.5 to mm 2 ) Double, with bezel, flexible cable: 20-6 AWG (0.5 to.5 mm 2 ) () The module is also capable of switching low power loads (7 V/0 ma) provided that the contact has not been used for switching high power loads (possible contamination or wear of the gold layer on the contact tips). page 2 page 4 Wiring diagrams: page 5 3
16 References Preventa safety relay modules types XPSAV, XPSABV, XPSATE For Emergency stop and switch monitoring References Description Safety modules for Emergency stop and switch monitoring Number of safety circuits 6 N.O. (3 N.O. time delay) Additional outputs Setting range of time delay Supply Connection Reference Weight 3 solid-state 0 to 300 s 24 V c Captive screw clamp terminals integrated in module oz (kg) XPSAV3.288 (0.320) XPSAV3 6 N.O. (3 N.O. time delay) 3 N.O. ( N.O. time delay) 3 solid-state 0 to 300 s 24 V c Captive screw clamp terminals removable from module 0.5 to 3 s 24 V c Captive screw clamp terminals removable from module 24 V c Spring terminals removable from module XPSAV3P.288 (0.320) XPSABV33P (0.280) XPSABV33C (0.275) XPSAV3P.5 to 30 s 24 V c Captive screw clamp terminals removable from module XPSABV330P (0.280) 24 V c Spring terminals removable from module XPSABV330C (0.275) XPSABVppppP 5 N.O. (3 N.O. time delay) 4 solid-state 0 to 30 s a/24 V c Captive screw clamp terminals integrated in module Captive screw clamp terminals removable from module 5 V a Captive screw clamp terminals integrated in module XPSATE (0.280) XPSATE50P (0.280) XPSATE (0.380) XPSABVppppC Captive screw clamp terminals removable from module XPSATE340P (0.380) 230 V a Captive screw clamp terminals integrated in module XPSATE (0.380) XPSATE50 Captive screw clamp terminals removable from module XPSATE370P (0.380) page 2 Specifications: page 2 Wiring diagrams: page 5 4
17 Wiring diagrams Preventa safety relay modules type XPSAV For Emergency stop and switch monitoring XPSAV Module XPSAV associated with an Emergency stop button with N.C. contact, automatic start or unmonitored start Emergency stop To PLC Start Logic channel Output Output 2 Logic channel 2 Output Output 2 Fault Time delay stop () Link for automatic start. (2) Instantaneous opening safety outputs (stop category 0). (3) Time delay opening safety outputs (stop category ). ESC = External start conditions. Functional diagrams Automatic start Emergency stop S-S2 Automatic start (without ESC) S3-S4 Linked input S2-S22 Linked input S3-S32 Time delay interrupt Y39-Y40 N.O. output 03-04/3-4/23-24 N.O. output 37-38/47-48/57-58 Signalling output Y74 Signalling output Y84 Power-up Emergency stop not activated Emergency stop activated Emergency stop not activated Emergency stop activated Start Tv = 0 to 300 s Start Time delay interrupted Unmonitored start Power-up Emergency stop not activated Emergency stop S-S2 Start button S3-S4 Linked input S2-S22 Linked input S3-S32 Time delay interrupt Y39-Y40 N.O. output 03-04/3-4/23-24 N.O. output 37-38/47-48/57-58 Signalling output Y74 Signalling output Y84 Start Emergency stop activated Emergency stop not activated Emergency stop activated Tv = 0 to 300 s Start Time delay interrupted Automatic start There is no start contact or it is jumpered (wiring between terminals S3 - S4). Note: Automatic start function is not available on the XPSAV with 2 channel wiring on the inputs. Automatic start function is only available on single channel wiring on the inputs. Unmonitored start The output is activated on closing of the start contact. Monitored start The start input is monitored so that there is no start-up in the event of the start contact being jumpered or the start circuit being closed for more than 0 seconds. Start-up is triggered following activation of the start button (push-release function) on opening of the contact (wiring between terminals S33-S34). page 2 Specifications: page 2 page 4 5
18 Wiring diagrams (continued) Preventa safety relay modules type XPSAV For Emergency stop and switch monitoring XPSAV Module XPSAV associated with an Emergency stop button with 2 N.C. contacts, monitored start* To PLC Emergency stop Logic channel Output Output 2 Logic channel 2 Output Output 2 Fault Emergency stop Time delay stop Start () Instantaneous opening safety outputs (stop category 0). (2) Time delay opening safety outputs (stop category ). ESC = External start conditions. *Automatic start function is not available on the XPSAV with 2 channel wiring on the inputs. Automatic start function is only available on single channel wiring on the inputs. Functional diagram Monitored start Power-up Linked input S-S2 Emergency stop (channel ) S2-S22 Emergency stop (channel 2) S3-S32 Start button S33-S34 Time delay interrupt Y39-Y40 N.O. output 03-04/3-4/23-24 N.O. output 37-38/47-48/57-58 Signalling output Y74 Signalling output Y84 Emergency stop not activated No start-up Emergency stop activated Emergency stop not activated Emergency stop activated Start Tv = 0 to 300 s Start Time delay interrupted Emergency stop monitoring function configuration -channel wiring S 2-channel wiring, with short-circuit detection S A S S2 S3 S32 XPSAV A S S2 S3 S32 XPSAV A2 S2 S22 A2 S2 S22 page 2 Specifications: page 2 page 4 6
