1 Raised Floor Data Centers Prepared for the Future
2 Raised Floors Protect My Investment by Providing a Foundation for Current and Future Technologies.
3 Creating the Future Proof Data Center Environment The perfect data center environment requires the ability to handle a large number of data cables, the ability to efficiently handle high heat loads that are variable and diverse, and the ability to adapt for future technological and cooling advancements. Tate s system addresses all of these needs in a highly adaptable space that provides the ability to respond quickly and easily to client, organizational and technological changes all while being costeffective in both construction and operation. With Tate s access flooring solutions, you ll be able to address all of the demands of a data center while meeting the everyday needs of its users in a secure and reliable environment. Advantages of a Raised Floor Enhanced cooling capabilities and control. Ability to accommodate a range of cooling solutions while increasing efficiency and heat load capacities. Easily incorporate redundant cooling with a single or multiple cooling strategies. Flexibility to incorporate the most energy efficient design opportunities for cooling data centers. Easily adapt to technological and client changes over the data center s life-cycle at low cost. Offers the best overall solution for distributing water and other liquid cooling agents to row and rack based equipment. Water distribution lines placed under a raised floor pose less threat in the event of water leaks or condensation due to system failure. Provides the ability to separate water, power and cable. Ability to terminate cables wherever you need them with complete flexibility, accessibility, and unlimited capacity. Reduced operating costs and lower facility and maintenance costs through accessible, flexible, and adaptable services. Underfloor service distribution space keeps the interior space clean and neat for proper air migration in-and-out of equipment. Raised floors provide the platform for future scalability. 3
4 Raised Floors Compliment Any Data Center Design Flexible, Adaptable, Scalable & Efficient These four words are the cornerstone of what data center designers, owners and managers strive to create in their facility. The raised floor environment is perfectly suited to provide them all. Managing and segregating large volumes of wires, cables, water lines and other distribution systems is complemented with a raised floor. As equipment is updated and technology changes, additional services can be added or relocated without abandonment or structural changes. The build-out of a raised floor can be easily stopped and started for a phased approach. And raised floors provide the platform to easily implement any current or future cooling strategy for optimal energy efficiency. Economized Air Handlers pull large volumes of air from outside and pressurizes a raised floor plenum to cool the equipment. (page 17) Full Containment solutions are used to prevent cold air from mixing with hot air. (page 15) Row Based Cooling solutions use a pumping unit to supply water feeds underfloor to in row cooling equipment. (page 11) The Data Center Design is Constantly Changing. 4
5 Rear Door Exhaust Systems use pumping units to supply water feeds under a raised floor to rack mounted equipment. (page 12) Perimeter CRAC Units use a pressurized plenum to deliver cool air under the raised floor and to the racks for both primary and back-up cooling. (page 6) In-Floor Cooling Devices used in conjunction with perimeter CRAC unit or economized solutions to save energy and improve capacity. (page 8) Overhead Heat Exchanger use refrigerant pumping units which require an open overhead area for airflow, refrigerant lines and equipment. (page 14) Future Unknown Cooling Temporary walls and Tate s plenum divider can be used to section off space for future expansion. Raised floors provide flexibility to meet unknown future demands. Will Your Data Center be Ready for What s Next... 5
6 Raised Floor Data Centers Perimeter CRAC Unit Design The most common data center design uses a perimeter CRAC or CRAH unit and raised floor to provide the ultimate in air flow distribution flexibility. The under floor plenum space allows the user to selectively distribute air at the volume required so equipment changes can be accommodated more cost effectively. The use of interchangeable perforated panels, and high air flow grates in both the floor and the ceiling, coupled with the high efficiency down flow CRAC and CRAH units equipped with Tate s CRAC Hood return extension allows the user to realize significant energy savings, while allowing the flexibility that the data center operator has come to expect. Advantages of a Raised Floor Enhanced cooling capabilities and control Easily reconfigured to accommodate moves, adds and changes Air flow variability from CFM accommodating loads as high as 30kW per rack Floor heights over four feet provide virtually unlimited cabling and air flow capacity in easy to access under floor area. Reduced operating cost and lower facility and maintenance cost through accessible, flexible and adaptable services Removable barriers can be easily installed to divide plenum space for future scalability Provides underfloor service distribution path for power and network cabling without the use of a ladder or enhanced structural cable trays and ceilings. 6
7 7 Facility Solutions: Digital Realty Trust
