Data Center Energy Profiler Questions Checklist
|
|
|
- Polly Walton
- 10 years ago
- Views:
Transcription
1 Data Center Energy Profiler Questions Checklist Step 1 Case Name Date Center Company State/Region County Floor Area Data Center Space Floor Area Non Data Center Space Floor Area Data Center Support Space Type of Data Center Data Center Tier (Uptime Institution Definition) Fill in the blank Fill in the blank Select from the list Select from the list Square feet or meters of data center space Square feet or meters of non data center space Square feet or meters of data center support space Select from list: Colocation, Financial, Government, Other Corporate, Managed Disaster Recovery, Telecom Switches, ISP Routers, Operations/Processing, Data Storage, or Internet Service Provider Select from list: Tier I, Tier II, Tier III, Tier IV, or mixed Current Data Center Build out Level %
2 Step 2 Energy Management Has an energy audit or commissioning been conducted within the last 2 years? Is there a written energy management plan? Is there an energy manager directly responsible for the energy management plan? (Only asked if you have a written energy management plan) Has upper management accepted the energy management plan? (Only asked if you have a written energy management plan) Is there an energy measurement and calibration program in place? Is there a preventative maintenance program in place? Data Center Energy Profiler Questions Checklist 2
3 IT Equipment Do you measure and track IT equipment (storage, server & network) utilization? Do you have a process for identifying abandoned/un-used servers and taking them offline? What is the average age at which you replace your servers? Select from the list: 0-2yrs, 3yrs, 4yrs, or 5 or more years Are you using virtualization to consolidate your server workloads? How extensive is your storage consolidation? Select from the list: 0%, 1% to 50%, 51% to 99%, or 100% What storage tiers have you implemented? (mark all that apply) Select from the list: More than one production tier, Archiving tier, or Near-line storage Have you implemented storage optimization techniques such as thin provisioning, incremental snapshots, or de-duplication? Data Center Energy Profiler Questions Checklist 3
4 Environmental Conditions What is a typical difference between supply and return air temperatures? Select from the list: 5 F (3 C), 10 F (6C), 15 F (8 C), 20 F (11 C), 25 F (14 C), 30 F (17 C), 35 F (19 C), 40 F (22 C) Has the temperature setpoint of the cooling system been optimized for the load? What is a typical (average) supply temperature? Select from the list: 45 F (7 C), 50 F (10 C), 55 F (13 C), 60 F (16 C), 65 F (18 C), 70 F (21 C), 75 F (24 C), 80 F (27 C), or >80 F (>27 C) What is a typical (average) IT equipment intake temperature? Select from the list: 50 F (10 C), 55 F (13 C), 60 F (16 C), 65 F (18 C), 70 F (21 C), 75 F (24 C), 80 F (27 C), 85 F (29 C), or >85 F (>29 C) Do you have active, working humidification controls? What type of humidifier do you have? Select from the list: (Only asked if you have a automatic humidification controls) Electric, Steam, or Direct Evaporative What is the prevalent humidification setpoint? (% RH) Select from the list: (Only asked if you have a automatic humidification controls) 20%, 30%, 40%, or 50% Do you have dehumidification controls? What is the prevalent dehumidification setpoint? (% RH) Select from the list: (Only asked if you have a automatic dehumidification controls) 40%, 50%, 60%, 70%, or 80% Where are air temperature and humidity sensors located? Select from the list: Air Return, Air Supply, IT Equipment Intake, IT Equipment Exhaust, or Other Location Do CRAC/H units have centralized (networked) or distributed controls? Select from the list: Centralized or Distributed Are there procedures and personnel/cable grounding equipment to prevent ESD? Are CRACs/CRAHs fighting each other (for example, simultaneously humidifying and dehumidifying)? Data Center Energy Profiler Questions Checklist 4
5 Does system have capability of taking slope and offset for sensor recalibration? Data Center Energy Profiler Questions Checklist 5