19 Wiring diagrams (continued) Preventa safety relay modules type XPSAV For Emergency stop and switch monitoring XPSAV Monitoring of a movable guard associated with 2 switches Automatic start (diagram shown for guard closed) Guard closed To PLC Logic channel Output Output 2 Logic channel 2 Output Output 2 Fault Guard closed Time delay stop () Instantaneous opening safety outputs (stop category 0). (2) Time delay opening safety outputs (stop category ). ESC = External start conditions. Functional diagram Linked input S-S2 Guard (channel ) S2-S22 Guard (channel 2) S3-S32 Guard open S3-S4 Time delay interrupt Y39-Y40 N.O. output 03-04/3-4/23-24 N.O. output 37-38/47-48/57-58 Signalling output Y74 Signalling output Y84 LED details Power-up Guard closed Guard open Start Guard closed Guard open Tv = 0 to 300 s Start Guard closed Guard open Time delay interrupted S2 input status. 2 S22 input status. 3 S32 input status. 4 S34 input status. 5 S4 input status. 6 Y40 input status (time delay stop). 7 K/K2 status (N.O. instantaneous opening safety outputs). 8 K3/K4 status (time delay opening safety outputs). 9 Supply voltage A-A2. 0 Fault. Configuration mode. page 2 Specifications: page 2 page 4 7
20 Wiring diagrams Preventa safety relay modules type XPSABV For Emergency stop and switch monitoring XPSABV Module XPSAV associated with an Emergency stop button with 2 N.C. contacts, monitored start + 24 V F0 Feedback loop () (2) S2 F (3) F2 (3) F3 (3) A S33 S34 S XPSABV Reset K Control logic K2 Supply Time (s) channel channel 2 channel 2 K3 K4 0 V A2 S2 S S2 S22 S Stop category 0 Stop category 0 Safety outputs Stop category S: Emergency stop S2: Start button ESC = External start conditions. () With start button monitoring. (2) Without start button monitoring or automatic start. (3) Maximum fuse rating: see page 2. Emergency stop or switch monitoring function configurations S S2 S3 S33 S34 S2 S22 XPSABV ON -channel Emergency stop, manual start 2 Start with S34 button monitoring Jumper ON S S2 S3 S33 S34 S2 S22 XPSABV Short-circuit monitoring 2-channel Emergency stop, manual start Start with S34 button monitoring Jumper 3 ON S S2 S2 S22 S33 S34 S S3 XPSABV Short-circuit monitoring 2-channel Emergency stop, manual start 4 Start with S34 button monitoring Jumper S S2 S2 S22 S33 S35 S S3 XPSABV Machine guard with short-circuit monitoring, automatic start Jumper or feedback loop for external contactors (automatic start S35) Jumper page 2 Specifications: page 2 page 4 8
21 Wiring diagrams (continued) Preventa safety relay modules type XPSABV For Emergency stop and switch monitoring XPSABV Functional diagrams Emergency stop monitoring: configurations, 2 and 3 Supply voltage (A-A2) Power-up Begin Emergency stop not activated Emergency stop activated Begin. Channel (S-S2) 2. Channel S2-S22 (S-S3) Falling edge start S33-S34 Rising edge start S33-S35 Output 3-4, (N.O.) Output (N.O.) 0 tw >tm te ta tv >tm te >ta tw: Recovery time te: On-delay tm: Min. ON time ta: Response time tv: Off-delay (adjustable) ts: Synchronization time Switch monitoring: configuration 4 Power-up Guard closed Guard open Guard closed Supply voltage (A-A2). Channel (S-S2) 2. Channel S2-S22 (S-S3) Rising edge start S33-S35 Output 3-4, (N.O.) Output (N.O.) 0 te2 ta tv tw ts te2 ta tw: Recovery time te: On-delay tm: Min. ON time ta: Response time tv: Off-delay (adjustable) ts: Synchronization time LED details 2 3 Supply voltage A-A2 2 K/K2 status 3 K3/K4 status page 2 Specifications: page 2 page 4 9
22 Wiring diagrams Preventa safety relay modules type XPSATE For Emergency stop and switch monitoring XPSATE Module XPSATE associated with an Emergency stop button* Logic Start Stop category 0 Instantaneous opening safety outputs Stop category Time delay opening safety outputs To PLC S: Emergency stop button with 2 N.C. contacts (recommended application). S2: Start button. ESC: External start conditions. Y (S33) - Y2: Feedback loop. F: 4 A max. () With start button monitoring. (2) Without start button monitoring. (3) The outputs must be fuse protected. Technical specifications for maximum rating of fuses, see page 2. (4) a 5/230 V only. *For automatic start, jumper S2 (N.O. start button between terminals S33-Y). This is only feasible when configured without start button monitoring (Y3 and Y4 jumpered). If S2 is jumpered and the module is configured for start button monitoring (Y3 and Y5 jumpered), the N.O. safety contacts will not close. Functional diagram of module XPSATE with Emergency stop button monitoring Supply voltage Begin Emergency stop not activated Emergency stop activated With Start button Emergency stop (O) Solid-state output Y89 (S2) Emergency stop (O2) Solid-state output Y90 (S22) Start button Start button 2 Tmax. = 75 ms Without Start button Emergency stop (O2 or O) Solid-state output Y89 (S2) Emergency stop (O2 or O) Solid-state output Y90 (S22) Start button 3 Outputs Key 0 With start button monitoring (Y3-Y5 connection). 2 Without start button monitoring (Y3-Y4 connection) LED details External start conditions Output 3-4 (N.O.) Output (N.O.) Output (N.O.) Output (N.O.) Output (N.O.) Solid-state output Y88 (A/A2) Solid-state output Y9 (Stop ) Tv = 0 30 s 3 Without start button (connection Y3-Y4 and S33-Y). Tv: adjustable time. Supply voltage A-A2, internal electronic fuse status. 2 S2 (A) input status. 3 S22 (B) input status. 4 Stop category outputs closed. page 2 Specifications: page 2 page 4 20
