KNX/EIB DALI gateway Plus. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

Similar documents
1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Mounting and operating instructions. Surface-mounted hands-free feature home station

Product and functional description

DALI RC BASIC SO. Control unit Operating instructions

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

Mounting and Operating Instructions. TV gateway

Tebis KNX Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 131

How To Use A Power Supply On A Powerline 2.2 (Ai)

Operating instructions IV / 2007

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus KNX SA/S Switch Actuators Product Manual

Highly flexible the right KNX/DALI gateway for every requirement

ABB i-bus KNX DALI-Gateway DG/S 8.1

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Residual current socket 30mA Order No.:

KNX Lighting Control System

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Operating instructions II / 2004

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

Operating instructions

ABB i-bus EIB Logic Module LM/S 1.1

Operating instructions. RCD flat 4-fold, 6-fold

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

DMX2PWM 9 Channel Dimmer Setup Manual

Quick Connect. quick - simple - efficient.

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S Intelligent Installation Systems ABB

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

DALIX PROGRAMMING MANUAL. Gateway KNX-DALI V1.0 TECHNICAL SUPPORT. Tel (+34)

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

ABB i-bus KNX DALI Gateway Emergency Lighting DGN/S Product Manual

ABB i-bus KNX Switch Actuators SA/S Product Information

Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI

Operating Instructions. Keypad

ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

ABB i-bus KNX Switch Actuators SA/S Product Information

Application Unit, MDRC AB/S 1.1, GH Q R0111

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

User Manual THR840DUK Digital Thermostat

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

INSTALLATION & SERVICE MANUAL. Display Panel

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M ES/M , ES/M

Installation and Operating Instructions

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Installation and Operation Back-UPS 1250, 1300, 1500

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

instabus KNX / EIB System System E F G H

PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP )

connecdim Gateway G1 Ethernet TCP/IP to DALI

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

2013 Wireless Video Intercom INSTALLATION GUIDE

Inwall 4 Input / 4 Output Module

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Back-UPS Pro 1300/1500 Installation and Operation

EIB/KNX IP Interface with Power over Ethernet (PoE)

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

PHOENIX CONTACT Features

Push button 3gang standard flush-mounted xx

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS

Safety technique. Emergency stop module BO 5988 safemaster

Application software. Fan coil actuator 2gang RMD. Electrical / Mechanical characteristics : see product information

Drayton Digistat +2RF/+3RF

KNX R. Rain Sensor. Installation and Adjustment

ADM1TE 5/30A DIN rail single phase two wire energy meter

mecotron Safety relay ESTOP-2 For emergency stop monitoring

ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB.

5SV Residual Current Protective Devices

User s Manual Before using the inverter, you need to read and save the safety instructions.

basicdim DGC Compact control module

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Electric Rotary Actuator - On/Off or programmable control actuator

KNX Powerline PL 110. KNX Association

Modular I/O System Analog and Digital Interface Modules

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

TIG INVERTER INSTRUCTION MANUAL

Digital input modules

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

13 SERIES. Electronic step relays A

Transcription:

Order No. : 2180 00 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please read and follow manual fully. Danger of electric shock. Always disconnect before carrying out work on the devise or load. At the same time, take into account all circuit breakers that supply dangerous voltage to the device or load. Danger of electric shock. Device is not suitable for disconnection from supply voltage. The DALI control voltage is a functional extra-low voltage (FELV). On installing, ensure safe isolation between KNX and DALI. These instructions are an integral part of the product, and must remain with the end customer. 2 Device components Figure 1 (1) Button field for manual operation (2) Programming button and LEDs (3) KNX connection (4) Display of DALI devices or DALI group (5) Connection for mains supply (6) DALI output 3 Function System information This device is a product of the KNX system and complies with the KNX directives. Detailed technical knowledge obtained in KNX training courses is a prerequisite to proper understanding. 32587002 10285511 07.08.2013 1/9

The function of this device depends upon the software. Detailed information on loadable software and attainable functionality as well as the software itself can be obtained from the manufacturer s product database. Planning, installation and commissioning of the device are carried out with the aid of KNXcertified software. Full functionality with KNX commissioning software version ETS3.0f onwards. An updated version of the product database, technical descriptions and conversion programs and other auxiliary programs are available on our Internet website. Intended use - Controlling of luminaires and other applications with DALI operating device in KNX installations e.g. electronic ballast - Installation on DIN rail according to EN 60715 in distribution boxes Product characteristics - Control of up to 64 DALI devices in up to 32 groups - Individual, group or central addressing - Suitable for operation in emergency lighting systems - 16 light scenes - Effect control for dynamic lighting effects or colour games - Read out DALI device state via KNX, e.g. brightness or luminaire error - Manual operation of the DALI groups - Restraint - Feedback of switching state and brightness value in bus and manual mode - Collective feedback - Central switching function - Disabling function for each DALI group - Separate ON and OFF delay - Staircase lighting timer with run-on time - Corridor function: when combined with motion detectors, reduced continuous lighting, if no motion is detected - Online or offline project planning of the DALI devices with ETS plug-in - Short circuit protection - Surge protection - Overload protection - Operating hours counter - Signal of the global switching status of the DALI devices, e.g. to switch off the mains voltage of the DALI devices to avoid standby losses - An individual DALI device can be exchanged during operation without software. i Delivery state: construction site mode, the DALI groups can be operated using button field. All DALI devices are controlled jointly. 32587002 10285511 07.08.2013 2/9

4 Operation Operating elements Figure 2 (4) Display of DALI number (1...64) (4a) DALI group (4b) Individual DALI devices (7) Button c Manual operation (8) LED c On: Continuous manual mode active (9) ON/nbutton switch on or increase brightness (10) LED ON/n On: DALI device or group switched on, brightness 1...100 % (11) OFF/o button switch off or reduce brightness (12) LED OFF/o On: DALI device or group switched off, brightness 0 % (13) ALL OFF button Switch off all DALI devices In operation with the button field the device distinguishes between a short and a long press. - Short: pressing for less than 1 second - Long: Pressing for between 1 and 5 seconds Operating modes - Bus operation: Operation via push-button sensors or other bus devices - Short-term manual operation: Manual operation locally with button field, automatic return to bus operation. - Continuous manual mode: Exclusively manual operation on the device i No bus operation is possible in manual mode. i No manual mode is possible in case of bus failure. i After a bus failure and restoration the device switches to bus operation. i After a power failure and restoration the device switches to bus operation. i The manual mode can be disabled in ongoing operation via a bus telegram. Switching on the temporary manual control Operation using the button field is programmed and not disabled. o Press the c button briefly. Display (4) shows 01, LED c remains off. - or - 32587002 10285511 07.08.2013 3/9

Display (4) shows bc: all connected DALI devices are controlled jointly. i After 5 seconds without a button-press, the device returns automatically to bus operation. Switching off temporary manual operation The device is in short-term manual mode. o No button-press for 5 seconds. - or - o Press c button briefly as many time as necessary until the device leaves the short-time manual mode. The display (4) is off. Switching on permanent manual control Operation using the button field is programmed and not disabled. o Press the c button for at least 5 seconds. LED c is illuminated, display (4) shows 01, continuous manual mode is switched on. - or - Display (4) shows bc: all connected DALI devices are controlled jointly. Switching off permanent manual control The device is in continuous manual mode. o Press the c button for at least 5 seconds. LED c is off, display (4) is off, bus operation is switched on. Operating DALI devices The device is in continuous or short-term manual mode. o Press c button briefly as many times as necessary until the display shows the desired DALI number. The LEDs ON/n and OFF/o indicate the status. o Operate output with ON/n or OFF/o button. Short: switch on/off. Long: dim brighter/darker. Release: Stop dimming. The LEDs ON/n and OFF/o indicate the status. i Short-term manual operation: after running through all of the available DALI numbers, the device exits manual mode after another brief press. i The display (4) firstly shows the numbers of the available DALI groups (4a), followed by the individual addresses of the DALI devices (4b). Switch off all DALI devices The device is in continuous manual mode. o Press the ALL OFF button. All DALI devices switch off. Disabling individual DALI devices or groups The device is in continuous manual mode. o Press c button briefly as many times as necessary until the display shows the desired DALI number. Status display via LEDs ON/n and OFF/o. o Press ON/n and OFF/o buttons simultaneously for at least 5 seconds. The selected DALI number flashes in the display (4). DALI device or group is blocked. o Activate bus mode (see section Deactivating permanent manual control). i DALI devices blocked via manual operation can be operated in manual mode. 32587002 10285511 07.08.2013 4/9

Unblocking a DALI device or group The device is in continuous manual mode. o Press c button briefly as many times as necessary until the display (4) flashes the desired DALI number. o Press ON/n and OFF/o buttons simultaneously for at least 5 seconds. DALI device or group is enabled. The display (4) no longer flashes. o Activate bus mode (see section Deactivating permanent manual control). 5 Information for electrically skilled persons 5.1 Fitting and electrical connection DANGER! Electrical shock when live parts are touched. Electrical shocks can be fatal. Before carrying out work on the device or load, disengage all the corresponding circuit breakers. Cover up live parts in the working environment. Fitting the device Observe the temperature range. Ensure adequate cooling. o Mount device on DIN rail. Output terminals must be at the top. Connecting the device Figure 3 Control cable: appropriate type, cross-section and routing for the specifications for 250 V cables. DALI and mains voltage wires can be run together in a cable, e.g. NYM 5x1.5 mm². i DALI participants from some manufacturers have expanded functions and can e.g. be controlled via mains voltage on the DALI connection. When existing DALI installations are refitted, remove all corresponding operator controls. i The DALI control voltage is a functional extra-low voltage (FELV). When performing installation, perform the installation in such a way that when an area is disconnected the lines carrying both the DALI and also the mains voltage are disconnected. o Connect device as shown in the connection example (Figure 3). 32587002 10285511 07.08.2013 5/9

