Emergency Light Fittings



Similar documents
Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

7 Lighting Technology

Product and functional description

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W

e explosion-proof emergency light fittings battery sets for zone 1/21 and zone 2/22 e 187/ nd 187/188...

HERZ-Thermal Actuators

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Emergency lighting units EM powerled

Thyristor-controlled power supplies and battery chargers

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

H45 LED - Direct and indirect pendant

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Vario-Series Accessories

6 LED colours: White Blue Green Red Yellow Amber

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Wolflite Safety Handlamp H-251E

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Electric Rotary Actuator - On/Off or programmable control actuator

morelux QUALITY HIGH & LOW BAY LIGHTING CATALOGUE 2003/04

Mureva Assembly surface mounted wiring devices

Emergency Lighting Introduction

Cable Plug acc. to DIN EN , Form A

Assisted lift operated 2/2-way solenoid valves Type EV250B

Nightscape High performance floodlights and spotlights for discharge lamps

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

2013 Wireless Video Intercom INSTALLATION GUIDE

Features. High Brightness LED Light source

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Terminal Boxes Series 8146

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

FIREDEX Conventional Fire Panels

Industrial plastic LED light fittings Industrial metal LED light fittings Emergency LED light fittings

Digital inductive conductivity transmitter

LED MACHINE ILLUMINATIONS

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

13 SERIES. Electronic step relays A

How To Read A Pipe From A Sensor

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

RESOLUX / HIGHLITE/ COMPACT LINE Technology Lighting as its best. Designed and produced in Germany

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Lumolux S CHARACTERISTICS / ADVANTAGE. System of protection. 524 mm mm. G = Borosilicate glass. 2 x 8 W - 58 W

LED control gear. LED control gear

Morgue refrigeration unit

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Series 8146/5-V37 and Series 8150/5-V37

High protection factor luminaires

RY2 miniature industrial relays

Nightspot A2 Floodlights for LEDs and high pressure discharge lamps

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

ALARMLINE ANALOGUE Linear Heat Detection System

Digital Keypad Use s Manual

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

System Manual 1+n technology Issue 2013

Floodlight Range Installation Guide

LED High Bay Light 100W

Medical Lighting. XL4 Patient Light

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

LED HIGHBAY COMMERCIAL & INDUSTRIAL DESIGNED MANUFACTURED AND WARRANTED IN AUSTRALIA

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

Solenoid Valve Island Type 3965

Single sub-base valve

Contents. Additional Hella Products White Noise Back-up Alarms Switches Camera Systems. Technical Data Hella Test Standards IP Ratings

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Thermal-Magnetic Circuit Breaker M1-..

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

HP UPS R1500 Generation 3

DALI RC BASIC SO. Control unit Operating instructions

Photovoltaic Solar Energy Unit EESFB

Nightspot High performance floodlights for discharge lamps and LEDs

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

ABB i-bus KNX SA/S Switch Actuators Product Manual

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

Cross-beam scanning system to detect slim objects. 100 mm in

Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Fluxa Area floodlights for high pressure discharge lamps and LEDs

FACT SHEET 90 mm premium LED modules Mono and Bi-LED module with low and high beam

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Transcription:

Emergency Light Fittings

SCHUCH Emergency Light Fittings NEW NEU 164 218/25.. Dustproof/waterproof emergency light fitting for wind power stations. Description Series Page Polyester with Diffuser Insulation class II Insulation class I Polyester without Diffuser Insulation class II NEW NEU 131 208/... Small shock resistant emergency light fitting for wind power stations. Emergency Light Fittings for Wind Power Stations Insulation class I Emergency Light Power Supply Unit Emergency Light Fitting