23 Wiring diagrams (continued) Preventa safety relay modules type XPSATE For Emergency stop and switch monitoring XPSATE Example of a circuit combining an Emergency stop module with a variable speed drive PLC Start To PLC S: Emergency stop button with 2 N.C. contacts (recommended application). S2: Start button () With start button monitoring. (2) Technical specifications for establishing maximum rating of fuses, see page 2. Connection with Emergency stop button Connection with multiple Emergency stop buttons S S A S2 S B S2 S XPSATE Both input channels are supplied at the same potential. S: Emergency stop button with 2 N.C. contacts A short-circuit between the 2 inputs is not detected. S3 A S2 S B S2 S XPSATE S2 The 2 input channels are supplied at different potentials. A short-circuit between the 2 inputs is detected. Configuration with start button monitoring (functional diagram for Start button, see page 5) Monitoring an Emergency stop button with N.C. contact XPSATE A2 PE S33 Y Y2 Y3 Y4 Y5 S2 () () Auxiliary terminal (to be used to separate the feedback loop from the wiring to the start button). Configuration without start button monitoring (functional diagram for Start button 2, see page 5) A S2 S B S2 S XPSATE S S: Emergency stop button with N.C. contact. Not all faults are detected: a short-circuit on the Emergency stop pushbutton is not detected. XPSATE A2 PE S33 Y Y2 Y3 Y4 Y5 S2 () () Auxiliary terminal (to be used to separate the feedback loop from the wiring to the start button). page 2 Specifications: page 2 page 4 2
24 Operating principle Preventa safety relay modules types XPSBA, XPSBCE, XPSBF For electrical monitoring of two-hand control stations Operating principle Two-hand control stations are designed to provide protection against hand injury. They require machine operators to keep their hands clear of the hazardous movement zone. The use of two-hand control is an individual protective measure, which can protect only one operator. Separate two-hand control stations must be provided for each operator in a multiple-worker environment. Safety relay modules XPSBA, BCE and BF for two-hand control stations comply with the requirements of European standard EN 574/ISO 385 for two-hand control systems. The control stations must be designed and installed such that they cannot be activated involuntarily or easily rendered inoperative. Depending on the application, the requirements of type C standards specific to the machinery involved must be met (additional personal protection methods may have to be considered). To initiate a hazardous movement, both operators (two-hand control pushbuttons) must be activated within an interval y 0.5 s (synchronous activation). If one of the two pushbuttons is released during a hazardous operation, the control sequence is cancelled. Resumption of the hazardous operation is possible only if both pushbuttons are returned to their initial position and reactivated within the required time interval. The control sequence does not occur if: Both two-hand control push buttons are pressed during a time period greater than 0.5 seconds, A short-circuit is present in a push button contact, The feedback loop is not closed at start-up. The safety distance between the control units and the hazardous zone must be sufficient that when only one operator is released, the hazardous zone cannot be reached before the hazardous movement has been completed or stopped. XPSBA This module is designed for use on lighter duty applications where a two-hand control function is desired, but where the safety category is B or (per EN 954-) and the two-hand control requirements meet Type III A (per EN 574/ISO 385). This module is not to be used for applications, such as presses, which require a Type III C module or where the application is not a category B or. For press applications, for applications in category 2, 3, or 4, or if application calls for a Type III C module, use XPSBCE or XPSBF module. XPSBCE and XPSBF These modules can be used on applications, such as presses, which require a Type III C module. The XPSBCE and XPSBF can be used for a two-hand control application, including presses and similar equipment. Specifications: page 23 page 25 Wiring diagrams: page 26 22
25 Specifications Preventa safety relay modules types XPSBA, XPSBCE For electrical monitoring of two-hand control stations Specifications Module type XPSBA XPSBCEppppP XPSBCEppppC Maximum achievable safety level PL c/category conforming to EN/ISO PL e/category 4 conforming to EN/ISO 3849-, SILCL 3 conforming to EN/IEC 6206 Reliability data () Mean Time To dangerous Failure (MTTF d) Years Diagnostic Coverage (DC) % > 99 Probability of dangerous Failure per Hour (PFH d) /h 7. x x 0-8 Conformity to standards EN/IEC , EN/IEC , EN/IEC , EN 574 type III A/ISO 385 EN/IEC , EN/IEC , EN/IEC , EN 574 type III C/ISO 385 Product certifications UL, CSA, TÜV UL, CSA, BG Supply Voltage V 24 z, 5 a, 230 a 24 c, 24 a, 5 a, 230 a Voltage limits - 20 to + 20% (24 V c), - 20 to + 0% (24 V a) Frequency Hz 50/60 Power consumption VA < 20 (apparent power) < 4 Module inputs fuse protection Internal, electronic Inputs S: N.C. + N.O., S2: N.C. + N.O. Two-hand control type III