1 Merlin Gerin Multi 9 System Protection Miniature Circuit Breakers Get more with the world s Power & Control specialist
2 Protection Merlin Gerin Multi 9 System Miniature circuit breakers Tripping curves Markings & limitation capability Trip Unit Variations Circuit Protection A choice of several curves Whatever circuit has to be protected, a C60 or C120 circuit breaker provides the perfect solution with a suitable curve. Curve B tripping: 3 to 5 times the rated current (In); protection of generators, persons, very long cables. 1 Curve C tripping: 5 to 10 In; protection of circuits, general applications Curve D tripping: 10 to 14 In; protection of high surge circuits, welders, transformers, motors. Curve MA (magnetic only) tripping: 12 In; protection of motor starters (+ thermal protection when combined with contactor). Circuit Breaker Marking multi 9 C60H C63 415V~ Circuit Breaker Model Number 2. Tripping Curve 3. Circuit Breaker Current Rating 4. Operating Voltage 5. Rated Breaking Capacity 6. Circuit Breaker Part Number 7. Electrical Diagram - No. of Poles 8. I 2 t classification Circuit Breaker Limitation Capability The limitation capability of a circuit breaker is that characteristic whereby only a current less than the prospective fault current is allowed to flow under short-circuit conditions. This is illustrated by limitation curves which give: " The limited peak current in relation to the RMS value of the prospective short-circuit current (the short-circuit current being that current which would flow continuously in the absence of protection equipment). " The limited current stress in relation to the RMS value of the prospective short-circuit current. " Current limiting capability. The advanced design of the Multi-9 range provides current limitation with far better protection than conventional circuit breakers. For example, on a 6A rating with a prospective short circuit of 5000A, the current will be limited at 350A or 7%. Installation of current limiting circuit breakers offers several advantages: # Better network protection Current limiting circuit breakers considerably reduce the undesirable effects of short-circuit currents in an installation. # Reduced thermal effects Cable heating is reduced, hence longer cable life. # Reduced mechanical effects Electrodynamic forces reduced, thus electrical contacts are less likely to be deformed or broken. # Reduced electromagnetic effects Measuring equipment situated near an electrical circuit less affected.
3 Miniature Circuit Breakers up to 63A Page 18mm pole width C60a 4.5kA 2 C60N 6kA 3 C60H 10kA 4 C32H-DC 10kA 18 (circuit breakers for DC applications) electrical auxiliaires C60 10 accessories C60 16 Miniature Circuit Breakers up to 125A 27mm pole width C120N 10kA 6 C120H 15kA 8 electrical auxiliaries C accessories C Tm Motor Mechanism TM C60/C Dimensions 23 For supplementary technical information, consult AUS Page 1
4 circuit-breakers up to 63 A C60a circuit-breakers 4.5 ka, C curve AS/NZS 4898 Approval No: N13634 functions The circuit-breakers combine the following functions: - protection of circuits against short-circuit currents, - protection of circuits against overload currents, - control, - isolation, - protection of persons against indirect contact. - C60a circuit-breakers are used in the domestic sectors where single phase fault levels are less than or equal to 4.5kA. description technical data C60a circuit-breakers v voltage rating: 240 V AC v number of cycles (O-C): v foolproof terminal design - moving barrier prevents incorrect cable insertion - cable strand centering guides ensure correct cable positions and strand grouping v isolation with positive contact indication v bistable din clip, simplifies disassembly c environment v tropicalisation: treatment 2 (relative humidity: 95 % at 55 C) v connection: tunnel terminals for the following cables: - up to 25A : 25mm 2 stranded - 32 to 63A : 35mm 2 stranded C curve utilisation cables feeding conventional loads. technical data v tripping curves: the magnetic trip unit operates between 5 and 10 In v breaking capacity - according to AS/NZS 4898 Icu ultimate breaking capacity (0-C0 cycle): rating voltage breaking (A) (V) capacity Icu (A) catalogue numbers type rating catalogue width quantity (A) number in mod. per box of 9 mm C curve C60a 1P Page 2 Schneider Electric Help Centre:
5 circuit-breakers up to 63 A C60N circuit-breakers 6kA, C curve AS/NZS 4898 Approval No: N13634 functions The circuit-breakers combine the following functions: - protection of circuits against short-circuit currents, - protection of circuits against overload currents, - control, - isolation, - protection of persons against indirect contact. description technical data common to C60N circuit breakers v voltage rating: 240/415 V AC - for 2P single phase 240/480V v I 2 t classification: 3 v number of cycles (O-C): v foolproof terminal design - moving barrier prevents incorrect cable insertion - cable strand centering guides ensure correct cable positions and strand grouping v isolation with positive contact indication v bistable din clip, simplifies disassembly c environment v tropicalisation: treatment 2 (relative humidity: 95 % at 55 C) v connection: tunnel terminals for the following cables: - up to 25A : 16mm 2 flexible with cable end : 25mm 2 stranded - 32 to 63A : 25mm 2 flexible with cable end : 35mm 2 stranded C curve utilisation cables feeding conventional loads. technical data v tripping curves: the magnetic trip units operate between 5 and 10 In v breaking capacity according to AS/NZS 4898, Icu ultimate breaking capacity (O-CO cycle): rating type voltage breaking capacity (A) (V) Icu (A) P 240/ P P catalogue numbers type rating catalogue (A) number C curve C60N P Width in mod of 9mm P Width in mod of 9mm P Width in mod of 9mm Page 3
6 circuit-breakers up to 63 A C60H circuit-breakers 10kA, B, C and D curves AS/NZS 4898 Approval No: N13634 functions description The circuit-breakers combine the following functions: - protection of circuits against short-circuit currents, - protection of circuits against overload currents, - control, technical data common to C60H circuit-breakers v voltage rating: 240/415 V AC v breaking capacity - according to AS/NZS 4898, Icv ultimate breaking capacity (O-CO cycle): rating type voltage break. cap. (A) (V) Icu (A) P, 2P 240/ P, 4P v I 2 t classification: 3 v foolproof terminal design - moving barrier prevents incorrect cable insertion - cable strand centering guides ensure correct cable positions and strand grouping v isolation with positive contact indication v bistable din clip, simplifies disassembly v isolation with positive contact indication: opening is indicated by a green strip on the device operating handle. This indicator shows opening of all the poles v number of cycles (O-C): c environment v tropicalisation: treatment 2 (relative humidity: 95 % at 55 C) v connection: tunnel terminals for the following cables: - up to 25A :16mm 2 flexible with cable end; 25mm 2 stranded - 32 to 63A :25mm 2 flexible with cable end; 35mm 2 stranded - isolation, - protection of persons against indirect contact. B curve utilisation when there are small inrush currents (generators, long cables). technical data v tripping curve: the magnetic trip units operate between 3 and 5 In. C curve utilisation cables feeding conventional loads. technical data v tripping curve: the magnetic trip units operate between 5 and 10 In. D curve utilisation loads with a high inrush current (motors, transformers). technical data v tripping curve: the magnetic trip units operate between 10 and 14 In. Page 4 Schneider Electric Help Centre:
7 circuit-breakers up to 63 A C60H circuit-breakers 10kA, B, C and D curve AS/NZS 4898 Approval No: N13634 catalogue numbers type rating B C D (A) Curve Curve Curve C60H P Width in mod of 9mm P Width in mod of 9mm P Width in mod of 9mm P Width in mod of 9mm Page 5
8 circuit breakers up to 125A C120N circuit-breakers 10kA, B, C curves - AS/NZS kA, D curve AS function The circuit-breakers combine the following functions: - protection of circuits against short circuit currents, - protection of circuits against overload currents, - control, - isolation, - protection of persons against indirect contact. description Technical data common to C120N circuit breakers v current rating: 63 to 125 A v voltage rating 415 V AC v insulation voltage Ui: 500 V v impulse withstand voltage Uimp: 6 kv v breaking capacity: - according to AS/NZS 4898 Icv ultimate breaking capacity (O-CO cycle) type voltage breaking cap. (V) Icu (A) 1, 2, 3, 4P 240/ v according to AS Icu ultimate breaking capacity (O-CO cycle) type voltage breaking cap. (V) Icu (ka) 1P , 3, 4P v mechanical durability: cycles (O-C) v electrical durability: - 63 A: cycles (O-C) A: 5000 cycles (O-C) v I 2 t classification: 3 v isolation with positive contact indication: opening is indicated by a green strip on the device operating handle. This indicator shows opening of all the poles v foolproof terminal design - moving barrier prevents incorrect cable insertion - cable strand centering guides ensure correct cable positions and strand grouping v bistable din clip: simplifies disassembly v 63 to 125A: - up to 35mm 2 flexible with cable end - up to 50mm 2 stranded B curve Approval No:Q00542 utilisation when there are small inrush currents (generators, long cables). technical data v tripping curve: the magnetic trip units operate between 3 and 5 In. C curve utilisation cables feeding conventional loads. technical data v tripping curve: the magnetic trip units operate between 5 and 10 In. D curve - For industrial use only utilisation loads with a high inrush current (motors, transformers). technical data Approval No:Q00542 v tripping curve: the magnetic trip units operate between 10 and 14 In. Page 6 Schneider Electric Help Centre:
9 circuit-breakers up to 125 A C120N circuit-breakers 10kA, B, C curves - AS/NZS kA, D curve AS catalogue numbers type rating B C D (A) Curve Curve Curve B curve C120N 1P Width in mod of 9mm - 3 2P Width in mod of 9mm - 6 3P Width in mod of 9mm - 9 4P Width in mod of 9mm - 12 Page 7
10 circuit breakers up to 125A C120H circuit-breakers 15kA, B, C curves - AS/NZS kA, D curve AS function The circuit-breakers combine the following functions: - protection of circuits against short circuit currents, - protection of circuits against overload currents, - control, - isolation, - protection of persons against indirect contact. description Technical data common to C120N circuit breakers v current rating: 10 to 125 A v voltage rating 415 V AC v insulation voltage Ui: 500 V v impulse withstand voltage Uimp: 6 kv v breaking capacity: - according to AS/NZS 4898 Icu ultimate breaking capacity (O-CO cycle) type voltage breaking cap. (V) Icu (A) 1, 2, 3, 4P 240/ v according to AS Icu ultimate breaking capacity (O-CO cycle) type voltage breaking cap. (V) Icu (ka) 1P , 3, 4P v mechanical durability: cycles (O-C) v electrical durability: - 63 A: cycles (O-C) A: 5000 cycles (O-C) v I 2 t classification: 3 v isolation with positive contact indication: opening is indicated by a green strip on the device operating handle. This indicator shows opening of all the poles v foolproof terminal design - moving barrier prevents incorrect cable insertion - cable strand centering guides ensure correct cable positions and strand grouping v bistable din clip: simplifies disassembly v 63 to 125A: - up to 35mm 2 flexible with cable end - up to 50mm 2 stranded B curve Approval No:Q00542 utilisation when there are small inrush currents (generators, long cables). technical data v tripping curve: the magnetic trip units operate between 3 and 5 In. C curve Approval No:Q00542 utilisation cables feeding conventional loads. technical data v tripping curve: the magnetic trip units operate between 5 and 10 In. D curve - For industrial use only utilisation loads with a high inrush current (motors, transformers). technical data v tripping curve: the magnetic trip units operate between 10 and 14 In. Page 8 Schneider Electric Help Centre:
11 circuit-breakers up to 125 A C120H circuit-breakers 15kA, B, C curves - AS/NZS kA, D curve AS catalogue numbers type rating B C D (A) Curve Curve Curve C120H P Width in mod of 9mm - 3 2P Width in mod of 9mm P Width in mod of 9mm P Width in mod of 9mm - 12 Page 9
12 electrical auxiliaries for C60 and C120 circuit-breakers function They allow remote tripping or indication of circuit-breakers, with or without a Vigi module. description c they are mounted on the left-hand side of the circuit-breaker within a width limit of 54 mm c fixed using clips (without tools) on the left-hand side of the circuit-breaker c compatible with Vigi modules (adaptable on the right-hand side) c a maximum of 3 indication auxiliaries on the same circuit-breaker c a maximum of 2 OF+SD/OF auxiliary switches on the same circuit-breaker c a maximum of 2 MX+OF or MN tripping auxiliaries on the same circuit-breaker c a maximum of 1 MNs or MNx or MSU tripping auxiliary on the same circuit-breaker. auxiliary combination 54 mm max. 27 mm max. 36 mm max OF+SD/OF auxiliary contact OF auxiliary contact SD fault indicating switch MNs, MNx or MSU auxiliary MX + OF or MN auxiliary circuit-breaker Page 10 Schneider Electric Help Centre:
13 electrical auxiliaries for C60 and C120 circuit-breakers tripping Visualisation of tripping by means of the red indicator on front face. MX + OF shunt trip Remote tripping of a circuit-breaker: c equipped with an OF changeover switch: - to indicate the circuit-breaker s position - to carry out self-breaking allowing the control circuit to remain energized. Undervoltage releases (MN, MN s) Controls the tripping of a circuit-breaker when its supply voltage drops (threshold between 70 and 35 % of Un) It allows for manual closing of the circuit-breaker if its voltage exceeds 85 % of the rated voltage delayed MN s release 0.2 second time-delay: prevents tripping due to brownouts or momentary voltage decreases. MNx release for opening pushbutton Completely unaffected by power supply circuit cuts, it is recommended for fail-safe emergency stopping. Replaces the MX voluntary release equipped with its NO/NC indicator lights. MSU overvoltage MSU voltage threshold release Specially designed to monitor voltage between the neutral and phase(s) conductors, it cuts power supply by opening the circuit-breaker in event of an overvoltage. For overvoltages lasting for more than a few seconds. technical data Complance with standard: AS v release consumption type voltage power (V AC or DC) (W or VA) MX+OF 415 V AC inrush V AC inrush V AC inrush 200 DC inrush V AC inrush 22 DC inrush V AC inrush 120 DC inrush V AC inrush 20 DC inrush 20 MN V AC holding V AC holding 4.3 DC holding 2.0 MNs V AC holding 4.1 MNx 230 AC inrush AC inrush 120 MSU 230 AC inrush AC inrush 120 remote indication OF auxiliary switch v changeover switch that indicates the open or closed position of the circuit-breaker. v test button on the front face that allows for the indication circuit to be verified without operating the circuit-breaker SD fault indicating switch v changeover switch that indicates the fault trip position of the circuit-breaker v visualisation of the fault (SD) by means of a mechanical indicator on front face. OF+SD/OF selector switch v double changeover switch that indicates: v the open or closed position of the circuit-breaker (OF) v the fault trip position of the circuit-breaker (SD). v 2 circuits: - upper: OF - lower: SD or OF. v function is selected using rotary selector switch on the right-hand side v the selected function is indicated on the front face v visualisation of the fault (SD) by means of a red mechanical indicator on front face. technical data Complies with standard: AS v rated current of auxiliary contacts voltage rated current (V AC or DC) (A) 415 V AC V AC V DC 1 48 V DC 2 24 V DC 6 connection c using screw clamp terminals for 1 or 2 cables (max. 2.5 mm 2 ) c visible markers near terminals. Page 11
14 electrical auxiliaries for C60 and C120 circuit-breakers references type control voltage catalogue width (V AC) (V DC) number in mod. of 9 mm MX + OF shunt release U > C2 C MSU overvoltage release 1P + N U >> N L P + N U >> N L1 L2 L3 MN undervoltage release instantaneous U < D1 D2 delayed s MNx release for opening pushbutton Ph + N U < E1 E2 N L Ph to Ph U < E1 E2 L1 L2 Page 12 Schneider Electric Help Centre:
15 electrical auxiliaries for C60 and C120 circuit-breakers type control voltage catalogue width (V AC) (V DC) number in mod. of 9 mm SD fault indicating switch OF auxiliary contact OF+SD/OF selector switch Page 13
16 OF contact and SD switch, MX+OF, MN and MNs releases for C60 and C120 circuit-breakers shunt release MX + OF application c remote opening by circuit-breaker tripping, of electrical lighting circuits, etc connection c terminals 12 and 14 are used for indication of the circuit-breaker OF position, at a voltage identical to coil voltage U> c indication on the front face of the tripped function, by a red mechanical indicator C2 C1 closed open L or + N or - undervoltage release MN or MNs application c opening of electrical circuits by circuit-breaker tripping: v either by emergency stopping (mushroom head pushbutton) v or on mains failure connection U< c impossibility of uncontrolled restart is particularly recommended in two cases cases, thus guaranteeing complete safety: v when the machine operator is confronted with a risk of untimely restart: circular saw, rotating machine, etc v when it is necessary to control restart of an installation further to a mains failure c indication on the front face of the tripped function, by a red mechanical indicator c the MN coil is accepted as an emergency stopping device by the installation standard. However it does not indicate the OFF position of a circuit-breaker. D1 D2 Nor - L or + MNx release for emergency stopping on opening application c remote opening of the circuit by circuitbreaker tripping on a voluntary order: v emergency stop pushbutton on opening (fail-safe) v completely unaffected by network fluctuations. connection Ph/N U< E1 E2 N L - Nor L or + Ph/Ph U< E1 E2 L1 L2 L1 L2 L3 Page 14 Schneider Electric Help Centre:
17 OF contact and SD switch, MX+OF, MN and MNs releases for C60 and C120 circuit-breakers OF auxiliary contact application connection c audible or visual indication of circuit-breaker "open" or "closed" contact status v this indication can be transferred to the front face of a cubicle or enclosure or centralised on a control desk v optional contact testing using the knob on the front face, with the circuit-breaker open. circuit-breaker open closed OF contact position closed open 11 L or + N or - tripped SD fault indicating switch application c audible or visual indication of circuitbreaker tripped status: climatic room, lift, ventilation, etc connection c front face indication of contact status (red mechanical indicator) and of the "fault clearance" function v optional resetting of indication separately from the circuit-breaker v optional testing of contact on front face, with the circuit-breaker open. circuit-breaker open OF contact position fault normal 91 L or + N or - closed tripped OF + SD/OF changeover auxiliary switch application c double changeover switch: v the top switch indicates the "open" or "closed" status of the circuit-breaker v the bottom switch indicates according to user choice: - the "open" or "closed" status (OF) - the "tripped" status (SD) connection closed open L or + N or - c front face indication of the tripped status, by red mechanical indicator (regardless of lateral selector switch position) v optional testing of the bottom switch (SD changeover) on the front face, with the circuit-breaker open v optional resetting of indication separately from the circuit-breaker. circuit-breaker OF contact position open fault/ closed OF SD normal/ open L or + N or - closed tripped circuit-breaker SD switch position open closed tripped Page 15
18 Vigi modules for C60 and C120 circuit-breakers function Common function Adaptable toc60 & C120 circuit-breakers to 125 A - 2, 3, 4P, the Vigi up module ensures: c the protection of electrical installations against insulation faults c the protection of persons against indirect contact: medium sensitivities (300, 500mA) c additional protection of persons against direct contact: high sensitivity (30 ma) The C60/C120 residual current device complies with standard EN 61009: no heat derating of the circuit-breaker It is equipped with a locating device that ensures the correct rating and number of poles The technical data of circuit-breakers that are combined with Vigi modules remain unchanged and the circuit-breakers remain compatible with indication or control auxiliaries AC class Vigi module for which tripping is ensured by sinusoidal AC currents whether they are quickly applied or rise slowly Instantaneous It ensures instantaneous tripping (not time-delayed) Selective s Selective s Vigi modules allow for total vertical discrimination if: c upstream devices are s or delayed c downstream devices are instantaneous and their sensitivity is less than IDn/2 of the upstream device. description Technical data c the Vigi module incorporates the residual current relay and toroid in a case. Its earth leakage module is electromechanical. It functions without an auxiliary power supply source and thus has a very wide operating range c protected against nuisance tripping due to transient overvoltages (lightning stroke, switchgear switching on the network, etc.) c breaking and making capacity upon shortcircuit is equal to the breaking capacity of the circuit-breaker c instantaneous or selective s trip units c reinforced electromagnetic compatibility c remote tripping: possible using an MX or MN release on circuit-breaker c connection by tunnel terminals in mod. of 9mm c fault indication by means of a red strip on the resetting handle c resetting the Vigi module, at user s convenience: v either using the circuit-breaker handle v or independently of the circuit-breaker. c AC class: 50/60Hz c Minimum operating threshold for test button v Vigi C60 : 100VAC v Vigi C120 : 176VAC c AS3190, AS/NZS61009 (IEC61009) c Connection by tunnel terminals v Vigi C60 : up to 35mm2 stranded cables v Vigi C120 : up to 50mm2 stranded cables v Copper or aluminium cables (using aluminium cable terminal). type Vigi C60 Vigi C120 2P 4 7 3P P 7 10 combination of earth leakage modules with circuit-breakers = + C120 residual current device C120 circuit breaker Vigi C120 module Page 16 Schneider Electric Help Centre:
19 Vigi modules for C60 and C120 circuit-breakers catalogue numbers type voltage sens. catalogue number (V) (ma) Vigi C60 type AC ( 63A) 2P ma mA T 2 4 3P ma mA T P ma mA T type voltage sens. catalogue number (V) (ma) Vigi C120 type AC ( 125A) 2P T P T P T Page 17
20 accessories for C60 and C120 circuit-breakers catalogue numbers type suitable catalogue quantity for number per box padlocking C facility C C60 circuit-breaker Vigi C C120 circuit-breaker terminal shield C60 1P P P P terminal shield C120 1P P 2 x P 3 x P 4 x insulated sub terminal aluminium cable terminal Page 18 Schneider Electric Help Centre:
21 accessories for C60 and C120 circuit breakers type catalogue quantity number per box screw connection rear connection terminal with 1P terminal shield inter-pole barrier spacer marker strips marker strips label holder C120 replacement wire cover C60 2P P P Page 19
22 circuit-breakers up to 40A C32H-DC circuit-breakers AS functions description The C32H-DC circuit-breakers are designed for the protection and control of power circuits used in DC applications (eg; security lighting, automation, telephone systems) technical data common to C32H-DC circuit-breakers v voltage rating: single pole: 125V DC two pole: 250V DC v current ratings: 1 to 40 A set at 40 C v breaking capacity as in AS3947-2, Icu ultimate breaking capacity (O-CO operating cycle) type rating voltage breaking (A) (VDC) capacity Icu (ka) 1P 1 to 40 A P 1 to 40 A c tripping curve: type C the magnetic releases operate between 7 and 10 In. v number of operating cycles: (O-C) 10,000 at L/R sec v tropicalisation: treatment 2 (relative humidity 95% at 55 C) v connection: tunnel terminals for the following cables: - 16mm 2 flexible with cable end - 25mm 2 stranded c It is imperative to respect the polarity and function of the power supply. catalogue numbers type rating catalogue width quantity (A) number in mod per box of 9 mm C32H-DC single pole P Page 20 Schneider Electric Help Centre:
23 circuit breakers up to 40A C32H-DC circuit-breakers for DC applications selecting the circuit-breaker The selection of a circuit-breaker most suitable for protection of a DC installation, depends mainly on the following criteria: c the nominal current, which determines the rating of the equipment c the type of network c the nominal voltage, which determines the number of poles to be involved in breaking c the maximum short-circuit current at the point of installation, which determines the breaking capacity calculation of the short-circuit current (Isc) at the terminal of a battery When a short-circuit occurs at its terminals, a battery discharges a current given by Ohm s law: Isc = Vb Ri where Vb = the maximum discharge voltage (battery 100 % charged) and Ri = the internal resistance equivalent to the sum of the cell resistances (figure generally given by the manufacturer in terms of Ampere-hour capacity of the battery). example What is the short-circuit current at the terminals of standing battery with the following characteristics: c capacity: 500 Ah c maximum discharge voltage: 240 V (110 cells of 2.2 V) c discharge current: 300 A c internal resistance: 0.5 mω per cell Ri = 110 x 0.5 x Isc ISC = 55 x 10 3 Isc ISC = 4.4 ka As the above calculation shows, the short-circuit current is relatively weak. Note: if the internal resistance is not known, the following aproximate formula can be used: Isc = kc, where C is capacity of the battery expressed in Ampere-hours, and k is a coefficient close to 10 but in any case always lower than 20. Page 21
24 circuit breakers up to 40A C32H-DC circuit-breakers for DC applications recommendations for use connection diagram The C32H-DC special DC circuit-breaker is designed for the control and protection of circuits up to 250 V DC with Isc 20 ka. For higher voltages or short-circuit currents, refer to the previous pages. The circuit-breaker connection diagram to be used depends on the service voltage, the Isc of the installation and the position of the load: C32H-DC 1 pole c service voltage 125 V DC c Isc 10 ka C32H-DC 2 poles c service voltage 250 V DC c Isc 10 ka load load load + C32H-DC 2 poles c service voltage 125 V DC c Isc 20 ka load load Note : The C32H-DC is a polarized circuit-breaker, equipped with a permanent magnet for satisfactory breaking of the rated current. In accordance with the diagram to be used, always respect the + and - polarities indicated on the circuit-breaker. Page 22 Schneider Electric Help Centre:
25 Tm motor mechanism for C60N/H and C120N/H circuit breakers function Tm motor mechanism is used for: c the remote control of C60/C120 circuit-breakers (with or without a Vigi module) via a latched order, c circuit-breaker resetting after tripping. Local control using the operating handle continues to be possible, as is adaptation of other circuit-breaker auxiliaries. description OF+SD/OF auxiliary switch OF auxiliary contact SD fault indicating switch MNs,MNx or MSU auxiliary MX + OF or MN auxiliary Tm remote control circuit-breaker c Tm modules are controlled by an electrical latched type order. c a disconnection selector switch placed on the front panel is used to: v neutralise the remote control v lock the remote controlled circuit-breaker in the "open" position (7 mm Ø padlock not supplied). c a mechanical indicator shows the "open" or "closed" status of the Tm remote control. c reclosing after a fault: v must be carried out in manual mode, locally after search and clearance of the fault v to impose manual and local resetting, an SD auxiliary switch (ref ), cabled in series in the Tm module, prevents automatic and remote reclosing v remote reclosing is possible provided regulations are complied with: resetting takes place by opening the control circuit for more than 1.5 s. c auxiliaries in the C60/C120 range, adaptable to circuit-breakers using clips (without tools), v instantaneous or delayed undervoltage tripping: MN and MNs v instantaneous shunt tripping: MX+OF v fault trip indication: SD v indication of the circuit-breaker's open or closed position: OF. c other possible control modes:v control by an impulse and/or latched order: ACTc v time-delayed: ACTt v by BatiBUS network: ATB1s. technical data c control voltage (Uc): 230 V AC (-15 % +10 %) c frequency: Hz c consumption: v inrush: - TmC60: 28 VA - TmC120: 35 VA v holding: 2 VA c insensitive to brownouts: 0.45 s c undervoltage behaviour: v > 0.45 s, mechanical opening of poles v reclosing 2 s after power is restored. c number of cylcles (O-C) at 40 C: v Tm + C60: v Tm + C120 ( 63 A): v Tm + C120 ( A): c opening time by Tm: 0.5 s c closing time by Tm: 2 s connection c using tunnel terminals: v 1 x 6 mm 2 cable v 2 x 1.5 mm 2 or 2.5 mm 2 cables. weight c 1-2P: 300 g c 3-4P: 310 g. Page 23
26 Tm motor mechanism for C60N/H and C120N/H circuit breakers catalogue numbers type voltage catalogue width quantity (v AC) number in mod. per box of 9 mm C60 1-2P C P A1 MX MN SD OF auto 230 V A2 C60 3-4P C P A1 MX MN SD OF auto 230 V A2 Page 24 Schneider Electric Help Centre:
27 Dimensions C60a/N/H circuit breakers Vigi C60 C120N/H circuit breakers Vigi C P 108 3P P P P OFF OFF OFF OFF Ø3 max Ø7 max 95 OFF OFF OFF OFF P 2P 3P 4P C60/C120 auxiliaries OF+SD/ OF OF, SD OF, S MX MN MN s OF+SD/OF C60 accessories C120 accessories OFF 81 OFF OFF OFF OFF 81 OFF OFF Page 25
28 Dimensions C32H-DC circuit breakers C32H-DC auxiliaries 1P 2P MN MX MO OF SD Tm C60/C120 1P, 2P 3P, 4P Page 26 Schneider Electric Help Centre:
29 Locations Head Office: 2 Solent Circuit, Norwest Business Park, Baulkham Hills NSW 2153 Tel: (02) Sales Offices: NSW 2 Solent Circuit, Norwest Business Park, Baulkham Hills NSW 2153 Tel: (02) Fax: (02) VIC 77 Ricketts Road, Mt Waverley VIC 3149 Tel: (03) Fax: (03) SA Building 1A, Corbett Court, Export Park, Adelaide Airport SA 5950 Tel: (08) Fax: (08) WA 26 Gibberd Road, Balcatta WA 6021 Tel: (08) Fax: (08) QLD 30 Graystone Street, Tingalpa QLD 4173 Tel: (07) Fax: (07) Regional Offices: Albury - Tel: Fax: (02) Newcastle - Tel: (02) Fax: (02) Ballarat - Tel: Fax: (03) Orange - Tel: (02) Fax: (02) Cairns - Tel: Fax: (07) Rockhampton - Tel: Fax: (07) Darwin - Tel: Fax: (08) Wollongong - Tel: Fax: (02) Manufacturing Facilities MV Transformers & Substations Sydney Road, Benalla VIC Tel: (03) Fax: (03) MV Switchgear 77 Ricketts Road, Mt Waverley VIC Tel: (03) Fax: (03)
30 HELP CENTRE Tel: Fax: AUS Schneider Electric (Australia) Pty Limited Postal Address: Locked bag 5500 Baulkham Hills Business Centre NSW 2153 Australia Tel: +61 (2) As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. Publishing: Schneider Electric Design, production: The Graphic Shop Photos: Schneider Electric Printing: TBA
Electrical auxiliaries 0 For i DPN (DPN), C60 and C120
Circuit protection For i DPN (DPN), C60 and C120 Function They remotely trip or indicate circuit-breakers, with or without Vigi module. Description b They are mounted to the left of the circuit-breaker
Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Breaking and protection devices
Breaking and protection devices 05 POWER GUIDE 2009 / BOOK 05 INTRO The purpose of selecting a protection device is to perform two essential functions: to protect people and to protect trunking, while
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Emergency lighting units EM powerled
M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Wiring diagrams. Compact NSX. Contents
