Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201
|
|
|
- Justin Townsend
- 9 years ago
- Views:
Transcription
1 Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC C001
2 ABB STOTZ-KONTAKT GmbH CDC C001
3 Low Voltage Products and Systems We ensure safety and comfort for everyday life by bringing electric power to domestic appliances, lighting and heating. Through our comprehensive range of enclosures, line protection equipment, wiring accessories and various other components to complete any electrical installation we cover the full spectrum of equipment required for control and protection of all domestic and residential instalations. With this EIB system all electrical functions in a home can now be programmed and remotely controlled. Domestic and residential buildings Commercial and industrial buildings All over the world office buildings, hospitals, hotels, public buildings, shopping centers, sport complexes and city lighting projects are equipped with ABB Low Voltage Products and Systems. From switchboard to light switch we cover the complete range of equipment required for control and protection of electrical installations. Architects, consultants, builders and contractors appreciate the performance/cost ratio provided by our products. They have made ABB a well known reference for high quality and extremely reliable electrical equipment. ABB STOTZ-KONTAKT GmbH 3 CDC C001
4 Installation contactors Type ESB.. Contents Installation contactors Ordering details... 4 Technical data... 5 Switching lamp loads... 7 Ordering details for accessories Location of the connection terminals... 8 Approvals and certificates... 8 SST Application Automation processes in building wiring and installation can be implemented with installation contactors. They are used chiefly for switching and controlling lighting systems, heating systems, ventilation systems, pumps, heating pumps and other building automation actuators. Geräte für Schalttafeleinbau auf Tragschienen (35 mm) nach DIN EN 50 0 Installation depth: System 68 mm Installation width: 1, and 3 modules (1 module = mm) Colour: grey, RAL 7035 suitable for the ABB system pro M Advantages hum-free solenoid drive low-noise switching switching position indicator integrated coil protective circuit attachable auxiliary switch overvoltage protection for the solenoid coil up to 5 kv high making/breaking capacity and long service life quick fastening with latching slide large connections with open box terminals shock-hazard protection to VDE 0106, Part 100 Construction Type ESB 0 operates with an AC solenoid system. Types ESB 4, 40 and 63 feature a DC solenoid actuator and are thus hum-free. The noise during switching on is hardly audible compared with an AC solenoid. An integrated diode jumper allows connection to AC voltage. The incorporated varistor protects the coil against remote lightening strikes and overvoltages of up to 5 kv. In addition, it limits the interference voltage peaks of the solenoid system. The contactors can therefore be combined with programmable logic controllers. There is no need for a coil protective circuit. The solenoid system is provided with radio interference suppression. Overvoltage peaks may cause a current of max. 00 A resp. an energy of max. 4 J or 10 6 x a current of 5 A resp. an energy of max J with normal wave (8/0 s). All switching elements of the contactors can be used as main contact elements or as auxiliary contact elements (see also technical data). The contacts are not positively driven, and NO and NC contacts can therefore overlap. On Types ESB 4, 40 and 63, a two-pole auxiliary switch, Type EH 04 (1/ module width) can be attached. This auxiliary switch must be used for switching control signals. Contactors ESB 0, 4 and 40 are also available as "EN" devices with integrated manual switch, e.g. for "day/night" application. Data sheet on request. 4 ABB STOTZ-KONTAKT GmbH CDC C001
