13 SERIES. Electronic step relays A
|
|
- Berniece Douglas
- 4 years ago
- Views:
Transcription
1 13 Electronic step relays A Electronic step relay - Rail mount - 1 Pole Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function selectable (13.91) Use with 3 or 4 wire connection, with automatic recognition by the relay Control input can be continuously applied Longer mechanical and electrical life, and much quieter than electromechanical step relays Zero crossing load switching Can be mounted behind blanking plates, as widely used in residential wiring systems such as; BTicino: Axolute, Matix, Living and Magic, Gewiss: GW24, Vimar: Plana and Idea (13.91) (13.81) Cadmium free contact material 13.81/91 Screw terminals NO (SPST-NO) 17.5 mm wide 1 NO (SPST-NO) Step relay and timing step relay (10 minutes) For mounting within residential switch boxes For outline drawing see page 10 Contact specification Contact configuration 1 NO (SPST-NO) 1 NO (SPST-NO) Rated current/maximum peak current A 16/30 (120-5 ms) 10/20 (80-5 ms) Rated voltage/ Maximum switching voltage V AC 230/ 230/ Rated load AC1 VA Rated load AC15 (230 V AC) VA Nominal lamp rating: 230 V incandescent/halogen W fluorescent tubes with electronic ballast W fluorescent tubes with electromechanical ballast W CFL W V LED W LV halogen or LED with electronic ballast W LV halogen or LED with electromechanical ballast W Minimum switching load mw (V/mA) 1000 (10/10) 1000 (10/10) Standard contact material AgSnO 2 AgSnO 2 Supply specification Nominal voltage (U N ) V AC (50/60 Hz) V DC Rated power V A (50 Hz)/W 3/1.2 2/1 Operating range AC (50 Hz) ( )U N ( )U N DC Technical data Electrical life at rated load in AC1 cycles Maximum impulse duration continuous continuous Dielectric strength between: open contacts V AC supply - contacts V AC Ambient temperature range C Protection category IP 20 IP 20 Approvals (according to type) 1
2 13 13 Electronic step/monostable relays 16 A Electronic step/monostable relay Rail mount - 1 Pole Multifunction step/monostable relay with reset command - Rail mount 1 Pole Selectable Step or Monostable operation (13.01) Multifunction (Step, Timing step, Monostable, Light ON) (13.61) Reset feature, for centralized off command (13.61) Set feature, for centralized on command ( ) Control input can be continuously applied Longer mechanical and electrical life, and much quieter than electromechanical step relays V AC/DC and V AC supply versions (13.61) Suitable for SELV applications and available also for supply 12 and 24 V AC/DC (13.01) Zero-crossing load switching (13.61) Cadmium free contact material 13.01/61 Screw terminals CO (SPDT) Step or monostable relay 35 mm wide 1 CO (SPDT) Reset feature, for centralized off command Set feature, for centralized on command Multifunction: - step relay - timing step relay - monostable relay - light on 17.5 mm wide 1 NO (SPST-NO) Reset feature, for centralized off command Multifunction: - step relay - timing step relay - monostable relay - light on 17.5 mm wide For outline drawing see page 10 Contact specification Contact configuration 1 CO (SPDT) 1 CO 1 NO Rated current/maximum peak current A 16/30 (120 A - 5 ms) 16/30 (120 A - 5 ms) 16/30 (120 A - 5 ms) Rated voltage/ Maximum switching voltage V AC 250/ / /400 Rated load AC1 VA Rated load AC15 (230 V AC) VA Nominal lamp rating: 230 V incandescent/halogen W fluorescent tubes with electronic ballast W fluorescent tubes with electromechanical ballast W CFL W V LED W LV halogen or LED with electronic ballast W LV halogen or LED with electromechanical ballast W Minimum switching load mw (V/mA) 1000 (10/10) 1000 (10/10) 1000 (10/10) Standard contact material AgSnO 2 AgSnO 2 AgSnO 2 Supply specification Nominal voltage (U N ) V AC (50/60 Hz) V DC/AC (50/60 Hz) Rated power AC/DC V A (50/60 Hz)/W 2.5/2.5 1/ /1 Operating range V AC (50 Hz) V DC/AC (50 Hz) Technical data Electrical life at rated load in AC1 cycles Maximum impulse duration continuous continuous continuous Dielectric strength between: open contacts V AC supply - contacts V AC Ambient temperature range C Protection category IP 20 IP 20 IP 20 Approvals (according to type) 2
