DALI RC BASIC SO. Control unit Operating instructions

Size: px
Start display at page:

Download "DALI RC BASIC SO. Control unit Operating instructions"

Transcription

1 DALI RC BASIC SO Control unit Operating instructions

2

3 Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness control 5 Motion detection 5 Design 5 Installation... 6 Installation notes 6 Connection examples 7 Light control 7 Brightness control of luminaire group 1 (with one sensor) 8 Brightness control of luminaire group 1 and motion detection (with two sensors) 9 Brightness control of luminaire groups 1, 2 and 3 and expanded motion detection (with three sensors) 10 Connections 11 Testing the pushbutton wiring 11 System and fault messages 12 Behaviour after a power failure 12 Operation Symbols 13 Principle of closed-loop and open-loop control 13 Performing a reset 14 Defining the luminaire groups 14 Testing the luminaire group assignment 16 Switching on and off the luminaires 16 Changing the brightness manually 17 Storing and calling up a lighting scene 17 Locking luminaire group assignment and scene storage 18 Adjusting the switch-off delay time 18 Appendix Technical data 19 Dimensioned drawing 20 3

4 Safety DALI RC BASIC SO Safety General instructions Safety instructions The control unit must only be installed and put into operation by a qualified electrician. The applicable safety regulations and accident prevention regulations must be observed. WARNING! Exposed, live cables. Danger of electric shock! Only work on the control unit when it is de-energised. CAUTION! Destruction of the control unit and other devices through incorrect mounting! Adhere to the connection diagram. Supply the control unit via an AC power supply only. Do not route sensor and pushbutton lines together with power supply lines in the same cable. When routing DALI and power supply lines together, make sure that they are sufficiently insulated. Do not connect additional DALI supplies or DALI control units in the system to avoid exceeding the max. permissible total current of 250 ma. The DALI interface should be treated as a mains supply. Only connect DALI components to the DALI interface. Do not connect the mains supply to the DALI interface. Do not combine the control unit with a mains-voltage operated pushbutton controller. Always connect pushbuttons to a floating contact. Do not exceed the maximum total line lengths and the corresponding line crosssections. Do not exceed the maximum number of connectable components. 4 VII 2009

5 DALI RC BASIC SO Description Description Purpose and application Function Design The DALI RC BASIC SO control unit can be used for both scene-based open-loop control and daylight/presence-dependent closed-loop control. The control unit can control up to 64 DALI units (ECG or converters). The functions are operated on standard pushbuttons. Light control The control unit enables the variable formation of 4 luminaire groups whose individual brightness settings can be used to set up and store 4 scenes (lighting situations in a room). Brightness control In scene 1, the brightness of up to 3 luminaire groups can be controlled by connecting light sensors (DALI LS BASIC): The sensors measure the brightness in the area requiring control and keep it to an adjustable set value by introducing artificial light according to the amount of daylight available. Motion detection In addition, by connecting combined light and motion sensors (DALI LS/PD BASIC), all luminaire groups can be switched on and off depending on the presence of persons. The control unit is made up of the following components: Connection terminals (A) Reset button (B) Adjusting screw for switch-off delay time (C) LED display (D) Housing (E) A B A C D A E A VII

6 Installation DALI RC BASIC SO Installation Installation notes A maximum of 64 DALI units can be connected. A maximum of 6 sensors can be connected, either all on a single LS input or distributed over the inputs LS 1 to LS 3, depending on the application. If multiple light sensors are connected in parallel to an LS input, the light value is averaged. The control unit contains the power supply for the DALI interfaces and the supply voltage for the sensors. If the DALI lines are overloaded for a long period or short-circuited, the DALI interface switches to high impedance until the fault is eliminated. The green On LED goes out and the red Fault LED lights up. The fault contact is not closed in this case. The motion sensors are automatically detected when the mains voltage of the control unit is connected, but their removal is only detected after power is disconnected. The light sensors are always detected. All motion sensors connected to the PD input act in parallel (detection area extension). After the mains supply is connected, motion detection is suppressed for 1 minute. Standard pushbuttons can be used for operation (make contacts with basic insulation). To make full use of the functionality, a 5-fold pushbutton field is required (e.g. DALI WCU 5 BASIC W). The pushbuttons can be connected in parallel to be able to operate the lighting system from different locations. An optional signal lamp may be connected. Other connections are possible using the floating contact. By using DALI converters, it is also possible to transfer the functions of the control unit to existing V / V systems. 6 VII 2009

