1 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009
2 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal Enclosures? > Schneider Electric Universal Enclosures has the mission to develop and be in charge of the Universal Enclosure Business for the Schneider Electric Group. > Schneider Electric Universal Enclosures is based on two historical companies created in 1958, Himel with origin in Spain and Sarel with origin in France. Both companies have developed more than 50 years of experience in the design, manufacturing and marketing of universal enclosures systems. > Himel and Sarel brands are going to migrate within Schneider Electric which is an ambitious corporate project that will make everyone s day-to-day work easier, both clients and collaborators. Why do we migrate our brands? Here are some of the benefits of working with a single brand: > Our daily work will be simpler, it is easier to deal with a single brand and with common documentation and resources. > Your clients will recognize our product offer and ranges better thanks to a single packing and communication focused on Schneider Electric. > It will be much easier to create solutions based on the products of a single brand. What is good for Schneider Electric is also good for our clients and collaborators! > The scope of this guide is limited to the ranges migrating last quarter of These ranges are Floor Standing, Control Desks, Thermal offer, Stainless Steel and Plastic Industrial Boxes. Customer needs Brand migration How will be the migration process? The migration process of the ranges in the scope of this guide will be conducted in a range-by-range basis during the last quarter of 2009, and each one of the range migrations will be performed in two phases: Phase 1: new packing This phase began in the second half of 2009, and will focus on harmonizing the packing with Schneider Electric. Schneider Electric Solutions Phase 2: new product marking As of the fourth quarter of 2009, some product families will start to carry the Schneider Electric logo. This process will be performed progressively range by range. > To guarantee a global offer and a harmonized coding and marking system, we are also going to change our references for all our ranges.
3 ClimaSys Thermal management system Thermal conditioning of electric and electronic switchboards: a need What is thermal control? Technological evolution The miniaturisation of components, the generalisation of electronics and the appearance of new electronically powered products have made temperature management into a growing need which must necessarily be considered when designing electrical and/or electronic switchboards. What are the advantages of efficient thermal management? Thermal management of electrical switchboards is a major factor for industrial maintenance. Many risks are incurred by not having a suitable thermal solution, which can affect the service life of the components and the performance of the facilities to the extent of causing a halt in production. The service life of the components also depends on the temperature and humidity conditions inside the enclosure. The ideal values range from +25 to +35 ºC for the temperature and 40 to 60 % for the relative humidity (RH). Cooling, heating, controlling For the same reasons as the IP/IK protection ratings, equipment installed in enclosures requires suitable thermal protection. Various solutions to these problems have been put forward. They will be chosen according to environmental conditions, the type of components in the electrical switchboard, etc. In certain cases, it is sufficient to oversize the enclosure, use fans or air-air exchangers, etc. In other cases, where the ambient temperature is higher, it becomes necessary to install air-water exchangers or cooling units. A solution for each need We provide a complete Thermal offer to secure your installations. Cooling 1. Forced ventilation systems 2. Air-air exchangers 3. Air-water exchangers 4. Cooling units Heating Controlling Calculating 5. Resistance heaters 6. Thermal control accessories 7. New Spacial.clim software 3
