System Manual 1+n technology Issue 2013
|
|
|
- Gervais Blake
- 10 years ago
- Views:
Transcription
1 System Manual 1+n technology Issue 2013
2 Contents 1 1+n technology System description 3 2 Safety remarks 3 3 Configuration, conductor lengths 1+n technology 4-5 Overview 6 4 Device overview Door loudspeakers, call buttons 8 Door station 9 Power supply, line rectifiers 10 Controller 11 DoorCom 12 In-house telephones, accessories 13 5 Installation Door station installation AS-Ta-64/1 Siedle Vario 16 AS-Ta-64/1 Siedle custom-fit door loudspeaker 18 AS-Ta-64/1 Siedle Classic 20 AS-Ta-64/1 Siedle Steel 22 AS-Ta-64/1 Siedle Vario with DoorCom Analog DCA AS-Ta-64/2 Siedle Vario with 2 door stations 26 AS-Ta-64/2 Siedle custom-fit door loudspeaker with 2 door stations 28 AS-Ta-64/3 Siedle Vario with 3 door stations 30 AS-Ta-74/1 Siedle Vario, internal speech communication 32 AS-Ta-84/1 Siedle Vario 1 main door station, 1 storey door station 34 AS-Ta-85/1 Siedle Vario 1 main door station, 1 storey door station, internal speech communication 36 AS-Ta-94/1 Siedle Vario, group switching with internal speech communication 38 6 Supplementary functions Group controller GC Switching/remote controller SFC Storey controller ETC Secondary signal controller NSC Controller door release CTÖ Parallel switching in-house telephones 48 Secondary signal unit NS Pilfer safeguard DSC Staircase light/outside light 50 LED actuation, potential-free buttons 51 7 Servicing Exchange/extension 52 Measured values 54 Glossary, Index 55 2
3 1 1+n technology System description 2 Safety remarks Wire-saving 1+n technology Configuration The wire-saving 1+n system is based on an installation with a common core and a call core ãn for each user which links the bell button at the front door directly to each inhouse telephone. Using these two cores, all the functions are implemented, i.e. ringing, speech, door release and switching functions. Up to door 8 door stations can be operated in parallel without the need for any further accessories. At each in-house telephone, a storey call button can be connected which allows direct calls to be placed to the apartment door. Actuation of the door release always takes place for the door station from which the door bell was pressed. There is one speech channel available within the 1+n system; The number of speech channels can be increased by adding further controllers. In the plans, the joint core is laid to terminal 1 and the calling core ãn to terminal 7. Both cores must be routed within the same cable. Terminal 7 is supplied with power in its idle status via the call button module with direct voltage. As long as the call button remains depressed, the voltage continues to rise to its full value. No programming is required for the basic functions ringing, speech, door release. Mounting, installation and servicing work on electrical devices may only be performed by a suitably qualified electrician. Failure to observe this regulation could result in the risk of serious damage to health or fatal injury due to electric shocks. When working at the device, observe the remarks relating to mains cut-off. Observe the DIN EN standard! When establishing the electronic connection, observe the requirements of VDE 0805 or EN The building installation must include an all-pole mains switch with a contact separation of at least 3 mm. Ensure maximum fusing of 16A for the mains connection in the building installation. When planning large-scale (complex) systems, the distributor space required for the switch panel mounting devices must be taken into consideration in the distributor planning process. No external voltages >30 V AC/DC may be applied to system users. Devices with 230 V connection In accordance with DIN VDE 0100 part 410, section attention must be paid to ensuring a safe separation between system lines and the mains voltage; i.e. system and mains cores must not be permitted to touch! The system line cable (extra-low safety voltage) must be stripped back by the minimum possible. 3
4 3 Configuration, conductor lengths 1+n technology Configuration of the 1+n system The basic installation is performed as a side circuit installation.the door stations and in-house telephones are routed to the sub-distributor. Installation can be performed as a star, tree or bus structure. The door station and in-house telephones are linked by means of terminals 1 and 7. The side circuit cores are routed to terminal 1 ( potential), the calling cores to terminal 7. Terminal + is used as a reference terminal for the apartment bell button ERT and to supply the three-tone chime (terminal G) of the deluxe in-house telephone. Jumpers are inserted within the door station to link the door loudspeaker terminal block and the terminal block of one or more call button modules. Jumpers are inserted between terminal 6 and 6, terminal 11 and 11 and terminal + and + for all call button modules. Where there are several door stations, from the second door station the jumper between + and + to the call button module is only required at one door loudspeaker. Depending on the door loudspeaker used, terminals b and c should be bridged differently. For precise instructions, see chapter 5. Functional characteristics The bias current to terminals 1 and 7 is 18 V DC. When pressing the bell button, the voltage rises to 24 V DC and then drops to around 15 V DC. After picking up the receiver, a speech connection is created between the door station and the in-house telephone. For 30 seconds after replacing the receiver, the speech connection can be re-established by lifting the receiver again. The system then returns to idle voltage and the audio privacy device is activated. The audio privacy device ensures that a call can only be accepted at the in-house telephone at which the front doorbell rang. Functions Door call: Ringing at the front door (door station) and speech connection Storey call: An apartment bell (ERT) can be connected to each in-house telephone Door release: Pressing the door release button at the in-house telephone switches the DR contact in the door loudspeaker module to terminal c, duration fixed at 3 seconds Light switching: Pressing the light button at the in-house telephone switches the Li contact in the door loudspeaker module to terminal c, duration fixed at 0.8 seconds Other functions are possible using additional controllers: Group controller: Permits internal speech operation between 6 in-house telephones or parallel switching of up to 6 in-house telephones at one bell button Storey controller: permits the connection of door stations to one or more storeys Switching and remote controller permits switching and control functions via the in-house telephones Door release controller: takes care of tamper-proof operation of the door release Power supply The line rectifier NG 602- supplies the door station with the following voltages: +/ 24 V DC for speech and control b/c 12 V AC for illumination of the call button module and door release 4
5 For the entire conductor length in the 1+n system, the following applies: with cable material YR or J Y(St)Y with 0.8 mm diameter max. 500 m/1640 ft between the door station and the most distant inhouse telephone max. 100 m/328 ft between the line rectifier and the most distant door station max. 500 m/1640 ft core length TLn between several door stations With cable material YR or J Y(St)Y with 0.6 mm diameter max. 250 m/820 ft between the door station and the most distant in-house telephone max. 50 m/164 ft between the line rectifier and the most distant door station max. 250 m/820 ft core length TLn between several door stations 5
6 3 Configuration, conductor lengths Overview Parallel door stations Up to 8 door stations can be connected in parallel without the need for any further accessories. The door loudspeakers become synchronized one with the other via terminals TLn. Parallel in-house telephones or accessories Up to 2 in-house telephones can be operated in parallel, e.g. HTS 811- and HTC 811- With the GC 612- up to 6 in-house telephones can be called in parallel via a call button. Secondary signal unit NS 711- and secondary signal controller NSC 602- count as parallel devices Storey call ERT Every in-house telephone has a terminal ERT for a storey call button. The storey call button (ERT) is used for ringing at the apartment door. Storey door station Instead of a storey call button ERT a door station is also possible on a storey. To connect a storey door station, the storey controller ETC 602- is required. Internal speech Speech is possible between the inhouse telephones HTC 811- For this function, the controller GC 612- is required Switching and control functions Switching and control functions can be initiated from the deluxe inhouse telephone HTC 811- For the implementation of control functions, the switching/remote controller SFC 602- is required. Buttons 5 and 6 can be used as potential-free buttons. The buttons can be made potential free using a DIL switch in the in-house telephone. Pick-up at terminals T5/T5 and T6/T6. Connection of the telephone system One or more door stations using 1+n technology can be connected using the DoorCom Analog DCA 612- to the analogue PBX extension of a telephone system. Up to three call buttons can dial a PBX extension in the telephone system or a telephone number. Dialling takes place using the dual tone multiple frequency method DTMF. Door release Every door loudspeaker has an integrated relay to actuate a door release. The relay contact switches the door release button in the inhouse telephone on actuation for 3 seconds. It only switches the door release of the door at which the bell was rung. To ensure tamper-proof switching of the door release, the door release controller CTÖ 602- has to be used. Name plate lighting The call button modules and the info module are equipped with LED lighting. The current consumption of a module amounts to max. 20 ma. Door station light button The door loudspeaker module TLM 612- has a relay for actuation of an outdoor light. The contact T1 to T2 switches when the light button in the door loudspeaker is actuated for as long as the light button remains depressed. In-house telephone light button Each in-house telephone has a light button to actuate a joint staircase or entrance light. Evaluation of the contact takes place in the door loudspeaker module. On actuation of the light button at the in-house telephone, the relay contact switches for 0.8 seconds from terminal c to Li. Where there are several doors, the relay contact switches at the door station from which the last call was made. Secondary signal unit A secondary signal unit NS 711- can be connected in parallel to an in-house telephone in order to additionally signal the call in another room. A maximum of 1 secondary signal unit can be connected to an in-house telephone. Secondary signal controller Using the secondary signal controller NSC 602- a potential-free contact can be made available each for the door and storey call, e.g. to actuate a radio-controlled chime. 6
7 7
