Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
|
|
|
- Preston Haynes
- 10 years ago
- Views:
Transcription
1 Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02
2 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice for protection of structures against water from the ground, gives three categories of waterproofing for a basement: Tanking A continuous waterproof barrier is applied to the inside or outside of the basement structure. Structurally integral protection Usually water resistant concrete in combination with a waterproof membrane Drained cavity Cavities are formed within the walls and floor to collect and drain away water entering the basement. Heat loss The pattern of heat loss from a basement wall is complex, with the rate of heat loss diminishing as the depth of the basement increases. This is due to the insulation value of the ground behind the basement wall. A method for calculating U-values for basements is given in BS EN ISO: Position of insulation Installing rigid insulation externally is the preferred method for insulating new basement walls. Key 1. Externally insulated External insulation is the preferred option for basements as the whole structure is kept warm, with negligible risk of condensation. The insulation should be placed up against the waterproofing membrane. Polyfoam ECO (extruded polystyrene) is recommended because it has negligible moisture absorption and high compression resistance. A drainage membrane or layer of washed no fines gravel should be placed adjacent to the insulation. This relieves hydrostatic pressure and channels water to the foundation drain. The membrane or gravel should be covered with a geotextile to prevent fines from blocking the drainage material. 2. Internally insulated Internal insulation of basement walls is only recommended for existing basements where it is not possible to insulate the basement externally. New basements should be insulated externally. Any insulation system applied to the interior of the basement should have the following properties: It must allow the basement wall to dry out to the inside, for example by means of a cavity drainage system It must prevent warm moist air reaching the cold basement wall and condensing. A vapour control layer (vcl) should always be installed on the warm side of the insulation to prevent water vapour from the basement rooms condensing on the cold cavity drainage system. All joints, tears, overlaps and perforations in the vcl should be well sealed with an aluminised tape. Materials in contact with the basement wall and floor must be moisture tolerant, like, a closed cell extruded polystyrene board that is unaffected by moisture. The detail opposite shows a solution for an existing basement with solid brick walls, there is a drained cavity system directly behind the wall which drains to a sump. Other considerations The land around the building should slope away from the basement walls. Ideally the area adjacent to the building should have an impermeable finish, such as concrete paving. For new basements, a drain should be located around the perimeter of the basement and positioned at least 200mm below the finished level of the basement floor. It should be bedded and surrounded in free draining aggregate and wrapped in a geotextile before backfilling, to prevent fines from blocking the drain. Thermal insulation achievable by constructions within this document. Pb01 Find online. Visit knaufinsulation.co.uk and key in construction code to find the most up to date information on your chosen solution. Knauf Insulation solution U-values Wall insulated externally Product: Standard or Extra See page: 260 Ba01 Wall insulated internally Product: Standard or Extra See page: 262 Ba Technical Advice and Support Centre
3 Basements 1. Externally insulated basement walls Ground to slope away from wall and have impermeable finish wherever possible Basement and wall insulation to overlap Concrete block retaining wall with reinforced poured concrete infill Waterproofing membrane Cavity drainage membrane or use free-draining backfill below screed Geotextile membrane Perforated pipe as foundation drain, 200mm below basement floor, with coarse gravel surround 2. Internally insulated basement walls Continuity insulation with joints taped and sealant applied to junctions with surrounding structure Top of cavity drainage membrane sealed to prevent moisture escaping Plasterboard on timber or steel frame allows services to be installed Ground to slope away from wall and have impermeable finish wherever possible Existing basement wall Vapour control layer on the face of the insulation Cavity drainage membrane directs water from basement wall to sump in floor Technical Advice and Support Centre