3 13 Electronic call/reset relays and monostable relays 8-12 A Call & Reset Relay - Rail mount - 1 Pole Call & Reset Relay - Rail mount - 2 Pole Electromechanical monostable relay Switch box mount - 1 Pole Call relay with reset command suitable for residential and commercial applications: public bathroom, hospital, hotel (type 13.11/13.12) Can be mounted behind blanking plates, as widely used in residential wiring systems such as; BTicino: Axolute, Matix, Living e Magic, Gewiss: GW24, Vimar: Plana e Idea (13.31) 35 mm rail (EN 60715) or flange mount (13.11 and 13.12) Cadmium free contact material (13.31) 13.11/12/31 Screw terminals CO (SPDT) Call relay with reset command 17.5 mm wide 1 CO (SPDT) + 1 NO (SPST-NO) Call relay with reset command 17.5 mm wide 1 NO (SPST-NO) Interposing monostable relay For mounting within residential switch boxes * During impulse only. For outline drawing see page 10 Contact specification Contact configuration 1 CO (SPDT) 1 CO (SPDT) + 1 NO (SPST-NO) 1 NO (SPST-NO) Rated current/maximum peak current A 12/30 8/15 12/20 (80 A - 5 ms) Rated voltage/ Maximum switching voltage V AC 250/ / /400 Rated load AC1 VA Rated load AC15 (230 V AC) VA Nominal lamp rating: 230 V incandescent/halogen W fluorescent tubes with electronic ballast W fluorescent tubes with electromechanical ballast W CFL W V LED W LV halogen or LED with electronic ballast W LV halogen or LED with electromechanical ballast W Minimum switching load mw (V/mA) 500 (5/5) 300 (5/5) 1000 (10/10) Standard contact material AgCdO AgCdO AgSnO 2 Supply specification Nominal voltage (U N ) V AC (50/60 Hz) V DC Rated power AC/DC V A (50 Hz)/W 1.7/0.7* 3/2.5* 1/0.4 Operating range AC (50 Hz) ( )U N ( )U N ( )U N DC ( )U N ( )U N Technical data Electrical life at rated load in AC1 cycles Maximum impulse duration 10 s (100 ms minimum) 10 s (100 ms minimum) continuous Dielectric strength between: open contacts V AC supply - contacts V AC Ambient temperature range C Protection category IP 20 IP 20 IP 20 Approvals (according to type) 3
4 13 13 Electronic step/monostable and call/reset Ordering information Example: 13 series, electronic step/monostable relay, 35 mm rail (EN 60715) mount, 1 CO (SPDT) 16 A contact, 230 V AC supply. A B C D Series Type 0 = Step/Monostable, 35 mm rail (EN 60715) mount, 35 mm wide 1 = Call & Reset relay, 35 mm rail (EN 60715) mount, 17.5 mm wide 3 = Monostable relay, switch box mounting 6 = Multifunction relay, 35 mm rail (EN 60715) mount, 17.5 mm wide 8 = Modular step relay, 35 mm rail (EN 60715) mount, 17.5 mm wide 9 = Step relay and timing step relay, switch box mounting No. of poles 1 = 1 pole 2 = 1 pole CO (SPDT) + 1 NO (SPST-NO) Supply version 0 = AC (50/60 Hz)/DC 8 = AC (50/60 Hz) 9 = DC Supply voltage 012 = 12 V AC/DC (13.01 and only) 012 = 12 V AC (13.31 only) 024 = 24 V AC/DC (13.01 and only) 024 = 24 V DC (13.31 only) 024 = V AC/DC (13.61 only) 125 = ( )V AC (13.01 only) 230 = ( )V AC (13.01 and 13.11) 230 = V AC (13.61 only) 230 = 230 V AC (13.31, and 13.91) A: Contact material 0 = Standard 4 = Standard AgSnO 2 (only for 13.31) B: Contact circuit 0 = Standard 3 = Standard NO (only for 13.31) Codes / Supply voltage V AC/DC V AC/DC V AC V AC V AC V AC/DC V AC/DC V AC V DC V AC V AC V AC/DC V AC V AC Technical data Insulation Dielectric strength between control circuit and supply V AC 4000 between control circuit and contacts V AC between R-S-A2 and contacts V AC 2000 between supply and contacts V AC between open contacts V AC Other data Power lost to the environment without contact current W with rated current W 3.5 1, Max cable lenght for push-button connection m Max. no. of illuminated push-button ( 1mA) 10* Terminals Max. wire size solid cable stranded cable solid cable stranded cable mm 2 1 x 6 / 2 x 4 1 x 6 / 2 x x 6 / 2 x 4 1 x 4 / 2 x 2.5 AWG 1 x 10 / 2 x 12 1 x 10 / 2 x 14 1 x 10 / 2 x 12 1 x 12 / 2 x 14 Screw torque Nm * For version. 4
5 13 Electronic step/monostable and call/reset 13 Functions Type Monostable On closure of a switch between terminals (B2-B3) the output contact will close, and remain so, until the switch opens. Step relay (bistable) After every impulse (B1-B2), the output contact changes state - alternately switching from open to closed and vice versa (13.12 only) Call and Reset relay On momentary closure of the Set switch (S), the output contact closes. Only a momentary closure of the Reset switch (R) will open the output contact. (RI) Step relay After every impulse, the output contact changes state - alternately switching from open to closed and vice versa (RI) Step relay After every impulse, the output contact changes state - alternately switching from open to closed and vice versa. (IT) Timing step relay On initial impulse the output contact closes and timing starts for the pre-set duration (fixed 10 min); On expiry of the time delay, the output contact opens. During the timing period it is possible to immediately open the contact with a further impulse. Operating mode setup for type RI IT a) Remove the supply voltage b) Press the control button c) Apply the supply to the relay, keeping the button closed. After 3 second, the light will flash twice to indicate the selection of the IT function, or flash once for RI function. IT RI 5
