NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution
|
|
|
- Grant Dalton
- 9 years ago
- Views:
Transcription
1 NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION Super Solution
2 Low voltage circuit breakers Susol LV circuit breakers Super Solution
3 Contents Overview Electrical characteristics Trip units Accessories Technical information Characteristics curves Overall dimensions Design for technical strong point: The Susol MCCB SuSol Series MCCB is available forworld best breaking capacity up to 150kA, and MS is seal structure for hidden electricity Arc. SuSol product represents simultaneously simple and complicated design for using cut diamond motive to emphasis on the hardness of industrial product. And we applied the identity of product image by designing same concept MCCB and MS which is installed to cubicle. SuSol Series acquire the competitive power through getting the picking up GD product and wining IF Design Award. >>>
4 Super solution Super Performance Super Breaking capacity Super Optimum coordination Super Extensive applications
5 TE series New member of Susol MCCBs New borning of 160AF The fifth frame TE100, TE160 Small, but Big benifit More compact and less cost TE100 In : 16~100A (fixed ) Icu : 37kA(S), 50kA(N), Ics=Icu 3 and 4 pole 76(W) x 130(H) x 82mm(D) TE160 In : 100~160A (fixed or thermally adjustable) Icu : 37kA(S), 50kA(N), Ics=Icu 3 and 4 pole 76(W) x 130(H) x 82mm(D)
6 MCCB Susol TD, TS, TE circuit breakers are rated from 16 to 800 amperes and are available in four frame sizes. Ics=100% Icu : 37, 50, 65, 85, 100, 150kA at 415VAC 100kA 65kA 150kA 100kA 85kA 65kA 50kA 37kA TS800L TS630L TS400L TS250L TS800H TS630H TS400H TS250H TS800N TS630N TS400N TS250N Rated current, In (A) TE100/160 In 16~160A Icu : 37kA(S), 50kA(N) Ics=Icu 76(W) x 130(H) x 82mm(D) TS160L TD160L TS100L TD100L 150kA TS160H TD160H TS100H TD100H 85kA TS160N TD160N TS100N TD100N 50kA TE160S TE100S 37kA Breaking capacity Icu at 380 / 415V (ka) TE160N TE100N 800A 630A 400A 250A 160A 100A
7 Super Performance TD100/160 In 16~160A Icu : 50kA(N), 85kA(H), 150kA(L) Ics=Icu 90(W) x 140(H) x 86mm(D) 28 models in 5 frames TS100/160/250 In 40~250A Icu: 50kA(N), 85kA(H), 150kA(L) Ics=Icu 105(W) x 160(H) x 86mm(D) TS400/630 In 300~630A Icu: 65kA(N), 85kA(H), 150kA(L) Ics=Icu 140(W) x 260(H) x 110mm(D) TS800 In 700, 800A Icu: 65kA(N), 100kA(H), 150kA(L) Ics=Icu 210(W) x 320(H) x 135mm(D)
8 MCCB Flexibility through modularity Susol series offer various and compatible accessories which are providing simple installation and easy upgrading of the circuit breaker. Harmonization of the accessories allows stock reduction and greater service flexibility.