4 Basements Basements Wall insulated externally Moisture resistant - long term exposure to water has a negligible impact on thermal performance Robust product, protects the waterproofing layer from damage High compressive strength, withstands the pressure exerted by the backfill Ba01 NEW BUILD Zero Ozone Depletion Potential (ODP) Global Warming Potential (GWP) <5 Geotextile membrane around drainage at base of wall Drainage channel membrane Basement wall Waterproof membrane Products s are rigid extruded polystyrene boards, they are lightweight, yet have excellent structural strength and long term effectiveness. Standard and Extra are suitable for the external insulation of basement walls. Typical construction Masonry or in-situ concrete basement walls (up to 2.5m deep) insulated with Polyfoam ECO Standard placed against the tanking membrane. For basements between 2.5m and 5m deep, Extra is recommended for its greater compressive strength. The basement wall insulation is protected by a drainage cavity membrane which also reduces hydrostatic pressure and directs water to the foundation drain. Installation s are placed against the tanking membrane and protected by a drainage cavity membrane. Carefully backfill with free-draining granular material to hold the drainage cavity membrane and insulation in place. Where s project above the ground they should be covered by a reflective or light coloured flashing board, or similar, to prevent long term exposure of the insulation to Ultra Violet (UV) light. Performance Thermal insulation Standard and Extra have a thermal conductivity of W/mK. 260 Technical Advice and Support Centre
5 Basements Junction of basement and external wall Cavity wall insulation Cavity tray Minimum 150mm overlap between wall and basement insulation to minimise thermal bridging Typical specification Install Standard*/ Extra*,...mm thick, against the tanking membrane. Cover with a drainage cavity membrane, manufactured by... and carefully backfill to hold the insulation in place. (*delete as appropriate) Alternatively, consult the National Building Specifications, Standard version clause/ clauses M21/210 Knauf Insulation specification clauses can be downloaded from knaufinsulation.co.uk/nbs Drainage channel membrane Reinforced concrete infill to engineer s design Waterproof membrane Compression resistance s are highly resistant to compression and are capable of withstanding both occasional and long term high static loads. Load bearing construction elements should be designed to adequately support the combination of imposed and dead loads without creating excessive deflection. Table 1 - Typical U-values for basement walls insulated externally Thickness (mm) U-values (W/m 2 K) for basement depth (m) of: Standard n/a n/a n/a n/a Moisture resistance s have negligible water absorption and are unaffected by standing in ground water. Fire performance In the construction detailed above, Polyfoam ECO s are completely enclosed by other materials and will not contribute to the development stages of a fire or present a smoke or toxic hazard n/a n/a n/a n/a n/a n/a Extra 75 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Notes: The calculations assume that the basement floor has a U-value of 0.25 W/m 2 K. CERTIFICATE CS/ U Value Competency Scheme Technical Advice and Support Centre
6 Basements Basements Wall insulated internally Polyfoam 04/4186 Versatile product, can be used to insulate both walls and floors High compressive strength accommodates the loads associated with the fit out of the basement Ba02 Vapour control layer Plasterboard Independent frame REFURB Robust and lightweight, making it easy to cut and handle on site Existing basement wall Polyfoam ECO Standard BBA certified (floors) Zero Ozone Depletion Potential (ODP) Global Warming Potential (GWP) <5 Screed Slip layer Polyfoam ECO Cavity drainage membrane Products Standard is a rigid extruded polystyrene board, it is lightweight, yet has excellent structural strength and long term effectiveness. Standard is suitable for the internal insulation of basement walls. Typical Construction Existing solid masonry basement wall with new cavity drainage membrane, Polyfoam ECO Standard insulation and Knauf I stud independent lining. This system is most suitable for existing basement walls. The cavity drainage membrane collects any water that passes through the basement wall and drains it to a sump, from where it is pumped to a drain. The internal lining allows services to be accommodated. Installation Standard is fixed to the cavity drainage membrane using a nonsolvent based adhesive such as plaster adhesive. Ensure the floor and wall insulation are in intimate contact with each other and all joints fully closed. Install a vapour control layer on the warm side of the insulation. The vapour control layer should be free from holes and any gaps should be made good with tears repaired and overlaps sealed with aluminised tape. The wall vapour control layer should be sealed to the slip layer placed below the screed. After the floor slab or screed has been laid, construct the Knauf I stud lining and line the steel studwork with plasterboard. 262 Technical Advice and Support Centre
