Applications. diris_826_a_1_gb_cat
|
|
|
- Godwin Berry
- 10 years ago
- Views:
Transcription
1 Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered by the DIRIS A40, and which also allow the user to detect events that may harm the installation, linking these to a graphic representation. All this information can be used and analysed remotely using quality measurement software. Conformity to standards IEC IEC class 0,5 S IEC class 2 Applications diris_826_a_1_gb_cat In addition to the functions of the DIRIS A40, the also: shows the current and voltage unbalance shows the tangent phi stores the load curves (50 days with an interval of 10 minutes) for: Active, reactive and apparent power: ΣP+/- ; ΣQ+/-, ΣS. detects and stores the last 40 events concerning: - overvoltage - voltage dips - outages - overcurrent For each stored event, the DIRIS A60 records the relevant RMS 1/2 interval curves for the voltages V1, V2, V3, U12, U23, U31 and the currents,,, In, giving a total of 400 curves. Other functions : DIRIS A40 DIRIS A40 DIRIS A40 Multimeasurement Current - instantaneous:,,, In, Isystem, - maximum:,,, In - unbalance: I unb Voltages & frequency - instantaneous: U1, U2, U3, U12, U23, U31, F, Vsystem, Usystem - maximum: U1, U2, U3, U12, U23, U31, F - unbalance: U unb Powers - instantaneous: 3P, ΣP, 3Q, ΣQ, 3S, ΣS - moyen maximum: ΣP, ΣQ, ΣS - predictive: ΣP, ΣQ, ΣS Power factor - instantaneous: 3PF, ΣPF Total tangent phi - maximum: ΣPF PC CONTROL VISION software PLC Ethernet Main meter panel Temperatures (1) - Internal - external via 3 PT100 sensors Metering Active energy: +/- kwh Reactive energy: +/- kvarh Apparent energy: kvah Hours: Harmonic analysis (level 63) Total harmonic distortion - Currents: thd, thd, thd, thd In - Phase-to-neutral voltage: thd U1, thd U2, thd U3 - Phase to phase voltage: thd U12, thd U23, thd U31 Individual - Currents: H, H, H, HIn - Phase-to-neutral voltage: HU1, HU2, HU3, - Phase to phase voltage: HU12, HU23, HU31 Events (1) Alarms on all electrical values Communications (1) Analogue 0/4-20 ma Digital (Jbus/Modbus & Profibus-DP) Ethernet (modbus/tcp or Jbus/ Modbus RTU over TCP and Web server) Ethernet with gateway Jbus/Modbus RTU over TCP Currents per phase curve Inputs / Outputs (1) Pulse metering Control/command of devices Alarm report Pulse report (1) Available as an option (see the following pages). appli_386_a General Catalogue SOCOMEC
2 Measurement units Front panel diris_824x_a_1_cat Plug-in modules DIRIS A60 diris_773_a Backlit LCD screen. 2. Pushbutton for currents, temperatures and CT setup wiring correction. 3. Pushbutton for voltages and frequency. 4. Pushbutton for active, reactive, and apparent power and power factor. 5. Pushbutton for maximum and average current and power values. 6. Pushbutton for harmonics. 7. Pushbutton for energies and hour run meter. diris_445_a_1_cat diris_447_a_1_cat diris_775_a_1_cat diris_777_a_1_cat diris_776_a_1_cat diris_448_a_1_cat Pulse outputs 2 configurable pulse outputs (type, weight and run) on ±kwh, ±kvarh and kvah. JBUS / MODBUS communication link with JBUS / MODBUS protocol (speed up to bauds). PROFIBUS DP communication link with PROFIBUS DP protocol (speed up to 12 Mbauds). Ethernet communication Ethernet link with MODBUS/TCP or JBUS/MODBUS RTU over TCP. Ethernet communication with Gateway JBUS/MODBUS Ethernet link with MODBUS/TCP or JBUS/MODBUS RTU over TCP. Connection of 1 to 247 JBUS/MODBUS slaves. Analogue outputs A maximum of 2 modules may be connected, giving 4 analogue outputs. 2 outputs assignable to: 3I, In, 3V, 3U, F, ± ΣP, ± ΣQ, ΣS, ΣPFL/C, I sys, Vsys, Usys, Ppred, Q pred, Spred, internal T C, T C 1, T C 2, T C3 and to 17 VDC power supply. 2 inputs - 2 outputs diris_449_a_1_cat A maximum of 3 modules may be connected, giving 6 inputs. 2 outputs assignable to : - monitoring: 3I, In, 3V, 3U, F, ± ΣP, ± ΣQ, ΣS, ΣPFL/C, THD 3I, THD In, THD 3V, THD 3U, Ppred, Qpred, Spred, internal T C, T C 1, T C2, T C3 and hour meter, - remotely controlled, - timed remote control, - 2 inputs for pulses metering. SOCOMEC General Catalogue