8 Raised Floor Data Centers In-Floor Cooling Devices In-floor cooling devices are relatively new and provide a level of control and capacity that was previously unavailable in a traditional CRAC or CRAH unit design. Controlled on a rack-by-rack level these new devices use directionality (DirectAire ), variable air volume dampers (SmartAire ) and floor mounted fans (PowerAire ) to provide exactly the right amount of airflow where it s needed. The use of rack mounted sensors, and high air flow directional grates, coupled with down flow CRAC and CRAH units using VFD or EC fans allows the user to realize significant energy savings. This savings is gained through several benefits including the ability to deliver higher volumes of air at lower static pressures, the control to deliver exactly the right amount of air needed to cool the equipment, and the significant reduction of by-pass air. Advantages of a Raised Floor Provides mounting platform for devices to provided airflow control on an individual rack-by-rack basis. Significant energy savings when devices are used with CRAC units and air handlers equiped with VFD or EC fans Provides effective containment without walls or structures Air flow variability from CFM accommodating loads as high as 30kW per rack Accessible, flexible and adaptable service distribution platform allows for retrofit of devices into existing data centers Provides ability to easily handle diverse and variable heat loads. In-Floor Cooling Devices From Tate Sensor Mounted to the Front of the Rack Cable Cut-out Seal for Distributing Sensors DirectAire, High Volume Directional Grate SmartAire, Variable Air Volume Damper PowerAire, Fan Assist Module SmartAire, Power Distribution Module DirectAire Panel Lifter 8
9
10 10 Facility Solutions: Row Based Cooling Data Center
11 Raised Floor Data Centers Row and Rack Based Water Cooled cooling units to the IT load is intended to reduce hot and cold air mixing, and the typical use of variable speed fans and chilled water throttling also help reduce the energy usage of this type of deployment. Row and rack based cooling is also scalable on the data center floor for future expansion and equipment changes. Advantages of a Raised Floor Open plumbing routing space under the Raised Floor provides an easily scalable cooling infrastructure, systems can be installed when and where required Row and Rack based cooling systems provide the ability to bring individual cooling system to the IT load, focusing on meeting the heat rejection requirements directly at the load. The row and rack based units typically are fed from a chilled water source in the data center and reject the heat energy from the IT equipment into the chilled water loop. These systems can be spread over multiple racks on the data center raised floor, or dedicated to specific high density racks as a retrofit or spot cooling solution. Closer proximity of the Raised Floor provides a safe and convenient location for pipe work, and piping connections Underfloor piping mitigates the risks associated with condensation and leaks Raised Floor can be utilized for redundant cooling source such as perimeter CRAC units and air side economizers Raised Floor provides a path for other service distribution such as power and network cabling in addition to chilled water piping 11
12 Raised Floor Data Centers Rear Door Heat Exchanger Rear Door heat exchangers replace the standard rear door on the IT rack and provide a direct path for heat rejection from the IT equipment through an air to water heat exchanger. The directly coupled nature, and in some cases the elimination of fans in the door itself can result in significant energy savings compared to other cooling technologies. Much like Row and Rack based cooling systems chilled water must be ran to each rear door heat exchanger. Chilled water must often be first ran to a coolant distribution unit, and then piped individually out to the rear door heat exchangers. There are many advantages to piping these conections under a raised floor including the use of a CRAC unit for redundant cooling. As shown in the picture below any through floor wire cable and piping connections should be sealed using TateKOLDLOK grommet to eliminate air leakage. Advantages of a Raised Floor Chilled water piping can be safely and conveniently accommodated under the raised floor Raised floor with perimeter CRAC unit can serve as a means for redundant cooling The raised floor provides a safe and convenient location for pipe work, and piping connections Underfloor piping mitigates the risks associated with condensation and leaks Raised Floor provides a path for other service distribution such as power and network cabling in addition to chilled water piping Easily scalable, offering the user quick access to plumbing below the floor for additional installations 12
13 Facility Solutions: Syracuse University - IBM Data Center Syracuse University has been named one of the 2010 Green 15 by GDC's InfoWorld for its innovative Green Data Center. The annual Green 15 award recognizes the 15 most innovative IT initiatives of organizations around the world that have embraced green technology to drive projects and develop products aimed at boosting energy efficiency, trimming waste, and reducing or eliminating the use or the production of harmful substances. A collaboration of SU, IBM and New York State, the GDC has been hailed as one of the world s greenest computer centers, designed to use about 50 percent less energy than a typical data center. The $12.4 million, 12,000-square-foot facility (6,000 square feet of infrastructure space and 6,000 square feet of raised-floor data center space) was completed in early December 2009 and became fully operational in April The GDC is used by SU as its primary computing facility and by IBM as a showcase to demonstrate how energy-efficient technologies can reduce energy costs and environmental impact. Tate Access Floors for Data Centers: The Syracuse University Green Data Center is equipped with 40 floor heights to provide the necessary space for multiple functions. The primary cooling method used in the data center is rear door heat exchangers mounted to each rack. These units directly cool the hot air from the IT equipment, and return it into the space at the required temperature for equipment to take back in reheat, and pass back again through the rear door heat exchanger. The raised floor is used to route the chilled water lines from the facility to the rear door units in a safe manner. The racks in the space are also a large consumer of electricity, and the power cabling is passed from the power distribution unit, via power whips under the floor to each rack. Finally the raised floor space is also used as a means of backup cooling. CRAH units are installed around the perimeter of the facility, and can provide additional or redundant cooling to the mission critical IT hardware in case of other cooling system loss of capacity. 13