A III C Conforming to EN 574 Synchronization time s 0.5 maximum Control unit voltage Minimum voltage and current 24 V c version V V a, 5 V, 230 V version V Between terminals T-T2, T-T3 U min./i min. to 24 V c version (20 C) 8 V/30 ma U min./i min. to 24 V a/5 V/230 V version (20 C) 8 V/30 ma Calculation of wiring resistance RL (for XPSBCE only) between terminals S-S3, S2-S23 W c - 5 to + 0% (24 V c, 24 V a), - 5 to + 5% (5 V a), - 5 to + 0% (230 V a) RL = Ue Un x a RL = Ue Un x Ue = true voltage applied to terminals A-A2 Un = nominal supply voltage Outputs Voltage reference Relay hard contacts Number and type of safety circuits N.O. (-4) 2 N.O. (3-4, 23-24) Number and type of additional circuits N.C. (-2) N.C. (3-32) Breaking capacity in AC-5 VA C300: inrush 800, maintained 80 B300: inrush 3600, maintained 360 Breaking capacity in DC-3 24 V/.5 A to L/R = 50 ms Max. thermal current (Ithe) A 5 6 Output fuse protection, using fuses conforming A 4 gg or 6 fast acting 6 gg to IEC/EN , VDE 0660 part 200 Minimum current ma 0 Minimum voltage V 7 Electrical life See page 6 Response time ms < 25 < 50 Rated insulation voltage (Ui) V 300 (degree of pollution 2 conforming to IEC/EN , DIN VDE 00 parts & 2) Rated impulse withstand voltage (Uimp) kv 4 (overvoltage category III, conforming to IEC/EN , DIN VDE 00 parts & 2) LED display 2 3 Operating temperature F ( C) + 4 to + 3 (- 0 to + 55) - 3 to + 3 (- 25 to + 55) Storage temperature F ( C) + 3 to + 85 (- 25 to + 85) - 3 to + 67 (- 25 to + 75) Degree of protection conforming to IEC/EN Terminals IP 20 Enclosure IP 40 Wiring diagrams Type Terminals Captive screw clamp terminals Captive screw clamp Spring terminals terminals Integrated in module Removable from module -wire connection Without cable end Solid or flexible cable: Solid or flexible cable: 24-4 AWG (0.2 to 2.5 mm 2 ) 26-4 AWG (0.4 to 2.5 mm 2 ) With cable end Without bezel, flexible cable: 24-4 AWG (0.25 to 2.5 mm 2 ) With cable end With bezel, flexible cable: 24-6 AWG (0.25 to.5 mm 2 ) With bezel, flexible cable: 24-4 AWG (0.25 to 2.5 mm 2 ) 2-wire connection Without cable end Solid or flexible cable: Solid or flexible cable: AWG (0.4 to 0.75 mm 2 ) 24-8 AWG (0.2 to mm 2 ) With cable end Without bezel, flexible cable: 24-8 AWG (0.25 to mm 2 ) () Per EN/ISO and EN/IEC 6206 With cable end Double, with bezel, flexible cable: 20-6 AWG (0.5 to.5 mm 2 ) Double, with bezel, flexible cable: 20-8 AWG (0.5 to mm 2 ) page 22 page 25 Wiring diagrams: page 26 23
26 Specifications (continued) Preventa safety relay modules type XPSBF For electrical monitoring of two-hand control stations Specifications Module type XPSBF32 XPSBF32P Maximum achievable safety level PL e/category 4 conforming to EN/ISO 3849-, SILCL 3 conforming to EN/IEC 6206 Reliability data () Mean Time To dangerous Failure (MTTF d) Years 50. Diagnostic Coverage (DC) % > 99 Probability of dangerous Failure per Hour /h.3 x 0-8 (PFH d) Conformity to standards EN , EN , EN , EN 574 type III C/ISO 385 Product certifications UL, CSA, TÜV Supply Voltage V 24 c Voltage limits - 20 to + 20% Power consumption W < 2.5 Module inputs fuse protection Internal, electronic Inputs S: N.C. + N.O., S2: N.C. + N.O. Two-hand control type III C conforming to EN 574 Synchronization time s 0.5 maximum Control unit voltage V 24 V/8 ma Outputs Voltage reference Relay hard contacts Number and type of safety circuits 2 N.O. (3-4, 23-24) Number and type of additional circuits 2 solid-state (type 24 V to 20 ma) Breaking capacity in AC-5 VA C300: inrush 800, maintained 80 Breaking capacity in DC-3 24 V/.5 A to L/R = 50 ms Max. thermal current (Ithe) A 4.2 Max. total thermal current A 8.4 Output fuse protection, using fuses A 4 gg or 6 fast acting conforming to IEC/EN , VDE 0660 part 200 Minimum current ma 0 Minimum voltage V 7 Electrical life See page 6 Response time ms < 20 Rated insulation voltage (Ui) V 300 (degree of pollution 2 conforming to IEC/EN , DIN VDE 00 parts & 2) Rated impulse withstand voltage (Uimp) kv 4 (overvoltage category III, conforming to IEC/EN , DIN VDE 00 parts & 2) LED display 3 Operating temperature F ( C) + 4 to + 3 (- 0 to + 55) Storage temperature F ( C) -3 to +85 (- 25 to + 85) Degree of protection Terminals IP 20 conforming to IEC/EN Enclosure IP 40 Connection Type Terminals Captive screw clamp terminals Captive screw clamp terminals Integrated in module Removable from module -wire connection Without cable end Solid or flexible cable: 26-4 AWG (0.4 to 2.5 mm 2 ) Solid or flexible cable: 24-4 AWG (0.2 to 2.5 mm 2 ) With cable end Without bezel, flexible cable: 24-4 AWG (0.25 to 2.5 mm 2 ) With cable end With bezel, flexible cable: 24-6 AWG (0.25 to.5 mm 2 ) With bezel, flexible cable: 24-4 AWG (0.25 to 2.5 mm 2 ) 2-wire connection Without cable end Solid or flexible cable: AWG (0.4 to 0.75 mm 2 ) () Per EN/ISO and EN/IEC 6206 With cable end Without bezel, flexible cable: 24-8 AWG (0.25 to mm 2 ) With cable end Double, with bezel, flexible cable: 20-6 AWG (0.5 to.5 mm 2 ) Solid cable: 24-8 AWG (0.2 to mm 2 ), flexible cable: 24-6 AWG (0.2 to.5 mm 2 ) page 22 page 25 Wiring diagrams: page 26 24
