A project to optimise quality and energy efficiency must include metering

Size: px
Start display at page:

Download "A project to optimise quality and energy efficiency must include metering"

Transcription

1 EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken, and downstream to monitor the effects and control any drift. Legrand EMDX³ metering range will naturally have a place in distribution boards. EMDX 3 metering control units All the essential parameters of the installation on DIN rail or on the door : - Active and reactive energy - Operating time - Power factor - Harmonic distortion - Programmable alarms 80 EMDX³ unit on DIN rail EMDX³ unit on door EMDX³ units on doors provide a large size display and their capacity can be increased with extension modules.

2 Eco-design a voluntary approach The Legrand group has been taking environmental problems into account since 00. This approach is based on international standards for the objective measurement of the environmental impacts of products in terms of both consumption of resources and pollution. Legrand publishes these reports in the form of PEP (Product Environmental Profile) sheets. Remote supervision and viewing With the Legrand communication interfaces (RS 485, IP), supervision software and Web servers, measurements can be centralised and displayed remotely on a PC, tablet or smartphone. EMDX 3 electricity meter on DIN rail EMDX³ meters installed in secondary distribution boards can be used to monitor consumption per building, per floor and per application. Display of 3 measurement points on tablet computers and WEB SERVERS Electrical energy meters, p. 8 8

3 EMDX 3 electrical energy meters 4 rail mounting NEW EMDX 3 multi-function metering units 4 rail mounting Technical characteristics p Technical characteristics p Measure the electricity consumed by a single-phase or three-phase circuit downstream of the electricity distribution metering Display electricity consumption in kwh, as well as other values such as current, active energy, reactive energy and power (depending on the catalogue number) Conform to standards IEC 6053-/3, IEC 605- and IEC 600- MID compliance ensures accuracy of the metering with a view to recharging for the electricity used Pack Cat.No. Single-phase meters Non-MID MID Direct connection compliant A - module A - modules A - modules A - modules RS 485 output Three-phase meters Non-MID MID Direct connection compliant A - 4 modules A - 4 modules RS 485 output Connection with CT A - 4 modules pulse output A - 4 modules RS 485 and pulse output Conform to standards: - IEC IEC class 0.5 S - IEC class Pack Cat.No. EMDX 3 modular For mounting on rail Width: 4 modules LCD display Measurement of currents, voltages, active, reactive and apparent power and internal temperature Dual tariff metering: - Active energy consumed - Reactive energy consumed - Operating time - Power factor THD voltages and currents up to order 5 Programmable alarms on all functions Outputs for controlling wiring devices, alarm feedback and pulse feedback EMDX 3 pulse unit Data transmission via pulses EMDX 3 RS 485 unit Data transmission via RS 485 communication interface and pulses Concentrator For collecting and transmitting measurements taken by 7 universal pulse electricity meters Also collects data from other meters (gas meters, water meters, etc.) RS485 output 4 modules 8

4 EMDX 3 multi-function metering units for mounting on door or solid faceplate NEW Current transformers (CT) p. 84 Technical characteristics p Conform to standards: - IEC IEC class 0.5 S - IEC class Pack Cat.No. EMDX 3 - Access Multi-function metering unit For mounting on door or solid faceplate Dimensions: 96 x 96 x 60 mm LCD display Measurement of currents, voltages, active, reactive and apparent power, internal temperature and power factor Metering: - Active energy consumed or produced - Reactive energy consumed or produced - Operating time - Pulses THD voltages and currents up to order 5 Programmable alarms on all functions Can take optional modules Modules for EMDX 3 - Access multi-function metering unit RS485 communication module MODBUS link output module Can be assigned to pulse feedback, alarm feedback or control of wiring devices EMDX 3 - Premium Multi-function metering units For mounting on door or solid faceplate Dimensions: 96 x 96 x 60 mm LCD display Measurement of currents, voltages, active, reactive and apparent power, internal temperature and power factor Metering: - Active energy consumed or produced - Reactive energy consumed or produced - Operating time - Pulses Individual harmonics up to order 63 Programmable alarms on all functions Can take 4 optional modules Modules for EMDX 3 - Premium multi-function metering units RS 485 communication module MODBUS link Storage module Storage of active and reactive power over 6 days, the last 0 alarms and the average voltage and frequency values over 60 days max Module with inputs/ outputs Up to 3 modules, i.e. 6 inputs/6 outputs, can be installed Outputs can be assigned to monitoring mode, remote control or timed remote control Temperature module Indication of the internal temperature and possibility of connecting 3 sensors for measuring the external temperature Pack Cat.No. Communication and supervision Web servers Enable remote viewing, via a web browser on PCs, smartphones, web viewers, tablet computers such as ipads, Archos, etc., of values collected on electricity meters and multi-function metering units For 3 metering points (meters or multi-function metering units) For an unlimited number of metering points (meters or multi-function metering units) Legrand software dedicated to measurement For displaying the values collected from electricity meters or multi-function metering units on a PC connected to the network For 3 metering points (supplied on CD) For an unlimited number of metering points (supplied on CD) Legrand supervision software - made-to-measure For customised display of the values collected and control of the power installation on a PC IP converter For RS 485 / Ethernet conversion for connecting electricity meters and multi-function metering units to an IP network. Please consult Legrand for more information 83

5 current transformers CT current transformers CT n Current transformers (CT) Technical characteristics Degree of protection: IP 0 Operating frequency : 50/60 Hz Dimensions Single-phase CTs Cat. No /34/36 for 6 x.5 mm bar and Ø mm cable Fixing on EN 6075 rail Pack Cat.No. Single-phase current transformers (CT) Used with ammeters, electricity meters or multi-function measuring units Provide a 0 to 5 A current at the secondary, proportional to the primary current For fixing on plates, EN rail Cat.No /34/36, or bars Secondary connected by terminals or lugs Precision class % For 6 x.5 mm bar and Ø mm cable Transformation ratio Output (VA) / / /5 5.5 For 40.5 x 0.5 mm bar and Ø35 mm cable /5 For 65 x 3 mm bar / / /5 0 For 7 x 38 mm bar / /5 0 For 7 x 54 mm bar / / ,5 Cat. No for 40.5 x 0.5 mm bar and Ø35 mm cable Fixing on EN 6075 rail or on plate D A B C 45 Cat. No. A B C D Ø Fixing centres on plate x 45 Cat. No /77/78 for 65 x 3 mm bar Fixing on bar D A B C Cat. No. A B C D /77/ Cat. No /46 for 7 x 38 mm bar Cat. No and for 7 x 54 mm bar Fixing on bar B A Cat. No. A B / / Determination of the max. distance between CT and meter Cat. No. Max. power of CT Meter consump. (W) Max. loss in capac. (VA) Max. distance bet. CT & meter (m) Wiring.5 mm Wiring 4 mm Wiring 6 mm /

6 EMDX 3 electrical energy meters 4 rail mounting n Technical characteristics Single-phase meters Cat. Nos /7/77/78/79/8 LCD display: 7 digits Resolution: 0. kwh Maximum indication: kwh Metrological LED: Wh/pulse (Cat.No : 0.5 Wh/pulse) Accuracy (EN 6053-): class Reference voltage Un: 30 V-40 V Reference frequency: Hz : pulse/0 Wh (Cat.No : pulse/wh) Three-phase meters Cat. Nos /74/80/8/83/84/85/86 LCD display: 8 digits Resolution: 0.0 kwh () Maximum indication: kwh () Metrological LED: 0. Wh/pulse or Wh/pulse Active energy accuracy (EN 6053-): class Reactive energy accuracy (EN ): class Reference voltage Un: - Single-phase: V - Three-phase: 30(400)-40(45) V Operating limit range (EN 6053-, EN ): - Single-phase: 0 to 54 V - Three-phase: 0(90) to 54(440) V : pulse/0 Wh Cat. No Number of modules Connection Direct Via a current transformer Single-phase Three-phase Max. current 3 A 36 A 63 A 63 A 63 A 63 A 63 A 63 A 63 A 63 A 5 A (CT) Metering Communication MID compliant Operating conditions Total active energy Total reactive energy Partial active energy (reset) Partial reactive energy (reset) Active power Reactive power Apparent power Current Voltage Frequency Power factor Time-of-use Average active power Max. average active power value Dual tariff RS 485 interface Reference temperature 3 C ± C Operating temperature -0 to +55 C -0 to +45 C -5 to +55 C Storage temperature -40 to +70 C -5 to +70 C -5 to +70 C Consumption 8 VA 4 VA per phase VA per phase Heat dissipation 6.5 W 6 W 4 W 5 A (CT) 5 A (CT) 5 A (CT) n Interfacing with IP communication network Pulse electricity meters RS 485 electricity meters Concentrator Cat. No Connects up to 7 pulse electricity meters RS Fieldbus RS 485/IP converter Cat. No IP network - Communication bus : For direct connection meters If connected via transformers, the resolution and maximum indication depend on the transformation ratios of these transformers 85

7 EMDX 3 multi-function metering units n Technical characteristics Cat.No / Connection Protection index Current measurement terminals 4 mm 6 mm 6 mm Other terminals.5 mm.5 mm.5 mm Front cover IP 5 IP 5 IP 5 Casing IP 0 IP 30 IP 30 Weight 05/5 g 400 g 400 g Display Backlit LCD Backlit LCD Backlit LCD Measurements 3P+N, 3P, P, P+N 3P+N, 3P, P, P+N 3P+N, 3P, P, P+N Direct Phase/phase 50 to 50 VA 50 to 500 VA 8 to 700 VA Phase/neutral 8 to 300 VA 8 to 89 VA to 404 VA Voltage measurement From a PT Primary kv Secondary , 00, 0, 5, 0, 73, 90 VA Permanent overload between phases 760 VA 800 VA 760 VA Update period s s s From a CT Primary 5 to 9999 A 9999 A 9995 A Secondary 5 A 5 A or 5 A Minimum measurement 5 ma 5 ma 0 ma Input consumption < 0.6 VA < 0.6 VA < 0.3 VA Current measurement Display 0 to 9999 A to ka 0 to ka Permanent overload 6 A 6 A 0 A Intermittent overload 60 A/ s - 0 A/0.5 s 0 In/ s 0 In/ s Update period s s s Max. CT x PT ratio Power measurement Total 0 to 9999 kw/kvar/kva 0 to MW/Mvar/MVA 0 to 8000 MW/Mvar/MVA Update period s s s Frequency measurement Measurement range 45.0 to 65.0 Hz 45.0 to 65.0 Hz 45.0 to 65.0 Hz Update period s s s 50/60 Hz 00 to 77 VA ±5% 0 to 400 VA ±0% 0 to 400 VA ±0% Auxiliary power supply DC - 0 to 350 V= ±0% 0 to 350 V= ±0% Consumption < 5 VA < 0 VA < 0 VA Operating temperature -0 C to +55 C -0 C to +55 C -0 C to +55 C Storage temperature -0 C to +70 C -0 C to +85 C -0 C to +85 C n Flush-mounting dimensions Cat.No /69 n Fixing on door Cat.No / ,8-0, ,8-0, n Fitting modules Cat.No /69 86

8 n Connection solutions Unbalanced three-phase network (3 or 4-wire) (3-wire) I I I3 S S S V V V3 VN AUX I I I3 S S S V V V3 VN AUX I I I3 S S S V V V3 VN AUX L (R) L (S) L3 (T) N L (R) L (S) L3 (T) L (R) L (S) L3 (T) Balanced three-phase network (3 or 4-wire) I I I3 S S S V V V3 VN AUX Single-phase network (-wire) I I I3 S S S V V V3 VN AUX Two-phase network (-wire) I I I3 S S S V V V3 VN AUX L (R) L (S) L (R) N L (R) L (S) L3 (T) N a Auxiliary power supply: VAC/0 350 VDC b Fuse: 0.5 A gg/bs 88 A gg/0.5 A class CC n Interfacing with IP communication network Ethernet TCP/IP network Web server Cat.Nos /79 or PC with supervision software Cat.Nos /89 RS485/Ethernet converter Cat.No Multi-function measuring unit Cat.No RS485/Ethernet converter Cat.No RS485 fieldbus Multi-function measuring unit Cat.No with RS485 communication module Cat.No RS485 fieldbus RS485 modular multi-function measuring unit Cat.No RS485 modular multi-function measuring unit Cat.No RS485 modular multi-function measuring unit Cat.No Main LV distribution board Secondary board 87

Applications. diris_826_a_1_gb_cat

Applications. diris_826_a_1_gb_cat Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)

How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time) 100% electricity Digital multimeters and power analyzers series DIGITAL MULTIMETERS AND POWER ANALYZERS with backlit graphic LCD screen For the control of energy distribution systems detecting when problems

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

Static energy meters

Static energy meters Static energy meters 2.01 Model Conto D1 Conto D2-b Codes CE11165A0 CE11165A2 CE21175A0 Ordering codes see page: 09 09 09 Connection on line single-phase single-phase Active energy class 1 EN62053-21 class

More information

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

EARTH LEAKAGE PROTECTION: CONTENTS

EARTH LEAKAGE PROTECTION: CONTENTS EARTH LEAKAGE PROTECTION: CONTENTS Earth Leakage Relays 128-130 Trip Circuit Supervision Relays 128-130 TEMPROTECT Protection and Distribution 1A to 6300A page 127 EARTH LEAKAGE PROTECTION ELR-1E The ELR-1E

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

3-phase, bidirectional energy meter

3-phase, bidirectional energy meter Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured

More information

Maximum Demand Control

Maximum Demand Control Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

Energy Management Power Analyzer Type WM14-96 Basic Version

Energy Management Power Analyzer Type WM14-96 Basic Version Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer

More information

Metering devices. Features The high-quality measuring technology of the device facilitates 4-quadrant power metering. In this way, metering

Metering devices. Features The high-quality measuring technology of the device facilitates 4-quadrant power metering. In this way, metering Metering devices Current grid values of your power distribution system at a glance at all times. Multifunctional metering devices by EFEN have an important share in improving energy efficiency and system

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

M2M The measure of efficiency

M2M The measure of efficiency M2M The measure of efficiency The importance of control Measurement and advanced analysis of electrical parameters To make equipment as efficient as possible, it is essential to know the details of its

More information

Technical note NT588 NT604 NT695 NT782

Technical note NT588 NT604 NT695 NT782 Multifunction 1.01 Model Nemo D4-b Nemo D4-L Nemo D4-L+ Codes MF6GT MF6FT0 MF6FTU MF6FT4 MF6HTU... MF6HT4... MF6HB... Ordering codes see page: 08 08 08 08 08 08 08 Connection on line single phase, 3-phase

More information

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7 Energy Meters INDEX 1 Measurement Digital single-phase Energy-meters Direct till 32 A 1 module DIN page 5 Digital single-phase Energy-meters Direct till 45 A 1 module DIN page 6 Digital single-phase Energy-meters

More information

Counter for Energy. We make energy measurable and secure your future. www.g-mw.de

Counter for Energy. We make energy measurable and secure your future. www.g-mw.de Counter for Energy We make energy measurable and secure your future www.g-mw.de 10 reasons for GMW Customer oriented solutions Individual consultancy Satisfied customers in all continents Large range of

More information

Energy meters For an efficient control of energy consumption

Energy meters For an efficient control of energy consumption Energy meters Energy meters For an efficient control of energy consumption In a modern world in which energy must be monitored and controlled in the most efficient way possible, LOVATO Electric presents

More information

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw PV energy, combined with energy storage systems, can help increase self-consumption and energy selfsufficiency*. One of the biggest challenges

More information

3-Phase Energy meter with serial S-Bus interface

3-Phase Energy meter with serial S-Bus interface Data sheet www.sbc-support.com 3-Phase Energy meter with serial S-Bus interface Energy meters with an integrated S-Bus interface allow direct reading of all relevant data, such as energy (Total and partial),

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Process Alarm Solutions

Process Alarm Solutions Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

Current transformers (CT) & Shunts

Current transformers (CT) & Shunts Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144

Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144 Automatic Transfer Switch-Controller ATS-C by Eaton Automatic Transfer Switch- Controller ATS-C 96 and C 144 Supply safety for low voltage energy distribution. Automatic Transfer Switch-Controller ATS-C

More information

Measurement and Control CVM. Power analyzers. Energy efficiency technology

Measurement and Control CVM. Power analyzers. Energy efficiency technology Measurement and Control CVM Power analyzers Energy efficiency technology More than simply measuring... Manage Record the real cost of your manufacturing processes and the kgco 2 emissions of your installation

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053. PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Smile. The All-In-One Heating Controller

Smile. The All-In-One Heating Controller Smile EVERYTHING UNDER CONTROL The All-In-One Heating Controller Versatile, energy-efficient heating control. The All-In-One Heating Controller Smile controllers are ideal to gain maximum efficiency from

More information

Electrical measurement and control M.5. CVM Power analyzers

Electrical measurement and control M.5. CVM Power analyzers Electrical measurement and control M.5 CVM Power analyzers M.5 CVM Power analyzers M.5 - CVM Power analyzers CVMk2 Three-phase power analyzer(balanced and unbalanced) for panel or DIN rail mounting M5-8

More information

Current and Energy. Measurement Technology

Current and Energy. Measurement Technology Current and Energy Measurement Technology Current Measurement and Evaluation WAGO s Solution for Energy Monitoring and Conservation Rogowski Coils, 855 Series Conversion of AC currents up to 500 A/2000

More information

Digital Ground Resistance Tester. Models 4620 & 4630. Digital Ground Resistance Tester

Digital Ground Resistance Tester. Models 4620 & 4630. Digital Ground Resistance Tester Digital Ground Resistance Tester Models 4620 & 4630 Digital Ground Resistance Tester Models 4620 and 4630 perform both ground resistance and soil resistivity tests. These testers measure from 0 to 2000Ω,

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series Communication system for the management of electrical installations INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series MID Approval Technology for energy efficiency PLC Communications (Power Line Communication)

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

TX2123 RS485 TO ETHERNET ADAPTOR

TX2123 RS485 TO ETHERNET ADAPTOR TX2123 RS485 TO ETHERNET ADAPTOR Converts Datacomms between fibre optic Modbus TCP over Ethernet and hard-wired copper Modbus RTU over RS485 Fibre Optic MODBUS TCP/ IP Ethernet Copper MODBUS RTU RS485

More information

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. 56 / Accessories for inverters Accessories for inverters / Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. FRONIUS STRING

More information

EM-PQ 1500 Power Quality Monitor. Operating Manual

EM-PQ 1500 Power Quality Monitor. Operating Manual EM-PQ 1500 Power Quality Monitor Operating Manual 1 User notes: 2 Contents Page Page 1. Quick start... 5 2. Description... 6 2.1 Operating principle... 6 3. Installation... 8 3.1 Mounting... 8 3.2 Electrical

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation Galleon 6-10K Online UPS Voltronic Power Technology Corporation Features Galleon online UPS series delivers optimal power quality, provides superior power management, resolves utility power protection

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Electrical Measuring Instruments

Electrical Measuring Instruments Electrical Measuring Instruments Index Contents: Page Measuring Centres MC 320 Energy meter, MC 330 Multimeter 3 MC 760/UMC 760 Network Analyzer, MC 750/UMC 750 - Network Recorder 5 MC 740 Multifunction

More information

Eaton s E-Series protective relay family

Eaton s E-Series protective relay family E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family

More information

Polyphase kwh Electricity Meter

Polyphase kwh Electricity Meter Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Panorama Electricity meters For reliable values of energy consumption

Panorama Electricity meters For reliable values of energy consumption Panorama Electricity meters For reliable values of energy consumption Why measure Electrical Energy Energy cost is on the rise. It is therefore in the interest of both private and commercial customers

More information

Power management. PowerLogic System. Catalogue 2004

Power management. PowerLogic System. Catalogue 2004 Power management PowerLogic System Catalogue 2004 PowerLogic System is PowerLogic System helps you control the cost, quality and reliability of electric power. With PowerLogic System, you can determine

More information

Kit 106. 50 Watt Audio Amplifier

Kit 106. 50 Watt Audio Amplifier Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

Multi-Function Ground

Multi-Function Ground Multi-Function Ground Resistance SOIL RESISTIVITY TEster Model 6470-B Now measure ground resistance, soil resistivity and bonding resistance with one instrument! 2- and 4-Wire Bond Resistance/Continuity

More information

SYSTEM MONITORING Locally and remotely

SYSTEM MONITORING Locally and remotely StecaGrid 300 StecaGrid 500 StecaGrid 2000+ StecaGrid 2010+ StecaGrid 2020 StecaGrid 3000 StecaGrid StecaGrid 4200 StecaGrid StecaGrid 10000+ 3ph StecaGrid 8000 3ph StecaGrid 10000 3ph monitoring StecaGrid

More information

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch

More information

Managing. Energy management and power analysis

Managing. Energy management and power analysis management and power analysis Power monitors IN 96 and 144 - Selection table... 68 - IN 96, recdigit NOUS... 70 - IN 144, recdigit POWER... 72 - Multi-display recisplay... 73 Winthor software... 74 Managing

More information

ENERGY AUDITING AND MONITORING IN COMPANIES

ENERGY AUDITING AND MONITORING IN COMPANIES ENERGY AUDITING AND MONITORING IN COMPANIES Introduction To implement Article 8 (-6) of the EU Energy Efficiency Directive (0/7/EU), the UK government has set up ESOS (Energy Savings Opportunity Scheme)

More information

Preset Counter signo 721

Preset Counter signo 721 Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with SOLAR MICRO INVERTER 260 COMMUNICATI GATEWAY Apparent Power Control (APC) P Q unique micro inverter with REAL & REACTIVE POWER CTROL 2 Micro Inverters unique micro inverter with real & reactive power control

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, 18 80 W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, 18 80 W Compact and T5c fluorescent lamps Product description Noise-free precise control via DSI signal or switchdim CELMA energy class A1 1) Interfaces DSI switchdim Integrated SMART-Interface Functions Optimum filament heating in any dimmer

More information

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE Perfect Welding Solar Energy Perfect Charging FRONIUS ENERGY PACKAGE The personal storage solution for 24H Sun. PC board replacement process SnapINverter technology Integrated data communication Dynamic

More information

Model 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Model 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances

More information

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output

More information

One Meter Works for Both Energy Saving and Power Quality Surveillance

One Meter Works for Both Energy Saving and Power Quality Surveillance Multi-Function Meter Eco-POWER METER W9M SERIES Conforming to ow Voltage and EMC Directives One Meter Works for Both Energy Saving and Quality Surveillance High accuracy: 0.2 %* Harmonic measurement* Simple

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Electronic sensor

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

40.3. Control Relays and Timers

40.3. Control Relays and Timers .3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories

More information

THERMAL ENERGY METER MC 108/ET

THERMAL ENERGY METER MC 108/ET USCITE CONTATORE DI CALORE CONVERTITORE SENSORE ELETTROMAGN. EUROMAG CONTATORE DI ENERGIA TERMICA PORTATA: SENSORE ELETTROMAGN. uscite: TEMPERATURE: Pt 100 4-20 ma potenza termica 4-20 ma temperatura ta

More information

Low Voltage Products

Low Voltage Products Low Voltage Products ABB Power Quality Filters: The most efficient solution for active filtering of harmonics, smooth reactive power compensation and load balancing. Enabling trouble-free and efficient

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps EXCEL oneall series Product description Noise-free precise control via DSI signal, switchdim, corridorfunction or DALI DALI-MEMORY Extended DALI commands CELMA energy class A1 1) Interfaces DALI DSI switchdim

More information

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0

Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0 The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection,

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

Installation and operating instructions

Installation and operating instructions English Installation and operating instructions Energy meter 3-phase CETS-A via up to 1500A Description The CETS-A is a compact electronic active power energy meter for application in 3-phase power lines

More information

Digital multimeters DMG 600-610

Digital multimeters DMG 600-610 Digital multimeters DMG 600-610 Digital multimeters DMG 600-610 are capable of viewing the measurements with high accuracy on the wide LCD display, which allow to control energy distribution networks.

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Measurement and Instrumentation

Measurement and Instrumentation POWER QUALITY ENERGY PERFORMANCE Measurement and Instrumentation Transformers and shunts Transformers Overview of ranges Selection guide Info & advice Standard industrial transformers TCR TCRO ranges Adaptable

More information

Contents. Energy saving screen saver. Harmonics measurings up the 15 th or 50 th. Relays with OR option. 0.5% accuracy in voltage and current

Contents. Energy saving screen saver. Harmonics measurings up the 15 th or 50 th. Relays with OR option. 0.5% accuracy in voltage and current CVM system analyzers M5 M.5.01 GB Contents Page Introduction 3 Three-phase system analyzers 4 Applications 5 Three-phase system analyzers CVM-NRG 96 6 CVM-96 7 CVM-144 8-9 CVMk 10-11 Analogue I/O equipment;

More information

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219 Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)

More information