9 System overview Circuit breaker Insulation barrier Terminal cover(short, long) Connection terminals Direct rotary handle Extended rotary handle Electrical auxiliaries Mechanicla interlock device
10 Electrical characteristics Frame size [AF] Rated current In [A] No. of poles Rated operational AC [V] voltage, Ue DC [V] Rated impulse withstand voltage, Ui [V] Rated ultimate short-circuit breaking capacity, Icu AC 50/60Hz 220/240V [ka] 380/415V [ka] 440/460V [ka] 480/500V [ka] 600/690V [ka] DC 250V [ka] DC(2poles in series) 500V [ka] Rated service breaking capacity, Ics [%Icu] Rated ultimate short-circuit making capacity, Icm AC 50/60Hz 220/240V [ka] 380/415V [ka] 440/460V [ka] 480/500V [ka] 600/690V [ka] Category of utilization Isolation behavior Trip unit(release) Thermal magnetic fixed-thermal, fixed-magnetic FTU adjustable-thermal, fixed-magnetic FMU adjustable-thermal, adjustable-magnetic ATU magnetic only MTU Electronic LSI ETS LSI ETM Option Earth-fault protection, lg Zone selective interlocking, 'ZSI Ammeter Communication Earth-leakage protection module Connection Fixed front-connection rear-connection Plug-in front-connection rear-connection Mechanical Life [operations] Electrical 415V AC [operations] Basic dimensions, WxHxD 3-pole [mm] (front connection) 4-pole [mm] Weight 3-pole [kg] (front connection) 4-pole [kg] Reference standard TE100 TE ~ ,125,160 3,4 3, S N S N % 100% 100% 100% A A x130x82 76x130x82 101x130x82 101x130x IEC IEC
11 Trip units Thermal magnetic trip units Overview Characteristics Fixed thermal, fixed magnetic trip units FTU Fixed thermal 16A A rated currents Fixed magnetic 400A A tripping currents TE160 FTU Ir Im Im=1600A 160A Adjustable thermal, fixed magnetic trip units FMU Adjustable thermal 16A A rated currents Adjustable : 0.8~1 In Fixed magnetic 400A A tripping currents TE160 FMU Im=1600A 160A Setting details In Neutral protection TE160 Thermal setting Ir[A] Magnetic setting Im[A] [A] 4P4T 4P3T =Ir =Im =Ir =Im ±20% =Ir =Im =Ir =Im =Ir =Im FTU 50 Ir = In =Ir =Im no protection =Ir =Im =Ir =Im 10xIn ±20% =Ir =Im =Ir =Im =Ir =Im =Ir =Im =Ir =Im ±20% =Ir =Im =Ir =Im =Ir =Im FMU 50 Ir = 0.8-1In =Ir =Im no protection =Ir =Im =Ir =Im 10xIn ±20% =Ir =Im =Ir =Im =Ir =Im 11
12 Accessories Auxiliary and Alarm switch Auxiliary switch (AX) Auxiliary switch is for applications requiring remote ON and OFF indication. Each switch contains two contacts having a common connection. One is open and the other closed when the circuit breaker is open, and viceversa. Alarm switch (AL) Alarm switches offer provisions for immediate audio or visual indication of a tripped breaker due to overload, short circuit, shunt trip, or undervoltage release conditions. They are particularly useful in automated plants where operators must be signaled about changes in the electrical distribution system. This switch features a closed contact when the circuit breaker is tripped automatically. In other words, this switch does not function when the breaker is operated manually. Its contact is open when the circuit breaker is reset. Combination switch (AX+AL) It consists of one auxiliary switch (AX) and one alarm switch (AL) in a body to connect into the same position of the breaker. Contact MCCB ON OFF TRIP AX AL Conventional thermal current, Ith 5A Rated operational current, Ie Rating AC 50/60Hz DC Voltage, Ue 125V 250V 500V 30V 125V 250V Current, Ie Resistive load Inductive load
13 Accessories Shunt trip, SHT The shunt trip opens the mechanism in response to an externally applied voltage signal. The releases include coil clearing contacts that automatically clear the signal circuit when the mechanism has tripped. The shunt release can be installed in the right accessory compartment of the MCCBs. - Range of operational voltage AC : 0.7~1.1Vn, DC : 0.8~1.1Vn - Frequency(Only AC) : 45Hz ~ 65 Hz Rating Control voltage, Ue AC (VA) Power consumption DC (W) ma AC/DC 12V AC/DC 24V AC/DC 48V Voltage AC/DC 60V AC/DC 100~130V AC/DC 200~250V AC 380~450V AC 440~500V Max.opening time 50ms (max.) Tightening torque of terminal screw 8.2 kgf cm 13
