Push button 3gang standard flush-mounted xx
|
|
|
- Norman Hubbard
- 10 years ago
- Views:
Transcription
1 Documentation Product name: Push button 3gang standard Design: device (up) ETS search path: Push button / Push button 3gang / Push button 3gang standard Functional description: The push button 3gang standard is plugged onto a bus coupling unit (BCU) (cf. connection diagram). After a press on the key, the push button sensor will transmit software-dependent telegrams to the KNX / EIB. These may be telegrams for switching, push button operation, dimming or for shutter control. It is also possible to program value transmitter functions such as dimming value transmitter or light-scene extension units. A white operation LED can serve as orientation lighting. Layout Dimensions Controls A B T1 T2 Width: 70 mm Height: 55 mm Depth: 13 mm (without PEI) A: 3 rockers or 6 push buttons (position: left / right) B: 3 x 2 status-led (red) C: 1 x Operation-LED (white) T3 T4 T5 T6 C Data Type of protection IP 20 Safety class III Mark of approval KNX / EIB Ambient temperature: -5 C C Storage / transport temperature -25 C C (storage above +45 C reduces the lifetime) Mounting position any Minimum distances: none Type of fastening plugging onto BCU KNX / EIB supply Voltage V DC (SELV) via BCU Power consumption: typically 150 mw Connection: 2 x 5 pole pin contact strip External supply --- Gebr.Berker 2006 Version: Page: 1 / 9
2 Documentation Response to bus voltage failure Bus voltage only: object values are deleted, LEDs extinguished Response on return of bus voltage: Bus voltage only: no reaction Input: --- Output: --- Connection and terminals: C A B KNX / EIB A: push button standard 3gang B: physical external interface (PEI) C: bus coupling unit (BCU) Hardware remarks --- Gebr.Berker 2006 Version: Page: 2 / 9
3 Documentation Software description ETS search path ETS symbol Push button / Push button 3gang / Push button 3gang standard n PEI type 04 Hex 4 Dez 2 inputs / 2 outputs Applications: No. Summarized description: Name: Version: 1 Switching, status Switching, status Switching, acknowledge Switching, acknowledgement 107A Dimming Dimming 107C Shutter Shutter 107B Value transmitter Value transmitter 107D Gebr.Berker 2006 Version: Page: 3 / 9
4 Documentation Application: 1. Switching, status Number of addresses (max): 13 dynamic table handling: Yes No Number of assignments (max): 13 maximum length of table: 26 Communication objects: 3 0 Switching Push buttons 1 and 2 1 bit C, W, T 1 Switching Push buttons 3 and 4 1 bit C, W, T 2 Switching Push buttons 5 and 6 1 bit C, W, T 0-2 Switching: 1-bit object for the transmission of switching telegrams (, ) Function of operating LED and of status LED parameterizable Command on key press parameterizable (, ) Function of the operating LED Defines the status of the operation LED. Function of the status LEDs Command at operation the left push buttons Command at operation the right push buttons Defines the status of the status LED. Defines the command transmitted on pressing the left push buttons (key 1/3/5). Defines the command transmitted on pressing the right push buttons (key 2/4/6). Software remarks The status LED indicates the current status of the switching object. If a key is pressed (e.g. ) and if the push button sensor does not get a positive acknowledgement (IACK) from an addressed actuator, the object status is updated, but the corresponding status LED is not lit up. Gebr.Berker 2006 Version: Page: 4 / 9
5 Documentation Application: 2. Switching, acknowledge 107A01 Number of addresses (max): 10 dynamic table handling: Yes No Number of assignments (max): 10 maximum length of table: 20 Communication objects: 3 0 Switching Push buttons 1 and 2 1 bit C, W, T 1 Switching Push buttons 3 and 4 1 bit C, W, T 2 Switching Push buttons 5 and 6 1 bit C, W, T 0 2 Switching: 1-bit object for the transmission of switching telegrams (, ) Function of operating LED and of status LED parameterizable Command on key press parameterizable (, ) Function of the operating LED Defines the status of the operation LED. Function of the status LEDs Defines the status of the status LED. Light duration of the status LEDs (push button 1 6) 0.75 s 1.5 s 2.25 s 3.0 s 4.5 s 6.0 s 10 s 15 s Defines the time during which the status LED is on in case of a positive acknowledgement of receipt from an addressed actuator. Command at operation the left push buttons Defines the command transmitted on pressing the left push buttons (key 1/3/5). Command at operation the right push buttons Defines the command transmitted on pressing the right push buttons (key 2/4/6). Software remarks The status LED is on for a parameterizable time in case of a positive acknowledgement from an addressed actuator. If a key is pressed (e.g. ) and if the push button sensor does not get a positive acknowledgement (IACK) from an addressed actuator, the object status is updated, but the corresponding status LED is not lit up. Gebr.Berker 2006 Version: Page: 5 / 9
6 Documentation Application: 3. Dimming 107C01 Number of addresses (max): 12 dynamic table handling: Yes No Number of assignments (max): 12 maximum length of table: 24 Communication objects: 6 0 Switching Push buttons 1 and 2 1 bit C, W, T 1 Switching Push buttons 3 and 4 1 bit C, W, T 2 Switching Push buttons 5 and 6 1 bit C, W, T 4 Dimming Push buttons 1 and 2 4 bit C, T 5 Dimming Push buttons 3 and 4 4 bit C, T 6 Dimming Push buttons 5 and 6 4 bit C, T 0-2 Switching: 1-bit object for the transmission of switching telegrams (, ) 4-6 Dimming: 4-bit object for change of relative brightness between 0 and 100 % Function of operating LED and of status LED parameterizable Function of the operating LED Defines the status of the operating LED. Function of the status LEDs Defines the status of the status LED. Software remarks The status LED indicates the current status of the switching object. If a key is pressed (e.g. ) and if the push button sensor does not get a positive acknowledgement (IACK) from an addressed actuator, the object status is updated and the corresponding status LED is lit up. Gebr.Berker 2006 Version: Page: 6 / 9
7 Documentation Application: 4. Shutter 107B01 Number of addresses (max): 12 dynamic table handling: Yes No Number of assignments (max): 12 maximum length of table: 24 Communication objects: 6 0 Step operation Push buttons 1 and 2 1 bit C, W, T 1 Step operation Push buttons 3 and 4 1 bit C, W, T 2 Step operation Push buttons 5 and 6 1 bit C, W, T 4 Move operation Push buttons 1 and 2 1 bit C, W, T 5 Move operation Push buttons 3 and 4 1 bit C, W, T 6 Move operation Push buttons 5 and 6 1 bit C, W, T 0-2 Step operation: 1-bit object for step (short-time) operation of a shutter 4-6 Move operation: 1-bit object for move (long-time) operation of a shutter Important: Unused communication objects must be projected with dummy group addresses. Otherwise risk of malfunctions. Function of operation LED parameterizable Time between two telegrams (time between STEP and MOVE) presettable Function of the operating LED Defines the status of the operating LED. Push buttons 1 and 2 Time between two telegrams, base Time between two telegrams, factor ( ) 130 ms (fixed) Defines the time base between two telegrams. (time between STEP and MOVE) Time = base factor ; 3 Defines the time factor between two telegrams. (time between STEP and MOVE) Time = base factor Presetting: 130 ms 3 = 390 ms Push buttons 3 and 4 See push buttons 1 and 2 Push buttons 5 and 6 See push buttons 1 and 2 Gebr.Berker 2006 Version: Page: 7 / 9
8 Documentation Application: 5. Value transmitter 107D01 Number of addresses (max): 1 dynamic table handling: Yes No Number of assignments (max): 1 maximum length of table: 2 Communication objects: 1 0 Value / light-scene Rockers 1 byte C, T 0 Value / light-scene 1-byte object for transmitting value telegrams of for recalling lightscenes Function of operating LED and of status LED parameterizable Mode of operation (value transmitter / light-scene recall with / without storage function) freely selectable Values (1 byte) or light-scene numbers (1...8) for all keys individually parameterizable Function of the operating LED Defines the status of the operation LED. Function of the status LED Operating mode Value transmitter Recall light-scene without memory function Recall light-scene with memory function Defines the status of the status LED. Defines the function of the push button sensor. Push buttons 1 and 2 with "Operating mode = value transmitter" ; 1 Defines the value transmitted when the ; 4 Defines the value transmitted when the Push buttons 1 and 2 with "Operating mode = recall light-scene with / without memory function" ; 1 Defines the value transmitted when the ; 4 Defines the value transmitted when the Push buttons 3 and 4 with "Operating mode = value transmitter" ; 1 Defines the value transmitted when the Gebr.Berker 2006 Version: Page: 8 / 9
9 Documentation ; 4 Defines the value transmitted when the Push buttons 3 and 4 with ""Operating mode = recall light-scene with / without memory function" ; 1 Defines the value transmitted when the ; 4 Defines the value transmitted when the Push buttons 5 and 6 with "Operating mode = value transmitter" ; 2 Defines the value transmitted when the ; 5 Defines the value transmitted when the Push buttons 5 and 6 with ""Operating mode = recall light-scene with / without memory function" ; 2 Defines the value transmitted when the ; 5 Defines the value transmitted when the Software remarks Light-scene extension unit: When a key is pressed for more than 1 s, the parameterized light-scene is recalled and the pertaining status LED switched on for about 1 s. If a key is pressed during a light-scene recall with storage function for more than 5 s, a storage telegram corresponding to the parameterized light-scene will be transmitted and the status LED is lit up for 4 s. Pressing a key with storage function for a time between 1 s and 5 s is without effect. The status LED lights up after a key-press only in conjunction with a positive acknowledgement (IACK) from an addressed actuator. Value transmitter: The status LED lights up after a key-press only in conjunction with a positive acknowledgement (IACK) from an addressed actuator. Gebr.Berker 2006 Version: Page: 9 / 9
Light scene push button 8gang comfort flush-mounted 751688xx
751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional
Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx
756627xx, 756637xx, 756657xx Documentation Product name: Push button 2-, 3-, 5- gang RTR + display Design: UP (flush-mounting type) ETS search path: Push button / Push button xgang / Push button xgang
B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x
B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1
Product Manual ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Intelligent Installation Systems This manual describes the function of the EIB monitoring module EUB/S 1.1 with the Application program
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
Tebis KNX Product Documentation. DALI Gateway. Date of issue: 21.11.2006 64540020.111. Order no. 6 4540 020 Page 1 of 131
Tebis KNX Product Documentation DALI Gateway Date of issue: 21.11.2006 64540020.111 Order no. 6 4540 020 Page 1 of 131 Tebis KNX Product Documentation Table of Contents 1 Product definition... 3 1.1 Product
KNX Gateway RGK02-5023E-01
KNX Gateway RGK02-5023E-01 Table of contents Page 1 General Information 1.1 Technical data 5 1.2. Intended Use 6 1.3 Specifications 6 1.4 Compatibility 6 1.5 Scope of delivery 6 2 Information about the
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Inwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX Data Logging Unit BDB/S 1.1 Intelligent Installation Systems ABB This manual describes the function of the Data Logging Unit BDB/S 1.1. Subject to changes and errors excepted.
ABB i-bus EIB Logic Module LM/S 1.1
Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...
ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
Busch-Watchdog Presence EIB Type: 6131-74-102-500
Type: 6131-74-102-500 Contents Technical data 2-2 Application programs (List) 2-3 Circuit diagrams 2-3 in combination with Bus coupler FM (6120-102): Switch Value Cyclic Monitoring /3 2-4 Switch Value
ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1
Product manual ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes
Glass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat
KNX/EIB Product documentation Glass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat Issue: 16.01.2009 65750120 Page 1 of 240 KNX/EIB Product documentation Content 1 Product definition...
ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2
Product Manual ABB i-bus EIB US/U 4.2 US/U 2.2 Intelligent Installation Systems Intelligent and limitless Contents Page 1 General............................................. 3 1.1 Product and functional
ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011
, 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially
Transmitter Actuator 230V wave UP 560. Operation
Transmitter ctuator 230V wave UP 560 5WG3 560-201 Product- and pplication Description Diagram The transmitter actuator 230V wave UP 560 (Diagram ) is a flush-mounted device with radio communication for
Operating instructions. RCD flat 4-fold, 6-fold
Operating instructions 1. Safety instructions Electrical equipment must be installed and fitted by qualified electricians only. Observe the current accident prevention regulations. Failure to observe the
ABB i-bus KNX SA/S Switch Actuators Product Manual
ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional
Tebis application software
Tebis application software Input products / ON / OFF output / RF dimmer Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices WYC81xQ
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX IP Interface IPS/S 2.1 Intelligent Installation Systems ABB This manual describes the function of the IP Interface IPS/S 2.1 with the application program IP Interface. Subject
ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1
Product Manual ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1 Intelligent Installation Systems This manual describes the function of the Switch
Inwall Room Temperature Unit
Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall
Movement/monitoring 1307/1.0 (6325xx)
/monitoring 1307/1.0 (6325xx) General In the following the device will be referred to as the movement detector. The movement block will only switch off when there is no more movement in front of the device
Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S 2.300.2. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX Universal Dim Actuator, MDRC UD/S 2.300.2 Intelligent Installation Systems ABB UD/S 2.300.2 Universal Dim Actuator, MDRC This manual describes the function of the Universal
KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems
KNX Gateway Light-Control R User manual-ver.1 LC-IPGW-001 Intelligent Installation Systems Contents 1. Summary ---------------------------------------------------------------------------------------------------------------------
Unica for KNX system 226
Unica for KNX system 6 P117504 Greater flexibility and comfort, better energy efficiency with KNX More and more electronic appliances are needed for modern comfortable homes that contain everything from
Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes
SI-COLO Series SI-COLO2-LWL-HAMP-COL4 - Big measuring range: typ. 25 mm... 40 mm (with optical fiber and attachment optics KL-14 or KL-17) - Large assortment of optical fibers available (reflected or transmitted
instabus KNX / EIB System System E F G H
Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA
Technical Manual MDT Rain sensor
9/2012 Technical Manual MDT Rain sensor SCN-RS1R1.01 Technical Manual Rain sensor SCN RS1R1.01 1.1. Settings at the ETS Software Selection at the product database: Manufacturer: MDT Technologies Product
Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T
Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T HMG 6 T 4930240 HME 6 T 4930245 HM 12 T 4940245 Updated: Dec-14 (subject to change) Page 1 of 61 Contents 1 Contents 2 FUNCTIONAL
Instruction Manual Service Program ULTRA-PROG-IR
Instruction Manual Service Program ULTRA-PROG-IR Parameterizing Software for Ultrasonic Sensors with Infrared Interface Contents 1 Installation of the Software ULTRA-PROG-IR... 4 1.1 System Requirements...
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
Combi B Alarm box. Mounting instructions
Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power
Application software. Fan coil actuator 2gang RMD. Electrical / Mechanical characteristics : see product information
Application software Fan coil actuator 2gang RMD Electrical / Mechanical characteristics : see product information Order number Product designation Application software ref. TP device RF devices TYF642F
Product and Application Description
Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design
PRODUCT MANUAL LUMENTO X4 LED. LED Controller ZN1DI-RGBX4. Program version: 1.0 Manual edition: a
PRODUCT MANUAL LUMENTO X4 LED LED Controller ZN1DI-RGBX4 Program version: 1.0 Manual edition: a INDEX 1. Introduction...3 1.1. Lumento X4... 3 1.2. Installation... 4 2. Configuration...6 3. ETS Parameterization...7
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011
Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are
ABB i-bus KNX Security Terminals MT/U 2.12.2, MT/S 4.12.2M and 8.12.2M Product Manual
ABB i-bus KNX Security Terminals MT/U 2.12.2, MT/S 4.12.2M and 8.12.2M Product Manual Contents Contents Page 1 General 3 1.1 Use of the product manual...3 1.1.1 Structure of the product manual...3 1.1.2
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
Configuration example: Scene function in the actuator channel in the ETS. 1 Introduction
Introduction Introduction: KNX actuators offer an amazing number of configuration options. Anything from simple feedback function using elapsed-hours meters up to complex scenes can be activated in the
Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable
Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable Designed for use with the COMbricks SALT repeater All baudrates Redundant
SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
ABB i-bus KNX DALI-Gateway DG/S 8.1
Product manual ABB i-bus KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes Dynamic
ABB i-bus KNX i-bus Tool Product Information
ABB i-bus KNX i-bus Tool Product Information A professional Service Tool for System Integrators ABB presents a fully new and innovative software concept with the i-bus Tool. It supports system integrators
Installation Instructions. ThermoCall TC4. Entry/Advanced
Installation Instructions ThermoCall TC4 Entry/Advanced Thermo Call TC4 1 2 # 24990A 965 082 AMP 3 4 # 98393A # 67769A Thermo Call TC4 5 ThermoCall TC4 Entry 1 2 3 4 5 6 7 8 9 10 11 12 sw Please refer
ABB STOTZ-KONTAKT GmbH. ABB i-bus KNX Weather Unit, Weather Sensor
ABB STOTZ-KONTAKT GmbH ABB i-bus KNX Weather Unit, Weather Sensor 2CDC 504 057 N0204 Seite 1 Weather Unit (WZ/S 1.1), Weather Sensor (WES/A 2.1) Overview Weather Unit WZS/1.1 MDRC Application program Sensor
Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004
Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical
Application Unit, MDRC AB/S 1.1, GH Q631 0030 R0111
, GH Q631 0030 R0111 SK 0010 B 98 The application unit is a DIN rail mounted device for insertion in the distribution board. The connection to the EIB is established via a bus connecting terminal at the
SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
Installation Instructions. Thermo Call TC3
Installation Instructions Thermo Call TC3 1 2 # 24990A 965 082 AMP 3 4 # 98393A # 67769A sw Improper installation or repair of Webasto heating and cooling systems can cause fire or the leakage of deadly
MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating
MAKING MORN LIVING POSSIBLE Danfoss heating living connect Installation and User Guide Contents 1.0 System overview... 3 2.0 Overview of display and control buttons... 3 3.0 Installation - step by step...
Shutter Actuator, 8-fold, 230 V AC, MDRC JA/S 8.230.1, GH Q631 0063 R0111. ABB i-bus EIB / KNX
, GH Q631 0063 R0111 2CDC 071 238 F0003 For controlling a maximum of eight independent 230 V AC shutter or sunblind drives via ABB i-bus including the functions Up/Down, Step/Stop, Move to position, Sun
DS1621 Digital Thermometer and Thermostat
Digital Thermometer and Thermostat www.dalsemi.com FEATURES Temperature measurements require no external components Measures temperatures from 55 C to +125 C in 0.5 C increments. Fahrenheit equivalent
Product data base 2.63 (ETS2 1.2 ETS3.0c / vd2-file) Instabus KNX/EIB System
Audio Audio actuator 4fold 0531 00 Audio actuator 4fold Audio actuator mono Audio actuator stereo Communication Infrared 0588.. IR converter IR transmission/reception C00701 Radio 0868 00 Radio-instabus
Z-Wave.Me Wall Controller
Z-Wave.Me Wall Controller ZME_06443: Wall Controller Firmware Version 1.1 1 General Information about Z- Wave Safe: Generally radio systems build a direct link between the transmitter and the receiver.
KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119
EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70
ETS4 Diagnostics. KNX Association
ETS4 Diagnostics Table of Contents 1 Diagnostics and fault location... 3 2 Diagnostics: Individual addresses...... 4 2.1 Devices in Programming Mode... 4 2.2 Checking if an address exists and locating
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions
DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable
Arcus-EDS Product Description LCD-Color-Display
Arcus-EDS Product Description 010 ,, Article Nr: 200111xx (x: 0=without panel; 3=with V2A-panel) (x: 1=white; 2=anthracite) The LCD Display communicates with different devices of the modern electric installation
Belimo Gateway MP to Modbus RTU - UK24MOD
Product information UK24MOD MODBUS RTU Belimo Gateway MP to Modbus RTU - UK24MOD Contents Complete overview 2 Technical data 3 Safety notes 4 Product features 4 Installation and commissioning 4 Electrical
FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
ABB i-bus EIB / KNX Room Controller
Product Information ABB i-bus EIB / KNX Room Controller Intelligent Installation Systems The Concept One Room Controller per Room The Room Controller consists of a basis device, into which up to 8 selected
Wind Sensor W-RS485 with RS485 Interface
Wind Sensor W-RS485 with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Steuerungs- und Automatisierungstechnik Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70 56/93
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
Application software. 3-channel LED KNX controller Electrical / Mechanical characteristics : see product information. Application software ref.
Application software 3-channel LED KNX controller Electrical / Mechanical characteristics : see product information Order number Product designation Application software ref. TP device RF devices TYB673A
DS1621 Digital Thermometer and Thermostat
www.maxim-ic.com FEATURES Temperature measurements require no external components Measures temperatures from -55 C to +125 C in 0.5 C increments. Fahrenheit equivalent is -67 F to 257 F in 0.9 F increments
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI
Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI OSRAM GmbH Hellabrunner Str. 1 D-81536 Munich Tel.: +49 (0) 89 6213 0 Fax: +49 (0) 89 6213 2020 Customer Service Center (KSC)
KNX/EIB Product documentation. Master Control. Issue: 23.10.2008 1353702x. Order-No. 7574 00 1X Page 1 of 222
KNX/EIB Product documentation Master Control Issue: 23.10.2008 1353702x Page 1 of 222 KNX/EIB Product documentation Content 1 Product definition... 4 1.1 Product catalogue... 4 1.2 Function... 4 1.3 Accessories...
PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP10425844)
In the Master function, the remote control entries will be acknowledged as follows: acknowledged 3 x with the red LED In the Slave function, each detection is acknowledged 2 x with the green LED. 6 TEST
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
Multi-Protocol decoder 76 200 with Load regulation
Multi-Protocol decoder 76 2 with Load regulation For locomotives with universal motors on digital layouts operating in the DCC and Motorola data format. Features 76 2 Load regulated multi-protocol decoder
DeviceNet Bus Software Help for Programming an Allen Bradley Control System
FBP FieldBusPlug V7 DeviceNet Bus Software Help for Programming an Allen Bradley Control System DeviceNet Software Help for Programming an Allen Bradley Control System Contents Page General Purpose...
2013 Wireless Video Intercom INSTALLATION GUIDE
2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door
Multi-Protocol decoder 76 400
Multi-Protocol decoder 76 For locomotives with DC motors on digital layouts operating in the DCC- and Motorola data format. Features Regulated multi-protocol decoder for DCC and Motorola Suitable for DC
wdali Remote Datasheet DALI RF Remote Control Wireless DALI control unit with 12 programmable momentary switches
wdali Remote Datasheet DALI RF Remote Control Wireless DALI control unit with 12 programmable momentary switches Art. Nr. 86459534-W (white) Art. Nr. 86459534-B (black) wdali Remote wdali Remote DALI RF
Functions module / Gateways. KNX-GW-RS232-RS485 Product Group 1
Seite 1 KNX--RS232-RS485 Product Group 1 Document: 4300_ex_KNX--RS232-RS485.pdf KNX- -RS232 -RS485 The KNX--RS232-RS485 is a gateway between the KNX-Bus and the serial lines RS232 and RS485. It can be
KNX L. Brightness Sensor. Installation and Adjustment. Item number 70119
EN KNX L Brightness Sensor Item number 70119 Installation and Adjustment 1 Content 1. Description... 3 1.1. Technical specifications... 3 2. Installation and commissioning... 4 2.1. Installation notes...
Mounting and Operating Instructions. TV gateway 2610..
Mounting and Operating Instructions TV gateway 2610.. Table of contents Device description... 3 Connection to a television... 4 Connection to a BK system (cable connection)... 5 Connection to the world
IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.
IntesisBox KNX SAMSUNG Air Conditioning Gateway for integration of Samsung air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX EIB Bus IntesisBox RS485 MIM-B13x/B04A
Thru-Beam 80 to 320 mm 0.05 to 0.08 mm
Series 7069A Fiber Optics The 7069A coupled with the appropriate cable forms a fiber optic sensor controller system capable of detecting objects as small as 0.01mm dia. and color marks on backgrounds of
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 [email protected]
Integrations LGAC-KNX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 [email protected] www.ingeniumsl.com
Mureva Assembly surface mounted wiring devices
1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label
Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light
Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light In this issue, we would like to present the EnOcean radio sensor module STM 110 in more detail. The module
3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
Technical description MX-1 VB Edge
1 (7) Technical description MX-1 VB Edge 2 (7) Table of Contents 1 General description...3 2 Connectors...4 3 ON/OFF operation...5 4 Power...5 5 LED indicators...6 6 Enclosure...6 7 Mounting...6 8 and
I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP
I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP 1. Functions An I. S. 1 fieldstation can be equipped with a primary and a redundant central unit (), whereby each has its own independent PROFIBUS
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24