...een product van BEKA



Similar documents
MANTA Piston Distributor for Oil and Fluid Grease

Stove Guard Kit User Manual

GROENEVELD AUTOMATIC GREASING SYSTEMS

WE-350 Series ¼ Turn Electric Actuator

Mureva Assembly surface mounted wiring devices

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)


POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

HERZ-Thermal Actuators

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

OS Instruction Manual. Electronic Controllers for Reverse Osmosis Plants. Software version

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

COMPALARM AP GENERAL MAIN FEATURES

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

ELECTRIC CENTRAL HEATING FLOW BOILER

Cable Plug acc. to DIN EN , Form A

Installation & User Manual Radio Remote rev1.0.3

Water Leak Detection System

Product and Application Description

Mobile Data Power Model: MDP-25

COLOR VIDEO DOOR PHONE CDV-71BE/D

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL H2639IP-1

StructureScan HD Module. Installation Guide ENGLISH

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Digital Ignition ZDG3

Manual for Fire Suppression & Methane Detection System

Overheating limit control

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Product and functional description

4/2-Way Pneumatic Solenoid Valve

Introduction. Drenth Motorsport Gearboxes Fleuweweg AG Enter The Netherlands Phone: +31 (0) Fax: +31 (0)

Combi switchbox with integrated 3/2 way pilot valve

LED...A Q Series Sealed High-Intensity

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

Wiper Motor Marinco 2.5. Installation Instructions

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Instruction Manual for Operating Panel 301 and 302

SingleLine F212164R00

is then retained absolutely without interruption.

instabus KNX / EIB System System E F G H

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Operating Manual. Rotary Drum Filter. Technology You Can Afford. Quality You Can Trust. Model: KC10 KC15 KC30 KC60

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

Timken C-Power Multi-Point Lubricator Operating System Manual

Manual. Simrad StructureScan LSS-1 Sonar Module. English

SINGLE LINE CRENTRALIZED LUBRICATION SYSTEM

MCT-7 Multiple Cable Test System

Multi-Protocol decoder with Load regulation

TS93 EMR T/PT/TDE. Surface applied door closer

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

Installation & Maintenance Instructions Joystick- single Joystick - double Touch panel Wireless remote control

AUTODIALLER / QUICKDIALLER - SA132

GAE953 Electrical Alarm Unit 19" with Indicator

SECURITY SYSTEM ADP-CAN

ELECTRIC BICYCLE USER MANUAL

Modular I/O System Analog and Digital Interface Modules

15 Series - Electronic step relay and dimmer. Features SERIE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

IP Box Camera ACM Ver Hardware User s Manual

CG PTFE Diaphragm Liquid Transfer Pump

Proximity Switches RS (Reed Switch)

Telefon (+45) Telefax (+45) Installation and operating manual

User Manual: C Long Point Houston, TX Facebook.com/CoolAZone Twitter.com/CoolAZone

DALI RC BASIC SO. Control unit Operating instructions

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Electronic Pressure Switch EDS 300

TMS TANK MANAGEMENT SYSTEM

SET-UP AND TECHNICAL MANUAL

Models CT-001, CT-002 Owner s Manual

DVI 980/982 (Honeywell Nr. S4865) Gas Burner Safety Control

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

PSACH v.1.0 PSACH 24VAC/6A/1x6A HERMETIC AC power supply for CCTV

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Video Keyboard Mouse Audio automatic Switch CAS-241, CAS-441, CAS-441-PM

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

AL900 USER MANUAL. GPS Vehicle Tracker. User Manual V5.5 AL900. Page 1 of 19

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Technical Information

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

i ChatterBox! Motorcycle Security

User Manual. Before installation and use, please read the user manual carefully.

CT-001, CT-001-Solar Owner s Manual

How To Use A Power Supply On A Powerline 2.2 (Ai)

Mounting and Operating Instructions. TV gateway

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Transcription:

Integrated electric controller S-EP with Hirschmann connector Contents Page EP- pump with integrated controller S-EP Algemeen. Functional features. Time control -. Stroke control Supplementary functions. Grease level monitoring. Permanent error notification. Pressure relief valve with microswitch Summaries. Terminal diagram. Ordering key pump 9 9. Ordering key integrated controller 9 BEKA-MAX. Functional features The integrated electric controller S-EP is used for the time- or cycle-dependent control of a central lubrication device. This controller can be used for progressive systems (EP- pumps) and multi-line systems (OC pumps). Integrated controller S-EP The integrated electric controller S-EP is available with types of control: A) Time control B) Stroke control The type of control must be indicated when ordering. showing function After turning on the ignition, regardless the preset program, the yellow LED illuminates for, sec. and indicates that the controller is in operation (standby indicator). Button for activating interim lubrication Standby indicator:, sec..0.

