1 EN Installation & User Manual Radio Remote rev1.0.3 RC-20E RC-21E RC-22E RC-23E SLEIPNER MOTOR AS P.O. Box 519 N-1612 Fredrikstad Norway Tel: Fax: Made in Norway Sleipner Motor AS 2015
2 Contents Model range... 2 Technical specifications... 3 Important precautions... 3 Receiver installation... 4 User precautions... 6 How to use RC20E... 7 How to use RC21E... 8 How to use RC22E... 9 How to use RC23E Transmitter LED operation and alarm indication Electric diagram Output signals diagram Programming additional transmitters Replacing transmitter battery Dimensions Model range The radio remote control can control a single bow thruster/windlass or a bow and stern thruster/ windlass combined. The receiver can receive the signals of up to four transmitters. Remote control kit RC-20E consists of: - Receiver: Part no. RCR-2E - Transmitter (incl. battery): Part no. RCT-20E - Holding bracket for transmitter unit: Part no. RC-HOLDER Remote control kit RC-21E consists of: - Receiver: Part no. RCR-2E - Transmitter (incl. battery): Part no. RCT-21E - Holding bracket for transmitter unit: Part no. RC-HOLDER Remote control kit RC-22E consists of: - Receiver: Part no. RCR-2E - Transmitter (incl. battery): Part no. RCT-22E - Holding bracket for transmitter unit: Part no. RC-HOLDER Remote control kit RC-23E consists of: - Receiver: Part no. RCR-2E - Transmitter (incl. battery): Part no. RCT-23E - Holding bracket for transmitter unit: Part no. RC-HOLDER Additional transmitters can be ordered separately; The transmitter and the receiver have the same factory preset code so no programming is necessary. The battery is already inserted in the transmitter. When additional transmitters are to be used, the new transmitter(s) must be paired with the receiver (please see programming section). We Sleipner Motor AS declare that this device complies with health and safety requirements according to the Directives EN V1.4.1:2002 EN V1.4.1:2008 IEC 60533:1999 EN V2.3.1:2010 EN V2.3.1:2010 Installation & User Manual, Radio Remote rev 1_0_3 Page 2
3 Technical specifications Transmitter Receiver Power feed 1x3V battery (type: CR2032) 12V or 24V power source Frequency (MHz) 868MHz 868MHz RF-power <10mW <10mW Operation temp. -10 C / +55 C -15 C / +55 C HxWxD (mm) 107x47x21 83x136x36 Weight (g) Voltage 8-30V Load, max 4A Operating range 15m under normal operating conditions Important precautions With the boat on land, only run the thruster for a fraction of a second, as without resistance it will accelerate very fast to a damaging rpm. This manual is intended to support educated / experienced staff. When installed in boats approved or classified according to international or special national rules, the installer is responsible for following the demands in accordance with these regulations / classification rules. The instructions in this guide can not be guaranteed to comply with all different regulations / classification rules. The transmitter and the receiver have the same factory preset code so no programming is necessary. When additional transmitters are to be used, follow the instructions in the programming section on page 15. Installation & User Manual, Radio Remote rev 1_0_3 Page 3
4 Receiver installation Prior to installation, it is important that the responsible installer reads this guide to ensure necessary acquaintance with this product. WARNING! WARNING! Remote receiver power supply negative lead must be connected to the thrusters`s negative lead. Power to the thruster s must be switched off during installation! Install the receiver minimum 1 meter (3ft) from high power cables and data communication cables or other sources of electrical interference, i.e. navigation instruments, radio communication devices, electric motors and generators. Install the receiver minimum 1 meter (3ft) above sea level. Install the receiver outside of shielded areas for radio signals, i.e. boxes made of metals or other material with shielding properties. Install the receiver in a dry environment, where no condensation can enter the unit. (The receiver assembly is not waterproof.). Mount the receiver using the four holes (please see picture on page 5). The receiver must have a separate power supply fitted with a 5 Amp fuse in the positive lead that has either a separate power switch or is shut of by