14 Accessories Undervoltage release, UVT The undervoltage release automatically opens a circuit breaker when voltage drops to a value ranging between 20% to 70% of the line voltage. The operation is instantaneous, and after tripping, the circuit breaker cannot be re-closed again until the voltage returns to 85% of line voltage. Continuously energized, the undervoltage release must be operating before the circuit breaker can be closed. The undervoltage release can be easily installed in the right accessory compartment of the MCCBs. - Range of tripping voltage: 0.2 ~ 0.7Vn - MCCB making is possible voltage: 0.85Vn (Exceed) - Frequency (Only AC): 45Hz ~ 65Hz Rating Control voltage, Ue AC (VA) Power consumption DC (W) ma AC/DC 24V AC/DC 48V AC/DC 100~110V Voltage AC/DC 200~220V AC 380~440V AC 440~480V Max.opening time 50ms (max.) Tightening torque of terminal screw 8.2 kgf cm Operating Trip 20~70% Vn voltage range Reset/Closing 0.85Vn Maximum possibilities TE160 Position Type 3/4P AX 1 Left-hand seat AL 1 AX 1 Right-hand seat AL 1 SHT/UVT 1 Note) Rigth-hand seat can be installed only one Electrical Accessary 14
15 Accessories Rotary handles The rotary handle operating mechanism is available in either the direct version or in the extended version on the compartment door. It is always fitted with a compartment door lock and on a request it can be supplied with a key lock in the open position. Direct rotary handles MCCB TE160 Rotary handle DH1E Extended rotary handles MCCB TE160 Rotary handle EH1E Degree of protections Type Degree of protection IP DH1E EH1E The acess probe of 1.0mm diameter shall not penetrate Totally protected against ingress of dust and water jets from any direction IP40 IP55 15
16 Accessories Terminals Front connection Extended terminal - As an optional part of circuit breaker - Can increase the pitch of the terminals MCCB Pole Type Feature TE100 3P ET13E TE160 4P ET14E Rear connection Rear connection terminals are used to adapt Susol TE circuit breakers to switchboards or other application that require rear connection. These can be connected directly to circuit breakers without any modification. Flat terminals MCCB Pole Type Feature TE100 3P RTF13 TE160 4P RTF14 16
17 Accessories Insulation Insulation by barrier These allow the insulation characteristics between the phases at the connections to be increased. They are mounted from the front, even with the circuit-breaker already installed, inserting them into the corresponding slots. They are incompatible with both the insulating terminal covers. It is possible to mount the phase separating partitions between two circuit-breakers side by side. Type Applied MCCB Set quantity B13C TE100, TE160 3P 2pcs 4P 4pcs Insulation by terminal cover Insulation terminal cover The terminal covers are applied to the circuit-breaker to prevent accidental contact with live parts and thereby guarantee protection against direct contacts. Short type covers Two types by length are available: Short type covers, ITS IP40 degree of protection For fixed circuit-breakers with rear terminals and for moving parts of plug-in Long type covers, ITL IP40 degree of protection For fixed circuit-breakers with front, front extended, front for cables terminals. Type Terminal cover Frame type pole Long type Short type Long type covers TE100, TE160 3P ITL13E ITS13E 4P ITL14E ITS14E 17
18 Accessories Interlock Mechanical interlocking device The mechanical interlock (MIT) can be applied on the front of two breakers mounted side by side, in either the 3-pole or 4-pole version and prevents simultaneous closing of the two breakers. Fixing is carried out directly on the cover of the breakers. The front interlocking plate allows installation of a padlock in order to fix the position. (possibility of locking in the O-O position as well) Mechanical Interlock (Padlocks are not supplied) This mechanical interlocking device is very useful and simple for consisting of manual source-changeover system. MCCB Interlock Frame type pole Operation TE100, TE160 3P 4P MIT13E MIT14E Left MCCB: ON/OFF is possible Right MCCB: Off lock Interlock handle Interlock bar Left MCCB: Off lock Right MCCB: ON/OFF is possible Both MCCBs are of locked Note) Terminal covers do not use with the interlock. 18
19 Technical information Power dissipation / Resistance Susol TE series MCCB with thermal-magnetic trip units AF TE100 TE160 Rationg (A) R (MΪ ) Fixed MCCB Watt single pole Watt three pole
20 Characteristics curves Thermal-Magnetic trip units TE100 FTU FMU 16~100A 20
21 Characteristics curves Circuit breakers with thermal-magnetic trip units TE160 FTU FMU 100~160A 21
22 Overall dimensions TE100/TE [mm] C L C L Wire size Min 2.5mm 2 Max. 70mm 2 L L L(mm) 17.5 T W W(mm) 13.5 T(mm) 6 Torque 8Nm Panel drilling Front panel cutting C L M4 OR 5 C L C L C L C L 110 C L 110 C L C L