4 ClimaSys Choose the solution A thermal solution for every environment Ventilation systems with filters Specially recommended for installations in which: The ambient temperature is lower than the desired temperature inside the enclosure. A high protection rating is required: IP 54 or IP 55. The surrounding environment is relatively clean, allowing air to enter the enclosure. Large range of solutions 42 possible combinations. Colours: RAL 7035 as standard, with the option of changing to RAL 7032 (with replacement grille NSYCAGpppLPC). 38 to 850 m 3 /h. According to 5 input voltages: AC: 400/440 V, 230 V, 115 V (50/60 Hz), DC: 48 V and 24 V. Broad range of accessories (filters, IP 55 & EMC covers, anti-vandalism kit). Air-air exchangers Specially recommended for installations in which: The ambient temperature is lower than the desired temperature inside the enclosure. A high protection rating is required: IP 54 or IP 55. The outside environment is highly polluted. Large range of solutions 4 models. Two installation versions: top-mounting model and side-mounting model. Cooling power from 15 to 70 W/ºK. According to the input voltage: 230 V (50/60 Hz). Air-water exchangers Specially recommended for installations in which: The ambient temperature is higher than the desired temperature inside the enclosure. The outside environment is corrosive, the internal and external air circuits are independent. The outside environment is highly polluted, the temperature is controlled by cold water without requiring the use of an external air circuit. It is necessary to extract the heat produced by the industrial site. Large range of solutions 3 models. Two installation versions: top-mounting model and side-mounting model. Cooling power of 2,100 W and 3,150 W. According to the input voltage: 230 V (50/60 Hz). 4
5 ClimaSys Choose the solution A thermal solution for every environment Cooling units They control the temperature inside the enclosure in order to guarantee the correct operation of the components, regardless of the outside temperature, by separating the internal and external air circuits and reducing the humidity of the enclosure. A very broad range of solutions 32 models. Two versions: top-mounting model and side-mounting model. Cooling power from 240 to 4,000 W. Two control versions: electronic and mechanical. According to the input voltage: 230 V (50/60 Hz); 3 400/440 V (50/60 Hz); 115 V (50/60 Hz). Three installation types: surface, flush and partial flush (SLIM version). RAL 7035 and stainless steel. Resistance heaters With a double objective: To prevent the formation of condensation inside the enclosure. To reheat the electrical switchboard when the temperature is too low for the components to operate correctly. Large range of solutions 30 models. Insulated or aluminium versions. Versions with natural convection or fan. Cooling power from 10 to 1,200 W. According to the input voltage: 12 V to 450 V AC/DC. Thermal control Thermostats maintain the temperature inside the enclosure and send a signal when certain defined values are exceeded: Maximum value (cooling action). Minimum value (reheating action). Range of solutions 11 models. Temperature control: adjustable thermostats; single or double. Relative humidity control: adjustable or fixed hygrostat. Temperature and relative humidity control: adjustable hygrotherm. Calculation assistance: Spacial.clim We offer our customers and users a software application to help them select thermal accessories. The programme draws up a heat balance and defines the best ventilation or cooling solution for the inside of the enclosure. 5
6 ClimaSys CV Ventilation system Selection guide Ventilation systems with filters Fan flow rate (m 3 /h) Free with filter With 1 outlet grille With 2 outlet grilles Voltage Dimensions (mm) IP 54 IP 54 IP 54 IP 54 IP 20 IP Hz 50 Hz 50 Hz Total Fan with filter Outlet grille Colour kit Cut-out (external) RAL 7035 RAL V NSYCVF38M230PF V NSYCVF38M115PF V CC NSYCVF38M24DPF NSYCAG92LPF NSYCAG92LPC V CC NSYCVF38M48DPF V NSYCVF85M230PF V NSYCVF85M115PF V CC NSYCVF85M24DPF NSYCAG125LPF NSYCAG125LPC V CC NSYCVF85M48DPF V NSYCVF165M230PF V NSYCVF165M115PF V CC NSYCVF165M24DPF V CC NSYCVF165M48DPF V NSYCVF300M230PF V NSYCVF300M115PF V CC NSYCVF300M24DPF V CC NSYCVF300M48DPF V 115 V NSYCVF560M230PF NSYCVF560M115PF V NSYCVF850M230PF V NSYCVF850M115PF /440 V NSYCVF850M400PF V NSYCVF65M115PF (1) Ø V NSYCVF65M230PF (1) NSYCAG223LPF NSYCAG291LPF NSYCAG108LP (1) V NSYCVF54M230MM2 (2) NSYCAG223LPC NSYCAG291LPC (1) Black colour. (2) Integrated in the kit. Sealing cover IP 55 and EMC External Dimensions (mm) Cut-out Aluzinc RAL 7035 Cover reference Stainless steel 304 EMC Cover reference Aluzinc RAL NSYCAP125LZF NSYCAP125LXF NSYCAP125LE NSYCAP223LZF NSYCAP223LXF NSYCAP223LE NSYCAP223LZF NSYCAP223LXF NSYCAP223LE NSYCAP291LZF NSYCAP291LXF NSYCAP291LE NSYCAP291LZF NSYCAP291LXF NSYCAP291LE Anti-vandalism kit Prevents the grille from being opened from the outside. The unlocking thumbwheel is accessed from the inside of the wall-mounting enclosure. RAL 7011 colour (same material as the grille: ASA PC). Minor packaging 2 NSYCAAPV 6