27 Selection, references Preventa safety relay modules types XPSBA, XPSBCE, XPSBF For electrical monitoring of two-hand control stations Selection Standard EN 574/ISO 385 defines the selection of two-hand controls according to the control system category. The following table details the 3 types of two-hand control conforming to EN 574/ISO 385. For each type, it lists the operating specifications and minimum requirements. Requirements of standard EN 574/ ISO 385 Use of both hands (simultaneous action) Link between input and output signals Output signal inhibited Prevention of accidental operation Tamper-proof Output signal reinitialized Type I Type II Type III A B C Synchronous action (specified time limit) Use of proven components (Category conforming to EN/ISO 3849-) Redundancy with partial error detection (Category 3 conforming to EN/ISO 3849-) Redundancy + Self-monitoring (Category 4 conforming to EN/ISO 3849-) XPSBApp XPSBCE XPSBF XPSBCE XPSBF Meets the requirements of standard EN 574/ISO 385 References XPSBA520 Description Safety modules for electrical monitoring of two-hand control stations Type conforming to standard EN 574/ ISO 385 III A III C Connection Captive screw clamp terminals integrated in module Captive screw clamp terminals removable from module Conforming to standard EN/ISO Number of Additional safety circuits outputs Supply Reference Weight oz (kg) N.O. N.C. a or 24 V c XPSBA (0.200) 2 N.O. N.C. relay a and 24 V c XPSBCE30P (0.272) 5 V a XPSBCE340P.358 (0.322) 230 V a XPSBCE370P.358 (0.322) Spring terminals removable from module 2 N.O. N.C. relay a and 24 V c XPSBCE30C (0.272) 5 V a XPSBCE340C.358 (0.322) XPSBCEppppP XPSBCEppppC 230 V a XPSBCE370C.358 (0.322) Captive screw clamp terminals removable from module 2 N.O. 2 solid-state 24 V c XPSBF (0.50) 2 N.O. 2 solid-state 24 V c XPSBF32P 5.29 (0.50) XPSBF32 page 22 Specifications: page 23 Wiring diagrams: page 26 25
28 Wiring diagrams Preventa safety relay modules type XPSBA For electrical monitoring of two-hand control stations XPSBA Module XPSBA associated with a two-hand control station Type III A conforming to EN 574/ISO 385 L (+) F S S2 A T T T2 T3 + T Logic K XPSBA A2 2 4 N ( ) Signalling output Safety output S and S2: pushbuttons. Must not be used for applications (presses) which require a type III C module (XPSBCE or XPSBF). Functional diagram of module XPSBA Supply voltage Two-hand control not activated Button Button 2 Two-hand control activated Two-hand control not activated Supply A-A2 Input T-T2 (N.C.) Input T-T3 (N.O.) Safety output -4 (N.O.) Signalling output -2 (N.C.) Key 0 max. 500 ms max. 25 ms Response time LED details (XPSBA) 2 Supply voltage A-A2. 2 K status (N.O. safety output -4 closed). page 22 Specifications: page 23 page 25 26
29 Wiring diagrams Preventa safety relay modules type XPSBCE For electrical monitoring of two-hand control stations XPSBCE Module XPSBCE associated with a two-hand control station Type III C conforming to EN 574/ISO 385 a and 24 V c Logic 5 a and 230 V PE L (+) F S, S2: Two-hand control station pushbuttons ESC: External start conditions () Maximum fuse rating: see page 23. S S2 K3 K4 ESC () () A t S3 S2 S22 S23 Y Y K 24 V K2 K T Logic K2 XPSBCE K K2 A2 S S N (-) K3 K4 S, S2: Two-hand control station pushbuttons ESC: External start conditions () Maximum fuse rating: see page 23. page 22 Specifications: page 23 page 25 27
30 Wiring diagrams (continued) Preventa safety relay modules type XPSBCE For electrical monitoring of two-hand control stations XPSBCE (continued) Functional diagram of module XPSBCE Two-hand control not activated Two-hand control activated Two-hand control deactivated Button Button 2 Mushroom head S (N.C.) Mushroom head S (N.O.) Mushroom head S2 (N.C.) Mushroom head S2 (N.O.) Feedback loop Y-Y2 Output 3-4 (N.O.) Output (N.O.) Output 3-32 (N.C.) Key ts 0 ts, Synchronization time: 500 ms max. tr, Response time: 50 ms. tr LED details (XPSBCE) 2 3 Supply voltage A-A2. 2 K status (N.O. safety outputs closed). 3 K2 status (N.O. safety outputs closed). page 22 Specifications: page 23 page 25 28
31 Wiring diagrams Preventa safety relay modules type XPSBF For electrical monitoring of two-hand control stations XPSBF Module XPSBF associated with a two-hand control station F S XY2 SB ESC K3 K4 A S S2 S3 Y Y Logic Fault K/K2 K K XPSBF K2 K2 A2 S2 S22 S23 Y34 Y S2 XY2 SB To PLC K3 K4 ESC: External start conditions. Y-Y2: feedback loop Functional diagram of module XPSBF Two-hand control not activated Button Two-hand control activated Button 2 Two-hand control deactivated Mushroom head S (N.C.) Mushroom head S (N.O.) Mushroom head S2 (N.C.) Mushroom head S2 (N.O.) Feedback loop Output 3-4 (N.O.) Output (N.O.) Solid-state output Y34 (fault) Solid-state output Y44 (K/K2) T = 0.5 s max. T2 = 0.02 s max. Activated Deactivated Key LED details (XPSBF) 2 3 Supply voltage A-A2 (fuse status). 2 Fault signalling. 3 K-K2 status (N.O. safety outputs closed). page 22 Specifications: page 23 page 25 29