o If multiple miniature circuit breakers supply dangerous voltages to the device or load, couple the miniature circuit breakers or label them with a warning, to ensure disconnection is guaranteed. o Connect bus line with connecting terminal. i DALI devices can be connected to various phase conductors. Operation in emergency lighting systems The device can be used in decentrally-powered or in centrally-powered emergency lighting systems. In decentrally-powered emergency light systems, emergency luminaires with individual batteries and special DALI devices are used. i Observe the number of DALI devices in the emergency luminaires used. Emergency lighting systems with a central safety supply are required in buildings larger than 2000 m². Depending on the scope of functions of the system, only the emergency luminaires are supplied by the central safety supply (Figure 4), or the KNX system and DALI gateway are also supplied (Figure 5). In the latter case, in emergency operation, the DALI gateway can transmit the appropriate fault messages to a central system and other DALI gateways in the system. Figure 4: Emergency luminaires supplied through a central safety supply Figure 5: Emergency luminaires, KNX system and DALI gateway supplied through a central safety supply Installing the cover It is necessary to install a cover to protect the bus connection against hazardous voltages in the connection area. 32587002 10285511 07.08.2013 6/9

Figure 6: Installing the cover o Route the bus line towards the rear. o Install cover on top of the bus terminal so that it snaps into place (Figure 6). Removing the cover Figure 7: Removing the cover o Press the cover to the side and pull it off (Figure 7). 5.2 Commissioning Load the address and the application software o Switch on mains voltage. o Switch on the bus voltage. o Assign physical address and note on the device label. o Commission DALI system using commissioning software. i For more detailed information on commissioning of the DALI system, see the technical product information for this device. o Load the application software into the device. i No programming is possible if no mains voltage is connected. 32587002 10285511 07.08.2013 7/9

6 Appendix 6.1 Technical data Supply Rated voltage AC 110... 240 V ~ Mains frequency 50 / 60 Hz Rated voltage DC DC 110... 240 V Power loss max. 3 W Ambient conditions Ambient temperature -5... +45 C Storage/transport temperature -25... +70 C DALI DALI rated voltage DC 16 V (typical) Number of DALI subscribers max. 64 DALI transmission rate 1.2 kbit/s DALI protocol EN 62386 Cable type Sheathed cable 230 V, e,g. NYM DALI cable length with Ø 1.5 mm² max. 300 m with Ø 1.0 mm² max. 238 m with Ø 0.75 mm² max. 174 m with Ø 0.5 mm² max. 116 m Housing Fitting width 72 mm / 4 modules Connection of power supply and DALI Connection mode Screw terminal single stranded 0.5... 4 mm² finely stranded without conductor sleeve 0.5... 4 mm² finely stranded with conductor sleeve 0.5... 2.5 mm² KNX KNX medium TP 1 Commissioning mode S-mode Rated voltage KNX DC 21... 32 V SELV Power consumption KNX typical 150 mw Connection type for bus Connection terminal 6.2 Troubleshooting Display shows "Er", connected DALI devices have no function, no operation possible Cause: Mains voltage on DALI cable. Installation error. Disconnect device and connected DALI devices from mains voltage and disconnect bus voltage. Correct installation. Display shows "bc" in manual mode, control of individual luminaires not possible. Cause: The device has not been programmed or is programmed to "Broadcast". Check the device status. If necessary, program the device and put DALI system into operation. Individual DALI devices have no function Cause 1: Load is defective, e.g. lamp. Exchange load. Cause 2: DALI device is defective. Exchange defective device. Switch on voltage. Press c and ALL OFF buttons together for at least 10 seconds. The device detects the exchanges DALI device and loads in the necessary data. The display (4) shows LE. 32587002 10285511 07.08.2013 8/9

i Simultaneous exchange of multiple DALI devices is only possible with commissioning software and project data. None of the DALI groups can be operated. Cause 1: All DALI groups disabled via bus or manual operation. Cancel disabling. Cause 2: Continuous manual mode switched on. Switching off permanent manual control Cause 3: Application software has been stopped, programming LED is flashing. Perform reset: Disconnect device from bus, switch on again after approx. 5 seconds. Cause 4: Application software missing or faulty. Check programming and correct. 6.3 Warranty The warranty is provided in accordance with statutory requirements via the specialist trade. Please submit or send faulty devices postage paid together with an error description to your responsible salesperson (specialist trade/installation company/electrical specialist trade). They will forward the devices to the Gira Service Center. Gira Giersiepen GmbH & Co. KG Elektro-Installations- Systeme Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel +49(0)21 95-602-0 Fax +49(0)21 95-602-191 www.gira.de info@gira.de 32587002 10285511 07.08.2013 9/9