Dustproof/Waterproof Polyester Emergency Light Fittings of Insulation Class II Series 161/162... For illumination of working places and acc. to DIN VDE 0108 for illuminating and identifying escape routes etc. Mechanical Data: Housing: Glass fibre reinforced polyester resin, polyurethane gasket. Diffuser: Injected clear acrylic glass or polycarbonate (PC) each with internal prisms. Closure: External plastic clips (KK). Stainless steel clips (KE) available upon request and at extra charge. Reflector: Glass fibre reinforced polyester resin, that can be suspended or removed. It carries the electrical components which are protected against accidental contact. Connection: 3-pole plug-in terminal. Cable entry: 2 plugs M20 x 1,5. Looping the cable at one small end of the housing upon request and at extra charge. Through wiring system: Up to 5x2,5mm 2 (extra charge). Mounting system: Closed knock-outs for direct ceiling mounting, rubber sealing washers inside each fitting. Wiring diagram 161... maintained operation light switch Wiring diagram 162... maintained operation Electrical Data: (series 161/162... only) Incorporated NiCd battery set which is constantly charged and therefore ready for operation any time. Visual monitoring the battery charging process through LED. Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN 60598-2-22. Luminous flux raising i.e. initially the emergency lamp has got a higher luminous flux. Modes of functioning: Maintained operation = in case of mains failure 1 lamp is switched over to battery operation. In the 2-lamp version (type 162...) only one lamp will be operating as emergency lighting. Connection voltage: 230V, 50Hz (standard) Ambient temperatures convent. ballast: -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) Ambient temperatures (EVG): -5 C up to +40 C (maintained version) light switch Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1' Shock resistance test: RK 1,6 / 16A 161/162... with battery set T 26 161 158... 162 258... T 38 Type Article no. Lamps/ Flux factor Weight Watts approx. % approx. kg 1 hour emergency operation, with conventional ballasts IP65 161 136/34/1 16110 0025 1 x T 26/36 W 34 4,4 161 136/18/1 5) 16110 0009 1 x T 26/36 W 18 4,1 161 158/22/1 16110 0026 1 x T 26/58 W 22 4,9 161 158/15/1 5) 16110 0010 1 x T 26/58 W 15 4,6 162 218/65/1 16210 0083 2 x T 26/18 W 65 3,7 162 218/38/1 5) 6) 16210 0076 2 x T 26/18 W 38 3,3 162 236/34/1 16210 0084 2 x T 26/36 W 34 5,6 162 236/50/1 16210 0085 2 x T 26/36 W 50 7,7 162 236/18/1 5) 6) 16210 0051 2 x T 26/36 W 18 5,3 162 258/22/1 16210 0086 2 x T 26/58 W 22 7,5 162 258/31/1 16210 0087 2 x T 26/58 W 31 7,7 162 258/15/1 5) 6) 16210 0054 2 x T 26/58 W 15 7,2 Series 161... Series 162... 1 hour emergency operation, with electronic ballast (EVG) 161 136/34/1 EVG 16110 0027 1 x T 26/36 W 34 3,8 161 136/18/1 EVG 4) 5) 16110 0017 1 x T 26/36 W 18 3,5 161 158/22/1 EVG 16110 0028 1 x T 26/58 W 22 4,2 161 158/15/1 EVG 4) 5) 16110 0018 1 x T 26/58 W 15 3,9 162 218/65/1 EVG 16210 0082 2 x T 26/18 W 65 3,3 162 218/38/1 EVG 4) 5) 6) 16210 0077 2 x T 26/18 W 38 3,0 162 236/34/1 EVG 16210 0078 2 x T 26/36 W 34 7,0 162 236/50/1 EVG 16210 0079 2 x T 26/36 W 50 5,3 162 236/18/1 EVG 4) 5) 6) 16210 0062 2 x T 26/36 W 18 4,8 162 258/22/1 EVG 16210 0080 2 x T 26/58 W 22 5,8 162 258/31/1 EVG 16210 0081 2 x T 26/58 W 31 6,1 162 258/15/1 EVG 4) 5) 6) 16210 0063 2 x T 26/58 W 15 5,6 1) Wiring uncompensated only 2) Ratio effective lamp flux/nominal flux 3) Weights without packing material 4) MA version possible (see further series) 5) 3h emergency operation possible 6) shock proof versions Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 202

161/162... EVG for connection to central power supply unit For connection to group or central battery systems or to an emergency mains for illuminating escape routes, ships or vehicles etc. IP65 Electrical design: Electronic ballasts (230V AC / DC). A double lamp luminaire will be equipped with 2 electronic ballasts, separate lamp circuits and separate connection terminals.! T 26 162 2.. EVG T 38 Type Article no. Lamps/ Weight Watts approx. kg with electronic ballast (EVG) 161 118 EVG 2) 16100 0018 1 x T 26/18 W 1,5 161 136 EVG 16100 0019 1 x T 26/36 W 2,4 161 158 EVG 16100 0020 1 x T 26/58 W 3,0 with 2 individual electronic ballasts (EVG/2) 162 218 EVG/2 2) 16200 0353 2 x T 26/18 W 2,1 162 236 EVG/2 16200 0354 2 x T 26/36 W 2,5 162 258 EVG/2 16200 0356 2 x T 26/58 W 4,0 1) Weights without packing material Further series / equipment for series 161/162... only:.../b stand-by system = emergency lighting in case of mains failure only (series 162... with 1 lamp = 1621.. only).../p button for testing the emergency light function.../3 3 hour emergency operation for series 161/162... EVG only: with separate or integrated monitoring module for connection to group or central power supply unit with system for monitoring each individual luminaire. (For any inquiry please indicate the make of the equipment used.) with electronic ballast for voltages: 110V AC/DC, 24V DC Type 162 218... with legend.../35 for types 161/162.../.. EVG only:.../ma automatic monitoring the emergency light fitting with weekly functioning test and annual opwaking period test according to DIN VDE 0108, indication of the test results by LED (luminescence diode) at the luminaire. For further equipment please see catalogue section Dustproof / Waterproof luminaires of series 161/162... Emergency Notleuchten Light Fittings Self adhesive legends.../33 W.../34 W.../35 W for escape route identification acc. to BGV A8 and DIN 4844-2. Sighting distance acc. to EN 1838 and DIN 4844 = 25m. Accessories / Spare Parts Type Article no. Self adhesive legends for series 162 118 and 162 218 590/125/33 W 59000 0004 590/125/34 W 59000 0005 590/125/35 W 59000 0006 Emergency exit to the left Emergency exit to the right Emergency exit below For further accessories and spare parts please see catalogue section Dustproof / Waterproof luminaires of series 161/162... When ordering any electronic components or battery sets please do always indicate the type nos. of the light fittings. 203 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

