Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems
|
|
- Noah Day
- 8 years ago
- Views:
Transcription
1 Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems
2 Introduction A complete range of Memtec Roofing and Waterproofing Single Ply PVC Membranes to suit any type of roof, including all accessories. Memtec BBA certificate holder, number 12/4946 Long life expectancy in excess of 25 years. BBA confirmed. 15 and 20 year product guarantees. Maintenance free. UV resistant. Self extinguishing. Rot proof and high ageing resistance. Root penetration resistant. Thermofusible laps and seams electrically hot air welded without the requirement of dangerous naked flame or hot bitumen. Membranes are mesh reinforced providing maximum dimensional stability both crosswise and lengthwise. Vapour permeable, no blisters. Low temperature pliability minus 25 degrees centigrade without cracks. Can either be mechanically fixed, fully bonded or loose laid and ballasted. Lightweight, fast, clean installation. Excellent aesthetic appearance. Modern efficient performance and cost effective over many years. Special note for home owners of domestic property Single Ply PVC membrane roofing and waterproofing systems have now been employed in the main UK commercial and industrial roofing and waterproofing industry for some 40 years. Millions of square metres have been installed over that period and is part of the main reason for the dramatic decline in the use of old fashioned outdated bituminous felt and asphalt type roof covering systems. MEMTEC Modern efficient performance cost effective flat roofing systems Modern Memtec Single Ply PVC membrane roofing and waterproofing systems are now accessible and available to home owners of domestic property. If you are building a new house, house extension, conservatory or garage or are requiring new roof coverings to the existing flat roofed areas of your property then you should be considering a Memtec Single Ply PVC membrane roofing or waterproofing system which will give you a modern, efficient and cost effective performance over many years. (Please note an experienced installer should always be employed). 1
3 Rochester Riverside Development Kent Three apartment blocks, bin and cycle store. 2500m 2 of Single Ply PVC membrane roof coverings, colour light grey. Photo courtesy of Denne. Memtec Single Ply PVC Roofing and Waterproofing Systems are suitable for all flat roof situations and can be either mechanically fixed, fully bonded or loose laid and ballasted. Typical specifications are: Warm roof, cold roof, roof terrace and green roof (i.e roof garden). Can be applied to most roof deck substrates such as timber, metal, concrete and roof screeds. Can be applied to gutter substrates such as metal, timber and concrete. Totally suitable for existing roof refurbishment projects whereby an insulated or non insulated overlay system/specification can be applied over the existing roof coverings (in most cases) without the need to strip them. Can be applied to bituminous felt, asphalt (with stone chippings removed) and mineral finish felt. Can replicate the appearance of Traditional Metal Roofing Systems such as Lead Roof Coverings by adding timber mop roll battens and Memtec cover flashings (i.e see page 3 of this brochure) and also Zinc Metal Standing Seam Roof Coverings by adding Memtec decarib PVC Profile type roof decoration. Memtec Products are not susceptible to theft as they have no re-sale value unlike the actual Lead and Metal Products which do have a re-sale value. Generally by employing the Memtec Product against the Traditonal Lead and Metal Products a cost saving of approximately fifty percent can be achieved. Can be applied to sloping mansard and dormer roof areas and if decorated, as above mentioned, will replicate metal standing seam or lead roll type roof coverings which could be of particular interest for church, religious, traditional and listed type buildings. Please carefully note building control regulations should always be consulted when considering an existing roof refurbishment project in regards to the requirement to install insulation to comply with current legal obligations. 2
4 General Applications Typical upstand flashing to kerb in foreground and parapets beyond A traditional lead roll covered roof is replicated by employing the Memtec Single Ply PVC Membrane and lead roll batten flashings in colour lead (dark) grey Showing upstand flashing Actual traditional lead covered roof on adjoining property. MEMTEC Modern efficient performance cost effective flat roofing systems 3 Memtec Single Ply PVC membrane roof with lead roll flashing roof decoration Please note the above photographs are for illustrative purposes only