7 Basements Sump in basement floor Vapour control layer Discharge pipe to outside Inspection cover Sump pump Cavity drainage membrane drains into sump Typical specification Standard...mm thick, to be fixed directly against the drainage cavity membrane, with dabs of plaster adhesive. Tape all joints with an aluminium faced self-adhesive tape. Seal the junction between the Polyfoam ECO Standard and the surrounding construction with a water resistant, solvent free silicone sealant. Alternatively, consult the National Building Specifications, Standard version clause/clauses M10/40 or M10/290 Knauf Insulation specification clauses can be downloaded from knaufinsulation.co.uk/nbs Performance Thermal performance Standard has a thermal conductivity of W/mK. Compression resistance Standard is highly resistant to compression and withstands both occasional and long term static loads. Load bearing construction elements should be designed to adequately support the combination of imposed and dead loads without creating excessive deflection. Table 2 - Typical U-values for basement walls insulated internally Thickness (mm) U-values (W/m 2 K) for basement depth (m) of: Standard Notes: The calculations assume that the basement floor has a U-value of 0.25 W/m 2 K. Moisture resistance Standard has negligible water absorption and is unaffected by standing in ground water. Fire performance In the construction shown above, Polyfoam ECO Standard is completely enclosed by other materials and will not contribute to the development stages of a fire or present a smoke or toxic hazard. CERTIFICATE CS/ U Value Competency Scheme Table 3 - Compressive creep results for Polyfoam s Product Polyfoam ECO Standard Load applied (kpa) Initial compression (%) Further compression after 50 years (%) Technical Advice and Support Centre
8 Knauf Insulation Ltd Customer Service (Sales) Technical Advice and Support Centre Literature PO Box 10 Tel: Tel: Tel: Stafford Road Fax: Fax: Fax: St Helens Merseyside WA10 3NS
Section 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane
Section Flat Roofs Warm deck single ply membrane Product: Rocksilk Krimpact Flat Roof Slab Fl01 Warm deck single ply membrane Product: Polyfoam ECO Roofboard Fl02 Warm deck built-up felt/ mastic asphalt
Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining
Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02
Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01
Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal
Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with
Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and
Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
Basements. I n s u l a t i o n. Low Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (13.9) Rn7 M2 Third Issue March 2011 INSULATION FOR BASEMENTS Basements High performance rigid extruded polystyrene insulation thermal conductivities as low as 0.029 W/m.K High
Renovating Your Basement
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:
Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5
Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,
Rockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
Basement Moisture Problems
Foundations Foundation Purpose The purpose of a foundation is to distribute the weight of a structure securely into the ground. Engineering data regarding soil, rock and water conditions are used to design
What you need to know about concrete block basement construction.
Designing and planning your new residence is a vitally important process, which will have a great influence on the future enjoyment of your home. A successful process will ensure all areas of the home
The Kingspan Insulation Price List 1 st January 2013
Insulation The Kingspan Insulation Price List 1 st January 2013 FOR BUILDING FABRIC INSULATION, CAVITY CLOSERS AND MEMBRANES Visit our website: www.kingspaninsulation.co.uk Low Energy - Low Carbon Buildings
Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37
Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM
P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer
Simplifying design and construction. Alan Tovey, Director The Basement Information Centre
Simplifying design and construction Alan Tovey, Director The Basement Information Centre Simplifying design and construction Grades of construction Construction options Design and waterproofing issues
Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008. Foundation Heave Protection
Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008 Foundation Heave Protection The safe, sure way to provide foundation protection Clayshield is the proven solution to protecting foundations against
ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R00060057. Lecturer: Jim Cahill
ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R00060057 Lecturer: Jim Cahill 29 th November 2011 TABLE OF CONTENTS SUMMARY 1 MAIN BODY SECTION
September 2007. September 2013. Consulting Structural and Civil Engineers. 100 St John Street London EC1M 4EH. info @ akt-uk.com www.akt-uk.