7 DALI RC BASIC SO Installation Connection examples Light control No sensor is connected. à Luminaire group 1 to 4: light control Mains voltage 230V~ 50/60Hz Signal lamp (optional) To the DALI operating devices Pushbuttons VII

8 Installation DALI RC BASIC SO Brightness control of luminaire group 1 (with one sensor) The sensor is connected to LS1 and is thus assigned to luminaire group 1. à Luminaire group 1: brightness control in lighting scene 1 à Luminaire groups 2 to 4: light control Mains voltage 230V~ 50/60Hz Signal lamp (optional) To the DALI operating devices Pushbuttons 8 VII 2009

9 DALI RC BASIC SO Installation Brightness control of luminaire group 1 and motion detection (with two sensors) The sensors are connected in parallel to LS1 and are thus assigned to luminaire group 1 (the light measurement values are averaged). The sensors are connected in parallel to the PD (more sensitive motion detection or enlargement of detection area). à Luminaire group 1: brightness control with motion detection in lighting scene 1 à Luminaire groups 2 to 4: light control with motion detection (calling up of lighting scene 1) Mains voltage 230V~ 50/60Hz Signal lamp (optional) To the DALI operating devices Pushbuttons VII

10 Installation DALI RC BASIC SO Brightness control of luminaire groups 1, 2 and 3 and expanded motion detection (with three sensors) The sensors are connected to inputs LS1 to LS3. The brightness control is thus permanently assigned to each of the luminaire groups 1 to 3. The sensors are connected in parallel to the PD (more sensitive motion detection or enlargement of detection area). à Luminaire group 1 to 3: brightness control with motion detection in scene 1 lighting à Luminaire group 4: light control with motion detection (calling up of lighting scene 1) Mains voltage 230V~ 50/60Hz Signal lamp (optional) To the DALI operating devices Pushbuttons 10 VII 2009

11 DALI RC BASIC SO Installation Connections Terminal 1/9 (DA+) 2/10 (DA ) Function DALI interface as per DALI specification Terminals 1/9 and 2/10 are internally connected Polarized Power supply for DALI units: approx. +16 V/150 ma DC (DA+), Is < 250 ma DC, max V DC, electric current limiter, overtemperature protection 3/4 (0V) Sensor signal ground, terminals internally connected 5/6/7 (PD) Sensor motion signal, < 5 V DC, terminals internally connected 8/16 (Vcc) Sensor supply, approx. +10 V/15 ma DC, terminals internally connected 11/12 (0V) Sensor signal ground, terminals internally connected 13/14/15 (LS1, LS2, LS3) Sensor light measurement value (analog), < 5 V DC 17/25 (fault) Fault contact, floating relay contact (make contact), max. 250 V/5 A, µ contact gap: function switching, no reliable isolation 18/26 NC (may not be used) 19/27 (L) Power supply, terminals internally connected 20/28 (N) Power supply, terminals internally connected 21/22/23/24/29 (T1 T4, master) Pushbutton inputs (make contacts), < 5 V DC 30/31/32 (0V) Pushbutton signal ground, terminals internally connected Testing the pushbutton wiring Proceed as follows: Step Task Result 1 Briefly press the reset button. The test mode is active. The brightness of all luminaires is reduced to a minimum. 2 Press button 1 to 4. Button 1: luminaires flash 1x Button 2: luminaires flash 2x Button 3: luminaires flash 3x Button 4: luminaires flash 4x 3 Press the central button. The test mode is ended. All luminaires switch to maximum brightness. VII

12 Installation DALI RC BASIC SO System and fault messages The system and fault messages are displayed using the LED located in the device or optionally via a signal lamp connected to the fault contact, or are forwarded to a higher level system. LED State Meaning Green "On" LED Yellow "Send" LED Red "Fault" LED Flashes On On Flashes On Lock mode is active. Control unit is operational. Communication on DALI interface. No DALI units are connected, DALI lines are disrupted or short-circuited. The fault contact switches at the same rate. The lamp of an active DALI ECG is faulty. The fault contact is closed. Behaviour after a power failure If the power supply to the control unit fails, connected DALI units that are still supplied with power are switched to maximum brightness (see also the corresponding manufacturer information). When power returns, the control unit automatically restores the lighting system to its status prior to the failure. 12 VII 2009

