White Paper 5 PILLARS OF A WORLD-CLASS DATA CENTER



Similar documents
White Paper THE TRUTH ABOUT DUAL POWER FEEDS

AT&T Internet Data Center Site Specification - Phoenix Area (Mesa, AZ)

Experience Matters...

AT&T Internet Data Center Site Specification San Diego Koll (San Diego, CA)

san francisco//usa data center specifications tel: fax: internet + intellectual property + intelligence

LEVEL 3 DATA CENTER SERVICES IN OMAHA, NEBRASKA HIGH AVAILABILITY ENTERPRISE COMPUTING BUSINESS DEMANDS IT. LEVEL 3 DELIVERS IT.

N O W A V A I L A B L E

AT&T Internet Data Center Site Specification Washington-DC Area (Ashburn, VA)

19 Site Location, Design and Attributes. Site Location, Design and Attributes

AT&T Internet Data Center Site Specification Chicago Area (Lisle, IL)

How To Visit An Internet Data Center

Scalable. Affordable. Flexible. Fast.

Data Center Infrastructure & Managed Services Outline

NORTHERN VIRGINIA ONE (NoVa) DATA CENTER OVERVIEW

CHICAGO S PREMIERE DATA CENTER

About Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

Matthias Machowinski, Directing Analyst for Enterprise Networks and Video, Infonetics Research, 20152

7QUESTIONSYOUNEEDTOASKBEFORE CHOOSINGACOLOCATIONFACILITY FORYOURBUSINESS

OPERATOR - FACILITY ADDRESS - DATE

Powering the Cloud Desktop: OS33 Data Centers

AT&T Internet Data Center Site Specification New York III (Secaucus, NJ)

SolveXia Business Continuity Planning

100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

Data Center Checklist

Overcoming the Causes of Data Center Outages

Enabling an agile Data Centre in a (Fr)agile market

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

SLA. Co-Managed. Do-It-Yourself

AT&T Internet Data Center Site Specification Dallas Area (Allen, Tx)

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group

Data Center Commissioning: What you need to know

Data Centre Barrie, Ontario

Location. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport

Colocation, Hot Seat Services, Disaster Recovery Services, Secure and Controlled Environment

Data Center Energy Profiler Questions Checklist

Data Centre Basiglio, Milan Flexible, advanced and efficient by design.

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

X-tier Data Facility. Prepared by X-tier SAE Corporation

LEVEL 3 DATA CENTER SERVICES IN SAN FRANCISCO HOUSE POWER-INTENSIVE APPLICATIONS AND SUPPORT BUSINESS CONTINUITY

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Data Center Trend: Distributed Power in the White Space

Thermal Storage System Provides Emergency Data Center Cooling

Assessment of Existing Data Centers for Critical Facilities Round Table Group

World-Class Data Centers, Colocation, Cloud & Management Services. Central and Southern Oregon Locations East and West of the Cascade Divide

Department of Administration DATA CENTER Two Phase Approach Located at the State Defense Building

DATA CENTRES UNDERSTANDING THE ISSUES TECHNICAL ARTICLE

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

7 Best Practices for Buying Colocation:

EVALUATING DATA CENTER AND COLOCATION HIGH-AVAILABILITY SERVICE DELIVERY. A FORTRUST White Paper. March,

SYSTRUST CERTIFICATION REPORT FOR COLLOCATION AND DATA CENTER HOSTING SERVICES FOR THE PERIOD FROM JANUARY 1, 2013 TO DECEMBER 31, 2013

High-performance. High-density. Highly committed.

Rittal Liquid Cooling Series

COLOCATION PROVIDERS:

Managing Data Centre Heat Issues

ISOMEDIA COLOCATION

High-performance. High-density. Highly committed. Built for tomorrow. Ready today.

Subject: County of Los Angeles Data Center Space Requirement

Data Centre Infrastructure

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria

in other campus buildings and at remote campus locations. This outage would include Internet access at the main campus.