14 Raised Floor Data Centers Overhead Heat Exchanger Overhead and above rack cooling systems have quickly become an accepted method for adding additional cooling capacity to high density rows of equipment. These systems are meant to compliment perimeter CRAC and CRAH unit designs to provide additional air delivery to the cold aisle. Refrigerant piping is routed overhead to a pumping unit which handles the exchanges from refrigerant to chilled water or outdoor air. Since these systems are design to add capacity where perimeter CRAC and CRAH units can no longer supply adequate cooling, the raised floor area is often utilized in the same way. Air is still delivered under the raised floor to the equipment in the low, medium and high density zones, and additional cold air is delivered where it is needed in those zones, allowing for a precisely provisioned data center. Raised floors further complement this design by proving a distribution path for wires and cables that do not obstruct the distribution of cooling lines and overhead equipment. Advantages of a Raised Floor Dual airflow paths allow for redundancy in mission critical locations Raised floor space is used for power and cabling distribution to allow for overhead design of equipment and refrigerant lines Separation of chilled water lines feeding the pumping unit, power cables, networking infrastructure and air flow is all possible 14
15 Raised Floor Data Centers Full Containment Solutions Total containment systems such as Tate s ContainAire prevents the cold supply air from mixing with the hot exhaust air prior to being ingested by the data center equipment. This is accomplished through several variations that contain either the hot or cold air while allowing the other to flow freely throughout the space. Hot or cold aisle containment typically features side wall barriers mounted to the racks at each end of a row with a roof that is either mounted to the top of the racks or extending from the top of the rack to the ceiling. Exhaust chimneys are a common variation of hot aisle containment where chimney structures are attached directly to the back of the racks to allow the hot air to move to the ceiling plenum without mixing with the cooler space air. This system allows the aisles to remain free of obstructions. Since these systems are design to add capacity and energy efficiency by eliminating mixing, the raised floor area is often utilized as a supply plenum to deliver the air directly to the cold aisle. Raised floors further complement this design by proving a distribution path for wires and cables that do not obstruct or penetrate the containment system walls. Advantages of a Raised Floor Enhanced cooling capabilities, control and efficiency Easy supply source for air flow variability from CFM to accommodate virtually any high density heat load Raised floor space is used for power and cabling distribution to allow for air tight aisle containment without penetrations 15
16 16 Facility Solutions: Manassas Colocation Facility
17 Raised Floor Data Centers Economizer Design The use of air side economizing in the data center space has come into its own in recent years as one of the key ways to reduce the energy usage in the data center space. Historically deployed with containment methods and raised access floor, the overall impact on the data center energy bill is significant. The raised floor plenum provides the ideal initial pathway from the economizing system. Now when the system is deployed using Tate s DirectAire to deliver air precisely where it is needed; containment systems can be eliminated ensuring that the outdoor air does not mix with the hot exhaust air prior to entering the rack. Advantages of a Raised Floor Varied raised floor heights can accommodate the required air flow volumes for any desired capacity Raised floor space can accommodate cabling for network and power for ease of deploying containment strategies Back-up cooling equipment can easily be added to the same air distribution system Deploying with Tate s DirectAire grate eliminates the need for a full containment system 17
18 Prepare Your Data Center for the Future With the ever increasing requirements for flexibility, capacity, and efficiency in the data center, the raised floor environment will continue to provide a key platform to deliver critical services. Recent years have brought dramatic changes in the way data centers are built and operated, everything from the infrastructure and cooling to computing equipment and management have undergone significant adaptations. Most notably, we have seen the raised floor data center environment transform from a traditional perimeter CRAC or CRAH only approach to a multifaceted array of solutions applied on the raised floor to accommodate both capacity, efficiency and redundancy requirements. The need for scalability, modularity, and flexibility coupled with the array of solutions available on the market make the need for a raised floor in a data centers easy to understand. New technologies are adopted and implemented very quickly in the data center. This requires facilities to be built so they can accommodate current systems while being flexible enough to protect the investment and remain reliable and competitive in an unknown future. With raised floors in your data center the future is bright. Enhanced cooling capabilities and control. Ability to increase efficiency and heat load capacities. Adapt to technological changes over the life of the data center. Easily distribute & segregate water, power and cable. Terminate services in a flexible and adaptable platform. Clean & neat interior space to ensure proper air migration inand-out of equipment. The platform for know & unknown future scalability. 18