7 ClimaSys CV Ventilation systems Natural airing Anti-insect filters for metal louvre plate, square Installation is made between the enclosure and the metal louvre. Material: Stainless steel 304L 0.32 mm wire mesh, of 1.07 mm, thickness 0.6 mm. Increases protection rating to IP 33. Weight: 0.8 kg/m 2. Supply: one anti-insect filter. Louvre plate reference External dimensions (mm) Filter reference NSYCAG104X95LM NSYCAF104X95X NSYCAG130X110LM NSYCAF130X110X NSYCAG170X190LM NSYCAF170X190X Plastic ventilation louvres Four models available according to IP rating, in vertical position. Supply: 2 plastic ventilation louvres. NSYCAG45LP NSYCAG33LP cut-out IP 45.5 mm 22 NSYCAG45LP 35 mm 30/44 (1) NSYCAG35LP 38 mm 45 NSYCAG38LP 33 mm 44 NSYCAG33LP 19 mm 45 NSYCAG19LP (1) According to installation in the Thalassa enclosure. Hood for natural airing, IP 54 Natural airing device for coupling to the top of metal floor-standing enclosures. Solution for combining with the ventilation slots. Fixing to the top by means of caged nuts and special screws. Material: steel. Finish: painted with epoxy-polyester resin, textured RAL 7035 grey. Protection rating: IP 54. Weight: 4.6 kg. Supply: one hood for natural airing and fixing elements. NSYCAC228RMF Top hood with top fan IP 54 Fan with hood, for floor-standing enclosures. Device delivered with fixings and connection terminal block. Electric power: 85 W. A flow rate of 350 m 3 /h is obtained with an outlet grille ref. NSYCAG291LPF, (cut-out mm). Noise level: 64 db (A). Installation and removal from the outside. Flow rate* (m 3 /h) Voltage (V) Weight (kg) NSYCVF570M115MF NSYCVF575M230MF * Flow rate measured without counter-pressure. 7
8 ClimaSys CU Cooling unit SLIM electronic control SLIM for perfect integration + = 1 bloc: 4 power levels 3 voltage levels 1 cover: Flush Partial-flush Surface 66 models, from 1,100 to 2,700 W, 115 to 460 V, flush mounting, partial-flush mounting or surface mounting, with or without electronic display, IP 55, UL compliant. 162 mm Depth Minimum depth All the models of the SLIM range have a depth of 162 mm to maximise the volume inside the enclosure. Modular system There are 66 possible combinations with only 17 catalogue references. Three different installation types are possible with the same air-conditioning unit (surface, partial flush and flush). Power ranges 1,100 W, 1,500 W, 2,200 W and 2,700 W. Versions RAL 7035 and stainless steel. Option to provide other colours on demand. Internal IP 55 The SLIM range is supplied as standard with an expanded polyurethane gasket, ensuring optimum sealing with IP 55 throughout the enclosure. 8
9 ClimaSys CU Cooling unit Selection guide SLIM electronic control models (modular) Flush mounting. Partial-flush mounting. Surface mounting. Power 1,100 W 1,500 W 2,200 W 2,700 W Cooling unit block 230 V NSYCUB1100W230S NSYCUB1500W230S NSYCUB2200W230S NSYCUB2700W230S V (50-60 Hz) NSYCUB1100W400S NSYCUB1500W400S NSYCUB2200W400S NSYCUB2700W400S 115 V NSYCUB1100W115S NSYCUB1500W115S NSYCUB2200W115S Covers Side-mounting type Surface-mounting NSYCUCL RAL 7035 Partial flush-mounting NSYCUCH Flush-mounting NSYCUCF Surface-mounting NSYCUCLX Stainless-steel Partial flush-mounting NSYCUCHX Flush-mounting NSYCUCFX! Modular version: Always order one SLIM cooling unit reference plus one cover reference. Side-mounting models External dimensions (mm) Cooling power EN L35 - L35 (50 Hz) Input voltage Vol-Hz Control W (819 Btu/h) 230 V - 50/60 Hz Thermostat NSYCU240W230VL W (1263 Btu/h) 230 V - 50/60 Hz Thermostat NSYCU370W230VL W (2594 Btu/h) 230 V - 50/60 Hz Thermostat NSYCU760W230VL ,050 W (3584 Btu/h) 230 V - 50/60 Hz Thermostat NSYCU1050W230VL 1, ,100 W (3755 Btu/h) 230 V - 50/60 Hz Electronic controller NSYCUE1100W230L 1, ,400 W (4780 Btu/h) 230 V - 50/60 Hz