Technical catalogue - Ordering Codes. SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated



Similar documents
Technical catalogue SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A

General information Circuit breakers for power distribution T1 T3

Brochure April Moulded-case circuit-breakers overview SACE Tmax

Technical catalog - Edition SACE Tmax PV Adaptability, versatility and complete freedom continue

Tmax. Technical catalogue. Low voltage moulded-case circuit-breakers up to 630 A 1SDC210004D0204

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Technical catalog. FORMULA UL New low voltage molded case circuit breakers up to 250A. Power and productivity for a better world TM

Emax DC. Annex to the technical catalogue. Low voltage Switch-disconnectors and Automatic circuit-breakers for Direct Current Applications

White paper. ABB solutions for switching and protection of low speed wind turbines

Breaking and protection devices

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Tmax MCCBs. Molded case circuit breakers. Tmax

Index Molded case circuit breakers. Molded case circuit breakers. Tmax UL489B Photovoltaic circuit breakers

Spare parts Catalogue

R.C.C.B. s two-pole LEXIC

Low Voltage Products. Switches Automatic Transfer Switches

White Paper - July ATS021-ATS022 Automatic transfer switching

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Unified requirements for systems with voltages above 1 kv up to 15 kv

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

The complete range of consumer switchboards and switchgear

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Catalogue. Merlin Gerin Compact LV circuit breakers and switch-disconnectors 80 to 3200A

more than a breaker it s a breakthrough Compact NSX

Working with the Trip Characteristic Curves of ABB SACE Low Voltage Circuit-Breakers 1SDC007400G0201

White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection

Electronic overload relay EF19 and EF45

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Tmax. Molded case circuit breakers. Phone: Fax: Web: info@clrwtr.com. Tmax.

Voltage Regulator SPAU 341 C. Product Guide

Technical catalogue. Low-voltage moulded-case circuit-breakers /012 en ABB SACE

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Technical catalogue. Low voltage air circuit-breakers. SACE Emax /011 en March ' V A ka (380/415 V) ABB SACE L.V.

Electronic overload relay EF65, EF96 and EF146

Manual motor starter MS116

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Technical catalogue. Emax Low voltage air circuit-breakers

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Low voltage circuit breakers. Working with trip characteristic curves

Remote Monitoring and REC 501 Control Unit Product Guide

Manual Motor Starter MS 116 up to 16 A Technical Data

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120

Catalogue May EasyLine XLP Fuse Switch Disconnector pole

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

UFES Active protection for switchgear

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Low Voltage. EasyPact CVS. Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A. Catalogue 2011

Circuit Breakers. Next Generation of Protection Capabilities

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

IZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors

Environmental Product Declaration. Registration number: S-P Rev. 0 11/06/03. Tmax T1. Low voltage circuit breaker.

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Bulletin 150 SMC Flex Smart Motor Controller Specifications

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Technical catalogue. Modular DIN rail components Installation contactors

T Substation Maintenance and Commissioning Test Equipment

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Maximum Demand Control

Thermal-Magnetic Circuit Breaker M1-..

Motor circuit-breakers

Merlin Gerin Multi 9 System Protection Miniature Circuit Breakers

Circuit Breaker. Description

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Molded case circuit breakers

Quick Connect. quick - simple - efficient.

Three-phase monitoring relay CM-PFE

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

SENTRON Switching and Protection Devices Air Circuit Breakers

Safety automation solutions

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

ABB circuit breakers for direct current applications

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Wiring diagrams. Compact NSX. Contents

Products and solutions for lifting systems

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Medium Voltage Products. PR512 Microprocessor-based self-supplied protection relays

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Current and voltage measuring relays

SURGE PROTECTIVE DEVICES

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM

DS 600. A contact free flux gate based current measurement sensor 600A rms

Catalog. Arc Guard System TM TVOC-2

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Transcription:

Technical catalogue - Ordering Codes SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated

New SACE Tmax XT. Simply XTraordinary. Today a highly advanced range of circuit-breakers has been brought out, with unparalleled versatility of use and able to solve all installation problems brilliantly. You can find the new SACE Tmax XT in the three-pole and four-pole, fixed, plug-in and withdrawable versions, fitted with the very latest generation thermomagnetic and electronic trip units, with the possibility of interchangeability. The new SACE Tmax XT set up a new technological standard and leave you free to think up and build installations with extraordinary performances. An extraordinary demonstration of ABB SACE s innovation capability. Extraordinary latest generation electronics. Extraordinary coverage of all plant requirements. Extraordinary performances in compact dimensions. Extraordinary simplicity of installation and putting into service. Extraordinary range of accessories available. This publication presents the Tmax XT circuit breakers up to 250A with thermomagnetic trip unit calibrated at 50 C. The breakers Tmax XT with electronic trip unit are suitable for 50 C without derating. For other versions and common accessories, please refer to the Tmax XT catalogue. New SACE Tmax XT. Simply XTraordinary.

