Cabling recommendations for DS-6 intercom and PA/GA systems

Similar documents
DS-6 Intercom System Introduction

Specification SFTP CAT6 Network Cable 23AWG CU

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

Networks. The two main network types are: Peer networks

Gulf Cable & Electrical Ind. Co.

Standard Buccaneer - Ethernet

HARAX circular connector

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

Communication, Signal & Data Cables

with coloured cores and overall copper screen UL/CSA... 17

WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

HARTING Ethernet Cabling 4-poles Overview

COAX Cables Radio Frequency Cables

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

EVOline Multimedia Modules

SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

6000 Series Buccaneer

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

Outdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof

INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

Network Design. Yiannos Mylonas

Flexible and safe solutions, for decades. Cables for alarmand safety systems

Fault location on power cables. Fault location on power cables

HARTING Ethernet Cabling 8-poles Overview

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Commercial Coaxial Cable

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

ETHERLINE Ethernet Cable, Connectors & Tools

Copper Cables CONNECTIVITY & CABLING SYSTEM

HARTING econ 3000 Introduction and features

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

LIFE-LINE Safety Cables Continuous Bending Hi-Flex Electrical Cables to Guarantee Safe Cable & Hose Carrier Systems

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Rack mounted telephone- and leased line modem for industrial applications

Flexible cables for submersible products

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

If you want to get an official version of this User Network Interface Specification, please order it by sending your request to:

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

Structured Cabling, Earthing & Equipotential Bonding

coaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable

ALARMLINE ANALOGUE Linear Heat Detection System

We hope that every customer sets up CC-Link system easily by reading this documentation.

HARTING Ethernet Cabling 4-poles Overview

Ethernet Patch Cord Wiring

CAVEL VS80205 MADE IN ITALY 1000 V

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Telephone- and leased line modem for industrial applications TD-36

428 MY HOME Structured cabling system for the home sector

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Comm5 Wiring Installation

Cable Solutions for Servo and Variable Frequency Drives (VFD)

CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

Computers Are Your Future Prentice-Hall, Inc.

C 060 CCTV Coaxial Cable

HARTING Ethernet Cabling 4-poles Overview

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Global cable expertise for rolling stock

Frequently Asked Questions

Configuration RJ-45 (IEC ) 6-7. Categories and NEW terms EN , ISO/IEC De-embedded Re-embedded 14-15

< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10

Screened cable and data cable segregation

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Good EMC Design Principles: cable routing

6 ELECTRICAL PARAMETERS

400 Series - Mini USB Buccaneer

The Quality Connection. BETAflam Fire Resistant Safety Cables

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

Inductive sensor NI10-M18-Y1X-H1141

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

Festoon 715 P PUR cable for flexible application in festoon systems

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

Security & Surveillance Cabling Systems

Outside Telephone Cable

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

Video Camera Installation Guide

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

MICROCABLES. A complete vision of your connectivity needs. Catalogue

INTERNATIONAL STANDARD

Signal directionality Lower frequency signals are omnidirectional Higher frequency signals can be focused in a directional beam

MYTHBUSTING Takes on Shielded Cabling

TECHNICAL SPECIFICATION

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES

Flexible Control Cables

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Nexus Technology Review -- Exhibit A

Industrial circular connectors

International Electrotechnical Commission Standards

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Transcription:

Cabling recommendations for DS-6 intercom and PA/GA systems Configuration + Service PC Call station MTSD DS-6 digital WF AK analogue WFA / WFA-Ex analogue WFD / WFD-Ex digital DS-6 node DS-6 Panel-mounted call station Gate intercom analogue Actuators Sensors Loudspeaker WFD/WFD-Ex with dial pad Bearb./Edit: Ripholz 16 4 0001 507 Seite/page 1 von/of 9 2011 ms NEUMANN ELEKTRONIK GMBH

PREFACE The cabling recommendations from ms Neumann Elektronik refer to the current generally applicable standards. Furthermore, company specific regulations and guidelines from regional standards have to be considered. Contents 1. General 2. Applicable standards and documents 3. Cabling scheme 4. Cables for call stations 4.1 Basic characteristics of the installation cables to use 4.1.1 Installation instructions 4.2 Terms and cable construction according to DIN VDE 0815 and DIN VDE 0816 4.2.1 Wire 4.2.2 Pair 4.2.3 Star quad 4.2.4 Basic bundle with star quad 4.2.5 Bundle with pairs 4.3 Installation cables for applications within a building according to DIN VDE 0815 4.4 Installation cables for outdoor applications according to DIN VDE 0816 4.5 Installation cables with reinforcement according to EN 60079-14 4.6 Structured cabling in IP networks 5. Cable for loudspeakers 5.1 Maximum cable length with 10% voltage loss (-1dB) at telecommunication lines 5.2 Maximum cable length with 10% voltage loss (-1dB) at power lines Bearb./Edit: Ripholz 16 4 0001 507 Seite/page 2 von/of 9 2011 ms NEUMANN ELEKTRONIK GMBH

1. General Cabling of DS-6 systems from ms Neumann Elektronik is an important part of our safety concept. By using standardised cables with the same line quality and line condition, statements concerning the distances and the transmission characteristics can be made. Outside of the netnode, normal telecommunication cables are required for analogue and digital ISDN terminals as well as for modem transmission lines. IP terminals are strictly connected to the netnode according to the standard structured cabling EN 50173. 2. Applicable standards and documents - ms Neumann Elektronik document No. 033 0009 999 Distances of the call stations from ms Neumann Elektronik - VDE 0100 respectively IEC 364 Erection of power installations with nominal voltages up to 1000 V - VDE 0165 respectively EN 60079-14 Electrical installations in hazardous areas - IEC / EN 60079-.Ex-protection classes - VDE 0800 respectively EN 50310 Telecommunications - VDE 0815 respectively DIN EN 50441 Wiring cables for telecommunication and data processing systems - VDE 0816 External cables for telecommunication systems - DIN EN 50173 and ISO/IEC 11801 and EIA/TIA 568 Structured cabling - DIN 15905-2 Electro-acoustics used for theatre stages and for multi-purpose halls Wiring systems for sound purposes 3. Cabling scheme To get the maximum safety and availability of the DS-6 systems from ms Neumann Elektronik, the terminals and loudspeakers are connected to the different netnodes by the shortest route. Generally, the power supply of the terminals is provided by the netnodes. Bearb./Edit: Ripholz 16 4 0001 507 Seite/page 3 von/of 9 2011 ms NEUMANN ELEKTRONIK GMBH

Example: Modem Netnode Uk0 adapter Analogue adapter 1 TP, 2km 1 TP, 2km 1 TP 1 TP 2 TP 3 TP 5 TP 4 TP 1 TP Analogue adapter Existing analogue PA - system TP= Twisted Pair 2 TP for longer distances The number of wires for analogue call stations results as follows: - 2 wires for a/b - 2 wires for power supply - 1 6 wires for lines For a call station with 6 lines, 10 wires respectively 5 TP are required. The number of wires for digital call stations with Uk0 interfaces results as follows: - 2 wires for data transmission with phantom power - 2 additional wires for the power supply of an additional amplifier 4. Cables and distances for call stations according to the drawing No. 033 0009 999 4.1 Basic characteristics of the installation cables to use - copper wires optional 0,4-0,6-0,8-0,9 mm - twisted pair wires or star quad stranding - shielding of the whole cable (aluminium foil) 4.1.1 Installation instructions Cables for terminals outside of the netnode must not be laid directly beside high voltage cables, power cables or cables with a high HF rate. Bearb./Edit: Ripholz 16 4 0001 507 Seite/page 4 von/of 9 2011 ms NEUMANN ELEKTRONIK GMBH

4.2 Terms and cable constructions according to DIN VDE 0815 and DIN VDE 0816 4.2.1 Wire A wire is a copper conductor with insulating cover. 4.2.2 Pair A pair consists of two stranded wires building a loop. a b 4.2.3 Star quad A star quad consists of 4 stranded wires, of which in each case two diametrically opposing wires loop (pair). One pair is also named as twisted pair (TP). a a b b Pair 1 Pair 2 4.2.4 Basic bundle with star quad One basic bundle consists of 5 combined star quads. 4.2.5 Bundle with pairs One bundle with pairs consists of 4 combined pairs. Bearb./Edit: Ripholz 16 4 0001 507 Seite/page 5 von/of 9 2011 ms NEUMANN ELEKTRONIK GMBH

4.3 Installation cables for applications within a building according to DIN VDE 0815 Example: J-Y(ST)Y 4x2x0,8 J Installation cable Y PVC insulating cover (ST) static screen 4x2x08: 4 pair each 2x0,8 mm Cables for fire protected areas have to be halogen-free. In case of fire, the duration of functional integrity of electrical cable systems has to be at least 30 minutes (E30). This applies to systems for alerting and giving instructions to visitors and employees, if these systems have to be active in case of fire. PVC outer sheath Static screen: Aluminium foil plastic coated with CU - tracer wire Plastic foil Stranding type: twisted pair Core insulation: PVC Conductor: bare copper wire 4.4. Installation cables for outdoor applications according to DIN VDE 0816 Example: A-2Y(L)2Y 5x4x0,8 A Outdoor cable 2Y PE insulating cover (4) Layer coat 5x2x08: 5 star quads each 2x0,8 mm Outdoor sheath: Polyethylene enhanced in layers Static screen: Aluminium foil plastic coated with CU tracer wire Plastic foil - Stranding type: star quad Core insulation: Polyethylene Conductor: bare copper wire Bearb./Edit: Ripholz 16 4 0001 507 Seite/page 6 von/of 9 2011 ms NEUMANN ELEKTRONIK GMBH

4.5 Installation cables with reinforcement according to EN 60079-14 Example: A-2YYBC 8x2x0,8 LG A Outdoor cable 2Y PE insulating cover Y PVC insulating cover B Reinforcement C Protective coating of jute and viscous mass 8x2x08: 8 pairs each 2x0,8 mm LG Stranding in layers In heavy environments it is required to use cables with reinforcement (EN 60079-14). The reinforcement is used for an increased protection, but it can also be used simultaneously as shielding. A potential equalisation by the reinforcement must not be carried out. That means that the reinforcement as electrical shield may only be connected to earth on one side. The reinforcement ends at the call station in a plastic screw. 4.6 Structured cabling in IP networks DS-6 systems from ms Neumann Elektronik are designed for the use of IP networks. All IP terminal connections meet the regulations of structured cabling according to DIN EN 50173 Class D. Class D = Standard designation for symmetrical copper cabling up to 100MHz operating frequency = Twisted Pair cable Class D The maximum cable length between a switch in the netnode and the terminal must not exceed 100 m. If longer distances should be bridged, modems are used, which allows distances up to 2000 m by a normal 2-wire telecommunication cable. FO modems can also be used for bridging distances, of course. For further information concerning spacious cabling, please see the standard DIN EN 50173. Example indication of the manufacturer for installation cable: 4x2x AWG 24 SF-UTP e 100 MHz suitable for structured building cabling 4x2 4 twisted pairs AWG24 Wire diameter 0,5mm (AWG = Coding for bare CU wire derived from inch size. SF Braid and foil screen as overall screen UTP Unshielded Twisted Pair e Category 5 guarantees 100 MHz Bearb./Edit: Ripholz 16 4 0001 507 Seite/page 7 von/of 9 2011 ms NEUMANN ELEKTRONIK GMBH

Fig. installation cable Twisted, cross lead and isolated pairs Aluminium foil Copper braid Plastic sheathing 5. Cables for loudspeakers Our PA concepts base in the power range on the 100 V transmission technology. In case of using and cabling of the 100 V loudspeaker cables the standard DIN VDE 0800 is applicable. Basically, telecommunication cables should be used for cabling of the loudspeakers. We recommend use of shielded twisted pairs. The following wire diameters are used: 0,6 mm, 0,8 mm and 0,9 mm. Here, a sufficient proof voltage is important. Also a sufficient wire size shall be provided. If systems are used for alerting purposes, the attenuation must not be audible. Therefore, the wire sizes are calculated so that the voltage losses are then 10% (recommendation of ZVEI, see also standard DIN 15905-2). If a telecommunication cable is used as a loudspeaker line, all other wire pairs must not be used for other types of communication like e.g. telephony or audio signal transmitting. In case of higher power, power lines can also be used. But the cable must not contain a green yellow wire (protective earth). The wires should be pair-twisted so that high crosstalk attenuation can be achieved. Independently of these recommendations, the legal specifications and standards have to be considered in the operation area. Bearb./Edit: Ripholz 16 4 0001 507 Seite/page 8 von/of 9 2011 ms NEUMANN ELEKTRONIK GMBH

5.1 Maximum cable length with 10% voltage loss (-1dB) at telecommunication lines 1000 Cable length dimensions 1) 2) 3) 1) 0,6mm, 2) 0,8mm, 3) 0,9mm C able len gth / m 900 800 700 600 500 400 300 200 100 0,6 mm 0,8 mm 0,9 mm 0 0 25 50 75 100 125 150 175 200 225 250 Loudspeaker power / W 5.2 Maximum cable length with 10% voltage loss (-1dB) at power lines 4) 1,5 mm² 5) 2,5 mm² 6) 4 mm² max. distance for loudspeaker impedance measurement: 1000 m Cable length / m 4000 3500 3000 2500 2000 1500 1000 500 4), 5), 6) Cable length dimensions 0 0 25 50 75 100 125 150 175 200 225 250 Loudspeaker power / W Bearb./Edit: Ripholz 16 4 0001 507 Seite/page 9 von/of 9 2011 ms NEUMANN ELEKTRONIK GMBH