Dustproof / Waterproof Polyester Emergency Light Fittings of Insulation Class I Series 163/164... For illumination of working places and acc. to DIN VDE 0108 for illuminating and identifying any escape routes etc. Mechanical Data: Housing: Glass fibre reinforced polyester resin, polyurethane gasket. Diffuser: Stippled clear acrylic (PMMA) with impact resistant component or polycarbonate (PC), hinged at one side. Closure: External plastic clips (KK). Stainless steel clips (KE) upon request and at extra charge. Reflector: Sheet steel, finished in white, detachable, carrying the electrical components. 'Quick release' turn buckle fasteners for quick installation. Connection: 4-pole connection terminal. Cable entries: At the small front sides and at the upper side of the housing, also for looping the mains cable at one side (types 1631.. also at the long side), 2 plugs M20. Through wiring system: Up to 7x2,5mm 2 or 5x4mm 2 (extra charge). Mounting system: 2 points for direct ceiling mounting; rubber gaskets and washers inside the fitting. Wiring diagram 163... maintained operation light switch Electrical Data: Incorporated NiCd battery set which is constantly charged and therefore ready for operation at any time. Visual monitoring the battery charging process by LED (luminescence diode). Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN 60598-2-22. Modes of functioning: Maintained operation = in case of mains failure 1 lamp is switched over to battery operation. Connection voltage: 230V, 50Hz (standard) Ambient temperatures: -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) Ambient temperature (EVG): -5 C up to +40 C (maintained version) Wiring diagram 164... maintained operation light switch Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1' 163/164... with battery set T 26 163 158/... Type Article no. Lamps/ Flux factor-weight Watts Watts approx. % 2) approx. kg 3) 1 hour emergency operation, with conventional ballast 163 136/18/1 16310 0001 1) 1 x T 26/36 W 18 3,4 163 158/15/1 16310 0002 1) 1 x T 26/58 W 15 4,3 164 218/38/1 16410 0017 2 x T 26/18 W 38 3,2 164 236/18/1 16410 0001 1) 2 x T 26/36 W 18 5,2 164 258/15/1 16410 0002 1) 2 x T 26/58 W 15 6,6 1 hour emergency operation, with electronic ballast (EVG) 163 136/18/1 EVG 16310 0005 1 x T 26/36 W 18 3,2 163 158/15/1 EVG 16310 0006 1 x T 26/58 W 15 3,4 164 218/38/1 EVG 16410 0018 2 x T 26/18 W 38 3,0 164 236/18/1 EVG 16410 0005 2 x T 26/36 W 18 4,1 164 258/15/1 EVG 16410 0009 2 x T 26/58 W 15 4,9 1) Wiring uncompensated only 2) Ratio effective lamp flux/nominal flux IP65 3) Weights without packing material 163... Series 163... Series 164... Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 204