Identification of the SACE Tmax XT 50 C Circuit-breakers The characteristics of the circuit-breaker are given on the rating nameplate on the front of the circuit-breaker, and on the side rating plate. Front label 1 7 4 3 7 6 5 14 10 11 1 9 15 13 8 12 1 2 7 7 6 5 14 15 6 10 9 3 4 13 1 Name of the circuit-breaker and performance level (*) 2 In: rated current of the circuit-breaker (*) 3 Uimp: rated impulse withstand voltage (*) 4 Ui: insulation voltage (*) 5 Ics rated short-circuit duty breaking capacity (*) 6 Icu: rated ultimate short-circuit breaking capacity (*) 7 Ue: rated service voltage (*) 8 Symbol of isolation behaviour (*) 9 Reference Standard IEC 60947-2 (*) 10 Serial number 11 Anti-forgery logo 12 Test pushbutton 13 CE marking 14 Utilisation Category 15 Reference Standard NEMA-AB1 (*) In compliance with the IEC 60947-2 Standard 1

Circuit-breakers for power distribution 50 C Main characteristics SACE Tmax XT moulded-case circuit-breakers are the ideal solution for all distribution levels, from the main low voltage switchboard to the subswitchboards in the installation. They feature high specifi c let-through current peak and energy limiting characteristics that allow the circuits and equipment on the load side to be sized in an optimum way. SACE Tmax XT circuit-breakers with thermomagnetic and electronic trip units protect against overloads, short-circuits, earth faults and indirect contacts in low voltage distribution networks. The SACE Tmax XT family of moulded-case circuit-breakers can be equipped with: thermomagnetic trip units for direct and alternating current network protection, using the physical properties of a bimetal and an electromagnet to detect the overloads and short-circuits. They are calibrated at a reference temperature of 50 C. Please refer to the Tmax XT main catalogue for the trip curves. electronic trip units for alternating current network protection. Releases with microprocessor technology obtain protection functions that make the operations extremely reliable and accurate. The power required for operating them correctly is supplied straight from the current sensors of the releases. This ensures that they trip even in single-phase conditions and on a level with the minimum setting. Circuit breakers with electronic trip units are suitable for use at 50 C without derating. For technical characteristics and ordering codes please refer to the main Tmax XT catalogue. Characteristics of Electronic trip units SACE Tmax XT Operating temperature -25 C +70 C Relative humidity 98% Self-supplied (1) (2) 0.2xIn (single phase) Auxiliary supply (where applicable) 24V DC ± 20% Operating frequency 45 66Hz or 360 440Hz Electromagnetic compatibility IEC 60947-2 Annex F (1) 0.32 x In for Ekip N-LS/I (2) For 10A: 0.4In Example with XT2 125A Rotary switch for magnetic protection setting Rotary switch for thermal protection setting Example with XT3 250A Rotary switch for thermal protection setting 2