Consulting Structural and Civil Engineers 100 St John Street London EC1M 4EH T +44 (0) 20 7250 7777 F +44 (0) 20 7250 7555 info @ akt-uk.com www.akt-uk.com 3290 A031234 The 196-222 Joseph Kings Bloggs
Timber Frame Walls Rethinking Construction
Insulation Fifth Issue November 2007 Timber Frame Walls Rethinking Construction INSULATION BEST PRACTICE FOR THE 21ST CENTURY Summary 9 mm OSB sheathing 3 mm skim coated 15 mm plasterboard Rock or glass
Multi-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof
EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES
Building and Construction Industry A joint industry initiative produced by BSA Supershow logo.indd 1 30/01/2008 9:43:29 AM EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES FAILING WATERPROOFING
Rockwool Cladding Roll
Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F
Comment Form on Proposed Gut Rehabilitation Alternatives
Comment Form on Gut Rehabilitation Alternatives Name: Organization: Email: Instructions Submission: Please submit this form to [email protected] by October 10 th, 2012 with the subject line
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors
Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes
Waterproofing Solutions
Waterproofing Solutions The Complete Waterproofing Solution Timberwise - working together Far more than just a supplier of basement waterproofing solutions, Timberwise are your professional business partner.
Safeguard Waterproofing Systems. Creating useable. living space. by making basements dry
Safeguard Waterproofing Systems living space Creating useable by making basements dry The SWS waterproof cement system The Safeguard SWS Structural Waterproofing System is designed to be both highly effective
TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Fourth Issue March 2011 TR21 INSULATION FOR FLAT ROOFS WATERPROOFED WITH PARTIALLY BONDED BUILT UP FELT AND MASTIC ASPHALT High performance rigid thermoset insulation
Module 3.7. Thermal bridging
Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal
The Guide To Waterproofing An Existing Basement
The Guide To Waterproofing An Existing Basement John Newton & Company is the leading independent supplier of basement waterproofing and damp proofing solutions in the UK. Newton System 500 is a maintainable
Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure
Basements are Changing John Straube, Ph.D., P.Eng Basements: New & Retrofit Energy Efficient, Durable, Healthy Increasingly used as living space Not a root /coal cellar anymore! High quality space expected
The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A
TechSpecs A builder s blueprint for construction technologies January 2013 The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A C B A E D H G F A. Wood Floor Framing - p. 2 B. Foundation
R E S I D E N T I A L H O U S I N G
HL 252 Rev. April 1997 R E S I D E N T I A L H O U S I N G CONTROLLING EXTERNALWATER PROBLEMS FOR RESIDENCES I II III IV V Lot Drainage Gutter Water Management Foundation Waterproofing Floor Slab Waterproofing
Introduction & Principles Issued in support of Junction Details, Parts 1 to 5
Accredited Construction Details (Scotland) 2010 For the limitation of thermal bridging and air infiltration in low and medium rise domestic buildings Introduction & Principles Issued in support of Junction
State of Connecticut Department of Public Health RADON PROGRAM
State of Connecticut Department of Public Health RADON PROGRAM Scope The Connecticut Department of Public Health (DPH) Radon Program is providing this information for contractors who decide to build radon
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
DELTA Premium Moisture Management Systems for Foundations.
DELTA protects property. Saves energy. Creates comfort. DELTA Premium Moisture Management Systems for Foundations. DELTA Premium Moisture Management Systems provide the best protection for foundations.
