DOUBLE-ADHESIVE VAPOUR BARRIER

Similar documents
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Polymeric membrane for roof waterproofing

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

POLYGLASS ROOF WATERPROOFING MEMBRANES POLYSHIELD ROOF WATERPROOFING MEMBRANES

DENSO WATERPROOFING SYSTEMS

BAUDER BITUMINOUS ROOFING SYSTEMS BAUDERFLEX ROOF WATERPROOFING SYSTEMS

Please read the entire document before purchasing and installing any of these products

TECHNOELAST ROOF WATERPROOFING MEMBRANES TECHNOELAST APP EPP AND TECHNOELAST APP EKP ROOF WATERPROOFING MEMBRANES

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November l Water and water vapour barrier. l Factory controlled thickness

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

Peel & Seal Self-Stick Roofing Solutions

Regulations Detail Sheet 1

synthetic waterproofing systems

AND MEMBRANES ROOFING UNDERLAYS.

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

Double Coated Urethane Foam Tapes

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

Technology at its best. Benefits

Fosroc Proofex Engage

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

AXTER ROOF WATERPROOFING MEMBRANES EXCEL ROOF SYSTEM

Asphalt Shingle Application Requirements

SEAMS SEAMING USING SEAM TAPE

RHEPANOL RHEPANOL FK ROOF COVERING SYSTEM

CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application

Use, maintenance and inspection of waterproof roofing systems. Polymer-Modified Distilled Bitumen Membranes

Membrane Roofing. Advances in Membrane Roofing

Multi-layer Insulation Blanket for Roofs

ALUMASC ROOF WATERPROOFING MEMBRANES EUROROOF MASTERGOLD ROOF WATERPROOFING MEMBRANE

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Herringbone Pattern Flooring

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Prefabricated building PVC vertical sliding window

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick

BLACK JACK ALL WEATHER ROOF COATING

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING General Materials Equipment...

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Specialist vapour diffusion torch-on membrane Wentylacyjny Werner PYE PV250 S54 is used to make new roofs as well as renovate old ones.

LANGLEY S ROOF WATERPROOFING MEMBRANES PARADIENE/PARAFOR ROOF WATERPROOFING SYSTEMS

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES

BBA BRITISH. tanking. Application. Storage & Handling

SHINGLE APPLICATION GUIDE

FATRA ROOF COVERING SYSTEMS FATRAFOL FF807 AND FATRAFOL FF807/V ROOF COVERING SYSTEMS

CHAPTER 7: Building Systems ROOFING SYSTEMS

Including. Rubershield-Pro. Breather Membrane

08 Visqueen Zedex cpt Dpc 12 Visqueen Zedex High bond Dpc 14 Visqueen preformed unit

Colorado State University. Durrell Center Roof Repair

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

RECOATING AND RENEWING SPF ROOFING SYSTEMS

The assessment is described in the following pages which form integral parts of this certificate, which should be read in its entirety.

Casali SpA Industria Chimica Bituminosa

ROOFING PRODUCTS. INSTALLATION GUIDE FOR RESISTO. Time-tested premium quality products

CHAPTER 6 ASPHALT ROLL ROOFING

Ubiflex. Non-lead flashing system

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

ICOPAL POUR AND ROLL ROOF WATERPROOFING ICOPAL POWER ELASTOMERIC ROOF WATERPROOFING SYSTEM

COATING & WRAPPING OF UNDERGROUND PIPING

Elastic, 1-part-polyurethane, liquid waterproofing membrane

GENERAL RUBBER LINING PRINCIPLES

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Mezzanine. Technical manual

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

SIKA TANKING MEMBRANES SIKAPROOF A MEMBRANES

SikaProof A Technology

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

Gas Membrane and Waterproof Tanking Systems

European Technical Approval ETA 12/0419

SARNAFIL WATERPROOFING MEMBRANES SARNAFIL ADHERED ROOF WATERPROOFING MEMBRANES

Building Owners Guide to a Duro-Last System!

