PARKVILLE HIGH SCHOOL LIMITED RENOVATION



Similar documents
Schematic Design Presentation S. Dallas Dance, Superintendent October 22, 2013 OVERLEA HIGH SCHOOL

BUNKER HILL ELEMENTARY SCHOOL

PLUMMER ELEMENTARY SCHOOL

ORANGE UNIFIED SCHOOL DISTRICT SCHOOL FACILITIES MASTER PLAN NEEDS ASSESSMENT

HAMILTON SCHOOL Brentwood Parkway, N.E., Washington, DC INITIAL YEAR BUILT 1968 BUILDING AREA

MURCH ELEMENTARY SCHOOL

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

HOUSTON ELEMENTARY SCHOOL

DRAPER ELEMENTARY SCHOOL

ORANGE UNIFIED SCHOOL DISTRICT SCHOOL FACILITIES MASTER PLAN NEEDS ASSESSMENT

SECTION XI OPINION OF PROBABLE COST

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.

Chicago Public Schools

A Residential Owner s Guide to PERMITS. Elgin CITY OF PLANNING & NEIGHBORHOOD SERVICES

SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST

PATTERSON ELEMENTARY SCHOOL

Facility Assessment for East Main Street, Huntley, IL

May 5, Client Client Address. Re: Inspection Address, Chicago, Illinois. Dear Mr. Client,

KIEWIT CM/GC Enabling/Utilities

DAVIESS COUNTY SCHOOLS DISTRICT FACILITIES PLAN

Mequon - Thiensville School District Long Range Facilities Plan Monthly Project Schedule

Cherokee Trail High School East Arapahoe Road Aurora, Colorado 80016

INTRODUCTION COST AND FEASIBILITY OF RENOVATING OR REPLACING AN OLD SCHOOL BUILDING

Building Condition Assessment Report

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

2.4 Hardcopy submittals shall be provided at adequate size so that all notes are readable.

Presentation to Senate Select Committee on Government Facilities: Deferred Maintenance for State Supported Living Centers and State Hospitals

HOMEOWNER S PERMIT GUIDE

1. Maintenance. Mechanical, Electrical & Plumbing Improve ligh>ng control an sensoring $230,239

9770 CULVER BOULEVARD CULVER CITY, CA Incidental improvements: improvements that do not qualify as minor or

Facility Assessment Report, Montgomery Independent School District

Lindsay Thurber Comprehensive High School Red Deer School District No. 104 School Facilities Evaluation Project Page 1

July 29, Revise Section 1.1 (BACKGROUND AND CONTEXT) to the following:

HOUSING QUALITY STANDARDS (HQS)

Cedarfield Plantation

17,280 square feet Overview:

Slavic Village Building Condition Review

New Jersey City University Gilligan Student Union Center

Facilities Operations Customer Service Standards WORK ORDER PRIORITIES

Description of Project Statewide Student Data Warehouse

NORTH PENN HIGH SCHOOL RENOVATIONS

Building Permits: When are they required?

ST. MONICA FOOD PANTRY HOUSTON, TEXAS

OPEN ITEMS LIST - CONSTRUCTION Project Name: East Central Middle School - Jackson County CLA#: 11003

48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No.

Schedule B to By-law

How To Check For A Deficiency

Orlando Home Inspection Services

Town of Sandwich Facilities Department Summary of Building Repairs from Prior 5 7 Years List Updated August 7, 2015

Self-Home Inspection Checklist

Scituate Public Facilities Master Plan Final Report to the Board of Selectmen

Saint Cloud Business Center

October 5, 2015 Dear Client,

ELIGIBLE REPAIR PROJECT PARAMETERS

The work has continued on final Phase 4 and is nearing completion.

Memorandum. July 16, To: Plan Commission City of Madison

COMPREHENSIVE PROPERTY INSPECTIONS

29 Broadway- 14 th Fl Tel: New York NY Fax: Due Diligence Report. New York, New York

This report presents the findings and recommendations of the assessment of energy use and

APPLICATION FOR NEW CONSTRUCTION

Items in red were complete Items in green were complete on Lined out items are Life Safety Codes.