Electronic controller NSYCUE1400W230L 1, ,400 W (4780 Btu/h) V 50 Hz / 440 V 60 Hz Electronic controller NSYCUE1400W400L 1, ,650 W (5631 Btu/h) 230 V - 50/60 Hz Thermostat NSYCU1650W230VL 1, ,800 W (6143 Btu/h) V 50 Hz / 440 V 60 Hz Thermostat NSYCU1800W400VL 1, ,800 W (6145 Btu/h) V 50 Hz / 440 V 60 Hz Electronic controller NSYCUE1800W400L 1, ,500 W (8533 Btu/h) V 50 Hz / 440 V 60 Hz Thermostat NSYCU2500W400VL 1, ,000 W (13652 Btu/h) V 50 Hz / 440 V 60 Hz Thermostat NSYCU4000W400VL Top-mounting models External dimensions (mm) Cooling power EN L35 - L35 (50 Hz) Input voltage Vol-Hz Control W (2594 Btu/h) 230 V - 50/60 Hz Thermostat NSYCU760W230VR ,050 W (3584 Btu/h) 230 V - 50/60 Hz Thermostat NSYCU1050W230VR ,400 W (4780 Btu/h) 230 V - 50/60 Hz Electronic controller NSYCUE1400W230R ,460 W (4983 Btu/h) 230 V - 50/60 Hz Thermostat NSYCU1460W230VR ,650 W (5631 Btu/h) 230 V - 50/60 Hz Thermostat NSYCU1650W230VR ,800 W (6145 Btu/h) V 50 Hz / 440 V 60 Hz Electronic controller NSYCUE1800W400R ,000 W (6826 Btu/h) V 50 Hz / 440 V 60 Hz Thermostat NSYCU2000W400VR ,450 W (8362 Btu/h) V 50 Hz / 440 V 60 Hz Thermostat NSYCU2450W400VR ,100 W (10580 Btu/h) V 50 Hz / 440 V 60 Hz Thermostat NSYCU3100W400VR 9
10 ClimaSys CE Air-water exchanger Side and top-mounting models General characteristics Main components: thermostatic adjustment system, exchange cassette, fans for the internal circuit of the enclosure, safety device against possible leaks. The desired temperature inside the enclosure can be adjusted over a range of ºC. The alarm which detects an interruption in the water circuit is activated by closing a switch. This can be used to activate a light or a siren, connected to the input of an automation device. The water supply is automatically cut. System for evacuating condensation water to the outside. RAL 7035 grey. Conditions of use Air-water exchangers can be used even when the outside temperature is higher than the desired temperature inside the enclosure. The enclosure must be sealed to prevent the entry of external air: at least IP 54. NSYCEW2100W230VR (top) NSYCEW2100W230VL (side) NSYCEW3150W230VL (side) Cooling characteristics Specific power A 35 W l/h 2,100 W 2,100 W 3,150 W Maximum water pressure 1 MPa 1 MPa 1 MPa Air flow of the external circuit 250 m 3 /h 350 m 3 /h 820 m 3 /h Adjustment Yes Yes Yes Type Thermostatic Thermostatic Thermostatic Temperature setting range C C C Nature of the fluid Water Water Water Electric characteristics Input voltage 230 V - 50/60 Hz 230 V - 50/60 Hz 230 V - 50/60 Hz Starting/rated current 1/0.5 A 1/0.5 A 1.3/1.7 A Electrical energy absorbed 90 W 90 W 295 W/385 W Type of switching alarm Inverter contact Inverter contact Inverter contact Physical characteristics External dimensions A x B x C (mm) IP-DIN IP 54 IP 54 IP 55 Weight of unit 26 kg 19 kg 21 kg Noise level 64 db (A) 62 db (A) 54 db (A) 10
11 ClimaSys CE Air-air exchanger Side and Top-mounting models General characteristics Main components: thermostatic adjustment system, exchange cassette, circulation fans for internal and external circuits. The desired temperature inside the enclosure can be adjusted over a range of C. The internal and external air circuits are completely separated (IP 54). Two fans guarantee air circulation in each of these circuits. The one on the internal circuit (which circulates the air inside the enclosure) is permanently on to avoid the appearance of hot spots in the electric circuits or components. The devices are delivered with a cut-out template, an instruction sheet and a sealing gasket to be placed between the exchanger and the enclosure. RAL 7035 grey. Voltages on demand with 400 V AC, three phase or single phase. Conditions of use The exchangers can only be used if the outside temperature is at least 5 ºC lower than the desired temperature inside the enclosure. The enclosure must be sealed to prevent the entry of external air: at least IP 54. NSYCEA15W230VL NSYCEA35W230VL NSYCEA35W230VLE NSYCEA70W230VL Cooling characteristics Specific power (1) 15 W/ K 35 W/ K 35 W/ K 70 W/ K Air flow of the external circuit 200 m 3 /h 450 m 3 /h 450 m 3 /h 450 m 3 /h Air flow of the internal circuit 200 m 3 /h 450 m 3 /h 450 m 3 /h 450 m 3 /h Exchange surface 1.23 m m m m 2 Adjustment Yes Yes No Yes Type Thermostatic Thermostatic Thermostatic Thermostatic Temperature setting range