FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

Size: px
Start display at page:

Download "FL ballasts Electronic dimming. PCA T5 ECO lp Y II, 14 80 W ECO T5"

Transcription

1 EL PCA ECO lp Y II, 1 80 W ECO Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DALI or DSI signal, switchdim or corridorfunction Nominal life up to 100,000 h (at ta 50 C with a failure rate max. 0. % per 1,000 h) Multi-lamp management OEM-specific reserved memory areas 5-year guarantee Interfaces DALI DSI switchdim (with memory function + selectable dimming rate) corridorfunction ( preprogrammed profiles) Integrated SMART interface for function with SMART Sensor 5D 19f and corridorfunction plugs side fixing feature L D 1 Functions Intelligent Temperature Guard (overtemperature protection) Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown) Optimum filament heating in any dimmer setting Disconnection of filament heating from a dimming level of approx. 90 % for maximum energy efficiency (SMART-Heating concept) corridorfunction with ambient light control Automatically triggered emergency lighting value in DC mode, 15 % For emergency lighting systems as per EN 501 Automatic start after replacement of defective lamps Automatic shutdown if the lamp is faulty È Standards, page Wiring diagrams and installation examples, page 8 Ø,1 Technical data Mains voltage range AC voltage range DC voltage range Mains frequency Overvoltage protection Typ. power input on standby Protective hot restart 0 0 V 198 V, V (lamp start 198 V DC) 0 / 50 / 0 Hz 0 V AC, 1 h < 0. W Dimming range % Lamp start possible from 1 % Operating frequency Type of protection Ordering data Type For luminaires with 1 lamp 0.5 s for AC / 0. s for DC ~ 0 10 khz IP0 Article number Packaging, carton Packaging, pallet Weight per pc. PCA 1x1/ ECO lp Y II pc(s). 0 pc(s). 0. kg PCA 1x1/9 ECO lp Y II pc(s). 0 pc(s). 0. kg PCA 1x8/5 ECO lp Y II pc(s). 0 pc(s). 0. kg PCA 1x5/9/80 ECO lp Y II pc(s). 0 pc(s). 0. kg For luminaires with lamps PCA x1/ ECO lp Y II pc(s). 0 pc(s). 0. kg PCA x1/9 ECO lp Y II pc(s). 0 pc(s). 0.0 kg PCA x8/5 ECO lp Y II pc(s). 0 pc(s). 0. kg PCA x5/9 ECO lp Y II pc(s). 0 pc(s). 0.0 kg PCA x80 ECO lp Y II pc(s). 0 pc(s). 0. kg 1

2 Specific technical data Lamp wattage Lamp type Type For luminaires with 1 lamp Article number Dimensions L x W x H Hole spacing D Lamp power Circuit power EEI Current at 50 Hz 0 V λ at 50 Hz 0 V tc point max. Ambient temperature ta 1 x 1 W PCA 1x1/ ECO lp Y II x 0 x 1 mm 50 mm 1 W 1.0 W A1 BAT 0.08 A C C 1 x W PCA 1x1/ ECO lp Y II x 0 x 1 mm 50 mm W 5.5 W A1 BAT 0.1 A C C 1 x 1 W PCA 1x1/9 ECO lp Y II x 0 x 1 mm 50 mm 1 W.0 W A1 BAT 0.11 A C C 1 x W PCA 1x1/9 ECO lp Y II x 0 x 1 mm 50 mm W 5.5 W A1 BAT 0.1 A C C 1 x 9 W PCA 1x1/9 ECO lp Y II x 0 x 1 mm 50 mm 8 W 1.5 W A1 BAT 0.19 A C C 1 x 0 W PCA 1x1/9 ECO lp Y II x 0 x 1 mm 50 mm 0 W.0 W A1 BAT 0.0 A C C 1 x 8 W PCA 1x8/5 ECO lp Y II x 0 x 1 mm 50 mm 8 W 0.5 W A1 BAT 0.1 A C C 1 x 5 W PCA 1x8/5 ECO lp Y II x 0 x 1 mm 50 mm 5 W 58.0 W A1 BAT 0. A C C 1 x 5 W PCA 1x5/9/80 ECO lp Y II x 0 x 1 mm 50 mm 5 W 9.0 W A1 BAT 0.18 A C C 1 x 9 W PCA 1x5/9/80 ECO lp Y II x 0 x 1 mm 50 mm 9 W 5.0 W A1 BAT 0.5 A C C 1 x 55 W PCA 1x5/9/80 ECO lp Y II x 0 x 1 mm 50 mm 55 W 0.0 W A1 BAT 0.8 A C C 1 x 80 W PCA 1x5/9/80 ECO lp Y II x 0 x 1 mm 50 mm 80 W 85.5 W A1 BAT 0.0 A C C 1 x 80 W PCA 1x5/9/80 ECO lp Y II x 0 x 1 mm 50 mm 80 W 85.5 W A1 BAT 0. A C C For luminaires with lamps x 1 W PCA x1/ ECO lp Y II x 0 x 1 mm 50 mm 8 W 0.5 W A1 BAT 0.1 A C C x 18 W PCA x1/ ECO lp Y II x 0 x 1 mm 50 mm W 8.0 W A1 BAT 0.15 A C C x W PCA x1/ ECO lp Y II x 0 x 1 mm 50 mm 5 W 9.5 W A1 BAT 0. A C C x W PCA x1/ ECO lp Y II x 0 x 1 mm 50 mm W 9.0 W A1 BAT 0.1 A C C x 1 W PCA x1/9 ECO lp Y II x 0 x 1 mm 50 mm 1 W 5.5 W A1 BAT 0.1 A C C x W PCA x1/9 ECO lp Y II x 0 x 1 mm 50 mm W 1.0 W A1 BAT 0.1 A C C x 9 W PCA x1/9 ECO lp Y II x 0 x 1 mm 50 mm W 8.0 W A1 BAT 0. A C C x 0 W PCA x1/9 ECO lp Y II x 0 x 1 mm 50 mm 80 W 8.0 W A1 BAT 0.0 A C C x 8 W PCA x8/5 ECO lp Y II x 0 x 1 mm 15 mm 5 W 0.5 W A1 BAT 0.8 A C C x 5 W PCA x8/5 ECO lp Y II x 0 x 1 mm 15 mm 108 W 11.5 W A1 BAT 0.51 A C C x 5 W PCA x5/9 ECO lp Y II x 0 x 1 mm 50 mm 0 W.5 W A1 BAT 0. A C C x 9 W PCA x5/9 ECO lp Y II x 0 x 1 mm 50 mm 98 W W A1 BAT 0.9 A C C x 55 W PCA x80 ECO lp Y II x 0 x 1 mm 15 mm 110 W 11.0 W A1 BAT 0.5 A C C x 80 W PCA x80 ECO lp Y II x 0 x 1 mm 15 mm 10 W 1.0 W A1 BAT 0. A C C 1 According to the EU directives on ecodesign requirements (EC) No. 5/009 and (EC) No. /010. Valid at 100 % dimming level. +10 C to ta max: unrestricted dimming. -5 C to +10 C: unrestricted dimming from 100 % to 0 %. -5 C to +10 C, dimming below 0 %: malfunction possible but no damage to ECG. This applies to AC and DC operation.