6 13 13 Electronic step/monostable and call/reset Functions Type Functions (RM) Monostable On closure of a switch between terminal 3 and Line (or Neutral, in case of 3-wire connection) the output contact will close, and remain so, until the switch opens. (IT) Timing step relay On initial impulse the output contact closes and timing starts for the pre-set duration T; On expiry of the time delay, the output contact opens. During the timing period it is possible to immediately open the contact with a further impulse. (RI) Step relay After every impulse, the output contact changes state - alternately switching from open to closed and vice versa. Light ON With this function set - the output contact stays permanently closed (RM) Monostable On closure of a switch between terminal 3 and Line (or Neutral, in case of 3-wire connection) the output contact will close, and remain so, until the switch opens. (IT) Timing step relay On initial impulse the output contact closes and timing starts for the pre-set duration T; On expiry of the time delay, the output contact opens. During the timing period it is possible to immediately open the contact with a further impulse. (RI) Step relay After every impulse, the output contact changes state - alternately switching from open to closed and vice versa. Light ON With this function set - the output contact stays permanently closed. 6
7 13 Electronic step/monostable and call/reset 13 Wiring diagrams (13.01, 13.11, and 13.31) Type Step wiring diagram Type Monostable wiring diagram Type Call & reset relay Type Call & reset relay Reset Reset Set Set Type Connection 7
8 13 13 Electronic step/monostable and call/reset Wiring diagrams (13.61) Type wire connection Blinking = relay OFF Type wire connection Blinking = relay OFF Reset Reset Max 10 ( 1 ma) illuminated push buttons Max 10 ( 1 ma) illuminated push buttons Type wire connection Blinking = relay OFF L (+) V AC/DC N (-) Reset Set Type Examples of multiple 4 wire connection with centralized reset pushbutton 8
9 13 Electronic step relays 13 Wiring diagrams (13.81 and 13.91) Type wire connection Blinking = relay OFF Type wire connection Blinking = relay OFF L N Max 15 ( 1 ma) illuminated push buttons Max 15 ( 1 ma) illuminated push buttons Type wire connection Type wire connection Max 12 ( 1 ma) illuminated push buttons Max 12 ( 1 ma) illuminated push buttons 9
10 13 13 Electronic step relays Outline drawings Screw terminal Screw terminal Screw terminal 13.31/13.91 Screw terminal Screw terminal Screw terminal 10
11 13 Electronic step relays 13 Accessories Adaptor for panel mounting, for type 13.01, 35 mm wide Adaptor for panel mounting, for type 13.11, 13.12, and 13.81, 17.5 mm wide Sheet of marker tags for type, 13.11, 13.12, and 13.81, plastic, 72 tags, 6 x 12 mm Sheet of marker tags (CEMBRE'S Thermal transfer printers) for relays types 13.11, 13.12, and (48 tags), 6 x 12 mm
12
80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 6 A 80. Multi-function and mono-function timer range - Multi-function & multi-voltage 80. - ON delay, multi-voltage 7.5 mm wide Six time scales from 0.s to 24h 35 mm rail (EN
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
12 Series - Time switches 16 A. Features 12.01 12.11 12.31
Mechanical time switches - daily time setting Type 12.01-1 Pole 16 A CO (SPDT) Type 12.11-1 Pole 16 A O (SPST-O) 17.6 mm width Type 12.31-0000 - 1 Pole 16 A CO (SPDT) Type 12.31-0007 - 1 Pole 16 A CO (SPDT)
15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
60 Series - General purpose relays 6-10 A. Features 60.12 60.13
Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)
40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52
Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail
Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51
34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in
93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal
Series - Timed socket for 34 series Features.68/.69 Slim timed sockets for 34 series, 6.2 mm wide Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch
1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting
Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
70 Serie - Line monitoring relay 70 SRIS Feature 70.11 70.31 lectronic voltage monitoring relay for ingle and three-phae application Multifunctional type, providing the flexibility of monitoring Undervoltage,
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
RY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC
April 00 D Series Standard and Full Featured - Catalogue Number Structure Table -. D Series Catalogue Numbering System Family Type DPR = Standard Relay DPF = Full Featured Relay Contact Configuration =
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011
Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are
Control Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
ABB i-bus KNX SA/S Switch Actuators Product Manual
ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Relays, Timers, Interface Modules, Sockets and Accessories. 2002-2003 Catalogue. S.p.A. ISO 9001 ISO 14001. The power in relays and timers since 1954