19 Raised Floors Provide My Data Center the Flexibility, Capacity and Energy Efficiency to Operate Successfully.
20 Data Center Products Visit for more information SmartAire VAV damper to automatically control airflow at the rack level improving energy efficiency. DirectAire 68% open area all steel panel that angles airflow to achieve a 93% TAC rate. PowerAire Fan assisted airflow at the rack level for handling extremely high & diverse heat loads. GrateAire 56% open area aluminum grate capable of delivering 2100 H2O. Corporate Headquarters: 7510 Montevideo Road, Jessup, MD Tate Hotline: Tel: Fax: Production Facilities: 7510 Montevideo Road, Jessup, MD Springvale Road, Red Lion, PA tateaccessfloors.com kingspan.com International Sales & Support Office: 169 Jalan Jurong Kechil #7-011, Sherwood Singapore Tel: Fax: tateglobal.com kingspan.com Tate Access Floors, Inc. components are proudly made in the U.S.A. Canadian Office & Production Facilities: 880 Equestrian Court, Oakville, ON L6L 6L7 Canada Tate Hotline: Tel: Fax: tateasp.com kingspan.com For a white paper on Long Term Flexibility Raised Access Floor and the Future of Data Center Cooling visit resources/white_papers.aspx A member of Tate Building Technology Platform, ConCore, GrateAire, PosiLock, PosiTile, PVD Servicenter, Floating Floors, Integral Trim, SustainAbility and AirArrest are registered trademarks of Tate Access Floors, Inc. DirectAire TM, SmartAire and PowerAire are Trademarks of Tate Access Floors Inc Tate Access Floors, Inc. Revised 2010
Data Center Optimization Services. Maximize Your Data Center
Data Center Optimization Services Maximize Your Data Center Energy savings was definitely the key driver in my decision to use the SmartAire dampers and DirectAire panels. - Larry Hood Senior Construction
Tate s Wire & Cable Solution
Access Floors Tate s Wire & Cable Solution A Flexible & Sustainable Management System Access Flooring to the Power of Your company will discover complete flexibility and reconfiguration capability 2 Creating
In-Floor Cooling Solutions. In-Floor Cooling Solutions. Airfl ow Management Solutions for Raised Floor Data Centers
In-Floor Cooling Solutions In-Floor Cooling Solutions Airfl ow Management Solutions for Raised Floor Data Centers Virtual Aisle Containment In-floor Cooling Airflow Panels and Controls Virtual containment
Unified Physical Infrastructure (UPI) Strategies for Thermal Management
Unified Physical Infrastructure (UPI) Strategies for Thermal Management The Importance of Air Sealing Grommets to Improving Smart www.panduit.com WP-04 August 2008 Introduction One of the core issues affecting
AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings
WH I TE PAPE R AisleLok Modular Containment vs. : A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings By Bruce Long, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies,
Choosing Close-Coupled IT Cooling Solutions
W H I T E P A P E R Choosing Close-Coupled IT Cooling Solutions Smart Strategies for Small to Mid-Size Data Centers Executive Summary As high-density IT equipment becomes the new normal, the amount of
Power and Cooling for Ultra-High Density Racks and Blade Servers
Power and Cooling for Ultra-High Density Racks and Blade Servers White Paper #46 Introduction The Problem Average rack in a typical data center is under 2 kw Dense deployment of blade servers (10-20 kw
Rittal Liquid Cooling Series
Rittal Liquid Cooling Series by Herb Villa White Paper 04 Copyright 2006 All rights reserved. Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Phone +49(0)2772 / 505-0 Fax +49(0)2772/505-2319 www.rittal.de
Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers
Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers Deploying a Vertical Exhaust System www.panduit.com WP-09 September 2009 Introduction Business management applications and rich
How to Meet 24 by Forever Cooling Demands of your Data Center
W h i t e P a p e r How to Meet 24 by Forever Cooling Demands of your Data Center Three critical aspects that are important to the operation of computer facilities are matching IT expectations with the
CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers
CURBING THE COST OF DATA CENTER COOLING Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers OVERVIEW Compare Cooling Strategies in Free- Standing and In-Building
Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency
A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency
Energy Efficiency Opportunities in Federal High Performance Computing Data Centers
Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory
Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009
Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009 Agenda Overview - Network Critical Physical Infrastructure Cooling issues in the Server Room
Dealing with Thermal Issues in Data Center Universal Aisle Containment
Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe [email protected] AGENDA Business Drivers Challenges
The Different Types of Air Conditioning Equipment for IT Environments
The Different Types of Air Conditioning Equipment for IT Environments By Tony Evans White Paper #59 Executive Summary Cooling equipment for an IT environment can be implemented in 10 basic configurations.
Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs
WHITE PAPER Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs By Lars Strong, P.E., Upsite Technologies, Inc. 505.798.000 upsite.com Reducing Room-Level
Managing Data Centre Heat Issues
Managing Data Centre Heat Issues Victor Banuelos Field Applications Engineer Chatsworth Products, Inc. 2010 Managing Data Centre Heat Issues Thermal trends in the data centre Hot Aisle / Cold Aisle design
How To Run A Data Center Efficiently
A White Paper from the Experts in Business-Critical Continuity TM Data Center Cooling Assessments What They Can Do for You Executive Summary Managing data centers and IT facilities is becoming increasingly
Containment Solutions
Containment Solutions Improve cooling efficiency Separate hot and cold air streams Configured to meet density requirements Suitable for commercial and SCEC endorsed cabinets Available for retrofit to SRA
APC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.
Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED. Presentation Goals & Outline Power Density Where we have been- where we are now - where we are going Limitations of Air Cooling
Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions
Free Cooling in Data Centers John Speck, RCDD, DCDC JFC Solutions Why this topic Many data center projects or retrofits do not have a comprehensive analyses of systems power consumption completed in the
Best Practices for Wire-free Environmental Monitoring in the Data Center
White Paper 11800 Ridge Parkway Broomfiled, CO 80021 1-800-638-2638 http://www.42u.com [email protected] Best Practices for Wire-free Environmental Monitoring in the Data Center Introduction Monitoring for
Element D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
In Row Cooling Options for High Density IT Applications
In Row Cooling Options for High Density IT Applications By Ramzi Y. Namek, PE, LEED AP, BD+C; Director of Engineering 1 Users wishing to deploy high density IT racks have several In Row Cooling solutions
- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
APC APPLICATION NOTE #92
#92 Best Practices for Designing Data Centers with the InfraStruXure InRow RC By John Niemann Abstract The InfraStruXure InRow RC is designed to provide cooling at the row and rack level of a data center
Data center upgrade proposal. (phase one)
Data center upgrade proposal (phase one) Executive Summary Great Lakes began a recent dialogue with a customer regarding current operations and the potential for performance improvement within the The
Strategies for Deploying Blade Servers in Existing Data Centers
Strategies for Deploying Blade Servers in Existing Data Centers By Neil Rasmussen White Paper #125 Revision 1 Executive Summary When blade servers are densely packed, they can exceed the power and cooling
Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling
Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling Joshua Grimshaw Director of Engineering, Nova Corporation
Rack Hygiene. Data Center White Paper. Executive Summary
Data Center White Paper Rack Hygiene April 14, 2011 Ed Eacueo Data Center Manager Executive Summary This paper describes the concept of Rack Hygiene, which positions the rack as an airflow management device,
Managing Cooling Capacity & Redundancy In Data Centers Today
Managing Cooling Capacity & Redundancy In Data Centers Today About AdaptivCOOL 15+ Years Thermal & Airflow Expertise Global Presence U.S., India, Japan, China Standards & Compliances: ISO 9001:2008 RoHS
Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA
Paul Oliver Sales Director Paul Oliver, Airedale Tom Absalom, JCA Airedale an overview 25,000m 2 UK premier test centre 450 staff Global distribution A Modine company Modine centre of excellence Airedale
High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.