13 DALI RC BASIC SO Operation Operation Symbols Switch on Switch off Pushbutton on the luminaire Luminaire on Luminaire off Brightness with automat. control Short press (< 0.5 s) Long press (0.5 4 s) Principle of closed-loop and open-loop control Luminaire OFF Motion? no yes Scene 1 no no no no no Button 1 pressed? Button 2 pressed? Button 3 pressed? Button 4 pressed? yes yes yes yes Scene 2 Scene 3 Scene 4 Artificial light required? no min. 10 min yes Motion? no 16 s* min min yes * If motion is detected while the lighting system is being dimmed down (approx. 16 seconds), the last lighting setting is restored. VII

14 Operation DALI RC BASIC SO Performing a reset In the basic setting, all luminaires are assigned to luminaire group 1 and scenes 1 to 4 are predefined. Note: In the following cases, the control unit automatically resets the system when the mains voltage is applied: When the system is being installed for the first time. If a luminaire has not yet been assigned to a group. Proceed as follows: Step Task Result 1 Switch off the mains supply of the control unit and wait for the "On" LED to go out. 2 Switch the mains supply back on while pressing the reset button. 3 When the red "Fault" LED goes out, release the reset button. All group assignments and scene settings are cleared. Defining the luminaire groups Note: Light sensor inputs LS1 to LS3 are permanently assigned in the control unit to luminaire groups 1 to 3. When defining the luminaire groups, ensure that they are arranged according to the light sensors (luminaire group 1 for the light sensors on LS1, etc.). A light sensor cannot be connected to luminaire group 4 and brightness control is not possible. Proceed as follows: Step Task Result 1 If necessary, unlock the luminaire group assignment function; see "Locking luminaire group assignment and scene storage". 2 Press the central button, button 1 and button 2 simultaneously and hold for approx. 5 s. All luminaires flash. 14 VII 2009

15 DALI RC BASIC SO Operation Step Task Result 3 Within the next 10 s, press the central button gain and hold for approx. 5 s. 4 Press one of the pushbuttons 1 to 4, corresponding to the required group. Note: Each DALI unit can only be assigned to one group. The brightness of all luminaires is reduced to a minimum. The control unit searches for existing DALI units. When a unit is identified, its lamp begins to flash. Note: The search for DALI units can take several seconds. The order in which the units are found is random. The flashing luminaire is assigned to the corresponding luminaire group 1 to 4. The brightness of the luminaires that already belong to the selected luminaire group is set to the maximum value, while the luminaire of the unit being assigned continues to flash. The luminaires of all other units remain at minimum brightness. 5 If necessary, change the assignment by pressing another button 1 to 4. 6 Press the central button. The assignment to a luminaire group for the current unit is stored. All luminaires are set to minimum brightness again. The control unit automatically searches for the next DALI unit. 7 Repeat steps 3 to 5 until all luminaires are assigned. After the last unit is assigned, all luminaires flash 1x. The group assignment mode is ended automatically. Note: Changes in the luminaire group assignment are not yet included in the existing lighting scenes. Therefore, the lighting scenes need to be adjusted and stored after the luminaire group assignment is changed. 8 If necessary, test the luminaire group assignment; see "Testing the luminaire group assignment". VII

16 Operation DALI RC BASIC SO Step Task Result 9 If necessary, lock the luminaire group assignment function again; see "Locking luminaire group assignment and scene storage". When adding or removing DALI units, the entire procedure needs to be repeated and the existing assignments of all units that have already detected must each be confirmed via the central button. Testing the luminaire group assignment Immediately after the groups are assigned (see Defining the luminaire groups ), the system goes into group test mode. Proceed as follows: Step Task Result 1 Press pushbuttons 1 to 4. 2 Press the central button. The luminaires of the corresponding luminaire groups 1 to 4 flash 1x. The group test mode is ended. Switching on and off the luminaires Via short press. All luminaires: central button. Luminaire groups 1 to 4: Press and hold pushbuttons 1 to 4 while pressing the central button at the same time. 16 VII 2009