5 Typical Specifications MECHANICAL FIXED SYSTEMS Mechanical fixed system cold roof specification Mechanical fixed system warm roof specification NB. Items 6 and 7 can be thermally broken, fastener type. 1. Roof deck substrate 4. Memtec Single Ply Membrane types MF or MF-FB 6. Plate washer and fastener ADHESIVE BONDED SYSTEMS Adhesive bonded adhered system cold roof specification 1. Roof deck substrate 8. Memcol adhesive 4. Memtec Single Ply Membrane types BM, BM-FB or MF-FB EXISTING ROOF REFURBISHMENT OVERLAY SYSTEMS Existing roof refurbishment non insulated adhesive bonded overlay system 1. Roof deck substrate 2. Vapour control layer 3. Insulation board 4. Memtec Single Ply Membrane types MF or MF-FB 6. Plate washer and fastener membrane fastening type 7. Plate washer and fastener insulation fastening type Adhesive bonded membrane warm roof specification 1. Roof deck substrate 2. Vapour control layer 3. Insulation board NB. Vapour control layer type bituminous felt and insulation board can be bonded with cold applied adhesive. or Vapour control layer type polyethylene can be loose laid and the insulation board mechanically fixed. 4. Memtec Single Ply Membrane types BM, BM-FB or MF-FB 8. Memcol adhesive Existing roof refurbishment insulated adhesive bonded overlay system NB. Item 4 can also be mechanically fixed as an option therefore item 8 can be omitted. NB. Items 3 and 4 can be mechanically fixed as an option therefore item 8 can be omitted. 1. Existing roof deck substrate 5. Existing roof covering s bituminous felt or asphalt with stone chippings removed 8. Memcol adhesive 4. Memtec Single Ply Membrane type BM-FB or MF-FB Please carefully note building control regulations should always be consulted when considering an existing roof refurbishment project in regards to the requirement to install insulation to comply with current legal obligations. 1. Existing roof deck substrate 5. Existing roof covering s bituminous felt or asphalt with stone chippings removed 8. Memcol adhesive 3. Insulation board 4. Memtec Single Ply Membrane types MF-FB, BM or BM-FB 4
6 Mechanically fixed system installation guide 1 Setting out of the pressure plate washers along the main field sheet edge and layout of the main field sheet overlap 2 Mechanical fixing of the membrane main field sheet 3 Hot air welding the overlap seam 4 Mechanical fixing of the drip edge trim MEMTEC Modern efficient performance cost effective flat roofing systems 5 Cover flashing main field sheet to drip edge trim 5
7 6 Cover flashing main field sheet to PVC faced drip edge trim 7 Hot air welding of the cover flashing 8 Adhesive application to upstand substrate 9 Adhesive application to upstand flashing 10 Hot air welding of the upstand flashing to the Memtec metal PVC faced 2.8 chase trim 11 Installed upstand detail with preformed corners All photos are for illustration purposes only and we reserve the right to amend and/or change details at any time without prior notice. 6
8 Adhesive bonded system installation guide 12 Adhesive application to deck substrate and membrane main field sheet 13 Membrane main field sheet bonded to deck substrate 14 Hot air welding of the overlap seam 15 Mechanical fixing of roof perimeter peel stop restraint bar 16 Adhesive application to upstand substrate and upstand flashing 17 Installing the membrane upstand flashing MEMTEC Modern efficient performance cost effective flat roofing systems 7 18 Hot air welding of the upstand flashing to the Memtec metal PVC faced 2.3 wall counter flashing trim 19 Hot air welding of the upstand flashing to the horizontal area main field sheet
9 20 Silicone sealant application to 2.3 wall counter flashing trim 21 Drip edge trim and membrane cover flashing 22 Hot air welding of roof decoration type decarib PVC profile (optional) 23 Installing a pipe flashing 24 Pipe flashing detail 25 Silicone sealant application to pipe flashing collar (note also requires a stainless steel jubilee clip or nylon cable tie) 26 Testing all hot air welded seams with a seam testing probe 27 General overview and appearance that can be achieved 8 All photos are for illustration purposes only and we reserve the right to amend and/or change details at any time without prior notice.
10 Products Memtec membrane type BM-FB and MF-FB fleece backed for mechanical fixed or bonded systems. Colours light or lead (dark) grey Memtec membrane types MF or BM non fleece backed for mechanical fixed or bonded systems. Colours light or lead (dark) grey Geotextile for isolation-separation to bituminous and polystyrene surfaces Memtec PVC decarib profile roof decoration to imitate a metal standing seam roof appearance. Colours light or lead (dark) grey Memtec metal PVC faced chase wall trim colours light or lead (dark) grey Memtec metal PVC faced drip edge trim colours light or lead (dark) grey. All size requirements catered for including bespoke sizes MEMTEC Modern efficient performance cost effective flat roofing systems 9 Memtec metal PVC faced 2.3 wall counter flashing trim colours light or lead (dark) grey Galvanised steel peel stop perimeter restraint bar for adhesive bonded systems
11 PVC internal corner colours light or lead (dark) grey PVC external corner colours light or lead (dark) grey Aluminium self adhesive tape. Application to insulation board joints with adhesive bonded systems Thermally broken washer and fixing for mechanically fixed membrane system to a warm roof specification i.e insulated Thermally broken washer and fixing for securing insulation board to roof deck. ie mechanical fixed method Pressure plate washer and fixing for lap fix mechanical fixed membrane system to a cold roof specification ie uninsulated Drive rivet fixings for Memtec metal trims to concrete or brickwork Vertical drain rainwater outlet, various diameters available Horizontal drain rainwater chute scupper Rainwater overflow PVC leafguard for vertical drain type rainwater outlets Memtec reserves the right to amend, change or substitute its products for equal similar approved products without prior notice. Memcol adhesive types CA and WB for bonded systems membrane types BM, BM-FB and MF-FB 10
12 Memtec Services Product Sales and Supplies including all accessories to complete and complement the system. Courier delivery service throughout the UK available (charges apply). Product Technical Advice and Support available. Product Installation Advice and Support available. Product Installation Guidance Classes available (charges apply). Product Literature and Samples available upon request. Our Senior Staff have over forty years experience of working within the main UK Single Ply PVC Membrane Roofing and Waterproofing Industry. We offer a Professional, Experienced and Friendly Service. For all further information contact Memtec Limited or visit our website. Memtec Limited Unit A, Brightside Westfield Sole Road Boxley Maidstone Kent ME14 3EH Tel: Fax: info@memtec.co.uk Website: MEMTEC Modern efficient performance cost effective flat roofing systems
System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY
CI/SfB Oct 12 (47) Ln Uniclass L524 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY Bailey Flame-free felt roofing Bailey
More informationEpdm Flat Roofing Systems
Epdm Flat Roofing Systems EDPM can be fully bonded, loose laid and ballasted or mechanically attached depending on the existing roof and its proposed usage. This applies to roofs to be refurbished and
More informationRoofing Systems. New Applications / Re-Roofing / Maintenance
Roofing Systems New Applications / Re-Roofing / Maintenance New Roof Installation In terms of the design and installation of an original roofing system (in conjunction with the construction of a new building),
More informationCONIROOF : Tailor-made Solutions for your Roof CONIROOF
CONIROOF : Tailor-made Solutions for your Roof CONIROOF Introducing the CONIROOF System BASF Construction Chemicals is one of the world s largest providers of construction products, systems and services
More informationRoofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.
Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
More informationSite Inspection Report
Site Inspection Report Project Title: 1 Canada Square Location: 1 Canada Square, Canary Wharf, London Date of Inspection: 16/05/12 System / Products: TBA (suggested flame free application) Attendees: G
More informationEXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES
Building and Construction Industry A joint industry initiative produced by BSA Supershow logo.indd 1 30/01/2008 9:43:29 AM EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES FAILING WATERPROOFING
More informationThe formation of roof waterproofing details calls for
3.5 BUILT-UP ROOFING DETAIL DESIGN INTRODUCTION The formation of roof details calls for a combination of the skills of the designer and the roofer. There are many different approaches to detail design
More information1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.
SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance
More information!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
More informationWATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
More informationLow Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Eighth Issue March 2011 TR27 LPC/FM INSULATION FOR FLAT ROOFS WATERPROOFED WITH FULLY ADHERED SINGLE PLY, PARTIALLY BONDED BUILT UP FELT, MASTIC ASPHALT AND COLD
More informationTITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09
TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09 PMT GUIDE # 10 Book of Order Section G-10.0102o: "The session is responsible for the mission and government of the particular church. It
More informationFirestone RubberGard The EPDM reference
Firestone RubberGard The EPDM reference EPDM Roofing Systems 1.000.000.000 m 2 of proven performance The Firestone heritage of success and quality is extended to the construction industry through the Firestone
More informationBuilt-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5
Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,
More informationUbiflex. Non-lead flashing system
Ubiflex Non-lead flashing system Ubiflex non-lead flashing Ubiflex is a non-lead waterproof flashing material which can be used in most applications where lead is traditionally used to provide a weatherproof
More informationCHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
More informationNRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry
More informationThe existing roof angle change terminations and flashings when sound and intact can be reused.
January 2, 2015 Summary Specification Re-Skinning an Existing Roof Maintenance and Repair Warranty Upgrade for Up to 30 Years Re-Skinning Over an Existing Roof with a New C-EPDM Membrane Using The Existing
More informationHIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
More informationVM ZINC : standing seam Guidelines for specification and installation
VM ZINC : standing seam Guidelines for specification and installation Junglim Architecture - QUARTZ-ZINC Roofing and cladding system in VM ZINC Roofs from a 3 pitch and facades Freedom with shape and appearance
More informationTriflex system: Triflex ProDetail. Solution type: Roof detail and repair waterproofing. Application: Overlay of existing substrate
CAD details Triflex ProDetail Triflex system: Triflex ProDetail Solution type: Roof detail and repair waterproofing Application: Overlay of existing substrate CAD details CAD S: CAD details Triflex ProDetail
More informationCHESTERFLEX ROOF WATERPROOFING MEMBRANES
CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED
More informationCertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs
CertainTeed Self-Adhering Roof Systems for Low Slope Residential Roofs Goes down fast. Stays on strong. Flintlastic SA performs in all the right ways. What s more important to you? Speed of installation,
More informationSECTION 07530 SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.
SECTION 07530 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section includes the flowing: 1. Removal of existing roofing membrane. Existing bur roof has one overlay and penetration mastic is asbestos containing.
More informationRHEPANOL RHEPANOL FK ROOF COVERING SYSTEM
Flachdach Technologie GmbH & Co KG Eisenbahnstrasse 6 8 68199 Mannheim Germany Tel: 00 49 621 8504-372 Fax: 00 49 621 8504-378 e-mail: export@fdt.de website: www.fdt.de APPROVAL INSPECTION TESTING CERTIFICATION
More informationSection 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane
Section Flat Roofs Warm deck single ply membrane Product: Rocksilk Krimpact Flat Roof Slab Fl01 Warm deck single ply membrane Product: Polyfoam ECO Roofboard Fl02 Warm deck built-up felt/ mastic asphalt
More information0845 0098 980 www.nicholsonsts.com
0845 0098 980 www.nicholsonsts.com ROOFTRAK The IFP is revolutionising the way we fix things to roofs. Technical Director of a leading UK roofing system manufacturer The ROOFTRAK-IFP A revolutionary solution
More informationLow Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Seventh Issue March 2011 TR26 LPC/FM INSULATION FOR FLAT ROOFS WATERPROOFED WITH MECHANICALLY FIXED SINGLE PLY WATERPROOFING High performance rigid thermoset insulation
More informationRoofing. Sarnafil S 327-15EL. Polymeric membrane for roof waterproofing. Product Description
Roofing Product Data Sheet Edition 02.2015 Identification no: 02 09 01 01 201 0 150000 Version no. 04 Sarnafil S 327-15EL Polymeric membrane for roof waterproofing Product Description Sarnafil S 327-15EL
More informationBLACK JACK ALL WEATHER ROOF COATING
PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.
More informationYour guide to home maintenance. Flat Roofs
Your guide to home maintenance Flat Roofs Your guide to home maintenance is a series of information leaflets that gives you all the information you need to keep your home in tiptop condition. Flat Roofs
More informationTR21. I n s u l a t i o n. Low Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Fourth Issue March 2011 TR21 INSULATION FOR FLAT ROOFS WATERPROOFED WITH PARTIALLY BONDED BUILT UP FELT AND MASTIC ASPHALT High performance rigid thermoset insulation
More informationThe Harold J. Becker Company, Inc.
The Harold J. Becker Company, Inc. It is the mission of The Harold J. Becker Company, Inc. to deliver the absolute best possible quality product at the most efficient cost to our clients, while providing
More informationRooflight INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary
More informationMechanically Fastened
Mechanically Fastened System Document MECHANICALLY FASTENED SYSTEM Product Information AlkorPlan F 35170 Calendered unreinforced membrane of flexible PVC. Conforms to UEAtc guidelines. Application Used
More informationNEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
More informationPolymeric membrane for roof waterproofing
Product Data Sheet Edition 09.2008 Revision no: 0 Identification no: 01 09 01 02 200 0 120000 Sarnafil TS 77-12 Polymeric membrane for roof waterproofing Construction Product Description Uses Characteristics
More informationSTANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.
More informationGREEN ROOF SYSTEMS ADVANCED LIQUID ROOFING SYSTEMS GREEN ROOF INFORMATION AND DESIGN GUIDE GREEN ROOF SYSTEMS
Sfb () Ln 0/ ADVANCED LIQUID ROOFING SYSTEMS GREEN ROOF INFORMATION AND DESIGN GUIDE ADVANCED SEAMLESS ROOFING SYSTEMS CONTENTS INTRODUCTION TO GREEN ROOFS TYPES OF GREEN ROOF POLYROOF SYSTEMS & SERVICES
More informationFinal inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
More informationBuilding Regulations for the Conservation of Fuel and Power
Insulation CI/SfB Rn7 M2 First Issue April 2014 Building Regulations for the Conservation of Fuel and Power ENGLAND EXISTING DWELLINGS 2013 EDITION Low Energy Low Carbon Buildings Contents Page Introduction
More informationAsphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
More informationProteus Waterproofing roof systems are tested to the most rigorous international standards, ensuring they will easily deal with our climate.
INTRODUCTION Manufactured in the UK, the Proteus Waterproofing range of high performance roof & balcony systems has been engineered to meet the harshest of weather conditions and provide a lasting and
More informationSECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING
SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More information!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!
Table of Contents Section 1: Most Common Types of Flat Roofing Section 2: Better Understand Your Flat Roof Section 3: Flat Roofing Cost in 2015: Four Factors that Dictate Section 4: Planning A Flat Roofing
More informationInterior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM
P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer
More informationSEAMS SEAMING USING SEAM TAPE
SEAMING USING SEAM TAPE SEAMS The membrane should be positioned so that the width of the seam is 3. Remove excess chalk from a chalk line by snapping the line into the air and then chalk a line one-quarter
More informationDocument type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5. 1. Purpose
Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5 1. Purpose The purpose of this practice note is to address the incidence of deck and roof membrane
More informationAlthough we do a fair amount of residential roofing, my family s breadand-butter. Installing a. Sealants aren t universal
Installing a Low-Slope Exposed EPDM for roof transition Exposed EPDM for resistance to ice damming Sidewall flashing Done with care, a flat roof can provide 0 years or more of leak-free service Gravel
More informationFATRA ROOF COVERING SYSTEMS FATRAFOL FF807 AND FATRAFOL FF807/V ROOF COVERING SYSTEMS
Fatra UK Ltd Unit 12 The Timber Yard East Moors Road Ocean Park Cardiff CF24 5EE Tel: 029 2048 7954 Fax: 029 2048 9226 e-mail: sales@fatra.co.uk website: www.fatra.co.uk FATRA ROOF COVERING SYSTEMS APPROVAL
More informationRecord of Work Experiences Trade Qualifier or Pre-Apprenticeship Credits ROOFER
Department of Advanced Education and Skills Apprenticeship and Trades Certification Division Record of Work Experiences Trade Qualifier or Pre-Apprenticeship Credits ROOFER Note to Apprenticeship Applicants
More informationResidential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
More informationITEM 599.06060008 THERMOPLASTIC MEMBRANE ROOFING
DESCRIPTION Construct adhered membrane roofing system, roof insulation, and vapor retarder in accordance with these specifications. MATERIALS: General: Provide installed roofing membrane and base flashings
More informationCITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
More informationSECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
More informationConstruction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description
Product Data Sheet Edition 15/10/2014 Identification no: 02 07 04 10 300 0 000002 SikaProof A Edge SikaProof A-08 Edge, A-12 Edge Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing
More informationWATERPROOFING FOR CONCRETE STRUCTURES
MANUAL OF CONTRACT DOCUMENTS FOR ROAD WORKS VOLUME 1 SPECIFICATION FOR ROAD WORKS SERIES 2000 WATERPROOFING FOR CONCRETE STRUCTURES Contents Clause Title Page 2001 General 2 2002 Protection of Bridge Deck
More informationDENSO WATERPROOFING SYSTEMS
DENSO WATERPROOFING SYSTEMS Approved Quality Management System AS/NZS ISO 9001:2008 Lloyds Register Certificate N o Mel 0927759 Denso (Australia) Pty Ltd A MEMBER OF WINN & COALES INTERNATIONAL 411 413
More informationBituminous Sheet Flat Roofs: Their repair and maintenance
Bituminous Sheet Flat Roofs: Their repair and maintenance Flat roof covered in sheets of bituminous felt Introduction Whilst flat roofs are often regarded as inferior to their pitched counterparts and
More informationDELTA Premium Moisture Management Systems for Foundations.
DELTA protects property. Saves energy. Creates comfort. DELTA Premium Moisture Management Systems for Foundations. DELTA Premium Moisture Management Systems provide the best protection for foundations.
More informationIncluding. Rubershield-Pro. Breather Membrane
Including RubershieldPro Breather Membrane 2 Ruberoid produces a wide range of underslating membranes, primarily to be installed below tiles, slates or metal roofing providing a secondary barrier against
More informationBITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC.
93-106 Revised March 2007 BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC. BITEC APM-4.5T is a torch applied, mineral surfaced,
More informationRe-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY
Insulation for Above the Deck WALL SPECIALTY PRODUCT DESCRIPTION Rmax Re-Cover Board-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded
More information3 Installation. 9 Roof Edges... p. 3. 19 10 Wall Terminations... p. 3. 20 11 Membrane Repair... p. 3. 21 12 Miscellaneous... p. 3. 22. 3.
3 Installation The information provided within this chapter may assist the contractor to install the Firestone UltraPly TPO Systems in accordance with Firestone s requirements. It may also help him and
More informationSchluter -KERDI-BOARD Substrate, building panel, bonded waterproofing
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of
More informationFLAT ROOF INSULATION INSULATION ROOFING FLAT. Quick Guide. Quick Guide. Insulation. EcoTherm Insulation UK Sales Team. Insulation
Insulation Insulation Scotland & North England 07824 412579 North West & North Wales 07931 342948 South Wales & West Midlands 07940 546247 Yorkshire & East Midlands 07825 570100 FLAT ROOF INSULATION EcoTherm
More information12.1 Schlüter -KERDI-BOARD
I n n o v a t i v e p r o f i l e s 12.1 Schlüter -KERDI-BOARD S u b s t r a t e U N I V E R S A L S T R U C T U R A L P A N E L, B O N D E D W A T E R P R O O F I N G Application and Function Schlüter
More informationSECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. This section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,
More informationAPPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET
Environmental Protection and Growth Management Department PERMITTING, LICENSING AND CONSUMER PROTECTION DIVISION 1 N. University Drive, Box #302 Plantation, Florida 33324 954-765-4400 www.broward.org/permittingandlicensing
More informationA. This Section includes rubberized asphalt sheet membrane waterproofing systems.
SECTION 07110 SHEET MEMBRANE WATERPROOFING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationSikaProof A Technology
SikaProof A Technology The fully bonded waterproofing system Keep your basements durably and securely watertight What is SikaProof A? How does it work? Where can it be used? What are the advantages of
More informationLinea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1
Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.
More informationINTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
More information3 BUILT-UP ROOFING THE RUBEROID BLUE BOOK
3 BUILT-UP ROOFING 3.1 MATERIALS 3.2 APPLICATION TECHNIQUES 3.3 SURFACE PROTECTION 3.4 TYPICAL SPECIFICATIONS 3.5 BUILT-UP ROOFING DETAIL DESIGN 3.6 TYPICAL DETAILS 3.1 MATERIALS INTRODUCTION Bituminous
More informationSmooth cap sheet - 0-10 SQ $ 139.00. Smooth cap sheet - 11-50 SQ $ 63.00. Smooth cap sheet - 51-100 SQ $ 36.00 Smooth cap sheet - 101-200 SQ $ 36.
Demolition/Removal of Work 4-ply built up roofing to the insulation (smooth cap sheet) Smooth cap sheet - 0-10 SQ $ 63.00 Smooth cap sheet - 11-50 SQ $ 63.00 Smooth cap sheet - 51-100 SQ $ 35.00 Smooth
More information3 Installation. 3. Installation. EPDM Installation
3 Installation The information provided within this chapter may assist the contractor to install the Firestone EPDM Systems in accordance with Firestone s requirements. It may also help him and the designer
More informationUNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design
Basis of Design This section applies to roofing membranes, flashing and accessories. Design Criteria Adhere to the standards and details of the latest editions of the National Contractors Association (NRCA)
More informationSyphonic Roof Drainage
Page 1 T E C H N O L O G Y 2:39 pm Syphonic Roof Drainage P L U M B I N G 23/5/03 A D V A N C E D Prod & Price Gd.for PDF Product Guide SYPHONICS Advanced Roof Drainage Technology Geberit Syphonics Geberit
More informationProduct Catalogue. Roofing and Waterproofing Membranes
Product Catalogue Roofing and Waterproofing Membranes Table of Contents Welcome to Protan 3 Function of Protan Roofs 5 Environment and Quality 6 Protan Polyester Reinforced Range 7 Protan Glass Fibre Reinforced
More informationSINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION
SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION As of October 1, 2007, this mitigation form must be submitted as part of the roofing permit application package. Secondary water barrier (if applicable)
More informationSchlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
More informationConsultants Handbook
Consultants Handbook CONSULTANTS HANDBOOK Welcome to our Wallis Designers Lightning Protection Handbook. This handbook offers a guide for any designers of the structural Lightning protection system to
More informationSection 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
More informationINDIAN HEAD ELEMENTARY SCHOOL
ROOF ASSESSMENT REPORT INDIAN HEAD ELEMENTARY SCHOOL NOVEMBER 08, 2010 PREPARED FOR: FACILITIES DEPARTMENT WHITMAN HANSON REGIONAL SCHOOL DISTRICT 1. Purpose This Roofing Assessment Report provides a summary
More informationINSTALLATION GUIDE. americanwick.com 800.242.WICK (9425)
INSTALLATION GUIDE americanwick.com 800.242.WICK (9425) American Wick Drain SITEDRAIN prefabricated drainage products may be installed in a variety of civil construction applications including: retaining
More informationMonarflex Vapour Control Layers
Monarflex Vapour ontrol Layers I/Sf 27.2 May 2008 N6 The simple and cost effective way to reduce air leakage, maximise thermal performance and prevent harmful condensation. High performance VL s designed
More informationMedicam house, Saint Germain Lambron - Architect: Trinh et Laudat - Contractor: Entreprise Duche. Roofing with VMZINC
Medicam house, Saint Germain Lambron - Architect: Trinh et Laudat - Contractor: Entreprise Duche Roofing with VMZINC ROOFING Cold roofs with ventilated substructures Chosen in the past for its unrivalled
More informationPlease read the entire document before purchasing and installing any of these products
Please read the entire document before purchasing and installing any of these products USA SBS UNDERLAYMENT ROOFING UNDERLAYMENT SBS Mineral Surfaced MINERAL SURFACE CAP SHEET Ice and Water Protection
More informationSECTION 07720 PREFORMED METAL STANDING SEAM ROOFING
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationMulti-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof
More informationTunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM
P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 5 Tunnels & Arches V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V Create dry usable space with the original X pattern
More informationSTANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS
ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the
More informationTechnology at its best. Benefits
Protecting what s under your roof from the elements is simplicity itself with Ruberoid Roofing Shingles. Roofing Shingles make ideal roofing; they are attractive, easy to install and are perfect for use
More informationFLAGON PVC SINGLE-PLY ROOF WATERPROOFING SYSTEMS FLAGON SFc, SFb AND SV ROOF WATERPROOFING SYSTEMS
Flag-Soprema UK Ltd Unit 640, Avenue West Skyline 120 Great Notley Essex CM77 7AA Tel: 0845 194 8727 Fax: 0845 194 8728 e-mail: enquiries@flag-soprema.co.uk website: www.flag-soprema.co.uk APPROVAL INSPECTION
More informationRoof Repair Project Report. Fairbank Complex 40 Fairbank Road Sudbury, Massachusetts. February 14, 2014. RBA Project No. 2014007.00.
Report Fairbank Complex 40 Fairbank Road RBA Project No. 2014007.00 Prepared by: 33 Center Street, 2 nd Floor Burlington, MA Tel: 781-273-1537 Fax: 781-273-1695 TABLE OF CONTENTS Roof Repair Project Report...
More informationSheet A-1 KEY SHEET A-1. Football Roof Plan SHEET A-2 SHEET A-3 SHEET A-4. LaCross Roof Plan. Soccor 2 Roof Plan 88' 45' 87' 46' 45' 45' 10' 3' 25'
Sheet A-1 SHEET A-1 Football Roof Plan 5 LaCross Roof Plan 5 88' 87' SHEET A- 1 DRIP EDGE WITH STANDING SEAM PANEL 2 RAKEWALL SHEET A- RIDGE HIP HEAD WALL 11700 Pierson Rd. Wellington, FL. 1 Soccor 2 Roof
More information