8 4 Device overview Door loudspeakers, call buttons TLM Door loudspeaker module for the wire-saving 1+n system. Front louvre made of weather- and UV-proof polycarbonate, tropicalized loudspeaker, long-life electret microphone with volume controller for loudspeaker. With integrated switching unit for automatic synchronization of several door loudspeakers, and floating contacts for door release and light. The module can be triggered directly from the in-house telephone via the wiresaving side circuit installation. connection facility for SFC and CTÖ Acoustic feedback when pressing one of the call buttons at the TM to -4 TM TM Call button module for wire-saving 1+n system. 1-4 call buttons, integrated LED lighting, connection via terminal block. Supply to the LED lighting via terminal b and c with 12 V AC, current consumption 20 A per call button module TM 612- TLE Custom-fit door loudspeaker for wire-saving system with HTS/HTC for customer s intercom compartments, door designs, letterbox systems etc. With automatic synchronization of several door loudspeakers, and floating contacts for door release and light. Can be screwed directly onto louvre ZJ Loudspeaker with volume controller. ZD The accessory diode must be used with wire-saving 1+n technology with HTS/HTC in conjunction with custom-fit loudspeaker TLE 061, for customer s bell panels. An accessory diode ZD is required for each started group of 10 call buttons. 8
9 4 Device overview Door station Siedle Classic CL A 01 N-02 - CL A 08 N-02 Door station with stainless steel front. Door loudspeaker and illuminated call buttons. Integrated door release contact (DR), contact load max. 15 V AC, 30 V DC, 2A, switching time DR fixed at 3 seconds. Current consumption for LED lighting of bell buttons, per button 5 ma, 12 V AC. Acoustic feedback when the call button is pressed. Siedle Steel STL... Door station with stainless steel front, door loudspeaker and call buttons. Integrated door release contact (DR), contact load max. 15 V AC, 30 V DC, 2 A, switching time DR fixed at 3 seconds. Current consumption for LED lighting of bell buttons, per button 3 ma, 12 V AC. Acoustic feedback when the call button is pressed. 9
10 4 Device overview Power supply, line rectifiers Controller NG Bus line rectifier in a 6-grid housing. Primary: 230 V AC, 50/60 Hz Secondary: 12 V AC, 1.6 A and 23.3 V DC A stabilized. Supply to the 1+n system, door release and lighting for the call button modules. TR Transformer in a 3-grid housing. Primary: 230 V AC, 50/60 Hz Secondary: 12 V AC, 1.3 A Additional supply for lighting the name signs or door releases. GC Group controller in 6-grid housing for internal speech operation. Connection of max. 6 in-housetelephones HTC 811- Calls can be made between the connected inhouse telephones. 8 DIL switch for programming. Supply 24 V DC, max. 300 ma Max. contact load for secondary signal unit 24 V, 2 A AC/DC 10
11 4 Device overview Controller SFC Switching/remote controller in 3-grid housing for the execution of 4 switching/control functions. 1 relay with changeover contact and 3 relays with 1 working contact each. Actuation using buttons 1 6, light or door release possible. Supply 12 V DC, max. 250 ma Max. contact load 24 V, 2 A AC/DC ETC Storey controller in 6-grid housing for connection to one or more storey door stations. During a call from a storey door station to an in-house telephone, an additional call can be routed from a main door station to another in-house telephone. Supply 24 V DC, max. 60 ma CTÖ Controller door release in a 3-grid housing for actuation of a door release which for safety reasons should not be connected directly to the door loudspeaker. Door release time fixed at 3 seconds. Supply 12 V DC, max. 70 ma Max. contact load 24 V, 2 A NSC Secondary signal controller for door calls, suitable for mounting in a 55 junction box, for connection of a secondary signal unit with its own power supply to the HTS/ HTC , with screw-type terminals. Contact type: changeover contact max. 24 V, 2 A Protection system: IP 20 Dimensions (mm) dia. x H: 51 x 23 11
12 4 Device overview DoorCom DCA DoorCom-Analog for connection of one or more door stations to an analog PBX extension of a telephone system. Up to 3 call buttons can be connected. 12 V AC supply to terminals b/c, connection to the 1+n system using cores 1 and ZR Time relay ZR in a 3 grid housing with electronic control, particularly suitable for use as a light time switch with LED function display, continuous light switch and 2 potential-free changeover contacts. Operating voltage V AC/DC control voltage 230 V AC and/or V AC/DC, galvanically isolated by optocouplers, OFF delay adjustable from 15 seconds up to 12 minutes ±30%. 12
13 4 Device overview In-house telephones, accessories HTS Standard in-house telephone with the functions: Calling, speech, door release and storey call Door release and light button Rotary controller for ring tone volume with integrated muting Door call as 3-tone call, storey call as 2-tone call Call volume max. 83 db (A) HTC Deluxe in-house telephone with the functions: Calling, speech, door release and storey call Door release and light button Rotary controller for ring tone volume with integrated muting 6 buttons for switching and control functions, of which two with switchover facility as potential-free buttons Internal speech communication with GC LEDs under the buttons to display switching statuses Door call as 3-tone chime, storey call as 2-tone call Call volume max. 83 db A ZTS Table-top accessory for telephones BTS/BFS/BFC and HTS for conversion from a wall to a tabletop unit. Slip-proof console with 2 rubber feet but without UAE 8(8) junction box. ZTC Table-top accessory for the telephone BTC and HTC for conversion from a wall to a tabletop unit. Slip-proof console with 2 rubber feet but without UAE 8/8(8) junction box. NS Secondary signal unit in a low-profile surface-mounting design with loudspeaker, externally adjustable volume control and electronic call generator. 13
14 5 Door station installation Terminal 1 All in-house telephones Subdistributor for NG Subdistributor for NG In-house telephone (no.1) terminal 7 In-house telephone (no.2) terminal 7 In-house telephone (no.3) terminal 7 In-house telephone (no.4) terminal 7 Door station installation The door loudspeaker module (TLM 612- and call button module TM 612- ) are each inserted in the relevant terminal block. The circuit diagram illustrates the two terminal blocks of the TLM 612- and TM 612- When switching several doors in parallel the terminal TLn must be connected between the door stations to allow synchronization between the door loudspeakers. The jumper of terminal + between the door loudspeaker and call button module must only be inserted at one door station when switching several doors in parallel. Steuerung Block diagram of door loudspeaker module TLM 612- Terminals of the door loudspeaker module TLM 612- Potential-free light button T1/T2 Door release contact c/dr Light contact from telephone c/li Vc actuation for video Terminal 6 call voltage Terminal 11 call current recognition D+/D actuation for SFC 602- / CTÖ reference terminal for 1+n TLn for synchronization of several door stations +/ supply voltage 24 V DC 14
15 Block diagram of the call button module TM In the idle status, the in-house telephone is supplied with power via the terminal +. Potential-free call contact between terminal 6 and 7.1 The audio privacy device in the door loudspeaker is actuated and communication takes place via terminal
16 5 Installation AS-Ta-64/1 Siedle Vario Appliance requirement Remarks 16
17 AS-Ta-64/1 Siedle Vario Functional Calling and speech between the door station and connected in-house telephones HTS/HTC 811- An existing call cannot be listened in to from other in-house telephones. Internal speech communication between the HTC 811-, which is connected to the GC 612- Dialling the user with the call buttons on the telephones. The assignment sequence corresponds to the sequence of call buttons. Door release button for the door release function, light button for the light switching function. Illuminated light button at the door station with potential-free switching contact. Connection of a storey call button (ERT) for calling from an apartment door. Different ring tones for calls from the front door, apartment door and for internal calls. Call tones with HTS 811- A call from the door produces a 3-tone call, from the storey door a 2-tone call. Call tones with HTC 811- On a door call, a 3-tone chime sounds, without connection of terminal G a 3-tone call. A storey call produces a 2-tone call, an internal call a 3-tone call. Connection of additional in-house telephones or door stations possible without switchover device. To ensure tamper-proof connection of the door release, the door release controller CTÖ 602- has to be used. Additional cores are required for this. Supplementary functions Internal speech communication between the in-house telephones HTC 811- and group controller GC 612- is possible. Switching and control functions are possible with the switching/ remote controller SFC 602- A secondary signal unit NS 711- is possible in parallel with an inhouse telephone HTS/HTC 811- A parallel door call to a maximum of 2 HTS/HTC 811- units or NSC 602- /NS 711- is possible simultaneously. Using the group controller GC 612- a parallel call is possible to up to 6 in-house telephones. Remarks a) Line rectifier NG 602 can supply 1 door release and a maximum of 50 call button modules with LED lighting TM 612 1, -2, -3, and -4. With more than 50 illuminated call button modules, an additional TR 603 is required. 12 V AC consumers in the AS plan: Door release appr. 600 ma LED lighting per call button module 20 ma Door release contact load in the door loudspeaker max. 24 V AC, 2 A Light contact load in the door loudspeaker max. 24 V AC, 2 A b) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615 ) c) Conductor length from the in-house telephone to the storey call button ERT max. 50 m/164 ft. The light button in the in-house telephone switches the contact in the door loudspeaker from c to Li for 0.8 seconds, load max. 24 V, 2 A. 17
18 5 Installation AS-Ta-64/1 Siedle custom-fit door loudspeaker Appliance requirement Remarks Siedle Custom-fit door loudspeaker 18