Preprufe 160 Sheet Tanking and Waterproofing Membrane

How To Test A Wrap N Drain X Dampproofing System

ROOFERS CHOICE BREATHER MEMBRANES FOR USE IN COLD NON-VENTILATED ROOFS

Roofing Systems. New Applications / Re-Roofing / Maintenance

SANS FIRE PERFORMANCE SANS 428 ENERGY SAVER REFLECTIVE TIASA A MEMBER OF 2009/ / / /341

DE BOER WATERPROOFING MEMBRANES

Sun-Activ - reflective SBS membrane. Sun-Activ - White reflective bituminous waterproofing membrane for Cool Roof

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

WATERPROOFING OF WET ROOMS

COMMERCIAL BUILDING APPLICATIONS

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

Self-Stick Roofing Solutions

12.1 Schlüter -KERDI-BOARD

Ground Gas Barriers.

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

Transcription:

The leader in the selfadhesive technology! POLYVAP SA DOUBLE-ADHESIVE VAPOUR BARRIER ALUMINIUM FOIL POLYVAP SA is a high quality double-adhesive bituminous membrane made with ADESO technology, indicated for use beneath thermoplastic thermal insulation. LATEST GENERATION SELF-ADHESIVE MEMBRANES Guaranteed Quality UNI EN ISO 9001:2008 and UNI EN ISO 14001:2004 Products in compliance with European standards Polyglass is a member of Green Building Council Bituminous membrane polymeric matrix ageing control Incredible lightweight Without mechanical fixings All year membranes No flame (greater work site safety) Odour free Easy to apply IDEAL ON INSULATION PANELS SENSITIVE TO FLAME

TECHNICAL DESCRIPTION POLYVAP SA is a high quality double-adhesive bituminous membrane made with ADESO technology, the new compound layering system from Polyglass SpA. POLYVAP SA is made from a special elastomeric (SBS) self-adhesive compound reinforced with an aluminium foil. This reinforcement allows the product an excellent dimensional stability, good mechanical characteristics, a complete vapour barrier and excellent on-site capability. POLYVAP SA has both sides protected by a mono-silicone coated polyethylene film which is removed when the membrane is applied. Granule-free end-lap Self-adhesive end-lap. Lateral adhesive overlap APP or SBS Waterproofing compound Reinforcement SELF-ADHESIVE Compound Removable monosiliconized film INTENDED USE AS PER CE STANDARDS SINGLE LAYER MULTI-LAYER ROOT BARRIER VAPOUR BARRIER FOUNDATIONS PRODUCT F.L. S. R.D. G. V. U.H.P. V. U.H.P. V. U.H.P. 2 mm F.L.: Finishing Layer - S.: Substrate - R.H.: Rising Damp - G.: Groundwater - V.: Visible - U.H.P.: Under Heavy Protection UNDER DISCONTINUOUS ROOFING POLYVAP SA is indicated for use beneath thermoplastic thermal insulation materials, such as polyurethane foam, extruded and foam polystyrene, etc. wood roofs, and wherever flaming cannot be used for application.

APPLICATION: INSTRUCTIONS AND RECOMMENDATIONS Unroll POLYVAP SA making sure that the adhesive part is facing down. Remove half of the mono-silicone coated release film at the lower end of the roll, fasten the sheet, and then remove the other half of the film, taking care to avoid the formation of air bubbles or wrinkles. When laying on a pitched roof, the apply the rolls from upwards downwards. At the roof s ridge line, the membrane must be folded back 20-30 cm and then fastened mechanically. Whenever roof pitch is greater than 30%, the membrane must be fastened mechanically also at the overlap points (in accordance with the UNI reference standards), in order to avoid slipping and contrast the action of the wind. Make sure that any nails are completely covered by the next layer s selvedge strip. Extra attention must be paid to the overlapping of the sheets. We recommend using shears, tile cutters, pressing rollers and leister hot air guns. The surfaces to be waterproofed must be dry, clean, and provided with a coat of bituminous primer. The excessive humidity of the surfaces to be waterproofed can cause the detachment of the membrane and the formation of blisters. The product must never be laid at temperatures of less than 5 C and always only in good weather. POLYVAP SA must never be exposed to inclement weather. Correct positioning of the vapour barrier STOCKING Keep the products packed in the carton box in a dry place, away from direct sunlight. Do not place the pallets, one on top of another and the rolls must always be stocked in a vertical position. The contact with solvents and organic liquids may damage the product. Avoid application if the temperature is excessively low or high, avoid stamping (shoes with crampons, small objects or sharp edges). For further information contact Polyglass SpA Technical Office. POLYVAP SA Keep out of direct sunlight. DIMENSIONS PACKAGING PRODUCT Avoid stocking pallets without evenly distributing the load. Keep the rolls standing. THICKNESS mm WEIGHT kg/m 2 Absolutely avoid puncturing the product. DIMENSIONS m POLYVAP SA 2-1x15