Compact NSX Wiring diagrams Contents Functions and characteristics A-1 nstallation recommendations B-1 Dimensions and connection C-1 Compact NSX100 to 630 Fixed circuit breakers D-2 Plug-in / withdrawable
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
Circuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
Sentron Series Circuit Breakers
Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of
5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.
The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
Submit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A
Low voltage electrical distribution Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A User manual 09/2009 User manual for circuit breakers and switch-disconnectors Masterpact
The complete range of consumer switchboards and switchgear
Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Manual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M
ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M Tested, certified, reliable Network monitoring and protection The electronic residual current
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Data Sheet. Electro-mechanical counters Hengstler 800 series
Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from
more than a breaker it s a breakthrough Compact NSX
Compact NSX, more than a breaker it s a breakthrough Compact NSX 100-630 A Intelligent outlook Today, we are living in an increasingly booming and fast changing world where energy is key. More than ever,
Electrical safety and protection devices
Electrical safety and protection devices RCD PROTECTION The easy, economical way to safeguard yourself when working with electricity. RCDs are specifically designed to minimise the risk of a fatal electric
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.
ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. Ensuring operational continuity To ensure the operational continuity of an electrical
Contact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Current and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
instabus KNX / EIB System System E F G H
Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA
Fundamentals of Power
Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
Motor circuit-breakers
Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
RCA Remote Control ic60 Circuit Breakers Reference Manual
9M01EN 01/2011 RC Remote Control ic60 Circuit reakers Reference Manual 01/2011 9M01EN www.schneider-electric.com The information provided in this documentation contains general descriptions and/or technical
Contact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
T 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Tmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
Molded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet
Instruction Bulletin 63230-216-244B1 LaVergne, TN, USA MCS025 Sync-Check Module Installation Sheet Retain for future use. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Only qualified electrical
Manual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution
UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52
Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
mecotron Safety relay ESTOP-2 For emergency stop monitoring
E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated
12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS
LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS Terence Hazel Senior Member IEEE Schneider Electric 38050 Grenoble France Abstract The power requirements for large industrial sites is increasing.
Specification guide no. 9 Active harmonic conditioner from 20 to 480 A
Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable
E-STOP relays, safety gate monitors
Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World
Catalogue 2002 Automatic capacitor banks Building a New Electric World 0Contents Power factor correction 2 Power factor equipment selection guide 3 General technical data 4 Capacitors and banks 50 z 6
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy
Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Siemens Protection Devices Limited 2 7PG17 XR101 & XR102 Intertripping Relay
The standards mentioned in this document
The standards mentioned in this document Where can you order IEC publications? Central Offices of the International Electrotechnical Commission 1, rue de Varembé Geneva - Switzerland. The documentation
SKR - industry relay
SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
Bimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
Technical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
PNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input