23 Overall dimensions Direct rotary handle DH1E for TE100/TE160 OFF 4-5 t 1.2~
24 Overall dimensions Extended rotary handle EH1E for TE100/TE160 OFF t 1.2~3.2 min 165 max 589(shaft 459mm)
25 Overall dimensions Mechanical interlocking device MIT13E, MIT14E 82 4~ mm E D E C C 25
26 Overall dimensions Terminal cover ITS13E, ITS14E ITL13E, ITL14E
27 7 Overall dimensions Rear connection RTF13, RTF N m (82kgf cm) 8N m (82kgf cm) 27
28 Overall dimensions Extended terminal ET13E, ET14E N m (82kgf cm) N m (82kgf cm) 16Max 5Max 28
29 Memo 29
30 Memo 30
31 Memo 31
32 Super Solution HEAD OFFICE LS Tower , Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do , Korea Tel. (82-2) , 4873, 4918, 4148 Fax. (82-2) Cheong-Ju Plant Cheong-Ju Plant #1, Song Jung Dong, Hung Duk Ku, Cheong Ju, , Korea Tel. (82-43) Fax. (82-43) Specifications in this catalog are subject to change without notice due to continuous products development and improvement / STAFF c LS Industrial Systems Co.,Ltd. All rights reserved.
Tmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
General information Circuit breakers for power distribution T1 T3
Circuit breakers for power distribution T1 T3 T1 T2 T3 T1 1P T1 T2 T3 UL 489 CSA C22.2 Frame size A 100 100 100 225 Number of poles Nr 1 3, 4 3, 4 3, 4 Rated voltage AC (50-60 Hz) V 277 600Y / 347V 480
Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
Breaking and protection devices
Breaking and protection devices 05 POWER GUIDE 2009 / BOOK 05 INTRO The purpose of selecting a protection device is to perform two essential functions: to protect people and to protect trunking, while
SENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.
The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved
Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A
Low voltage electrical distribution Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A User manual 09/2009 User manual for circuit breakers and switch-disconnectors Masterpact
Circuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Molded case circuit breakers
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high
Type: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
more than a breaker it s a breakthrough Compact NSX
Compact NSX, more than a breaker it s a breakthrough Compact NSX 100-630 A Intelligent outlook Today, we are living in an increasingly booming and fast changing world where energy is key. More than ever,
Technical catalogue - Ordering Codes. SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated
Technical catalogue - Ordering Codes SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated New SACE Tmax XT. Simply XTraordinary. Today a highly advanced range of circuit-breakers
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
Type: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
Motor circuit-breakers
Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors
Low Voltage. EasyPact CVS. Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A. Catalogue 2011
Low Voltage EasyPact CVS Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A Catalogue 2011 Safe Reliable Simple The easy choice for quality and value EasyPact CVS LV circuit breakers
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Spare parts Catalogue
Technical catalogue Spare parts Catalogue Low voltage circuit-breakers Product support ABB SACE SDC0000D00 Not every original spare parts are really original spare parts. Availability of spare parts for
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
Data Bulletin. Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers. Introduction. Thermal-Magnetic or Electronic Trip Unit?
Data Bulletin 011DB110 07/01 Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers ENGLISH Inoduction Thermal-Magnetic or Eleconic Trip Unit? Thermal-Magnetic Trip Units 01171 t 0119
Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data
Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors Technical Data Table of Contents Introduction... 4 Definitions... 5 Product Range... 8 Product Line Overview...11
Emax DC. Annex to the technical catalogue. Low voltage Switch-disconnectors and Automatic circuit-breakers for Direct Current Applications
Annex to the technical catalogue Emax DC Low voltage Switch-disconnectors and Automatic circuit-breakers for Direct Current Applications 1SDC200012D0201 Index SACE Emax DC automatic circuit-breakers...