3 - Accessories Current transformer (see page XXX) Current transformers IP65 protection Device embedded with kit for 144 x 96 mm cutout trafo_024_a_2_cat diris_569_a_1_x_cat diris_571_a_1_x_cat Terminals V1 DIRIS A40 V2 0 V - + V3 Communication module 1 0n VN R = 120 trafo_077_b_2_cat A U X link. R = 120 Ω: internal resistance for link. diris_572_a_1_x_cat Pulse output module OUT 1 OUT 2 1-2: pulse output n : pulse output n 2. diris_573_a_1_x_cat Analogue output module /4-20 ma 0/4-20 ma OUT 1 OUT 2 5-6: Analogue output n : Analogue output n 2. diris_574_b_1_x_cat diris_720_a_2_cat 2 inputs / 2 outputs module OUT 1 A-Cd IN 1 OUT 2 A-Cd IN : relay output n : relay output n : opto input n : opto input n 2. diris_753_a_1_fr_cat Temperature module DIRIS A40/A41 sonde onde 2 sonde 3 diris_718_b_1_cat - : Current inputs AUX: auxiliary power supplies Us V1 - V2 - V3 - VN: voltage inputs Ethernet module + gateway JBUS/MODBUS diris_751_a_1_fr_cat diris_752_a_1_x_cat 10 BASE T 100 BASE T RJ45 DIRIS A40/A41 Ethernet Module 10 BASE T 100 BASE T RJ45 DIRIS A40/A41 0 V - + Interface General Catalogue SOCOMEC
4 Measurement units Characteristics Current measurement on insulated inputs (TRMS) CT primary A CT secondary 1 or 5 Measurement range 0 11 ka Input consumption 0.1 VA Accuracy 0.2 % Sustained overload 6 A Intermittent overload 10 In for Voltage measurements (TRMS) Direct measurement between phases VAC Direct measurement between phase VAC and neutral VT primary VAC VT secondary 60, 100, 110, 173, 190 VAC Frequency 50 / 60 Hz Input consumption 0.1 VA Accuracy 0.2 % Sustained overload 760 VAC Current-voltage product Limitation for 1A CT Limitation for 5A CT Power measurement Accuracy 0.5 % Power factor measurement Accuracy 0.5 % Frequency measurement Measurement range Hz Accuracy 0.1 % Energy accuracy Active (according to IEC ) class 0.5 S Reactive (according to IEC ) class 2 Auxiliary supply AC voltage VAC AC tolerance ± 10 % DC voltage VDC DC tolerance ± 20 % Frequency 50 / 60 Hz Consumption 10 VA Case Outputs (alarms / control) Number of relays VAC - 5 A VA Phototransistor inputs Number 2 6 Power supply VDC Minimum signal width 10 ms Minimum length between 2 impulses 18 ms phototransistor Outputs (pulses) Number of relays VDC A - 10 VA Max. number of operations 10 8 Outputs (analogue) Number of outputs 2 4 insulated Range 0 / 4 20 ma Charging resistance 600 Ω Maximum current 30 ma Communication Link Protocol JBUS/MODBUS speed Protocol PROFIBUS speed Ethernet communication Link Speed Protocol 2 3 half duplex wires JBUS/MODBUS in RTU mode bauds PROFIBUS DP 9,8 kbauds 12 Mbauds Temperature inputs PT100 Link 2 or 4 wires Range - 20 C C Accuracy +/- 1 digit Maximum length 300 cm RJ45 10 base T / 100 base T MODBUS TCP or JBUS/MODBUS RTU over TCP Operating conditions Operating temperature C C Storage temperature C C Relative humidity 95 % panel mounting Dimensions W x H x D 96 x 96 x 60 mm Case protection rating IP30 Front protection rating IP52 Display type LCD Terminal blocks type fixed or pull-out Voltage and other connection section 0.2 2,5 mm 2 Current connection section mm 2 Weight 400 g 96 DIRIS A diris_582_c_1_x_cat SOCOMEC General Catalogue