C C C Nature of the fluid Air Air Air Air Electric characteristics Input voltage 230 V - 50/60 Hz 230 V - 50/60 Hz 230 V - 50/60 Hz 230 V - 50/60 Hz Starting/rated current 2.1/0.7 A 2.1/0.7 A 2.1/0.7 A 2.1/0.7 A Electrical energy absorbed 150 W 150 W 150 W 150 W Physical characteristics External dimensions A B C (mm) , Internal IP / external IP IP 54/IP 22 IP 54/IP 22 IP 54/IP 22 IP 54/IP 22 Weight of unit 12 kg 15 kg 15 kg 35 kg Noise level 64 db 64 db 64 db 64 db (1) The power in watts is obtained by multiplying the specific power by the difference between inside temperature and outside temperature. Example: for exchanger ref. NSYCEA35W230VL with ºC = 10º, the system power is = 350 W. 11
12 ClimaSys CR Resistance heaters Selection guide Insulated resistance heater with fan Power (W) Voltage (V) Connection type Terminal block AC NSYCR170W230VVC Thermofans Power (W) Voltage (V) Connection type Terminal block AC NSYCR350W230VTVC 400/ AC NSYCRP1W120VTVC 400/ AC NSYCRP1W230VTVC NSYCR350W230VTVC Resistance heaters Connection type Power (W) Voltage (V) Terminal block Cable DC NSYCR10WU AC NSYCR10WU DC NSYCR20WU AC NSYCR20WU AC NSYCR20WU DC NSYCR55WU AC NSYCR55WU AC NSYCR55WU DC NSYCR100WU AC NSYCR100WU AC NSYCR100WU DC NSYCR150WU AC NSYCR150WU AC NSYCR150WU3 Resistance heaters with fan NSYCRS200W230V Power (W) Voltage (V) Connection type Terminal block AC NSYCR250W115VV AC NSYCR250W230VV AC NSYCR400W115VV AC NSYCR400W230VV AC NSYCRS200W115V AC NSYCRS200W230V Insulated resistance heaters Power (W) Voltage (V) Connection type Terminal block DC NSYCR10WU1C AC NSYCR10WU2C DC NSYCR20WU1C AC NSYCR20WU2C DC NSYCR55WU1C AC NSYCR55WU2C AC NSYCR55WU3C DC NSYCR100WU1C AC NSYCR100WU2C AC NSYCR100WU3C DC NSYCR150WU1C AC NSYCR150WU2C 12
13 ClimaSys CC Thermal control Selection guide mechanical version Control temperature Control a resistance heater or an alarm Setting range Display Contact Application Control element Interrupting capacity (resistive load) C C 30 W DC NSYCCOTHC O Heat Bimetal 120 V AC; 15 A F F 250 V AC; 10 A NSYCCOTHCF NC thermostat Control a fan or an alarm Setting range Display Contact Application Control element Interrupting capacity (resistive load) C C 30 W DC NSYCCOTHO NO Ventilate Bimetal 120 V AC; 15 A F F 250 V AC; 10 A NSYCCOTHOF NO thermostat Control a resistance heater and a fan Setting range Display Contact Application Control element Interrupting capacity (resistive load) C C NC 30 W DC Heat / NSYCCOTHD + Bimetal 120 V AC; 15 A F F Ventilate NO 250 V AC; 10 A NSYCCOTHDF Double thermostat Control a resistance heater or a fan Setting range Display Contact Application Control element Interrupting capacity (resistive load) Closing: 30 W DC C C NSYCCOTHI Heat or 250 V AC; 5 A Inverse Bimetal ventilate Opening: 30 W DC F F NSYCCOTHIF 250 V AC; 10 A Thermostat with inverse contact 13
14 ClimaSys CC Thermal control Selection guide electronic version Control temperature Control a resistance heater or a fan Setting range Display Power input Application Control element No. of Interrupting capacity relays (resistive load) Electronic thermostat 9-30 V AC/DC NSYCCOTH30VID +5 C +50 C C or F V AC Heat or 8 (5) A 230 V AC Electronic 2 ventilate 5 A 30 V DC NSYCCOTH120VID 230 V AC NSYCCOTH230VID 7 different operating modes. Option of installing an external sensor. Control temperature and relative humidity Setting range Display Power input Application Control element No. of Interrupting capacity relays (resistive load) Electronic hygrotherm 9-30 V AC/DC NSYCCOHYT30VID +5 C +50 C C or F V AC Heat or 8 (5) A 230 V AC Electronic 2 ventilate 5 A 30 V DC NSYCCOHYT120VID 230 V AC NSYCCOHYT230VID 3 different operating modes. Option of installing one or two external sensors. Control relative humidity Setting range Display Power input Application Control element No. of Interrupting capacity relays (resistive load) 20% 80% % RH 230 V AC Heat or ventilate Electronic 2 8 (5) A 230 V AC 5 A 30 V DC NSYCCOHY230VID Electronic hygrostat 2 different operating modes. PTC external temperature sensor (double insulation) Length: 3 metres. Several types of fixings (on DIN rail, on Spacial SF profile, on VDI cross-rail, on mounting plate). Sensor operation or reading range: -30 C +80 C. Protection rating: IP 67. NSYCCAST Temperature sensor Thermostat installation tips: The thermostat should be installed at the top of the enclosure (the hottest place). See the various operating modes of each thermostat to choose the one that best meets your needs. Hygrostat installation tips: The hygrostat should be installed at the bottom of the enclosure. 60% RH is the optimum value in the enclosure. 14