6 Air Management How many CRAC/CRAH/AHUs are there that operate under normal conditions? Is there any supplemental cooling? Select from the list: None, In-Row Modular, Overhead, Rear-Door, or Liquid-Cooled Cabinet Does the CRAC/CRAH/AHU have a free cooling coil (water side economizer)? Is there air-side free cooling? Air Supply Path Select from the list: Overhead Ducts, Overhead Plenum, Underfloor Plenum, or Free Is there a floor-tightness (sealing leaks) program in place? (Only asked if you employ Underfloor Plenum as your Air Supply Path) Are the cable penetrations sealed? Select from the list: 0% to 10%, 11% to 89%, or 90% to 100% Is the cable build-up in the floor plenum or the over-head plenum more than 1/3 of the plenum height? Is there a cable-mining (allow proper pressure distribution) program in place? IT equipment in rows? Is there a rack/lineup-tightness (using blanking panels) program in place? (Only asked if your IT equipment are in rows) Degree of current implementation of alternating hot and cold aisles? (Only asked if your IT equipment are in rows) Select from the list: Poor to None, Fair, or Good Degree of current efforts to minimize recirculated air at the racks (for example, blanking panels)? (Only asked if the degree of implementation is Fair or Good ) Select from the list: None to Poor, Fair, or Good Data Center Energy Profiler Questions Checklist 6
7 Degree of current efforts to minimize bypass air at the racks (for example, sealing cable penetrations in the floor)? (Only asked if the degree of implementation is Fair or Good ) Select from the list: Poor to None, Fair, or Good Supply air: Where are the overhead diffusers or perforated floor tiles places? (Only asked if the degree of implementation is Fair or Good ) Select from the list: Cold Aisles Only, Hot Aisles Only, Hot and Cold Aisles, or Not Applicable Is there a diffuser/tile-location (to conserve hot and cold aisles) program in place? (Only asked if the degree of implementation is Fair or Good ) Degree to which hot and cold aisles are currently fully enclosed? (Only asked if the degree of implementation is Fair or Good ) Select from the list: Poor to None, Fair, or Good Supply fans? Select from the list: Constant Speed or Equipped with VFDs Do some areas of the data center have load densities that are more than 4 times the average load density? Is the air-delivery system balanced to ensure correct airflow rates? Is there an air-balancing (allow proper aiflow distribution) program in place? Data Center Energy Profiler Questions Checklist 7
8 Cooling Plant Cooling system type? Select from the list: Air-Cooled DX, Water-Cooled DX, Evaporatively-Cooled DX, or Chilled Water Condenser cooling system (Asked only if you answer Water-Cooled DX or Chilled Water as your cooling system type) Select from the list: Cooling Tower or Dry Cooler Chiller type (Asked only if you answer Chilled Water as your cooling system type) Select from the list: Air-Cooled or Water-Cooled Water-side economizer (Asked only if you answer Water-Cooled as your chiller type) Select from the list: None, Integrated, or Non-Integrated Cooling tower fan control (Asked only if you answer Cooling Tower as your condenser cooling system) Select from the list: Fixed Speed, Two-Speed Motor, or VSD Type of valves (Asked only if you answer Water-Cooled DX or Chilled Water as your cooling system type) Select from the list: 2-way or 3-way Do you have premium efficiency motors on all cooling supply fans, pumps, and cooling towers that serve the data center? What is the redundancy level for HVAC systems? Select from the list: N, N+1, exceeds N+1, or 2N Data Center Energy Profiler Questions Checklist 8