5 - Connection Recommendation: While disconnecting the DIRIS, the secondaries of each current transformer must be short-circuited. This operation can be carried out automatically from a product in the SOCOMEC catalogue, PTI: Please consult us. Low voltage balanced network for 3/4 wires with 1 CT Single phase Two phase diris_392_d_1_gb_cat N Use of 1 CT reduces by 0.5% the accuracy of the phases whose current is worked out by vector calculation. diris_395_d_1_gb_cat diris_398_c_1_x_cat Low voltage unbalanced network for DIRIS A40 3/4 wires with 3 CTs Additional information Communication via link 0 V - + LIYCY-CY ON diris_393_d_1_gb_cat N diris_396_d_1_gb_cat diris_399_b_1_x_cat 1 1 = Fus. 0.5 A gg / BS88 2 A gg / 0.5 A CC Class N diris_394_d_1_gb_cat wires with 2 CTs 3 wires with 2 CTs Use of 2 CTs reduces by 0.5% the accuracy of the phase whose current is worked out by vector calculation. Connection of voltage transformer for HV networks V1 V2 V3 N diris_397_d_1_gb_cat Use of 2 CTs reduces by 0.5% the accuracy of the phase whose current is worked out by vector calculation. diris_400_g_1_gb_cat Connection of voltage transformer for HV networks 110 / 400 VAC (IEC) 120 / 350 VDC (IEC) A U X It is recommended that the auxiliary power supply be protected by the use of 500 ma gg fuses. General Catalogue SOCOMEC
6 Measurement units References diris_824_a_1_cat Standard device Auxiliary power supply Us Accessories Reference Description Reference IP65 protection Panel mounting kit for a 144 x 96 mm cutout Optional features Plug-in modules (1) Reference Pulse outputs JBUS / MODBUS communication Analogue outputs inputs / 2 outputs PROFIBUS DP communication Ethernet communication Ethernet communication + gateway JBUS/MODBUS Temperature inputs (1) Ease of integration for additional functions (maximum 4) by clutchable modules on the rear side of the device, by the user at any moment. SOCOMEC General Catalogue
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
Metering devices. Features The high-quality measuring technology of the device facilitates 4-quadrant power metering. In this way, metering
Metering devices Current grid values of your power distribution system at a glance at all times. Multifunctional metering devices by EFEN have an important share in improving energy efficiency and system
User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Eaton s E-Series protective relay family
E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
DIRIS A40/A41 RS485 JBUS/MODBUS. Operating instructions F GB D I NL E P
DIRIS A40/A41 RS485 JBUS/MODBUS Operating instructions F GB D I NL E P COM DIRIS A40/A41 - Ref.: 536 103 A GB GB Contents PRELIMINARY OPERATIONS 4 GENERAL INFORMATION 4 INSTALLATION 5 CONNECTION 5 PROGRAMMING
Power monitoring unit type VAMP 260
Power monitoring unit type VAMP 260 formerly known as VMAC 260 Slide 1 / 18 The complete source of information Slide 2 / 18 The complete source of information Users - utilities -industry - power plants
EARTH LEAKAGE PROTECTION: CONTENTS
EARTH LEAKAGE PROTECTION: CONTENTS Earth Leakage Relays 128-130 Trip Circuit Supervision Relays 128-130 TEMPROTECT Protection and Distribution 1A to 6300A page 127 EARTH LEAKAGE PROTECTION ELR-1E The ELR-1E
Managing. Energy management and power analysis
management and power analysis Power monitors IN 96 and 144 - Selection table... 68 - IN 96, recdigit NOUS... 70 - IN 144, recdigit POWER... 72 - Multi-display recisplay... 73 Winthor software... 74 Managing
Electrical measurement and control M.5. CVM Power analyzers
Electrical measurement and control M.5 CVM Power analyzers M.5 CVM Power analyzers M.5 - CVM Power analyzers CVMk2 Three-phase power analyzer(balanced and unbalanced) for panel or DIN rail mounting M5-8
Model 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter
Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances
Power Meter Series 800
PowerLogic power-monitoring units Power Meter Series 800 Technical data sheet 2007 Functions and characteristics E90463 PB101813-51 PB101823-50 DB111799 Front view of Power Meter Series 800 meter with
TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES
SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
Energy Management Power Analyzer Type WM14-96 Basic Version
Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer
Electrical Measuring Instruments
Electrical Measuring Instruments Index Contents: Page Measuring Centres MC 320 Energy meter, MC 330 Multimeter 3 MC 760/UMC 760 Network Analyzer, MC 750/UMC 750 - Network Recorder 5 MC 740 Multifunction