Sentron Series Circuit Breakers
Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution
Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is
IZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors
IZM ACB/Circuit-breakers Robust safety Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors t [s] 0.1 0.05 0.04 0.03 0.02 0.01 20 1230DIA-125 (70C1043) 30 40 50 60 80 100
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
The complete range of consumer switchboards and switchgear
Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial
ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
Current and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
Safety detection solutions
Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking
Applications. diris_826_a_1_gb_cat
Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered
8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
Molded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
P System Cubicles. Certified for more safety
P System Cubicles Prisma Plus LV Switchboards Certified for more safety Prisma Plus, an offer thought out for greater professionalism With the Prisma Plus P system, Schneider Electric proposes high-performance
The following components are common to most cubicles; this example is an ABB HK cubicle.
4.0 CIRCUIT BREAKER CUBICLE Learning Objectives The circuit breaker cubicle is the component of the switchgear that holds the circuit breaker, and the controls and cabling for the distribution system.
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Low Voltage Products. Switches Automatic Transfer Switches
Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold 41-759.3C
41-759.3C the magnetic core upon energizing of the switch. When the switch closes, the moving contacts bridge two stationary contacts, completing the trip circuit. Also during this operation two fingers
NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD
Shanghai Liangxin Electrical CO.,LTD Address: No. 668 Heng An Road, Pu Dong New District, Shanghai Zip: 200137 Tel: 86-21-5012789 Fax: 86-21-58675966 E-mail: [email protected] LINE 1 LINE 3 LINE 5
Bimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
Manual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
Technical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
Manual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
Tmax. Molded case circuit breakers. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]. Tmax.
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
PSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet
Instruction Bulletin 63230-216-244B1 LaVergne, TN, USA MCS025 Sync-Check Module Installation Sheet Retain for future use. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Only qualified electrical
Catalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
GE Energy Industrial Solutions. Record SL Moulded Case Circuit Breakers Standard Line
GE Energy Industrial Solutions Record SL Moulded Case Circuit Breakers Standard Line GE GE is a diversified organization covering a myriad of market segments, including infrastructure, finance and media.
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
RY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Catalog. Arc Guard System TM TVOC-2
Catalog Arc Guard System TM TVOC-2 Introduction An even better Arc Guard System TVOC-2, ABB s latest Arc Monitor, builds on the well known TVOC design. Its new functions and features improve an already
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
SKR - industry relay
SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,
CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS
CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS David D. Roybal, P.E. Senior Member, IEEE Eaton Electrical 3697 Mount Diablo Boulevard Lafayette, CA 94549 Abstract Low-voltage circuit
D.C. Motors. Products and specifications subject to change without notice.
D.C. Motors Order/Technical Support - Tel: (8) 677-5 / FAX: (8) 677-865 / www.crouzet-usa.com / DC Motors Selection guide Gearbox Speed Torque max (Nm).5. Type of Gearbox 8 8 8. Power usable (w) Torque
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
The Intelligent AX1 Switchgear for Medium Voltage
The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)
9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity
A sophisticated design for a demanding field. prima series
A sophisticated design for a demanding field prima series 2 nd edition 2003 prima compact horizontal interlocked sockets carefully studied A size for all versions with or without fuses. Extends horizontally
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
White paper. ABB solutions for switching and protection of low speed wind turbines
White paper ABB solutions for switching and protection of low speed wind turbines ABB solutions for switching and protection of low speed wind turbines Index 1 Introduction...2 2 Full converter configuration...4
Speed Control Relays SX2
SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
FUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue 2011-2012 SOCOMEC. Fuse combination switches
FUSERBLOC Fuse combination switches appli_8_a fuser_548_a cat fuser_59_a cat fuser_52_a cat 2 to 25 A Manual operation Function FUSERBLOC are manually operated multipolar fuse combination switches. They
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
Vario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.