Including. Rubershield-Pro. Breather Membrane

Size: px
Start display at page:

Download "Including. Rubershield-Pro. Breather Membrane"

Transcription

1 Including RubershieldPro Breather Membrane

2 2 Ruberoid produces a wide range of underslating membranes, primarily to be installed below tiles, slates or metal roofing providing a secondary barrier against wind driven rain, snow and dust. Some like RubershieldPro, also allow the roof to breathe, negating the requirement for traditional ventilation, while other products perform specialist roles like eaves protection or securing overlap joints. This guide will help you choose your underslating materials and understand the other products needed to complete your project. Historically underslatings were hessian reinforced bitumen membranes. These are still available from Ruberoid together with other high performance polyester based bitumen underslatings. Although trusted for many years, they re unsuitable for modern warm roof or unventilated cold roof applications. Breather membranes are very popular and increasingly used on a wide range of projects. Their adaptable, multipurpose use is seen by specifiers, merchants and installers as the optimum solution to underslating requirements, simplifying design, stock control and installation requirements on site. WARM ROOFS Insulation following the rafter line COLD ROOF (VENTILATED VOID) Insulation at ceiling level COLD ROOF (UNVENTILATED VOID) Insulation at ceiling level RubershieldPro (laid over insulation) Vapour control layer Unventilated void space Insulation Underslating or RubershieldPro (laid over open rafters/sarking boards) Ventilated void space RubershieldPro (laid over open rafters) Unventilated void space Vapour control layer Vapour control layer

3 Breather membrane 3 Why RubershieldPro is the breather membrane of choice Today a new generation of underslating is available and most roofers have moved towards breather membranes such as RubershieldPro. A breather membrane allows potentially harmful moisture vapour to escape from within a building to the outside air, while remaining rain and waterresistant. One membrane suitable and approved for all types of roofing construction is a huge benefit, especially when it s also lightweight, easy to handle, strong and durable. RubershieldPro is a secondgeneration breather membrane, which conforms to the highest performance and professional standards. Designed as a fully supported or unsupported breathable underlay for tiled, slated or metal roofing systems, it s equally suitable whether draped unsupported over rafters or laid directly over insulation. The high vapour permeability and waterproof nature of this triplelayer engineered fabric, combined with its excellent tensile/tear strength and high wind uplift resistance, provides a permanent quality underlay for the life of the roof construction, making RubershieldPro the professional s ultimate choice. Additional features and benefits of RubershieldPro RubershieldPro is suitable and certified for use in all category types of pitched roof construction. Highly breathable so allows the escape of harmful moisture vapour Robust with high tensile and tear strength High wind uplift resistance Water and rain resistant Longterm durability Ideal for warm or cold roof applications (ventilated/unventilated) BBA Certification for all roof configurations Environmentally friendly no adhesives or toxic additives 100% recyclable

4 4 Typical warm roof construction Over the next few pages are some typical roof constructions. Detailed specifications and information on the full range of construction options are available from Ruberoid s Technical Services Department. What is a warm roof? Warm roofs are increasingly popular today as we aim to maximise our living space and the available accommodation in any construction. This will be the predominant form of pitched roofing construction in the UK. A breather membrane such as RubershieldPro must be used in a warm roof configuration, to overcome the condensation risk. In a warm roof configuration, the insulation is positioned directly under the external waterproofing (e.g. tiles or slates), following the rafter line. A vapour control layer is usually placed beneath the insulation (on the warm side), to limit the passage of moisture vapour into the insulation. The RubershieldPro breather membrane is placed on top of the insulation, with overlaps, penetrations and perimeters sealed with Rubershield Jointing Tape. Counter battens/tiling battens are used to install the tile or slate finishes. Using RubershieldPro there is no need to ventilate the void space below the breather membrane, as this void space will always be at a similar temperature to the habitable portion of the building, minimising the possibility for condensation. The void space that would have previously been a storage loft, is now a usable space. In addition, a warm roof contributes to increased airtightness, reducing heat loss by uncontrolled air movements, and aiding compliance with the revised Part L Building Regulations (April 2006). Using partial fill insulation between rafters When insulation is positioned between rafters but does not fill the whole rafter depth, an airspace must be maintained between the underside of Rubershield Pro membrane and the top of the insulation to allow a 1015mm drape of the membrane, unless 38mm counterbattens are used. Other requirements are as for when the insulation is laid above or fully filled between the rafters.

5 Typical warm roof construction 5 With rigid insulation boards, RubershieldPro membrane should be laid directly onto the insulation. Counterbattens (minimum 38mm deep) should be fixed according to insulation manufacturer s instructions. If insulation between rafters is full fill, the membrane should be laid directly over the rafters and insulation. Counterbattens (minimum 25mm deep) must be nailed directly into the rafters. A vapour control layer should be installed on the warm side of the insulation as detailed in BS 5250: 2002 Code of Practice for control of condensation in buildings. Using insulation board above and between rafters No ventilation of any void space is required below the RubershieldPro membrane. With clay or concrete tiles or natural slates, air movement is usually sufficient in the space above the membrane (below the tiles/slates) to negate the requirement for additional eaves and ridge ventilation. However, when using close fitting fabricated slates (e.g. fibre cement) additional eaves and ridge ventilation is recommended above the membrane. 50mm air space (ventilation may be required if using convection tight slates or tiles) Tiles Tiling battens Counterbattens RubershieldPro Insulation between rafters Vapour control layer Insulation positioned at rafter level with timber sarking As Scottish practice is for the use of timber sarking, which has a high resistance to the transmission of water vapour, it is advisable to conduct a condensation risk analysis. RubershieldPro fully complies with requirements in BS 5534: 2003 for use with sarking board installations. Where using proper timber sarking planks (usually 150mm wide) laid with a 2mm gap between the boards, there is no need to provide additional ventilation below the membrane. However, where using sarking boards comprising sheets of plywood or OSB, this type of warm unventilated roof configuration is not recommended. In a warm roof where the membrane is supported on a plywood or OSB sarking board, ventilation of the mandatory 50mm airspace below the sarking board is required, in accordance with BS 5534 (BS 5250: 2002). Under these circumstances there is no requirement for further ventilation above the membrane. Use of counterbattens above the membrane (installed on a sarking board) is required where tiles or slates are to be installed on battens. In some instances tiles or slates can be installed by nailing through the membrane directly into the sarking board. However, the tile manufacturer s instructions must be strictly adhered to.

6 6 Typical FIXING warm INSTRUCTIONS roof design details Some typical warm roof detailing examples are given here. Drawings should be used in conjunction with information available in Building Regulations and British Standards. Further advice, regarding the detailing of the RubershieldPro membrane is available from Ruberoid s Technical Services Department Eaves Ensure fascia board is fixed at correct height. Install Ruberoid Eaves Protection Strip.

7 Typical warm roof design details 7 Abutments Ensure ends of tiling battens are adequately supported on last counterbatten, install noggins if required. Turn RubershieldPro up against abutment wall by not less than 100mm and seal to wall with Rubershield Jointing Tape. Fix lead flashing Code 4 or 5, in accordance with current Codes of Practice and manufacturer s recommendations. Lay a continuous length of RubershieldPro, at least 600mm wide, up the valley. Fit valley support boards to a height level with top of counterbattens. Cut main layers of RubershieldPro to a rake down centreline of valley or along sides of valley lining. Valleys (with lead lining) Ridges Lay RubershieldPro over ridge by not less than 150mm.

8 8 Typical What cold is roof a cold design roof? details What is a cold roof? There are two main types of cold roof: A traditionally ventilated void space, where all types of underslating membranes can be used. An unventilated void space where only certain certified breather membranes can be used. A Cold Ventilated Void Roof configuration is the traditional form of pitched roof buildup. The insulation layer is placed horizontally, directly above the ceiling of the upper story of the habitable section of the building, usually positioned between the joists in the loft space. The RubershieldPro breather membrane or any type of proprietary underslating material is placed at rafter level, either draped between the rafters, or supported on a sarking board (usually Scotland). In a traditional cold roof system, any void space below the underslating membrane has to be ventilated. In this roof type, a breather membrane or nonbreathing underslating membrane would be equally suitable. When an underslating membrane is installed in a cold roof configuration draped between open rafters, the use of counterbattens is not required. In a Cold Unventilated Void Roof configuration the insulation layer is also placed horizontally, directly above the ceiling of the upper story of the habitable section of the building, with the vapour control layer placed below the insulation at ceiling level. However, in this situation, only a breather membrane certified for this configuration can be used. RubershieldPro breather membrane is approved for this purpose and should be placed at rafter level, with overlaps, penetrations and perimeters sealed with Rubershield Jointing Tape, draped between the rafters. However, there is no ventilation of any roof void space below the membrane; the only escape route for moisture vapour is through the breather membrane.

9 Typical What roof is a construction cold roof? 9 Use with sarking boards As Scottish practice where using tiling battens, RubershieldPro must be laid beneath counterbattens of a minimum 25mm depth. In some instances tiles or slates can be installed by nailing through the membrane directly into the sarking board. However, the tile manufacturer s instructions must be strictly adhered to. General guidance for cold ventilated roofs Where a roof underlay or breather membrane is to be laid over open rafters, a drape of between 10 to 15mm between the rafters is desirable to guide any rainwater penetrating the main roof finish away from the rafters to the drainage point. Provide for ventilation of the void space in accordance with BS 5534 (BS 5250: 2002), with the inclusion of a proprietary eaves and ridge (high level) vents, fixed in accordance with manufacturer s instructions. RubershieldPro and all Ruberoid underslating membranes fully comply with requirements in BS 5534: 2003, for use with sarking board installations in ventilated cold roof configurations. General guidance for cold unventilated roofs Where a roof underlay or breather membrane is to be laid over open rafters, a drape of between 10 to 15mm between the rafters is desirable to guide any rainwater penetrating the main roof finish away from the rafters to the drainage point. (The membrane must not be pulled tight against the underside of the tiling battens.) Using RubershieldPro in this type of cold roof requires no ventilation of any void space below the membrane. Also, when using clay or concrete tiles or natural slates, air movement is usually sufficient in the void space above the membrane to negate the requirement for additional eaves and ridge ventilation. However, when using manmade slates (or some close fitting interlocking tile systems) additional ventilation above the membrane in accordance with BS 5534: 2003 (BS 5250: 2002) is recommended to avoid potential damage to battens and fixings caused by condensation. It is recommended that guidance be sought from the tile or slate manufacturers concerned. To minimise the risk of condensation in cold unventilated roofs, all penetrations into the roof space must be properly sealed to maintain the integrity of the vapour control layer or external seal, and loft hatches should be made convection tight. All water tanks in the loft space must be covered and pipework lagged. The occupied building below must be ventilated in accordance with Building Regulations, and rooms that experience high humidity levels must have provision for separate air extraction. Use with sarking boards As Scottish practice, where using proper timber sarking planks (usually 150mm wide) laid with a 2mm gap between the boards, there is no need to provide additional ventilation below the membrane. However, where using sarking boards comprising sheets of plywood or OSB, this type of cold unventilated roof configuration is not recommended, and a traditional ventilated void approach should be adopted.

10 10 Typical cold roof design details Some typical cold roof detailing examples are given in this section. Drawings should be used in conjunction with Building Regulations and British Standards. Further advice regarding the detailing of RubershieldPro and underslating membranes in general is available from Ruberoid s Technical Services Department. For cold roofs with ventilated voids, all of the Ruberoid underslating membranes can be used. Eaves (with soffit): Ventilated voids Ensure fascia board is fixed at correct height. Install Ruberoid Eaves Protection Strip. Allow for eaves ventilation in accordance with BS 5250: 2002 Ensure ends of tiling battens are adequately supported on last counterbatten, install noggins if required. Turn Underslating up against abutment wall by not less than 100mm, and seal to wall with Rubershield Jointing Tape. Fix lead flashing Code 4 or 5, in accordance with current Codes of Practice and manufacturer s recommendations. Abutments: Ventilated voids Ridges: Ventilated voids Lay underslating over ridge by not less than 150mm. Allow for high level ventilation in accordance with BS 5250: 2002

11 Typical cold roof design details 11 Valleys (with lead lining): Ventilated voids Lay a continuous length of Underslating, at least 600mm wide, up the valley. Cut main layers of RubershieldPro to a rake down centreline of valley or along sides of valley lining. Cold roofs that are unventilated require the use of a breather membrane such as RubershieldPro. Ridges: Unventilated voids Lay RubershieldPro over ridge by not less than 150mm. If using tightly fitting slates or tiles, then counter battens should be used. Eaves (with soffit): Unventilated voids Ensure fascia board is fixed at correct height. Install Ruberoid Eaves Protection Strip. If using tightly fitting slates or tiles, then counter battens should be used.

12 12 Installation notes Sitework Underslating membranes must be installed in accordance with relevant sections of BS 5534: 2003, BS 8000: Part 6: 1990 and Ruberoid fixing instructions. Underslating materials are designed as a secondary barrier to wind driven rain and snow; it should not be considered a primary waterproofing layer. Good roofing practice dictates that the primary waterproofing finish (e.g. tiles, slates etc.) be applied as soon as practically possible. Whilst providing a degree of protection, underslating membranes should not be considered as a totally weatherproof protection for occupied buildings or where internal fitting out is taking place. With new buildings or buildings that have undergone extensive renovation that have involved wet trades, the additional water within the building during this first heating season, may cause condensation to form in the roof space, which cannot be fully dispersed by the breather membrane. However, when the internal conditions stabilise, this temporary occurrence of condensation will not recur in a properly designed and constructed system. (Additional information available in BS5250. Section 14.1 Owners Manual and NHBC guidance notes). Supporting structure An underslating membrane when installed as a fully supported system is laid over the support and secured with counterbattens. Alternatively, where practical, the membrane can be installed over counterbattens and fixed at 200mm centres using corrosionresistant straps or galvanised clout nails. Tiling battens are fixed to the counterbattens leaving an airspace between the roof sheet underlay and the tiles for drainage and ventilation. Abutments Abutment flashings should be wedged into a mortar joint 25mm deep and at least 150mm above the level of the slates or tiles. Underslating membranes should be turned up behind the flashing at least 100mm, and sealed where appropriate with Rubershield Jointing Tape to prevent rain and snow being blown into the roofspace, and to restrict unwanted air movement. Lap sizes table horizontal and vertical laps Roof pitch Min. horizontal lap partially supported (mm) Min. horizontal lap fully supported (mm) Min. vertical lap (mm) and greater Notes to lap sizes table Reinforcing strips of 600mm minimum should be fixed at hips, ridges and valleys. It is recommended that where underslating is to be dressed into a half round external gutter, Ruberoid Eaves Protection Strip should be utilised in this area. Note as with all breather membranes of this type, contact with solvents or wet timber preservatives can cause localised water penetration to occur prior to the main weatherproofing being installed.

13 RubershieldPro 13 Typical uses of RubershieldPro Breather Membrane RubershieldPro breather membrane is ideal for all types of warm and cold roof constructions. It can be used as: 1. Roofing underlay positioned immediately above the insulation layer in a warm pitched roof below the roof finish, or in a cold pitched roof (ventilated or unventilated). 2. Roofing underlay for use under tiles and sheeted roofs, over open rafters or onto fully boarded substrates. 3. Breather membrane for timber frame wall construction or behind hanging tiles, timber boarding or cladding systems. Other RubershieldPro applications Hanging tiles Masonry cladding Low slope metal roofs

14 14 Ruberoid pitched roof protection range RoofGuardSB Spunbonded polypropylene, high performance nonbituminous underslating. Starex Polyester based, high performance bituminous underslating. Zylex Hessian reinforced, traditional bitumen underslating to BS 747 Type 1F. Ruberoid Eaves Protection Strip In conjunction with the underslating membrane, an eaves protection strip should be used to give lasting protection where the underslating dresses into external gutters. It can be used with any underslating material (including breather membranes), any tile or slate finish and in cold or warm roof configurations. Main uses Used where dressing any roof underlay into an external gutter. Rubershield Jointing Tape When using breather membranes, Rubershield Jointing Tape is also helpful to allow the individual sheets of membrane to be sealed to each other and at detail work, improving waterproofing performance and the airtightness of the installation. A high performance doublesided selfadhesive tape, protected by a silicon release film on both sides. It is applied between the overlap and at perimeter details/roof penetration points in RubershieldPro and other polypropylene membranes to effectively seal the joints. Rubershield Jointing Tape can make a considerable contribution to a roof complying with Part L of Building Regulations by effectively limiting unwanted air movement and improving thermal performance. Main uses Sealing all lap joints in RubershieldPro breather membranes. Attaching RubershieldPro to other surfaces (e.g. brickwork). Sealing the membrane at penetration points (e.g. soil vent pipes). Rubershield Pro RoofGuard SB Starex Zylex Ruberoid Eaves Protection Strip Length and width (m) Warm pitched roof Cold pitched roof (unventilated void) 50 x x x x x x x x 0.33 Cold pitched roof (ventilated void) Eaves protection (dressing into external gutter) Approval/standard BBA Cert. No. 05/4228 BS 747 1F BS 747 5U *Conforms to NHBC Technical Standards * * *

15 RubershieldPro 15 Environmental considerations RubershieldPro is manufactured from 100% polypropylene, bonded together without the use of adhesives. This allows RubershieldPro to be completely recyclable. Health and Safety A Health and Safety data sheet relating to Ruberoid underslating membranes can be downloaded from the Ruberoid web site or alternatively obtained from the Technical Services Department. Compliance with standards RubershieldPro conforms to the following requirements: BS 5250: 2002 (Code of Practice for control of condensation in buildings) Complies with NHBC technical requirements Fully covered for all applications by a current BBA BS 5534: 2003 (Code of Practice for slating and tiling) certificate. BS 5250: 2002 defines a vapour permeable pitched roof underlay as complying with the requirements BS 5534: 2003 and being vapour permeable with a vapour resistance less than 0.25MNs/g. RubershieldPro complies fully with this requirement, and is classified as an LR (low resistance) underlay in accordance with BS 5250: 2002, with a vapour resistance of 0.13MNs/g. Pitched roof buildups usually fall into 3 primary categories: warm roofs, cold roofs (ventilated void), cold roofs (unventilated void), as detailed in British Standards BS 5534 and BS Durability & guarantee RubershieldPro is covered by BBA certificate 05/4228 which identifies that the product will be virtually unaffected by the normal conditions found in a roof space. Correctly installed, RubershieldPro will effectively last the design life of the slate or tiled roof into which it is incorporated. Under these circumstances the effective product guarantee will be the same as for the main tile or slate roof covering utilised. Composition and appearance A triple layer highly breathable weatherproof membrane, made from high tensile spunbonded polypropylene layers around a microporous polypropylene film, bonded together by ultrasonic lamination. The outer layer forms the functional weatherproof surface, the middle layer is the breathable waterproof membrane, and the inner layer protects the membrane from abrasion and damage, also giving additional strength. This enables the fabric to allow moisture vapour to pass through, whilst providing high levels of water protection. RubershieldPro has a green upper surface, printed with the trade name, easy cut grid pattern and head lap lines. The underside is white. Roll width (m) Roll length (m) Roll area (m 2 ) Roll weight (kg) Weight (g/m 2 ) Performance Tensile strength MD 288 (N/50mm) to TD 275 BS EN 12311: 2000 Elongation (%) to MD 78 BS EN 12311: 2000 TD 83 Nail tear strength (N) to MD 168 BS EN 12311: 2000 TD 185 Water vapour transmission (g/m2/24 hrs) to BS 3177 >1500 Resistance to water pressure to moat Pass (6 m/ 24 hours) Mullen burst (kpa) 790 Fire rating to DIN 4102, B2 Pass UV resistance 4 months Wind uplift (at 343mm batten spacing to Appendix 2.25kPa G Standard 90/13286

16 Technical & design enquiries Tel: Fax: Ruberoid Building Products Customer Services Appley Lane North, Appley Bridge, Wigan, Lancashire WN6 9AB Tel: Fax: Whilst every care is taken to see that the information given in this literature is correct and uptodate it is not intended to form part of any contract or give rise to any collateral liability, which is hereby specifically excluded. Intending purchasers of our materials should therefore verify with the company whether any changes in our specification or application details or otherwise have taken place since this literature was issued.

Roofers Guide to Underslating Membranes

Roofers Guide to Underslating Membranes Roofers Guide to Underslating Membranes IKO is a worldwide enterprise, with more than 3000 employees, and manufacturing plants in Canada, the United States, United Kingdom, Belgium, Holland, France and

More information

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance

More information

ROOFERS CHOICE BREATHER MEMBRANES FOR USE IN COLD NON-VENTILATED ROOFS

ROOFERS CHOICE BREATHER MEMBRANES FOR USE IN COLD NON-VENTILATED ROOFS Mercury Building Products Ltd 114 Eckington Road Coal Aston Dronfield Sheffield S18 3AY Tel: 01246 292816 Fax: 01246 292867 e-mail: sales@vaprfree.co.uk danny@vaprfree.co.uk website: www.mercurybuildingproducts.com

More information

MONARPERM 600, MONARPERM PLUS AND MONARPERM TOP (COLD VENTILATED AND WARM NON-VENTILATED)

MONARPERM 600, MONARPERM PLUS AND MONARPERM TOP (COLD VENTILATED AND WARM NON-VENTILATED) Icopal Limited Barton Dock Road Stretford Manchester M32 0YL Tel: 0161 865 4444 Fax: 0161 866 9859 e-mail: info.uk@icopal.com website: www.icopal.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

PROVIDING PROTECTION IN CONSTRUCTION Technical guide: roofs. www.tyvek.co.uk www.construction.tyvek.com

PROVIDING PROTECTION IN CONSTRUCTION Technical guide: roofs. www.tyvek.co.uk www.construction.tyvek.com PROVIDING PROTECTION IN CONSTRUCTION Technical guide: roofs www.tyvek.co.uk www.construction.tyvek.com DuPont TM membranes Providing protection Contents Page Introduction............................................................................................................................

More information

I n s u l a t i o n. Low Energy Low Carbon Buildings

I n s u l a t i o n. Low Energy Low Carbon Buildings I n s u l a t i o n CI/Sfb (47) Ln6 Sixth Issue March 2011 BREATHABLE MEMBRANE FOR UNVENTILATED PITCHED ROOFS AND TIMBER FRAME WALLS Waterproof can be used as a temporary roof covering Non tenting Airtight

More information

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

CHESTERFLEX ROOF WATERPROOFING MEMBRANES CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED

More information

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades Construction Sika For Sealing and Waterproofing Construction Gaps in Building Façades Waterproof and Airtight Flexible Seal Controlled Vapour Diffusion Bonds to any Building Substrate Prevents Interstitial

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

INSULATED PITCHED ROOFING

INSULATED PITCHED ROOFING DOW CONSTRUCTION PRODUCTS (a division of the Dow Chemical Company Ltd) INSULATED PITCHED ROOFING Welcome to this RIBA approved CPD self tutorial. First some information about the Dow Chemical Company itself:

More information

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02

More information

Ubiflex. Non-lead flashing system

Ubiflex. Non-lead flashing system Ubiflex Non-lead flashing system Ubiflex non-lead flashing Ubiflex is a non-lead waterproof flashing material which can be used in most applications where lead is traditionally used to provide a weatherproof

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035 Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí

More information

AND MEMBRANES ROOFING UNDERLAYS. www.fakro.com

AND MEMBRANES ROOFING UNDERLAYS. www.fakro.com AND MEMBRANES 010 ROOFING UNDERLAYS 1 HO DOES YOUR ROOF BREATHe? MEMBRANES THE WAY to A WARM AND DRY ROOF HO HO HO HO HO HO WATERTIGHTNESS The FAKRO Company offers a wide range of membranes and underlays

More information

Technology at its best. Benefits

Technology at its best. Benefits Protecting what s under your roof from the elements is simplicity itself with Ruberoid Roofing Shingles. Roofing Shingles make ideal roofing; they are attractive, easy to install and are perfect for use

More information

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description Product Data Sheet Edition 15/10/2014 Identification no: 02 07 04 10 300 0 000002 SikaProof A Edge SikaProof A-08 Edge, A-12 Edge Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing

More information

The formation of roof waterproofing details calls for

The formation of roof waterproofing details calls for 3.5 BUILT-UP ROOFING DETAIL DESIGN INTRODUCTION The formation of roof details calls for a combination of the skills of the designer and the roofer. There are many different approaches to detail design

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

SANS 1 0 1 7 7-9. www.spunchem.com FIRE PERFORMANCE SANS 428 ENERGY SAVER REFLECTIVE TIASA A MEMBER OF 2009/366 2009/367 2009/369 2008/341

SANS 1 0 1 7 7-9. www.spunchem.com FIRE PERFORMANCE SANS 428 ENERGY SAVER REFLECTIVE TIASA A MEMBER OF 2009/366 2009/367 2009/369 2008/341 REFLECTIVE ENERGY SAVER FIRE PERFORMANCE SANS 428 SANS 1 0 1 7 7-9 SANS 10177-10 SANS 10177-11 www.spunchem.com A MEMBER OF TIASA Thermal Insulation Association of Southern Africa 2009/66 2009/67 2009/69

More information

Cupa Natural Slate Roofing design and fixing guide

Cupa Natural Slate Roofing design and fixing guide Cupa Natural Slate Roofing design and fixing guide Cupa Natural Slate synonymous with quality Currently the Spanish slate industry is the undisputed market leader in natural slate production, with 90%

More information

Bituminous Sheet Flat Roofs: Their repair and maintenance

Bituminous Sheet Flat Roofs: Their repair and maintenance Bituminous Sheet Flat Roofs: Their repair and maintenance Flat roof covered in sheets of bituminous felt Introduction Whilst flat roofs are often regarded as inferior to their pitched counterparts and

More information

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the

More information

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,

More information

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5 Accredited Construction Details (Scotland) 2010 For the limitation of thermal bridging and air infiltration in low and medium rise domestic buildings Introduction & Principles Issued in support of Junction

More information

Part 7 Roofs. Chapter 7.2. Pitched roofs. Effective from 1 January 2012

Part 7 Roofs. Chapter 7.2. Pitched roofs. Effective from 1 January 2012 Part 7 Roofs Chapter Effective from 1 January 2012 CONTENTS SCOPE DESIGN Clause Page Design standards D1 1 Statutory requirements D2 1 Loadbearing structure D3-D4 1 Trussed rafter roofs D5 1 Traditional

More information

Under Tile and Slate Undersheeting System

Under Tile and Slate Undersheeting System CI Sf (4-) Nn2 Under Tile and Slate Undersheeting System One system providing a weatherproof barrier, ventilation and insulation A RITISH OARD OF AGREMENT CERTIFICATE NO. 94 / 3055 2 Under Roofing System

More information

Rockwool Flexi Insulation Application Guide

Rockwool Flexi Insulation Application Guide Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed

More information

FUNCTIONAL REQUIREMENTS

FUNCTIONAL REQUIREMENTS FUNCTIONAL REQUIREMENTS FUNCTIONAL REQUIREMENTS 7.9 ROOF COVERINGS TRADITIONAL SLATE AND TILES Workmanship i. All workmanship must be within the tolerances defined in Chapter 1 of this Manual. ii. All

More information

Residential Roofing Guide

Residential Roofing Guide Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...

More information

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Fourth Issue March 2011 TR21 INSULATION FOR FLAT ROOFS WATERPROOFED WITH PARTIALLY BONDED BUILT UP FELT AND MASTIC ASPHALT High performance rigid thermoset insulation

More information

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,

More information

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced

More information

ICOPAL POUR AND ROLL ROOF WATERPROOFING ICOPAL POWER ELASTOMERIC ROOF WATERPROOFING SYSTEM

ICOPAL POUR AND ROLL ROOF WATERPROOFING ICOPAL POWER ELASTOMERIC ROOF WATERPROOFING SYSTEM Icopal Limited Barton Dock Road Stretford Manchester M32 0YL Tel: 0161-865 4444 Fax: 0161-864 8433 e-mail: market.uk@icopal.com website: www.icopal.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing Good Craftsmanship Guide Carpentry and Joinery- Carcassing Introduction This Good Craftsmanship Guide highlights key problems with the major elements of Carpentry and Joinery - Carcassing, and gives guidance

More information

BLACK JACK ALL WEATHER ROOF COATING

BLACK JACK ALL WEATHER ROOF COATING PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.

More information

REDLAND DRY BONDING GUTTER. Installation Instructions for Redland Dry Bonding Gutter

REDLAND DRY BONDING GUTTER. Installation Instructions for Redland Dry Bonding Gutter REDLAND DRY BONDING GUTTER Installation Instructions for Redland Dry Bonding Gutter 1 Introduction 1.1 TECHNICAL DATA Dimensions: 3 m long x 210 mm wide Material: Glass-fibre/polyester composite. Pitch

More information

House building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors

House building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors W42_Stand_Extra_32 15/3/05 9:17 am Page 2 NHBC s technical newsletter April 2005 Issue 32 This edition includes: 2 House building is changing fast NHBC unveils new Standards Chapters on curtain walling

More information

Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture

Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture Rochdale Building Control Guide Approved Document C Site preparation and resistance to contaminants and moisture Dampness is often misdiagnosed within buildings, the approved document deals with prevention

More information

CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application 9 - 1 -

CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application 9 - 1 - CONTENTS General conditions Material requirements 3 Terms 4 Estimating shingle requirements 4 Roof preparation 6 Shingle application 9 Shingle Shingle application application guide guide - - b a 3a 3b

More information

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

ALUMASC ROOF WATERPROOFING MEMBRANES EUROROOF MASTERGOLD ROOF WATERPROOFING MEMBRANE

ALUMASC ROOF WATERPROOFING MEMBRANES EUROROOF MASTERGOLD ROOF WATERPROOFING MEMBRANE Alumasc Exterior Building Products Ltd White House Works Bold Road Sutton St Helens Merseyside WA9 4JG Tel: 01744 648 400 e-mail: roofing@alumasc-exteriors.co.uk website: www.alumascroofing.co.uk APPROVAL

More information

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6

More information

Providing protection in construction

Providing protection in construction Providing protection in construction VOLUME 2: WALLS AND FLOORS Contact Information UK office address: DuPont Tyvek Hither Green Trading Estate Clevedon, North Somerset BS21 6XU Tel: 01275 879770 Fax (sales):

More information

Steel-framed Walls. Insulation

Steel-framed Walls. Insulation Insulation A4/8 SF AW1192 Issue 4 Nov 2012 Steel-framed Walls Insulation guide Helps achieve a 6-star house energy rating Rigid and flexible Kingspan AIR-CELL solutions available Vapour barrier or vapourpermeable

More information

ROOFS, SNOW AND ICE DAMS

ROOFS, SNOW AND ICE DAMS ROOFS, SNOW AND ICE DAMS The Problem Ice dams are a common roof performance problem in cold climate buildings. Simply put, they are ridges of ice and icicles caused by melt water from further up the roof

More information

Building Regulations for the Conservation of Fuel and Power

Building Regulations for the Conservation of Fuel and Power Insulation CI/SfB Rn7 M2 First Issue April 2014 Building Regulations for the Conservation of Fuel and Power ENGLAND EXISTING DWELLINGS 2013 EDITION Low Energy Low Carbon Buildings Contents Page Introduction

More information

ROOFING. Introduction

ROOFING. Introduction 1 Introduction The lifetime of a building begins with the choice of materials and for hundreds of years, architects and designers have been inspired by the natural beauty of slate. Through its aesthetic

More information

THE REDLAND GUIDE TO BS 5534

THE REDLAND GUIDE TO BS 5534 THE REDLAND GUIDE TO BS 5534 HELPING YOUR COMPANY TO GET ONE STEP AHEAD www.redland.co.uk Enforcement is via authorities such as the National House Building Council (NHBC) and Local Authority Building

More information

Low Energy Low Carbon Buildings

Low Energy Low Carbon Buildings I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Eighth Issue March 2011 TR27 LPC/FM INSULATION FOR FLAT ROOFS WATERPROOFED WITH FULLY ADHERED SINGLE PLY, PARTIALLY BONDED BUILT UP FELT, MASTIC ASPHALT AND COLD

More information

Monarflex Vapour Control Layers

Monarflex Vapour Control Layers Monarflex Vapour ontrol Layers I/Sf 27.2 May 2008 N6 The simple and cost effective way to reduce air leakage, maximise thermal performance and prevent harmful condensation. High performance VL s designed

More information

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side

More information

CI/SfB (Ff3) January 2011. Roofing design guide. Showing you the way. Redefining traditional products

CI/SfB (Ff3) January 2011. Roofing design guide. Showing you the way. Redefining traditional products CI/SfB (Ff3) January 2011 Roofing design guide Showing you the way Redefining traditional products Contents 2-3 General information Eaves detailing 4 Traditional eave 4 Hardrow slates eave Verge detailing

More information

Innovation - High performance roof, wall and floor insulation board. delivering better performance

Innovation - High performance roof, wall and floor insulation board. delivering better performance 2010 VERSION 1 IRL High performance roof, wall and floor insulation board Innovation - delivering better performance PRODUCT SPECIFICATION INSTALLATION GUIDE I ve worked with Xtratherm for years, they

More information

SIKA TANKING MEMBRANES SIKAPROOF A MEMBRANES

SIKA TANKING MEMBRANES SIKAPROOF A MEMBRANES Sika Limited Watchmead Welwyn Garden City Hertfordshire AL7 1BQ Tel: 01707 394 444 Fax: 01707 329 129 e-mail: technical@uk.sika.com website: www.sika.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Final inspections are completed by site visit only. Access to fenced yards shall be planned. ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,

More information

Cl/SfB (13.9) a comprehensive. technical guide. to the specification of. vapour control layers. www.proctorgroup.com GROUP LTD

Cl/SfB (13.9) a comprehensive. technical guide. to the specification of. vapour control layers. www.proctorgroup.com GROUP LTD Cl/SfB (13.9) Ln6 a comprehensive technical guide to the specification of vapour control layers..the knowledge to produce solutions GROUP LTD www.proctorgroup.com Partnerships in action THE PROBLEM GROUP

More information

NRCA s steep-slope manual is thoroughly revised for 2013

NRCA s steep-slope manual is thoroughly revised for 2013 Photo courtesy of Boone Brothers Roofing, Omaha, Neb. NRCA s steep-slope manual is thoroughly revised for 2013 by Maciek Rupar 38 www.professionalroofing.net MARCH 2013 P ublished in January, The NRCA

More information

Section 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane

Section 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane Section Flat Roofs Warm deck single ply membrane Product: Rocksilk Krimpact Flat Roof Slab Fl01 Warm deck single ply membrane Product: Polyfoam ECO Roofboard Fl02 Warm deck built-up felt/ mastic asphalt

More information

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY CI/SfB Oct 12 (47) Ln Uniclass L524 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY Bailey Flame-free felt roofing Bailey

More information

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find

More information

BAUDER BITUMINOUS ROOFING SYSTEMS BAUDERFLEX ROOF WATERPROOFING SYSTEMS

BAUDER BITUMINOUS ROOFING SYSTEMS BAUDERFLEX ROOF WATERPROOFING SYSTEMS Bauder Ltd 70 Landseer Road Ipswich Suffolk IP3 0DH Tel: 01473 257671 Fax 01473 230761 e-mail: mail@bauder.co.uk website: www.bauder.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

The Kingspan Insulation Price List 1 st January 2013

The Kingspan Insulation Price List 1 st January 2013 Insulation The Kingspan Insulation Price List 1 st January 2013 FOR BUILDING FABRIC INSULATION, CAVITY CLOSERS AND MEMBRANES Visit our website: www.kingspaninsulation.co.uk Low Energy - Low Carbon Buildings

More information

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES Building and Construction Industry A joint industry initiative produced by BSA Supershow logo.indd 1 30/01/2008 9:43:29 AM EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES FAILING WATERPROOFING

More information

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems Introduction A complete range of Memtec Roofing and Waterproofing Single

More information

0845 0098 980 www.nicholsonsts.com

0845 0098 980 www.nicholsonsts.com 0845 0098 980 www.nicholsonsts.com ROOFTRAK The IFP is revolutionising the way we fix things to roofs. Technical Director of a leading UK roofing system manufacturer The ROOFTRAK-IFP A revolutionary solution

More information

LANGLEY S ROOF WATERPROOFING MEMBRANES PARADIENE/PARAFOR ROOF WATERPROOFING SYSTEMS

LANGLEY S ROOF WATERPROOFING MEMBRANES PARADIENE/PARAFOR ROOF WATERPROOFING SYSTEMS Langley Waterproofing Systems Ltd Bishop Crewe House North Street Daventry Northants NN11 4GH Tel: 01327 704778 Fax: 01327 704845 e-mail: enquiries@langley.co.uk website: www.langley.co.uk APPROVAL INSPECTION

More information

VM ZINC : standing seam Guidelines for specification and installation

VM ZINC : standing seam Guidelines for specification and installation VM ZINC : standing seam Guidelines for specification and installation Junglim Architecture - QUARTZ-ZINC Roofing and cladding system in VM ZINC Roofs from a 3 pitch and facades Freedom with shape and appearance

More information

Wraptite THE AIRTIGHT AND VAPOUR PERMEABLE MEMBRANE

Wraptite THE AIRTIGHT AND VAPOUR PERMEABLE MEMBRANE Wraptite THE AIRTIGHT AND VAPOUR PERMEABLE MEMBRANE The A. Proctor Group Ltd, a familyowned company in its fourth generation, has been providing solutions and products to the construction industry for

More information

Triflex system: Triflex ProDetail. Solution type: Roof detail and repair waterproofing. Application: Overlay of existing substrate

Triflex system: Triflex ProDetail. Solution type: Roof detail and repair waterproofing. Application: Overlay of existing substrate CAD details Triflex ProDetail Triflex system: Triflex ProDetail Solution type: Roof detail and repair waterproofing Application: Overlay of existing substrate CAD details CAD S: CAD details Triflex ProDetail

More information

The assessment is described in the following pages which form integral parts of this certificate, which should be read in its entirety.

The assessment is described in the following pages which form integral parts of this certificate, which should be read in its entirety. Cl/SfB (13.1) Ly (L2) BRE CERTIFICATION LTD CERTIFICATE OF ASSESSMENT PRODUCT Powerbase RB 340 and RB 370 Radon Resistant Membranes CERTICATE NO. 100/03 ISSUED: MARCH 03 REISSUED: NOVEMBER 07 SUPPLIED

More information

TP10. Insulation RAFTER LEVEL INSULATION FOR TILED OR SLATED PITCHED WARM ROOF SPACES BBA BRITISH

TP10. Insulation RAFTER LEVEL INSULATION FOR TILED OR SLATED PITCHED WARM ROOF SPACES BBA BRITISH Insulation CI/Sfb (27.9) Rn7 M2 Fifth Issue May 2007 TP10 RAFTER LEVEL INSULATION FOR TILED OR SLATED PITCHED WARM ROOF SPACES High performance rigid urethane insulation thermal conductivity 0.023 W/m.K

More information

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd CI SfB (4-) Nn2 Onduline Mini Profile Onduline Garden Roof Range Onduline Building Products Ltd Onduline Garden Roof Range Onduline Mini Profile The new Onduline Mini Profile sheets have been designed

More information

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet

More information

Regulations Detail Sheet 1

Regulations Detail Sheet 1 Designated by Government to issue European Technical Approvals Esha (UK) Ltd Esha House St Mary s Business Park Albany Road Market Harborough Leicestershire LE16 7EB Tel: 01858 410372 Fax: 01858 410572

More information

When considering Roof drainage design the following should be taken into account:

When considering Roof drainage design the following should be taken into account: Roof Drainage Design The primary objective of a gutter or spouting system is to remove water from the roof catchment area and channel that water to the ground drainage. Water ingress can have detrimental

More information

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX TECHNICAL CHARACTERISTICS Multi-Foil Reflective Insulation Xfoil Range of insulation is designed to achieve

More information

Low Energy Low Carbon Buildings

Low Energy Low Carbon Buildings I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Seventh Issue March 2011 TR26 LPC/FM INSULATION FOR FLAT ROOFS WATERPROOFED WITH MECHANICALLY FIXED SINGLE PLY WATERPROOFING High performance rigid thermoset insulation

More information

Glidevale offers a complete range

Glidevale offers a complete range CI/SfB (13.9) Uniclass Ss_32_20_30_48 June 2016 Glidevale offers a complete range of protection for ground floors against both damp and gases from the ground. This double function avoids the need for a

More information

Epdm Flat Roofing Systems

Epdm Flat Roofing Systems Epdm Flat Roofing Systems EDPM can be fully bonded, loose laid and ballasted or mechanically attached depending on the existing roof and its proposed usage. This applies to roofs to be refurbished and

More information

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight

More information

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37 Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details

More information

DENSO WATERPROOFING SYSTEMS

DENSO WATERPROOFING SYSTEMS DENSO WATERPROOFING SYSTEMS Approved Quality Management System AS/NZS ISO 9001:2008 Lloyds Register Certificate N o Mel 0927759 Denso (Australia) Pty Ltd A MEMBER OF WINN & COALES INTERNATIONAL 411 413

More information

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength. INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal

More information

CI/SfB (4-) Rf9 January 2016. Dry fix and ventilation systems including UNIVERSAL accessories. Roofing product catalogue 45

CI/SfB (4-) Rf9 January 2016. Dry fix and ventilation systems including UNIVERSAL accessories. Roofing product catalogue 45 CI/SfB (4-) Rf9 January 2016 Dry fix and ventilation systems including UNIVERSAL accessories Roofing product catalogue 45 Today s roofs need to be weatherproof and look good, as well as providing adequate

More information

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING

More information

SHINGLE APPLICATION GUIDE

SHINGLE APPLICATION GUIDE SHINGLE APPLICATION GUIDE CONTENTS 01. General conditions 01. Material requirements 02. Terms 07. Estimating shingle requirements 08. Roof preparation 10.Shingle application E version 2006 GENERAL CONDITIONS

More information

Please read the entire document before purchasing and installing any of these products

Please read the entire document before purchasing and installing any of these products Please read the entire document before purchasing and installing any of these products USA SBS UNDERLAYMENT ROOFING UNDERLAYMENT SBS Mineral Surfaced MINERAL SURFACE CAP SHEET Ice and Water Protection

More information

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November 2013. l Water and water vapour barrier. l Factory controlled thickness

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November 2013. l Water and water vapour barrier. l Factory controlled thickness CI/SfB TN6 L6813 November 2013 RIW SHEETSEAL 226 is a cold applied, high density polyethylene film, coated with a bitumen/rubber self adhesive layer with a removable reinforced silicone paper. Primer is

More information

TR31. I n s u l a t i o n. Low Energy Low Carbon Buildings

TR31. I n s u l a t i o n. Low Energy Low Carbon Buildings I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Sixth Issue March 2011 TR31 STRUCTURAL INSULATION / FSC CERTIFIED PLYWOOD COMPOSITE FOR FLAT ROOFS WATERPROOFED WITH PARTIALLY BONDED BUILT UP FELT High performance

More information

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions. In Townsville s climate it is essential to choose building materials that perform well in our local conditions. Choosing the correct materials and insulation will improve the overall thermal performance

More information

FLAT ROOF INSULATION INSULATION ROOFING FLAT. Quick Guide. Quick Guide. Insulation. EcoTherm Insulation UK Sales Team. Insulation

FLAT ROOF INSULATION INSULATION ROOFING FLAT. Quick Guide. Quick Guide. Insulation. EcoTherm Insulation UK Sales Team. Insulation Insulation Insulation Scotland & North England 07824 412579 North West & North Wales 07931 342948 South Wales & West Midlands 07940 546247 Yorkshire & East Midlands 07825 570100 FLAT ROOF INSULATION EcoTherm

More information

WATERPROOFING FOR CONCRETE STRUCTURES

WATERPROOFING FOR CONCRETE STRUCTURES MANUAL OF CONTRACT DOCUMENTS FOR ROAD WORKS VOLUME 1 SPECIFICATION FOR ROAD WORKS SERIES 2000 WATERPROOFING FOR CONCRETE STRUCTURES Contents Clause Title Page 2001 General 2 2002 Protection of Bridge Deck

More information

FATRA ROOF COVERING SYSTEMS FATRAFOL FF807 AND FATRAFOL FF807/V ROOF COVERING SYSTEMS

FATRA ROOF COVERING SYSTEMS FATRAFOL FF807 AND FATRAFOL FF807/V ROOF COVERING SYSTEMS Fatra UK Ltd Unit 12 The Timber Yard East Moors Road Ocean Park Cardiff CF24 5EE Tel: 029 2048 7954 Fax: 029 2048 9226 e-mail: sales@fatra.co.uk website: www.fatra.co.uk FATRA ROOF COVERING SYSTEMS APPROVAL

More information

How To Build A Gambrel Roof And A Gable End Roof

How To Build A Gambrel Roof And A Gable End Roof Dutch Gable or Gambrel Roof and The Scotch Valley The folowing pages are an extract from Carp 12 text TAFE NSW Construction and Transport Division 71 HIP and VALLEY ROOFING GAMBREL / DUTCH GABLE The effect

More information

Abstract. 2. Cold Pitched Roofs

Abstract. 2. Cold Pitched Roofs Heat and moisture transport between houses and cold lofts - a combination of convection and diffusion Emannuel Essah and Chris Sanders Glasgow Caledonian University Abstract About 80% of domestic pitched

More information

Specialist vapour diffusion torch-on membrane Wentylacyjny Werner PYE PV250 S54 is used to make new roofs as well as renovate old ones.

Specialist vapour diffusion torch-on membrane Wentylacyjny Werner PYE PV250 S54 is used to make new roofs as well as renovate old ones. Catalogue 2013 Diffusion roofing membranes Main purpose of the vapour diffusion roofing membranes is to waterproof the roof but they also possess ventilation function allowing water excess to escape from

More information

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the

More information