Energy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation
DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)
100% electricity Digital multimeters and power analyzers series DIGITAL MULTIMETERS AND POWER ANALYZERS with backlit graphic LCD screen For the control of energy distribution systems detecting when problems
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
Counter for Energy. We make energy measurable and secure your future. www.g-mw.de
Counter for Energy We make energy measurable and secure your future www.g-mw.de 10 reasons for GMW Customer oriented solutions Individual consultancy Satisfied customers in all continents Large range of
M2M The measure of efficiency
M2M The measure of efficiency The importance of control Measurement and advanced analysis of electrical parameters To make equipment as efficient as possible, it is essential to know the details of its
T 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
One Meter Works for Both Energy Saving and Power Quality Surveillance
Multi-Function Meter Eco-POWER METER W9M SERIES Conforming to ow Voltage and EMC Directives One Meter Works for Both Energy Saving and Quality Surveillance High accuracy: 0.2 %* Harmonic measurement* Simple
Measurement and electric control. CVM Power analyzers
Measurement and electric control CVM Power analyzers CVM Power analyzers Nowadays, companies, industries or any consumer of electrical energy are trying to optimise costs to become the most competitive
Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144
Automatic Transfer Switch-Controller ATS-C by Eaton Automatic Transfer Switch- Controller ATS-C 96 and C 144 Supply safety for low voltage energy distribution. Automatic Transfer Switch-Controller ATS-C
Measuring and monitoring units VAMP 96 VAMP 260 WIMO 6CP10
Measuring and monitoring units VAMP 96 Measuring and monitoring units Main characteristics Intelligent measuring and monitoring units The VAMP and WIMO meters come with an extensive selection of pre-configured
Metering Devices IQ Analyzer 6400/6600 Series
Metering Devices IQ Analyzer 6400/6600 Series Technical Data Supersedes TD.17.02A.T.E pages 1-8 dated May 2000 Description Page General Description............................................. 2 Applications....................................................
PLA 44. Power quality analyzer. User and service manual. BMR trading
PLA 44 Power quality analyzer User and service manual version 1.2 BMR Lipovka 17 516 01 Rychnov n. Kn. 1 Tel: +420 774 415 703 Fax: +420 494 533 602 Content 1. Front panel...3 5.6.1. List of events...8
Static energy meters
Static energy meters 2.01 Model Conto D1 Conto D2-b Codes CE11165A0 CE11165A2 CE21175A0 Ordering codes see page: 09 09 09 Connection on line single-phase single-phase Active energy class 1 EN62053-21 class
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks
SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks Introduction SCADA (Supervisory Controlled and Data Acquisition) controlled multi-step metalenclosed automatic capacitor
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Process Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical
Technical note NT588 NT604 NT695 NT782
Multifunction 1.01 Model Nemo D4-b Nemo D4-L Nemo D4-L+ Codes MF6GT MF6FT0 MF6FTU MF6FT4 MF6HTU... MF6HT4... MF6HB... Ordering codes see page: 08 08 08 08 08 08 08 Connection on line single phase, 3-phase
3-phase, bidirectional energy meter
Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured
1. INTRODUCTION FEATURES 2. PROGRAMMING
1. INTRODUCTION Mono phase compensation systems are not useful in plants where unbalanced loads exist. In such plants compensation has to be done by measuring all 3 phase parameters individually. Devices,
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Maximum Demand Control
Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.