15 Make the most of your energy Contact: Schneider Electric Romania Due to the evolution of standards and materials, the characteristics indicated by the text and images of this document are not binding for us until our services have confirmed them.
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Rittal TopTherm fan-and-filter unit
Rittal TopTherm fan-and-filter unit System Climate Control More pressure. Higher air flow rates. 2 Assembly without tools Straightforward assembly, exchange and maintenance with no need for tools of any
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?
Data Bulletin April 2001 Raleigh, NC, USA Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW Variable frequency drives are available from manufacturers as enclosed engineered
Brochure 2012-2013.EX
CLIMA CANAL Brochure 2012-2013.EX CLIMA CANAL Complete climate control and high power Heating, cooling, ventilation. Despite it s modest size, clima canal is a powerful heating, cooling and ventilation
The space saving solution.
10 KICKSPACE KICKSPACE. Over 70% of people think that they would benefit from additional kitchen space (ICM Research 2012) Kitchen kindly supplied by Second Nature kitchens - www.sncollection.co.uk The
1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
Under sill units. Type FSL-B-ZAS
.1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Guide to enclosures for potentially explosive atmospheres
Guide to enclosures for potentially explosive atmospheres Guide to enclosures for potentially explosive atmospheres The safety of every application, in every environment, thanks to ATEX-certified steel,
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:
PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV
Linkeo 19" freestanding cabinets
87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000
Filterfans Patented Click & Fit design provides a hardware free installation! Poured-in foam gasket allows for quick NEMA 12 sealing against the enclosure (except PF 1000) Plastic made from strong (ABS-FR),
IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner
Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design
.8 Ex-Recess-mounted, ceiling emergency light fittings in compact metal design RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX 50... N 18-36 W (Zone 1,, 1, ) The explosion-protected lighting concept for clean rooms
Morgue refrigeration unit
Morgue refrigeration unit The Morgue refrigeration units are made of sturdy, self-supporting walls, floor and ceiling elements. They are delivered in separate components and are to be assembled on site
IntesisBox KNX LG Air Conditioning
IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
IntesisBox KNX Modbus RTU master
IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control
Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems
Knürr CoolAdd The universal retrofit solution against overheating in server racks Rack & Enclosure Systems Knürr CoolAdd When cold air is no longer enough! Data centers are subject to constant changes:
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
KONRAD. Hybrid Fancoil Series
KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks
Electric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
J TB/TW Temperature limiter, temperature monitor
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: [email protected] Internet: www.jumo.net
SERVER ROOM CABINET INSTALLATION CONCEPTS
SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Conlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
Cold Room & Refrigeration System (Casserole Assembly) No of units: 1
Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency
Transformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
Mitel DECT Base Stations
Mitel DECT Base Stations On-site Mobility for Professionals The Mitel BS300 range of base stations offers a variety of coverage patterns to suit different situations. By choosing the right mix of base
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
RRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.