High Density Data Centers Fraught with Peril Richard A. Greco, Principal EYP Mission Critical Facilities, Inc. Microprocessors Trends Reprinted with the permission of The Uptime Institute from a white
Data Center Components Overview
Data Center Components Overview Power Power Outside Transformer Takes grid power and transforms it from 113KV to 480V Utility (grid) power Supply of high voltage power to the Data Center Electrical Room
Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001
Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001 Presented by: Liberty Engineering, LLP 1609 Connecticut Avenue
Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings
WHITE PAPER Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings By Lars Strong, P.E., Upsite Technologies, Inc. Kenneth G. Brill, Upsite Technologies, Inc. 505.798.0200
QUALITATIVE ANALYSIS OF COOLING ARCHITECTURES FOR DATA CENTERS
WHITE PAPER #30 QUALITATIVE ANALYSIS OF COOLING ARCHITECTURES FOR DATA CENTERS EDITOR: Bob Blough, Emerson Network Power CONTRIBUTORS: John Bean, APC by Schneider Electric Robb Jones, Chatsworth Products
Creating Data Center Efficiencies Using Closed-Loop Design Brent Goren, Data Center Consultant
RESEARCH UNDERWRITER WHITE PAPER LEAN, CLEAN & GREEN Wright Line Creating Data Center Efficiencies Using Closed-Loop Design Brent Goren, Data Center Consultant Currently 60 percent of the cool air that
Center Thermal Management Can Live Together
Network Management age e and Data Center Thermal Management Can Live Together Ian Seaton Chatsworth Products, Inc. Benefits of Hot Air Isolation 1. Eliminates reliance on thermostat 2. Eliminates hot spots
Hot Air Isolation Cools High-Density Data Centers By: Ian Seaton, Technology Marketing Manager, Chatsworth Products, Inc.
Business Management Magazine Winter 2008 Hot Air Isolation Cools High-Density Data Centers By: Ian Seaton, Technology Marketing Manager, Chatsworth Products, Inc. Contrary to some beliefs, air is quite
Data Centers. Mapping Cisco Nexus, Catalyst, and MDS Logical Architectures into PANDUIT Physical Layer Infrastructure Solutions
Data Centers Mapping Cisco Nexus, Catalyst, and MDS Logical Architectures into PANDUIT Physical Layer Infrastructure Solutions 1 Introduction The growing speed and footprint of data centers is challenging
White Paper Rack climate control in data centres
White Paper Rack climate control in data centres Contents Contents...2 List of illustrations... 3 Executive summary...4 Introduction...5 Objectives and requirements...6 Room climate control with the CRAC
Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc. [email protected]
Minneapolis Symposium September 30 th, 2015 Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc. [email protected] Learning Objectives 1. Gain familiarity with Computational
How Row-based Data Center Cooling Works
How Row-based Data Center Cooling Works White Paper 208 Revision 0 by Paul Lin and Victor Avelar Executive summary Row-based data center cooling is normally regarded as a cold air supply architecture that
Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity
Liebert Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment Precision Cooling For Business-Critical Continuity The Intelligent Data Center Cooling Solution: Liebert Trust the industry
Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER
Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER Lylette Macdonald, RCDD Legrand Ortronics BICSI Baltimore 2011 Agenda: Discuss passive thermal management at the Rack
Elements of Energy Efficiency in Data Centre Cooling Architecture
Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total
GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.
GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp. Overview Data centers are an ever growing part of our economy.