How To Build A Data Center For Ragingwire

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers

Best Practices for Wire-free Environmental Monitoring in the Data Center

Data Center Management

Data Center Solutions

DataCenter.BZ. Background. Case Summary. & dark fiber solutions

SOC 3 SYSTRUST FOR SERVICE ORGANIZATIONS REPORT

vcloud SERVICE Virtual Tech in partnership with Equinix - vcloud Service

NY2 21 CRITICAL MEGAWATTS 280,000 SQUARE FEET

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

Power and Cooling for Ultra-High Density Racks and Blade Servers

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

Agility Logistics Datacenter Trends in Enterprises. Ben N. Hasnai VP IT Infrastructure and Operations

NeuStar Ultra Services Physical Security Overview

Data Centre Southeast AMS 5, Netherlands Highly connected, premium data centre.

Brought to you by. Colocation Solutions BROUGHT TO YOU BY.

Datacenter Hosting and Cloud Computing Services

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

South Asia s First Uptime Institute Certified TIER-IV IDC in Mumbai delivering % guaranteed uptime

Data Center Equipment Power Trends

Enterprise Data Centres

Best Practices for Wire-free Environmental Monitoring in the Data Center

Oxford Networks Building & Location Attributes Products Security DATA CENTER Bandwidth

A Colocation Buyer s Guide:A What You Should Know Before Making a Colocation Decision

How to Obtain the Uptime, Security and Robust Connectivity Financial Services Firms

Datacentre London 1. Dedicated managed environment for mission critical services. Six Degrees Group

RAGINGWIRE. THE WORLD S MOST TECHNOLOGICALLY ADVANCED DATA CENTERS!

Interconnection for Financial Services

CYRUSONE COMPANY OVERVIEW BUILT FOR TOMORROW. READY TODAY.

IBM Twin Data Center Complex Ehningen Peter John IBM BS 2011 IBM Corporation

disaster recovery - the importance of having a plan

COMMODITIZING THE DATA CENTER MARKET

SWAP EXECUTION FACILITY OPERATIONAL CAPABILITY TECHNOLOGY QUESTIONNAIRE

Raised Floor Data Centers Prepared for the Future

Data Center Solutions - The Containerized Evolution

Relative Sensitivity based Fire Detection Systems used in High Density Computer Rooms with In-Row Air Conditioning Units

Transcription:

Table Of Contents Introduction... p.3 #1: A Purpose-Built Facility... p.3 #2: Robust Utility and Facility Infrastructure... p.5 #3: Cooling High Density Computing Capable... p.7 #4: Best-in-Class Equipment... p.8 #5: The Human Factor... p.9 World-class Data Centers: The Competitive Edge... p.11 About Data Foundry... p.11 About Texas1 Data Center... p.11 2

Introduction A WCDC is designed to be Business Mission Responsive. For colocation this means it s designed to accommodate a wide variety of customer-specific business requirements, and able to adapt to customer business strategy changes as well as growth over time. Michael Mosman, CTO, CCG Facilities Integration As an IT leader, you know the importance of being able to meet your organization s increasing expectations for uptime, scalability and security. Your data center represents a critical piece of the solution. Done right, a data center gives your organization a competitive advantage with uninterrupted, problem-free operations and the flexibility to accommodate evolving business requirements and growth. But not all data centers are created equal. This paper defines the five fundamental characteristics of a true world-class data center (WCDC) one that offers your organization the highest attainable level of reliability, flexibility, scalability and security. A WCDC provides the best operational experience and highest confidence, with the lowest risk of problems that could compromise operations or data in even the most extreme circumstances. The five pillars of a world-class data center: 1. A Purpose-Built Facility 2. Robust Utility and Facility Infrastructure 3. High Performance Computing Capable 4. Best-in-Class Equipment 5. The Human Factor #1: A Purpose-Built Facility Many data centers are retrofitted facilities frequently old warehouses or other large, open buildings that have been converted into a data center. Such buildings cannot deliver the benefits and performance of a purpose-built WCDC. SEATTLE EARTHQUAKES (MODERATE RISK) BOSTON EARTHQUAKES (HIGH RISK) CHICAGO NEW YORK FLOODS SAN FRANCISCO SANTA CLARA TORNADO ALLEY 2 ASHBURN LAS VEGAS HURRICANES LOS ANGELES TORNADOES PHOENIX DALLAS ATLANTA TSUNAMIS AUSTIN HOUSTON U.S. Natural Disaster Map MIAMI 3