Circuit-breakers for power distribution 50 C Thermomagnetic trip units TMD (XT1 - XT3) Main characteristics: protections: against overload (L): adjustable protection threshold from 0.7...1xIn, with inverse long-time trip curve; against instantaneous short-circuits (I): fi xed 10xIn protection threshold, with instantaneous trip curve; 100% neutral protection in four-pole circuit-breakers. 50% neutral protection is only available for In 125A; TMD/TMA (XT2) Main characteristics: protections: against overload (L): adjustable protection threshold from 0.7...1xIn, with inverse long time trip curve; against instantaneous short-circuit (I): - fi xed protection threshold for In 32A, - adjustable threshold beteewn 8 10xIn for 40A, - adjustable threshold beteewn 6 10xIn for 50A, - adjustable threshold beteewn 5 10xIn for In 63A; 100% neutral protection in four-pole circuit-breakers. 50% neutral protection is only available for In 125A; XT1 TMD Breaking capacity C C,N C,N C,N C,N C,N C,N C,N C,N In [A] 25 32 40 50 63 80 100 125 150 Neutral [A] - 100% 25 32 40 50 63 80 100 125 150 I 1 = 0.7 1xIn Neutral [A] - 50% 80 100 [A] 450 450 450 500 630 800 1000 1250 1500 Neutral [A] - 100% 450 450 450 500 630 800 1000 1250 1500 = 10xIn Neutral [A] - 50% 800 1000 XT2 TMD/TMA In [A] 16 20 25 32 40 50 63 80 100 125 Neutral [A] - 100% 16 20 25 32 40 50 63 80 100 125 I 1 = 0.7 1xIn Neutral [A] - 50% 80 TMD 300 300 300 320 TMA 300 400 Neutral [A] - 100% 300 300 300 320 300 400 Neutral [A] - 50% 400 800 (1) Available only as complete circuit-breaker 300 500 300 500 300 630 300 630 400 800 400 800 500 1000 500 1000 625 1250 625 1250 XT3 TMD Breaking capacity N,S N,S C,N,S C,N,S C,N,S C,N,S C,N,S In [A] 63 80 100 125 160 200 250 Neutral [A] - 100% 63 80 100 125 160 200 250 I 1 = 0.7 1xIn Neutral [A] - 50% 80 100 125 160 [A] 630 800 1000 1250 1600 2000 2500 Neutral [A] - 100% 630 800 1000 1250 1600 2000 2500 = 10xIn Neutral [A] - 50% 800 1000 1250 1600 3

Circuit-breakers for motors protection 50 C Magnetic trip units MF/MA Main characteristics: available for XT2, XT3 and XT4 in the three-pole version only, these trip units are mainly used for protecting motors, in conjunction with a thermal relay and a contactor; protections: against instantaneous short-circuit (I) for XT2: for In 12.5A the protection threshold I is fi xed at 14xIn, whereas for In>12.5A the protection threshold I is adjustable from 6..14xIn; against instantaneous short-circuit (I) for XT3: the protection threshold I is adjustable from 6..12xIn; against instantaneous short-circuit (I) for XT4: the protection threshold I is adjustable from 5..10xIn; the magnetic protection setting is made by turning the relative cursor on the front of the release. for ordering codes refer to the main Tmax XT catalogue. the circuit-breakers MF/MA for motor protection are suitable for use at 50 C without derating. Rotary switch for magnetic protection setting XT2 MF/MA = 14xIn [A] = 6..14xIn [A] In [A] 1 (1) 2 (1) 4 (1) 8.5 (1) 12.5 (1) 20 32 52 80 100 = MF 14 28 56 120 175 = MA 120...280 192 448 314 728 480 1120 600...1400 (1) Available only as complete circuit-breaker XT3 MA = 6..12xIn XT4 MA = 5..10xIn In [A] 100 125 160 200 [A] 600 1200 750 1500 960 1920 1200 2400 In [A] 10 (1) 12.5 (1) 20 32 52 80 100 125 160 200 [A] 50 100 62.5 125 100 200 160 320 260 520 400 800 500 1000 625 1250 800 1600 1000 2000 (1) Available only as complete circuit-breaker 4

Switch-disconnectors 50 C Main characteristics XT1D XT3D The switch-disconnector (or, in short, disconnector) is a device created from the corresponding circuit-breakers (of which it features the same overall dimensions, versions, fastening mechanisms and ability to be fi tted with accessories). The main function of these devices is to disconnect the circuit they are installed in. In the open position, the disconnector disconnects and guarantees a suffi cient insulation distance (between the contacts) to assure safety and to prevent an electrical arc from striking. The switch-disconnectors are suitable for use at 50 C without derating. Applications Switch-disconnectors are generally used as: general disconnectors of subswitchboards; operating and disconnecting devices for lines, pan-assembliess or groups of equipment; bus-ties; general disconnecting devices for groups of machines; general group disconnecting devices for motor operation and protection; insulation of small tertiary distribution units. Protection A disconnector is unable to automatically break the short-circuit or overload current. For this reason, each switch-disconnector must be protected on the supply side by a coordinated device that safeguards it against short-circuits. The circuit-breaker able to act as a protection for each switch-disconnector is indicated in the table below. XT4D Category of use The CEI EN 60947-3 Standard defi nes the utilisation categories for disconnectors in accordance with the table below. Tmax XT disconnectors comply with the AC21A, AC22A and AC23A utilisation categories. Class of use Infrequent operation Frequent operation Typical applications AC-21A AC-21B Control of resistive loads with overloads of modest entity AC-22A AC-22B Control of mixed resistive and inductive loads with overloads of modest entity AC-23A AC-23B Control of motors or other highly inductive loads Characteristics of switch-disconnectors XT1D XT3D XT4D Size [A] 160 250 250 Rated operating current in class AC21, Ie [A] 160 250 250 Rated operating current in class AC22, Ie [A] 160 250 250 Rated operating current in class AC23, Ie [A] 125 200 200 Poles [Nr.] 3, 4 3, 4 3, 4 Rated service voltage, Ue (AC) 50-60Hz [V] 690 690 690 (DC) [V] 500 500 500 Rated insulation voltage, Ui [V] 800 800 800 Rated impulse withstand voltage, Uimp [kv] 8 8 8 Test voltage at industrial frequency for 1 min [V] 3000 3000 3000 Rated breaking capacity (Min) Disconnector only [ka] 2.8 5.3 5.3 in short-circuit, Icm (Max) With automatic [ka] 154 105 105 circuit-breaker on supply side Rated short-time withstand current for 1s, Icw [ka] 2 3 3.6 Versions Fixed, Plug-in Fixed, Plug-in Fixed, Withdrawable, Plug-in 5