SIP (STRUCTURAL INSULATED PANEL)
SIP (STRUCTURAL INSULATED PANEL) KINGSPAN TEK ACORN SIP ABSTRACT BUILDING SERVICES Ltd Kingspan TEK is the manufacturer and supplier of the panels and components. Acorn SIP are the Architects who individually
STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION SOURCES OF MOISTURE IN NEW CONSTRUCTION. Natural ground slope
FOUNDATIONS STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION Build a Better Home Details are critical when constructing a sound building foundation that will withstand water and control dampness.
Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in
REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory
Low Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Eighth Issue March 2011 TR27 LPC/FM INSULATION FOR FLAT ROOFS WATERPROOFED WITH FULLY ADHERED SINGLE PLY, PARTIALLY BONDED BUILT UP FELT, MASTIC ASPHALT AND COLD
Best Practices for Crawl Space Insulation
Best Practices for Crawl Space Insulation Copyright 2011 Basement Systems Inc. All Rights Reserved Table of Contents I - Introduction II - Step By Step Guide 1 - Providing Adequate Drainage 2 - Controling
Basement Waterproofing in Existing Buildings
A S S O C I A T I O N Basement Waterproofing in Existing Buildings A guide to protecting your home Follow us on Twitter Find us on Facebook www.property-care.org A basic understanding of Basement Waterproofing
Waterproofing and interior insulation for basements takes new twist in technology.
Waterproofing and interior insulation for basements takes new twist in technology. Free report reveals how to stop all call backs for basements for the life of the structure by installing these 3 low cost
European Organisation for Technical Approvals
Warrington Certification Limited, Holmesfield Road, Warrington, WA1 2DS Tel. +44 (0) 1925-646777 Fax +44 (0) 1925-646667 Member of EOTA Authorised and notified according to Article 10 of the Council Directive
CHESTERFLEX ROOF WATERPROOFING MEMBRANES
CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED
The Pocket Guide To Insulation August 2013
The Pocket Guide To Insulation August 2013 Introduction Knauf Insulation is the UK s leading manufacturer of insulation products, including: Earthwool glass and rock mineral wool Polyfoam ECO extruded
Ground Gas Barriers. www.tritonsystems.co.uk
Minimum 2 Coats Triton TTVM 0.5l/m² 1st Coat 0.7l/m² 2nd Coat 3 Coats Triton TTVM Incorporating GRM MSSM to Joints Triton Fillet Seal 25mm x 25mm Minimum Construction Joint Ground Gas Barriers n HDPE/PP
Hanson Building Products. precast basement solutions
Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may
Issue of the Guidelines on Prevention of Water Seepage in New Buildings
graphic: Buildings Department Your REF 來 函 檔 號 :. OUR REF 本 處 檔 號 :.BD GR/1-55/173 FAX 圖 文 傳 真 :..28400451 TEL 電 話 :..2626 1717 www.info.gov.hk/bd To : All Authorized Persons 7 March 2005 Registered Structural
Concrete Waterproofing Systems. Integral Protection. www.tritonsystems.co.uk
Concrete Waterproofing Systems Integral Protection n Type B Integral Protection in accordance with BS 8102 (2009) n Unique chemical admix for waterproofing and protection of concrete n A complete and permanent
WET/DAMP BASEMENTS ANSWER: BASEMENT WALLS AND FLOORS CAN BECOME WET BY A LEAK, CAPILLARY SUCTION OR CONDENSATION.
WET/DAMP BASEMENTS PROBLEM. IS THIS BASEMENT LEAKING OR COULD WE HAVE ANOTHER PROBLEM? Water line arching up on wall in corners of basement. Water collecting on concrete floor starting in corners. ANSWER:
The assessment is described in the following pages which form integral parts of this certificate, which should be read in its entirety.