Resilience from Disasters A data center should, of course, be located in an area with a low incidence of natural disasters, including strong winds, tornadoes, hurricanes, lightning strikes, flooding and earthquakes. More importantly, a data center should be constructed to withstand disasters, even if the chances are remote that they will occur. Purpose-built data centers are designed to higher construction and performance specifications that make them capable of withstanding extreme weather conditions. For example, high winds from tornadoes or hurricanes present a serious risk to data centers. Many retrofitted buildings are constructed to withstand 90 mph winds, but in a tornado or hurricane winds can reach 160 mph. Protecting against winds of that speed requires a larger investment for higher-grade building materials and construction techniques, including: To provide adequate roof support and to harden against wind-blown projectiles, cinder block or concrete exterior walls should be at least 10 thick, instead of the more common 7 thickness. Instead of a flat concrete foundation, pier footings should secure the foundation deep into bedrock. To provide the necessary weight and strength to prevent lift, the roof should be made of 6 thick concrete, not metal or other fabricated 1 roof materials. In addition, minimal equipment should be attached on the roof, and there should not be any skylights. Exterior doors must be no taller than 7 to attain a wind rating of 160 mph. All structural components from the roof down to the below-ground piers should be welded together to create a rigid integrated structure. A WCDC is hardened to prevent wind-blown projectiles from penetrating any part of the building s shell. If allowed to penetrate, the wind could create very unstable wind pressure within the building, which can lead to catastrophic roof failure. You can achieve these higher design specifications in a purpose-built facility. Mark Merryman, VP/Principal, Haynes Whaley Associates Structural Specs World-Class Data Center Retro-fitted Data Center Wall Thickness 10 7 Roof Thickness 6.5 1 Wind Rating 160 MPH 90 MPH Roof Penetrations Virtually None Excessive - skylights, drains, AC units, etc. PVR (Potential Vertical Rise).75 2 Walls Factory produced Constructed on site Depressed Slab 3 0 Underground Conduit Extensive None Comparison of WCDC design specifications to typical retrofitted facilities. 4

Protecting Utility and Mechanical Equipment In a WCDC, all electrical and mechanical assets are situated where they are the most secure and easiest to maintain. This includes running electrical and telecom conduits underground where they are best protected, and placing generators and transformers indoors where they are protected from weather and can be serviced more efficiently. These options are often not available when retrofitting a building. Housing the generator equipment inside the facility is a superior solution. It s more efficient and better protected from weather and intrusion. And it s much more accessible to maintenance staff. Doug Clough, Regional Office Director, Holder Construction Company Space Utilization Finally, a WCDC allows all space to be configured for maximum efficiency for customers and service technicians. By planning rooms around efficient rectangles from the outset, a WCDC makes it more logical and convenient for customers and staff to navigate and use the data center. In contrast, when reconfigured for data center operations, retrofitted buildings often end up with poorly planned floor space and odd-shaped rooms. #2: Robust Utility and Facility Infrastructure Electricity, network connectivity and water are the lifeblood of a data center. In a WCDC, all utilities are fully redundant and no component or system has a single point of failure. The general strategies for protecting vital infrastructure are redundancy and diversity (physical separation). A WCDC should have dual electrical and water feeds from diverse locations and distribution sources. This ensures that electrical and water supplies are available even if one source is interrupted due to either natural events or human errors. Telecom entry points should also be diverse, ideally on opposite sides of the building for the best security and protection. Dual network, power and water conduits follow diverse paths into facility. 5