S-EP with Hirschmann connector. Time control When operating the button on the side of the casing, or the external button, the lubrication system is brought into operation and the pump is running. When the lubrication cycle is completed, the pump stops and the interval time begins. The lubrication cycles are automatically initiated according to the set lubrication or interval time. When the ignition is switched off during the lubrication or interval time, the cycle is stopped and the data is stored. When the ignition is switched on again, the operation process will continue from the point where it was interrupted. Diagram of cycle sequence: lubrication time interval time Integrated controller S-EP After switching on, an interim lubrication can be initiated by pushing the button on the side of the casing of the pump. Pushing the button can also be used to check if the pump is in operation. The pump will immediately start a lubrication cycle. The elapsed or stored lubrication or interval time will be reset and the pump will start over. An interim lubricationcan also be initiated by using an external button. The output signals of the yellow LED can also be indicated by a signal lamp in the drivers cabin (option). Rotary code switch for setting the interval time Rotary code switch for setting the lubrication time Button for activating interim lubrication showing function Before connecting the pump to the electrical system, please observe the voltage of the pump motor. Lubrication process: 0. sec. 0. sec. Terminal diagram for external signal lamp: Terminal diagram for external button: button interim lubrication yellow green signal lamp - Ground, terminal - Ground, terminal Ignition, terminal F F =, A (x0) medium slow-blow Ignition, terminal F F =, A (x0) medium slow-blow

S-EP with Hirschmann connector. Time control (continuation) Technical data: Operating voltage: 0-0 V Max. power load: I =,0A Fuse (not included in device): F, A(x0) slow-blow Output signal lamp: I = A Temperature range: - C to C Protection class: IP The controller is available with different lubrication time ranges: to min. or to min. The interval time will remain the same. The time range must be indicated when ordering. The lubrication time and the interval time can be set by adjusting the rotary code switches positioned behind the viewing window of the controller. To adjust these setting, the red frame of the viewing window, has to be removed with a flat screwdriver. Then the Phillips screws have to be loosened and the viewing windows removed. If the wiewing window and the red frame are improperly installed, water can enter the controller which may cause a malfunction. This will void the warranty. Setting the parameters Interval time: 0. to h notches notch = 0. h 0, Lubrication time: Time range I: to min. notches notch = min. 0 Time range I I: to min. notches notch = min. 0

S-EP with Hirschmann connector. Stroke control The S-EP controller can also be delivered as a stroke controller, for monitoring a progressive greasing system. In this case a proximity switch is attached to the progressive ditributor. The proximity switch converts the piston strokes into electrical signals and transmits them to the S-EP controller. Integrated electric controller S-EP The number of strokes ( t/m ) can be set by adjusting the rotary code switche positioned behind the viewing window of the controller. After setting the interval-time, the lubrication system is brought into operation and the pump is running. After reaching the set number of strokes, the pump stops and the interval time begins. The stroke controller pulsbesturing has amonitoring time of min. and 0 sec., i.e. each piston stroke of the progressive distributor must be completed within min. and 0 sec.. If this is not the case, the control indicates a malfunction and the yellow LED starts blinking. Lubrication in process: 0. sec. 0. sec. Button for activating interim lubrication showing function Rotary code switch for setting the interval time Rotary code switch for setting the lubrication time Controller with plug for proximity switch (bottom view): Malfunction strokes: 0. sec.. sec. 0. sec.. sec. Plug for connecting the proximity switch Distributor with attached proximity switch: Plug for connecting the pump to the power supply Wiring diagram: Technical data proximity switch: - Ground, terminal Ignition, terminal F F =, A (x0) medium slow-blow Operating voltage: 0-0 V DC Connecting method: PNP-turnkey Max. current load: 00 A Connection: Mx plug Indicator operation/malfunction: yellow LED Housing material: stainless steel Protection class: IP Temperature range: -0 C to C