Cl/SfB (13.1) Ly (L2) BRE CERTIFICATION LTD CERTIFICATE OF ASSESSMENT PRODUCT Powerbase RB 340 and RB 370 Radon Resistant Membranes CERTICATE NO. 100/03 ISSUED: MARCH 03 REISSUED: NOVEMBER 07 SUPPLIED
BELL ASSOCIATES ARCHITECTURE PLANNING
BELL ASSOCIATES ARCHITECTURE PLANNING Roger Bell dip. arch. tech. Bsc. CAD Rogerstown, Rush, Co. Dublin. Muchgrange, Greenore, Co. Louth E [email protected] T 01-8430267 T 042 938 3865 M 087 2371984
Manual lifting and handling
Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details
9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES. Hunter Underground Systems
9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES Hunter Underground Systems 9.01 General 9.02 Surface water Drainage 9.03 Groundwater Drainage 9.04 Dispersal of Septic Tank Effluent 9.01 The use of
The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
CHAPTER 6: SUBSTRUCTURE
CHAPTER 6: SUBSTRUCTURE Technical Manual V7: TS-011a-7.00-180814 CHAPTER 6: SUBSTRUCTURE CONTENTS 6.1 BASEMENTS 6.2 WALLS BELOW GROUND 6.3 DAMP PROOFING 6.4 GROUND FLOORS 89 CHAPTER 6 FUNCTIONAL REQUIREMENTS
Low Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Seventh Issue March 2011 TR26 LPC/FM INSULATION FOR FLAT ROOFS WATERPROOFED WITH MECHANICALLY FIXED SINGLE PLY WATERPROOFING High performance rigid thermoset insulation
The Optimum Basement Wall
The Optimum Basement Wall Solutions to the Wet Blanket Basement Problem February 27 th, 2014 1 Adapting to Change! We ve made significant advances in water management. Customers no longer accept that musty
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
Energy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
Design and Construction of Cantilevered Reinforced Concrete Structures
Buildings Department Practice Note for Authorized Persons, Registered Structural Engineers and Registered Geotechnical Engineers APP-68 Design and Construction of Cantilevered Reinforced Concrete Structures
Best Basement Water Management Practices
Best Basement Water Management Practices Guide written by Patrick Sluss Sluss Construction (330) 224 5394 When a home owner is faced with a leaking basement there is a way to correct the problem and a
C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction
C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05 Specialist partitions Introduction Specialist partitions This section details specialist lightweight systems where high-security,
Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA 18000 / Israel. J. Magner Dipl.-Ing. N. Machill.
Kiwa Polymer Institut GmbH Quellenstraße 3 65439 Flörsheim-Wicker Tel. +49 (0)61 45-5 97 10 Fax +49 (0)61 45-5 97 19 www.kiwa.de Test report P 7013-E Testing order: Test of the waterproofing system based
Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org
Rev 1-12.2013 Code of Practice SIP Technology www.uksips.org What are Structural Insulated Panels (SIPS)? SIPS are prefabricated, high performance, lightweight, building panels that can be used in floors,
Built to Last. Built for Beauty. Good. Solid. Logix. TM
Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a
BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.
Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance
Foundation. Foundation
Moisture Aside from structural concerns, the most important consideration for foundation design is moisture. No client wants a wet basement. No client wants a damp basement. No client wants mold in their
Basement Insulation Systems
Basement Insulation Systems The Problem Meeting Energy Star levels of performance is one of the criteria for constructing homes to Building America levels of performance levels defined by the Building
2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
Extra. Technical. November 2014 Issue 16 NHBC STANDARDS GUIDANCE AND GOOD PRACTICE. In this issue:
Technical Extra November 2014 Issue 16 In this issue: NHBC STANDARDS Introducing Chapter 5.4 Waterproofing of basements and other below ground structures page 3 GUIDANCE AND GOOD PRACTICE The basement
Soils, Foundations & Moisture Control
Soils, Foundations & Moisture Control Soil The top loose layer mineral and/or organic material on the surface of the Earth that serves as a natural medium for the growth of plants and support for the foundations
What Causes Foundation Leaking?