Ordering codes 50 C Power distribution circuit-breakers XT1C 160 TMD (50 C) - Fixed (F) - Front terminals (F) Icu (415V) = 25kA Thermomagnetic trip unit - TMD In XT1C 160 TMD 25-450 F F 50 C 25 450 070083 070092 XT1C 160 TMD 32-450 F F 50 C 32 450 070084 070093 XT1C 160 TMD 40-450 F F 50 C 40 450 070085 070094 XT1C 160 TMD 50-500 F F 50 C 50 500 070086 070095 XT1C 160 TMD 63-630 F F 50 C 63 630 070087 070096 XT1C 160 TMD 80-800 F F 50 C 80 800 070088 070097 XT1C 160 TMD 100-1000 F F 50 C 100 1000 070089 070098 XT1C 160 TMD 125-1250 F F 50 C 125 1250 070090 070099 XT1C 160 TMD 150-1500 F F 50 C 150 1500 070091 070100 XT1N 160 TMD (50 C) - Fixed (F) - Front terminals (F) Icu (415V) = 36kA Thermomagnetic trip unit - TMD In XT1N 160 TMD 32-450 F F 50 C 32 450 070101 070109 XT1N 160 TMD 40-450 F F 50 C 40 450 070102 070110 XT1N 160 TMD 50-500 F F 50 C 50 500 070103 070111 XT1N 160 TMD 63-630 F F 50 C 63 630 070104 070112 XT1N 160 TMD 80-800 F F 50 C 80 800 070105 070113 XT1N 160 TMD 100-1000 F F 50 C 100 1000 070106 070114 XT1N 160 TMD 125-1250 F F 50 C 125 1250 070107 070115 XT1N 160 TMD 150-1500 F F 50 C 150 1500 070108 070116 XT2N 160 TMD/TMA (50 C) - Fixed (F) - Front terminals (F) Icu (415V) = 36kA Thermomagnetic trip unit - TMD/TMA In XT2N 160 TMD 16-300 F F 50 C 16 300 070117 070127 XT2N 160 TMD 20-300 F F 50 C 20 300 070118 070128 XT2N 160 TMD 25-300 F F 50 C 25 300 070119 070129 XT2N 160 TMD 32-320 F F 50 C 32 320 070120 070130 XT2N 160 TMA 40-400 F F 50 C 40 400 070121 070131 XT2N 160 TMA 50-500 F F 50 C 50 500 070122 070132 XT2N 160 TMA 63-630 F F 50 C 63 630 070123 070133 XT2N 160 TMA 80-800 F F 50 C 80 800 070124 070134 XT2N 160 TMA 100-1000 F F 50 C 100 1000 070125 070135 XT2N 160 TMA 125-1250 F F 50 C 125 1250 070126 070136 6