Data Center Cooling & Air Flow Management. Arnold Murphy, CDCEP, CDCAP March 3, 2015
Data Center Cooling & Air Flow Management Arnold Murphy, CDCEP, CDCAP March 3, 2015 Strategic Clean Technology Inc Focus on improving cooling and air flow management to achieve energy cost savings and
The New Data Center Cooling Paradigm The Tiered Approach
Product Footprint - Heat Density Trends The New Data Center Cooling Paradigm The Tiered Approach Lennart Ståhl Amdahl, Cisco, Compaq, Cray, Dell, EMC, HP, IBM, Intel, Lucent, Motorola, Nokia, Nortel, Sun,
Greening Commercial Data Centres
Greening Commercial Data Centres Fresh air cooling giving a PUE of 1.2 in a colocation environment Greater efficiency and greater resilience Adjustable Overhead Supply allows variation in rack cooling
Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings
WHITE PAPER Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings By Kenneth G. Brill, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies, Inc. 505.798.0200
IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS
IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS SUMMARY As computer manufacturers pack more and more processing power into smaller packages, the challenge of data center
Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling
Data Center Design Guide featuring Water-Side Economizer Solutions with Dynamic Economizer Cooling Presenter: Jason Koo, P.Eng Sr. Field Applications Engineer STULZ Air Technology Systems jkoo@stulz ats.com
Benefits of. Air Flow Management. Data Center
Benefits of Passive Air Flow Management in the Data Center Learning Objectives At the end of this program, participants will be able to: Readily identify if opportunities i where networking equipment
Power and Cooling Guidelines for Deploying IT in Colocation Data Centers
Power and Cooling Guidelines for Deploying IT in Colocation Data Centers White Paper 173 Revision 0 by Paul Lin and Victor Avelar Executive summary Some prospective colocation data center tenants view
Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION
Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION The heat load in data centers is increasing rapidly, the adaptation of a cooling strategy is often necessary. Many data centers and server rooms use
Enclosure and Airflow Management Solution
Enclosure and Airflow Management Solution CFD Analysis Report Des Plaines, Illinois December 22, 2013 Matt Koukl- DECP Mission Critical Systems Affiliated Engineers, Inc. Contents Executive Summary...
Re-examining the Suitability of the Raised Floor for Data Center Applications
Re-examining the Suitability of the Raised Floor for Data Center Applications By Neil Rasmussen White Paper #19 Revision 1 Executive Summary The circumstances that gave rise to the development and use
EHDC. Cooling system for Data Center and server cabinets.
EHDC Cooling system for Data Center and server cabinets. EHDC PEN LP EHDC L is a High Density Cooling module for an pen Loop configuration. It is ideally installed with Enoc Systems cold corridor containment
Access Floor Solutions
Access Floor Solutions Product Guide SustainAbility to the Power of Developer/Built-to-Suit: KDC Development, AAA Customer Contact Center, Oklahoma City, OK, 150,000 ft 2 High Performance and Sustainable:
Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency
Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency A White Paper from the Experts in Business-Critical Continuity TM Executive Summary As electricity prices and IT
Improving Data Center Energy Efficiency Through Environmental Optimization
Improving Data Center Energy Efficiency Through Environmental Optimization How Fine-Tuning Humidity, Airflows, and Temperature Dramatically Cuts Cooling Costs William Seeber Stephen Seeber Mid Atlantic
How To Improve Energy Efficiency In A Data Center
Google s Green Data Centers: Network POP Case Study Table of Contents Introduction... 2 Best practices: Measuring. performance, optimizing air flow,. and turning up the thermostat... 2...Best Practice
Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM
Data Center Rack Systems Key to Business-Critical Continuity A White Paper from the Experts in Business-Critical Continuity TM Executive Summary At one time, data center rack enclosures and related equipment
Blade Servers and Beyond: Adaptive Cooling for the Next Generation of IT Systems. A White Paper from the Experts in Business-Critical Continuity
Blade Servers and Beyond: Adaptive Cooling for the Next Generation of IT Systems A White Paper from the Experts in Business-Critical Continuity Executive Summary In enterprise data centers, designers face
AIR-SITE GROUP. White Paper. Green Equipment Room Practices
AIR-SITE GROUP White Paper Green Equipment Room Practices www.air-site.com Common practices to build a green equipment room 1 Introduction Air-Site (www.air-site.com) is a leading international provider
Scalable. Affordable. Flexible. Fast.
Modular Data Center Solutions Scalable. Affordable. Flexible. Fast. Build the data center you need today with the flexibility to meet tomorrow s challenges The only constant in business is change. Fluctuations
Green Data Centre Design
Green Data Centre Design A Holistic Approach Stantec Consulting Ltd. Aleks Milojkovic, P.Eng., RCDD, LEED AP Tommy Chiu, EIT, RCDD, LEED AP STANDARDS ENERGY EQUIPMENT MATERIALS EXAMPLES CONCLUSION STANDARDS
BRUNS-PAK Presents MARK S. EVANKO, Principal
BRUNS-PAK Presents MARK S. EVANKO, Principal Data Centers of the Future and the Impact of High Density Computing on Facility Infrastructures - Trends, Air-Flow, Green/LEED, Cost, and Schedule Considerations
Cabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
Energy and Cost Analysis of Rittal Corporation Liquid Cooled Package
Energy and Cost Analysis of Rittal Corporation Liquid Cooled Package Munther Salim, Ph.D. Yury Lui, PE, CEM, LEED AP eyp mission critical facilities, 200 west adams street, suite 2750, Chicago, il 60606
GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group
GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY Public Sector ICT Special Working Group SERVER ROOM ENERGY EFFICIENCY This guide is one of a suite of documents that aims to provide guidance on ICT energy efficiency.
HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE
HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE Best practices for airflow management and cooling optimisation AIRFLOW MANAGEMENT COLD AND HOT AISLE CONTAINMENT DC ASSESSMENT SERVICES Achieving true 24/7/365
EMC DURHAM CLOUD DATA CENTER
EMC DURHAM CLOUD DATA CENTER Energy efficient design and construction EMC IT was hard at work reducing operational costs, increasing IT agility, and preparing for a dynamic future in the cloud when it
Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360
Autodesk Revit 2013 Autodesk BIM 360 Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360 Data centers consume approximately 200 terawatt hours of energy
Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
Reducing the Annual Cost of a Telecommunications Data Center
Applied Math Modeling White Paper Reducing the Annual Cost of a Telecommunications Data Center By Paul Bemis and Liz Marshall, Applied Math Modeling Inc., Concord, NH March, 2011 Introduction The facilities
2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms
Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms Agenda Review of cooling challenge and strategies Solutions to deal with wiring closet cooling Opportunity and value Power
Small Data / Telecommunications Room on Slab Floor
Small Data / Telecommunications Room on Slab Floor Small Data / Telecommunications Room on Slab Floor During a warm summer period in 2008, Great Lakes experienced a network outage due to a switch failure
Benefits of Cold Aisle Containment During Cooling Failure
Benefits of Cold Aisle Containment During Cooling Failure Introduction Data centers are mission-critical facilities that require constant operation because they are at the core of the customer-business
News in Data Center Cooling
News in Data Center Cooling Wednesday, 8th May 2013, 16:00h Benjamin Petschke, Director Export - Products Stulz GmbH News in Data Center Cooling Almost any News in Data Center Cooling is about increase
Blade Server & Data Room Cooling Specialists
SURVEY I DESIGN I MANUFACTURE I INSTALL I COMMISSION I SERVICE SERVERCOOL An Eaton-Williams Group Brand Blade Server & Data Room Cooling Specialists Manufactured in the UK SERVERCOOL Cooling IT Cooling
How To Improve Energy Efficiency Through Raising Inlet Temperatures
Data Center Operating Cost Savings Realized by Air Flow Management and Increased Rack Inlet Temperatures William Seeber Stephen Seeber Mid Atlantic Infrared Services, Inc. 5309 Mohican Road Bethesda, MD
abstract about the GREEn GRiD
Guidelines for Energy-Efficient Datacenters february 16, 2007 white paper 1 Abstract In this paper, The Green Grid provides a framework for improving the energy efficiency of both new and existing datacenters.
Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
Data Center Airflow Management Retrofit
FEDERAL ENERGY MANAGEMENT PROGRAM Data Center Airflow Management Retrofit Technology Case Study Bulletin: September 2010 Figure 1 Figure 2 Figure 1: Data center CFD model of return airflow short circuit
Data Center Energy Profiler Questions Checklist
Data Center Energy Profiler Questions Checklist Step 1 Case Name Date Center Company State/Region County Floor Area Data Center Space Floor Area Non Data Center Space Floor Area Data Center Support Space
Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert
Data Center Consolidation Trends & Solutions Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert Agenda Traditional Data Centers Drivers of a Changing Environment Alternate
Energy-efficient & scalable data center infrastructure design
Seminar am 30. September 2010 in Wetzlar Nachhaltigkeit durch UPI (Unified Physical Infrastructure) Vortrag von Stefan Fammler: Energieeffiziente Strategien im Rechenzentrum Energy-efficient & scalable
Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks
Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same
White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010
White Paper Data Center Containment Cooling Strategies WHITE PAPER EC9001 Geist Updated August 2010 Abstract Deployment of high density IT equipment into data center infrastructure is now a common occurrence
Data Center Trend: Distributed Power in the White Space
Data Center Trend: Distributed Power in the White Space By Jason Anderson Product Line Manager Eaton Executive summary Cloud computing vendors and colocation data centers make every effort to maximize