32 Operating principle, specifications Preventa safety relay modules types XPSECME, XPSECP For increasing the number of safety contacts Operating principle Safety relay modules XPSECME and XPSECP, for increasing the number of safety contacts, are available as additions to Preventa XPS base modules (Emergency stop, limit switch, two-hand control, etc.). They are used to increase the number of safety output contacts of the base modules. Specifications Module type XPSECMEppppP XPSECMEppppC XPSECPpppp Maximum achievable safety level PL e/category 4 conforming to EN/ISO 3849-, SILCL 3 conforming to EN/IEC 6206 (when connected to the appropriate module) Reliability data () Mean Time To dangerous Failure (MTTF d) Years Diagnostic Coverage (DC) % 60 to 90 0 to 99 Probability of dangerous Failure per Hour (PFH d) /h 2 x x 0-9 Conformity to standards EN/IEC , EN/IEC , EN/IEC PL e/category 4 conforming to EN/ ISO SILCL 3 conforming to EN/IEC 6206 (when connected to the appropriate module) EN/IEC , EN/IEC , EN/IEC Product certifications UL, CSA, BG UL, CSA, TÜV Supply Voltage V a and 24 c a and 24 c, 5 a, 230 a Voltage limits - 5 to + 0% - 20 to + 0% (24 V a), - 20 to + 20% (24 V c), - 5 to + 5% (5 V a), - 5 to + 0% (230 V a) Frequency Hz 50/60 Power consumption 24 V VA < 5 < 5 5 V/230 V VA < 6 Module inputs fuse protection Internal, electronic Outputs Voltage reference Relay hard contacts Number and type of safety circuits 4 N.O. (3-4, 23-24, 33-34, 43-44) 8 N.O. (3-4, 23-24, 33-34, 43-44, 53-54, 63-64, 73-74, 83-84) Number and type of additional circuits 2 N.C. (5-52, 6-62) N.C. (9-92) + solid-state Breaking capacity in AC-5 VA B300: inrush 3600, maintained 360 Breaking capacity in DC-3 24 V/.5 A to L/R = 50 ms Breaking capacity of solid-state outputs 24 V/20 ma, 48 V/0 ma Max. thermal current (Ithe) A 6 Max. total thermal current A 2 30 Output fuse protection A 6 gg Minimum current (relay contact) ma 0 (conforming to EN/IEC , VDE 0660 part 200) Minimum voltage (relay contact) V 7 Electrical life See page 6 Response time on input opening ms < 20 Rated insulation voltage (Ui) V 300 (degree of pollution 2 conforming to IEC/EN , DIN VDE 00 parts & 2) Rated impulse withstand voltage (Uimp) kv 4 (overvoltage category III, conforming to IEC/EN , DIN VDE 00 parts & 2) LED display 2 3 Operating temperature F ( C) - 3 to + 3 (- 25 to + 55) + 4 to +3 (- 0 to + 55) Storage temperature F ( C) - 3 to + 67 (- 25 to + 75) - 3 to + 85 (- 25 to + 85) Degree of protection Terminals IP 20 conforming to IEC Enclosure IP 40 Connection Type Terminals Captive screw clamp Spring terminals Captive screw clamp terminals terminals Removable from module Integrated in module -wire connection Without cable end Solid or flexible cable: 24-4 AWG (0.2 to 2.5 mm 2 ) x 2 AWG (4 mm 2 ) With cable end Without bezel, flexible cable: 24-4 AWG (0.25 to 2.5 mm 2 ) 2 x 4 AWG (2.4 mm 2 ) With bezel, flexible cable: With bezel, flexible cable: 24-6 AWG (0.25 to.5 mm 2 ) 24-4 AWG (0.25 to 2.5 mm 2 ) 2-wire connection Without cable end Solid or flexible cable: 24-8 AWG (0.2 to mm 2 ) With cable end Without bezel, flexible cable: 24-8 AWG (0.25 to mm 2 ) () Per EN/ISO and EN/IEC 6206 Double, with bezel, flexible cable: 20-6 AWG (0.5 to.5 mm 2 ) Double, with bezel, flexible cable: 20-8 AWG (0.5 to mm 2 ) page 3 Wiring diagrams: page 32 30
33 References Preventa safety relay modules types XPSECME, XPSECP For increasing the number of safety contacts References Description Number of safety circuits Additional outputs Solid-state outputs for PLC Supply Connection Reference Weight oz (kg) Safety modules for increasing the number of safety contacts, for use with XPS base modules 4 2 a and 24 V c Captive screw clamp terminals removable from module XPSECME53P (0.270) XPSECME53P a and 24 V c Spring terminals removable from module XPSECME53C (0.270) 8 a and 24 V c Captive screw clamp terminals integrated in module XPSECP (0.550) XPSECME53C 5 V a Captive screw clamp terminals integrated in module XPSECP (0.650) 230 V a Captive screw clamp terminals integrated in module XPSECP (0.650) XPSECPpppp page 30 Specifications: page 30 Wiring diagrams: page 32 3
34 Wiring diagrams Preventa safety relay modules type XPSECME For increasing the number of safety contacts XPSECME Wiring diagram L (+) z 24 V F 3 XPS Base module 4 Y2 Y A Y XPSECME K K2 A2 Y safety outputs 2 signalling outputs N ( ) Functional diagram Base module activated Relay K/K2 activated Base module deactivated Relay K/K2 deactivated Relay K/K2 Feedback loop Y-Y2 Output 3-4 (N.O.) Output (N.O.) Output (N.O.) Output (N.O.) Signalling output 5-52 (N.C.) Signalling output 6-62 (N.C.) Base module A/A2 Fuse Key 0 page 30 Specifications: page 30 page 3 32
35 Wiring diagrams Preventa safety relay modules type XPSECP For increasing the number of safety contacts XPSECP Wiring diagram L (+) F 3 23 XPS Base module 4 24 Y2 Y () A XPSECP U K B K2 U2 Y Y03 T + K A/A2 5 V 230 V K K2 K2 Fuse (2) A2 PE Y Y04 N ( ) Safety outputs Signalling output To PLC () When installing base modules and modules for increasing the number of safety contacts into different electrical enclosures, run separate cables for terminals U-3 and U-23. (2) Operating status of internal electronic fuse. Functional diagram Input A (U-K) Input B (U2-K2) Feedback loop Y-Y2 Output 3-4 (N.O.) Sortie (N.O.) Sortie (N.O.) Sortie (N.O.) Sortie (N.O.) Sortie (N.O.) Sortie (N.O.) Sortie (N.O.) Signalling output 9-92 (N.C.) Solid-state output A/A2 (fuse) Supply voltage Channel Channel 2 Channel closes closes opens Channel 2 opens Key 0 page 30 Specifications: page 30 page 3 33