IntesisBox KNX SAMSUNG Air Conditioning Gateway for integration of Samsung air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX EIB Bus IntesisBox RS485 MIM-B13x/B04A
Weiss Mobile Air Conditioning Systems
Weiss Mobile Air Conditioning Systems SHELTER AIR CONDITIONING System Weiss Umwelttechnik GmbH Simulationsanlagen Messtechnik Worldwide... Weiss Umwelttechnik GmbH is one of the world s most important
ABLOY DOOR AUTOMATICS Easy access for all types of swing doors
ABLOY DOOR AUTOMATICS Easy access for all types of swing doors Automatic door operators bring additional convenience in situations where the doors opening manually would be inconvenient or laborious. Recommended
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.
19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile
Visions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
IntesisBox KNX - LON
IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,
Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.
Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally
Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)
NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications 686 - XX - XX - XXX - XX
Ordering specifications MTraB -Series Maintenance Free Dehydrating Breather Part no.: 686 - - - - Form your part number by selecting the individual parameters: For example: 686-10--103- Part no.: Parameter
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60
ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac II air conditioner is a vertical, wall mounted, cost effective air conditioner
Edition Perfect combination ratiopacpro Electronic P Edition kaging www clear order..biz information in the catalogue
ratiopacpro Overview... 0 Cabinets... 1 Y Desk-top cases Y Wall mounted cases... 2 Accessories for cabinets and wall mounted cases... 3 Climate control... 4 Desk-top cases... 5 06800002 Subracks/ 19" chassis...
Fresh Air Enclosure Cooling Filter Fans
763.576.3200 SPEC-00306 K763.422.2211 COOLING FRESH AIR ENCLOSURE COOLING FILTER FANS Fresh Air Enclosure Cooling Filter Fans TFP SIDE-MOUNT TFP10 215 CFM (365 m3/hr.) TFP6 140 CFM (238 m3/hr.) TFP4 55
Brochure 2012-2013.EX
VERTIGA Brochure 2012-2013.EX VERTIGA The new benchmark for design at super-low water temperatures The ultimate expression of form and function. Vertiga combines the power of Jaga Top Performers, the efficiency
COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C
COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing
The most comfortable air-conditioning systems for yachts and superyachts
The most comfortable air-conditioning systems for yachts and superyachts Chiller and self contained systems Air outlets airhandlers in a yacht INTRODUCTION TO CLION-MARINE With over 20 years of experience
Solenoid valves Type EVU
Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot
Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay
Original HVAC Units: Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue Photo Essay One fan motor draws air from the lower section of the unit,
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
7000 Series Buccaneer
The all plastic and metal construction of the - circular that combine the ease of use of a quick coupling mechanism with proven environmental sealing for signal and mains power. Designed and independently
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
LIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series
Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts
Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Aluminium Standard. Technical Data. Included in delivery
luminium Standard UL / cul Robust aluminium enclosure for mechanical engineering and automation technology Fixing options for s and mounting plates Usable in wide temperature area Technical ata aterial:
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
Knürr Smaract. Knürr Smaract. CompactRack
CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.
SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
How To Build A Low Voltage Capacitor Lvcp
Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Confort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)
CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR) Fig1. CPTR SMART CONTROL PRECISION CUSTOMIZED MANUAL OR AUTO SCR OR DIODE DRY TYPE SWITCH MODE DRY TYPE SCR OR DIODE OIL TYPE 1 INDEX PAGE 1. Cover 2. Index
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
CADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
Model: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications
COMMISSIONING OF HVAC SYSTEMS
FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
SECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
V94 BULK TAPE DEGAUSSER
TECHNICAL MANUAL Operating and Maintenance Instructions for V94 BULK TAPE DEGAUSSER V94 BULK TAPE DEGAUSSER TECHNICAL MANUAL Document No. M000208 Production Standard ZZ 009 415 WARNING To help minimise
AIR DEHUMIDIFYING 2011. Condensation drying for industry and trade
AIR DEHUMIDIFYING 2011 Condensation drying for industry and trade Condensation drying for industry and trade 2011 DH 18 domestic dehumidifiers Development, production and sales: All from a single source