Power Multiple levels of redundancy are built into every level of a WCDC s power infrastructure, from the substations to power distribution units. Redundancy starts with dual power feeds supplied by separate substations, with each substation powered by independent power plants. This provides the best alternative power source in case of a major power outage. Underground power feed lines provide added protection from accidental or natural breaks. The redundant power feeds should enter the property and the facility via diverse paths. Many data centers offer redundant power and water feeds. However, some data centers still create a single point of failure by having, for instance, dual power feeds that go to a single transformer, or utilizing non-diverse paths through the property. WCDCs have redundant feeds into the buildings to minimize the chance that a disruption to one feed would affect the other. Kelly Bell, Senior Associate, Bury+Partners Inside the facility, a WCDC is optimally powered by both feeds sharing the load on separate power trains. Should one power source be disrupted, the entire system can quickly switch to power from the single source without any disruption or degradation to operations. Full redundancy also allows any part of the system to be taken offline for maintenance. MV-1 MV-2 MV-1 MV-2 A B A B A B A B A B A B UPS-R UPS-1 UPS-2 UPS-3 UPS-4 UPS-5 A B A B A B A B A B A B UPS-R UPS-1 UPS-2 UPS-3 UPS-4 UPS-5 Dual power feeds with each A-B half POWER of facility FEEDS powered off of alternate utility feed. In case of severe power interruption A-B POWER from FEEDSone source, load is quickly migrated to remaining active feed. A WCDC facility has: Transformers located inside the data center for improved serviceability and security. UPS rooms with two incoming power feeds that deliver true A/B power to servers. A UPS-protected maintenance bypass bus that enables maintenance of UPS systems without exposing equipment directly to utility power. All power distribution equipment located in service galleries to isolate maintenance activities from customers equipment and improve power delivery to cabinets. 6 Water A continuous water supply for chilled water cooling is vital to a WCDC. Like the other utilities, the dual water feeds should enter the property and connect to mechanical equipment through diverse paths. Parallel water lines connect the cooling towers and chillers, providing increased redundancy and concurrent maintainability.

Network Connectivity A WCDC makes it easy for telecom carriers to connect to the facility. Carriers are provided access to underground, concrete-encased duct banks that enter the property and the building via diverse paths. These protected duct banks provide for ample growth of future network providers without the need to dig additional trenches. All of the telecom feeds are delivered to separate carrier rooms inside the facility for full redundancy. It is important to have options when selecting a network carrier. A WCDC is carrier-neutral, where customers can choose their preferred carrier from a long list. Data centers that offer at least 10 carrier options ensure that customers will get the best connectivity for their needs at the most competitive prices. #3: High Performance Computing Capable Managing heat is a primary challenge in every data center. High Performance Computing (HPC) environments produce significantly more heat due to the increased concentration of power to various locations across the floor. To support a wide mix of cabinet power densities, the cooling infrastructure must conserve energy, withstand load increases, and provide consistent, reliable high performance. The cooling system of a WCDC is designed for both reliability and efficiency in real-world conditions. It must operate at maximum efficiency at all load levels regardless of changing external conditions. Not all systems do that. Roy Hubbard, Senior Marketing Manager, Johnson Controls A WCDC effectively manages HPC environments through a chilled water-cooling system. These systems circulate water to any location on the floor that requires cooling, while consuming significantly less electricity than conventional air-cooled systems. This design efficiently cools HPC environments because it supports higher return hot air temperatures and provides higher concentrations of cooling to locations with high-performance equipment. To remove heat, the key is to prevent hot and cold air from mixing, with the hot air efficiently removed from the immediate area. This starts with a raised A chilled water cooling system more efficiently supports HPC environments floor that supports hot and cold aisle cabinet configurations. Cool air is directed under the raised floor to the front cabinet areas and tuned for each area s needs through the configuration of perforated floor tiles or grates on the cool air aisle. The more difficult challenge is removing the hot air from the back hot air aisle of the cabinet area. WCDCs have ceiling return air plenums to quickly segregate hot air and to support air management features such as cabinet chimneys and hot aisle containment partitions, which limit hot air from co-mingling with the white floor room air. For the highest density configurations, water-cooled in-cabinet heat exchangers are utilized. 7