the thrusters system main power switch. The receiver can not be powered by the thrusters/windlass control looms even if you find positive and negative lead there. Connect the supplied wiring harnesses to the receiver unit according to the wiring diagram on page 13. Connect thrusters and windalsses to the appropirate connectors according to diagram. For use with other windlass brands, connections must be determined by the installer according to output signals diagram on page 14. NB: Max. load on the windlass signal output is 4A! If the windlass requires more than 4A, use extra control relay. Note! Faulty installation will render all warranty given by Sleipner Motor AS void. Installation & User Manual, Radio Remote rev 1_0_3 Page 4
5 D Mount the receiver by using the 4 holes. C B A Designed by Checked by Approved by olekr Installation & User Manual, Radio Remote rev 1_0_3 Page 5
6 User precautions Ensure that you know the location of the main battery switch that disonnects the thruster from all power sources (batteries) so that the thruster/windlass can be turned off in case of a malfunction. The maximum continues usage time of the electrical thruster is approx. 3 minutes. The electro motor has a built in thermal cut-off switch that will shut it off when overheating and re-engage it when it has cooled down some. This should be considered when planning your manouvering. Never use a thruster close to somebody in the water, as the thruster will draw objects close by into the tunnel and contact with the rotating propellers will cause serious injuries. Never use a windlass close to somebody in the water, an unexpectedly drop of the anchor can cuse serious injuries. If the thruster stops giving thrust while the electric motor is running, chances are that there is a problem in the drive-system. You must then immediately stop trying to run it, and turn it off, as running the electricmotor for more than a few seconds without resistance from the propeller, can cause serious damage to the electricmotor. When leaving the boat always turn off the main power switch for the thruster/windlass and turn off the power to the receiver. We advice to always keep the main engine(s) running while using a thruster/windlass. This will keep the batteries in a good charge condition. This will also give better performance to the thruster. It is the owner/captain/other responsible party full responsibility to assess the risk of any unexpected incidents on the vessel. If the thruster stops giving thrust for some reason while maneuvering you must have considered a plan on how to avoid damage to persons or other objects. Installation & User Manual, Radio Remote rev 1_0_3 Page 6
7 RC-20E Remote control ON Turn boat to Port Bow + Stern thruster Remote control OFF Turn boat to Starboard Auto-OFF appr. 4 min. Hold for 2 seconds How to use a bow/stern thruster 1. Turn the main power switch for the bow/stern thruster on. Turn on main switch so the receiver has power. 2. Turn on the transmitter by pushing the transmitter s two ON buttons. The remote system is now activated and then turns off automatically appr. 4 min. after the last usage. 3. Please take some time to exercise thruster usage in open water to avoid damages to your boat. 4. Turn the bow/stern in the desired directiony by pushing the red button for port movement or the green button for starboard movement. How to use a bow & stern thruster combined The combination of a bow and stern thruster offers total manouverability to the boat and the opportunity to move the bow and the stern separately of each other. The remote middle buttons gives you the opportunity to operate both thrusters in the same direction with one keypress, making sidewards movement easier. Remote Control Deactivation Push the transmitter s OFF button for 2 seconds (the remote control deactivates automatically after approx. 4 minutes after the last usage). If in doubt, try in open water first! Installation & User Manual, Radio Remote rev 1_0_3 Page 7