Ordering codes 50 C Power distribution circuit-breakers XT2S 160 TMD/TMA (50 C) - Fixed (F) - Front terminals (F) Icu (415V) = 50kA Thermomagnetic trip unit - TMD/TMA In XT2S 160 TMD 16-300 F F 50 C 16 300 070137 070147 XT2S 160 TMD 20-300 F F 50 C 20 300 070138 070148 XT2S 160 TMD 25-300 F F 50 C 25 300 070139 070149 XT2S 160 TMD 32-320 F F 50 C 32 320 070140 070150 XT2S 160 TMA 40-400 F F 50 C 40 400 070141 070151 XT2S 160 TMA 50-500 F F 50 C 50 500 070142 070152 XT2S 160 TMA 63-630 F F 50 C 63 630 070143 070153 XT2S 160 TMA 80-800 F F 50 C 80 800 070144 070154 XT2S 160 TMA 100-1000 F F 50 C 100 1000 070145 070155 XT2S 160 TMA 125-1250 F F 50 C 125 1250 070146 070156 XT3C 250 TMD (50 C) - Fixed (F) - Front terminals (F) Icu (415V) = 25kA Thermomagnetic trip unit - TMD In XT3C 250 TMD 100-1000 3p F F 50 C 100 1000 081814 XT3C 250 TMD 125-1250 3p F F 50 C 125 1250 081815 XT3C 250 TMD 160-1600 3p F F 50 C 160 1600 081816 XT3C 250 TMD 200-2000 3p F F 50 C 200 2000 081817 XT3C 250 TMD 250-2500 3p F F 50 C 250 2500 081818 XT3N 250 TMD (50 C) - Fixed (F) - Front terminals (F) Icu (415V) = 36kA Thermomagnetic trip unit - TMD In XT3N 250 TMD 63-630 F F 50 C 63 630 070157 070164 XT3N 250 TMD 80-800 F F 50 C 80 800 070158 070165 XT3N 250 TMD 100-1000 F F 50 C 100 1000 070159 070166 XT3N 250 TMD 125-1250 F F 50 C 125 1250 070160 070167 XT3N 250 TMD 160-1600 F F 50 C 160 1600 070161 070168 XT3N 250 TMD 200-2000 F F 50 C 200 2000 070162 070169 XT3N 250 TMD 250-2500 F F 50 C 250 2500 070163 070170 XT3S 250 TMD (50 C) - Fixed (F) - Front terminals (F) Icu (415V) = 50kA Thermomagnetic trip unit - TMD In XT3S 250 TMD 63-630 F F 50 C 63 630 070171 070178 XT3S 250 TMD 80-800 F F 50 C 80 800 070172 070179 XT3S 250 TMD 100-1000 F F 50 C 100 1000 070173 070180 XT3S 250 TMD 125-1250 F F 50 C 125 1250 070174 070181 XT3S 250 TMD 160-1600 F F 50 C 160 1600 070175 070182 XT3S 250 TMD 200-2000 F F 50 C 200 2000 070176 070183 XT3S 250 TMD 250-2500 F F 50 C 250 2500 070177 070184 7

Ordering codes 50 C Switch-disconnectors XT1D 160 - Fixed (F) - Front terminals (F) Icw = 2 ka XT1D 160 F F 068208 068209 XT3D 250 - Fixed (F) - Front terminals (F) Icw = 3 ka XT3D 250 F F 068210 068211 XT4D 250 - Fixed (F) - Front terminals (F) Icw = 3.6 ka XT4D 250 F F 068212 068213 Ordering codes Common accessories Uncabled SOR - PS SOR - UVR Cabled SOR - PS SOR - UVR Direct rotary handle (RHD) Transmitted rotary handle (RHE) Fixed padlock 1SDA...R1 Shunt Opening release (SOR) SOR 110...127V AC / 110...125V DC uncabled version 066316 SOR 220...240V AC / 220...250V DC uncabled version 066317 SOR-C 110-127V AC / 110-125V DC cabled version 066324 SOR-C 220-240V AC / 220-250V DC cabled version 066325 Undervoltage release (UVR) UVR 110...127V AC / 110...125V DC uncabled version 066391 UVR 220...240V AC / 220...250V DC cabled version 066392 UVR-C 110-127V AC / 110-125V DC cabled version 066398 UVR-C 220-240V AC / 220-250V DC cabled version 066399 Auxillary Contacts (Aux) AUX 250V AC uncabled version 066422 AUX-C 1Q+1SY 250V cabled version 066431 AUX-C 2Q+1SY 250V cabled version 066433 Rotary Handles RHD Normal Direct Handle (XT1/XT3) 066475 RHE Normal Transmitted Handle (XT1/XT3) 066479 RHD Normal Direct Handle (XT2/XT4) 069053 RHE Normal Transmitted Handle (XT2/XT4) 069055 Motor Operator MOD 220...250V AC/DC (XT1/XT3) 066460 MOE 220...250V AC/DC (XT2/XT4) 066466 Padlock on the circuit breaker PLL Fixed lock with padlocks in open position (XT1/XT3) 066589 PLL Fixed lock with padlocks in open/closed position (XT1/XT3) 066591 PLL Fixed lock with padlocks in open position (XT2/XT4) 066590 PLL Fixed lock with padlocks in open/closed position (XT2/XT4) 066592 8 Note: Above accessories refer to the breakers in fixed version. For a complete list of available accessories please refer to the main Tmax XT catalogue.