9 IT Equipment Power Chain Is there an Uninterruptible Power Supply (UPS)? UPS Technology Type (Asked only if you answer Yes to having a UPS) Select from the list: Double Conversion, Delta Conversion, Rotary, or Flywheel What is the average load factor per active UPS module? (Asked only if you answer Yes to having a UPS) Select from the list: 0% to 24%, 25% to 49%, or 50% to 100% UPS Redundancy Configuration (Asked only if you answer Yes to having a UPS) Select from the list: N, N+1, or 2N Is there a standby generator? Standby Generator Power Configuration (Asked only if you have a standby generator) Select from the list: N or N+1 Is there a generator block heater? (Asked only if you have a standby generator) What is the power source for the block heater? (Asked only if you have a block heater) Utility power or Alternate source Is there a thermostat on the generator block heater? (Asked only if you have a block heater) Are there PDUs with built-in transformers? What are the types of MV and LV transformer(s)? (Asked only if have a PDUs with built-in transformers) Select from the list: Temp rise 80C, Temp rise >80C, TP1, or EPACT 2005 Average Load Factor per Active PDUs / Transformers (Asked only if have a PDUs with built-in transformers) Select from the list: 0% to 24%, 25% to 49%, or 50% to 100% Data Center Energy Profiler Questions Checklist 9
10 What is the load balance between the phases? (Asked only if have a PDUs with built-in transformers) Select from the list: Less than or equal to 20% or Greater than 20% Data Center Energy Profiler Questions Checklist 10
11 Lighting Lighting power density (watts per square foot)? How are the lights controlled? Select from the list: Manual, Occupancy Sensor, or Timer What type of lamps are used? Select from the list: T-12, T-8, or T-5 What type of ballasts are used? Select from the list: Magnetic or Electronic Data Center Energy Profiler Questions Checklist 11
12 Step 3 (Note: Questions in this section are not required to be answered.) Supplied Electricity Meter ID Use per period Unit Period Cost per period Source energy factor Supplied Fuel Meter ID Fuel Type Heating Value Use per period Unit Period Cost per period Source energy factor Imported Steam Meter ID Use per period Use Unit Temperature Temperature Unit Pressure Pressure Unit Period Cost per period Source energy factor Chilled Water Meter ID Use per period Unit Period Cost per period Source energy factor Fill in the blank Select from list: kwh, MWh, GWh, kj, MJ, GJ, TJ, MMBtu Select from list: Annual, Quarterly, Monthly Fill in the blank (numbers only, a default value is provided) Fill in the blank Select from list Select from list Select from list: Annual, Quarterly, Monthly Fill in the blank (numbers only, a default value is provided) Fill in the blank Select from list Select from list: def F, deg C, R, K Select from list: Psia, Psig, KPa, MPa, Bars, Atmosphere Select from list: Annual, Quarterly, Monthly Fill in the blank (numbers only, a default value is provided) Fill in the blank Select from list: ton-hours, MMBtu Select from list: Annual, Quarterly, Monthly Fill in the blank (numbers only, a default value is provided) Data Center Energy Profiler Questions Checklist 12
13 Step 4 (Note: Questions in this section are not required to be answered.) Electricity Energy Distribution IT Load Usage (kwh) Lights Usage (kwh) Electric Distribution Losses Usage (kwh) Fans Usage (kwh) Cooling and Humidity Controls Usage (kwh) Remainder (Non-Data Center Use) Usage (kwh) IT Load Usage (%) Lights Usage (%) Electric Distribution Losses Usage (%) Fans Usage (%) Cooling and Humidity Usage (%) Remainder (Non-Data Center Use) Usage (%) (Note: Usage can only be entered as kwh or as a percentage, not both.) Fuel Energy Distribution Cooling and Humidity Controls Usage (kwh) Remainder (Non-Data Center Use) Usage (kwh) Cooling and Humidity Usage (%) Remainder (Non-Data Center Use) Usage (%) (Note: Usage can only be entered as kwh or as a percentage, not both.) Imported Steam Cooling and Humidity Controls Usage (kwh) Remainder (Non-Data Center Use) Usage (kwh) Cooling and Humidity Usage (%) Remainder (Non-Data Center Use) Usage (%) (Note: Usage can only be entered as kwh or as a percentage, not both.) Chilled Water Cooling and Humidity Controls Usage (kwh) Remainder (Non-Data Center Use) Usage (kwh) Cooling and Humidity Usage (%) Remainder (Non-Data Center Use) Usage (%) (Note: Usage can only be entered as kwh or as a percentage, not both.) Data Center Energy Profiler Questions Checklist 13
Energy Efficiency Opportunities in Federal High Performance Computing Data Centers
Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory
CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers
CURBING THE COST OF DATA CENTER COOLING Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers OVERVIEW Compare Cooling Strategies in Free- Standing and In-Building