Approximate power capacities for various HPC air management options: Standard cabinets Chimneys Hot/cold aisle containment Rear door heat exchangers < 8kw < 25kw < 30kw < 60kw Chilled water to cabinet cooling > 60 kw Alternating hot and cold aisles minimizes unwanted mixing of hot air around the cabinets The Importance Of Strong Floors Modern IT cabinets weigh over 2,500 pounds across 8 square feet, or over 300 pounds per square foot. This requires extraordinarily strong floors, which are typically only found in purpose-built facilities. Consider that a typical parking garage load bearing capacity is only 40 pounds per square foot! #4: Best-in-Class Equipment Capital equipment such as back-up power generators, switchgear, uninterruptible power supplies, chillers, fire suppression/detection systems, pumps and control systems collectively represent one of the biggest investments in any data center. These assets are typically refreshed on a 10-year generational lifecycle. Some data centers purchase older generations of equipment to reduce investment costs. However, a WCDC uses the newest generation of equipment because it is more reliable and more energy efficient. It is also easier to maintain, because newer systems are designed with increased component modularity and improved technician accessibility. Previous generations of data centers were built with power and cooling sufficient for a fully loaded facility, which is inefficient both in CapEx and OpEx until the facility is actually fully loaded with servers. WCDCs use a newer generation of modular equipment, so that the facility need only install and operate for required customer loads, with the ability to easily scale with additional modules as the load increases. Ed Spears, Technical Marketing Manager, Eaton Corporation The use of Best-in-Class equipment is extended to fire prevention/suppression systems as well. A WCDC will have High-Sensitivity Smoke Detection (HSSD) system like VESDA. These types of systems actively sample the air to detect overheating components and tiny smoke particles before they have a chance to grow into a fire. The sensors within these systems provide early-warning fire detection many times more sensitive than conventional spot-type fire detectors, which enables facility personnel to address problems before they result in costly downtime or potential damage. 8

550 Ton York Chiller Eaton Powerware 9395 UPS In the unlikely event a fire cannot be extinguished quickly, water should be the last resort because it is the fastest way to destroy the systems customers want protected. Instead, WCDCs use state-of-the-art FM 200 gaseous fire suppressant systems. These are stored as a liquid and dispensed as a human-safe vapor that does not obscure vision or leave any residue. These systems can extinguish most fires in 10 seconds or less, stopping ordinary combustible, electrical and flammable liquid fires before they cause significant damage to valuable customer equipment. Extinguishing a fire this quickly results in less downtime and disruption of your business while providing an extra margin of human safety for both data center staff and on-site customers. FM 200 Fire Suppression Water sprinklers should only be triggered as a last line of defense. All data centers should employ dry pipe multi-zone systems, in which the water is pressurized far away from the spray nozzles in the main equipment rooms. These dry pipes fill with water and localized sprinklers discharge only in an extreme emergency. Of course, the best way to manage fire risks is to prevent them from occurring. In a WCDC, this begins with staff that are on-site to continuously monitor early detection systems and are thoroughly trained to respond quickly and effectively using hand-held fire extinguishers if smoke, unusual heat or a fire is detected. #5: The Human Factor According to a report from the Uptime Institute, approximately 70 percent of data center downtime can be attributed to human error. One of the best ways to minimize human error is to have experienced staff on-site 24/7/365. This includes highly-skilled engineers who monitor mission-critical systems, facilities personnel to perform scheduled maintenance, and trained security provided by data center employees. 9