TECHNICAL SPECIFICATIONS TEST METHOD TECHNICAL SPECIFICATIONS UNIT OF MEASURE NOMINAL VALUES EN 1848-1 LENGTH m 15 EN 1848-1 WIDTH m 1 EN 1848-1 STRAIGHTNESS mm/10 m Exceeds EN 1849-1 THICKNESS mm 2 (±0,2) EN 1849-1 MASS PER UNIT AREA kg/m 2 NPD EN 1928-B WATERTIGHTNESS kpa Exceeds EN 13501-1 REACTION TO FIRE Euroclass E EN 12317 SHEAR RESISTANCE N/50 mm 400/150 (-20%) TENSILE PROPERTIES EN 12311-1 MAXIMUM LOAD AT BREAK Longitudinal Transversal ELONGATION AT BREAK Longitudinal Transversal N/50 mm N/50 mm 500 (-20%) 200 (-20%) % % 4 (-2) 4 (-2) EN 12691-A RESISTANCE TO IMPACT mm 600 RESISTANCE TO TEARING EN 12310-1 Longitudinal N Transversal N 100 (-30%) 100 (-30%) EN 1109 COLD FLEXIBILITY C -25 EN 1931 WATER VAPOUR PROPERTIES μ 700000 (±30%) EN 1847 EN 1931 WATER VAPOUR TRANSMISSION PROPERTIES AFTER EXPOSURE TO CHEMICALS WATER VAPOUR TRANSMISSION PROPERTIES AFTER THERMAL AGEING kpa POLYVAP SA EN 1296 EN 1931 μ EN 1850-1 VISIBLE DEFECTS - ABSENT ASTM D 1000 PEELING N/10 mm 20 Thickness and weight parameters are indicative only for Italian market. In compliance with EN 13970 products standards (vapour barrier). ±50% initial value ±50% initial value NOMINAL VALUES Considering the various situations of use, the numerous types of support surfaces and the possibilities for use inside COMPLEX WATERPROOF LAYERING, Polyglass SpA cannot assume any liability for damages derived from the product s results in terms of function or aesthetics.

APPLICATION METHOD 300 gr/m 2 4 5 6 7 8 9 10 11 12 1 Treat the surface to be waterproofed with bituminous primer (POLYPRIMER HP 45 Professional). 2 Remove the roll from the package. 3 Lay and align the sheet up to a certain reference point (perimeter wall, gutter line, etc.). 4 Remove the first half of the mono-silicone coated film. 5 Fold the sheet back halfway lengthwise and remove the second half of the mono-silicone coated film. 6 Apply the next layers in the same way. 7 Roll over the areas in which the sheets overlap. 8 Remove the mono-silicone coated film on the top surface. 9 / 10 Position the insulation panels. 11 / 12 Apply the self-adhesive waterproofing membrane over the insulation system.

POLYGLASS SPA reserves the right to modify the products, without notice, in any necessary way in order to guarantee the continuous improvement of the product. www.polyglass.com 05/14 POLYGLASS SPA Registered Office: Viale Jenner, 4-20159 MILANO Head Office: Via dell Artigianato, 34-31047 Ponte di Piave (TV) - Italy Tel. +39 04227547 - Fax +39 0422854118 - www.polyglass.com - info@polyglass.it