19 AS-Ta-64/1 Siedle custom-fit door loudspeaker Functional Calling and speech between the door station and connected in-house telephones HTS/HTC 811- An existing call cannot be listened in to from other in-house telephones. Internal speech communication between the HTC 811-, which is connected to the GC 612- Dialling the user with the call buttons on the telephones. The assignment sequence corresponds to the sequence of call buttons. Door release button for the door release function, light button for the light switching function. Illuminated light button at the door station with potential-free switching contact. Connection of a storey call button (ERT) for calling from an apartment door. Different ring tones for calls from the front door, apartment door and for internal calls. Call tones with HTS 811- A call from the door produces a 3-tone call, from the storey door a 2-tone call. Call tones with HTC 811- On a door call, a 3-tone chime sounds, without connection of terminal G a 3-tone call. A storey call produces a 2-tone call, an internal call a 3-tone call. Connection of additional in-house telephones or door stations possible without switchover device. To ensure tamper-proof connection of the door release, the door release controller CTÖ 602- has to be used. Additional cores are required for this. Supplementary functions Internal speech communication between the in-house telephones HTC 811- and group controller GC 612- is possible. Switching and control functions are possible with the switching/ remote controller SFC 602- A secondary signal unit NS 711- is possible in parallel with an inhouse telephone HTS/HTC 811- A parallel door call to a maximum of 2 HTS/HTC 811- units or NSC 602- /NS 711- is possible simultaneously. Using the group controller GC 612- a parallel call is possible to up to 6 in-house telephones. Remarks a) The NG is also able to supply the customer's own call buttons. A voltage of 12 V AC max. 1 A is available for the lighting if a door release with an impedance of at least 20 Ohm is used. With a higher current consumption, an additional transformer must be used. 12 V AC consumers in the AS plan: Door release appr. 600 ma Door release contact load in the door loudspeaker max. 24 V AC, 2 A Light contact load in the door loudspeaker max. 24 V AC, 2 A b) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615- c) Conductor length from the inhouse telephone to the storey call button ERT max. 50 m/164 ft. The light button in the in-house telephone switches the contact in the door loudspeaker from c to Li for 0.8 seconds, load max. 24 V, 2 A. 19
20 5 Installation AS-Ta-64/1 Siedle Classic Buttons Appliance requirement Remarks 20
21 AS-Ta-64/1 Siedle Classic Functional Calling and speech between the door station and connected in-house telephones HTS/HTC 811- An existing call cannot be listened in to from other in-house telephones. Internal speech communication between the HTC 811-, which is connected to the GC 612- Dialling the user with the call buttons on the telephones. The assignment sequence corresponds to the sequence of call buttons. Door release button for the door release function, light button for the light switching function. Illuminated light button at the door station with potential-free switching contact. Connection of a storey call button (ERT) for calling from an apartment door. Different ring tones for calls from the front door, apartment door and for internal calls. Call tones with HTS 811- A call from the door produces a 3-tone call, from the storey door a 2-tone call. Call tones with HTC 811- On a door call, a 3-tone chime sounds, without connection of terminal G a 3-tone call. A storey call produces a 2-tone call, an internal call a 3-tone call. Connection of additional in-house telephones or door stations possible without switchover device. To ensure tamper-proof connection of the door release, the door release controller CTÖ 602- has to be used. Additional cores are required for this. Supplementary functions Internal speech communication between the in-house telephones HTC 811- and group controller GC 612- is possible. Switching and control functions are possible with the switching/ remote controller SFC 602- A secondary signal unit NS 711- is possible in parallel with an inhouse telephone HTS/HTC 811- A parallel door call to a maximum of 2 HTS/HTC 811- units or NSC 602- /NS 711- is possible simultaneously. Using the group controller GC 612- a parallel call is possible to up to 6 in-house telephones. Remarks a) Line rectifier NG 602- can supply 1 door release and lighting for appr. 200 call buttons. With more than 200 illuminated call button modules, an additional TR 603- is required. 12 V AC consumers in the AS plan: Door release appr. 600 ma LED lighting per call button 5 ma Door release contact load in the door loudspeaker max. 24 V AC, 2 A Light contact load in the door loudspeaker max. 24 V AC, 2 A b) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615- ) c) Conductor length from the in-house telephone to the storey call button ERT max. 50 m/164 ft. The light button in the in-house telephone switches the contact in the door loudspeaker from c to Li for 0.8 seconds, load max. 24 V, 2 A. 21
22 5 Installation AS-Ta-64/1 Siedle Steel Buttons Appliance requirement Remarks 22
23 AS-Ta-64/1 Siedle Steel Functional Calling and speech between the door station and connected in-house telephones HTS/HTC 811- An existing call cannot be listened in to from other in-house telephones. Internal speech communication between the HTC 811-, which is connected to the GC 612- Dialling the user with the call buttons on the telephones. The assignment sequence corresponds to the sequence of call buttons. Door release button for the door release function, light button for the light switching function. Illuminated light button at the door station with potential-free switching contact. Connection of a storey call button (ERT) for calling from an apartment door. Different ring tones for calls from the front door, apartment door and for internal calls. Call tones with HTS 811- A call from the door produces a 3-tone call, from the storey door a 2-tone call. Call tones with HTC 811- On a door call, a 3-tone chime sounds, without connection of terminal G a 3-tone call. A storey call produces a 2-tone call, an internal call a 3-tone call. Connection of additional in-house telephones or door stations possible without switchover device. To ensure tamper-proof connection of the door release, the door release controller CTÖ 602- has to be used. Additional cores are required for this. Supplementary functions Internal speech communication between the in-house telephones HTC 811- and group controller GC 612- is possible. Switching and control functions are possible with the switching/ remote controller SFC 602- A secondary signal unit NS 711- is possible in parallel with an inhouse telephone HTS/HTC 811- A parallel door call to a maximum of 2 HTS/HTC 811- units or NSC 602- /NS 711- is possible simultaneously. Using the group controller GC 612- a parallel call is possible to up to 6 in-house telephones. Remarks a) Line rectifier NG 602- can supply 1 door release and lighting for appr. 330 call buttons. With more than 330 illuminated call button modules, an additional TR 603- is required. 12 V AC consumers in the AS plan: Door release appr. 600 ma LED lighting per call button 3 ma Door release contact load in the door loudspeaker max. 24 V AC, 2 A Light contact load in the door loudspeaker max. 24 V AC, 2 A b) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615- ) c) Conductor length from the in-house telephone to the storey call button ERT max. 50 m/164 ft. The light button in the in-house telephone switches the contact in the door loudspeaker from c to Li for 0.8 seconds, load max. 24 V, 2 A. The Siedle-Steel door station STL is fully wired in the factory. If there are several door stations integrated in the system, with the 2nd to the xth STL the door intercom system must be removed in each case and the jumpers located behind it from + and 7.1 to + and 7.5 and also if applicable + and 7 must be taken out. For instructions on how to remove the jumpers, refer to the Siedle Steel product information. In-house telephones which are connected to only one STL - must always be connected to 7.1 to 7.5. If the in-house telephone is connected e.g. at terminal 7.4, at this STL the jumpers + and 7.1 to + and 7.3, + and 7.5 and where available also + and 7 must be taken out. If there are more than 5 call buttons at the STL, these are routed to the add-on call button extension circuit board. 23
24 5 Installation AS-Ta-64/1 Siedle Vario with DoorCom Analog DCA 612- Appliance requirement Remarks TR Analog telephone connection to TBR 21 24
25 AS-Ta-64/1 Siedle Vario with DoorCom Analog DCA 612- Functional Calling and speech between the door station and connected in-house telephones HTS/HTC 811- An existing call cannot be listened in to from other in-house telephones. Door release button for the door release function, light button for the light switching function. Illuminated light button at the door station with potential-free switching contact. Connection of a storey call button (ERT) for calling from an apartment door. Different ring tones for calls from the front door, apartment door and for internal calls. Up to 3 call buttons can be connected at the DoorCom DCA 612- and can call different users of a telephone system. Users are dialled using the dual tone multifrequency dialling method DTMF. Call tones with HTS 811- A call from the door produces a 3 tone call, from the storey door a 2 tone call. Call tones with HTC 811- On a door call, a 3 tone chime sounds, without connection of terminal G a 3 tone call. On a storey call, a 2 tone call sounds. Connection of additional in-house telephones or door stations is possible without switchover device. To ensure tamper-proof connection of the door release, the door release controller CTÖ 602- has to be used. Additional cores are required for this. Supplementary functions Internal speech communication between the in-house telephones HTC 811- and group controller GC 612- is possible. Switching and control functions are possible with the switching/ remote controller SFC 602- A secondary signal unit NS 711- is possible in parallel with an inhouse telephone HTS/HTC 811- A parallel door call to a maximum of 2 HTS/HTC 811- units or NSC 602- /NS 711- is possible simultaneously. Using the group controller GC 612- a parallel call is possible to up to 6 in-house telephones. Remarks a) Line rectifier NG 602- can supply 1 door release and a maximum of 50 call button modules with LED lighting TM 612-1, -2, -3, and -4. With more than 50 illuminated call button modules, an additional TR 603- is required. 12 V AC consumers in the AS plan: Door release appr. 600 ma LED lighting per call button module 20 ma Door release contact load in the door loudspeaker max. 24 V AC, 2 A Light contact load in the door loudspeaker max. 24 V AC, 2 A b) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615- ) c) Conductor length from the in-house telephone to the storey call button ERT max. 50 m/164 ft. The light button in the in-house telephone switches the contact in the door loudspeaker from c to Li for 0.8 seconds, load max. 24 V, 2 A. d) The maximum distance of the DCA 612- to the NG 602- is 20 m. For greater distances, an additional transformer is required for the DCA 612- If several DCA 612- units are used within a system, each DCA 612- must be supplied by its own transformer (TR 603- ). At call button module TM 612- there must not be a connection from the b terminal to another terminal of the door station, except if several TM 612- units are used in a system. Only then may the b terminals be connected to each other. 25
26 5 Installation AS-Ta-64/2 Siedle Vario with 2 door stations Appliance requirement Remarks 26