163/164... EVG for connection to central power supply unit For connection to group or central battery systems or to an emergency mains for illuminating escape routes or for emergency lighting on ships, vehicles etc. IP65 Electrical design: Electronic ballasts (230V AC / DC). A double lamp luminaire will be equipped with 2 electronic ballasts, separate lamp circuits and separate connection terminals.! 164... EVG T 26 Type Article no. Lamps/ Weight Watts approx. kg 1) with electronic ballast (EVG) 163 118 EVG 2) 16300 0010 1 x T 26/18 W 1,3 163 136 EVG 16300 0011 1 x T 26/36 W 2,3 163 158 EVG 16300 0012 1 x T 26/58 W 2,6 with 2 individual electronic ballasts (EVG) 164 218 EVG/2 2) 16400 0145 2 x T 26/18 W 2,5 164 236 EVG/2 16400 0146 2 x T 26/36 W 3,7 164 258 EVG/2 16400 0147 2 x T 26/58 W 5,0 1) Weights without packing material Further series / equipment for series 163/164... only::.../b stand-by system = emergency lighting in case of mains failure only (series 164... with 1 lamp = 1641.. only).../p button for testing the emergency light function.../3 3 hour emergency operation Special version for wind power stations (see special data sheet). for series 163/164... EVG only: with electronic ballast (EVG) for the following voltages: 110 V DC, 24V DC with separate or integrated monitoring module for connection to group or central battery systems with device for monitoring each individual luminaire.(for any inquiry please indicate the make of the equipment used.). for series 163/164... EVG only:.../ma automatic monitoring the emergency light fitting with weekly functioning test and indication of the test results by LED (luminescence diode) at the luminaire For further equipment please see catalogue section Dustproof / Waterproof luminaires of series 163 / 164... Notleuchten für Windkraftanlagen auf Anfrage lieferbar. Emergency Notleuchten Light Fittings Type 164 218... with legend.../35 Self adhesive legends.../33 W.../34 W.../35 W for escape route identification acc. to BGV A8 and DIN 4844-2. Sighting distance acc. to EN 1838 and DIN 4844 = 25m. Accessories / Spare Parts Type Article no. Self adhesive legends for series 164 118 and 164 218 590/125/33 W 59000 0004 590/125/34 W 59000 0005 590/125/35 W 59000 0006 Emergency exit to the left Emergency exit to the right Emergency exit below For further accessories and spare parts please see catalogue section Dustproof / Waterproof luminaires of series 163/164... When ordering any electronic components or battery sets please indicate the type nos. of the light fittings. 205 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

Polyester Emergency/Escape Sign Light Fittings Series 164... KL B/D In humid, wet and dusty locations, commercial and industrial premises, agricultural buildings, car parks, basements, kitchens, protective locations for civil defence, for illumination and identification of escape routes. Mechanical Data: Housing: Glass fibre reinforced polyester, polyurethane gasket. Difuser: Clear stippled PMMA with impact resistant components, hingeable on both sides. Also available in white (W) or clear (K) PMMA or clear stippled (PC) or clear (K PC). Closure: plastic clips (KK). Stainless steel (KE) upon request and at extra charge. Reflector: Sheet steel finished white, detachable, carrying the electrical components. 'Quick release' turn buckle fasteners allow a quick installation. Connection: 3/4-pole connection terminal. Cable entries: At the small front sides and at the upper side of the housing, also for looping the mains cable at one side, 2 plugs M20. Through wiring system: At extra charge. Mounting system: 2 points for direct ceiling mounting; rubber gaskets and washers inside the fitting. Wiring diagram 164 1.. KL B stand-by Wiring diagram 164 1.. KL D maintained Electrical Data: NiCd battery set - gastight - mounted on the reflector. The battery set is constantly charged and therefore ready for operation at any time. Visual monitoring the battery charging process through LED (luminescence diode). Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN 60598-2-22. NEW Baureihe 164... LED: 3 x 1W LUXEON Highpower-LED NiMH-Batterie Modes of functioning:... B =stand-by operation = in case of mains failure the lamp is on.... D =maintained operation = in case of mains failure the lamp is switched over to battery operation. Connection voltage: 230V, 50Hz (standard) Ambient temperatures: -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) light switch Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1' 164... KL B/D / D with battery set T 16 TC-SEL 164 108 KL TC - L Type Article. Lamps/ Em.- Flux factor Weight no. Watts hours appr.% 2) kg 4) maintained or stand-by version 1) IP 65 164 108/45 KL B/D1 16409 0021 1 x T 16/8 W 1 45 2,0 164 108/36 KL B/D3 16409 0022 1 x T 16/8 W 3 36 2,2 164 111/25 KL B/D1 16409 0023 1 x TC-SEL 11 W 1 25 2,0 164 111/20 KL B/D3 16409 0024 1 x TC-SEL 11 W 3 20 2,4 stand-by version (B) 1) 164 118/39 KL B1 16409 0029 1 x TC-L 18 W 1 39 1,9 164 118/46 KL B3 16409 0030 1 x TC-L 18 W 3 46 2,4 maintained version (D) with electronic ballast (EVG) 164 108/45 KL D1 EVG 16409 0025 1 x T 16/8 W 1 45 1,7 164 108/36 KL D3 EVG 16409 0026 1 x T 16/8 W 3 36 2,3 164 111/25 KL D1 EVG 16409 0027 1 x TC-SEL 11 W 1 25 1,7 164 111/20 KL D3 EVG 16409 0028 1 x TC-SEL 11 W 3 20 1,9 1)Wiring uncompensated only 2) Ratio effective lamp flux/nominal flux 3) 4) Weights without packing material NEW 164... KL LED IP 65 Note: An EXIT sign on 2 sides requires 2 light fittings which are connected by means of a ceiling or a wall bracket (see accessories / spare parts). LED Type Article. Lamps/ Em.- Flux factor Weight no. Watts hours appr.% 2) kg 4) 164 301 W KL LED/1/MA 16409 0011 3 x LED 1 W 1 65 2,0 164 301 W KL LED/3/MA 16409 0012 3 x LED 1 W 3 30 2,0 Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 206