Best Practices. for the EU Code of Conduct on Data Centres. Version 1.0.0 First Release Release Public
Best Practices for the EU Code of Conduct on Data Centres Version 1.0.0 First Release Release Public 1 Introduction This document is a companion to the EU Code of Conduct on Data Centres v0.9. This document
Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia
Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia Prepared for the U.S. Department of Energy s Federal Energy Management Program
Green Data Centre Design
Green Data Centre Design A Holistic Approach Stantec Consulting Ltd. Aleks Milojkovic, P.Eng., RCDD, LEED AP Tommy Chiu, EIT, RCDD, LEED AP STANDARDS ENERGY EQUIPMENT MATERIALS EXAMPLES CONCLUSION STANDARDS
Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers
Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers Prepared for the U.S. Department of Energy s Federal Energy Management Program Prepared By Lawrence Berkeley National
DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER
DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTERS 2009 IT Emissions = Aviation Industry Emissions Nations Largest Commercial Consumers of Electric Power Greenpeace estimates
Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions
Free Cooling in Data Centers John Speck, RCDD, DCDC JFC Solutions Why this topic Many data center projects or retrofits do not have a comprehensive analyses of systems power consumption completed in the
Re Engineering to a "Green" Data Center, with Measurable ROI
Re Engineering to a "Green" Data Center, with Measurable ROI Alan Mamane CEO and Founder Agenda Data Center Energy Trends Benchmarking Efficiency Systematic Approach to Improve Energy Efficiency Best Practices
Defining Quality. Building Comfort. Precision. Air Conditioning
Defining Quality. Building Comfort. Precision Air Conditioning Today s technology rooms require precise, stable environments in order for sensitive electronics to operate optimally. Standard comfort air
University of St Andrews. Energy Efficient Data Centre Cooling
Energy Efficient Data Centre Cooling St. Andrews and Elsewhere Richard Lumb Consultant Engineer Future-Tech Energy Efficient Data Centre Cooling There is no one single best cooling solution for all Data
Cooling Audit for Identifying Potential Cooling Problems in Data Centers
Cooling Audit for Identifying Potential Cooling Problems in Data Centers By Kevin Dunlap White Paper #40 Revision 2 Executive Summary The compaction of information technology equipment and simultaneous
Element D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
Self-benchmarking Guide for Data Center Infrastructure: Metrics, Benchmarks, Actions 6-28-10. Sponsored by:
Self-benchmarking Guide for Data Center Infrastructure: Metrics, Benchmarks, Actions 6-28-10 Sponsored by: Disclaimer This document was prepared as an account of work sponsored by the United States Government.
Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks
Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same
White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010
White Paper Data Center Containment Cooling Strategies WHITE PAPER EC9001 Geist Updated August 2010 Abstract Deployment of high density IT equipment into data center infrastructure is now a common occurrence
International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling
Data Center Design Guide featuring Water-Side Economizer Solutions with Dynamic Economizer Cooling Presenter: Jason Koo, P.Eng Sr. Field Applications Engineer STULZ Air Technology Systems jkoo@stulz ats.com
Analysis of data centre cooling energy efficiency
Analysis of data centre cooling energy efficiency An analysis of the distribution of energy overheads in the data centre and the relationship between economiser hours and chiller efficiency Liam Newcombe
How To Improve Energy Efficiency In A Data Center
Google s Green Data Centers: Network POP Case Study Table of Contents Introduction... 2 Best practices: Measuring. performance, optimizing air flow,. and turning up the thermostat... 2...Best Practice
Data Centers: How Does It Affect My Building s Energy Use and What Can I Do?