A home's foundation has the odds stacked against it from the day it's built. When a home is excavated to make room for the foundation walls, space is left between the outer edge of the foundation wall
Composite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
Presented by Ian Maclennan
DESIGN, LIABILITY AND INTERPRETING STRUCTURAL WATERPROOFING Presented by Ian Maclennan Main ConsideraCons Covered by BS8102 1. Has the waterproofing system been designed by a specialist 2. Has a site inves:ga:on
s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In
Family GUIDE FOR RESIDENTIAL applications Foamular Where quality and performance make a home The OWENS CORNING FOAMULAR XPS INSULATION FAMILY ALBUM is a critical feature of any home impacting overall comfort
Signs of insulation problems In the winter. In the summer. conditioning system
about your house CE 19 While previous generations may have been content to live in drafty houses, most people now want comfortable warm houses. A healthy house today is well sealed, well insulated and
RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November 2013. l Water and water vapour barrier. l Factory controlled thickness
CI/SfB TN6 L6813 November 2013 RIW SHEETSEAL 226 is a cold applied, high density polyethylene film, coated with a bitumen/rubber self adhesive layer with a removable reinforced silicone paper. Primer is
Innovation - High performance roof, wall and floor insulation board. delivering better performance
2010 VERSION 1 IRL High performance roof, wall and floor insulation board Innovation - delivering better performance PRODUCT SPECIFICATION INSTALLATION GUIDE I ve worked with Xtratherm for years, they
CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES
CERTIFICATE OF APPROVAL No CF 5055 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 1 st Industrial Area,
PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection
PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,
plumbing products guide
plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly
Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM
P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 5 Tunnels & Arches V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V Create dry usable space with the original X pattern
Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.
Improving the flood resistance of your home Advice sheet 4: Flood-resilient walls. This sheet provides guidance on identifying different types of wall, and reducing the flow of floodwater through them
Waterproofing membranes are a critical component
Below-Grade Residential: Drainage Boards & Footing Drains Waterproofing membranes are a critical component for keeping basements dry, but they re only half the solution. In most areas of the country, a
Residential Refurbishment. September 2012. ThermoShell Internal Wall Insulation System Design Guide
Residential Refurbishment September 2012 ThermoShell Internal Wall Insulation System Design Guide The importance of wall insulation in houses Buildings account for 40% of our energy consumption and in
MATERIALS. Table 1 Mortar Proportions by Volume (Ref. 12)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY BASEMENT WALL CONSTRUCTION TEK 3- Construction (200) Keywords:
Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description
Product Data Sheet Edition 15/10/2014 Identification no: 02 07 04 10 300 0 000002 SikaProof A Edge SikaProof A-08 Edge, A-12 Edge Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing
FireSmart IRS Insulating Roof Screed
Insulating Roof Screed CI/SfB January 2004 CI/SfB January 2004 M2 P M2 P Icopal Ltd Barton Dock Road Stretford, Manchester M32 0YL Telephone: 0161 865 4444 Fax: 0161 866 9859 Technical Fax: 0161 865 8433
PRESTRESSED CONCRETE FLOORING BEAMS
PRESTRESSED CONCRETE FLOORING BEAMS TRIED & TRUSTED Introduction Established in 2001 TT Concrete Products Limited has become a prominent manufacturer of prestressed concrete flooring beams throughout the
How To Test A Wrap N Drain X Dampproofing System
National Research Council Canada Institute for Research in Construction Conseil national de recherches Canada Institut de recherche en construction CCMC 13094-R &&0& EVALUATION DIVISION 07111 REPORT Issued
Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap
Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet
How To Repair A Boat Landing Deck With A Boat Bed
RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing
This seminar covers the principles, design and installation of ground bearing and suspended insulated floors. You will discover
Dow Construction Products Thermal Insulation of Floors This seminar covers the principles, design and installation of ground bearing and suspended insulated floors. You will discover Why a floor should