Relays, imers, Interface Modules, Sockets and Accessories. 00-003 atalogue he power in relays and timers since 95 S.p.A. ISO 900 ISO 00 he power in relays ISO 900 ISO 00 Finder s 0,000 different products
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011
, 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially
basicdim DGC Compact control module
luxctrol lighting control sstem DGC Compact control module Product description Compact dimensions for luminaire installation For up to 0 DSI or LI ballasts ( per output channel) LI IN input LI/DSI output
1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) HIGH INSULATION Insulation distance (between coil and
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
3-phase, bidirectional energy meter
Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured
Reference. 910 402 230 V, 50 Hz A10 415 120 V,60 Hz. 916 402 230 V, 50/60 Hz A16 418 120 V, 50/60 Hz. 910 103 230 V, 50 Hz A10 104 120 V, 60 Hz
Rex - analog time switches MicroRex - 3 modules for DIN rail mounting Rex - analog time switches MicroRex - module for DIN rail mounting 926 428 A0 4 MicroRex T3 24 hour program, synchronous motor 92 429
E-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Pluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
J TB/TW Temperature limiter, temperature monitor
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
Electro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
Solid-State Timer H3G
ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In
LAUBE TECHNOLOGY DRY REED RELAYS
LAUBE TECHNOLOGY DRY REED RELAYS CONTACT FORM CURRENT PART SERIES PAGE #'S (1A) SPST-NO 1 AMP D41A...0L 147~148 (Link) (1A) SPST-NO 1 AMP D71A.1.0 149~150 (Link) (1A) SPST-NO 1 AMP F51A.100 151~152 (Link)
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Catalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series
Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series Product description Independent dimmable LED control gear Constant current LED control gear Output current adjustable between 900 1,750 ma Max. output
mecotron Safety relay ESTOP-2 For emergency stop monitoring
E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated
PNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8
System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures
SKR - industry relay
SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt TDB106015en/05.2013 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
PHOENIX CONTACT - 2012-12-14. Features
Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) High insulation Insulation distance (between coil and
225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators
Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5
HCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
Technical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch
2 Wire Electronic Time Delay Switch Cat No. DS1 2 Wire Slave Switch Cat No. DSS 3 Wire Electronic Time Delay Switch Cat No. DS2 Installation & Operating Instructions DS1/DSS Instructions for Installation
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
Solid State Timers Type F
Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
instabus KNX / EIB System System E F G H
Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA
Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48
Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 0, RS 8 Zero switching AC Solid State Relay Direct copper bonding (DCB) technology in 25A and 0A types LED indication Clip-on IP 20 protection
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
E-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous
ABB i-bus KNX Switch Actuators SA/S Product Information
ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,
EBDSPIR-DD, EBDSPIR-DD-IP
Product Guide EBDSPIR-DD, EBDSPIR-DD-IP Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSPIR-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with
1 POLE - 8A Medium Load Control
POWER RELAY 1 POLE - 8A Medium Load Control JS Series FEATURES UL class B (130 C) coil wire insulation 1 form A (SPST-NO) or 1 form C (SPDT) contact Low profile and space saving - Height: 12.5 mm - Mounting
Switches & Pilot Devices
Key features: 21/4 (8mm) round mounting hole Compact Design Saves Space Bright and Vivid Illumination Choice of Shapes and Functions old Clad Silver Contacts for reliable low level switching Snap action
LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series
Udriver LCAI 100W 900mA 1750mA ECO SR ECO series Product description Independent dimmable LED Driver Constant current LED Driver Output current adjustable between 900 1,750 ma Max. output power 100 W Suitable
DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions
DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable