1 INSTALLATION GUIDE FOR RESISTO ROOFING PRODUCTS 3 EAVES PROTECTION Time-tested premium quality products Whether you re building or renovating, RESISTO products offer effective solutions for preventing and eliminating water leaks. Manufactured by SOPREMA, RESISTO products are the benchmark for residential waterproofing EAVES AND CONSTRUCTION DETAIL WATERPROOFING LOW SLOPE ROOFS Single-ply and two-ply systems RESTORATION AND REPAIR OF METAL ROOFS OTHER ROOFING PRODUCTS L LS CHOICE PROFESSIONAL S PROFESSIONAL CHOICE THE Warranty RESISTO products are guaranteed against manufacturing defects and are suitable for the uses for which they are designed. SOPREMA S responsibility under this warranty is limited to the replacement of defective RESISTO products. AR-157 PRINTED IN CANADA CUSTOMER SERVICE
2 2 ROOFS ROOFS 3 EAVES PROTECTION (under shingles) The RESISTO LASTOBOND Sanded Finish Eaves Protection Membrane is the ideal solution for effective eaves protection. LASTOBOND EAVES PROTECTION SHEET SANDED FINISH SELF-ADHESIVE ELASTOMERIC REQUIRED TOOLS L LS CHOICE PROFESSIONAL S PROFESSIONAL CHOICE THE REQUIRED PRODUCTS OR Primer is not required if the covering material is installed the same day. RECOMMENDED USES Eaves protection membranes can be used on roof edges, ridges, valleys, and around any other element crossing the roof. These areas are especially exposed to water leaks due to ice accumulation or strong winds. This membrane is not recommended for metal roofs. APPLICATION TEMPERATURE Minimum application temperature 40 F (5 C) LASTOBOND SANDED FINISH EAVES PROTECTION is a 63-mil-thick (1.6 mm) self-adhesive membrane composed of glass mat-reinforced elastomeric bitumen. The top surface is lightly sanded for safety and the self-adhesive bottom surface is covered with an easy-toremove, silicone-treated, split-back, release sheet. LASTOBOND withstands temperature variations ranging from -40 F to 200 F (-40 C to 93 C). LASTOBOND is used as an eaves protection membrane under asphalt shingles. Provides additional protection Effective and hard-wearing Provides superior protection against bad weather and temperature fluctuations Adheres to wood Quick, easy, mess-free installation Requires no special tools Requires no primer if the covering material is installed the same day
3 4 ROOFS ROOFS 5 EAVES PROTECTION (under shingles) APPLICATION CONDITIONS The minimum application temperature of the RESISTO LASTOBOND SANDED FINISH EAVES PROTECTION membrane is 40 F (5 C). It is important that products be brought to ambient temperature before use. SUBSTRATE* Plywood OSB panels (Aspenite) Asphaltic panels (RESISTOBOARD) * Tongue and groove boards must be covered with one of the three materials listed above. On new tongue and groove boards, cover only with plywood or OSB panels. Peel back the remaining release sheet. Fig. ➍ Press down on the membrane with a small rubber roller to increase adhesion. Fig. ➎ ➊ INSTALLING THE RESISTO LASTOBOND SANDED FINISH EAVES PROTECTION Install on a clean, dry surface. RESISTO PRIMER can increase adhesion to certain substrates. Note: H2O PRIMER is not compatible with the RESISTOBOARD asphaltic panels. Position the membrane parallel to the edge of the roof. Fig. ➊ Pell back the release sheet 4 in (10 cm). Fig. ➋ Apply the membrane as positioned. Continue peeling back the release sheet. Press down on the membrane with a small rubber roller to increase adhesion. Fig. ➌ ➋ ➌ ➍ If you have to apply the membrane to a surface of more than one meter in width or overlap two pieces of membrane, the overlap should be 3 in (8 cm) wide. ➎
4 6 ROOFS ROOFS 7 EAVES AND CONSTRUCTION DETAIL WATERPROOFING RESISTO LASTOBOND PRO HT-N or HT-S Eaves protection membrane is the ideal solution for high performance eaves and construction detail waterproofing protection. REQUIRED TOOLS LASTOBOND PRO HT-N/HT-S EAVES PROTECTION SHEET HIGH PERFORMANCE SELF-ADHESIVE ELASTOMERIC L LS CHOICE PROFESSIONAL S PROFESSIONAL CHOICE THE REQUIRED PRODUCTS OR Primer is not required if the covering material is installed the same day. Primer is always required for vertical details. RECOMMENDED USES Roof underlayment for roof edges and construction details - Dormers - Valleys - Ridges - Vents - Skylights - etc. Irregular and regular medium and steep slope roofs. Low slope roofs perimeter (SINGLE-PLY SYSTEM) APPLICATION TEMPERATURE Minimum installation temperature HT-N : 40 F (5 C) HT-S : 50 F (10 C) HIGH PERFORMANCE LASTOBOND PRO HT-N and HT-S EAVES PROTECTION are 40-mil-thick (1.0 mm) self-adhesive, waterproofing membranes composed of elastomeric bitumen and trilaminate woven polyethylene. They withstand temperature variations of: HT-N -40 F to 200 F (-40 C to 93 C) HT-S -40 F to 250 F (-40 C to 121 C) The top surface is non-slip and the self-adhesive bottom surface is covered with an easy-to-remove silicone-treated, split-back, release sheet. LASTOBOND PRO HT-N and HT-S membranes are high performance roof underlayment membranes for use with any type of roof covering. Non-slip surface Self-sealing Easy, mess-free installation UV resistant (90-day exposure) Heavy duty surface film Effective and hard-wearing No special tools required
5 8 ROOFS ROOFS EAVES AND CONSTRUCTION DETAIL WATERPROOFING APPLICATION CONDITIONS The minimum application temperature of these RESISTO LASTOBOND PRO HIGH PERFORMANCE EAVES PROTECTION is 40 F (5 C) for the HT-N and 50 F (10 C) for the HT-S. It is important that products be brought to ambient temperature before use. SUBSTRATE* Plywood OSB panels (rough side up) Asphaltic panels (RESISTOBOARD) * Tongue and groove boards must be covered with one of the three materials listed above. On new tongue and groove boards, cover only with plywood or OSB panels. INSTALLING THE LASTOBOND PRO HT-N or HT-S LASTOBOND PRO membranes are used to reinforce roof edges and areas at risk of water leakage such as ridges, valleys, parapets, and upstands. Position the membrane parallel to the edge of the roof, leaving a 3 in (8 cm) overhang on the edge where the gutter will be installed. Fig. C Please refer to the RESISTO LASTOBOND SANDED FINISH EAVES PROTECTION section (pages 4 and 5) for installation instructions. If you have to apply the membrane to a surface of more that one meter in width or overlap two pieces of membrane, the overlap should be 3 in (8 cm) wide. ➊ 9 ➌ ➐ ➍ ➑ ➎ ➒ ➏ ➓ EDGE FLASHING Once the metal edge flashing has been installed, overlap the flashing and the membrane installed along the edge of the wood with a 4 in (10 cm) strip of RED ZONE or LASTOBOND PRO membrane. Fig. ➊ ➋ PREPARING CONSTRUCTION DETAILS RESISTO PRIMER or ELASTOMERIC SEALER, depending on the porosity of the substrate, is required for this step. Upstands (walls, chimneys) Install a gusset (a small piece of membrane). Fig. ➌ ➐ Cut a strip of membrane 8 in (20 cm) wide. Apply the membrane to the roof and vertical surface, overlapping each by 4 in (10 cm). Always begin at the bottom of the detail to be protected (Fig. ➍ ➑) and end at the highest point. Fig. ➏ ➓ Round protrusions Attach the cap flashing and metal base to the surface of the roof. Cut a circular opening in a piece of LASTOBOND PRO membrane that is 2 in (5 cm) larger than the diameter of the protrusion. The membrane should exceed the metal base by 4 in (10 cm). Fig. A If it is impossible to install the membrane this way, use two pieced, overlapping them by 3 in (8 cm) Fig. B LASTOBOND PRO membrane exceeding a metal base by 4 in (10 cm) A Metal base B ➋ C
6 10 ROOFS ROOFS 11 LOW SLOPE ROOFS SINGLE-PLY SYSTEM RESISTO offers a much more resistant and durable alternative than shingles or other conventional roofing materials for low-slope roofs. An HR CAP SHEET is used in a single-ply system* (with a LASTOBOND PRO reinforcement membrane on the edges of the roof and construction details) provides reliable, long-lasting waterproofing protection. The RESISTO HR CAP SHEET is a premium quality roof covering that will withstand the extreme conditions low slope roofs typically endure. * Slopes >1:12 or 8% ** Slopes >_ 1/8:12 or 1% TWO-PLY SYSTEM RESISTO BASIC WATERPROOFING (1 st ply) and HR CAP SHEET (2 nd ply) are the ideal waterproofing solution for low slope roofs. They are especially effective on very low slope roofs** where shingles and other conventional coverings are much less long-lasting and not very attractive, such as on house additions, cottages, garages, annexes, carports, sheds, workshops, and other buildings. REQUIRED TOOLS REQUIRED PRODUCTS OR OPTIONAL PRODUCTS HR CAP SHEET HIGH RESISTANCE SELF-ADHESIVE ELASTOMERIC L LS CHOICE PROFESSIONAL S PROFESSIONAL CHOICE THE The HR CAP SHEET is a 150-mil-thick (3.8 mm) self-adhesive membrane composed of elastomeric bitumen reinforced with a high resistance (HR) composite. The exposed top surface of the membrane is protected by coloured granules (grey, black, brown or green). The self-adhesive bottom surface is covered with an easy-to-remove, silicone-treated, release sheet (split-back). The HR CAP SHEET is used in single-ply and two-ply waterproofing systems on low slope roofs. Easy, quick, and no-mess installation Remains flexible at low temperatures Resists UV radiation Effective and hard-wearing Reinforced with high resistance composite Requires no special tools RECOMMENDED USES Low slope roofs (single-ply and two-ply systems) Semi-flat roofs (two-ply system) NOTE : For installation on a flat roof (roof that drains towards an interior drain), please contact RESISTO for more information on the CONTRACTOR Program. APPLICATION TEMPERATURE Minimum application temperature 50 F (10 C) See pages for information on these products.
7 12 ROOFS ROOFS 13 (LOW SLOPE ROOFS) SINGLE-PLY SYSTEM APPLICATION CONDITIONS The minimum application temperature of the membranes is 50 F (10 C). They must be installed on a clean, dry surface. It is important that products be brought to ambient temperature before use. SUBSTRATE* The substrate must be sound and in good condition. Make sure that there are no protruding nails or screws. Plywood OSB panels (rough side up) Asphaltic panels (RESISTOBOARD) * Tongue and groove boards must be covered with one of the three materials listed above. On new tongue and groove boards, cover only with plywood or OSB panels. The slope of the roof must be at least 1:12 or 8%. The maximum slope for nail-free installation is 4:12 or 30%. IMPORTANT : For slopes over 4:12 (30%), the top edge of the membrane must be mechanically fastened using 1 in (2.5 cm) steel-washered roofing nails every 12 in (30 cm) c/c. APPLYING RESISTO PRIMER Mix the primer thoroughly before applying. Use a brush or roller to apply a coat of RESISTO PRIMER to a clean, dry surface. NOTE: H 2 O PRIMER is not compatible with RESISTOBOARD asphaltic panels. Drying time ½ hour to 3 hours, depending on application conditions. The drying time can vary depending on the ambient temperature and the thickness applied, as well as the type of substrate. Coverage EXTERIOR PRIMER: 1 L covers 32 to 55 ft 2 (3 to 5 m 2 ) H 2 O PRIMER : 1 L covers 32 to 96 ft 2 (3 to 9 m 2 ) Coverage may vary depending on the permeability of the substrate. The primer is dry when sticky but not messy when touched. NOTE: Primed surfaces may be slippery until the primer dries. Be careful when walking on the roof. INSTALLING THE LASTOBOND PRO HT- N or HT-S PERIMETER The LASTOBOND PRO membrane must be installed as a reinforcement at the perimeter of the roof and other areas at risk of water leakage such as ridges, valleys, parapets, and upstands of the roof before the HR CAP SHEET is installed. Position the membrane parallel to the edge of the roof, leaving a 3 in (8 cm) overhang on the edge where the gutter will be installed. Fig. ➐ If the gutter is already installed, apply the membrane beginning at the edge of the roof. Install the membrane two rolls wide at the bottom of the slope (near the gutter) and one roll wide around the remaining roof edge and the construction details. Fig. ➐ Unroll and position the membrane. Peel back the release sheet on the bottom surface by 12 to 16 in (30 to 40 cm) and fold back to one side. Adhere the uncovered part to the substrate. Fig. ➊ Holding the other end of the membrane, gradually peel back the release sheet and, using a push broom (or other accessory); press the membrane onto the substrate while continuing to slowly peel back the release sheet. Adhere the membrane in the centre first, and then press outward to the edges. Fig. ➋ Apply pressure on the membrane using a metal or hard rubber roller to ensure it adheres completely to the base, taking care to avoid the formation of blisters, wrinkles, and fishmouths. Overlap the sides by 3 in (8 cm). Overlap the ends by 6 in (15 cm). ➌ ➍ ➎ ➏ SEALER ADHERED part ➊ Silicone-treated release sheet EDGE FLASHING Once the membrane is installed, attach the metal edge flashing. Overlap the flashing and the membrane installed along the edge of the roof with a 4 in (10 cm) strip of RED ZONE or LASTOBOND PRO membrane. PROTECTING CONSTRUCTION DETAILS Use LASTOBOND PRO HT-N and/or RED ZONE membrane. See the illustrations on page 9 of this guide. INSTALLING THE HR CAP SHEET The HR CAP SHEET should be installed horizontally, beginning at the bottom of the slope. Install the membrane directly on the surface to be covered, beginning at the lower edge of the roof. Unroll and position the membrane. Fig. ➌ Fold the membrane back on itself over half its width, i.e., 20 in (50 cm), along the entire length of the pre-positioned membrane. Fig. ➍ Kneel on the unfolded section to make sure it does not shift during this operation. Peel back the release sheet from the folded section, letting the membrane fall back on the substrate. The self-adhesive surface will come into contact with the substrate. Fig. ➍ Then, fold back the other half of the HR CAP SHEET and repeat the preceding steps. Immediately press down on the membrane with a metal or hard rubber roller. Fig. ➎ Make sure the membrane adheres completely to the substrate to avoid the formation of blisters, wrinkles, and fishmouths. For steep slope roofs, the HR CAP SHEET should preferably be installed vertically, by positioning the first strip along one vertical edge of the roof. Unroll and position the membrane vertically, parallel to the slope of the roof. The RESISTO single-ply roofing system is guaranteed for 15 years against any manufacturing defects that could cause leaks. This warranty applies to all low slope residential roofs that drain to the outside edge and that do not have roof drains. The slope of the roof must be at least 1:12 or 8%. For details on warranty terms and conditions, consult the warranty form available at home renovation centres. ➋ STRETCHING Silicone-treated release sheet STRETCHING NOTE Use the selvage (approx. 4 in (10 cm)) to ensure a good overlap of the membrane strips. The overlap must be at the top of the slope. Overlap the ends of two strips of HR CAP SHEET by 6 in (15 cm). First apply enough RESISTO ELASTOMERIC SEALER to cover the granules of the membrane to be overlapped. Fig. ➏ ➐ PREPARING ROOF CONSTRUC- TION DETAILS FOR THE HR CAP SHEET See the illustrations on page 17 of this guide. RESISTOFLASH is also an excellent solution for preparing roof construction details. See page 27 of this guide for application instructions. SINGLE-PLY SYSTEM
8 14 ROOFS ROOFS 15 APPLICATION CONDITIONS The minimum application temperature of the membranes is 50 F (10 C). The membranes should be installed on clean, dry surfaces. It is important that products be brought to ambient temperature before use. SUBSTRATE The substrate must be sound and in good condition. Make sure that there are no protruding nails or screws. Plywood OSB panels (rough side up) Asphaltic panels (RESISTOBOARD) * Tongue and groove boards must be covered with on of the three materials listed above. On new tongue and groove boards, cover only with plywood or OSB panels. The slope of the roof must be at least 1/ 8:12 or 1%. The maximum slope for nail-free installation is 4:12 or 30%. IMPORTANT : For slopes greater than 4:12 (30 %), the top edge of the membrane must be mechanically fastened using 1 in (2.5 cm) steel-washered roofing nails every 12 in (30 cm) c/c. The RESISTO two-ply roofing system is guaranteed for 20 years against all manufacturing defects. This warranty applies to low slope or virtually flat residential roofs with slopes up to 1/8:12 or 1% that drain to the outside edge and that do not have roof drains. For more details about the terms and conditions of the warranty, consult the warranty form available at home renovation centres. APPLYING RESISTO PRIMER Mix the primer thoroughly before applying. Use a brush or roller to apply a coat of RESISTO PRIMER to a clean, dry surface. Note: H 2 O PRIMER is not compatible with RESISTOBOARD asphaltic panels. Drying time ½ hour to 3 hours, depending on application conditions. The drying time can vary depending on the ambient temperature and the thickness applied, as well as the type of substrate. TWO-PLY SYSTEM Coverage EXTERIOR PRIMER: 1 L covers 32 to 55 ft 2 (3 to 5 m 2 ). H 2 O PRIMER : 1 L covers 32 to 96 ft 2 (3 to 9 m 2 ). Coverage may vary depending on the permeability of the substrate. The primer is dry when sticky but not messy when touched. NOTE: Primed surfaces may be slippery until the primer dries. Be careful when walking on the roof. ➊ (FINISHING LOW SLOPE ROOFS) TWO-PLY SYSTEM INSTALLING THE RESISTO BASIC WATERPROOFING (1 st WATERPROOFING LAYER) NOTE The BASIC WATERPROOFING must be installed as the first waterproofing layer before the HR CAP SHEET. The first strip of membrane must be 20 in (50 cm) wide so the HR CAP SHEET, which will be installed later, overlaps the joint of the first layer. Fig. ➊ Position the membrane parallel to the edge of the roof, leaving a 3 in (8 cm) overhang on the edge where the gutter will be installed. If the gutter is already installed, apply the membrane beginning at the edge of the roof. Fig. ➊ Unroll and position the membrane. Peel back the release sheet on the bottom surface by 12 to 16 in (30 to 40 cm) and fold back to one side. Adhere the uncovered part to the substrate. Fig. ➋ Holding the other end of the membrane, gradually peel back the release sheet and, using a push broom (or other accessory); press the membrane onto the substrate while continuing to slowly peel back the release sheet. Adhere the membrane in the centre first, and then press outward to the edges. Fig. ➌ Apply pressure on the membrane using a metal or hard rubber roller to ensure it adheres completely to the base, taking care to avoid the formation of blisters, wrinkles, and fishmouths. Overlap the sides by 4 in (10 cm). Overlap the ends by 6 in (15 cm). Silicone release sheet EDGE FLASHING Once the membrane is installed, attach the metal edge flashing (Fig. ➍) Overlap the flashing and the membrane installed along the edge of the roof with a 4 in (10 cm) strip of BASIC WATERPROOFING or RED ZONE membrane. Fig. ➎ ➍ ➎ PREPARING ROOF CONSTRUCTION DETAILS (1 st waterproofing layer) Use BASIC WATERPROOFING or RED ZONE membrane. See the illustrations on page 16 of this guide. INSTALLATION METHOD CONTINUED ON THE FOLLOWING PAGE. ➋ STRETCHING ADHERED part ➌ Silicone release sheet STRETCHING
9 16 ROOFS ROOFS 17 (FINISHING LOW SLOPE ROOFS) TWO-PLY SYSTEM For low slope roofs, the HR CAP SHEET should preferably be installed horizontally beginning at the bottom of the slope. Install the membrane directly on the surface to be covered, beginning at the lower edge of the roof. Unroll and position the membrane. Fold the membrane back on itself over half its width, i.e., 20 in (50 cm), along the entire length of the pre-positioned membrane. Kneel on the unfolded section to make sure it does not shift during this operation. Fig. ➏ Peel back the release sheet from the folded section, letting the membrane fall back on the substrate. The self-adhesive surface will come into contact with the substrate. Then, fold back the other half of the HR CAP SHEET ( and repeat the DE two FINITION preceding HR steps. Immediately SEULEMENT) press down on the membrane with a metal or hard rubber roller. Fig. ➐ Make sure the membrane adheres completely to the substrate to avoid the formation of blisters, wrinkles, and fishmouths. For steep slope roofs, the HR CAP SHEET should preferably be installed vertically by positioning the first strip along one vertical edge of the roof. Unroll the membrane vertically, parallel to the slope of the roof. NOTE Use the selvage (approx. 4 in (10 cm)) to ensure a good overlap of the membrane strips. The overlap must be at the top of the slope. Overlap the ends of two strips of HR CAP SHEET by 6 in (15 cm). First apply enough RESISTO ELASTOMERIC SEALER to cover the granules of the membrane to be overlapped. Fig. ➑ The overlaps of the ends of the membrane must be staggered by 18 in (46 cm). Fig. ➓ ASSEMBLY WHERE THREE S OVERLAP When three membranes overlap, cut the centre membrane at a angle over a distance of 4 in (10 cm). Fig. ➑ ➒ SEALER ➑ ➏ ➐ FINISHING CONSTRUCTION DETAILS 1. RESISTOFLASH is an excellent solution for preparing roof construction details. (See page 27 of this guide for application instructions). 2. RESISTO HIGH RESISTANCE HR CAP SHEET (See details below when using a hot air gun). FRONT ➒ 4" (10 cm) 4" (10 cm) MIN. 18" (46 cm) ➓ SEALER FRONT SEALER RESISTO ELASTOMERIC SEALER RESISTO PRIMER METAL FLASHING HR CAP SHEET BASIC WATER- PROOFING TWO-PLY SYSTEM ALU ELASTOMERIC SEALER BACK 6 OVERLAP
10 18 ROOFS ROOFS RESTORATION AND REPAIR OF METAL ROOFS The MULTIPURPOSE ALUMINUM WATERPROOFING is the ideal solution for waterproofing metal siding and roofs. REQUIRED TOOLS ALUMINUM WATERPROOFING MULTIPURPOSE SELF-ADHESIVE ELASTOMERIC PROFESSIONAL S PROFESSIONALS CHOICE THE REQUIRED PRODUCTS RECOMMENDED USES The ALUMINUM WATERPROOFING eliminated air infiltrations and water leaks. It is easy to apply on wood, shingle, concrete, zinc, aluminum, and metal surfaces. It is used to seal the following: Roof details: ventilation equipment, vents, valleys, and flashing Solariums, dormers and skylights Chimney bases Gutters, ducts, and pipes Mobile homes, campers, motorized vehicles, and trailers OR The MULTIPURPOSE ALUMINUM WATERPROOFING is a 40-mil-think (1.0 mm) self-adhesive membrane composed of elastomeric bitumen. The top exposed surface of the membrane is covered with a high resistance aluminum sheet. The self-adhesive bottom surface is covered with an easy-to-remove silicone-treated release sheet. The MULTIPURPOSE ALUMINUM WATERPROOFING is designed to waterproof small maintenance and repair jobs. Provides effective protection for up to 10 years Is simple to install and required no primer Is highly resistant to poor weather, temperature fluctuations, and UV radiation Does not require a finishing material Lowers roof surface temperature Can be applied without special tools Other applications: Consult the RESISTO products «VARIOUS WATERPROOFING» guide. RESISTO PRIMER can increase adhesion to certain surfaces. APPLICATION TEMPERATURE The minimum application temperature for the ALUMINUM WATER- PROOFING is 50 F (10 C). It is important that products be brought to ambient temperature before use. SURFACE PREPARATION Inspect your roof and remove any scaling paint and rust before applying the membrane. NOTE When installing RESISTO MULTI- PURPOSE ALUMINUM WATERPROOFING, use a small hard roller to ensure good adherence.
11 20 ROOFS APPLYING RESISTO PRIMER Mix thoroughly before applying. Apply a coat of RESISTO PRIMER using a brush or roller. The surface must be clean and dry. Drying time ½ hour to 3 hours, depending on application conditions. The drying time can vary depending on the ambient temperature and the thickness applied, as well as the type of substrate. Coverage EXTERIOR PRIMER: 1 L covers 32 to 55 ft 2 (3 to 5 m 2 ) H 2 O PRIMER: 1 L covers 32 to 96 ft 2 (3 to 9 m 2 ) Coverage may vary depending on the permeability of the substrate The primer is dry when sticky but not messy when touched. On a rough surface (e.g., shingles), RESISTO ELASTOMERIC SEALER should be used to increase the adherence. NOTE: Primed surfaces may be slippery until the primer dries. Be careful when walking on the roof. TREATING ROOF DETAILS RESISTO PRIMER or SEALER, depending on the permeability of the surface, is required for this step. Vertical surfaces (walls, chimneys) Install a gusset (a small piece of membrane). Fig. ➌ ➐ Cut a strip of membrane to the required width. Apply the membrane to the roof and vertical surface, overlapping each by 4 in (10 cm). Always begin at the bottom of the detail to be protected (Fig. ➍ ➑) and end at the highest point. Fig. ➏ ➓ Use RESISTO ALU ELASTOMERIC SEALER to complete waterproofing. ROOFS 21 RESTORATION OF METAL ROOFS RESISTO ANTICORROSION SEALANT and the MULTIPURPOSE ALUMINUM WATERPROOFING are the perfect solution for restoring and repairing metal roofs. REQUIRED TOOLS: ➌ ➍ ➎ ➏ ➐ ➑ ➒ ➓ The ANTICORROSION SEALANT is a thick, homogeneous, SBS-modified, bitumen-based sealant containing aluminum pigments and solvents. It is used to restore metal surfaces and to protect them from corrosion. Offers effective protection for up to 10 years Is easy to apply and does not require primer Goes on easily with a brush, roller, or sprayer Is highly resistant to extreme weather, temperature fluctuations, and UV radiation Made of flexible elastomeric bitumen Lowers roof surface temperature Requires no special tools RECOMMENDED USES Metal roofs on farm buildings, factories, warehouses, mobile homes, campers. Metal surfaces ventilation equipment, reservoirs, trailers. (See the RESISTO «VARIOUS WATERPROOFING» guide for installation details) APPLICATION CONDITIONS The minimum application temperature is 32 F (0 C). It is important that products be brought to ambient temperature before use. SURFACE PREPARATION Inspect your roof and remove any scaling rust and paint. Repair open joints and cracks using RESISTO PRIMER and RESISTO MULTIPURPOSE ALUMINUM WATERPROOFING, which is available in different practical formats. RESISTO ANTICORROSION SEALANT can be applied to new, galvanized, or pre-painted steel surfaces. We recommend removing grease and oil, if any, using a solvent prior to applying the sealant. APPLYING RESISTO ANTICORROSION SEALANT Coverage: 1 litre covers 20 to 40 ft 2 (2 to 4 m 2 ). Coverage can vary depending on the protection desired and the condition of the surface. NOTE It is important to mix the sealant thoroughly, using a mixer tip, before use, and occasionally during use. Apply with a brush, long nap roller, or sprayer. The surface must be clean and dry. Let dry. Recommendations for using a sprayer We recommend using an Airless-type sprayer with a minimum pressure of 3,000 lb. Use a 50-foot-long (15 m), ¼-in-diameter hose. Use a 5:21 nozzle. The sealant can be diluted, as needed, with regular paint thinner such as xylene or Varsol. Do not dilute more than 1:10. NOTE (for sprayers only) : For a more aesthetic finish, the second coat must be thin. Dilute the sealant 1:4 with solvent. IMPORTANT : Clean the sprayer with regular paint thinner when finished. If a second coat is required, only apply once the first coat is completely dry (approx. 24 hours). RESISTO ANTICORROSION SEALANT can be applied to pre-painted surfaces. However, once it has been applied, it cannot be painted.
12 22 ROOFS ROOFS 23 INSTALLING RESISTOBOARD PANELS When installing RESISTOBOARD panels, stagger the vertical joints. The panels must be mechanically fastened using 1 in (2.5 cm) steel-washered roofing nails every 16 in (40 cm) as shown in the diagram below. 4 OTHER ROOFING PRODUCTS RESISTOBOARD RESISTOBOARD protection panels are the best solution for replacing damaged roof surfaces to provide a uniform substrate prior to installing a waterproofing membrane. RESISTOBOARD SEMI-RIGID PROTECTION BOARD 5 REQUIRED TOOLS PROFESSIONAL S PROFESSIONALS CHOICE THE and large headed nails SEMI-RIGID RESISTOBOARD PROTECTION PANELS are composed of a mineral-fortified asphaltic core between two asphaltsaturated fibreglass felts. RESISTOBOARD is designed to be used as a substrate material on low-slope roofs. It can be installed on wood surfaces, rigid insulation, or as a recover sheet on an existing roof surface that is to be re-roofed. RESISTOBOARD is also used as a protection panel in foundation waterproofing systems. Compatible with most modifiedbitumen and built-up roofing systems Easy to handle and install Mould resistant Puncture resistant Hard wearing Can be cut easily with a roofing knife
13 24 ROOFS ROOFS 25 INSTALLATION METHOD RESISTOR PLUS is attached to the roof using 1-in-diameter (2.5 cm) washered roofing nails (plastic or metal) spaced every 6 in (15 cm) in the centre and 1 in (2.5 cm) along the edge, with a repeat every 48 in (120 cm). (See the nailing pattern) NOTE Pneumatic staple guns are not recommended INSTALLING RESISTOR PLUS The roof surface should be clean before installing the RESISTOR PLUS underlayment. The surface must be smooth, with all sharp edges and protrusions repaired or removed, i.e., nails and staples. A dry surface is preferable to ensure superior performance and safety. RESISTOR PLUS should be installed with the printed side up, parallel to the gutters, beginning at the lower edge of the slope. Side joints must be overlapped by at least 4 in (10 cm) and end joints must be overlapped by at least 6 in (15 cm). Install strips of RESISTOR PLUS vertically along valleys and gables for improved protection. All vertical surfaces must be protected by strips of RESISTOR PLUS overlapped by 12 in (30 cm). Excess material can be trimmed later. RESISTOR PLUS contains a UV stabilizer but is not designed for prolonged exposure to strong UV radiation. Shingles or metal roofing must be installed as soon as possible after the RESISTOR PLUS underlayment. RESISTOR PLUS, as shown above, has a line pattern on the top surface to facilitate alignment of the underlayment. OTHER ROOFING PRODUCTS RESISTOR PLUS Synthetic, non-adhesive underlayment solution Quick and easy installation Excellent protection against extreme weather RESISTOR PLUS SYNTHETIC PROFESSIONAL S PROFESSIONALS CHOICE THE RESISTOR PLUS SYNTHETIC ROOF UNDERLAYMENT is a 18-mil-thick (0.456 mm) roof underlayment membrane composed of polyolefin. Strong and lightweight, RESISTOR PLUS is very slip resistant, wet or dry, winter or summer. Its UV resistant, anti-skid surface allows for fast, safe installation in any conditions. RESISTOR PLUS can even be installed in wintertime without losing any of its strength or flexibility. Is 9 time lighter than felt RESISTOR PLUS has 40 % greater nail pullout resistance that 30 lb felt Is hard-wearing Is easy to handle and install Has a line pattern on the surface to facilitate alignment Resists UV radiation (60 days exposure) Is slip resistant Is mould resistant Resists puncturing and tearing Repels water Withstands work crew traffic NAIL PATTERN NOTE: The drawing is not to scale as is intended for information purposes only. 4' 6" 3" 1" 9" 10" 3'- 4" 2' 1'- 8" 9"
14 26 ROOFS ROOFS 27 SURFACE PREPARATION The surface must be dry. Remove any loose particles or other substances that might interfere with adherence. On metal surfaces, remove grease and oil, if any, prior to applying the product. SUBSTRATE SBS modified bitumen membrane Concrete of fibrocement panels Wood and plywood Metal APPLYING RESISTOFLASH ADHESIVE Mix thoroughly before applying. Impregnate the surface to be prepared with adhesive using a brush or roller. Reinforce transitions and joints between two bases with RESISTOFLASH REINFORCEMENT membrane. Install immediately after the coat of RESISTOFLASH ADHESIVE. NOTES RESISTOFLASH ADHESIVE is designed to resist UV radiation and can remain unprotected. Do not spread more than 10 ft (3 m) at a time. APPLICATION AND CURING TIMES Once the RESISTOFLASH REINFORCEMENT has been installed, immediately cover with a first coat of RESISTOFLASH ADHESIVE. Cover the first coat with a second coat of RESISTOFLASH ADHESIVE after 2 to 3 hours. This curing time corresponds to the polymerization of RESISTOFLASH ADHESIVE at an ambient temperature of 68 F (20 C). Favourable conditions such as hot, humid, or windy weather can significantly reduce the curing time. OPTIONAL FINISHES Coloured granules: Small coloured granules can be spread on the last coat of RESISTOFLASH ADHESIVE while it is still wet. Use approximately 1.2 kg/m ². Spread the granules from bottom to top using a plastic trowel. The granules can also be added later by first spreading a thin coat of RESISTOFLASH ADHESIVE (250 g/m ² ) on the surface. Anticorrosion sealant: A coat of ANTICORROSION SEALANT (approx. 200 to 250 g/m²) can be applied to the surface for an aluminum finish. 1 Using a brush, roller, or spatula, apply a 4-in-wide (10 cm) coat of RESISTOFLASH ADHESIVE both horizontally and vertically at the bottom of the transitions between the roof and the upstands. Do not spread more than 10 ft (3 m) at a time. 2 Immediately install the RESISTOFLASH REINFORCEMENT on the wet adhesive using a spatula or brush. The reinforcement strips must overlap by at least 2 in (5 cm). 