8 RC-21E Remote control ON Turn boat to Port Windlass Down Remote control OFF Turn boat to Starboard Auto-OFF appr. 4 min. Hold for 2 seconds Up How to use a bow thruster 1. Turn the main power switch for the bow thruster on. Turn on main switch so the receiver has power. 2. Turn on the transmitter by pushing the transmitter s two ON buttons. The remote system is now activated and then turns off automatically appr. 4 min. after the last usage. 3. Please take some time to exercise thruster usage in open water to avoid damages to your boat. 4. Turn the bow in the desired direction. By pushing the red button for port movement or the green button for starboard movement. How to use the windlass 1. Turn the main power switch for the windlass on. Turn on the power to the receiver. 2. Turn on the transmitter by pushing the transmitter s two ON buttons. The remote system is now activated and then turns off automatically appr. 4 min. after the last usage. 3. Please consult your windlass manual for use and precautions. Remote Control Deactivation Push the transmitter s OFF button for two seconds (the remote control deactivates automatically after approx. 4 minutes after the last usage). If in doubt, try in open water first! Installation & User Manual, Radio Remote rev 1_0_3 Page 8
9 RC-22E Remote control ON Windlass 1 Windlass 2 Down Down Remote control OFF Auto-OFF appr. 4 min. Up Hold for 2 seconds Up How to use a bow/stern windlass 1. Turn the main power switch for the windlass on. Turn on main switch so the receiver has power. 2. Turn on the transmitter by pushing the transmitter s two ON buttons. The remote system is now activated and then turns off automatically appr. 4 min. after the last usage. 3. Please consult your windlass manual for use and precautions. Remote Control Deactivation Push the transmitter s OFF button for two seconds (the remote control deactivates automatically after approx. 4 minutes after the last usage). Installation & User Manual, Radio Remote rev 1_0_3 Page 9
10 RC-23E Remote control ON Turn boat to Port Bow + Stern thruster Remote control OFF Turn boat to Starboard Auto-OFF appr. 4 min. Hold for 2 seconds Windlass 1 Down Up Windlass 2 Down Up Installation & User Manual, Radio Remote rev 1_0_3 Page 10
11 How to use a bow/stern thruster 1. Turn the main power switch for the bow/stern thruster on. Turn on main switch so the receiver has power. 2. Turn on the transmitter by pushing the transmitter s two ON buttons. The remote system is now activated and then turns off automatically appr. 4 min. after the last usage. 3. Please take some time to exercise thruster usage in open water to avoid damages to your boat. 4. Turn the bow/stern in the desired directiony by pushing the red button for port movement or the green button for starboard movement. How to use a bow & stern thruster combined The combination of a bow and stern thruster offers total manouverability to the boat and the opportunity to move the bow and the stern separately of each other. The remote middle buttons gives you the opportunity to operate both thrusters in the same direction with one keypress, making sidewards movement easier. How to use the bow/stern windlass 1. Turn the main power switch for the windlass on. Turn on the power to the receiver. 2. Turn on the transmitter by pushing the transmitter s two ON buttons. The remote system is now activated and then turns off automatically appr. 4 min. after the last usage. 3. Please consult your windlass manual for use and precautions. Remote Control Deactivation Push the transmitter s OFF button for two seconds (the remote control deactivates automatically after approx. 4 minutes after the last usage). Turn off the power switch for the receiver. If in doubt, try in open water first! Installation & User Manual, Radio Remote rev 1_0_3 Page 11
12 Transmitter LED operation and alarm indication State LED status Alarm status Transmitter ON Buttons activated The yellow LED s blink each second The yellow LED s blink fast No sound No sound Pairing mode All LED s on No sound Connection lost Red LED is blinking once each second Low battery Red LED blink One beep Receiver LED indicator 3 beeps from the buzzer each second State Power on the receiver and no transmitter connected Power on the receiver and at least one transmitter connected No power to the receiver. Receiver in pairing mode LED status Green LED is toggling Green LED lit Both LED is off Both the red and green LED blinking Installation & User Manual, Radio Remote rev 1_0_3 Page 12