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

EAST LYME HIGH SCHOOL

VJ ASSOCIATES 1825 K STREET NW, #1100 WASHINGTON, DC TEL: (202) INITIAL PROJECT COST ANALYSIS

Building Condition Assessment: West Lexington Street Baltimore, Maryland

OPTIMUS WORK CLASSIFICATION LIST ENTER ALL THAT APPLY

Article 11. Window Replacement Project Norman E. Day & Col. John Robinson Elementary Schools

Current as of 11/10/08 1 of 1

Page 1 of 6 COMPLIANCE CHECKLIST. > Long Term Care Facility - Nursing Unit

Building Condition Assessment: North Howard Street Baltimore, Maryland

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

The City of Basehor, Kansas

PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW

How to report a repair

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

Sustainable Strategies for Rehabilitation Projects: 9th Street Office Building Adaptive Reuse Case Study

1/9/2015 P:\ \Project Management\Program\Ripon Space Program - 7 January 2015.xlsx

How To Build A Backwater Valve

C I T Y O F P E A R S A L L

COOK PHYSICAL SCIENCE BUILDING RENOVATIONS. Engineering & Architectural Services CONCEPT DESIGN MAY 11, BVH Project No.

Virginia. American Recovery and Reinvestment Act. 83 DoD Projects ($ 75.7M) Completed or Under Way by August 31, 2009

E X I S T I N G F A C I L I T I E S

Building Condition Assessment Report

Code Requirements for Existing Buildings

Inspection Item COMMENTS

LOS ANGELES AFB, EL SEGUNDO, CA:

Transcription:

PARKVILLE HIGH SCHOOL LIMITED RENOVATION DESIGN BRIEFING For Dr. Joe A. Hairston BALTIMORE COUNTY PUBLIC SCHOOLS August 11, 2009 Smolen 3 Emr + Associates Architects 1355 Piccard Drive, Suite 200 Rockville, MD 20850 0

DESIGN TEAM ARCHITECT Smolen 3 Emr + Associates Architects 1355 Piccard Drive Rockville, Maryland 20850 STRUCTURAL ENGINEER Columbia Engineering Inc. 6470 Dobbin Road Columbia, MD 21045 CIVIL ENGINEER KCI Technologies, Inc. 936 Ridgebrook Road Sparks, MD 21152 KITCHEN CONSULTANT Nyikos Associates 18205-A Flower Hill Way Gaithersburg, MD 20879 MECHANICAL, ELECTRICAL, PLUMBING ENGINEER James Posey Associates 3112 Lord Baltimore Drive Baltimore, MD 21244 COST ESTIMATOR KCI Technologies, Inc. 936 Ridgebrook Road Sparks, MD 21152 1

PROJECT DESCRIPTION PROJECT SCOPE Scope includes the original building (not the 1998 addition) Site Improvements: Systemic Improvements: Architectural Improvements: Physical repairs HVAC Building Facility Drainage Plumbing Life Safety Accessibility Electrical Accessibility Programmatic 2

PROJECT DESCRIPTION PSCP/IAC Limited Renovation This project is a Limited Renovation project in accordance with the PSCP/IAC guidelines The scope of work has therefore been categorized into the Limited Renovation Categories Categories Structural Systems Mechanical Systems Electrical Systems Fire Safety Conveying Systems Educational Enhancements Original Building Constructed in 1957 The facility is structurally sound (with limited exceptions) This project includes upgrades to make this school serviceable for another 30 to 50 years 3

EXISTING SITE PLAN EXISTING SITE PLAN The work associated with this project includes only the original building and does not include work associated with the 1998 Area "B" addition. 4

PROJECT DESCRIPTION This project is a Limited Renovation project in accordance with the PSCP/IAC guidelines The scope of work has therefore been categorized into the Limited Renovation Categories Structural Systems Site Related Replacement of damaged site paving and curbing Cleanout and repair storm water management systems Replacement of a failing retaining wall adjacent to the auditorium Building Exterior (Skin) Replacement of window curtain wall system and windows throughout the entire facility Replacement of all exterior doors Repointing of deteriorated areas of exterior brick Building Structural Demolish and rebuild auditorium dressing rooms due to structural failure Repair several bus loop canopy columns that are damaged Repair interior masonry walls 5

EXISTING SITE PHOTOS DETERIORATION OF PAVEMENT FAILING RETAINING WALL WASHOUT CLOGGED STORM DRAIN BROKEN CONCRETE WALKS TRASH BINS SCATTERED 6

CURTAIN WALL SYSTEM MORTAR JOINT FAILURE EXTERIOR DOORS NON-OPERABLE WINDOWS 7

PROPOSED ELEVATION Proposed Front Elevation (South Elevation) Concept (Not to scale) New Building connection between A' Building and Main. Mechanical Room Addition 2nd floor Existing Auditorium repointing of brick as required. New Curtain Wall System High Performance Glazing, Thermally Broken Aluminum Support System A Building Completely Renovated Defined Main Entrance Replacement of All Exterior Doors Auditorium Support Space Addition Construction Concept Aluminum Curtain Wall Concept Detail (2 story Mec. Above) 8