3 First waterproofing layer Immediately cover the RESISTOFLASH REINFORCEMENT and entire upstand with a coat of RESISTOFLASH ADHESIVE. Let dry 2 to 3 hours. 4 MATCHING FINISH FOR ROOF FLASHING RESISTOFLASH is a single-component waterproofing resin composed of bitumen and polyurethane. RESISTOFLASH is ready to use and is applied directly on traditional bituminous waterproofing, without primer. It is ideal for waterproofing upstands on new and repaired roofs. REQUIRED PRODUCTS RESISTOFLASH REINFORCEMENT RESISTOFLASH ADHESIVE GRANULES (if required) APPLICATION TEMPERATURE 41 F to 90 F (5 C to 35 C) RESISTOFLASH RESISTOFLASH REINFORCEMENT, RESISTOFLASH ADHESIVE and, if required, GRANULES, are the perfect solution for repairing cracks, holes, and open joints on roofs. REPAIRING HOLES AND CRACKS Long-lasting repairs of holes, cracks, and open joints Completely waterproof Easy and quick to install UV resistant Second waterproofing layer When the first coat is dry, complete the waterproofing by applying a finishing coat of RESISTOFLASH ADHESIVE, overlapping the first coat by approximately 1 in (3 cm).
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
Residential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
Peel & Seal Self-Stick Roofing Solutions
Peel & Seal Self-Stick Roofing Solutions Ideal for Low Slope Applications Waterproof and Weatherproof Energy Efficient Tough and Durable Versatile, Effective Sealing Around Protrusions Perfect for Vents,
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS
Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
Please read the entire document before purchasing and installing any of these products
Please read the entire document before purchasing and installing any of these products USA SBS UNDERLAYMENT ROOFING UNDERLAYMENT SBS Mineral Surfaced MINERAL SURFACE CAP SHEET Ice and Water Protection
Quality You Can Trust Since 1886... From North America s Largest Roofing Manufacturer
Quality You Can Trust Since 1886... From North America s Largest Roofing Manufacturer Leak Buster Repair & Maintenance Products Quality You Can Trust Since 1886...From North America s Largest Roofing Manufacturer
NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS
AC TOPSEAL SELF-ADHERED, GRANULAR SURFACED, SINGLE PLY, LOW SLOPE ROLLED ROOFING 3 X 33.3 = 100 SQ. FT. 10 YEAR MATERIAL LIMITED WARRANTY For Use on Porches / Sheds / Utility Buildings / Accessory Buildings
How to repair your existing low slope flat roof.
How to repair your existing low slope flat roof. Recycled Rubber Roofing is not a "Roof Coating." It is a liquid emulsion used as the underlayment of a new or retrofit, built-up roofing system. One of
HERITAGE WOODGATE LAMINATED ASPHALT SHINGLES Dallas, TX
Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES
BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES ABOUT POLYGLASS U.S.A., INC. MODIFIED CEMENTS & ADHESIVES MASTICS ALUMINUM COATINGS EMULSIONS & PRIMERS PROTECTIVE COATINGS Polyglass manufactures
BLACK JACK ALL WEATHER ROOF COATING
PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
Chapter 9: INSTALLING ROOFING
9.1 LEAK BARRIER (ICE AND WATER SHIELD) 9.2 SHINGLE UNDERLAYMENT 9.3 INSTALLING GUTTER APRON AND GABLE D-EDGE 9.4 INSTALLING SHINGLES 9.5 RIDGE VENT AND CAP Tools needed by each volunteer: Hammer (16 oz.
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. SMAA-2P-8xE UPGRADE SMOOTH SURFACE / CAP SHEET / SINGLE PLY 2 PLY POLYESTER REINFORCED ACRYLIC
Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.
Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that
SECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs
CertainTeed Self-Adhering Roof Systems for Low Slope Residential Roofs Goes down fast. Stays on strong. Flintlastic SA performs in all the right ways. What s more important to you? Speed of installation,
Installation Manual for STANDING SEAM ROOFING
Installation Manual for STANDING SEAM ROOFING Absolute Steel Toll Free 877-833-3237 / Phone 480-768-1618 / Fax 480-768-1514 www.metalroofingsource.com Standing Seam features approximately one-inch high
NRCA s steep-slope manual is thoroughly revised for 2013
Photo courtesy of Boone Brothers Roofing, Omaha, Neb. NRCA s steep-slope manual is thoroughly revised for 2013 by Maciek Rupar 38 www.professionalroofing.net MARCH 2013 P ublished in January, The NRCA
Shingle Installation Guide
Shingle Installation Guide Getting Started Dedicated to improving the environment, NewTech manufactures roofing tiles that are composed of up to 90% recycled post-industrial plastic. The manufacture of
Roofing Systems. New Applications / Re-Roofing / Maintenance
Roofing Systems New Applications / Re-Roofing / Maintenance New Roof Installation In terms of the design and installation of an original roofing system (in conjunction with the construction of a new building),
RECOATING AND RENEWING SPF ROOFING SYSTEMS
RECOATING AND RENEWING SPF ROOFING SYSTEMS Procedures, Regional Differences and type of coating systems Bruce Schenke Premium Spray Products REASONS TO RECOAT/RENEW Add a new coating layer to renew the
WATERPROOFING FOR CONCRETE STRUCTURES
MANUAL OF CONTRACT DOCUMENTS FOR ROAD WORKS VOLUME 1 SPECIFICATION FOR ROAD WORKS SERIES 2000 WATERPROOFING FOR CONCRETE STRUCTURES Contents Clause Title Page 2001 General 2 2002 Protection of Bridge Deck
METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES
METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES REFLECTICLEAN ACRYLIC/URETHANE Elastomeric Roofing Systems, Inc 6900 Bleck Dr. Rockford, MN 55373 800.403.7747 -or- 763.565.6900 fax: 763.565.6901 email:
Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..
Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
Epdm Flat Roofing Systems
Epdm Flat Roofing Systems EDPM can be fully bonded, loose laid and ballasted or mechanically attached depending on the existing roof and its proposed usage. This applies to roofs to be refurbished and
ATLAS Roofing Products
ATLAS Roll Roofing Products World s Largest producer of roofing s Preferred by roofing professionals. Atlas has you covered on every part of the job, even what goes under your roofing. We are proud to
Minor Cracks in Horizontal Surfaces
Cracks, chips and broken or flaking areas in concrete are not only unsightly, they can lead to further deterioration of the surface. The result is a costly replacement project as opposed to a simple repair.
Building Owners Guide to a Duro-Last System!
Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof
WATERPROOFING OF WET ROOMS
WATERPROOFING OF WET ROOMS Waterproofing under tiles For longterm enjoyment of a wetroom area a complete and resistant waterproofing system is an important precondition. Most tiles are by themselves waterproof
CREEK Technical Services, LLC
EVALUATION REPORT 2010 FLORIDA BUILDING CODE Manufacturer: Henry Company Report Issued February 20, 2013 999 North Sepulveda Blvd., Suite 800 El Segundo, CA 90245 (800) 486-1278 Manufacturing Plants: Quality
CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application 9 - 1 -
CONTENTS General conditions Material requirements 3 Terms 4 Estimating shingle requirements 4 Roof preparation 6 Shingle application 9 Shingle Shingle application application guide guide - - b a 3a 3b
SHINGLE APPLICATION GUIDE
SHINGLE APPLICATION GUIDE CONTENTS 01. General conditions 01. Material requirements 02. Terms 07. Estimating shingle requirements 08. Roof preparation 10.Shingle application E version 2006 GENERAL CONDITIONS
Detached accessory structures that contain no conditioned floor area are exempt.
RESIDENTIAL ROOFING PERMITS: A roofing permit is required for roofing of residential dwellings and garages in accordance with Section R105 of the International Residential Code. Updated 11/2013 City of
!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!
Table of Contents Section 1: Most Common Types of Flat Roofing Section 2: Better Understand Your Flat Roof Section 3: Flat Roofing Cost in 2015: Four Factors that Dictate Section 4: Planning A Flat Roofing
CHAPTER 6 ASPHALT ROLL ROOFING
CHAPTER 6 ASPHALT ROLL ROOFING Section I. DESCRIPTION AND GENERAL DISCUSSION 6.1.1 General 6.1.3 Mineral-Surfaced Asphalt roll roofing is roofing in sheet form Mineral-surfaced roll roofing is composed
Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems
Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems Introduction A complete range of Memtec Roofing and Waterproofing Single
Roof Systems Overview
Roof Systems Overview Cold Applied Built-Up Roofing Systems BURmastic Tremco s line of cold applied built-up roofing systems. BURmastic 200 Combines Tremco s expertise in asphalt blending technology with
Shingle Roofing: What s below the surface is important
What s below the surface is important The roof is leaking, the shingles look old, and the downspouts are dripping. It must be time to replace the roof or is it? Shingle roofs may seem simple, but a roof
Classic Products, Inc. ClickLock Standing Seam Installation Manual
Classic Products, Inc. ClickLock Standing Seam Installation Manual Classic Products, Inc. 8510 Industry Park Drive Piqua, OH 45356 800.543.8938 Table of Contents page Introduction 1. 1 Starter. 2. 1 Panels.
Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.
PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standing-seam metal roofing, custom fabricated. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Show installation
Colorado State University. Durrell Center Roof Repair
Colorado State University Durrell Center Roof Repair SPECIFICATION: POLYURETHANE FOAM ROOFING l.0 GENERAL REQUIREMENTS The successful application of a polyurethane foam roofing system is dependent upon
SEAMS SEAMING USING SEAM TAPE
SEAMING USING SEAM TAPE SEAMS The membrane should be positioned so that the width of the seam is 3. Remove excess chalk from a chalk line by snapping the line into the air and then chalk a line one-quarter
CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd
CI SfB (4-) Nn2 Onduline Mini Profile Onduline Garden Roof Range Onduline Building Products Ltd Onduline Garden Roof Range Onduline Mini Profile The new Onduline Mini Profile sheets have been designed
TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"
2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE
ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof
ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find
Low-slope reroofing guidelines
Low-slope reroofing guidelines by Thomas Bollnow and Joan P. Crowe, AIA The NRCA Roofing and Waterproofing Manual, Fifth Edition, contains reroofing guidelines for steep- and low-slope roofing. The August
We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION
07560 BUR BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION PART 1: GENERAL 1.01 SCOPE: To extend the useful service life of the aged or new asphalt built-up roof system and to reduce cooling
Rooflight INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary
Stormproof Your Roof. I ve done enough roof repairs to know that storm water that gets past the shingles
Stormproof Your Roof Self-adhering underlayment provides critical protection in vulnerable locations BY MIKE GUERTIN I ve done enough roof repairs to know that storm water that gets past the shingles and
Maintenance & repair Solutions
Maintenance & repair Solutions low-slope ROOFING We ve got what you need in the sizes you need them and the options to match the results that building owners want Seal-fast Temporary roof sealer Now you
NEOGARD. Preventive Maintenance Manual
NEOGARD Preventive Maintenance Manual Fluid-Applied Roof Coating Systems December 2014 Notes NEOGARD luid-applied roof coating systems are designed to be long lasting, monolithic membranes which provide
TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09
TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09 PMT GUIDE # 10 Book of Order Section G-10.0102o: "The session is responsible for the mission and government of the particular church. It
High Performance Solutions and Compounds for Roofing and Structural Waterproofing
High Performance Solutions and Compounds for Roofing and Structural Waterproofing IKO is a worldwide group of companies with extensive experience and specialist technical knowledge. IKO is a leader in
1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.
SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance
SECTION 07320 ROOFING TILE
SECTION 07320 ROOFING TILE PART 1 - GENERAL 1.1 SUMMARY: A. Section Includes: 1. Vitrified clay roofing tiles. 2. Tile accessories. 3. Felt underlayment. 4. Self-adhering sheet underlayment. 5. Snow guards.
SECTION 07550 - MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.
SECTION 07550 - PART I GENERAL 1.01 SECTION INCLUDES A. Vapor barrier (base ply); cover board at existing roof deck. B. Roof insulation at new roof deck. C. Modified bitumen membrane. D. Fluid applied
CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS
TITLE: STANDARDS FOR NEW ROOFING CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS Responsible Organization: Office of Facilities Planning Instructions: This Manual supersedes
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed
Although we do a fair amount of residential roofing, my family s breadand-butter. Installing a. Sealants aren t universal
Installing a Low-Slope Exposed EPDM for roof transition Exposed EPDM for resistance to ice damming Sidewall flashing Done with care, a flat roof can provide 0 years or more of leak-free service Gravel
Smooth cap sheet - 0-10 SQ $ 139.00. Smooth cap sheet - 11-50 SQ $ 63.00. Smooth cap sheet - 51-100 SQ $ 36.00 Smooth cap sheet - 101-200 SQ $ 36.
Demolition/Removal of Work 4-ply built up roofing to the insulation (smooth cap sheet) Smooth cap sheet - 0-10 SQ $ 63.00 Smooth cap sheet - 11-50 SQ $ 63.00 Smooth cap sheet - 51-100 SQ $ 35.00 Smooth
THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER
THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER DESCRIPTION TORCH OVER (15,17,19 YR) TH/BS-TH/CS 2 1 0 No 0. SUBSTRATE 1. THERMOTEK USA 2.0 FV TORCH SMOOTH 2. THERMOTEK USA PRO FP TORCH GRANULE COMPONENTS
ROOFS - Guidance for Repair, Maintenance and Replacement
ROOFS - Guidance for Repair, Maintenance and Replacement Guilford Association Architectural Committee ROOFING Slate and tile roofs are a critical design feature of Guilford homes. The homes were designed
Ruukki Finnera. The most intelligent roof ever seen.
Ruukki Finnera The most intelligent roof ever seen. Finnera s new and innovative design makes your steel roof not only beautiful but also extremely durable and practical. The revolutionary front-edge folding
HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION
HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION David Marut TEST CASE REPORT July 1, 2014 Case Study Pro Guard EPDM Super Coat Liquid Rubber Membrane Roof System
Solicitation DTFACN-11-R-00079 Attachment #9
These specs are only a general overview of the typical VOR Roof construction. These are for reference only. Each individual project will have its own specifications. 1 VOR Roof Projects IDIQ Solicitation
Your guide to home maintenance. Flat Roofs
Your guide to home maintenance Flat Roofs Your guide to home maintenance is a series of information leaflets that gives you all the information you need to keep your home in tiptop condition. Flat Roofs
CHAPTER 5 ASPHALT-SHINGLE ROOFING
CHAPTER 5 ASPHALT-SHINGLE ROOFING Section I. DESCRIPTION AND GENERAL DISCUSSION 5.1.1 References double-coverage shingles provide two layers over Specifications for shingles and allied materials are most
THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS
THERMOTEK SELF ADHESIVE MEMBRANE +G OVER DESCRIPTION SELF ADHESIVE OVER (8YR) BS-SA/CS 1 0 No 0. SUBSTRATE 1. BASE SHEET G FIBER GLASS BASE. THERMOTEK SELF ADHESIVE 3.0 FP GRANULE COMPONENTS AND WEIGHTS
STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries Introduction Wastewater of petrochemical industries and refineries contains high amounts of emulsified aliphatic or
THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE SYSTEM DESCRIPTION TORCH SYSTEM OVER POLYISO (15,17,19 YR) TH/BS-TH/CS
OPTIONAL TITLE 24 CRITICAL POINTS POLYISO THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE DESCRIPTION TORCH OVER POLYISO (5,7,9 YR) TH/BS-TH/CS 2 No 0. SUBSTRATE. THERMOTEK USA PRO 2.0 FV
COMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
How to Install Hardwood Flooring Over a Sub Floor
How to Install Hardwood Flooring Over a Sub Floor Installation Preparation Instructions Read the entire instructions before starting your project. 1) INSPECT EACH PLANK (see fig. a) Wood is a natural product
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,
After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE
86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements
Self-Stick Roofing Solutions
Peel & Seal Self-Stick Roofing Solutions Ideal for Low Slope Applications Waterproof and Weatherproof Energy Efficient Tough and Durable Versatile, Effective Sealing Around Protrusions Perfect for Vents,
INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles
INSTALLATION RECOMMENDATIONS Outdoor Rubber Tiles Prior to Installation: The Outdoor Rubber Tiles and accessory transition pieces intended for this installation have been shipped to you via a freight carrier
VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised
Page 1 of 6 instructions VC 104+ Rigid Grade / VC 104+ Rigid Grade Imagine / (for the rest of this document referred to as VC 104) can be applied to new and used trucks and trailers with painted rigid
ITEM 599.06060008 THERMOPLASTIC MEMBRANE ROOFING
DESCRIPTION Construct adhered membrane roofing system, roof insulation, and vapor retarder in accordance with these specifications. MATERIALS: General: Provide installed roofing membrane and base flashings
Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION
Sikadur-Combiflex REVISED JULY 2002 Sealing system for cracks and problem joints with large movements Construction DESCRIPTION USES ADVANTAGES The Sikadur-Combiflex joint sealing system consists of two
APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET
Environmental Protection and Growth Management Department PERMITTING, LICENSING AND CONSUMER PROTECTION DIVISION 1 N. University Drive, Box #302 Plantation, Florida 33324 954-765-4400 www.broward.org/permittingandlicensing
Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description
Product Data Sheet Edition 15/10/2014 Identification no: 02 07 04 10 300 0 000002 SikaProof A Edge SikaProof A-08 Edge, A-12 Edge Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry
A. This Section includes rubberized asphalt sheet membrane waterproofing systems.
SECTION 07110 SHEET MEMBRANE WATERPROOFING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
Seamless Waterproofing. Systems
Seamless Waterproofing Systems Pitched/Corrugated Roofs Liquid Rubber Instant Set is the ideal solution for pitched roof waterproofing providing a seamless fully bonded finish. RapidRoof is suited to smaller
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
Ubiflex. Non-lead flashing system
Ubiflex Non-lead flashing system Ubiflex non-lead flashing Ubiflex is a non-lead waterproof flashing material which can be used in most applications where lead is traditionally used to provide a weatherproof
Technology at its best. Benefits
Protecting what s under your roof from the elements is simplicity itself with Ruberoid Roofing Shingles. Roofing Shingles make ideal roofing; they are attractive, easy to install and are perfect for use
G VYCOR DECK PROTECTOR
G VYCOR DECK PROTECTOR Self-Adhered Flashing Contractor s Guide DECKS AND DETAIL AREAS For longer lasting decks, install Grace Vycor Deck Protector. FROM THE MAKERS OF G Ice & Water Shield What Self-Adhered