36 Dimensions Preventa safety relay modules AM DP200 rail mounting Dimensions XPSACpppp, XPSAFpppp, XPSAFLpppp, XPSDMBpppp, XPSVCpppp, XPSEDA XPSACppppP, XPSABVppppP, XPSAXEppppP, XPSAFpppP, XPSAFLppppP, XPSBCEppppP, XPSBFppppP, XPSECMEppppP, XPSDMBppppP, XPSVCppppP , , XPSABVppppC, XPSAXEppppC, XPSBCEppppC, XPSECMEppppC XPSAKpppp, XPSAVpppp, XPSCMpppp, XPSDMEpppp, XPSATEpppp XPSAKppppP, XPSAVppppP, XPSCMppppP, XPSTSApppP, XPSTSWppppP, XPSDMEppppP, XPSATEppppP, XPSVNEppppP XPSBA XPSECP , Dual INCHES Millimieters 34
37 Dimensions (continued), mounting Preventa safety relay modules AM DP200 rail mounting Dimensions XPSARpppppp XPSARppppppP XPSPVT, XPSPVK Common side view XPSPVT XPSPVK XPSOT Dual INCHES Millimieters Mounting All safety relay modules: 35 mm DIN rail mounting. 35
38 General Product ratings and levels Reliability values according to standards EN/ISO and EN/IEC 6206 EN/ISO Category for the device internal Device + outputs in Stop category 0 Device + outputs in Stop category MTTF d (mean time to dangerous failure. in years) Single channel with output in Stop category 0 Single channel with output in Stop category PL (Performance Level): up to... Device + outputs in Stop category 0 Preventa safety Modules XPSABV33P e d XPSABV330P e d XPSABV33C e d XPSABV330C e d XPSAC342P e XPSAC372P e XPSAC52P e XPSAC e XPSAC e XPSAC e XPSAC e XPSAC32P e XPSAF e XPSAF530P e XPSAFL530P e XPSAFL e XPSAK3744P e XPSAK3544P e XPSAK e XPSAK e XPSAK e XPSAK e XPSAK344P e XPSAK3644P e XPSAR e XPSAR e XPSAR e XPSAR3544P e XPSAR3744P e XPSAR344P e XPSAT e d XPSAT e d XPSAT e d XPSAT50T e d XPSATE e d XPSATE50P e d XPSATE e d XPSATE340P e d XPSATE e d XPSATE370P e d XPSAV3P e e XPSAV3T e e XPSAV e e XPSAX e XPSAXE520P e XPSAXE520C e XPSBA c XPSBC e XPSBC e XPSBC e XPSBC e XPSBCE30P e XPSBCE30C e XPSBCE340P e XPSBCE340C e XPSBCE370P e XPSBCE370C e XPSBF e XPSBF32P e XPSCM44P 2.3 e XPSCM e Device + outputs in Stop category 36
39 DC (diagnostic capability) for the device internal Device + outputs in Stop category 0 Device + outputs in Stop category EN/IEC 6206 (EN/IEC 6508) PFH d (Dangerous Failure per Hour) SILCL (Safety Integrity Level Claim Level) HFT (Hardware Fault Tolerance) Device + outputs in Stop category 0 Device + outputs in Stop category Device + outputs in Stop category 0 Device + outputs in Stop category > 99 % % 3.00 x x > 99 % % 3.00 x x > 99 % % 3.00 x x > 99 % % 3.00 x x > 99 % 3.56 x > 99 % 3.56 x > 99 % 3.56 x > 99 % 3.56 x > 99 % 3.56 x > 99 % 3.56 x > 99 % 3.56 x > 99 % 3.56 x > 99 % 4.62 x > 99 % 4.62 x > 99 % 5.6 x > 99 % 5.6 x > 99 % 7.39 x > 99 % 7.39 x > 99 % 7.39 x > 99 % 7.39 x > 99 % 7.39 x > 99 % 7.39 x > 99 % 7.39 x > 99 % 7.39 x > 99 % 2.22 x > 99 % 2.22 x > 99 % 2.22 x > 99 % 2.22 x > 99 % 2.22 x > 99 % 2.22 x > 99 % 96.9 % 6.84 x x > 99 % 96.9 % 6.84 x x > 99 % 96.9 % 6.84 x x > 99 % 96.9 % 6.84 x x > 99 % 98.4 % 6.8 x x > 99 % 98.4 % 6.8 x x > 99 % 98.4 % 6.8 x x > 99 % 98.4 % 6.8 x x > 99 % 98.4 % 6.8 x x > 99 % 98.4 % 6.8 x x > 99 % > 99 % 7.95 x x > 99 % > 99 % 7.95 x x > 99 % > 99 % 7.95 x x > 99 %.90 x > 99 % 3.00 x > 99 % 3.00 x x 0-7 no SILCL 0 > 99 %.75 x > 99 %.75 x > 99 %.75 x > 99 %.75 x > 99 % 3.00 x > 99 % 3.00 x > 99 % 3.00 x > 99 % 3.00 x > 99 % 3.00 x > 99 % 3.00 x > 99 %.30 x > 99 %.30 x ,07 %.6 x ,07 %.6 x
40 General (continued) Product ratings and levels Reliability values according to standards EN/ISO and EN/IEC 6206 EN/ISO Category for the device internal Device + outputs in Stop category 0 Device + outputs in Stop category MTTF d (mean time to dangerous failure in years) Single channel with output in Stop category 0 Single channel with output in Stop category PL (Performance Level): up to... Device + outputs in Stop category 0 Preventa safety Modules (continued) XPSDMB32P e XPSDMB e XPSDME32TS e XPSDME e XPSDME32P e XPSECME53P 4 () 00 e () XPSECME53C 4 () 00 e () XPSECM343 4 () e () XPSECM53 4 () e () XPSECM373 4 () e () XPSECP53 4 () e () XPSECP343 4 () e () XPSECP373 4 () e () XPSFB e XPSFB e XPSFB e XPSFB e XPSOT () 60.9 e () XPSOT () 60.9 e () XPSPVK () 90.2 e () XPSPVK () 90.2 e () XPSPVK84 4 () 90.2 e () XPSPVT80 4 () 50.9 e () XPSTSA3442P 3 26 d XPSTSA3742P 3 26 d XPSTSA542P 3 26 d XPSTSW3742P 3 26 d XPSTSW3442P 3 26 d XPSTSW542P 3 26 d XPSVC e XPSVC32P e XPSVNE42P d XPSVNE42HSP d XPSVNE42LFP d XPSVNE3442P d XPSVNE3442HSP d XPSVNE3442LFP d XPSVNE3742P d XPSVNE3742HSP d Preventa safety controllers XPSMP23P e XPSMP e XPSMCppZp (transistor outputs) e e XPSMCppZp(Relay outputs) e e XPSMCppZp (using the relay outputs for e e Two-Hand control stations) Safety monitors and interfaces on AS-Interface cabling system ASI SAFEMON e e ASI SAFEMONB e e ASI SAFEMON e e ASI SAFEMON2B e e ASI SSLB e e ASI SSLB e e ASI SSLC e e ASI SSLC e e ASI SSLLS e e ASI SEAC e e ASI SEKC e e ASI SSLE e e ASI SSLE e e Device + outputs in Stop category () The Category, the Performance Level (PL) or the Safety Integrity Level Claim Level (SILCL) are only achieved with the full connection to the base unit or start unit. 38