FIRST FLOOR MAIN BUILDING AUDITORIUM STAGE SUPPORT (Not to scale) WALL FAILURE INTERIOR MORTAR DETERIORATION BENT CANOPY COLUMN 9

PROPOSED SITE PLAN PROPOSED SITE PLAN 1. Replacement of damaged site paving and curbing 2. Cleanout storm water management systems 3. Replacement of failing retaining wall adjacent to the auditorium 4. Provide ADA compliant handicap accessibility to recreational fields across Putty Hill Avenue and to lower play fields. 5. Repave parking lot adjacent to A building and across the street parking at fields. 10

PROJECT DESCRIPTION This project is a Limited Renovation project in accordance with the PSCP/IAC guidelines The scope of work has therefore been categorized into the Limited Renovation Categories Mechanical and Plumbing Systems Upgrade mechanical system to all year round climate control thru central heating and central cooling. Replacement of building exhaust system. Replacement of above grade plumbing piping, including sanitary sewer, storm water, natural gas, and domestic hot/cold water systems. Replacement of all plumbing fixtures located throughout the original building due to age. Electrical Systems Fire Safety Replacement of switchboard Replacement of panelboards and branch circuits Replacement of all interior lights Replacement of all exterior building lights Replacement of light controls Install sprinkler system throughout the entire building. Replacement of all doors and hardware All stairwell doors to be placed on magnetic hold opens 11

Mechanical Systems Upgrade mechanical system to all year round climate control thru central heating and central cooling. Replacement of building exhaust system. EXISTING COOLING TOWER WINDOW AC UNIT WINDOW AC UNITS 12

Plumbing Systems ANTIQUATED FIXTURES Replacement of above grade plumbing piping, including sanitary sewer, storm water, natural gas, and domestic hot/cold water systems. Replacement of all plumbing fixtures located throughout the original building due to age. Install sprinkler system throughout the entire building. 13

Electrical Systems EXPOSED ELECTRICAL JUNCTION BOX COMPUTER DEMAND ON ELECTRICAL SYSTEM Replacement of switchboard Replacement of panelboards and branch circuits Replacement of all interior lights Replacement of all exterior building lights Replacement of light controls 14

PROJECT DESCRIPTION This project is a Limited Renovation project in accordance with the PSCP/IAC guidelines The scope of work has therefore been categorized into the Limited Renovation Categories Conveying Systems Elevator addition in the original building Miscellaneous Systems and ADA Provide ADA compliant handicap accessibility to recreational fields across Putty Hill Avenue Reconfiguration of at least one door alcove into each classroom to be ADA compliant. Renovation of gang restrooms to be in compliance with ADA guidelines Renovation of one staff restroom on each floor to be in compliance with ADA guidelines Limited renovation of both the boys and girls locker rooms to provide a minimum of one ADA compliant shower area, locker and bench area, toilet stall and sink. Limited renovation of team rooms to provide a minimum of one ADA compliant shower area, locker and bench area, toilet stall and sink. Provide ADA compliant room signs Install ADA compliant lift to music suite Replacement of all corridor lockers 15

PROJECT DESCRIPTION This project is a Limited Renovation project in accordance with the PSCP/IAC guidelines The scope of work has therefore been categorized into the Limited Renovation Categories Educational Enhancements Renovation of CTE labs in A Building Relocation of Nutrition & Food Science and Childcare Services programs into A Building Renovation of several computer labs in main building Reconfigure of three standard classrooms into two computer labs on the third floor Renovation and grouping of all Art room curriculum Renovation of health suite to MSDE guidelines Renovation of five existing science labs on the first floor Renovation of two large classrooms on the second floor into a new science lab Addition for the missing program spaces to support the auditorium program Renovation of cafeteria serving lines and addition of a serving line Renovation of kitchen layout, and equipment 16

Educational Enhancements PROGRAM DISTRIBUTION PLAN Renovation of A Building CTE Program Relocation of Nutrition & Food Science and Childcare Services Art room curriculum clustered together Renovation of health suite Renovation of five existing science labs on the first floor Renovation of kitchen, serving lines and addition of a serving line Addition for the missing program spaces to support the Theatrical Arts 17

Educational Enhancements PROGRAM DISTRIBUTION PLAN Renovation of several computer labs in main building Reconfigure of three standard classrooms into two computer labs on the third floor. Renovation of administration support areas on both floors Renovation of two large classrooms on the second floor into a new science lab and classroom 18

PARKVILLE HIGH SCHOOL LIMITED RENOVATION DESIGN BRIEFING For Dr. Joe A. Hairston BALTIMORE COUNTY PUBLIC SCHOOLS August 11, 2009 Smolen 3 Emr + Associates Architects 1355 Piccard Drive, Suite 200 Rockville, MD 20850 19