27 AS-Ta-64/2 Siedle Vario with 2 door stations Functional Calling and speech between the door station and connected in-house telephones HTS/HTC 811- An existing call cannot be listened in to from other in-house telephones. Internal speech communication between the HTC 811-, which is connected to the GC 612- Dialling the user with the call buttons on the telephones. The assignment sequence corresponds to the sequence of call buttons. Door release button for the door release function, light button for the light switching function. Illuminated light button at the door station with potential-free switching contact. Connection of a storey call button (ERT) for calling from an apartment door. Different ring tones for calls from the front door, apartment door and for internal calls. Call tones with HTS 811- A call from the door produces a 3-tone call, from the storey door a 2-tone call. Call tones with HTC 811- On a door call, a 3-tone chime sounds, without connection of terminal G a 3-tone call. A storey call produces a 2-tone call, an internal call a 3-tone call. Connection of additional in-house telephones or door stations possible without switchover device. To ensure tamper-proof connection of the door release, the door release controller CTÖ 602- has to be used. Additional cores are required for this. Supplementary functions Internal speech communication between the in-house telephones HTC 811- and group controller GC 612- is possible. Switching and control functions are possible with the switching/ remote controller SFC 602- A secondary signal unit NS 711- is possible in parallel with an inhouse telephone HTS/HTC 811- A parallel door call to a maximum of 2 HTS/HTC 811- units or NSC 602- /NS 711- is possible simultaneously. Using the group controller GC 612- a parallel call is possible to up to 6 in-house telephones. Remarks a) Line rectifier NG 602 can supply 1 door release and a maximum of 50 call button modules with LED lighting TM 612 1, -2, -3, and -4. With more than 50 illuminated call button modules, an additional TR 603 is required. 12 V AC consumers in the AS plan: Door release appr. 600 ma LED lighting per call button module 20 ma Door release contact load in the door loudspeaker max. 24 V AC, 2 A Light contact load in the door loudspeaker max. 24 V AC, 2 A b) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615 ) The connections shown in dotted lines must be inserted if an in-house telephone is only called from one door station. c) Conductor length from the in-house telephone to the storey call button ERT max. 50 m/164 ft. The light button in the in-house telephone switches the contact in the door loudspeaker from c to Li for 0.8 seconds, load max. 24 V, 2 A. 27
28 5 Installation AS-Ta-64/2 Siedle custom-fit door loudspeaker with 2 door stations Appliance requirement Remarks Siedle Custom-fit door loudspeaker Siedle Custom-fit door loudspeaker 28
29 AS-Ta-64/2 Siedle custom-fit door loudspeaker with 2 door stations Functional Calling and speech between the door station and connected in-house telephones HTS/HTC 811- An existing call cannot be listened in to from other in-house telephones. Internal speech communication between the HTC 811-, which is connected to the GC 612- Dialling the user with the call buttons on the telephones. The assignment sequence corresponds to the sequence of call buttons. Door release button for the door release function, light button for the light switching function. Illuminated light button at the door station with potential-free switching contact. Connection of a storey call button (ERT) for calling from an apartment door. Different ring tones for calls from the front door, apartment door and for internal calls. Call tones with HTS 811- A call from the door produces a 3-tone call, from the storey door a 2-tone call. Call tones with HTC 811- On a door call, a 3-tone chime sounds, without connection of terminal G a 3-tone call. A storey call produces a 2-tone call, an internal call a 3-tone call. Connection of additional in-house telephones or door stations possible without switchover device. To ensure tamper-proof connection of the door release, the door release controller CTÖ 602- has to be used. Additional cores are required for this. Supplementary functions Internal speech communication between the in-house telephones HTC 811- and group controller GC 612- is possible. Switching and control functions are possible with the switching/ remote controller SFC 602- A secondary signal unit NS 711- is possible in parallel with an inhouse telephone HTS/HTC 811- A parallel door call to a maximum of 2 HTS/HTC 811- units or NSC 602- /NS 711- is possible simultaneously. Using the group controller GC 612- a parallel call is possible to up to 6 in-house telephones. Remarks a) The NG is also able to supply the customer's own call buttons. A voltage of 12 V AC max. 1 A is available for the lighting if a door release with an impedance of at least 20 Ohm is used. With a higher current consumption, an additional transformer must be used. 12 V AC consumers in the AS plan: Door release appr. 600 ma Door release contact load in the door loudspeaker max. 24 V AC, 2 A Light contact load in the door loudspeaker max. 24 V AC, 2 A b) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615- The connections shown in dotted lines must be inserted if an in-house telephone is only called from one door station. c) Conductor length from the inhouse telephone to the storey call button ERT max. 50 m/164 ft. The light button in the in-house telephone switches the contact in the door loudspeaker from c to Li for 0.8 seconds, load max. 24 V, 2 A. 29
30 5 Installation AS-Ta-64/3 Siedle Vario with 3 door stations Appliance requirement Remarks 30
31 AS-Ta-64/3 Siedle Vario with 3 door stations Functional Calling and speech between the door station and connected in-house telephones HTS/HTC 811- An existing call cannot be listened in to from other in-house telephones. Internal speech communication between the HTC 811-, which is connected to the GC 612- Dialling the user with the call buttons on the telephones. The assignment sequence corresponds to the sequence of call buttons. Door release button for the door release function, light button for the light switching function. Illuminated light button at the door station with potential-free switching contact. Connection of a storey call button (ERT) for calling from an apartment door. Different ring tones for calls from the front door, apartment door and for internal calls. Call tones with HTS 811- A call from the door produces a 3-tone call, from the storey door a 2-tone call. Call tones with HTC 811- On a door call, a 3-tone chime sounds, without connection of terminal G a 3-tone call. A storey call produces a 2-tone call, an internal call a 3-tone call. Connection of additional in-house telephones or door stations possible without switchover device. To ensure tamper-proof connection of the door release, the door release controller CTÖ 602- has to be used. Additional cores are required for this. Supplementary functions Internal speech communication between the in-house telephones HTC 811- and group controller GC 612- is possible. Switching and control functions are possible with the switching/ remote controller SFC 602- A secondary signal unit NS 711- is possible in parallel with an inhouse telephone HTS/HTC 811- A parallel door call to a maximum of 2 HTS/HTC 811- units or NSC 602- /NS 711- is possible simultaneously. Using the group controller GC 612- a parallel call is possible to up to 6 in-house telephones. Remarks a) Line rectifier NG 602 can supply 1 door release and a maximum of 50 call button modules with LED lighting TM 612 1, -2, -3, and -4. With more than 50 illuminated call button modules, an additional TR 603 is required. 12 V AC consumers in the AS plan: Door release appr. 600 ma LED lighting per call button module 20 ma Door release contact load in the door loudspeaker max. 24 V AC, 2 A Light contact load in the door loudspeaker max. 24 V AC, 2 A b) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615 ) The connections shown in dotted lines must be inserted if an in-house telephone is only called from one door station. c) Conductor length from the in-house telephone to the storey call button ERT max. 50 m/164 ft. The light button in the in-house telephone switches the contact in the door loudspeaker from c to Li for 0.8 seconds, load max. 24 V, 2 A. 31
32 5 Installation AS-Ta-74/1 Siedle Vario, internal speech communication Appliance requirement Remarks 32
33 AS-Ta-74/1 Siedle Vario, internal speech communication Functional Calling and speech between the door station and connected in-house telephones HTC 811- An existing call to the door station cannot be listened in to from other in-house telephones. Internal speech communication between the HTC 811-, which is connected to the GC 612- Dialling the user with the call buttons on the telephones. The assignment sequence corresponds to the sequence of call buttons. Door release button for the door release function, light button for the light switching function. Illuminated light button at the door station with potential-free switching contact. Connection of a storey call button (ERT) for calling from an apartment door. Different ring tones for calls from the front door, apartment door and for internal calls. Call tones with HTS 811- A call from the door produces a 3 tone call, from the storey door a 2 tone call. Call tones with HTC 811- On a door call, a 3 tone chime sounds, without connection of terminal G a 3 tone call. On a storey call, a 2 tone call sounds. Connection of additional in-house telephones or door stations possible without switchover device. To ensure tamper-proof connection of the door release, the door release controller CTÖ 602- has to be used. Additional cores are required for this. Supplementary functions Switching and control functions are possible with the switching/ remote controller SFC 602- A secondary signal unit NS 711- is possible in parallel with an inhouse telephone HTS/HTC 811- A parallel door call to a maximum of 2 HTS/HTC 811- units or NSC 602- /NS 711- is possible simultaneously. Remarks a) Line rectifier NG 602- can supply 1 door release and a maximum of 50 call button modules with LED lighting TM 612-1, -2, -3, and -4. With more than 50 illuminated call button modules, an additional TR 603- is required. 12 V AC consumers in the AS plan: Door release appr. 600 ma LED lighting per call button module 20 ma Door release contact load in the door loudspeaker max. 24 V AC, 2 A Light contact load in the door loudspeaker max. 24 V AC, 2 A The jumpers for the second call button module are indicated in the wiring diagram. b) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615- ) c) Conductor length from the in-house telephone to the storey call button ERT max. 50 m/164 ft. The light button in the in-house telephone switches the contact in the door loudspeaker from c to Li for 0.8 seconds, load max. 24 V, 2 A. f) In the in-house telephones HTC 811- DIL switch 5 must be set to OFF. For more information on the group controller GC 612- see page
34 5 Installation AS-Ta-84/1 Siedle Vario 1 main door station, 1 storey door station Appliance requirement Remarks 34