Data Centers: How Does It Affect My Building s Energy Use and What Can I Do? 1 Thank you for attending today s session! Please let us know your name and/or location when you sign in We ask everyone to
Green Data Centers development Best Practices
Draft Recommendation ITU-T L.DC Green Data Centers development Best Practices Summary This recommendation is a contribution for the reduction of negative climate impact of Data Centers.
AIA Provider: Colorado Green Building Guild Provider Number: 50111120. Speaker: Geoff Overland
AIA Provider: Colorado Green Building Guild Provider Number: 50111120 Office Efficiency: Get Plugged In AIA Course Number: EW10.15.14 Speaker: Geoff Overland Credit(s) earned on completion of this course
Data Center Power Consumption
Data Center Power Consumption A new look at a growing problem Fact - Data center power density up 10x in the last 10 years 2.1 kw/rack (1992); 14 kw/rack (2007) Racks are not fully populated due to power/cooling
Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore
Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore Introduction Agenda Introduction Overview of Data Centres DC Operational
White Paper #10. Energy Efficiency in Computer Data Centers
s.doty 06-2015 White Paper #10 Energy Efficiency in Computer Data Centers Computer Data Centers use a lot of electricity in a small space, commonly ten times or more energy per SF compared to a regular
UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms
Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms By Neil Rasmussen White Paper #49 Executive Summary Avoidable mistakes that are routinely made when installing cooling
Best Practices in HVAC Design/Retrofit
Best Practices in HVAC Design/Retrofit Little Server Room BIG $AVINGS Justin Lewis, P.E., LEED AP, DCEP Sr Energy Project Manager C:530.400.6042 O:530.754.4870 [email protected] 1 What s the problem here?
Stanford University Server/Telecom Rooms Design Guide
Stanford University Server/Telecom Rooms Design Guide CONTENTS 1.0 How to Use this Guide...3 1.1 Document Organization...3 2.0 Summary Form and Sample Options Matrix...3 3.0 Options Matrix...7 4.0 Recommended
Benefits of. Air Flow Management. Data Center
Benefits of Passive Air Flow Management in the Data Center Learning Objectives At the end of this program, participants will be able to: Readily identify if opportunities i where networking equipment
7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
Example Retrocommissioning Measure: Opening Throttled Discharge Valves
Opening Throttled Discharge Valves This 21-story building, constructed in 1997, is located in Oregon and contains 589,000 gross square feet of mostly office occupancy. The HVAC system includes six large
Dealing with Thermal Issues in Data Center Universal Aisle Containment
Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe [email protected] AGENDA Business Drivers Challenges
National Grid Your Partner in Energy Solutions
National Grid Your Partner in Energy Solutions National Grid Webinar: Enhancing Reliability, Capacity and Capital Expenditure through Data Center Efficiency April 8, 2014 Presented by: Fran Boucher National
Center Thermal Management Can Live Together
Network Management age e and Data Center Thermal Management Can Live Together Ian Seaton Chatsworth Products, Inc. Benefits of Hot Air Isolation 1. Eliminates reliance on thermostat 2. Eliminates hot spots
Recommendation For Incorporating Data Center Specific Sustainability Best Practices into EO13514 Implementation
Recommendation For Incorporating Data Center Specific Sustainability Best Practices into EO13514 Implementation Version 1.0 - November, 2011 Incorporating Data Center-Specific Sustainability Measures into
Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.
Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED. Presentation Goals & Outline Power Density Where we have been- where we are now - where we are going Limitations of Air Cooling
How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems
How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems Paul Mathew, Ph.D., Staff Scientist Steve Greenberg, P.E., Energy Management Engineer
Data center upgrade proposal. (phase one)
Data center upgrade proposal (phase one) Executive Summary Great Lakes began a recent dialogue with a customer regarding current operations and the potential for performance improvement within the The
Scalable. Affordable. Flexible. Fast.