5 Installation contactors ESB.. Ordering details Accessories IEC EN IEC 1095 EN Anschlußbezeichnungen Contactor type Rated operating voltage Order code bbn Weight Pack. Contact piece unit complement 50 Hz 60 Hz Product No. EAN kg piece ESB 0 NO SST S/1 ESB V 14 V GH E R NO 4 V V GH E R V 48 V GH E R V 55 V GH E R V V GH E R V 55 V GH E R V V GH E R V GH E R ESB V 14 V GH E31 10 R NC 4 V V GH E31 10 R V 48 V GH E31 10 R V 55 V GH E31 10 R V V GH E31 10 R V 55 V GH E31 10 R V V GH E31 10 R V GH E31 10 R ESB V 14 V GH E R NO 4 V V GH E R NC 4 V 48 V GH E31 10 R V 55 V GH E R V V GH E R V 55 V GH E R V V GH E R V GH E R ESB V GH E R NO 4 V AC GH E R V Hz GH E R V or GH E R V DC GH E R V GH E R V GH E R ESB V GH E39 10 R NC 4 V AC GH E39 10 R V Hz GH E39 10 R V or GH E39 10 R V DC GH E39 10 R V GH E39 10 R V GH E39 10 R ESB 4-1 V GH E R NO 4 V AC GH E R NC 4 V Hz GH E R V or GH E R V DC GH E R V GH E R V GH E R ESB V GH E R NO 4 V AC GH E R NC 4 V Hz GH E R V or GH E R V DC GH E R V GH E R V GH E R ESB V GH E R NO 4 V AC GH E R NC 4 V Hz GH E R V or GH E R V DC GH E R V GH E R V GH E R ESB V GH E R NO 4 V GH E R V AC GH E R V Hz. GH E R V or GH E R V DC GH E R V GH E R V GH E R ESB V GH E R NO 4 V GH E R V AC GH E R V Hz GH E R V or GH E R V DC GH E R V GH E R V GH E R Other voltages on request. "Day/night" installation contactors, Type EN 0, EN4, EN 40 on request. Only delivery from ABB-Control France. 1 or NC up to max. 30 A (AC-1) possible. ESB 0 NC ESB 0 1 NO 1 NC ESB 4 ESB 40 ESB 63 4 NO SST S/3 SST S/ SST S/4 ESB 4 3 NO 1 NC SST S/5 ESB 4 NC NO SST S/6 ESB 4 4 NC EH 04-0 NO EH NO 1 NC SST S SST 09 9 S SST S/7 ABB STOTZ-KONTAKT GmbH 5 CDC C001
6 Installation contactors ESB.. Technical data IEC EN IEC 1095 EN Rated operating currents and power ratings ESB 0 SST R AC-1 / AC-7a ESB 0 ESB 4 ESB 40 ESB 63 Rated operating current I e (NO) 0 A 4 A 40 A 63 A Rated operating current I e (NC) 0 A 4 A 30 A 30 A current paths connected in parallel permit a 1.6-fold increase in rated operating current I e. Rated operating power (NO) 30 V single-phase 4.0 kw 5.3 kw 8.8 kw 13.8 kw 30 V 3-phase 9.0 kw 15. kw 4.0 kw 400 V 3-phase 16.0 kw 6.0 kw 41.0 kw AC-3/AC-7b Switching motors Rated operating current I e (NO) 9 A 9 A A 30 A Rated operating current I e (NC) 9 A 6 A Rated operating power (NO) 30 V single-phase 1.3 kw 1.3 kw 3.7 kw 5.0 kw 30 V 3-phase. kw 5.5 kw 8.0 kw 400 V 3-phase 4.0 kw 11.0 kw 15.0 kw ESB 4 SST R DC-1/DC-3 Switching DC with NO contacts (NO) Rated DC-1 (L/R 1 ms) DC-3 (L/R ms) operating 1 current current paths 3 current paths 1 current current paths 3 current paths Type voltage U e path in series in series path in series in series ESB 4 4 V DC 4.0 A 4.0 A 4.0 A 16.0 A 4.0 A 4.0 A 48 V DC 1.0 A 4.0 A 4.0 A 8.0 A 18.0 A 4.0 A 60 V DC 17.0 A 4.0 A 4.0 A 4.0 A 14.0 A 4.0 A 110 V DC 7.0 A 16.0 A 4.0 A 1.6 A 6.5 A 16.0 A 0 V DC 0.9 A 4.5 A 13.0 A 0. A 1.0 A 4.0 A ESB 40 4 V DC 40.0 A 40.0 A 40.0 A 19.0 A 40.0 A 40.0 A 48 V DC 3.0 A 40.0 A 40.0 A 10.0 A 0.0 A 40.0 A 60 V DC 18.0 A 3.0 A 40.0 A 5.0 A 16.0 A 34.0 A 110 V DC 8.0 A 17.0 A 30.0 A 1.8 A 7.0 A 18.0 A 0 V DC 1.0 A 5.0 A 15.0 A 0.3 A 1.1 A 4.5 A ESB 40/ESB 63 SST R ESB 63 4 V DC 50.0 A 63.0 A 63.0 A 1.0 A 44.0 A 63.0 A 48 V DC 5.0 A 43.0 A 63.0 A 11.0 A.0 A 47.0 A 60 V DC 0.0 A 35.0 A 60.0 A 5.5 A 18.0 A 38.0 A 110 V DC 9.0 A 19.0 A 33.0 A.0 A 8.0 A 1.0 A 0 V DC 1.1 A 5.5 A 17.0 A 0.3 A 1. A 5.0 A ESB 4 + EH 04 SST R DC-1/DC-3 Switching DC with NC contacts (NC) Rated DC-1 (L/R 1 ms) DC-3 (L/R ms) operating 1 current current paths 3 current paths 1 current current paths 3 current paths Type voltage U e path in series in series path in series in series ESB 4 4 V DC 14.5 A 4.0 A 4.0 A 6.3 A 11.0 A 19.0 A 48 V DC 7.5 A 1.5 A.0 A 3.1 A 5.4 A 9.4 A 60 V DC 4.5 A 10.0 A 17.5 A.0 A 4.3 A 7.5 A 110 V DC 1.6 A 4.4 A 9.5 A 0.7 A 1.9 A 4.1 A 0 V DC 0. A 1.4 A 3.8 A 0.1 A 0.6 A 1.6 A Contactor type Order code Rated operating Rated operating current voltage EN V GHE R A 4 V EN V GHE R A V EN V GHE R A V EN V GHE R A 4 V SST EN V GHE R A V EN V GHE R A 30 V EN 4 Switching lamp loads, see Page 8. 6 ABB STOTZ-KONTAKT GmbH CDC C001