35 AS-Ta-84/1 Siedle Vario 1 main door station, 1 storey door station Functional Calling and speech between the door station and connected in-house telephones HTS/HTC 811- An existing call cannot be listened in to from other in-house telephones. Door release button for the door release function, light button for the light switching function. Illuminated light button at the door station with potential-free switching contact. Storey door station for the functions calling, speech and door release from one storey door station. Several storey door stations can be connected in parallel. Connection of a storey call button (ERT) for placing calls from an additional door is possible, but not yet indicated in this wiring diagram. Different ring tones for calls from the front door, storey door or for internal calls. Call tones with HTS 811- On a door call/storey call, a 3-tone call sounds. When calling from a storey call button ERT a 2-tone call sounds. Call tones with HTC 811- On a door call, a 3-tone call sounds, on a storey call the 3-tone chime, without connecting terminal G a 3-tone call. When calling from a storey call button ERT a 2-tone call sounds. Connection of additional in-house telephones or door stations possible without switchover device. To ensure tamper-proof connection of the door release, the door release controller CTÖ 602- has to be used. Additional cores are required for this. Supplementary functions Internal speech communication between the in-house telephones HTC 811- and group controller GC 612- is possible. Switching and control functions are possible with the switching/ remote controller SFC 602- A secondary signal unit NS 711- is possible in parallel with an inhouse telephone HTS/HTC 811- A parallel door call to a maximum of 2 HTS/HTC 811- units or NSC 602- /NS 711- is possible simultaneously. Using the group controller GC 612- a parallel call is possible to up to 6 in-house telephones. Remarks a) Line rectifier NG 602 can supply 1 door release and a maximum of 50 call button modules with LED lighting TM 612 1, 2, 3, and 4. With more than 50 illuminated call button modules, an additional TR 603 is required. 12 V AC consumers in the AS plan: Door release appr. 600 ma LED lighting per call button module 20 ma Door release contact load in the door loudspeaker max. 24 V AC, 2 A Light contact load in the door loudspeaker max. 24 V AC, 2 A b) Use door release 12 V AC, at least 20 Ohm (e.g. TÖ 615 ) c) Conductor length from the in-house telephone to the storey call button ERT max. 50 m/164 ft. The light button in the in-house telephone switches the contact in the door loudspeaker from c to Li for 0.8 seconds, load max. 24 V, 2 A. e) If an in-house telephone is only connected to one storey door station, the dotted connection must be made from terminal 11 at the main door loudspeaker to terminal WT of the storey controller ETC 602 In addition, the connection is required from terminal W0 ETC 602 to terminal 11 storey door station. 35
36 5 Installation AS-Ta-85/1 Siedle Vario 1 main door station, 1 storey door station, internal speech communication Appliance requirement Remarks 36
37 AS-Ta-85/1 Siedle Vario 1 main door station, 1 storey door station, internal speech communication Functional Calling and speech between the door station and connected in-house telephones HTS/HTC 811- An existing call cannot be listened in to from other in-house telephones. Internal speech communication between the HTC 811-, which is connected to the GC 612- Dialling the user with the call buttons on the telephones. The assignment sequence corresponds to the sequence of call buttons. Door release button for the door release function, light button for the light switching function. Illuminated light button at the door station with potential-free switching contact. Storey door station for the functions calling, speech and door release from one storey door station. Several storey door stations can be connected in parallel. Connection of a storey call button (ERT) for placing calls from an additional door is possible, but not yet indicated in this wiring diagram. Different ring tones for calls from the front door, apartment door and for internal calls. Call tones with HTS 811- On a door call/storey call, a 3-tone call sounds. When calling from a storey call button ERT a 2-tone call sounds. Call tones with HTC 811- On a door call, a 3-tone call sounds, on a storey call the 3-tone chime, without connecting terminal G a 3-tone call. When calling from a storey call button ERT a 2-tone call sounds. HTC 811- units connected to the GC 612- signal the first two tones of the 3-tone chime on a call from the storey door station, an internal call is signalled by a 3-tone call. Connection of additional in-house telephones or door stations possible without switchover device. To ensure tamper-proof connection of the door release, the door release controller CTÖ 602- has to be used. Additional cores are required for this. Supplementary functions Switching and control functions are possible with the switching/ remote controller SFC 602- A secondary signal unit NS 711- is possible in parallel with an inhouse telephone HTS/HTC 811- A parallel door call to a maximum of 2 HTS/HTC 811- units or NSC 602- /NS 711- is possible simultaneously. Remarks a) Line rectifier NG 602- can supply 1 door release and a maximum of 50 call button modules with LED lighting TM 612-1, -2, -3, and -4. With more than 50 illuminated call button modules, an additional TR 603- is required. 12 V AC consumers in the AS plan: Door release appr. 600 ma LED lighting per call button module 20 ma Door release contact load in the door loudspeaker max. 24 V AC, 2 A Light contact load in the door loudspeaker max. 24 V AC, 2 A b) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615- ) c) Conductor length from the in-house telephone to the storey call button ERT max. 50 m/164 ft. The light button in the in-house telephone switches the contact in the door loudspeaker from c to Li for 0.8 seconds, load max. 24 V, 2 A. e) If an in-house telephone is only connected to one storey door station, the dotted connection must be made from terminal 11 at the main door loudspeaker to terminal WT of the storey controller ETC 602- In addition, the connection is required from terminal W0 ETC 602- to terminal 11 storey door station. f) In the in-house telephones HTC 811- DIL switch 5 must be set to OFF. For more information on the group controller GC 612- see page
38 5 Installation AS-Ta-94/1 Siedle Vario, group switching with internal speech communication Appliance requirement Remarks 38
39 AS-Ta-94/1 Siedle Vario, group switching with internal speech communication Functional Calling and speech between the door station and connected in-house telephones HTS/HTC 811- An existing call cannot be listened in to from other in-house telephones. Internal speech communication between the HTC 811-, which is connected to the GC 612- Dialling the user with the call buttons on the telephones. The assignment sequence corresponds to the sequence of call buttons. Door release button for the door release function, light button for the light switching function. Illuminated light button at the door station with potential-free switching contact. Connection of a storey call button (ERT) for calling from an apartment door. Different ring tones for calls from the front door, apartment door and for internal calls. Call tones with HTS 811- A call from the door produces a 3-tone call, from the storey door a 2-tone call. Call tones with HTC 811- On a door call, a 3-tone chime sounds, without connection of terminal G a 3-tone call. A storey call produces a 2-tone call, an internal call a 3-tone call. Connection of additional in-house telephones or door stations possible without switchover device. To ensure tamper-proof connection of the door release, the door release controller CTÖ 602- has to be used. Additional cores are required for this. Supplementary functions Switching and control functions are possible with the switching/ remote controller SFC 602- A secondary signal unit NS 711- is possible in parallel with an inhouse telephone HTS/HTC 811- A parallel door call to a maximum of 2 HTS/HTC 811- units or NSC 602- /NS 711- is possible simultaneously. Remarks a) Line rectifier NG 602- can supply 1 door release and a maximum of 50 call button modules with LED lighting TM 612-1, -2, -3, and -4. With more than 50 illuminated call button modules, an additional TR 603- is required. 12 V AC consumers in the AS plan: Door release appr. 600 ma LED lighting per call button module 20 ma Door release contact load in the door loudspeaker max. 24 V AC, 2 A Light contact load in the door loudspeaker max. 24 V AC, 2 A The jumpers for the second call button module are indicated in the wiring diagram. b) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615- ) c) Conductor length from the in-house telephone to the storey call button ERT max. 50 m/164 ft. The light button in the in-house telephone switches the contact in the door loudspeaker from c to Li for 0.8 seconds, load max. 24 V, 2 A. f) In the in-house telephones HTC 811- DIL switch 5 must be set to OFF. For more information on the group controller GC 612- see page
40 6 Supplementary functions Group controller GC 612 The group controller GC 612- in the 6-grid housing is used for the connection of a group of max. 6 in-house telephones HTC 811- In-house telephones connected to the group controller the buttons 1 6 can be used to call and communicate with other in-house telephones. The door station is switched off during an internal call. With the GC 612- it is also possible to signal a door call to more than 2 in-house telephones. For this function HTS 811- units can also be used. Several group controllers can be used in an intercom unit. In addition, switching and control functions can be executed from every connected in-house telephone HTC 811- If a door call is made to an in-house telephone which is currently conducting a call, this is interrupted and an engaged signal sounds. After replacing the receiver the door call is signalled. Call differentiation HTC 811- Main door call: 3-tone chime, storey door call: 1st and 2nd chime tone of the three-tone chime, subsequently normal 3-tone chime Internal call: 3-tone call Storey call: 2-tone call (ERT button connected directly at the HTC) Door parallel call The door call can be signalled simultaneously in conventional systems at up to 2 in-house telephones. With the GC 612- it is possible to signal a door call at up to 6 in-house telephones. This always actuates two in-house telephones simultaneously. With more than two parallel telephones, these are always called in pairs with a time offset. Speech connection For each group controller, only one call can be held. If an internal call already exists within a group, it is possible to place an additional call from the door loudspeaker only to another in-house telephone which is not directly connected to the GC 612- The group controller acts in relation to the 1+n side circuit installation in the same way as an in-house telephone. Each GC 612- requires the NG 602- for its own power supply. Switching and control functions Switching and control functions are possible in conjunction with the SFC 602 A maximum of 6 control functions can be actuated from each HTC 811 in the group. Control functions can be executed at any time with the receiver down or during an existing speech connection. Settings at DIL switch 2 may be necessary in the in-house telephones HTC 811 Operating elements GC 612- : One programming switch in order to enable the programming mode One status LED to display the programming mode and saving. 8 DIL switches to determine the required functions/for programming. DIL switches 1 6 for assignment of the door call to the in-house telephones 1 to 6 DIL switch 7 ON OFF SFC 602- is connected at the group controller SFC 602- is connected at the door loudspeaker If DIL switch 7 is set to OFF, DIL switch 8 is non functional. DIL switch 8 ON Control functions 5 and 6 act on the SFC 602- at the door loudspeaker OFF Control functions 5 and 6 act on the SFC 602- at the group controller Internal call From each HTC 811- unit in the group, each other in-house telephone of the same group can be called. The following procedure has to be observed here: Pick up the receiver and only then actuate the required call button at the in-house telephone. Secondary signal unit For door call 1 (terminal 7.1) a potential-free contact S1/S2 is available at the GC 612 (max. 24 V, 2 A). Installation The in-house telephones at the GC 612- are installed in star formation. Maximum conductor lengths between: GC 612- and telephones 100 m/328 ft. GC 612- and door station 500 m/1640 ft. Wiring diagram without video AS-Ta-74/1 on page 32 As-delivered status of the GC 612- The door call inputs are assigned to telephones 1:1. Terminal 7.1 (input 1) is assigned to the 1st telephone, terminal 7.6 (input 6) to the 6th telephone. 40