Modular Data Center Solutions Scalable. Affordable. Flexible. Fast. Build the data center you need today with the flexibility to meet tomorrow s challenges The only constant in business is change. Fluctuations
Managing Cooling Capacity & Redundancy In Data Centers Today
Managing Cooling Capacity & Redundancy In Data Centers Today About AdaptivCOOL 15+ Years Thermal & Airflow Expertise Global Presence U.S., India, Japan, China Standards & Compliances: ISO 9001:2008 RoHS
Elements of Energy Efficiency in Data Centre Cooling Architecture
Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total
Environmental Data Center Management and Monitoring
2013 Raritan Inc. Table of Contents Introduction Page 3 Sensor Design Considerations Page 3 Temperature and Humidity Sensors Page 4 Airflow Sensor Page 6 Differential Air Pressure Sensor Page 6 Water Sensor
DESIGN ASPECT OF ENERGY EFFICIENT DATA CENTER
DESIGN ASPECT OF ENERGY EFFICIENT DATA CENTER Omendra K. Govind 1, Annu Govind 2 1 Advanced Level Telecom Training Centre (ALTTC), BSNL, Ghaziabad,(India) 2 Research Scholar, Department of Electrical Engineering,
Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency
Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency A White Paper from the Experts in Business-Critical Continuity TM Executive Summary As electricity prices and IT
2010 Best Practices. for the EU Code of Conduct on Data Centres. Version 2.0.0 Release Public Review Public
2010 Best Practices for the EU Code of Conduct on Data Centres Version 2.0.0 Release Public Review Public 1 Document Information 1.1 Version History Version 1 Description Version Updates Date 2.0.0 2010
Reducing Data Center Loads for a Large-Scale, Net Zero Office Building
rsed Energy Efficiency & Renewable Energy FEDERAL ENERGY MANAGEMENT PROGRAM Reducing Data Center Loads for a Large-Scale, Net Zero Office Building Energy Efficiency & Renewable Energy Executive summary
Energy Efficient High-tech Buildings
Energy Efficient High-tech Buildings Can anything be done to improve Data Center and Cleanroom energy efficiency? Bill Tschudi Lawrence Berkeley National Laboratory [email protected] Acknowledgements California
Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs
WHITE PAPER Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs By Lars Strong, P.E., Upsite Technologies, Inc. 505.798.000 upsite.com Reducing Room-Level
Data Center Components Overview
Data Center Components Overview Power Power Outside Transformer Takes grid power and transforms it from 113KV to 480V Utility (grid) power Supply of high voltage power to the Data Center Electrical Room
Blade Server & Data Room Cooling Specialists
SURVEY I DESIGN I MANUFACTURE I INSTALL I COMMISSION I SERVICE SERVERCOOL An Eaton-Williams Group Brand Blade Server & Data Room Cooling Specialists Manufactured in the UK SERVERCOOL Cooling IT Cooling
Data Centers WHAT S ONTHEHORIZON FOR NR HVAC IN TITLE 24 2013? SLIDE 1
WHAT S ONTHEHORIZON FOR NR HVAC IN TITLE 24 2013? SLIDE 1 Data Center CASE Scope Existing Title 24 2008 Scope Current scope ( 100 T24-2008) exempts process space from many of the requirements, however
Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures
Data Realty Colocation Data Center Ignition Park, South Bend, IN Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures Project Overview Data Realty is a data center service provider for middle
DOE FEMP First Thursday Seminar. Learner Guide. Core Competency Areas Addressed in the Training. Energy/Sustainability Managers and Facility Managers
DOE FEMP First Thursday Seminar Achieving Energy Efficient Data Centers with New ASHRAE Thermal Guidelines Learner Guide Core Competency Areas Addressed in the Training Energy/Sustainability Managers and
Data Centre Testing and Commissioning
Data Centre Testing and Commissioning What is Testing and Commissioning? Commissioning provides a systematic and rigorous set of tests tailored to suit the specific design. It is a process designed to
QUALITATIVE ANALYSIS OF COOLING ARCHITECTURES FOR DATA CENTERS
WHITE PAPER #30 QUALITATIVE ANALYSIS OF COOLING ARCHITECTURES FOR DATA CENTERS EDITOR: Bob Blough, Emerson Network Power CONTRIBUTORS: John Bean, APC by Schneider Electric Robb Jones, Chatsworth Products
News in Data Center Cooling