164... KL EVG for connection to central power supply unit IP 65 Series 164 1..KL SB Series 164 1..KL ST T 16 TC-SEL TC- L LED 164 108 KL 164 108 KL SB 164 111 KL ST For connection to group or central battery systems with/without monitoring the individual luminaires or for connection to an emergency mains for identifying and illuminating escape routes. Type Article no.. Lamps/ Weight Watts approx. kg 1) with electronic ballast (EVG) 164 108 KL EVG 16404 0084 1 x T 16/8 W 1,2 164 111 KL EVG 16404 0063 1 x TC-SEL 11 W 1,1 164 118 KL EVG 16404 0015 1 x TC-L 18 W 1,2 with high bay reflector (SB) and electronic ballast (EVG) 164 108 KL SB EVG 16404 0130 1 x T 16/8 W 1,2 164 111 KL SB EVG 16404 0142 1 x TC-SEL 11 W 1,2 164 118 KL SB EVG 16404 0154 1 x TC-L 18 W 1,3 with low bay reflector (ST) and electronic ballast (EVG) 164 108 KL ST EVG 16404 0124 1 x T 16/8 W 1,1 164 111 KL ST EVG 16404 0136 1 x TC-SEL 11 W 1,2 164 118 KL ST EVG 16404 0148 1 x TC-L 18 W 1,3 NEW Mechanical Data: Types...S. = with high or low bay reflector. Electrical Data: With electronic ballast (230V AC / DC). 164 301 W KL LED 16404 0500 3 x LED 1 W 1,1 1) Weights without packing material Series 164... KL with legend! Further series / equipment for series 164... KL B/D only: -.../P button for testing the emergency light function for series 164... KL B. and KL D. EVG: -.../MA automatic monitoring the emergency light fitting with weekly functioning test and indication of the test results by LED (luminescence diode) at the luminaire. for series 164... KL EVG only: - with electronic ballast (EVG) for the following voltages: 110 V DC, 24V DC, 12V DC - with separate or integrated monitoring module for connection to group or central battery systems with device for monitoring each individual luminaire. (For any inquiry please indicate the make of the equipment used.) For further equipment please see catalogue section Dustproof / Waterproof luminaires of series 163 / 164... KL Self adhesive legends green/white 1) 121/33 W 121/34 W 121/35 W for clear stippled or clear covers for escape route identification acc. to BGV A8 and DIN 4844-2. Sighting distance acc. to EN 1838 and DIN 4844 = 30m. 1) not for white opalescent covers Accessories / Spare Parts Type Article no. Spare glasses 164000 16413 9000 164000 W 16413 9001 164000 K 16413 9004 164000 PC 16413 9002 164000 K PC 16413 9005 Brackets WA 45 90232 0002 WA 90 90232 0003 DA 90232 0004 121/33 W 12112 0006 121/34 W 12112 0007 121/35 W 12112 0008 PMMA clear stippled PMMA white opalescent PMMA clear PC clear stippled PC clear wall bracket 45 wall bracket 90 ceiling bracket Standard legends, self adhesive (for clear stippled or clear light fittings) emergency exit left emergency exit right emergency exit below Further legends and wordings upon request. For further accessories and spare parts please see catalogue section Dustproof / Waterproof luminaires of series 164... KL When ordering any electronic components or battery sets please do always indicate the type nos. of the light fittings. Emergency Notleuchten Light Fittings 207 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

Small shock resistant Emergency/Escape Sign Light Fittings Series 131... B/D At working places and meeting places, humid and wet rooms, for illuminating and indicating escape routes. Mechanical Data: Housing: White polycarbonate. Diffuser: Injected, clear polycarbonate with internal prisms or white opalescent (W). Multiple hinge at one small side for suspending and unhinging purpose. Captive stainless steel screw on the other side for closing the fitting. Connection: 3- / 4-pole terminal. Cable entries: 1 plug M20 at each of the small sides. Mounting system: 2 points at the upper side of the housing for direct ceiling mounting; rubber gaskets and washers inside the fitting. Wiring diagram 131... D/B maintained/stand-by light switch Wiring diagram 131 1... B stand-by Electrical Data: (series 131... B/D only) NiCd battery set - gastight - mounted on the reflector. The battery set is constantly charged and therefore ready for operation at any time. Visual monitoring of the battery charging process by LED (luminescence diode). Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN 60598-2-22. Baureihe 131... LED: 2 x 1W LUXEON Highpower-LED NiMH-Batterie Modes of functioning:... B = stand-by operation = in case of mains failure the lamp is on.... D = maintained operation = in case of mains failure the lamp is switched over to battery operation.... MA = automatic monitoring the emergency light fitting with weekly functioning test and indication of the test results by LED (luminescence diode) at the luminaire. Connection voltage: 230V, 50Hz (standard) Ambient temperatures: -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) 131... B/D IP65 with battery set T 16 TC - L Type Article. Lamps/ Em.- Flux factor Weight no. Watts hours appr.% 2) kg 4) Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1' 131 108/.. B. maintained and stand-by version 1) 131 108/45 W B/D1 13110 0014 1 x T 16/8 W 1 45 1,3 131 108/36 W B/D3 13110 0015 1 x T 16/8 W 3 36 1,3 Shock resistance test: RK 1.0 / 10A NEW 131... LED stand-by version 131 118/39 W B1 13110 0018 1 x TC-L 18 W 1 39 1,3 stand-by version with automatic monitoring system 131 118/17 W B1 MA 13110 0022 1 x TC-L 18 W 1 17 1,1 131 118/17 W B3 MA 13110 0024 1 x TC-L 18 W 3 17 1,3 131 118/39 W B1 MA 13110 0020 1 x TC-L 18 W 1 39 1,3 maintained version with electronic ballast (EVG) and automatic monitoring system 131 108/45 W D1 EVG MA 13110 0016 1 x T 16/8 W 1 45 1,2 1) Wiring uncompensated only 2) Ratio effective lamp flux/nominal flux 3) Also available with MA 4) Weights without packing material IP65 with battery set Type Article. Lamps/ Em.- Flux factor Weight no. Watts hours appr.% 2) kg 4) 131 201 W LED/1 MA 13110 0100 2 x LED 1 W 1 65 1,0 131 201 W LED/3 MA 13110 0101 2 x LED 1 W 3 30 1,0 Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 208

! 131... EVG for connection to central power supply unit T 16 TC-SEL TC- L LED For connection to group or central battery systems or to emergency mains for illuminating escape routes or for emergency illumination on ships, vehicles etc. 131 108 LL EVG 13100 0047 1 x T 16/8 W W 0,8 131 111 EVG 13100 0013 1 x TC-SEL 11 W 0,7 131 118 EVG 13100 0015 1 x TC-L 18 W 0,7 131 111 EVG 24V DC 13100 0017 1 x TC-SEL 11W 1,0 131 111 EVG 12V DC 13100 0016 1 x TC-SEL 11W 1,0 NEW Type Article no. Lamps/ Weight Watts approx. kg 1 with electronic ballast (EVG) 131 201 W LED 13100 0100 2 x LED 1W 1,0 1) Weights without packing material Further series / equipment for series 131... B/D only:... P button for testing the emergency light function... EVG with electronic ballast Special version for wind power stations (Please ask for our special data sheet). IP65 Electrical Data: Electronic ballasts (230V AC / DC, 110V DC, 24V DC or 12V DC). A double lamp luminaire will be equipped with 2 electronic ballasts, separate lamp circuits and separate connection terminals. for series 131... EVG only: with conventional ballast 230V, 50Hz with separate or integrated monitoring module for connection to group or central battery systems with device for monitoring each individual luminaire. (For any inquiry please indicate the make of the equipment used.) For further equipment please see catalogue section Dustproof / Waterproof luminaires of series 130 / 131 / 132... Type 131... with standard legend Self adhesive legends for escape route identification acc. to BGV A8 and DIN 4844-2. Sighting distance acc. to EN 1838 and DIN 4844 = 15m. Accessories / Spare Parts Type Article no. Standard legend, self adhesive 265/76/3 90011 0002 Note: Further legends and wordings upon request. Emergency Notleuchten Light Fittings For further accessories and spare parts please see catalogue section Dustproof / Waterproof luminaires of series 130/131/132... When ordering any electronic components or battery sets please indicate the type nos. of the light fittings. 209 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