41 Application Assignment of door call inputs to in-house telephones 1 6. Activate the programming mode at the GC 612-, the status LED starts to flash. When reprogramming door calls, the same applies to new programming, i.e. the existing programming is overwritten. Select the relevant telephone using the DIL switch e.g. telephone 1 (DIL 1 ON). Several DIL switches can be used. 3 Sek. Hold down the call button you wish to assign to one or more in-house telephones for 3 seconds. (e.g. door call 1 to telephone 1). Select the telephones (e.g. telephone 3 and 4) you wish to assign to the next door call. 3 Sek. The call button you wish to assign to the telephone should be held down for 3 seconds (e.g. door call 2 to telephones 3 and 4). Program other call inputs using the same procedure. Once all the telephones have been assigned, terminate the programming mode. Press the programming mode button to terminate the programming session. 41
42 6 Supplementary functions Switching/remote controller SFC 602- The switching/remote controller in a 3-grid housing is used to execute a maximum åof 4 central switching and control functions (connection to the door loudspeaker) or 4 local switching and control functions (connection to group controller). Actuation can take place via the door release or light button and also using keys 1 6 from in-house telephones HTC 811- Functions of the SFC relay with potential-free changeover contact and 3 relays with one potential-free working contact each. The 4 relays can be individually set as switches or buttons. Setting 6 DIL switches for setting the functions and for relay assignment to the buttons in the in-house telephones. 1 rotary switch for setting the switching time, when relays 1 and 2 are used as timers. The time can be set in 10 steps of 3 seconds each up to 20 minutes. If relays 3 and 4 are set as timers, the time is fixed at 3 seconds. Installation Connection of the SFC 602- takes place via terminals D+ and D at a door loudspeaker module TLM 612- /TLE 061- When connecting to a controller GC 612- or ETC 602- only the telephones connected to the controller can initiate switching and control functions. When connecting to a door loudspeaker, the functions are possible from all connected telephones. In a 1+n system a maximum of 2 SFC 602- or 2 CTÖ 602- units can be connected per door loudspeaker. A mixture of SFC 602- and CTÖ 602- units is possible. Specifications Operating voltage: 12 V AC Operating current: max. 250 ma Contact type: 1 changeover switch 24 V DC/AC, 2 A; 3 n.o. contacts 24 V DC/AC, 2 A Switching time: 2 x adjustable from 3 sec to 20 min and 2 x fixed at 3 sec Horizontal pitch (HP): 3 Dimensions (mm) W x H x D: 53.5 x 89 x 60 Position of the DIL switches Function assignment for relays 1 4 DIL switch Position Function Relay Remark 1, 2 OFF/OFF Button for 1, 2 Time for both adjustable from 3 seconds to 20 minutes 3, 4 OFF/OFF Button for 3, 4 Time for both fixed at 3 seconds 1-4 ON Switch 1-4 ON/OFF switch If the light (Li) and door release (Dr) button are used in the in-house telephone for actuation of the relays in the SFC 602-, the DIL switches 2 and 4 should be set to OFF to ensure that the timer function is activated! Button assignment in the HTC 811- DIL switch Position Relay Actuation by button A, B OFF/OFF 1, 2, 3, 4 1, 2, 3, 4 A, B ON/OFF 1, 2, 3, 4 3, 4, 5, 6 A, B OFF/ON 1, 2, 3, 4 1, Li, 2, Dr A, B ON/ON 1, 2, 3, 4 5, Li, 6, Dr 42
43 Appliance requirement Remarks Connection of an SFC 602 in the circuit AS Ta/64 1. All connected in-house telephones can initiate switching functions of the SFC
44 6 Supplementary functions Storey controller ETC 602 The storey controller in the 6 grid housing is used to connect a storey door station. Up to a maximum of 7 storey door stations can be connected to a storey controller. In addition to a call with the main door station in the side circuit, a call is also possible from a storey door station to an in-house telephone. If a call exists from a storey door station, it is not possible to place a call to any of the other in-house telephones connected to the ETC 602 If you wish as many simultaneous calls to be possible as there are storey door loudspeakers, for each storey door loudspeaker 1 ETC 602 with an NG 602 is required. In addition, a call can be held from a main (side circuit) door loudspeaker to a free storey, i.e. several calls are possible simultaneously. If you require an additional internal speech facility between the connected in-house telephones at the storey controller, a group controller GC 612 and in-house telephones HTC 811 (max. 6) must be used in addition. In parallel with every ETC 602 it is possible to connect a switching/remote controller SFC 602 to the storey door loudspeaker(s). All calls have audio privacy. When using the HTS 811 no call differentiation between the main (side circuit) door loudspeaker and storey door loudspeaker is possible! Call differentiation HTC 811- at ETC 602- Main (side circuit) door call: 3-tone call Storey door call: 3-tone chime Call differentiation HTC 811- at ETC 602- with GC 612- Main door call: 3-tone chime Storey door call: 1st and 2nd chime tone of the three-tone chime, subsequently normal 3-tone chime Internal call: 3-tone call Function After a completed call from a storey door station, this remains switched on at the called in-house telephone for 30 seconds. If no receiver is lifted during this period, the connected in-house telephones on the storey level are switched on again at the main door station. Actuation of the storey door release, the storey light and the storey SFC 602- is only possible during a connection to the storey. After replacing the receiver, the telephones are switched on again at the main door loudspeaker(s) after around 10 seconds. Outside a storey call, the door release and light relay of the last called main (side circuit) door loudspeaker and any connected SFC/CTÖ 602 are always actuated. The storey controller ETC 602 is fitted with a potentialfree switchover contact (WT/W0/ WE). 44
45 6 Supplementary functions Secondary signal controller NSC 602- Using the secondary signal controller NSC 602- an additional secondary signal unit or a radio chime can be actuated in parallel with the door and storey call. There are 2 potential-free work contacts available for this purpose which have a common reference point. The NSC 602- can be mounted/inserted in a size 55 switch box under the telephone or offset in a junction box. Door call Storey call The secondary signal controller behaves in the same way as an inhouse telephone connected in parallel, i.e. it is not possible to connect an additional telephone in parallel. Specifications Contact type: changeover contact max. 24 V, 2 A Protection system: IP 20 Dimensions (mm) dia. x H: 51 x 23 Appliance requirement Remarks 45
46 6 Supplementary functions Controller door release CTÖ 602 The controller door release CTÖ 602- is used to actuate a door release from the subdistributor. This installation is used if the connecting wires are not connected in the housing of the door station for safety reasons. Connection of the CTÖ 602- takes place at junctions D+/D- of the Siedle door loudspeaker TLM 612- or TLE 061- For selective actuation of the door release, one CTÖ 602- is required per door loudspeaker. Specifications Operating voltage: 12 V AC Operating current: max. 70 ma Contact type: n.o. contacts max. 24 V, 2 A Switching time: Fixed at 3 sec Protection system: IP 20 Ambient temperature: 0 C to +40 C Horizontal pitch (HP): 3 Dimensions (mm) W x H x D: 53.5 x 89 x 60 AS-Ta-64/1 with CTÖ 602- Appliance requirement Remarks 46
47 AS-Ta-64/2 with CTÖ 602- Both door releases have a tamperproof connection. The mode of operation and functional characteristics are identical to AS-Ta-64/2 on page 28. Appliance requirement Remarks 47
48 6 Supplementary functions Parallel switching in-house telephones Parallel switching HTS/ HTC 811- Using 1+n technology, a maximum of 2 in-house telephones can be operated in parallel. Accessories NSC 602 and NS 711 also count as parallel devices. Via a GC 612 it is possible to call up to 6 in-house telephones in parallel. The GC 612 must be programmed accordingly for this function. The range is reduced in the event that two in-house telephones are switched in parallel: HTS 811 HTC m/820 ft 250 m/820 ft Secondary signal unit NS 711- Instead of a second in-house telephone it is also possible to operate a secondary signal unit NS 711 in parallel. The NS 711 signals a door and storey call with call differentiation. When connecting terminal G the door call is signalled as a three-tone chime. Applicable for all circuit diagrams Conductor length from the in-house telephone to the storey call button ERT max. 50 m/164 ft. 48
49 6 Supplementary functions Pilfer safeguard DSC 602- Pilfer safeguard for Vario modules Bistable magnet for integration in mounting frame MR 611- Application To secure valuable modules such as camera modules, code lock modules or to ensure tamper-proof operation of the door release. A stable metal plate locks the opening mechanism and prevents modules from being removed. The magnets are opened and locked in the sub-distributor at pilfer safeguard controller DSC 602- A maximum of 2 ZDS 601- units can be operated at one DSC 602- Range Maximum conductor length between DSC 602- and ZDS 601- with 0.8 mm core diameter 100 m/328 ft. With Siedle-Steel, the pilfer safeguard controller SDSC is required. 49
50 6 Supplementary functions Staircase light/outside light Light actuation Using the light button in in-house telephones HTS/ HTC 811- the light contact is closed in the door loudspeaker for 0.8 seconds. The reference for this contact is terminal c. Pick-up at terminal Li. Following completion of the installation, this function is active without any further programming. To actuate the staircase and/or outside light, in accordance with the VDE regulations a light current or time relay (e.g. ZR 502- ) must be interconnected. In additional, it is possible to switch the outside or inside light with the light button in the door loudspeaker module. Pick-up of the button takes place at terminals T1 and T2 at the door loudspeaker module. 50
51 6 Supplementary functions LED actuation, potential-free buttons LEDs The in-house telephones HTC 811- are equipped with two LEDs. The LEDs are located under the buttons 3 and 4, actuation can take place using direct or alternating voltage. La1 and La2: V AC, max. 10 ma La1 and La2: 15 V DC, max. 10 ma, observe polarity Application Open garage door Open front door Error message Buttons In the as-delivered status, buttons 5 and 6 transmit the information directly via cores 1 and 7. Using switch block DIL2 in the in-house telephones HTC 811-, buttons 5 and/or 6 can be switched to potential-free. The max. button load is 15 V AC, 30 V DC, 2 A in each case. Application Additional door release Garage door open/shut Actuation of current surge relay 51
52 7 Servicing Exchange/extension The in-house telephones HTS/ HTC 811 can be used in existing 1+n systems with the predecessor models HTS/HTC 711 Exchange of HTS/HTC 711 units for HTS/ HTC 811 units is possible. The terminal designations of the inhouse telephones are identical. The HTC 811- deviates from the HTC 711 in as far as the light button can optionally be used as button 1. Switchover takes place via a DIL switch in the in-house telephone HTC 811 entfällt Comparison HTC 811- /HTC
53 53
54 7 Servicing Measured values Measured values in the 1+n system, for measurement using a digital multimeter Idle status Voltage door station Voltage in-house telephone Description Terminal 1 and 7 Terminal 1 and V DC 0 V DC No in-house telephone connected, core interrupted, in-house telephone defective V DC V DC, 50 µa OK In-house telephone is in the idle status V DC V DC, 50 µa V DC, >10 ma Terminal + at call button module or diode accessory missing In-house telephone has already been called and is active <14 V DC <14 V DC Cores to in-house telephone under load or connected to an external device Call status Voltage door station Voltage in-house telephone Description Terminal 1 and 7 Terminal 1 and V DC, 150 ma >18 V DC, max. 150 ma OK 24 V DC --- No in-house telephone connected <8 V DC 0 V Short circuit between terminal 1 and 7 In-house telephone active/speech operation Voltage door station Terminal 1 and 7 Voltage in-house telephone Terminal 1 and 7 Description V DC --- No in-house telephone connected V DC V DC, 50 µa V DC, 50 µa In-house telephone has not been called from the door Last door call longer than 30 seconds ago V DC V DC, >10 15 ma OK, receiver not lifted within 30 seconds after call V DC V DC, >20 ma OK, speech connection exists <14 V DC <14 V DC Cores to in-house telephone under load or connected to an external device Intercom system with more than 1 door station Voltage door station terminal TLn and appr. 6 V DC Description OK Connection to SFC 602- or CTÖ 602- Voltage door station D+ and D Voltage SFC/CTÖ Terminal D+ and D Description appr. 14 V DC appr. 14 V DC Connecting cores D+/D- OK appr. 14 V DC appr. 14 V DC SFC/CTÖ not responding, D+/D cores interchanged appr. 14 V DC 0 V SFC/CTÖ not responding, D+/D cores interrupted 0 V 0 V SFC/CTÖ not responding, D+/D cores short circuited 54
55 Glossary Index Classic CL 9, 20 Comparison 52 Conductor length 4 Control functions 11, 42, 51 Diode accessory 8 Door loudspeaker 8-9, Door release 6 DoorCom Analog 12, 24 ERT 6 Exchange 52 Group controller 10, 32 Internal call 32 Internal speech 32 LED actuation 51 LED display 51 Light button 6 Measured values 54 Outside light 50 Parallel switching 48 Potential-free buttons 51 Range 4, 49 Secondary signal controller 6, 11, 45 Secondary signal unit 6, 13, 48 Servicing 52 Steel 9, 22 Storey call 6 Storey controller 11, 34 Switching/remote controller 6, 11, 42 Terminal block Time light contact 6 Troubleshooting 54 CL A xx N 9, 20 CTÖ , 46 DCA , 24 DSC ETC , 34 GC , 32 HTC HTC HTS HTS NG NS , 48 NSC , 45 SFC , 42 Steel STL 9, 22 TLE 061-8, 18 TLM 612-8, 16 TM 612-8, 16 TR ZD ZDS ZR , 50 ZTC ZTS The latest issue of the 1+n System Manual is located in the download area on the Siedle website 55
56 S. Siedle & Söhne Telefon- und Telegrafenwerke OHG Postfach Furtwangen Bregstraße Furtwangen 2006/02.15 Printed in Germany Best. Nr / EN Telefon Telefax [email protected]
System Manual 1+n technology
System Manual 1+n technology Contents 1 1+n technology System description 3 2 Safety remarks 3 3 Configuration, conductor lengths 1+n system without video 4-5 1+n system with video 6-7 Overview 8 4 Device
User guide. MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG
User guide MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG Doorstation with telephone line interface for the connection to telephone systems Version with 1 bell button Page 1 Contents Description...3
Manual DoorCom IP DCIP 650-0
Manual DoorCom IP DCIP 650-0 Contents 1 System description 3 2 Safety remarks 3 System requirements 3 3 Structure DCIP 650-... 4 DCIP 650-... with DCA 740-... 5 Terms 6 4 Components DoorCom IP Door loudspeakers,
PS 29M DUAL CHANNEL BELTPACK IN METAL CASE
PS 29M DUAL CHANNEL BELTPACK IN METAL CASE USER MANUAL October 2013 This product is designed and manufactured by: ASL Intercom BV Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:
How To Use A Germany Germanysa Germaniesa Gmbo.Com Gmbos System 2.2.2 (A/S) With A Power Supply And Power Supply For A Power Source (Power Supply)
System Manual Access Issue 2011 Contents System description Safety remarks 3 System structure, conductor material and range Door area 4 Network LAN 5 Cabling for indoor devices 6 System components Overview
BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.
BIBUS VOP Advice for use: large blocks of flats with switchboard and mixed mainly audio systems Ideal for door phone systems with up to 250 users VOP technology Easy creation of mixed audio and video door
Getting connected. Door communication and access control in the IP network
Getting connected Door communication and access control in the IP network 3 Door communication and access control in the IP network Siedle links IP networks with building communication and access control.
SECTION 3A (Rev.F) SECTION CONTENTS. Download from www.urmet.com Technical Manuals area. sec.3a INSTALLATION...9 TECHNICAL SPECIFICATIONS...
SECTION 3A (Rev.F) Apartment door phone stations Download from www.urmet.com Technical Manuals area. ATLANTICO DOOR PHONES 2 TECHNICAL SPECIFICATIONS...2 4+n wire system door phones...2 Door phone with
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
accessories and TechnoloGy Behnke electronics sip view inside a Behnke sip intercom Technology
accessories and TechnoloGy Behnke electronics sip view inside a Behnke sip intercom 5 6 2 3 8 5 4 7 1 9 1 Module housing Fixing the modules in the front frame and holder for electronics housing 3 4 2 configuration
Operating Instructions. Keypad 2605..
Operating Instructions Keypad 605.. Contents Device description...4 Device presentation...5 Areas of application...6 Operation...8 Acknowledgement signals... 10 Start-up sequence... 11 Connection terminals...1
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Memcom Emergency Telephone
Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming
Art.275 PABX Interface
Art.275 PABX Interface TECHNICAL MANUAL EDITION 1.0 DESCRIPTION The Art.275 interface enables a Videx intercom panel to be connected to an analogue extension port of a telephone switchboard (PABX). The
Model PBX 308 Plus System Administration Guide
Model PBX 308 Plus System Administration Guide Introduction 3 Installation Hints 4 System Programming 5 IMPORTANT Exchange Lines 6 Assign Incoming calls to ring Nominated Extensions 7 Cascade Ringing Of
LOXONE 12 Channel Amplifier
LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room
Model PBX 416 Plus System Administration Guide
Model PBX 416 Plus System Administration Guide Introduction 4 Installation Hints 4 System Programming 5 - System Password 5 - Changing Password 5 - Entering password in Direct 5 Dial Mode Exchange Line
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring
BASIC DIAGRAMS FOR 4+N WIRE DOOR PHONE SYSTEMS
SECTION A (REV.D) DOOR PHONE SYSTEMS BASIC DIAGRAMS FOR 4N WIRE DOOR PHONE SYSTEMS Download from: www.urmetdomus.com Technical Manuals area sec.a DOOR PHONE SYSTEMS FUNCTION CONNECTION OF UP TO DOOR PHONES
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke
1 All safety instructions, warnings and operating instructions must be read first.
ONYX USER MANUAL 2 Dateq ONYX Manual Safety instructions EN Safety instructions 1 All safety instructions, warnings and operating instructions must be read first. 2 All warnings on the equipment must be
Operating Instructions. Telephone System tiptel 1/8 fax clip tiptel 2/8 clip. (Release 2) tiptel
Operating Instructions (UK) Telephone System tiptel 1/8 fax clip tiptel 2/8 clip (Release 2) tiptel Table of Contents Connection of 8 extensions..........3 Connection of 7 extensions and 1 door intercom................4
Baudisch.DoorController
VoIP and SIP for analog door stations. Implementation of the analog signals of existing intercoms on Ethernet Connection of several call buttons Switching output for door opener and light Use of existing
TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual
TELIKOU Intercom System MS-500(4+1 channel) Main Station Instruction Manual TELIKOU Systems All Rights Reserved While TELIKOU makes every attempt to maintain the accuracy of the information contained in
TS-770 SERIES CONFERENCE SYSTEM
TS-770 SERIES CONFERENCE SYSTEM TOA Conference System with easy installation, use and expansion, plus remote participation capability Compact, high-performance conference system with clear sound and remote
AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS
AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS 1 DORANI VIDEO INTERCOM - 2 WIRE SERIES 7 TFT MONITOR TECHNICAL SPECIFICATIONS 7 Colour TFT screen 480 x
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
Model PBX 308 System Administration Guide
Model PBX 308 System Administration Guide Introduction 4 Installation Hints 4 Wall Mounting System Programming 5 System Password Changing the Password IMPORTANT Exchange Lines 6 1 Exchange Line connected:
Innovative DOOR STATION Solutions
Innovative DOOR STATION Solutions When a visitor arrives at your front door or gate we ring... Your mobile when you are out Your normal telephones in your home Your PABX system in your office Communicating
Model PBX 308 Plus System Administration Guide
Model PBX 308 Plus System Administration Guide Introduction 4 Installation Hints 4 System Programming 5 - System Password 5 - Changing Password 5 Exchange Line Set up 6 - Caller Display 6 - Setting Date
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Model PBX 416+ Programming & User Guide
Model PBX 416+ Programming & User Guide 1 Introduction... 5 Installation hints... 5 Wall mounting... 5 System programming... 6 System password... 6 Changing the password... 6 Exchange line set up... 6
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
TS510 & TS500. Installation & User Guide. Compatible Equipment
Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction
1.1 The Audio Entry Phone System shall be suitable for 2 way voice communication between the different apartments and the main entrance panel.
