contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control
|
|
|
- Gwen Walters
- 9 years ago
- Views:
Transcription
1 Wireless Control Systems
2 Accessories Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Accessories Programming Switching & Dimmer Functions Installation Guidelines a4 a6 a10 a14 a16 a21 a23 a24 a25 Why Click INELS Wireless? Complete control and regulation of your heating and lighting means energy is only consumed when needed - reducing your energy bills and your carbon footprint. No additional cables or wall cutting needed. can be installed behind light fittings or into suitable installation boxes Flexible positioning makes Control ideal for installation within existing or newly constructed buildings. With Control, you can move switches freely and re-locate when required. Switches can be mounted on glass, wood or walls etc. Transmitters are powered by battery and so do not require any wiring or additional power supply. Universal input transmitter converts up to 4 pushbutton switches - enabling existing devices to be connected to the system. Operates on 868MHz frequency band which provides robust communications. Complete control Allows portable and remote control up to a distance of 200m Control and adjustment of lights, on/off or create lighting scenes. Control shutters, blinds, gates, latches and garage doors Manual or automatic control Monitor window or door opening Simulate occupancy when you are away from home a2 call: fax: [email protected] visit: call: fax: [email protected] visit: a3
3 Range Overview Range Overview Transmitters WB-20/G WB-40/G KEY DEL-71B SAI-61B SA-61B SC-61 2 Channel Switch Controller 4 Channel Switch Controller 4 Channel Remote Switch Controller Key Fob Multifunctional Dimming Actuator c/w Switch Input 1 Channel Multifunctional Switching Actuator c/w Switch Input 1 Channel Multifunctional Switching Actuator with Antenna 13A Switching Socket Pilot TP-83 TC-10G JA-12B/24V DC DAC-71B SA-62B JA-12B/230V 4 Channel Universal Switch Adapter 40 Channel Remote Control Wireless Room Thermostat Temperature Regulator Shutter Actuator (24V DC) Dimming Actuator 1-10V Analogue Output 2 Channel Switch Actuator Shutter Actuator 230V AC TOUCH TI-10B JA-83P RP-20/B Advanced Control of Multiple Devices Wireless Thermo-Sensor Wireless Window/ Door Contact Compact PIR Sensor (Indoor use only) 6 Channel Multifunctional Switch Receiver 2000W Remote dimmer unit Signal Repeater (with un-switched 13A power outlet) a4 call: fax: [email protected] visit: call: fax: [email protected] visit: a5
4 Typical Installations Typical Installations Each installation will require at least: For a simple switching circuit all you need is a transmitter (switch or remote) and a receiver (also referred to as an actuator). More complex installations will utilise multiple units and multiple types of unit. The following illustrations detail a few examples of installations of varying complexity. Guideline installation: This setup utilises the Pilot to give the user full control of up to 40 actuators. The setup demonstrates the use of dimming actuators, 2-channel switching actuators and shutter actuators. The setup also indicates the use of the Universal switch adapter used in conjunction with Click Deco Mini-grid modules in order to match decorate switches throughout the installation. With the Pilot, the user can set scenes that control groups of receivers. You will need: WB-20/G (2 Channel Switch) SA-61B (Switching Actuator) JA-12B (Shutter Actuator) (Universal ) Switch Adapter Pilot (Remote Control) SA-62B ( 2 Channel) Switch Actuator DA-71B (1 Dimming) Actuator Connect the receiver to the lighting circuit, usually connected inside an adaptable box and placed into the ceiling void. The unit will require a permanent live and neutral feed. Fix the switch to standard single gang back-box or use the sticky pads provided to fix the switch to any surface. Up to 32 transmitters (switches) can be paired with a single receiver (actuator), making it simple to create complex switching circuits. a6 call: fax: [email protected] visit: call: fax: [email protected] visit: a7
5 Typical Installations Typical Installations TOUCH All controlled from a single point. Simulated Occupancy The Touch allows you to set daily and weekly programs for multiple groups of actuators allowing you to create complex routines that will run whether you are at home or away. These routines can also be used effectively to save energy around the home, by ensuring your devices are switched off when they are not required. Garage Doors Use Shutter actuators and a key fob to control garage doors or gates remotely. Can also be used with Touch, Pilot and other wall-mounted switches. Door / Window Status Feedback Monitor the status of windows and doors on your property. Combine this function with a switching or dimming actuator to create a circuit that activates or deactivates when the door or window is open or closed. Scene Setting The Touch, as well as the Pilot, can group multiple actuators together and allow you to quickly set them to a predetermined level or status. For example: The User creates Movie Mode which dims multiple zones of lights via a dimming actuator and switches off another zone via a switching actuator. Also useful for setting master off functions. Lighting Control Create remote control outdoor lighting circuits to enable the user to switch the lights on or off when approaching or leaving the property. Heating Control The Touch presents an interface that can allow the user to connect a temperature sensor to a switching actuator that can in turn be connected to a number of heating appliances. This action combined with a weekly/daily program can allow the user to control the heating appliance based on both temperature and time. Temperature Monitoring The Touch can be connected to a number of thermostat devices and display their results on screen. This allows the user to get temperature feedback on any room or even outdoors. a8 call: fax: [email protected] visit: call: fax: [email protected] visit: a9
6 Transmitters Wireless Switch Key Fob Universal Input Transmitter WB-20/G WB-40/G Transmitters KEY-W Remote Controller KEY-B Transmitters WB-20/G WB-40/G KEY-W KEY-B IM-40B Wall 2-Channel Controller Wall 4-Channel Controller 4-Channel Remote Key Fob - White 4-Channel Remote Key Fob - Black Universal Input Transmitter (Use With Standard Centre Off Retractive Switches) Cable Length: 90mm Standards: EN 60669, EN , EN Dimensions: WB-20/G, WB-40/G: 85mm x 85mm x 16mm KEY: 64mm x 25mm x 10mm 49mm x 49mm x 13mm Battery Type: CR 2032 a10 call: fax: [email protected] visit: a11
7 Transmitters Temperature Regulator Thermo-Sensor & Thermostat PIR Sensor Transmitters Window Door Contact Remote Controller Window Door Contact TC-10G * TI-10B AN-E TP-83 JA-83P PILOT * For use with Touch unit only Transmitters TC-10G TI-10B TP-83 SG-1M AN-E Transmitter: Zone / Room Temperature Regulation / Measuring Device * Transmitter: Wireless Thermo-Sensor Hand held Room Thermostat / 24 Hour 7 Day Time Programmer 230V Single Channel Switch Transmitter (Din Rail Mount) Transmits a continuous signal with input status ON or OFF. Programs to function 1 of switching actuators. External Antenna (3m fitted cable) For use with SA-61M, SA-66M & SG-1M For thermo-sensor accessories see page a22 Transmitters JA-82M JA-83M PILOT JA-83P Hand held Window / Door Contact Magnetic Door/Window Surface Contact Hand held 40 Channel Remote Controller Compact PIR Sensor (Indoor use only) Standards: EN 60669, EN , EN TP-83: EN , EN 55022, EN Dimensions: TC-10G: 85mm x 85mm x 20mm TI10B: 49mm x 49mm x 13mm TP-83: 66mm x 90mm x 22mm 90mm x 17.5mm x 64mm Battery Type: TC-10G: AAA (x2), TI-10B: CR 2477 (x1), TP-83: AA (x1) Standards: EN , EN 55022, EN 60950, EN 60669, EN , EN Dimensions: 25mm x 192mm x 9mm,31mm x 75mm x 23mm, 16mm x 56mm x 15mm JA-83P: 60mm x 85mm x 55mm, PILOT: 41mm x 130mm x 18mm Battery Type: CR 2354 (x2), CR 123A (x1), PILOT: AAA (x2) a12 call: fax: [email protected] visit: call: fax: [email protected] visit: a13
8 Combined Modules Wireless Central Unit Wireless Switching Actuator Combined Modules STI-11B * For use with Touch unit only Combined Modules T-WBK Wireless Touch Screen Controller - Black ( Touch) T-WWH Wireless Touch Screen Controller - White ( Touch) STI-11B * 16A Wireless Switching Actuator With Thermo-Sensor For thermo-sensor accessories see page a22. Touch supplied with DC Adaptor. Can be hard wired into the rear of the unit via 230V supply. Standards: EN 60730, STI-11B: EN 60669, EN , EN Dimensions: 94mm x 94mm x 24mm STI-11B: 49mm x 49mm x 21mm a14 call: fax: [email protected] visit: call: fax: [email protected] visit: a15
9 Switching Actuator SA-61B SA-62B SAI-61B AN-E SC-61 SA-61B SA-62B SAI-61B SA-61M SA-66M SC-61 AN-E 16A 1 Channel Multifunction Switching Actuator 8A 2 Channel Multifunction Switching Actuator 16A Switching Actuator C/W Control Input Can utilise retractive switch in conjunction with the 3V DC switch input. 16A 1 Channel Multifunction Switching Actuator 8A 6 Channel Multifunction Switching Actuator 13A 240V Switching Socket External Antenna (3m fitted cable) For use with SA-61M, SA-66M & SG-1M Standards: EN 60669, EN , EN , SC-61: BS1363 Dimensions: SA-61B, SA-62B, SAI-61B: 49mm x 49mm x 21mm, SC-61: 60mm x 12mm x 80mm 90mm x 17.5mm x 64mm, 90mm x 52mm x 65mm Cable Length: SA-61B, SA-62B, SAI-61B: 90mm Relay Current Ratings: AC1 a16 call: fax: [email protected] visit: call: fax: [email protected] visit: a17
10 Dimming Actuator Shutter Actuator DA-71B DEL-71B JA-12B/230V JA-12B/24V DAC-71B DA-71B DEL-71B DAC-71B DIM VA 1 Channel Multifunction Dimming Actuator 160Va 1 Channel Multifunction Dimming Actuator C/W Control Input Compatible with most dimmable LED light sources. Will dim up to 160W of LED. Can utilise retractive switch in conjunction with the 230V~ switch input. 16A 1 Channel Multifunction Dimming Actuator Complete With 0-10V Or 1-10V Analogue Output 2000W Remote Dimmer Unit Must be used in conjunction with DAC-71B or other 0(1)-10V analogue input JA-12B/24V Shutter Actuator (DC) 12-24V JA-12B/230V Shutter Actuator (AC) 230V Standards: EN 60669, EN , EN Dimensions: DA-71B, DEL-71B, DAC: 49mm x 49mm x 21mm, 105mm x 90mm x 65mm Cable Length: DA-71B, DEL-71B, DAC-71B: 90mm Standards: EN 60669, EN , EN Dimensions: JA-12B/230V: 49mm x 49mm x 21mm, JA-12B/24V: 49mm x 49mm x 13mm Cable Length: 90mm a18 call: fax: [email protected] visit: call: fax: [email protected] visit: a19
11 Repeater Signal Repeater RP-20/B Accessories Thermo-sensor RP-20/B 240V Signal Repeater (with un-switched 13A power outlet) Extends the range by up to 200 metres for up to 20 receivers Standards: EN / BS1363 Dimensions: a20 call: fax: [email protected] visit: call: fax: [email protected] visit: a21
12 Accessories Thermo-sensor Programming Follow these very simple, easy to follow instructions when programming functions: STEP 1 - ACTIVATE STEP 2 - SELECT FUNCTION Press & hold the programming button on the receiver for 2 PROGRAMMING BUTTON STATUS LED WILL FLASH PER SECOND To assign the chosen transmitter device button & function, press the required button the number of times to match the function number required at one second intervals - SEE TABLE 1 on opposite page (e.g for transmitter function 2, press the button 2 times). FUNCTION BUTTON PRESS AND HOLD FOR 2 SECONDS PRESS THE NUMBER OF TIMES THAT CORRESPONDS TO THE DESIRED FUNCTION TC TZ STEP 3 - ONLY REQUIRED FOR FUNCTION 5 & 6 FOR ALL OTHER FUNCTIONS GO TO STEP 4 To set the time element, press & hold the programming button second interval). THE TIMER HAS NOW STARTED. When the required time period has elapsed, press the previously assigned STEP 4 - SAVE AND EXIT To exit programming mode press the programming button for 1 second only. PRESS AND HOLD >5 SECONDS STATUS LED WILL FLASH TWICE PER SECOND PRESS AND HOLD FOR 1 SECOND TO DELETE A SINGLE FUNCTION TO DELETE ALL STORED FUNCTIONS Accessories (Heat Resistant PVC) TC-3 Temperature Sensor 3 m (9.8 ) TC-6 Temperature Sensor 6 m (19.7 ) TC-12 Temperature Sensor 12 m (39.4 ) 0 c > 70 c Accessories (Silicone) TZ-3 Temperature Sensor 3 m (9.8 ) TZ-6 Temperature Sensor 6 m (19.7 ) TZ-12 Temperature Sensor 12 m (39.4 ) -40 c > 125 c STAGE 1 PRESS AND HOLD FOR 5 SECONDS STAGE 2 FUNCTION BUTTON PRESS THE BUTTON THAT CORRESPONDS THE DESIRED FUNCTION TO DELETE STATUS LED WILL FLASH TWICE PER SECOND PRESS AND HOLD 8 SECONDS - THIS WILL DELETE ALL STORED FUNCTIONS. RELEASE PROGRAMMING BUTTON AND THEN PRESS FOR 1 SECOND TO EXIT a22 call: fax: [email protected] visit: call: fax: [email protected] visit: a23
13 Functions Installation Guidelines Function 1 Press button Press for ON, release for OFF Function 2 On button Press for ON Function 3 Off button Press for OFF Function 4 On/Off button Press for ON, press again for OFF Function 5 Off delay Press for ON, device will turn off after pre-determined time period as set in step 3 of programming (2 secs - 30 mins max) Function 6 On delay Press to start timer. On delay will be as pre-determined in step 3 of programming (2 secs -30mins) To ensure correct and safe operation of a device please follow the installation guidelines below: Do not install into an exterior or wet environment over temperature protection which will switch the device output off when the system is overloaded Do not install components into metal and steel distribution boards as this will reduce the radio-frequency signal The range of radio signal within the Control system depends on building construction and physical location of the devices - see table 1 below Do not connect inductive and capacitive loads to one device at the same time - see table 2 on previous page. Function 1 Scene recall / OFF Press to recall scene, press to turn OFF Press button for more than 1 second to set scene brightness Function 2 Scene recall / OFF - anti-tamper Press to recall scene, press again to turn OFF Press button for more than 3 seconds to set scene brightness (avoids accidental scene setting) Function 3 Function 4 Function 5 Scene recall - fade ON / fade OFF - push to recall scene Scene recall / fade OFF Variable fade up to Max. Press to recall scene Press to recall scene Press to start fade up time to maximum brightness Function 6 Variable fade down to OFF. Press to start fade down to OFF Function 7 ON/OFF Press once for ON, press again for OFF Press button for more than 1 second to set scene brightness Press button for more than 1 second to set scene brightness N/A N/A N/A IM SA - 6IB L TRANSMISSION OF RADIO-FREQUENCY SIGNALS THROUGH VARIOUS MATERIALS R - RESISTIVE L - INDUCTIVE C - CAPACITIVE 60-90% 80-95% 20-60% 0-10% 80-90% brick walls wooden constructions with plaster boards reinforced concrete metal bars regular glass a24 call: fax: [email protected] visit: call: fax: [email protected] visit: a25
14 Notes a26 call: fax: visit:
Wireless electroinstalation. www.inels.cz. Product ranges
Product ranges 1 History: 2008: Launch of the RF Control system 2009: RF Control & Oasis compatible 2010: RF Touch introduced 2011: RF Pilot available 2012: elan-rf-003 started to be sell 2013: inels Home
TYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel
Installation and User Guide TYXIA Wireless receiver TYXIA RF 642-1 channel DELTA DORE Bonnemain - 35270 COMBOURG - France E-mail : [email protected] Unit compliant with the requirements of directives:
Basics of Dimming. ISC Learning Centre
ISC Learning Centre July 2009 > Dimmers Contents What is a dimmer? Dimmers & customer benefits Dimmers at home Dimmers at the office Dimmers: technical choices Overview of the Schneider Electric offer
Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI
Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI OSRAM GmbH Hellabrunner Str. 1 D-81536 Munich Tel.: +49 (0) 89 6213 0 Fax: +49 (0) 89 6213 2020 Customer Service Center (KSC)
Model: 616-146v2 Quick Setup Guide DC: 071015 Atomic Projection Alarm with Indoor and Outdoor Temperature
Model: 616-146v2 Quick Setup Guide DC: 071015 Atomic Projection Alarm with Indoor and Outdoor Temperature Snooze/Backlight BUTTONS Time, Alarm with Snooze, & Calendar Projection Arm Rotates 180 Indoor/Outdoor
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
Inwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System
ELITE-L Series ELITE - Low Voltage / Dry contact Remote Control System Applications Garden Lighting Pond pumps Remote outdoor Switching Access control Industrial control Features 4 switched channels 1000W
CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access
CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance
ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2
Product Manual ABB i-bus EIB US/U 4.2 US/U 2.2 Intelligent Installation Systems Intelligent and limitless Contents Page 1 General............................................. 3 1.1 Product and functional
Transmitter Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso
Transmitter Speed 1 9 3 5 0 Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso E L S Tr a n s m i t t e r S p e e d M a n u a l 0 2. 0 2. 2 0 1 0 / / 7
Wireless Home Security Alarm System AM 500
Wireless Home Security Alarm System AM 500 12 MONTH GUARANTEE Installation & Operating Instructions INTRODUCTION The AM500 is a simple self-contained alarm system. It protects the home by sounding a siren
KNX Gateway RGK02-5023E-01
KNX Gateway RGK02-5023E-01 Table of contents Page 1 General Information 1.1 Technical data 5 1.2. Intended Use 6 1.3 Specifications 6 1.4 Compatibility 6 1.5 Scope of delivery 6 2 Information about the
NX-10-V3 wireless system. To wire or not to wire?
NX-10-V3 wireless system To wire or not to wire? Now your security goes where you go Our NX-10-V3 system is fully wireless with a keypad in a designer housing. The hybrid series goes where no security
Intelligent energy saving. Wireless control. Wired for sound
Home automation Where we once fantasised about appliances and home fittings making our lives easier, home automation is quickly becoming a reality. Worth around 65 million in 2011, it is estimated that
MAGICAR M871A. Car alarm with two-way remote User s guide
MAGICAR M871A Car alarm with two-way remote User s guide EN MAGICAR M871A Car alarm with two-way remote User s guide TABLE OF CONTENTS Table of contents...2 1. Important notice...4 2. Introduction...4
Power Socket (2 Gang)
Version 2.1 Power Socket (2 Gang) Model No. LW270 Instruction Manual Connect Series www.lightwaverf.house EC DECLARATION OF CONFORMITY Responsible Authority: LightwaveRF PLC, Innovation Campus Birmingham
GSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
IN-OUT Thermometer with Cable Free Sensor and Clock
IN-OUT Thermometer with Cable Free Sensor and Clock MODEL: RAR232 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RAR232 In-Out Thermometer with 433MHz cable free sensor and calendar
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
Residential & Commercial Alarm Systems by Gross Security, LLC
151 Main Street, Suite, 1, Get these great features with a landline or cellular alarm system from Gross Security, LLC Alarm system prices include installation Base system includes one hour of training
RF 1. Contents: Connecting diagram. Detailed information:
Contents: Introduction UFH-ZONE-R UFH-EXTRAZONE -R Connection of a thermostat (UFH-THERM-R) o Joining of a thermostat with UFH-ZONE-R or UFH-EXTRAZONE-R Connection of a digital thermostat (UFH-THERM -RD)
Safety Warnings and Guidelines
Safety Warnings and Guidelines Thank you for purchasing this Wireless Speaker Amplifier! For best results, please thoroughly read this manual and carefully follow the instructions. Please pay extra attention
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Operating instructions for built-in electronic timers with Day and Week programms. Series 884
Operating instructions for built-in electronic timers with Day and Week programms Series 884 Attention: This operating manual is destined for our OEM customers and is intended as a basis for the instruction
WIRELESS HOME ALARM SYSTEM (WHA1)
WIRELESS HOME ALARM SYSTEM (WHA1) IMPORTANT : PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS ALARM SYSTEM. SAFETY Please note: Before you start to install this alarm, we
DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions
DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable
PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.
WIRELESS AUTODIAL HOME ALARM SYSTEM AM2000 Instructions for use Important! Please read these instructions carefully. IMPORTANT 1 IDENTIFICATION PLEASE CONTACT BEFORE RETURNING THIS PRODUCT TO THE RETAILER
3466 Building Energy Management Training Systems
3466 Building Energy Management Training Systems LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2015 Table of Contents General Description 3 Courseware 3 Topic Coverage 4 List of Available
Stove Guard Kit User Manual
Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent
Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION
Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION FRONT VIEW SENSOR TX141TH-Bv2 LED TX Sensor Battery Cover Sensor Battery Compartment 2 AA Buttons Battery Compartment 3 AAA BACK VIEW Battery
1. Overview. WPT Wireless Range Tester Kit User Manual Doc No. 910-00009-01 Rev 05. 1.1. Components. 1.2. Prerequisites for Site Survey
1. Overview The Cypress Envirosystems Wireless Pneumatic Thermostat (WPT) retrofits an existing pneumatic thermostat to provide Direct Digital Control (DDC) like zone control functionality at a fraction
WIRELESS WEATHER STATION Model 81690 USER'S INSTRUCTIONS
WIRELESS WEATHER STATION Model 81690 USER'S INSTRUCTIONS The multifunctional weather station is equipped with many functions providing thorough weather information to you. The receiver unit has a clear,
Secure Keypads for access control
torm Secure Keypads for access control Strike Master Read this manual carefully before attempting to install, program or operate the STORM AXS Strike Master Keypad. After installation the Command Summary
Transmitter Actuator 230V wave UP 560. Operation
Transmitter ctuator 230V wave UP 560 5WG3 560-201 Product- and pplication Description Diagram The transmitter actuator 230V wave UP 560 (Diagram ) is a flush-mounted device with radio communication for
Intruder Alarm System
Intruder Alarm System GSM & PSTN Wireless and Wired Touch Model 2013-01 V1.0.0 Statment This equipment must be installed and used in strict accordance with the instructions given in this user documentation.
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
Atomic Projection Alarm with Indoor and Outdoor Temperature
Model: WS-5220U-IT Instruction Manual DC: 082415 Atomic Projection Alarm with Indoor and Outdoor Temperature SNOOZE button Time, Alarm + WWVB Icon Projection arm Indoor Temp., Outdoor Temp. Battery Compartment
15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
Passion for KNX innovation
Passion for KNX innovation Touch-MyDesign 2 Touch-MyDesign is a KNX switch with capacitive buttons that satisfies the design requirements of any building thanks to its total customization: Everyone can
Quick start: Energy Switch EU
Technical specifications Normal operating voltage Quick start: Energy Switch EU 230Vac/50Hz Recommended max. load 3000W 600W Frequency range Wireless range Energy measurement 868.42 MHz 30~100 meters in
AARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS
Wireless - Emergency Alert Systems Easy installation - Wireless Radio System no wires or wiring required Evacuation, Alert & Lockdown all in one system S.O.S Assist - up to 6 unique SOS assistance zone
PiSector Home security systems
PiSector Home security systems User Manual (ALM-S02) Read manual fully before use. PiSector Inc., USA, www.pisector.com Thank you for purchase this alarm system, For proper use and your safety, please
RADIO CONTROLLED DIGITAL CLOCK MODELS 88905 / 88906
RADIO CONTROLLED DIGITAL CLOCK MODELS 88905 / 88906 QUICK SETUP GUIDE IMPORTANT! INSTALL BATTERIES IN THE OUTDOOR TRANSMITTER BEFORE INSTALLING BATTERIES IN THE RADIO-CONTROLLED CLOCK. ALKALINE BATTERIES
ZME_WALLC-S Z-Wave Secure Wall Controller
ZME_WALLC-S Z-Wave Secure Wall Controller Firmware Version : 1.0 Quick Start S This device operates as Z-Wave sensor in two modes: the normal control mode (daily use) or in management mode for setup. Pushing
Reference. 910 402 230 V, 50 Hz A10 415 120 V,60 Hz. 916 402 230 V, 50/60 Hz A16 418 120 V, 50/60 Hz. 910 103 230 V, 50 Hz A10 104 120 V, 60 Hz
Rex - analog time switches MicroRex - 3 modules for DIN rail mounting Rex - analog time switches MicroRex - module for DIN rail mounting 926 428 A0 4 MicroRex T3 24 hour program, synchronous motor 92 429
MOBILE CALL GSM Alarm System User s Manual
MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction Alarm Host Diagram
Six-defense zone Display Alarm System. User Manual
Six-defense zone Display Alarm System User Manual Feature 1. Anti-interfere function. When someone interferes it with same frequency, the control unit will activate siren to alarm. 2. Support anti-decode
B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x
B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with
EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch
Going green EKON BMS HVAC system Wireless Thermostat with Light Switch Control Fan Coil or Central AirCon Wireless Touch Screen Controller Wireless Light or Motorized Blind Wall Switch www.ekonhome.com
Monitoring and security of vehicles
Monitoring and security of vehicles Monitoring Security Control 2 / MONITORING / Products Vehicle fleet monitoring Efficient tracking of your corporate vehicles with very easy installation. Thanks to the
Installer Guide smart connect
Installer Guide smart connect TM 7330 Wireless Remote Humidity Sensor Please read all instructions before proceeding. The wireless remote humidity sensor monitors the humidity passing through the return
TX GSM SMS Auto-dial Alarm System. Installation and User Manual
TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses
HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function
Specifications Supply Voltage 240VAC @ 0.07Amps or 24VAC @ 0.380Amps Relays 240V @ 12A max (resistive) / Comp1,2,3, Aux Ht, Rv O/B) Fuses (Equipment) 15 Amps Maximum 3AG Control Range Minus 10 to 50C Control
e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL
Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL e-4 SAFETY PRECAUTIONS Federal
ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION
ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION 2014 Ferport/Armas has over 30 years been synonymous with technology, reliability and experience in
ReSound Unite TV FREQUENTLY ASKED QUESTIONS. Setup & Configuration. Use & Operation. Troubleshooting
Tip for use of FAQ: Click on questions to go to answer. Setup & Configuration How do I pair the hearing aids to the Unite TV?... 2 What is the latency of the streamed signal?... 2 Does the Unite TV use
Total Protection Alarm System
www.skylinkhome.com Total Protection Alarm System MODEL: SC-10 101A073-001 AUG, 2005. CUSTOMER SERVICE 17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 Tel : (800) 304-1187 Fax : (800) 286-1320 Email
Mini Timer Owner's Manual. Model MT13A
Mini Timer Owner's Manual Model MT13A Contents Introduction...3 Quick Tour...5 How to program a timed event...6 Special programming buttons...6 Setting up the Mini Timer...7 Setting the clock...7 Controlling
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
Lighting Management solutions
Lighting Management solutions Best practice guide for office buildings PUTTING A STOP TO ENERGY WASTE INTRODUCTION Table of contents 1 Lighting control Best Practice Guide for Office Buildings 2 Guide
Business/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
HORNET Remote Control Systems
HORNET Remote Control Systems Up to 100metres Range 1 3 Button versions 12-30Vdc 0r 230Vac versions Reliable FM Technology Up to four 1000W Relay switches Waterproof Receiver (IP68) Momentary or Latching
Tebis application software
Tebis application software Input products / ON / OFF output / RF dimmer Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices WYC81xQ
SMART COMFORT & EASY EFFICIENCY HEATING CONTROLS
SMART COMFORT & EASY EFFICIENCY HEATING CONTROLS About Delta Dore Since 1970, Delta Dore manufactures heating controls for both water based heating and electric heating. Room thermostats, programmable
PSTN Home Alarm System
PSTN Home Alarm System User Manual Model: PST-TEL99E Please read this user guide carefully before operation and installation. Contents 1. Product Overview... - 3-2. Main Function & Features... - 3-3. For
Product data base 2.63 (ETS2 1.2 ETS3.0c / vd2-file) Instabus KNX/EIB System
Audio Audio actuator 4fold 0531 00 Audio actuator 4fold Audio actuator mono Audio actuator stereo Communication Infrared 0588.. IR converter IR transmission/reception C00701 Radio 0868 00 Radio-instabus
Home Security Alarm System
Home Security Alarm System User Manual (ALM-S02) Read manual carefully before use. PiSector Inc., USA www.pisector.com Thank you for purchasing this home security alarm system. For your safety and better
Stylish Electrical Essentials
Stylish Electrical Essentials Switches Sockets Fused Connection Units Control Switches 45A Switch Plates Flex Outlet & Blank Plates Telephone and Data Outlets Coaxial and Satellite Outlets Cavity Wall
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
REMOTE TERMOMETER TE 219 LED USER MANUAL
INTRODUCTION REMOTE TERMOMETER TE 219 LED USER MANUAL Thank you for purchasing this unit with indoor thermometer, wireless thermometer sensor and radiocontrolled clock. This device is also equipped with
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
WPR400 Wireless Portable Reader
P516-098 WPR400 Wireless Portable Reader User guide Para el idioma español, navegue hacia www.schlage.com/support. Pour la portion française, veuillez consulter le site www.schlage.com/support. Contents
SERIES ͲΝΒΣΞ ΒΟΘΖ Swann 2013
SERIES Swann 2013 Home Protection that s Advanced & Easy Doorways Windows Garages Sheds Potential Entry Points Blind Spots ALARM SENSOR A typical home layout with suggested mounting points for alarms www.swann.com
Fibaro electronic modules are smallest devices of the type in the World and can be installed in all standard wall switch boxes,
Fibaro Z-Wave modules: Compatible with any Z-Wave home automation system, Fibaro electronic modules are smallest devices of the type in the World and can be installed in all standard wall switch boxes,
Quick Installation Guide LCD GSM ALARM SYSTEM LH http://www.usmartbuy.com
A. Manipulation Specification Quick Installation Guide 1. Arming Arming means all-around guarded when there is no person at home. All detectors are working. Once something triggers any of the detectors,
Digital Radio/DAB+/FM RDS digital clock radio with dual alarm Operating instruction
381SE1D-A Digital Radio/DAB+/FM RDS digital clock radio with dual alarm Operating instruction GB Contents Controls... 2-3 Using the clock radio for the first time... 4 Operating your clock radio... 5 Selecting
Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location
Wireless Alarm System Panic Button User s Manual Choice ALERT Control all sensors, accessories and remote transmitters from one location Table of Contents Important Safeguards 4 Introduction 5 Activating
Wireless Alarm system s manual
MOUNTVIEW TECH AUSTRALIA PTY LTD Wireless Alarm system s manual ADS A180 Series ADS Security 1/11/2011 1. Before You Begin For your safety and the safety of others, and to ensure that you get the most
GSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.
New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.
New GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Alarm Host Introduction Chapter
WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER
BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.
AD425S Automatic door operator
EC8666 Statement Automatic Door Operator is a reliable and quiet door opening and closing device. This product is ideal for enabling access to areas for people with disabilities or simply for convenience
Electrified Products TABLE OF CONTENTS. Power Transfers...12 Pressure Sense Bars...12 Proximity Cards & Keys... 4
TABLE OF CONTENTS A Adjustable Angle Bracket (294/2942)... 6 Angle Brackets (2950 Series)... 9 Armature Mounting Plates (2950 Series)... 7 C Coordinator Mounting Bracket (2950 Series)... 7 Concealed Magnetic
LYNX Touch Series Security Systems
LYNX Touch Series Security Systems Home Automation Guide 800-11309 3/12 Rev. A Z-Wave Programming The LYNX Touch control features Z-Wave technology that is designed to automate devices in a home control
EM6556 e-domotica Mini Switch
EM6556 e-domotica Mini Switch EM6556 e-domotica Mini Switch 2 ENGLISH Table of contents 1.0 Introduction...2 1.1 Functions and features...2 1.2 Packing contents...2 2.0 Using the mini switch...3 2.1 Use
HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15
HomeSafe-Basic VT-PS99E User s Manual PSTN Home Alarm System Page: 1 / 15 Table of Contents 1. Product Overview:... 3 2. Main Functions & Features... 3 3. For Your Safety... 4 4. VT-PS99E Characteristics...
FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
CR9971 2 Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use
ROBERTS Sound for Generations CR9971 2 Band Auto Set Dual Alarm Clock Radio Please read this manual before use Contents Contents... 1 Controls...2-5 Switching on... 6 Setting the time manually... 6 Setting
ELECTRONIC LOCKING SYSTEMS
ELECTRONIC LOCKING SYSTEMS Electronic Locking Systems Electronic locks for display cases, lockers and sliding doors This small intelligent electronic cabinet lock has a wide range of uses. Based on a
Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx
756627xx, 756637xx, 756657xx Documentation Product name: Push button 2-, 3-, 5- gang RTR + display Design: UP (flush-mounting type) ETS search path: Push button / Push button xgang / Push button xgang
Shadow TX(A) Shadow RX
Shadow TX(A) Shadow RX Asset Management and RFID Transmitter Tags Asset Management Receiver The Shadow TX(A) and Shadow RX wireless asset management system is a standalone wireless asset tracking system
RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4
RUST ELECTRONICS LTD Remote Switching Unit RCU-O4 MAINS REMOTE SWITCHING UNIT RCU-O4 The RCU-O4 is a radio remote controlled switching unit that will allow the remote operation of any appropriate electrical
Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
KNX Lighting Control System
KNX Lighting Control System Part 1 - Specification Lighting control system A. The following specification details the minimum standards for performance of components, material and operation of lighting
Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)
INSTRUCTION MANUAL ➏ ➋ ➊ Product Features ➎ ➍ ➌ Built-in wireless Bluetooth 3.0 keyboard Compatible across ios, Android, and Windows, enabling you to mix and match with devices Ultra-thin, lightweight
B/S/H/ Error codes and service programmes PH
1 ERROR CODES AND APPLIANCE MESSAGES... 3 1.1 Complete overview of all error codes (in order)... 3 Automatic switch-off... 3 Display is dark and any individual LEDs are lit... 3 E 005... 3 E 011... 3 E
Setup Guide. A Step-by-Step Guide for Programming and Operating a Complete Lutron RadioRA Wireless Central Home Lighting Control System
Setup Guide A Step-by-Step Guide for Programming and Operating a Complete Lutron RadioRA Wireless Central Home Lighting Control System Note: Please leave this manual with homeowner. Important Application
Z-Wave.Me Wall Controller
Z-Wave.Me Wall Controller ZME_06443: Wall Controller Firmware Version 1.1 1 General Information about Z- Wave Safe: Generally radio systems build a direct link between the transmitter and the receiver.