News in Data Center Cooling Wednesday, 8th May 2013, 16:00h Benjamin Petschke, Director Export - Products Stulz GmbH News in Data Center Cooling Almost any News in Data Center Cooling is about increase
Benefits of Cold Aisle Containment During Cooling Failure
Benefits of Cold Aisle Containment During Cooling Failure Introduction Data centers are mission-critical facilities that require constant operation because they are at the core of the customer-business
Unified Physical Infrastructure (UPI) Strategies for Thermal Management
Unified Physical Infrastructure (UPI) Strategies for Thermal Management The Importance of Air Sealing Grommets to Improving Smart www.panduit.com WP-04 August 2008 Introduction One of the core issues affecting
Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers
A White Paper from the Experts in Business-Critical Continuity TM Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers Executive Summary The strategic business importance
Best Practices Guide for Energy-Efficient Data Center Design
FEDERAL ENERGY MANAGEMENT PROGRAM Best Practices Guide for Energy-Efficient Data Center Design Revised March 2011 Prepared by the National Renewable Energy Laboratory (NREL), a national laboratory of the
Improving Data Center Energy Efficiency Through Environmental Optimization
Improving Data Center Energy Efficiency Through Environmental Optimization How Fine-Tuning Humidity, Airflows, and Temperature Dramatically Cuts Cooling Costs William Seeber Stephen Seeber Mid Atlantic
Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001
Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001 Presented by: Liberty Engineering, LLP 1609 Connecticut Avenue
Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009
Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009 Agenda Overview - Network Critical Physical Infrastructure Cooling issues in the Server Room
HVAC Simplified Approach Option
HVAC Simplified Approach Option Part I Project Address: City: HVAC System Designer of Record: Date: Zip: Qualification The building is 2 stories or less in height and has a gross floor area is less than
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER
Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER Lylette Macdonald, RCDD Legrand Ortronics BICSI Baltimore 2011 Agenda: Discuss passive thermal management at the Rack
The New Data Center Cooling Paradigm The Tiered Approach
Product Footprint - Heat Density Trends The New Data Center Cooling Paradigm The Tiered Approach Lennart Ståhl Amdahl, Cisco, Compaq, Cray, Dell, EMC, HP, IBM, Intel, Lucent, Motorola, Nokia, Nortel, Sun,
APC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency
A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency
Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling
Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling Joshua Grimshaw Director of Engineering, Nova Corporation
- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
HVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group
GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY Public Sector ICT Special Working Group SERVER ROOM ENERGY EFFICIENCY This guide is one of a suite of documents that aims to provide guidance on ICT energy efficiency.
How To Run A Data Center Efficiently
A White Paper from the Experts in Business-Critical Continuity TM Data Center Cooling Assessments What They Can Do for You Executive Summary Managing data centers and IT facilities is becoming increasingly
How to Build a Data Centre Cooling Budget. Ian Cathcart
How to Build a Data Centre Cooling Budget Ian Cathcart Chatsworth Products Topics We ll Cover Availability objectives Space and Load planning Equipment and design options Using CFD to evaluate options
Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings
Advanced Energy Design Guide LEED Strategies for Schools and High Performance Buildings Today s Presenters Stephen Koontz, LEED AP Energy Services Leader Tampa Bay Trane Allen Irvine General Sales Manager
HEATING, VENTILATION & AIR CONDITIONING
HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating
How to Meet 24 by Forever Cooling Demands of your Data Center
W h i t e P a p e r How to Meet 24 by Forever Cooling Demands of your Data Center Three critical aspects that are important to the operation of computer facilities are matching IT expectations with the
Legacy Data Centres Upgrading the cooling capabilities What are the options?