DIGITAL AUDIO INTERCOM SYSTEM The contractor shall Supply, Install, Test and Commission a modern Audio Entry Phone System to facilitate Audio Communication between the different apartments and the building
TX GSM SMS Auto-dial Alarm System. Installation and User Manual
TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses
An intercom completes any access control system by providing a means for the user of screening visitors before granting access, thereby significantly
INTERCOM SYSTEMS An completes any access control system by providing a means for the user of screening visitors before granting access, thereby significantly increasing security. traffic barriers POLOphone
TELIKOU Intercom System. TM-200 Main Station. Instruction Manual
Intercom System TM-200 Main Station Instruction Manual TELIKOU Systems All Rights Reserved I. Introduction Thank you for choosing TELIKOU intercom product. TM-200 main station is suitable for television
Enterphone Solo. User/Installation Manual Part No. 421-2001
Enterphone Solo User/Installation Manual Viscount Communication and Control Systems Inc. 4585 Tillicum Street, Burnaby, B.C., Canada V5J 5K9 Phone: (604) 327-9446 Toll Free: 1-800-476-3774 Fax: (604) 327-3859
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
Monitors. Platea Monitor
Monitors Platea Monitor The common features of Platea monitors are: Casing manufactured in ABS RAL9003 white colour. 4" b/w flat tube screen or color TFT LCD of 'A Grade' quality. Brightness and contrast
USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.
USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487
Mounting and operating instructions. Surface-mounted hands-free feature home station 1250..
Mounting and operating instructions Surface-mounted hands-free feature home station 1250.. Device description The surface-mounted hands-free feature home station is a prefabricated unit and is part of
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
4000 Series audio door entry system (using 9307.1 power supply) Installation Instructions IN9307.1
Unit, AM Business Park umberland Avenue Park Royal, London, NW 7QL t : f : w : www.doorentrydirect.com 4 Series audio door entry system (using 7. power supply) Installation Instructions IN7. 7 Getting
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Vitosoft 200 Vitodata 300 Vitocom 300 Vitocom 100
Contents Page 1, type FA1 1.1 Function description................................................................................... 6 1.2 Pre requisites.............................................................................................
Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions
Disabled Toilet Alarm Installation & Operating Contractor Pack Installation & Operating Instructions 1 Overview The Channel Safety Systems Disabled Toilet alarm contractor Packs are an efficient way of
Dialog 4220 Lite/Dialog 4222 Office
Dialog 4220 Lite/Dialog 4222 Office System telephones for MD110 Communication System User Guide Flinders University Table of Contents Description 2 Incoming Calls... 10 Outgoing Calls... 12 During Calls
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
3x cinch/s-video socket Order no.: 33 1532 xx. USB/3.5 mm audio socket Order no.: 33 1539 xx. VGA socket Order no.: 33 1540 xx
3x cinch/s-video socket Order no.: 33 1532 xx USB/3.5 mm audio socket Order no.: 33 1539 xx VGA socket Order no.: 33 1540 xx VGA socket with screw-in lift terminals Order no.: 33 1541 xx High definition
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
AlarmSense 2-wire detection and alarm system. Product Guide
AlarmSense 2-wire detection and alarm system Product Guide Contents What is AlarmSense? 2 The purpose of AlarmSense 4 How AlarmSense works 4 Alarmsense Features 5 Detector removal monitoring 5 Priority/non-priority
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
D45. SySTEm. ThE high-performance
D45 ThE high-performance SySTEm Security monitoring system with digital BUS technologies High efficiency system and quick installation for both backbone and riserdevicesthankstotheuse of cat.5e UTP cables
Link SIP Door Phone. Manual V1.0. Linkcom France. 1 11 rue du Soleil Levant 92140 CLAMART Copyright 2008 Linkcom Tous droit réservés
Link SIP Door Phone Manual V1.0 1 Table of Contents 1. BASIC DESCRIPTION...3 1.1. FEATURES... 3 1.2. MODULE ASSEMBLY... 3 2. MODULE FEATURES...4 2.1. BASIC MODULE... 4 2.2. RELAYS CONNECTION... 4 2.3.
AUTODIALLER / QUICKDIALLER - SA132
AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide
Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT Active Speaker System with remote input LX523 User Manual & Installation Guide AUDAC PROFESSIONAL AUDIO EQUIPMENT User Manual & Installation
System Administration Guide. Model KS 832. Expandable up to 1664
System Administration Guide Model KS 832 Expandable up to 1664 Introduction 4 Installation Hints 4 System Programming 5 - System Password 5 - Changing Password 5 Exchange Line Set up 6 - Caller Display
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
SECTION 16760 - PLANT INTERCOMMUNICATION SYSTEM. City of San Diego, CWP Guidelines
PART 1 - GENERAL SECTION 16760-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing plant intercommunication systems with power supplies, signal amplifiers,
CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access
CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance
ELAN AUDIO. Operational Description. News Work Station NWS-01
ELAN AUDIO 2 STEEL COURT SOUTH GUILDFORD WA 6055 PHONE (08) 9277 3500 FAX (08) 9478 2266 email [email protected] web www.elan.com.au Operational Description. News Work Station NWS-01 The NWS-01 News
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
Heating Controller. Building Technologies HVAC Products
2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or
Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
mecotron Safety relay ESTOP-2 For emergency stop monitoring
E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated
Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128
Dallas Delta Corporation Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128 Email: [email protected] www.dallasdelta.com.au LP GUARD DOORSTATION MK II G UARD Doorstation
User Manual. Please read this manual carefully before using the Phoenix Octopus
User Manual Please read this manual carefully before using the Phoenix Octopus For additional help and updates, refer to our website To contact Phoenix Audio for support, please send a detailed e-mail
PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS
PT-6000 Power Tower INSTALLATION MANUAL 10.5 9.75 12 22.75 10.75 MAXIMUM SOIL HEIGHT: DO NOT ALLOW FILL TO EXCEED THIS LEVEL! 11.5 4 4 13 Optional PT-BASE for new installations or when previous 2000/6000
TCR easy Plus Alarm. Operating Instructions
TCR easy Plus Alarm Operating Instructions Table of Contents General.....................................4 Installation...................................5 Putting into Operation............................5
video door entry system offer
video door entry system offer CATALOGUE 2013 BTICINO Specialists in Video Door Entry Systems BTicino, introduces a complete range of products and systems capable of meeting all application and building
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
Current and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
PagePac Door Phone Controller V-5324001 Installation and Operation Manual
PagePac by ISSUE 1 PagePac Door Phone Controller V-5324001 Installation and Operation Manual 947177 Contents 1 Introduction 1-1 Using This Manual 1-2 The PagePac Door Phone Controller 1-3 Features 1-3
Technical Description. Multifunctional Desk-Top Call Station Digital Version 8, 16 Keys L.No. 1 760 4, 1 761 5
Technical Description Multifunctional Desk-Top Call Station Digital Version 8, 16 Keys L.No. 1 760 4, 1 761 5 Contents 1. General remarks 2. Design 3. Block diagram 4. Function 4.1 Controller system with
VIDEO DOOR PHONE SYSTEM
ENGLISH VIDEO DOOR PHONE SYSTEM USER MANUAL Manual covers IH-692 Master and IH-692 Slave Monitors PRECAUTIONS BEFORE INSTALLATION Connect this unit ONLY to other compatible units. Do not connect it to
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
Door Phone VoIP. User manual IPDPS 01C IPDPS 02C IPDPS 01 IPDPS 02
ALPHATECH TECHNOLOGIES s.r.o. Jeremenkova 88, Praha 4, Czech Republic www.alphatechtechnologies.cz Door Phone VoIP IPDPS 01C IPDPS 02C IPDPS 01 IPDPS 02 User manual Welcome We congratulate you on purchase
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
DIGITAL TELEPHONE INTERFACE REF. R3615
DIGITAL TELEPHONE INTERFACE REF. R3615 INSTALLATION GUIDE *G503180E* INDEX: 1. INTRODUCTION...3 2. DESCRIPTION OF THE DIGITAL TELEPHONE INTERFACE....4 2.1 Parts of the Digital Telephone Interface...4 2.2
AT&T. PARTNER Plus Door Phone. Installation and Operation Manual
AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
ZMR 80 STEREO MODULAR ZONER USERS MANUAL
ZMR 80 STEREO MODULAR ZONER USERS MANUAL Lime Technologies http://limetechnologies.co.uk Tel: 08712 233127 ZMR80 Stereo Modular Zoner Mixer Introduction The modular construction of the ZMR80 allows it
INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY
SECTION F (REV.B) INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY Download from: www.urmetdomus.com Technical Manuals area BASIC SYSTEM DIAGRAMS
Analog Door Phone Model LUADS MAT Code #408466555
Analog Door Phone Model LUADS MAT Code #408466555 Installation and Use Manual Telephone line powered Two-way, hands-free communication Vandal-resistant brushed stainless steel faceplate with mounting gasket
2 WIRE video door entry system
J J N P CLASSE 00 VE WIRE video door entry system 5 Description Front view WIRE handsfree colour video handset with inductive loop, preset for different types of installations, depending on the accessories
2013 Wireless Video Intercom INSTALLATION GUIDE
2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door
TCB-2 Auto Answer Coupler Product Manual
TCB-2 Auto Answer Coupler Product Manual About Comrex Comrex has been building reliable, high quality broadcast equipment since 1961. Our products are used daily in every part of the world by networks,