17 DALI RC BASIC SO Operation Changing the brightness manually Via long press. Each repeated long key button press causes a toggle between increased brightness and decreased brightness. All luminaires: central button. Luminaire groups 1 to 4: Press and hold pushbuttons 1 to 4 while pressing the central button at the same time. Storing and calling up a lighting scene Pushbuttons 1 to 4. Proceed as follows to store lighting scenes: Step Task 1 Set the brightness of the luminaire groups; see "Changing the brightness manually". 2 Press the desired button for at least 5 seconds. 3 Confirmation: luminaires flash. Note: The brightness values stored in lighting scene 1 (button 1) are the setpoints for the brightness control. The lighting scene storage function can be locked; see Locking luminaire group assignment and scene storage. To call up a lighting scene: Use a short press. VII

18 Operation DALI RC BASIC SO Locking luminaire group assignment and scene storage Luminaire group assignment and scene storage can be locked individually or globally. This prevents these system settings from being changed accidentally. Note: A reset clears the locks. Proceed as follows: Step Task Result 1 Press the reset button for approx. 10 s. Lock mode is active. The green "On" LED flashes. 2 Press the reset button repeatedly until the required setting is displayed by the LEDs; see the table below. 3 To store the settings: Press the reset button for approx. 10 s. Note: To discard the settings and end the lock mode without storing: Press any button. All LEDs flash 1x. The setting is stored and lock mode is ended. Yellow "Send" LED Red "Fault" LED Lock mode Off Off Luminaire group assignment and scene storage is available. On Off Luminaire group assignment is locked. Off On Scene storage is locked. On On Luminaire group assignment and scene storage is locked. Adjusting the switch-off delay time Switch-off delay time if no motion is detected. Turn the adjusting screw on the sensor to the required setting: To the left: shorter (min. 1 min) To the right: longer (max. 32 min) 18 VII 2009

19 DALI RC BASIC SO Appendix Appendix Technical data Operating voltage Power consumption Fuse Connection terminals Maximum total length of DALI lines depending on line crosssection Maximum total length of sensor lines Design Mounting 230 V AC/ Hz (no DC operation) Approx. 4 9 W (depending on load) Device and fault contact, external, max. 6 A Screw terminals Solid: 2 x mm 2 Stranded wire with sleeve: 2 x mm 2 The DALI interface, pushbutton inputs and sensor terminals have basic insulation but no safety extralow voltage. 2x 0.5 mm²: 100 m 2x 0.75 mm²: 150 m 2x 1.0 mm²: 200 m 2x 1.5 mm²: 300 m 100 m Insulated casing Operating temperature 0 C C Protection type IP 20 Protection class Pollution severity Weight Dimensions (L x W x H) Snap-on fastener for mounting on DIN rails II (double insulated) 2 (dry, not conductive) Approx. 550 g 140 x 90 x 61 mm (8 HP) VII

20 Appendix DALI RC BASIC SO Dimensioned drawing Conformity with the relevant EU directives is confirmed by the CE symbol. 20 VII 2009

21 VII 2009 DALI_RC_BASIC_SO_0907en_we1.01.indd OSRAM GmbH Kunden Service Center Customer-Service-Center (CSC) Steinerne Furt Augsburg Germany Tel : +49 (0) (kostenpflichtig / charges apply) Fax.: +49 (0)

Operating instructions IV / 2007

Operating instructions IV / 2007 General Operating instructions IV / 2007 Contents General Installation Application and function Application and function... 2 Safety information... 2 Design and dimensions... 3 Wiring diagram... 3 Installation

More information

Operating instructions

Operating instructions Operating instructions DALI BASIC lighting control system Type: DALI RC BASIC SO OSRAM GmbH Hellabrunner Str. 1 D 81536 Munich Tel.: +49 89 6213 0 Fax: +49 89 6213 2020 Customer Service Center (KSC) Germany

More information

Operating instructions II / 2004

Operating instructions II / 2004 Operating instructions II / 2004 Light and presence sensor TOUCH DIM LS/PD LI OSRAM GmbH Costumer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany www.osram.com www.osram.de Tel. : (+49)

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable

More information

Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI

Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI OSRAM GmbH Hellabrunner Str. 1 D-81536 Munich Tel.: +49 (0) 89 6213 0 Fax: +49 (0) 89 6213 2020 Customer Service Center (KSC)

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

Inwall 4 Input / 4 Output Module

Inwall 4 Input / 4 Output Module Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Product manual ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes

More information

Transmitter Actuator 230V wave UP 560. Operation

Transmitter Actuator 230V wave UP 560. Operation Transmitter ctuator 230V wave UP 560 5WG3 560-201 Product- and pplication Description Diagram The transmitter actuator 230V wave UP 560 (Diagram ) is a flush-mounted device with radio communication for

More information

MINI MCR-SL-R-UI(-SP)

MINI MCR-SL-R-UI(-SP) Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts

More information

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5 T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,

More information

WD-AMX Water Detection Controllers

WD-AMX Water Detection Controllers Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation

More information

basicdim DGC Compact control module

basicdim DGC Compact control module luxctrol lighting control sstem DGC Compact control module Product description Compact dimensions for luminaire installation For up to 0 DSI or LI ballasts ( per output channel) LI IN input LI/DSI output

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

instabus KNX / EIB System System E F G H

instabus KNX / EIB System System E F G H Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA

More information

How To Use A Power Supply On A Powerline 2.2 (Ai)

How To Use A Power Supply On A Powerline 2.2 (Ai) KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang

More information

Electrical connection

Electrical connection (I)GSU 14B Ultrasonic Label Fork Dimensioned drawing Part No. 501 09234 4mm 12-30 V DC 4 m/s Ultrasonic forked sensor for universal application Large mouth width, hence also suitable for booklets or fan-fold

More information

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions Compact presence detector Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

Tebis KNX Product Documentation. DALI Gateway. Date of issue: 21.11.2006 64540020.111. Order no. 6 4540 020 Page 1 of 131

Tebis KNX Product Documentation. DALI Gateway. Date of issue: 21.11.2006 64540020.111. Order no. 6 4540 020 Page 1 of 131 Tebis KNX Product Documentation DALI Gateway Date of issue: 21.11.2006 64540020.111 Order no. 6 4540 020 Page 1 of 131 Tebis KNX Product Documentation Table of Contents 1 Product definition... 3 1.1 Product

More information

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004 Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

Operating instructions Switching amplifier for fibre optics. OBF5xx 704876 / 00 08 / 2010

Operating instructions Switching amplifier for fibre optics. OBF5xx 704876 / 00 08 / 2010 Operating instructions Switching amplifier for fibre optics OBF5xx 70876 / 00 08 / 00 Contents Preliminary note. Symbols used Functions and features. Applications Installation. Attaching the fibre optics

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

Operating instructions Optical distance sensor O1D100 O1D103 704991 / 00 08 / 2012

Operating instructions Optical distance sensor O1D100 O1D103 704991 / 00 08 / 2012 Operating instructions Optical distance sensor UK O1D100 O1D103 704991 / 00 08 / 2012 Contents 1 Preliminary note4 1.1 Symbols used 4 1.2 Warning signs used 4 2 Safety instructions 4 3 Functions and features

More information

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay

More information

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 300 Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, 14 80 W ECO T5

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, 14 80 W ECO T5 EL PCA ECO lp Y II, 1 80 W ECO Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DALI or DSI signal, switchdim

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Shunt lock function 3066

Shunt lock function 3066 Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

PERCEDOS. Instruction Manual/Technical Information PERCEDOS

PERCEDOS. Instruction Manual/Technical Information PERCEDOS PERCEDOS Instruction Manual/Technical Information PERCEDOS Function description: PERCEDOS is a portable protective system (IC-RCD*) including communication interface to the electrical vehicle and intended

More information

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product! EPSOLAR LS0512R / LS0524R Solar Light Controller INSTRUCTION MANUAL Please read this manual carefully before using the product! LandStar LS0512R / LS0524R Solar Light Controller Nominal system voltage

More information

GAE953 Electrical Alarm Unit 19" with Indicator

GAE953 Electrical Alarm Unit 19 with Indicator Master Instruction 08.95 MI EIO2211 A-(en) GAE953 Electrical Alarm Unit 19" with Indicator The electrical alarm unit GAE953 gives a signal when one or two set alarm values have been exceeded. Input signals

More information

ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1

ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................