Dustproof/Waterproof Polyester Emergency Light Fittings of Insulation Class II - without diffuser Series 175... For illumination of working places and acc. to DIN VDE 0108 for illuminating and identifying escape routes etc. Mechanical Data: Housing: Glass fibre reinforced polyester resin. Gasket: Weatherproof, non-ageing and chemically resistant profile gasket. Electrical components: Mounted on the inner side of the suspended polyester lid. Starter easily accessible from outside the fitting. Moisture-proof lampholders with rotating contact system, neoprene gasket. Cable entries: At the small front sides and at the upper side of the housing, also for looping the mains cable at one side. 2 plugs M20. Connection: 3-pole connection terminal. Through wiring system: Up to 5 x 2,5mm 2 possible, at extra charge. Mounting system: Closed knock-outs for direct ceiling mounting; rubber gaskets and washers inside the fitting. Wiring diagram 175 1... maintained operation light switch Wiring diagram 175 2... maintained operation Electrical Data: (series175...only) Incorporated NiCd battery set which is constantly charged and therefore ready for operation at any time. Visual monitoring the battery charging process by LED (luminescence diode). Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN 60598-2-22. Luminous flux raising i.e. initially the emergency lamp has got a higher luminous flux. Only one lamp is operating in the emergency case. Modes of functioning: Maintained operation = in case of mains failure 1 lamp is switched over to battery operation. Connection voltage: 230V, 50Hz (standard) Ambient temperatures: -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) light switch Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1' Series 175 1.. Series 175 2.. 175... with battery set T 26 Type Article no. Lamps/ Flux factor Weight Watts approx. % 2) approx. kg 3) 1 hour emergency operation, with conventional ballast IP65 175 158/../. 175 136/18/1 3) 17510 0005 1) 1 x T 26/36 W 18 2,7 175 158/15/1 3) 17510 0006 1) 1 x T 26/58 W 15 3,2 175 236/18/1 17510 0007 1) 2 x T 26/36 W 18 4,6 175 258/15/1 17510 0008 1) 2 x T 26/58 W 15 5,7 1 hour emergency operation, with electronic ballast (EVG) 175 136/18/1 EVG 3) 17510 0009 1 x T 26/36 W 18 2,3 175 158/15/1 EVG 3) 17510 0010 1 x T 26/58 W 15 2,5 175 236/18/1 EVG 3) 17510 0011 2 x T 26/36 W 18 3,2 175 258/15/1 EVG 3) 17510 0012 2 x T 26/58 W 15 2,6 1) Wiring uncompensated only 3) Weights without packing material 2) Ratio effective lamp flux/nominal flux Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 210

175... EVG for connection to central power supply unit For connection to group or central battery systems or to an emergency mains for illuminating escape routes, ships or vehicles etc. IP65 Electrical design: Electronic ballast (230V AC / DC, 110V DC, 24V DC). A double lamp luminaire will be equipped with 2 electronic ballasts, separate lamp circuits and separate connection terminals.! 175 258 EVG T 26 Type Article no. Lamps/ Weight Watts approx. kg 1 with electronic ballast (EVG) 175 118 EVG 1) 17500 0019 1 x T 26/18 W 0,8 175 136 EVG 17500 0020 1 x T 26/36 W 1,4 175 158 EVG 17500 0021 1 x T 26/58 W 1,6 with 2 individual electronic ballasts (EVG/2) 175 236 EVG/2 17500 0226 2 x T 26/36 W 1,6 175 258 EVG/2 17500 0225 2 x T 26/58 W 1,8 1) Weights without packing material Further series / equipment for series 175.../.../. only:.../b stand-by system = emergency lighting only in case of mains failure.../3 3 hour emergency operation for series 175.../../. EVG only:.../ma automatic self-monitoring and indication of the results, weekly functioning test and yearly long-time test acc. to DIN VDE 0108. for series 175... EVG only: with separate or integrated monitoring module for connection to group or central battery equipment with system for monitoring each individual luminaire. (For any inquiry please indicate the make of the used equipment.). with electronic ballast for special voltages: 110V DC, 24V DC with conventional ballast 230V, 50 Hz for both series: with external reflectors with rotable snap-on reflectors with protective tube S38 or S50 with oval-shaped protective tube S0 also in FF version with through wiring system up to 5x2,5mm 2 with different cable entries up to M25 x 1,5 for fluo tubes of 38mm Ø (with enlargement rings 1681/38) Emergency Notleuchten Light Fittings Accessories / Spare Parts For accessories and spare parts please see catalogue section Dustproof / Waterproof luminaires of series 175... When ordering any electronic components or battery sets please do always indicate the type nos. of the light fittings. 211 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