Ordering codes 50 C Terminals XT1 Terminals Type 3 pcs 4 pcs 6 pcs 8 pcs FC CuAl Terminals for CuAl cables 1x1.5...50mm 2 067151 067152 067153 067154 FC CuAl Terminals for CuAl cables 1x35...95mm 2 067155 067156 067157 067158 FC CuAl Terminals for CuAl cables 1x120...240mm 2 + ADP 067159 067160 067161 067162 FC Cu Terminals for Cu cables 066905 066906 066907 066908 EF Extended front terminals 066865 066866 066867 066868 ES Extended spread front terminals 066889 066890 066891 066892 R Rear Adjustable Terminals 066937 066938 066939 066940 R-RC Rear terminals for Residual current 066953 XT2 Terminals Type 3 pcs 4 pcs 6 pcs 8 pcs FC CuAl Terminals for CuAl cables 1x1...95mm 2 067163 067164 067165 067166 FC CuAl Terminals for CuAl cables 1x70...185mm 2 067167 067168 067169 067170 FC CuAl Terminals for CuAl cables 1x120 240mm 2 + ADP 067171 067172 067173 067174 FC CuAl Terminals for CuAl cables 2x35...95mm 2 067175 067176 067177 067178 FC Cu Terminals for Cu cables 066909 066910 066911 066912 EF Extetnded front terminals 066869 066870 066871 066872 ES Extended spread front terminals 066893 066894 066895 066896 R Rear adjustable Terminals 066941 066942 066943 066944 XT3 Terminals Type 3 pcs 4 pcs 6 pcs 8 pcs FC CuAl terminals for CuAl cables 1x95...185mm2 067179 067180 067181 067182 FC CuAl terminals for CuAl cables 1x120...240mm2 + ADP 067183 067184 067185 067186 FC CuAl terminals for CuAl cables 2x35...150mm2 067187 067188 067189 067190 FC CuAl terminals for CuAl cables 1x35...150mm2 066274 066930 066584 066586 FC Cu terminals for Cu cables 066913 066914 066915 066916 EF Extetnded front terminals 066873 066874 066875 066876 ES Extended spread front terminals 066897 066898 066899 066900 R Rear adjustable terminals 066945 066946 066947 066948 Note on ordering codes: Please refer to the main Tmax XT catalogue for the complete list of accessories like kit for plug-in or draw-out, fixed parts and more. 9

Contact us ABB SACE A division of ABB Low Voltage Breakers Via Pescaria, 5 24123 Bergamo Phone: +39 035 395 111 Fax: +39 035 395 306-433 ABB Regional Sales Organization Southern Gulf Dubai ABB LLC Low Voltage Products Regional Head Office Al Quoz Industrial Area 3, Dubai Tel: +971 4 314 7500 Fax: +971 4 340 1541 Bahrain ABB Technologies WLL Low Voltage Products Bldg. No 175, Road 4304, Block 343, Mina Salman, Manama Kingdom of Bahrain Tel: +973 178 10666 Fax: 973 1772 5332 Oman ABB LLC Low Voltage Products 305, Hatat Complex B, PO Box 778, PC 131, Muscat, Oman Tel: +968 2 466 6500 Fax: +968 2 466 6590 Qatar ABB LLC Low Voltage Products HSBC Building, 150 Al Matar Street (Airport Road) Umm Ghuwailina, Doha Tel: +974 4 425 3888 Fax: +974 4 431 2630 The data and illustrations are not binding. We reserve the right to modify the contents of this document on the basis of technical development of the products, without prior notice. Copyright 2015 ABB. All rights reserved. 1SDC210064D0201 2015.09-1000 - CAL - Printed in UAE Kuwait ABB Engineering Technologies Co. (KSCC) Low Voltage Products Alghunaim Commercial Tower 5th Floor, Al Qibla Area, Abu Baker Al-Sadique Street, Kuwait City PO Box 4275, Safat 13043, Kuwait Tel: +965 2227 7865 Fax: +965 2227 7800