More information

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Contents 1 Preliminary note 3 1.1 Symbols used 3 1.2 Warning signs used 3 2 Safety instructions

More information

Light scene push button 8gang comfort flush-mounted 751688xx

Light scene push button 8gang comfort flush-mounted 751688xx 751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional

More information

Smart DeviceNet Remote I/O Terminals

Smart DeviceNet Remote I/O Terminals Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

SECURITY SYSTEM ADP-CAN

SECURITY SYSTEM ADP-CAN INSTALLATION INSTRUCTION SECURITY SYSTEM ADP-CAN Introduction Motorcar security system ADP-CAN is for motorcars provided with CAN net. It is for the work with the motorcar factory security systems or remote

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring

More information

IO-RM3 3-Stage Relay Module

IO-RM3 3-Stage Relay Module Page 1 of 6 IO-RM3 3-Stage Relay Module Features: Benefits: Link selectable modes binary, heat/cool, staged or sequenced On/Off/Auto links for ease of commissioning DIN Rail mounting Fault finding LED

More information

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series Product description Independent dimmable LED control gear Constant current LED control gear Output current adjustable between 900 1,750 ma Max. output

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description

More information

Safety Manual BT50(T) Safety relay / Expansion relay

Safety Manual BT50(T) Safety relay / Expansion relay Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

User Guide. Model 380260 Insulation Tester / Megohmmeter

User Guide. Model 380260 Insulation Tester / Megohmmeter User Guide Model 380260 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011 Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5 F ballasts T PCA T EXCE oneall lp Y, x1/ W and x1/ W EXCE T Product description Processor-controlled ballast with y inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via

More information

COLOR VIDEO DOOR PHONE CDV-71BE/D

COLOR VIDEO DOOR PHONE CDV-71BE/D COLOR VIDEO DOOR PHONE CDV-71BE/D 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com Printed

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

Operating instructions. Monitor FR-1 / FR-1N 7390339 / 01 02 / 2011

Operating instructions. Monitor FR-1 / FR-1N 7390339 / 01 02 / 2011 Operating instructions Monitor FR-1 / FR-1N UK 1 2 3 4 5 6 7 8 9 10 11 12 7390339 / 01 02 / 2011 CH1CH2 CH3CH4RUNPRGTST KEY 13 14 15 16 17 18 19 20 21 22 23 24 Contents 1 Preliminary note 4 1.1 Symbols

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

PHOENIX CONTACT - 2012-12-14. Features

PHOENIX CONTACT - 2012-12-14. Features Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional

More information

ABB i-bus KNX Security Terminals MT/U 2.12.2, MT/S 4.12.2M and 8.12.2M Product Manual

ABB i-bus KNX Security Terminals MT/U 2.12.2, MT/S 4.12.2M and 8.12.2M Product Manual ABB i-bus KNX Security Terminals MT/U 2.12.2, MT/S 4.12.2M and 8.12.2M Product Manual Contents Contents Page 1 General 3 1.1 Use of the product manual...3 1.1.1 Structure of the product manual...3 1.1.2

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000 Security Alarm Central Unit 3 4 Technical KNX Alarm central unit EAM 4000 ETS-product family: Alarm system Product type: Alarm central unit The alarm central unit is a modern alarm system using the KNX

More information

mecotron Safety relay ESTOP-2 For emergency stop monitoring

mecotron Safety relay ESTOP-2 For emergency stop monitoring E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated

More information

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation

More information

AUTODIALLER / QUICKDIALLER - SA132

AUTODIALLER / QUICKDIALLER - SA132 AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING

More information

Infrarot-Bewegungsmelder IP44

Infrarot-Bewegungsmelder IP44 Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion

More information

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1 BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Product and Application Description

Product and Application Description Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design

More information

Inwall Room Temperature Unit

Inwall Room Temperature Unit Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

RRV934. Multi-controller. Synco living

RRV934. Multi-controller. Synco living s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard

More information

Highly flexible the right KNX/DALI gateway for every requirement

Highly flexible the right KNX/DALI gateway for every requirement The worldwide standard for home and building control Highly flexible the right / gateway for every requirement Integrating lighting control into building control safely, efficiently and comfortably with

More information

DLP-PU/E Instruction Manual

DLP-PU/E Instruction Manual Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

More information

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB , GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

UM-X Field display for continous level sensors

UM-X Field display for continous level sensors Technical Documentation Field display for continous level sensors 10/2007 Edition: 1 Item No.: 207120 FAFNIR GmbH Bahrenfelder Str. 19 D-22765 Hamburg Telephone: +49 (0)40-39 82 07-0 Fax: +49 (0)40-3 90

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information