41 DC (diagnostic capability) for the device internal Device + outputs in Stop category 0 Device + outputs in Stop category EN/IEC 6206 (EN/IEC 6508) PFH d (Dangerous Failure per Hour) SILCL (Safety Integrity Level Claim Level) HFT (Hardware Fault Tolerance) Device + outputs in Stop category 0 Device + outputs in Stop category Device + outputs in Stop category 0 Device + outputs in Stop category > 99 % 3.92 x > 99 % 3.92 x > 99 % 3.97 x > 99 % 3.97 x > 99 % 3.97 x % 2.00 x () % 2.00 x () 0 99 % () 7.5 x () 0 99 % () 7.5 x () 0 99 % () 7.5 x () 0 99 % () 7.5 x () 0 99 % () 7.5 x () 0 99 % () 7.5 x () > 99 %.3 x > 99 %.3 x > 99 %.3 x > 99 %.3 x % ().33 x () 0 99 % ().33 x () 0 99 % ().25 x () 0 99 % ().25 x () 0 99 % ().25 x () 0 99 % () 2.24 x () %.30 x %.30 x %.30 x %.30 x %.30 x %.30 x > 99 %.30 x > 99 %.30 x > 99 % 9.26 x > 99 % 9.26 x > 99 % 9.26 x > 99 % 9.26 x > 99 % 9.26 x > 99 % 9.26 x > 99 % 9.26 x > 99 % 9.26 x > 99 % 7.95 x > 99 % 7.95 x > 99 % > 99 %.29 x x > 99 % > 99 %.40 x x > 99 % > 99 % 2.32 x x > 99 % > 99 % 9.00 x x > 99 % > 99 % 9.00 x x > 99 % > 99 % 9.00 x x > 99 % > 99 % 9.00 x x > 99 % > 99 %.82 x x > 99 % > 99 %.82 x x > 99 % > 99 %.82 x x > 99 % > 99 %.82 x x > 99 % > 99 %.82 x x > 99 % > 99 %.82 x x > 99 % > 99 %.82 x x > 99 % > 99 %.82 x x > 99 % > 99 %.82 x x
42 Schneider Electric USA, Inc. 800 Knightdale Blvd. Knightdale, NC Tel: Waterman Avenue Toronto, Ontario M4B Y2 Tel: The information and dimensions in this catalog are provided for the convenience of our customers. While this information is believed to be accurate, Schneider Electric reserves the right to make updates and changes without prior notification and assumes no liability for any errors or omissions. Design: Schneider Electric Photos: Schneider Electric MKTED20805EN-US-SUP 200 Schneider Electric. All rights reserved. 09/200
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
mecotron Safety relay ESTOP-2 For emergency stop monitoring
E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Safety Manual BT50(T) Safety relay / Expansion relay
Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
CONFIGURABLE SAFETY RELAYS
MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional
CONFIGURABLE SAFETY RELAYS
MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate
Safety Relays ESM/ESM-F
Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
E-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous
PNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
E-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
E-STOP relays, safety gate monitors
Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring
Safety detection solutions
Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking
Contact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
Contact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
Relés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
SMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron.
Safety Relay Units G9SR family Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities industrial.omron.eu/g9sr ... A complete standalone Safety Relay Unit family - G9SR
Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
Pendant control stations 6
Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
Actuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
Manual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
E-STOP relays, safety gate monitors
Unit features Unit description Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),
Type: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
Catalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
Universal Voltage Terminal Photoelectric E3JM
Universal Voltage Terminal Photoelectric Universal AC/DC Photoelectric Sensor with Built-in Timer Easy-to-wire terminal block Built-in timer offers selectable ON-delay, OFF-delay and one-shot Relay or
49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
Bimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
Technicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP
Programmable Safety controllers g9sp G9SP compact Stand-Alone Programmable controller Stand-alone safety controller for small and mid-sized machinery Easy programming for complex safety control Three types
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011
, 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10
ABB ABB Schweiz AG Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205 09.04.2014 Page: 8201 Schaffhausen 1 / 10 Please use also the assembly instruction S800-RSU-H Remote
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
Manual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
PROTECT. Safety Relay Modules PROTECT-SRB s Catalogue Protect/04
PROTECT Safety Relay Modules PROTECT-SRB s Catalogue Protect/04 Subject to technical modifications and error. The data specified in this catalogue are carefully checked typical standard values. Or as the
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs
E L E K T R O N I K Appliance Description Programmable safety center FPSC Fiessler Programmable Safety Center Flexible Hard- and Software concept Available with a safe bus system or/and two counter inputs
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Technical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
Safety dialogue solutions
General Presentation Emergency stop trip wire switches Emergency stop trip wire switches are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
Speed Control Relays SX2
SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................
General 1-2-Opto-electronics Safety Switches 4-Emergency
General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection