DVI 980/982 (Honeywell Nr. S4865) Gas Burner Safety Control
|
|
|
- Ashlynn Shelton
- 10 years ago
- Views:
Transcription
1 Gas Burner Safety Control For 1- or 2-stage forced draught and atmospheric gas burners, with DC valves Possible flame detectors: - Ionisation probe - Infrared flicker detector UV flame sensor UVD 971 A Honeywell Company (Honeywell Nr. S4865) EN1C-0121SZ20 R0305 INRODUCION he burner control boxes DVI980/982 controls and supervises forced draught and atmospheric gasburners. hey are approved and certified according to the applicable European standards and regulations. he use on direct air heaters according DIN 4794 is also possible. he microprocessor-based programming sequence ensures extremely stable timings independent of voltage variations, ambient temperature and/or switch-on cycles. he built-in information system not only provides a continuous monitoring of the actual state of the box (very helpful especially for monitoring the start-up phase) but also informs about the cause of a possible lock out. he lock out cause is stored in such a way that it can be retrieved even after a power failure. he control box is designed for maximum safety in case of fluctuations in the voltage supply. If the mains voltage drops below the permitted level, operation is interrupted and the control box automatically prevents the start sequence from being repeated. In this way, the safety of the system is not put at risk by a drop in the mains voltage. his low-voltage protection works not only during start-up but also permanently during operation. CONSRUCION FEAURES Microprocessor, electronic components, output relais, ignition spark generator and flame amplifier are placed on the printed circuit board. hese plus the optional lockout- and reset circuit are well protected inside a flame resistant plastic housing. he LED for displaying the information system are placed on top of the housing. YPES AVAILABLE DVI stage DVI stage MODELS he following functions can be configured by factory: with or without air proving switch volatile or non volatile lock out recycling (numbers eligible) or lock out / blocked after loss-of-flame during operation recycling (numbers eligible) or lock out / blocked without flame establishment after safety time with or without internal reset button potential free output for flame signal with or without lock out lamp (LED) able of timings (sec.) ECHNICAL DAA Operating voltage 220 / 240 V ( %) 50/60 Hz (±5%) Fuse rating 10 A fast, 6 A slow Power consumption ca. 12 VA Max. load per output - term. X2/6 motor 2.0 A, cos ϕ 0.4 Variation A - term. X3,X5, X6 solenoid valves 90mA, DC Variation B - term. X3, X9, X5, X6 solenoid valves 90mA, DC only DC-valves can be connected! - term. X2/8 lock out 1.0 A, cos ϕ 0.4 total load max. 6 A during 0,5 sec Air proving switch 1 working contact SB Safety temperature delimiter 1 working contact Ignition spark generator Ignition frequency up to 40 Hz Energy ignition spark 10 µas Ignition voltage 20 kv Sensitivity (operation) 1 µa Min. required ion. current 1.5 µa Sensitivity for stray light 0.4µA Flame signal output Optocoupler max 70V DC/100mA Ionisation probe insulation Probe - earth greater than 50 MΩ Stray capacity Probe - earth less than 1000 pf Cable length < 3 m Flame detectors IRD end-on viewing UVD 971 end-on viewing Weight incl. Wiring base 190 g Mounting position any Protection class IP 40 Approved ambient parameter - for operation -20 C C - for storage -20 C C Build-up of ice, penetration of water and condensing water are inadmissible Approvals according to European standard EN 298, as well as all other relevant Directives and standards Model max. reaction time or supervised pre-ignition ignition time stray light safety time delay 2nd stage air proving switch pre-purge time time total monitoring (DVI 982) tlw tv1 tvz tz tf ts tv
2 APPLICAION FEAURES 1. Information system he information system is microprocessor based and reports on all aspects of burner control box operation and flame supervision. It informs continuously about the actual programming sequence the unit is just performing. Besides monitoring of the programming sequence it also allows to identify errors during start-up of operation without any additional testing devices. he automatically performed diagnosis is a valuable tool which facilitates service/ maintenance work and therefore saves costs. he analyses of the error cause can be done directly on stage or if not possible afterwards as the lock out reason is stored in a non-volatile lock out mode memory. he information system communicates with the outside world using a LED (the used Flash-Code is similar to the Morse-Code). he messages are optically transmitted by a appropriately flashing LED. Using an additional terminal (optional), the messages can be recorded and displayed in easy readable form. 1.1 Programming sequence display he built-in microprocessor controls not only the programming sequence but the information system too. he individual phases of the programming sequence are displayed as Flash-Code. he following messages can be distinguished: Message Flash-Code waiting for. air proving switch pre-purge. tv1 pre-ignition. tvz safety time. ts delay 2nd stage. tv2 running _ 1.2 Lock-out diagnoses In case of a failure the LED is permanently illuminated. Every 10 seconds the illumination is interrupted by a flash code, which indicates the cause of the error. herefore the following sequence is performed which is repeated as long as the unit is not reset. Sequence: illuminated phase dark phase Flash-Code dark phase for 10 sec for 0.6 sec for 1.2 sec Error diagnosis: Error message Flash-Code Possible fault lock out within safety time safety time no flame establishment stray light stray light during monitored phase, detector may be faulty air proving switch air proving switch in closed position contact welded air proving switch air proving switch does not time-out close within specified time air proving switch air proving switch opens opened during start or operation loss of flame loss of flame signal during operation Flash-Code for manual lock out manual/external lock out (see also 3. lock out and reset) Error R or SB opens Safety temperature delimiter SB opens. For reset, the supply line must, for a short time, be interrupted after pushing the reset button. low mains voltage Internal fuse defect > control box defect Description = short pulse = long pulse. = short pause _ = long pause _ _ 2. Flame detection he following types of flame detectors are suitable: Ionisation probe, temperature resistant material, well insulated (material and insulation same as for ignition electrode). Infrared-flicker detector type IRD with mounting flange M 93 or the UV solid state flame sensor UVD 971. Flame detection using an ionisation probe is only possible in conjunction with mains supplies which provides a neutral earth connection. Connecting the IRD or UVD 971 the correct wiring has to be observed. 2.1 Stray light monitoring he stray light check is performed at the end of the prepurge time for the duration as mentioned in the table of timings. 2
3 3. Lock out and reset he unit can be reset or brought into lock out mode in two different ways: Internal (optional) In the lock out case the unit can be reset by pushing the reset button meaning a new start-up cycle is performed. External Instead of using the reset lock out button the same function can be achieved by using an external button which connects terminal X2/12 with X2/9 (see also circuit and block diagram). Models with volatile lock out also can be reset by a shorttime interrupt of the supply line. If the pushbutton (internal or external) is pressed during normal operation or during the start sequence for more then 3 sec. and afterwards released, the control box will perform a shutdown. Please note he unit can only be brought to lockout mode or be reseted if power is applied to the unit. Don't apply to units with volatile lock out. 4. Low-voltage protection he mains voltage has to be more than 193 V eff in order to allow the unit to perform a start-up. he mains voltage is not only monitored in the start-up phase but also permanently during operation. If the voltage drops below < 175 V eff during start-up or run time the control box proceed to safety shut-down and goes into a waiting status. If the voltage rises again, the control box performs automatically a start-up as soon as the mains voltage is > 193 V eff. 5. Safety he design and control sequence of the DVI980/982 controls will comply with the currently applicable standards and regulations (see also ECHNICAL DAA). 6. Mounting and electrical wiring he is put directly on the solenoid valve. Molex plug connector 3003 for: Power supply line Control thermostat R Air proving switch LW Motor M External lock out signal Safety temperature delimiter SB External reset and lock out button Counterpart: Molex plug connector 3001 General he control box and the sensor shall not be exposed to excessive vibrations. 7. Model functions he following functions are configured by factory Model 01: with air proving switch non volatile lock out, no reset with interrupt of the supply line direct lockout after loss of flame during operation direct lockout if no flame established after safety time with internal reset button without potential free output for flame signal Circuit diagram: "valve supply over air proving switch contact", variation A, see page 5) Model 02: with air proving switch non volatile lock out, no reset with interrupt of the supply line altogether 2 times recycling if no flame established after safety time or loss of flame during operation without internal reset button potential free output for flame signal Circuit diagram: "valve supply not over air proving switch contact", variation A, see page 5) with internal lock out lamp (LED) Model 05: with air proving switch volatile lock out, reset with interrupt of the supply line altogether 2 times recycling if no flame established after safety time or loss of flame during operation without internal reset button potential free output for flame signal Circuit diagram: "valve supply over air proving switch contact", variation A, see page 5) with internal lock out lamp (LED) 3
4 INSALLAION INSRUCIONS AND MAINENANCE 1. Important notes he controls must be installed by qualified personnel only. he relevant national regulations have to be observed. On commissioning the wiring has to be carefully checked according the appropriate diagram, Incorrect wiring can damage the unit and endanger the installation. he fuse rating has to ensure that the limits specified in ECHNICAL DAA will not be exceeded. If these precautions are not observed, the effect of a short circuit can cause severe damage to the control and installation. For safety reasons a minimum of one control shutdown per 24 hours has to be observed. Disconnect the mains before the control box is plugged in or out. he control box is a safety device and must not be opened! 2. Function control For safety reasons the flame detection system should be tested on commissioning the installation as well as after a service or longer shut-down. a) Start-up with closed gas valve for direct lockout operation, after safety time is over the unit has to go into lock out mode! for recycling operation (max. recycling limited) carry out a re start-up. b) Normal start-up, when burner is running, close gas valve for direct lockout operation, after loss of flame the control box has to go into lockout mode! for recycling operation (max. recycling limited) carry out a re start-up. c) Normal start-up, during pre-purge or operation, interrupt the air proving switch for direct lockout operation, the control box has to go into lockout mode immediately! for recycling operation (max. recycling limited) carry out a re start-up. 3. Fault finding he built-in information system facilitates the trouble shooting in the case of problems occurring during start-up or during operation. A list of possible lock out messages can be found in APPLICAION FEAURES chapter 1.2. Please note: he control box is locked in lock out mode and the reason for the lock out is displayed until the control box is reset, either by an internal or external reset (see also subject 3. Lock out and reset ). Interrupting the supply line (by models with non volatile lock out) may not reset a lock out. herefore, by applying power, the fan motor switches on for 2-3 secs. before the control box goes to lock out again in cause of the last lock out. Error Possible fault Burner not working - hermostat circuit open - Faulty electrical wiring - Mains voltage < 193 V Fan motor starts for a short - Control box has not been reset period of time, control box - Air proving switch not in open goes to lock out position Control box locks out or - Air proving switch has not closed recycled during pre-purge within 60 sec. - Air proving switch has re-opened Control box locks out or - Air proving switch open recycled at the end - Flame signal (stray light) of pre-purge Burner starts, - No ignition or no gas flame not established, after safety time lock out or recycling Burner starts, - No or to low flame signal (flame flame established, does not stick, bad insulation of after safety time the ionisation probe, bad conneclock out or recycling tion to frame ground) - Insufficient light on IRD or UVD - Sensitivity adjustment to low on IRD d) Bridged air proving switch before start the fan motor switches on for approx. 2-3 sec., followed by a lockout. After 10 sec., this quick lockout is resetted by the control box and a second start attempt follows (fan motor switches on for approx. 2-3 sec.). A standard lockout appears if the air proving switch (LW) contact is still in it s closed position (e.g. welded contacts). Has the air proving switch (LW) changed to it s open position in the meantime (e.g. by a run down motor), a normal start sequence follows. DVI 982/982 4
5 CIRCUI AND IMING DIAGRAM Using only the connection diagram for the wiring which is noted down for the respective model variation (see "7. model functions", page 3). A wrong wiring leads to malfunctions! Valve supply not over air proving switch contact Ph max. 10A fast 6A slow HS EV X X7 X8 X3 X9 X5 X6 LW P R SB Z IS M SA N variation A variation B tlw tv1 tvz tz ts tv2 Without air proving switch Ph N max. 10A fast 6A slow HS M R EV X X7 X8 X3 X9 X5 X6 SB SA Z IS variation A variation B tv1 tvz tz ts tv2 Valve supply over air proving switch contact Ph max. 10A fast 6A slow HS EV X X7 X8 X3 X9 X5 X6 P LW R variation A SB M SA Z IS variation B N tlw tv1 tvz tz ts tv2 IRD- OR UVD CONNECION IRD UVD 971 blue black brown Kl. X2/11 Kl. X8 Kl. X2/12 HS Mains switch EV External reset and lock out button R Control thermostat LW Air proving switch SB Safety temperature delimiter Using wire link for application without SB. M Motor SA External lock out signal IS Ionisation probe (IRD , UVD 971 see separate diagram) Z tlw tv1 tvz tz ts tv2 Ignition probe Solenoid valve 1st-stage Solenoid valve 2nd-stage Max. reaction time for air proving switch Supervised pre-purge time Pre-ignition time Ignition time total Safety time Delay 2nd-stage 5
6 BLOCK DIAGRAM DIMENSION Oscillator EEPROM lock out lamp (LED) Information system 60 µc Watchdog Reset and lock out Reset µc Mains monitoring X8 Flame amplifier Power supply monitoring Flame signal output R R RS Power supply X7 Ignition spark generator rs rv1 + valve supply X3 X9 X5 X6 230V DC 230V DC UVD 971 IRD HOLDER M 93 FOR IRD UVD = 29 IRD = X2 Variante A 230V DC Variante B 230V DC 230V DC Note: Equipment for connection version A is fitted differently to version B. > no exchange possible! 21,8 21,8 ø13,5 UVD = 89 IRD = 104 ø20.5 ORDERING INFORMAION IEM DESIGNAION IME NO. Control box DVI 980 Mod Control box DVI 980 Mod Flame detector IRD D end-on or UVD Holder IRD Holder M 93 for IRD Holder UVD Holder M 74 for UVD Connection cable Plug-type, 3-core cable, 0.6 m with tag wire end he above ordering information refers to the standard version. Special versions are also included in our product range. Specifications subject to change without notice 6 A Honeywell Company Satronic AG Honeywell-Platz 1 Postfach 324 CH-8157 Dielsdorf
DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners
A Honeywell Company Gas Burner Safety Control For 2-stage forced draught and combi oil/gas burners Possible flame detectors: - Ionisation probe - Infrared flicker detector 1020 - UV flame sensor UVD 971
DKG 972 Gas Burner Safety Control
A Honeywell Company Gas Burner Safety Control For 2-stage atmospheric gas burners Flame detection: - Ionisation probe - Infrared-flicker detector IRD 1020.1 - UV flame sensor UVD 971 EN1C-0127SZ20 R0305
TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. 2 Inch PowerVent LED Indicator Explanations & Troubleshooting Table
New Robertshaw control valve was introduced in May 2008 as a replacement part. See last page for troubleshooting this replacement part. All voltage inputs are 120V. All electrical connectors are Molex
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html APPLY POWER TO APPLIANCE FIELD WIRING CORRECT? DPLAY ERROR CODE 1 OR 2 Intelli-Vent TM Sequence of Operation REQUEST FOR HEAT PRESENT?
1 QPro HelpFile 01.EN.2010 2010 COPYRIGHT CONTRIVE
QPro is a free software tool for Burner Management Systems made using Quad and TraxBus TM. Using QPro it s possible to upload and download configuration parameters for the following devices: Quad Quad400
FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html TECHNICAL SERVICE DEPARTMENT Effective October 2007, we transitioned to the White Rodgers (Intelli-Vent TM )Thermostat Control for
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
Manual MPA 41xx. Edition: 02.14. Nr. 257 454 - GB. Printed in Germany Edition 02.14 Nr. 257 454
Manual MPA 41xx Edition: 02.14 GB 1 126 Nr. 257 454 - GB Table of contents Data sheet...3-6 Approval Overview...7 System description/variants/accessories/approvals...8 General technical data...9 Connection
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
ONE STAGE GAS BURNERS RIELLO 40 FS SERIES FS3 11 35 kw FS5 23 58 kw FS8 46 93 kw FS10 42 116 kw FS20 81 220 kw
ONE STAGE GAS BURNERS RIELLO FS SERIES FS3 35 kw FS5 3 5 kw FS 93 kw FS kw FS kw The Riello FS series of one stage gas burners, is a complete range of products developed to respond to any request for light
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
AUTODIALLER / QUICKDIALLER - SA132
AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING
Conventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
i ChatterBox! Motorcycle Security
i Before you Start the Installation * Please read this manual to become familiar with the requirements necessary to complete the installation. * Use a high quality multi-meter to test all wires before
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
TWO STAGE GAS BURNERS RIELLO 40 GSD SERIES GS10D 29/41 106 kw GS20D 58/81 220 kw
TWO STAGE GAS BURNERS RIELLO 4 GSD SERIES 9/4 6 58/8 The Riello 4 GSD series of two stage gas burners, is a complete range of products developed to respond to any request for home heating. The Riello 4
Technical Information
Date of last update: Oct-11 Ref: D7.8.4/1011/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS CoreSense Diagnostics for Stream Refrigeration Compressors... 1
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
Inwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
Thermo Top - Troubleshooting Tree
Thermo Top - Troubleshooting Tree 07-15-2002 CAUTION Troubleshooting requires comprehensive knowledge about the structure and theory of operation of the Thermo Top heater. Troubleshooting and repairs may
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
How To Control A Car Alarm On A Car With A Remote Control System
MODEL CA100 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM Black Antenna Wire 6 Pin 6 Pin Mini Connector Valet Switch Blue LED Indicator Blue Wire: (-) 200mA Unlock
B/S/H/ Error codes and service programmes PH
1 ERROR CODES AND APPLIANCE MESSAGES... 3 1.1 Complete overview of all error codes (in order)... 3 Automatic switch-off... 3 Display is dark and any individual LEDs are lit... 3 E 005... 3 E 011... 3 E
VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)
FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Model 7586. Description / Applications. Intermittent Pilot Gas Ignition Control
PARTS & ACCESSORIES Model 7586 Intermittent Pilot Gas Ignition Control Description / Applications The Beckett GeniSys Intermittent Pilot Gas Ignition Control is a 24 Vac gas ignition and safety control.
Option field bus: without bus with profibus DP. Design-Index (Subject to change)
Amplifier / controller cards ED1 Digital amplifier / controller card ED1 for 1 or 2 proportional solenoids 4 analogue inputs, of which 2 for differential inputs 8 digital inputs Card setting via PC, multi-function
Mureva Assembly surface mounted wiring devices
1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL
ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 12/6/10 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1-2 SERVICING TIPS AND INSTRUCTIONS Page 3-4
TT 49 MICROPROCESSOR-BASED DIGITAL ELECTRONIC TIMER. OPERATING INSTRUCTIONS Vr. 01 (ENG) - cod.: ISTR 06050. TECNOLOGIC S.p.A.
TT 49 MICROPROCESSOR-BASED DIGITAL ELECTRONIC TIMER INDEX..2 2 2. 2.2 2.3 3 3. 3.2 3.3 3.4 4 4. 4.2 4.3 4.4 4.5 5 5. 5.2 6 6. 6.2 7 7. 7.2 7.3 7.4 7.5 INSTRUMENT DESCRIPTION GENERAL DESCRIPTION FRONT PANEL
Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10
ABB ABB Schweiz AG Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205 09.04.2014 Page: 8201 Schaffhausen 1 / 10 Please use also the assembly instruction S800-RSU-H Remote
MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA
w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES
USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES 204.CAxxx 204.CBxxx 204.UBxxx 204.WBxxx MP36289 1 ZP90856-GB-6 INDICE 1 SYSTEM DESCRIPTION... 4 1.1 MODES OF OPERATION... 4 2 USER INTERFACE... 6 2.1
Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ-100 08E55-SHJ-100. 2004 American Honda Motor Co., Inc. - All Rights Reserved.
Kit No. 08E5-SHJ-00 08E55-SHJ-00 Security System Owner s Manual ODYSSEY 004 American Honda Motor Co., Inc. - All Rights Reserved. Contents Introduction... 3 Emergency Disarming During the Panic Alarm Activation...
Product Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: [email protected] Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
13 SERIES. Electronic step relays 10-16 A 13.81 13.91
13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function
Operating instructions Optical distance sensor O1D100 O1D103 704991 / 00 08 / 2012
Operating instructions Optical distance sensor UK O1D100 O1D103 704991 / 00 08 / 2012 Contents 1 Preliminary note4 1.1 Symbols used 4 1.2 Warning signs used 4 2 Safety instructions 4 3 Functions and features
Adjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
ABS Flash Code (Blink Code) Instructions
ABS Flash Code (Blink Code) Instructions Innovative Products of America Incorporated Tinker Street, Woodsttock, NY 8 Local: 8-6-00 Toll Free: 888-86-8 Fax: 8-6-600 www.ipatools.com [email protected] ABS
LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems
Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will
I D F GB E NL 3755116 GS3 551T1 3755117 GS3 551T1
Istruzioni per installazione, uso e manutenzione Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Instrucciones para la instalación, uso y mantenimiento
MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
...een product van BEKA
Integrated electric controller S-EP with Hirschmann connector Contents Page EP- pump with integrated controller S-EP Algemeen. Functional features. Time control -. Stroke control Supplementary functions.
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
Fossil fuel heating equipment
Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating
FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5
F ballasts T PCA T EXCE oneall lp Y, x1/ W and x1/ W EXCE T Product description Processor-controlled ballast with y inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions
DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable
S4560 AUTOMATIC IGNITION CONTROL APPLICATION SPECIFICATIONS
S4560 AUTOMATIC IGITIO COTRO Subject to change without notice. rinted in the etherlands. AICATIO The S4560 provides automatic ignition and control for burners in accordance with E 298. SECIFICATIOS Model
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim
Automotive sensor simulator Operating manual AutoSim Contents Introduction.. page 3 Technical specifications.... page 4 Typical application of AutoSim simulator..... page 4 Device appearance... page 5
Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual
Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Application Engineering
Application Engineering February 2011 Electronic Unit Controller Table of Contents 1. Introduction and Features... 2 1.1 Technical Specifi cations... 3 1.2 Pressure Probe Error Bypass... 3 1.3 Bump Start...
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
Operating instructions Switching amplifier for fibre optics. OBF5xx 704876 / 00 08 / 2010
Operating instructions Switching amplifier for fibre optics OBF5xx 70876 / 00 08 / 00 Contents Preliminary note. Symbols used Functions and features. Applications Installation. Attaching the fibre optics
Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
FL ballasts Electronic dimming. PCA T5 ECO lp Y II, 14 80 W ECO T5
EL PCA ECO lp Y II, 1 80 W ECO Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DALI or DSI signal, switchdim
INSTRUMENT PANEL. 1995 Volvo 850 DESCRIPTION & OPERATION. 1995-96 ACCESSORIES & EQUIPMENT Volvo Instrument Panels
INSTRUMENT PANEL 1995 Volvo 850 1995-96 ACCESSORIES & EQUIPMENT Volvo Instrument Panels 850 WARNING: When working around steering column and before performing repairs, disconnect and shield battery ground
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
COMPALARM AP GENERAL MAIN FEATURES
GENERAL The COMPALARM AP is a point alarm system, with as many normally closed input contacts. It givesthe possibility of selecting the alarm sequence according with 0 x 0 mm cells, fitted with ultra bright
Fire Alarm Control Panel. Family. Operating Manual
Fire Alarm Control Panel Family Operating Manual CONTENTS System Description AH-03312 System Characteristics... Fire Signal Receiving Board Description-4L... Fire Signal Receiving Board Description-8L...
ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
GeniSys 12V. Model 7556. Description / Applications. Advanced 12 Vdc Burner Control
PARTS & ACCESSORIES GeniSys 12V Model 7556 Advanced 12 Vdc Burner Control Description / Applications The Beckett GeniSys TM 12V Advanced Burner Control is a 12 Vdc primary safety control for oil burners
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
PNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
basicdim DGC Compact control module
luxctrol lighting control sstem DGC Compact control module Product description Compact dimensions for luminaire installation For up to 0 DSI or LI ballasts ( per output channel) LI IN input LI/DSI output
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, 14 80 W EXCEL T5
E T5 TC- PCA T5 EXCE oneall lp Y II, 1 80 W EXCE T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via I or
Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual
Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com [email protected] TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION
Operation Manual for Users
Operation Manual for Users Model No.: FLTAMFMRCD!!!!!!!!!! ATTENTION!!!!!!!!!! THE RESET BUTTON MUST BE PRESSED TO ENSURE PROPER OPERATION. SEE INSTRUCTION MANUAL Table of Contents Table of Contents ---------------------------------------------------------------------------------------------
Electronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