56 / Accessories for inverters Accessories for inverters / Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. FRONIUS STRING
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
M1000 Process Alarm Monitor
Data Sheet Process Alarm Monitor Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
Technical Information POWER PLANT CONTROLLER
Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for
PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet
PowerLogic power-monitoring units PM5350 power meter Technical data sheet Mid-range metering PM5350 Functions and characteristics PE86278 The PowerLogic PM5350 power meter offers all the measurement capailities
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
Operating instructions. AS-i Profibus gateway AC1411 / AC1412 7390884/00 04/2014
Operating instructions AS-i Profibus gateway AC1411 / AC1412 7390884/00 04/2014 Contents 1 Preliminary note 4 1.1 Notes on this document 4 1.2 Symbols used 4 2 Safety instructions 4 2.1 General 4 2.2 Installation
Panorama Electricity meters For reliable values of energy consumption
Panorama Electricity meters For reliable values of energy consumption Why measure Electrical Energy Energy cost is on the rise. It is therefore in the interest of both private and commercial customers
AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?
How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment? PowerLogic PM800 series power meters Buildings Industry Data Center Compact power, energy and power quality meters The Square D PowerLogic
Measurement and Control CVM. Power analyzers. Energy efficiency technology
Measurement and Control CVM Power analyzers Energy efficiency technology More than simply measuring... Manage Record the real cost of your manufacturing processes and the kgco 2 emissions of your installation
THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012
Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal
Ponto Series. A new concept for automation
Ponto Series A new concept for automation Programmable Controller Remote I/O for Field Buses Special models of I/O modules Web connection Ponto Series Programmable Controller High connectivity CPUs Direct
Communicate and view data from meters with one simple device
Communicate and view data from meters with one simple device PowerLogic EGX300 integrated gateway-server Web Monitoring Communications Plug and Play Plug into your energy usage with a simple mouse click
Digital multimeters DMG 600-610
Digital multimeters DMG 600-610 Digital multimeters DMG 600-610 are capable of viewing the measurements with high accuracy on the wide LCD display, which allow to control energy distribution networks.
Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G 3891 0020
Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G 3891 0020 Built-in Dupline channel generator PROFIBUS-DP slave according to EN 50 170 Certified by the PNO PROFIBUS-DP communication
BB800 Off-Grid Solar System
BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry
Auto-tune PID. Temperature Controller BRAINCHILD FEATURES
Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS
via PROFINET or AS-i 3.0 Gateways, via PROFINET or 2 / 1 Master, PROFINET / Slave AS-i Safety input slaves report via AS-i Safety output slaves switch via 1 Safety Monitor for 2 AS-i networks Operation
EM-PQ 1500 Power Quality Monitor. Operating Manual
EM-PQ 1500 Power Quality Monitor Operating Manual 1 User notes: 2 Contents Page Page 1. Quick start... 5 2. Description... 6 2.1 Operating principle... 6 3. Installation... 8 3.1 Mounting... 8 3.2 Electrical
Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0
The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection,
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
Power quality monitoring and analysis with reliability
Power quality monitoring and analysis with reliability PowerLogic CM4000 series circuit monitors Buildings Industry Data Center Intelligent metering and control devices Whether in offices, classrooms,
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Polyphase kwh Electricity Meter
Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2
4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE
Perfect Welding Solar Energy Perfect Charging FRONIUS ENERGY PACKAGE The personal storage solution for 24H Sun. PC board replacement process SnapINverter technology Integrated data communication Dynamic
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management
Energy Depot GmbH Delivering Solutions for Energy Management PRODUCT AND APPLICATION GUIDE Total Monitoring Solution for PV SOLAR LOGGER & ANALYSIS DC STRING MONITORING Residential Comprehensive Solar
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
SOLAR300N Rel. 1.03 21/01/10
Photovoltaic installation certifier + professional network analyzer Pag 1 of 5 1. SOLAR300N MAIN FEATURES SOLAR300N performs all tests on PV plants by using of SOLAR-02 remote unit which, after a preliminary
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
VIBROCONTROL 4000. Sensitive Machine Monitoring
VIBROCONTROL 4000 Sensitive Machine Monitoring Reliable Machine Protection with VIBROCONTROL 4000 Brüel & Kjaer Vibro has for many years been one of the leading manufacturers of machine protection systems.
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C
Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
Current and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8
CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description
SHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous
High Power Programmable DC Power Supplies PVS Series
Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient
Communication and connectivity the ideal solution for integrated system management and data integrity
the ideal solution for integrated system management and data integrity The solution for Management solutions > Data centre > Emergency applications > Offices > Service industries > Industry > Telecommunications