NEW 401... IP40 T 16 3 170 x 321 x 77 (102*) 7 246 x 321 x 77 (102*) (* bei Pendel-, Wandausleger- bzw. Deckenauslegermontage) 401 108/3 D1 EVG 40100 0015 3 30 m 1 x T 16/8 W 401 108/3 D3 EVG 40100 0016 3 30 m 1 x T 16/8 W 401 108/7 D1 EVG 40100 0017 7 40 m 1 x T 16/8 W 401 108/7 D3 EVG 40100 0018 7 40 m 1 x T 16/8 W Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 212

201... IP40 T 16 TC-SEL 201 106/1 EVG 20100 0001 1 20 m 1 x T 16/6 W 1,0 201 109/1 EVG 20100 0002 1 20 m 1 x TC-SEL 9 W 1,0 201 108/3 EVG 20100 0003 3 30 m 1 x T 16/8 W 1,3 201 111/3 EVG 20100 0004 3 30 m 1 x TC-SEL 11 W 1,3 201 108/7 EVG 20100 0005 7 40 m 1 x T 16/8 W 1,6 201 111/7 EVG 20100 0006 7 40 m 1 x TC-SEL 11 W 1,6! Weitere Baureihen / Ausführungen Emergency Notleuchten Light Fittings.../33.../34.../33.../34.../35.../35.../99.../98.../90 213 Bitte beachten Sie die Hinweise im Technischen Anhang!

NEW Emergency Light Power Supply Unit Series N 12... As power supply for light fittings with up to 200W which are installed separately from the "N"-device in a different room. It is especially recommended in cases in which the existing environmental conditions prohibit the use of fittings with individual battery sets. Mechanical design: Housing: Polycarbonate, grey (RAL 9006) Battery and electronic device: Each in a separate housing acc. to DIN EN 50272-2. Battery compartment with aeration opening Mounting: Direct wall mounting (borings of Ø 6.0 mm) Installation: Plug-type terminals (up to 2.5mm²) Admissible ambient temperature: -5 C up to +35 C Insulation class: I Attention: Installation of this power supply unit is allowed outside the hazardous area only. Distance between the light fitting and the "N" unit: 500m max.voltage drop to be considered acc. to VDE 0100. Wiring diagrams for electronic ballast types: mains unswitched mains switched ligh fittings output interface control input stand by Electrical design: Emergency power supply unit with battery for operating 1 or 2 fluorescent light fittings with electronic ballast (EVG) Emergency light electronic device with deep discharge protection and switchover system for mains/emergency operation As a standard with self monitoring device, performing automatic weekly functional and annual operating period tests. The consumer loads will be monitored by a self- adjusting performance control device. Manual actuation of the functional tests and display of messages and malfunctions via a combined foil touch screen. Interface for remote controlling the operating state via external switch. Interface for malfunction indication Battery set: With maintenance-free lead-battery Modes of operation: Maintained or stand-by operation Maintained operation: Switching to battery operation in case of mains failure. Stand-by operation: Emergency lamp switches on in case of mains failure only. Rated voltage: 230V / 50Hz Suitable for: Fluorescent light fittings with electronic ballast (EVG): For double lamp fittings with double EVG, please consider double consumption or use fittings with 2 EVGs (separating the systems) Note: The EVGs in the light fittings connected to the power supply unit must be suitable for DC and AC operation and for application in an equipment acc. to DIN VDE 0108. Light fittings for incandescent lamps. Admissible consumption acc. to the admissible consumption of the fluorescent tubes. N12/... 18Ah N12/... 45Ah N 12... with separate housing each for the inverter and for the battery set inverter IP65 IP54 batterie set IP32 N12/... 12/24Ah N12/... 90Ah Type Article no. Lamps/ Flux factor Weight Watts approx.% 1) appr. kg 2 for light fittings with electronic ballast (EVG)- 1 hour operating N12/118-58/12/1 DC 12000 0050 1 x 18 58 W 100 7,1 N12/218-36/18/1 DC 12000 0051 2 x 18 36 W 100 8,8 N12/258/24/1 DC 12000 0052 2 x 58 W 100 12,8 for light fittings with electronic ballast (EVG)- 3 hours operating N12/118-58/45/3 DC 12000 0053 1 x 18 58 W 100 19,2 N12/218-36/45/3 DC 12000 0054 2 x 18 36 W 100 19,2 N12/258/90/3 DC 12000 0055 2 x 58 W 100 35,5 1) Ratio effective flux/rated lamp flux 2) Weights without packing material Emergency Light Fittings! Further series / equipment Special version for operating fittings with conventional ballasts with electronic starter with a DC/AC converter which will provide a cascaded 230V / 50Hz AC supply with 80VA. Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 214

Elektroniks chrank IP54 Batterieschrank IP32 Emergency Notleuchten Light Fittings 215 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

Elektroniks chrank IP54 Batterieschrank IP32 Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 216

Emergency Notleuchten Light Fittings 217 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!