A WCDC design will have a purpose-planned interior to accommodate multiple users customers, security, staff, and technicians. Inherent familiarity is a fundamental objective of the design at the most basic level. Strong spatial and planning relationships between the major components create a simple ordering system to help people keep their bearings when traversing the building with consistency and order. Knowing that critical components are consistently placed from room to room throughout, the chances of mistakes are reduced. Human error plays less of a factor. Greg LaCour, Senior Associate National Mission Critical Practice Area Leader at Gensler Furthermore, because a data center is an extension of your office facilities, it is important to have a work environment that is productive, efficient, easily accessible and accommodating. A WCDC provides: A flexible work environment in which floor space can be divided into private suites for complete customer privacy Optional dedicated offices, conference rooms and seats for longer-term needs Full media conference rooms Break rooms near the colocation floor Showers in main bathrooms for extended stays No ramps or stairs from the dock to raised floor areas Workstations with wired and wireless Internet access available A streamlined security check-in process Loading docks in front of the building for convenient loading and unloading Ample, well-lit and secure parking Close to hotels, an airport, public transportation, and restaurants A work environment that is productive, efficient and accommodating. 10

Finally, the best data centers are managed in adherence with rigorous processes and controls that govern all operations, maintenance, and emergency procedures for the facility. A WCDC will be SSAE 16 Type II compliant, having successfully completed a thorough independent audit of its control environment, risk assessment process, and information and communication systems. A successful audit completion demonstrates that a service organization has ample controls in place and a higher-level commitment to support its customers. World-Class Data Centers: The Competitive Edge The only constant in business is change. The demands placed on an IT organization more uptime, greater flexibility, better security, faster growth and reduced risk will only increase with time. Collocating services at a world-class data center empowers you with capabilities to meet the inevitable challenges you will face, while giving you an advantage over your competition and offering the best protection to meet unforeseen challenges. Have you entrusted your mission-critical data and applications to a World-Class Data Center? Compare your data center to a world-class facility by downloading the Data Foundry Data Center Checklist. About Data Foundry Data Foundry provides comprehensive wholesale and retail data center outsourcing, colocation, and disaster recovery services. The company provides its customers with secure premium facilities for servers and equipment, emergency workspace and carrier-neutral network accessibility, supported by experienced onsite technicians and customer support 24/7/365. The company supports more than 1,000 enterprise customers across a variety of industries including energy, healthcare and financial services. Founded in 1994, Data Foundry was the first Internet Service Provider in San Antonio and one of the first 50 Internet Service Providers in the United States. Today, Data Foundry operates data centers in Austin and Houston and owns private networks in Austin, Houston, San Antonio and Dallas. For more information, visit www.datafoundry.com or call 1.888.839.2794. About Texas 1 Data Center Opening its doors July 2011, Data Foundry s Texas 1 is a purpose-built, 250,000 SF, carrier neutral data center located in Austin, Texas. Its unique infrastructure features independent and diverse power, water and network feeds without a single point of failure and is fully concurrently maintainable. Texas 1 s 24 megawatt power system is fed from two independent substations. The chilled water system enables flexible cooling solutions ranging from single cabinet deployments up to high-density configurations. With over 17 network carriers available, Texas 1 is the most redundant, connected, and secure data center and disaster recovery solution available in Texas. 11

1.888.839.2794 www.datafoundry.com 2012 Data Foundry. All Rights Reserved. TEXAS 1 4100 Smith School Rd Austin, TX 78744 Austin 1 7401 East Ben White Blvd, Ste 1000, Bldg One Austin, TX 78741 Houston 1 5555 San Felipe, Ste 625 Houston, TX 77056 Houston 2 660 Greens Parkway Houston, TX 77067 Proprietary and Confidential