S-EP with Hirschmann connector. Grease level monitoring Grease pumps can also be equipped with grease level monitoring. Therefore, a capacitive proximity is installed into the pump reservoir. If the lubricant sinks below minimum the signal send to the S-EP controller changes. Reservoir of a EP- pump with grease level monitoring Technical data capacitive proximity switch: Operating voltage: 0-0 V DC Connecting method: PNP-contact Protection class: IP Temperature range: - C t/m 0 C Connection: compact plug on reservoir Pole alocation: nr. = 0-0 V DC nr. = ground nr. = NC contact = vacant Min. level capacitive proximity switch If the grease level is too low, the controller registers the signal. If the pump reservoir remains empty for more than 0 sec., the pump stops and the red LED blinks slowly. As soon as the reservoir is filled again, a lubrication cycle can be started by pushing the button of the controller. In order to connect the level monitoring to the built-in electronic controller S-EP, the controller is equipped with a second plug connector. Om de niveaubewaking aan te sluiten aan de ingebouwde elektronische besturing S-EP, is de besturing voorzien van een tweede stekkeraansluiting. The grease level control can be ordered in both time- or stroke controlled devices. Applying grease level monitoring must be specified when ordering.. Wiring diagram: Signal grease level too low: sec. sec. - Ground, terminal Ignition, terminal Controller with plug for grease level monitoring (bottom view): Plug for connecting the grease level monitoring Plug for connecting the pump to the power supply

S-EP with Hirschmann connector. Permanent error notification As an option the S-EP controller can also be equipped with a permanent error notification. In this case when an error occurs, the external signal lamp does not blink but provides a constant signal. With the help of an external lamp or horn, this signal will warn when an error occurs. The lamp burns continuously or the horn emits a signal, until the error is corrected. The yellow LED behind the viewing glass on the controller indicates, with the normal blinking frequencies, the operating status of the controller. The lamp, horn and connecting cable are not included when ordering. Technical data: Outlet permanent error notification: A Wiring diagram: - - Ground, terminal Ignition, terminal F F =, A (x0) medium slow-blow

S-EP with Hirschmann connector. Pressure relief valve with microswitch As an option the S-EP controller can be used to monitor the max. operating pressure of a progressive lubrication system. To achieve this, a pressure relief valve with microswitch is fitted to the pumpelement. In case of a malfunction e.g. caused by the blockage of a lubrication point, the pressure will built up of more than 0 bar. This causes the pressure relief valve in operation and ratifies the microswitch, which emits a signal to the controller. The pump is turned off by the controller and the yellow LED blinks indicating a malfunction. Pressure relief valve with microswitch on a pumpelement installed in an E P- pump microswitch Technical data microswitch: Operating voltage: 0-0 V DC Max. power load: I =, A Connecting method: changeover switch Protection class: IP Temperature range: - C to 0 C Before connecting the pump to the electrical system, please observe the voltage of the pump motor. A pressure relief valve with microswitch cannot be installed on a standard S-EP controller, as this would require plug connectors. If a pumpelement has to be equipped with a pressure relief valve with microswitch, this has to be indicated when ordering. Wiring diagram of a microswitch on the S-EP controller: Error indication microswitch: sec. :vrij - Ground, terminal Ignition, terminal sec.

Plug for connecting the proximity switch, the microswitch and the grease level monitoring...een product van BEKA S-EP with Hirschmann connector. Terminal diagram Pressure relief valve with microswitch Permanent error notification switching yellow signal lamp green button interim lubrication - Ground, terminal F Ignition, terminal F =,A (x0) medium slow-blow proximity switch for stroke control Grease level monitoring Plug for connecting the pump, external button and external signal lamp to the power supply

S-EP with Hirschmann connector. Ordering key EP- with integrated controller S-EP Construction type Motor voltage V Outlet position V 0 0 0 PE-0 PE-0 V PE-0 PE-0 Without Other combination on demand! Size of reservoir (kg),9 Code 00 00 0 00 0 0 Code G U J parts, 00 00 0 00 0 part Code K L M 9 00 00 0 00 0 Code N P Q V W 00 00 0 00 0 Spec. uitv. Code R S T X Y Z I Order example: Outlet position: : Code:. X. X. X. X. X. XX Lubricating time l to min. ll to min. Button Yes No Code 0 00 Special models 0 0 Special models: 0 = Grease level monitoring connected to the controller 0 = Grease level monitoring not connected to the controller 9. Ordering key integrated controller S-EP for EP- and OC- Construction type. 9000. X. X. 00 Lubricating time l to min. ll to min. Button Yes No Code 0 Special model 00 9