7 Installation contactors ESB.. Technical data of ESB.. and auxiliary switches IEC EN IEC 1095 EN Millions of operating cycles Contact member service life AC-1/400 V/3-phase for ESB 4, 40, 63 AC-1/30 V/single-phase for ESB ESB 0 ESB 4 ESB 40 ESB , SST K Breaking current [A] ESB 0 ESB 4 ESB 40 ESB 63 Rated insulation 400 V 500 V 500 V 500 V voltage U i Rated operation 50 V 440 V 440 V 440 V voltage U e Short-circuit protection Back-up fuse, Type "gl/gg" 0 A 35 A 63 A 80 A Limiting short-time current 10 s at ambient temperature < 40 C, in free air, from cold state 7 A 7 A 176 A 40 A Ohmic loss 1.0 W 1.5W 3.0 W 6.0 W per current path at I e (AC-1, AC-7a) Millions of operating cycles 1 0,8 0,6 0,5 0,4 0,3 0, AC-3/400 V/3-phase for ESB 4, 40, 63 0,1 0,08 0,06 0,05 0,04 0,03 0,0 0,01 ESB 4 ESB 40 ESB , ,1, 3 4 7, SST K 80 Breaking current [A] Switching capacity [kw] Contact member service life and max. switching frequency Service life mechanical 1 million 1 million 1 million 1 million electrical at AC-1 / AC-7a at AC-3 / AC-7b Max. switching frequency AC-1 / AC-7a 300 operations/hour AC-3 / AC-7b 600 operations/hour Permissible mains frequency Hz Min. making/breaking capacity Characteristics of the solenoid system Operating range of solenoid coil % U c 17 V / 00 ma Reliable switch-off between % U c % U c Frequency range 50/60 Hz Hz AC or DC Relative duty ED 100% Dimensions in mm Power consumption of the solenoid coil pick-up 8.0VA, 5.0W 4.0VA, 4.0W 5.0VA, 5.0W 65 VA, 65 W holding 3.VA, 1.W 4.0VA, 4.0W 5.0VA, 5.0W 4. VA, 4. W On delay 1 ms < 40 ms Off delay 1 ms < 40 ms Permissible 5 -C to C Ambient temperature If several contactors are mounted adjacently and the On time is longer than one hour, every second contactor needs a distance piece, Type ESB-DIS (1/ module). This is not necessary at an ambient temperature 40 C or on Type ESB 0. Connection cross-sections Main conductor max. mm 1 x 10 or x 4 1 x 5 or x 10 min. mm 1 x x 1.5 Coil mm 1 x 4 or x.5 Type ESB 0 ESB 4 ESB 40 ESB 63 EH 04 SST M Overall width A 1 module (18.0 mm) modules (36.0 mm) 3 modules (54.0 mm) 3 modules (54.0 mm) 0.5 module ( 9.0 mm) Auxiliary switch EH 04 Thermal continuous current I th = 6 A Rated operating current I e at AC-15 for U e < 40 V AC 4 A < 415 V AC 3 A < 500 V AC A Minimum making/breaking capacity > 17 V / > 5 ma ABB STOTZ-KONTAKT GmbH 7 CDC C001
8 Installation contactors ESB.. Technical data Switching lamp loads IEC EN IEC 1095 EN Switching lamp loads Please note the following: The following table shows the number of lamps which can be connected per circuit at 30 V/50 Hz. If the specified capacitor load is exceeded, this may result in admissibly high peak inrush currents. Other factors which influence the magnitude of peak inrush currents are as follows: Length and cross-section of installed supply cables Type of electronic ballast units Lamp make The following lamp load table thus contains non-binding guideline values. Lamp type Lamp data Permissible number Caof lamps per circuit pa- (30 V, 50 Hz) citor I n in the case of contactor type load Watt A ESB ESB ESB ESB in F Incandescent lamps Fluorescent lamps, p.f. uncorrected and series p.f. correction Lead-lag circuit x 0 x 0.13 x x 6 x 85 x 140 x 40 x 0. x 17 x 0 x 65 x 105 