13 Electric diagram To Thruster Control Panel To Thruster Control Panel BOW To Bow Thruster STERN To Stern Thruster BLACK RED FUSE 5A + - Battery 12/24V Remember! Power cables must be connected to the battery as shown. Remaining wires must be cable tied well. To Windlass Control Panel To Windlass Control Panel BOW To Bow Windlass STERN To Stern Windlass Installation & User Manual, Radio Remote rev 1_0_3 Page 13
14 Output signals diagram RED Thruster Positive BLUE Thruster STBD GREY Thruster PORT Thruster Bow YELLOW Automatic Mainswitch Enable RED Thruster Positive BLUE Thruster STBD GREY Thruster PORT Thruster Stern YELLOW Automatic Mainswitch Enable RED - COMMON BLUE Windlass IN GREY Windlass OUT Windlass Bow RED - COMMON BLUE Windlass IN GREY Windlass OUT Windlass Stern Installation & User Manual, Radio Remote rev 1_0_3 Page 14
15 Programming additional receivers Pair Button The original transmitter and receiver have the same factory preset code so that no programming is necessary. When additional transmitters are to be used, the additional transmitters has to be paired with the receiver. 1. Be sure that there is power on the receiver (Green status LED blinking) and that the transmitter that should be paired is off. 2. Push the Pair Button on the receiver to put the receiver in pairing mode (as shown above). Both red and green led s should start to blink simultaneously. 3. Within 10s after the receiver pair button is pushed, set the transmitter in pairing mode by holding the off button and pressing both ON buttons at the same time, all the transmitter LED s turn on indicating that it is set in pairing mode. When a pairing signal is received from the receiver the transmitter LED s while turn off and the system is ready to be used. If no pairing signal received within 10s the transmitter will leave the pairing mode. 4. Additional transmitters must be programmed according to step 2-3. You can pair up to 4 transmitters. 5. To clear all transmitters paired with the receiver hold the pair button on the receiver for approximately 10s until the red and green led stop blinking. When the LED s stop blinking release the pair button, the green led will again start to blink when the receiver has completed the reset process. The receiver is then ready to pair with up to four transmitters. Installation & User Manual, Radio Remote rev 1_0_3 Page 15
16 Replacing transmitter battery Battery B A A B WARNING: Before working on the transmitter, deactivate the transmitter and the receiver (push OFF on the transmitter(s)) and turn off the power to the receiver as well as the thruster mainswitch. 1. Open the transmitter case by removing the 3 torque screws. 2. Remove the battery by inserting a screwdriver or similar between battery and holder at point A, and gently flip the battery out, taking care not damaging the battery grips at point B. 3. Insert the new battery (Type CR2032, 3V - Brand name recommended). Be sure to insert the battery with the positive pole up diagonally into the battery holder, ensuring that the edge of the battery is under the battery grips (B). Press the battery down until secured at point A. 4. Close the transmitter. Put the cover back in place, ensure that the rubber seal between remote upper and lower part is located correctly. Place the 3 screws (remember sealing washer) in their recessed holes and tighten. Installation & User Manual, Radio Remote rev 1_0_3 Page 16
17 Dimensions F E 4,5 x4 6 D F C E B D C A NS-ISO Over t.o.m. f m c v B 0,5 3 ±0,05 ±0,1 ±0,2-3 6 ±0,05 ±0,1 ±0,3 ±0, ±0,1 ±0,2 ±0,5 ± ±0,15 ±0,3 ±0,8 ±1, ±0,2 ±0,5 ±1,2 ±2, ±0,3 ±0,8 ±2 ± ±0,5 ±1,2 ±3 ± ±2 ±4 ±8 Installation & User Manual, Radio Designed by Remote Material rev Type1_0_3 Date Drawing nr Page 17 olekr Copyright All rights reserved Generic Title Holder Holder Tolerance NS-ISO A
18 Installation & User Manual, Radio Remote rev 1_0_3 Page 18
19 Installation & User Manual, Radio Remote rev 1_0_3 Page 19
20 Worldwide sales and service SLEIPNER MOTOR AS P.O. Box 519 N-1612 Fredrikstad Norway Tel: Fax: The information given in the document was correct at the time it was published. However, Sleipner Motor AS can not accept liability for any inaccuracies or omissions it may contain. Continuous product improvement may change the product specifications without notice. Therefore, Sleipner Motor AS can not accept liability for any possible differences between product and document.
Installation & User Manual Radio Remote RC-10E
Installation & User Manual Radio Remote RC-10E SLEIPNER MOTOR AS P.O. Box 519 N-1612 Fredrikstad Norway Tel: +47 69 30 00 60 Fax: +47 69 30 00 70 www.side-power.com [email protected] Made in Norway
Installation & Maintenance Instructions Joystick- single Joystick - double Touch panel Wireless remote control
Installation & Maintenance Instructions Joystick- single Joystick - double Touch panel Wireless remote control NS-EN ISO 9001:2000 Art.nr. 117-00155 FCC ID: R78-RC-01 R78-ECU-01 XF Rev: 1-2008 Side 1 Contents
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
Instruction Manual for Operating Panel 301 and 302
Instruction Manual for Operating Panel 301 and 30 Edition: 1/006 Edition: 1/006 Contents 1 Introduction and Overview........................ 5 1.1 Panel 301 Controls........................................
Model SETR-50 and SETR-51 Trim Tab Control
Model SETR-50 and SETR-51 Trim Tab Control Pictured above is the SETR-50 with black switches on a gray background. The SETR-51 is identical except for the color, wherein it has black switches on a black
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable Port side cable (with black cable tie attached) Power cable Preparing for Installation 1 Overall
SIDE-POWER. SXP80/185T & SXP100/185T External sternthruster assembly. Installation and user manual. Thruster Systems. manual onboard!
SIDE-POWER Thruster Systems SXP80/85T & SXP00/85T External sternthruster assembly Keep this manual onboard! Installation and user manual SLEIPNER MOTOR AS P.O. Box 59 N-62 Fredrikstad Norway Tel: +47 69
Manual. Simrad StructureScan LSS-1 Sonar Module. English
Manual Simrad StructureScan LSS-1 Sonar Module English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Disclaimer As Navico is continuously improving this product, we retain the
StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com
StructureScan HD Module Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Disclaimer As Navico is continuously improving this product, we retain the right to make changes
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:[email protected] www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory Application Publications No. AII23628 2003 PILOT Issue Date MAY 2002 PARTS LIST Security System Kit (sold separately): P/N 08E51-S84-100 2 Remote controls Attachment
ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE
Emergency Response System INSTALLATION & PROGRAMMING GUIDE Copyright micron 2005 Contents Product Description 3 Console Operation Overview 4 Console Wiring Diagram 5 User Manual 6 Transmitter Assembly
RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4
RUST ELECTRONICS LTD Remote Switching Unit RCU-O4 MAINS REMOTE SWITCHING UNIT RCU-O4 The RCU-O4 is a radio remote controlled switching unit that will allow the remote operation of any appropriate electrical
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
POWER TRIM 5 F AUTO TRIM AND AUTO TRIM
POWER TRIM 5 F 22217 AUTO TRIM AND AUTO TRIM Table of Contents Page Auto Trim System........................ 5F-1 Description........................... 5F-1 Auto Trim Operation...................... 5F-2
FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON
FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON SERIAL NUMBER Flash Technology, 332 Nichol Mill Lane, Franklin, TN 37067 (615) 261-2000 Front Matter Abstract This
KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER
KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER DEALER SERVICE AND INSTALLATION MANUAL KIT NO. 00016-30915 Contents PARTS LIST... 2 PARTS ILLUSTRATIONS... 2 VEHICLE PREPARATION... 3 INSTALLING
Triac Printed Circuit Board Replacement
Technical Service Bulletin: Triac Printed Circuit Board Replacement TRONIC 5000C Pro Models: WH17, WH27, WH36 Introduction Fig. 1 ELECTRICITY IS EXTREMELY DANGEROUS. TAKE EXTRA PRECAUTIONS AND ENSURE ALL
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
Inwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
RMK-9. Installation and Operation instructions. ENGLISH Date: 04-2013 Document number: 81351-1-EN 2013 Raymarine UK Limited
RMK-9 Installation and Operation instructions ENGLISH Date: 04-203 Document number: 835--EN 203 Raymarine UK Limited ENGLISH Document number: 835- Date: 04-203 Handbook information This handbook contains
Product and Application Description
Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
ANTI-THEFT SYSTEM. 1995 Volvo 850 DESCRIPTION & OPERATION BASIC ALARM. 1995-96 ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems
ANTI-THEFT SYSTEM 1995 Volvo 850 1995-96 ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems 850 DESCRIPTION & OPERATION WARNING: Deactivate air bag system before performing any service operation. For 1995
162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL
162 CB CABLE TRACER Filter Probe & Tone Generator INSTRUCTION MANUAL INDEX PAGE 1. INTRODUCTION... 1 2. FILTER PROBE... 1-3 3. TONE GENERATOR... 3-6 4. SPECIFICATION... 7-8 5. MAINTENANCE... 8 1. INTRODUCTION
4.3-inch Back-Up Camera
TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION
DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0
Form No. 74-00-4001 S168-195-001 Revision E DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0 INTRODUCTION Allied Healthcare Products, Inc. s Digital Alarm
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory Application Publications No. All 24393 ACCORD (DX, LX) SYSTEM 2-AND 4-DOOR Issue Date AUG 2002 PARTS LIST Security System Attachment (LX): P/N 08E55-SDA-100A Unit panel
LST-3800. In-Dash Digital Sonar Gauge. Installation & Operation Instructions
Pub. 988-0064-351 LST-3800 In-Dash Digital Sonar Gauge Installation & Operation Instructions The LST-3800 is a depth and temperature gauge that comes with a 200 khz transducer, features deep and shallow
AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810
AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810 This Manual and the information contained therein is the property of AMI Marine (UK) Ltd. It must not be reproduced
Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.
Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
Addendum to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A
PROXIMITY CARD READERS C-10, C-20, C60, C70
Installation Manual PROXIMITY CARD READERS C-10, C-20, C60, C70 VERSION 1.0 CONTENTS 1. General information................................. 3 2. Technical data......................... 4 3. Connection
LUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
To Purchase This Item, Visit BMI Gaming www.bmigaming.com 1-800-746-2255 + 1-561-391-7200. Operation Manual
Operation Manual 90MAN 01 B Copyright 2008 Patent Pending All Rights Reserved Table of Contents Game Play 3 Game Set up 4 Technical Description 5 Programming 6 10 Error Codes 9 Electronic Components 11
2003/2004/2005 TOYOTA COROLLA
2003/2004/2005 TOYOTA COROLLA KEYLESS ENTRY UPGRADE SECURITY SYSTEM INSTALLATION INSTRUCTIONS KIT NO. 00016-30120 SPECIAL NOTE: Installation Sequences After TMS and Safety mandated preparatory steps have
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS
PT-6000 Power Tower INSTALLATION MANUAL 10.5 9.75 12 22.75 10.75 MAXIMUM SOIL HEIGHT: DO NOT ALLOW FILL TO EXCEED THIS LEVEL! 11.5 4 4 13 Optional PT-BASE for new installations or when previous 2000/6000
CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor
CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5
MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL
Centralized On-Off Remote Controller MC-821SC-E [FOR INSTLLER] INSTLLTION MNUL English [ [ π À À π ] E XEIPI IO O H IøN E KT T H [ [MONTÖR Ç N] MONTJ ELK TBI ÏÏËÓÈÎ [ДЛЯ УСТАНОВИТЕЛЯ] РУКОВОДСТВО ПО УСТАНОВКЕ
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
REV 000A. High Quality Nautical Equipment BALDER BLD 600 BLD 900 BLD 1200
REV 000A High Quality Nautical Equipment BALDER BLD 600 BLD 900 BLD 1200 GB User's Manual WINDLASS FOR INSIDE/STERN GB INDEX Pag. 14 Technical data Pag. 15 Installation Pag. 16 Connection diagram 600W
ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive
CoolWave r 2 Phase Control Board and Cable Replacement Kits
Instruction Sheet P/N 1102452A CoolWave r 2 Phase Control Board and Cable Replacement Kits Two kits are available to replace the CoolWave 2 phase control board: S S Phase Control Board and Cable Kit (required
Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE
Wespot SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE EN This manual is published by OPTEX, without any warranty. Improvements and changes to this manual necessitated by typographical errors, inaccuracies
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual
Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com [email protected] TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004
Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical
I STAR COMPUTER CO., LTD
I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON
A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.:
Documento: M-010.1-MGAS-ENG Edizione: 01/1997 Rev.: A.1 a Division of Pittway Corporation FRONT PANEL & VISUAL INDICATIONS GENERAL TROUBLE GENERAL PROGRAMMING IN PROGRESS ENABLE/ALARM/TROUBLE (ZONE 1 ALARM
Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at: 01491 410913 www.theclimate.co.uk
Technical Overview Add-on Sensors - Smoke Alarm Get yours direct at: 01491 410913 www.theclimate.co.uk OVERVIEW This kit contains a standard smoke alarm and relay pattress. The Kidde Smoke Alarm supplied
Transmitter Actuator 230V wave UP 560. Operation
Transmitter ctuator 230V wave UP 560 5WG3 560-201 Product- and pplication Description Diagram The transmitter actuator 230V wave UP 560 (Diagram ) is a flush-mounted device with radio communication for
«Filter-MB» Technical Manual
Technical Manual www.tec-electronics.ru/en/ Unit Description... 2 Unit connection... 2 Table 1. Unit port outputs assignment... 3 Conenction recomendations... 3 Table 2. Technical data and operation conditions...
FT-100 Fire Training Fog Machine User Manual English
FT-100 Fire Training Fog Machine User Manual English 2015 Antari Lighting and Effects Ltd. User Manual - English Safety Information Please read the following safety information carefully before operating
RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES
PART NUMBER: 250-9612 GENERAL APPLICABILITY THIS CRUISE WAS TESTED AND VERIFIED ON: FORD FOCUS SE & S MODELS (AT/MT) FORD TRANSIT ALL MODELS RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory Application Publications No. AII 26327 2004 S2000 Issue Date OCT 2004 PARTS LIST Security System: P/N 08E51-S84-100 Attachment Kit: P/N 08E55-S2A-101 2 Remote controls
INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200
INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200 FUSION CULTURE TABLE OF CONTENTS There s no point doing something if no one notices. We ve always believed the way to make things happen is by getting
BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide
BBWX1 Satellite Weather Receiver Installation and Maintenance Guide Rev FUSA 15JUL2007 Table of Contents Safety Precautions 3 Disclaimer. 3 Contents of Package. 4 Tools Required..4 Installation General
HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.
HID H4 BI-XENON FITTING GUIDE Carefully read the following notes before starting work. WARNING! This HID kit should only be installed by someone competent in vehicle wiring and electrics. Incorrect fitment
Installation & Operation Manual
GET CONNECTED Installation & Operation Manual DEVICE INTEGRATION AND CHARGING KIT TranzIt USB IS32 Note to Readers, The information contained within the following documentation is subject to change without
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054
WIRELESS ALARM KIT COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS Model Number: IT214054 INSTRUCTION MANUAL Warranty Details/Support This product is warranted against defects for a period of One year if the
AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL
ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142
INSTALLATION MANUAL. Installation Instructions
INSTALLATION MANUAL Power-Pole Signature Series Shallow Water Anchor Installation Instructions CAUTION: Read this instruction manual carefully. Become familiar with the controls and know how to operate
PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00
Standalone door control module PK-01 Firmware version 1.00 pk-01_en 06/12 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 [email protected] www.satel.eu WARNINGS Read carefully
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
INSTALLATION GUIDE OWNER S GUIDE
INSTALLATION GUIDE OWNER S GUIDE KEYLESS ENTRY MODELS KE100 / KE150 / 1702 CONTENTS System Features... 1 System Components... 1 Technical Assistance... 1 Before You Begin... 1 Precautions... 1-2 Making
Copyrights 2010 Victron Energy B.V. All Rights Reserved
Manual EN 1 Copyrights 2010 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose. For conditions of use and permission
site monitoring Kit Site Monitoring Kit User Manual we prove it.
site monitoring Kit 1 User Manual Site Monitoring Kit User Manual we prove it. 2 site monitoring Kit Content 1. Introduction 3 2. Content of the Site Monitoring Kit 4 3. Preparation 6 1. Positioning of
Power Window/Power Lock Installation. To begin with you will need all the parts listed below:
Power Window/Power Lock Installation To begin with you will need all the parts listed below: From Donor Fiero: Fiero power window regulators Power window motors (Generic GM type part) -motors are riveted
INSTALLATION AND OPERATION MANUAL
ECO-WORTHY INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL www.eco-worthy.com ECO-WORTHY Solar tracker ECO-WORTHY 400 Solar Tracker Owner s Manual Manual User Installation instructions
SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
AerAtron. Ceiling fans
AerAtron Ceiling fans User Manual & Technical Specifications Models: e502 & e503 Electricians PLEASE FOLLOW THESES INSTRUCTIONS CAREFULLY & PAY SPECIAL ATTENTION TO THE NOTES NOTES WILL ASSIST WITH AN
BL-DBK150A DUAL BATTERY 12v 150 AMP SMART SYSTEM
BL-DBK150A DUAL BATTERY 12v 150 AMP SMART SYSTEM Waterproof and Shockproof Easy DIY Dual Battery System BL-DBK150A Supplied Parts List Parts List 1 x 12v 150Amp Electronic Dual Battery Smart Controller
500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
Traditional Sonar and DSI Sonar Installation
Traditional Sonar and DSI Sonar Installation This document covers the installation of the transducer and display unit installation, which includes connecting the unit to power and installing the unit on
Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage
Description Supports DALI interface driver Programming Supports 0-10V Programmable Driver Programming Supports Other Controllers (TDD-ANPNx, SDD-AAPNx) Off-line programming capability Auto programming
Power Socket (2 Gang)
Version 2.1 Power Socket (2 Gang) Model No. LW270 Instruction Manual Connect Series www.lightwaverf.house EC DECLARATION OF CONFORMITY Responsible Authority: LightwaveRF PLC, Innovation Campus Birmingham
USER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER
ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com
StructureScan HD Transom mount Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Warning: It is your sole responsibility to install and use the instrument and transducer(s)
PRO PLM Installation Instructions
PRO PLM Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components
Operating instructions Switching amplifier for fibre optics. OBF5xx 704876 / 00 08 / 2010
Operating instructions Switching amplifier for fibre optics OBF5xx 70876 / 00 08 / 00 Contents Preliminary note. Symbols used Functions and features. Applications Installation. Attaching the fibre optics
PRO 5000 CPE 1D Quick Installation Guide
PRO 5000 CPE 1D Quick Installation Guide Introduction This Quick Installation Guide covers the basic installation of the PRO 5000 CPE. For more information, refer to the relevant sections in the Product
BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS
BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS WG2 Dimensions: LxHXW: 26 x 14.5 x 29.5 cm INTERNAL Alarm Terminals EXTERNAL Alarm Terminals WG2 Control Unit WaterGuard
bba - Balboa Bluetooth Audio (AMP) Installation & User Guide
bba - Balboa Bluetooth Audio (AMP) Installation & User Guide Bluetooth Integration CONNECT YOUR SMART DEVICE TO YOUR HOT TUB With Bluetooth connection you can now play all your favorite songs directly
Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter
MODEL PRO-9744 INSTALLATION MANUAL Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter This System Allows The Transmitter Buttons To Be
P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System. 2015 Stillwater Designs P150SC15-A2-20150813
P150SC15 Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Subwoofer Assembly Amplifier Assembly Amplifier Harness 2015 Stillwater Designs P150SC15-A2-20150813 M6 Bolt M6
WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING
WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING DESCRIPTION: An electronic control panel used in conjunction with one pulse meter (water meter with pulse output proportional to flow rate)