Legacy Data Centres Upgrading the cooling capabilities What are the options? Presentation Structure What is a Legacy Data Centre? What is CRAC cooling? ASHRAE Standards Overview Available Cooling Systems
KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM
KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM AIR HANDLING UNITS... 1 CHILLERS... 2 COOLING TOWERS... 2 CLOSED LOOP COOLERS... 2 MISCELLANEOUS SUPPLY FANS...
Energy Recovery Systems for the Efficient Cooling of Data Centers using Absorption Chillers and Renewable Energy Resources
Energy Recovery Systems for the Efficient Cooling of Data Centers using Absorption Chillers and Renewable Energy Resources ALEXANDRU SERBAN, VICTOR CHIRIAC, FLOREA CHIRIAC, GABRIEL NASTASE Building Services
Energy and Cost Analysis of Rittal Corporation Liquid Cooled Package
Energy and Cost Analysis of Rittal Corporation Liquid Cooled Package Munther Salim, Ph.D. Yury Lui, PE, CEM, LEED AP eyp mission critical facilities, 200 west adams street, suite 2750, Chicago, il 60606
Data Center Infrastructure Management (DCIM) Utility Energy Efficiency Opportunities Discussion & Demos July 2, 2013
Data Center Infrastructure Management (DCIM) Utility Energy Efficiency Opportunities Discussion & Demos July 2, 2013 Ted Brown Sr. Energy Management Analyst Data Center / IT Energy Efficiency [email protected]
Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
Alan Matzka, P.E., Senior Mechanical Engineer Bradford Consulting Engineers
Information Technology and Data Centers HVAC Showcase November 26, 2013 Alan Matzka, P.E., Senior Mechanical Engineer Bradford Consulting Engineers Welcome. Today s webinar is being recorded and will be
Choosing Close-Coupled IT Cooling Solutions
W H I T E P A P E R Choosing Close-Coupled IT Cooling Solutions Smart Strategies for Small to Mid-Size Data Centers Executive Summary As high-density IT equipment becomes the new normal, the amount of
NetApp Data Center Design
NetApp Data Center Design Presentation for SVLG Data Center Efficiency Summit November 5, 2014 Mark Skiff, PE, CEM, CFM Director, IT Data Center Solutions Data Center Design Evolution Capacity Build Cost
European Code of Conduct for Data Centre. Presentation of the Awards 2014
European Code of Conduct for Data Centre Presentation of the Awards 2014 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Results European
Using thermal mapping at the data centre
Technical Using thermal mapping at the data centre by Gregory Stockton, CompuScanIR.com Cooling the servers in data centres efficiently is critical to increasing IT reliability, maintaining high performance,
Data Center Leadership In the DOE Better Buildings Challenge
Symposium Southern California February 18th, 2015 Data Center Leadership In the DOE Better Buildings Challenge Applying Best Practices to meet the Challenge Dale Sartor, PE Lawrence Berkeley National Laboratory
Power and Cooling for Ultra-High Density Racks and Blade Servers
Power and Cooling for Ultra-High Density Racks and Blade Servers White Paper #46 Introduction The Problem Average rack in a typical data center is under 2 kw Dense deployment of blade servers (10-20 kw
STULZ Water-Side Economizer Solutions
STULZ Water-Side Economizer Solutions with STULZ Dynamic Economizer Cooling Optimized Cap-Ex and Minimized Op-Ex STULZ Data Center Design Guide Authors: Jason Derrick PE, David Joy Date: June 11, 2014
Rittal Liquid Cooling Series
Rittal Liquid Cooling Series by Herb Villa White Paper 04 Copyright 2006 All rights reserved. Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Phone +49(0)2772 / 505-0 Fax +49(0)2772/505-2319 www.rittal.de