x 58 x 0.3 x 10 x 1 x 40 x 65 x 65 x 0.34 x 10 x 1 x 40 x 65 x 115 x 0.65 x 4 x 5 x 18 x 8 x 140 x 0.75 x 4 x 5 x 18 x 8 Parallel p.f. correction High-pressure mercury-vapour lamps p.f. uncorrected / V Parallel p.f. correction / V Lamps with EVG for Permissible number of electronic ballast units per circuit elektronic Watt (30 V, 50 Hz) ballast 1 x units (EVG) x x x x x Lamp type Lamp data Permissible number Caof lamps per circuit pa- (30 V, 50 Hz) citor I n in the case of contactor type load Watt A ESB ESB ESB ESB in F Halogen metal-vapour lamps, p.f. uncorrected / / V Parallel p.f. correction / / V Low-pressure mercury-vapour lamps p.f. uncorrected Parallel p.f. correction High-pressure sodium-vapour lamps p.f. uncorrected Parallel p.f. correction Transformers Transformers Permissible number of transformers per circuit for for (30 V, 50 Hz) halogen low-volt lamps Watt ABB STOTZ-KONTAKT GmbH CDC C001
9 Installation contactors ESB.. Accessories, location of the connection terminals Approvals and certificates IEC EN IEC 1095 EN Accessories EH 04 SST R ESB-PLK-4 SST 319 R ESB-DIS SST 3069 R Aux. switches NO EH 04-0 GH E R NO + 1 NC EH GH E R Distance ESB-DIS GH E R piece Sealing ESB-PLK 4 GH E R covers ESB-PLK 40/63 GH E R Time relays ETD4 On request On-delayed Mounting onto ESB 0 not possible Location of the connection terminals Dimensions in mm ESB 0 ESB 4 ESB 40/63 EH 04 Coil terminal Main terminal Main terminal Coil terminal 1 x 10 mm x 4 mm c = 1,5 Nm 1 x 4 mm x,5 mm c = 0,9 Nm 9,6 Coil terminal Main terminal Main terminal Coil terminal 1 x 10 mm x 4 mm c = 1 Nm 1 x 4 mm x,5 mm c = 0,9 Nm 6 10 Coil terminal Main terminal Main terminal Coil terminal 1 x 5 mm x 10 mm c =,5 Nm 1 x 4 mm x,5 mm c = 0,9 Nm Designation Type Order code bbn Weight Pack. Abbreviation per unit EAN piece kg piece 39,5 15,5 SST Z SST Z 7 SST Z 64 Connection screws ESB 0 ESB 4 ESB 40 / 63 EH 04 D max. Pozidrive D max. Pozidrive D max. Pozidrive D max. Pozidrive Size Size Size Size Pozidrive Main connection Connections 5 1 Coil Approvals and certificates Device type Approvals Ships' classification societies Test mark Abbreviation Validity SEV DEMKO NEMKO SEMKO EL.Inspect. CEBEC CSA UL BV GL LRS DNV Switzerland Denmark Norway Sweden Finland Belgium Canada USA Czech. Rep. France France Germany Great Britain Norway ESB 0 ESB 4 ESB 40 ESB 63 Devices are approved. Devices have been submitted for approval or it is planned to submit them for approval. For NO contacts and control voltages 4 V and 30 V. ABB STOTZ-KONTAKT GmbH 9 CDC C001
10 Notes 10 ABB STOTZ-KONTAKT GmbH CDC C001
11 ABB STOTZ-KONTAKT GmbH 11 CDC C001
12 Brocure No.: CDC C001 Printed in the Federal Republic of Germany (11/03 3 GVD) Subject to change abb ABB STOTZ-KONTAKT GmbH P.O. Box Heidelberg Germany Phone: +49 (0) Fax: +49 (0) [email protected] 1 ABB STOTZ-KONTAKT GmbH CDC C001
Technical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
Catalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
Manual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
Technical Catalogue. Mini Contactors. Type B 6, B 7
Technical Catalogue Mini Contactors Type B 6, B 7 Mini contactors B 6/4 kw; B 7/5.5 kw Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU Contents Mini contactors
BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Pluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
System pro M compact Miniature Circuit Breaker S 200/S 200 M
Data Sheet System pro M compact Miniature Circuit Breaker S 200/S 200 M 2CDC021023S0012 2CDC021038S0012 The miniature circuit breakers of the System pro M compact series S 200 and S 200 M provide state-of-the-art
ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011
, 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011
Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
ABB i-bus KNX Switch Actuators SA/S Product Information
ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,
ESB and EN installation contactors Application handbook
ESB and EN installation contactors Application handbook 2 2CDC103022M0201 Content 1 Basic function of installation contactors 4 2 Modular DIN rail components 5 3 ESB/EN Installation contactors 6 4 Technical
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
Type: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
ABB i-bus KNX Switch Actuators SA/S Product Information
ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
Type: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
ABB i-bus KNX SA/S Switch Actuators Product Manual
ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
Analog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection
Technical data RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection When connecting aluminium conductors ensure that the contact surfaces of the conductors
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
PSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
Actuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
Relés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
Low Voltage Products. Switches Automatic Transfer Switches
Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
Switching Devices Contactors and Contactor Assemblies Special Applications
Switching Devices Contactors and Contactor Assemblies Special Applications Price groups PG 1B, 1H /2 Introduction Contactors for special applications / SIRIUS 3RT1 contactors for resistive loads (AC-1),
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
60 Series - General purpose relays 6-10 A. Features 60.12 60.13
Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Cable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
Technicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring
FP2 Relay. The Best Relaytion
The Best Relaytion 2 pole telecom / signal relay Through Hole Type (THT) Polarized. Relay types: non-latching with1 coil latching with 1 coil latching with 2 coils Features Telecom / signal relay (dry
Manual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting
Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8
3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX Data Logging Unit BDB/S 1.1 Intelligent Installation Systems ABB This manual describes the function of the Data Logging Unit BDB/S 1.1. Subject to changes and errors excepted.
Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches
Siemens AG 2014 Switching Devices /2 Introduction /5 5TE control switches / 5TE4 pushbuttons /11 5TE5 light indicators /13 5TE On/Off switches /20 5TE DC isolators /22 5ST busbars for modular installation
Control Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
MULTIFUNCTION TIME RELAY CRM-93H
4 MULTIFUNCTION TIME RELAY CRM-93H - 10 functions Features: Universal supply voltage AC/DC 12-240V 10 functions: - 5 time functions controlled by supply voltage - 4 time functions controlled by control
Maximum Demand Control
Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility
Vario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
ABB i-bus KNX Security Terminals MT/U 2.12.2, MT/S 4.12.2M and 8.12.2M Product Manual
ABB i-bus KNX Security Terminals MT/U 2.12.2, MT/S 4.12.2M and 8.12.2M Product Manual Contents Contents Page 1 General 3 1.1 Use of the product manual...3 1.1.1 Structure of the product manual...3 1.1.2
D-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51
34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
7 Lighting Technology
7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light
5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................