3 Standards EN EN 099 EN EN 1-- EN 15 Suitable for emergency installations according to EN 501 CISPR 15 CISPR IEC 099 IEC IEC 1-- IEC 15 IEC 8 (according to DALi standard V1) Lamp starting characteristics Warm start Starting time 0.5 s with AC Starting time 0. s with DC Start at any dimming level AC operation Mains voltage 0 0 V 50/0 Hz 198 V 50/0 Hz including safety tolerance (±10 %) V 50/0 Hz including performance tolerance (+ % / -8 %) Mains currents in DC operation (at 15 % light output) Mains current at Mains current at Type Lamp type Wattage Un = 0 VDC Un = 5 VDC PCA 1x1/ ECO lp Y II 1 x 1 W 0.0 A 0.0 A 1 x W 0.05 A 0.05 A 1 x 1 W 0.05 A 0.0 A PCA 1x1/9 ECO lp Y II 1 x W 0.0 A 0.0 A 1 x 9 W 0.0 A 0.0 A 1 x 0 W 0.0 A 0.0 A PCA 1x8/5 ECO lp Y II 1 x 8 W 0.0 A 0.0 A 1 x 5 W 0.11 A 0.10 A 1 x 5 W 0.0 A 0.0 A 1 x 9 W 0.09 A 0.08 A PCA 1x5/9/80 ECO lp Y II 1 x 55 W 0.11 A 0.10 A 1 x 80 W 0.1 A 0.1 A 1 x 80 W 0.1 A 0.1 A x 1 W 0.0 A 0.0 A PCA x1/ ECO lp Y II x 18 W 0.0 A 0.0 A x W 0.10 A 0.09 A x W 0.09 A 0.09 A x 1 W 0.08 A 0.0 A PCA x1/9 ECO lp Y II x W 0.1 A 0.11 A x 9 W 0.1 A 0.1 A x 0 W 0.1 A 0.1 A PCA x8/5 ECO lp Y II x 8 W 0.10 A 0.10 A x 5 W 0.0 A 0.18 A PCA x5/9 ECO lp Y II x 5 W 0.1 A 0.11 A x 9 W 0.1 A 0.15 A PCA x80 ECO lp Y II x 55 W 0.0 A 0.19 A x 80 W 0. A 0.5 A DC operation 0 0 V 0 Hz V 0 Hz certain lamp start 1 80 V 0 Hz operating range Use in emergency lighting installations according to EN 501 or for emergency luminaires according to EN 1-- appendix J. Mains current for defective or missing lamps at DC operation < 5 ma. Light output level in DC operation Default value is 15 % Emergency units The PCA ECO lp y II ballasts are compatible with all emergency units from Tridonic. See the table in the data sheet. Also all 5-pole emergency units can be used. When used with other emergency units tests are necessary. Temperature range Unlimited dimming range from 10 C to ta max. -5 C to 10 C: dimming operation from 100 % to 0 %. If dimm level goes below 0 % malfunction possible, but no electronic ballast damage. This applies to AC and DC operation. Ballast lumen factor AC operation (AC-BLF) EN Type Lamp type Wattage AC-BLF at U = 0 VAC PCA 1x1/ ECO lp Y II 1 x 1 W x W x 1 W 0.99 PCA 1x1/9 ECO lp Y II 1 x W x 9 W x 0 W 1.05 PCA 1x8/5 ECO lp Y II 1 x 8 W x 5 W x 5 W x 9 W 1.00 PCA 1x5/9/80 ECO lp Y II 1 x 55 W x 80 W x 80 W 1.0 x 1 W 1.01 PCA x1/ ECO lp Y II x 18 W 0.90 x W 1.00 x W 0.98 x 1 W 0.9 PCA x1/9 ECO lp Y II x W 0.9 x 9 W 0.98 x 0 W 1.05 PCA x8/5 ECO lp Y II x 8 W 1.00 x 5 W 1.00 PCA x5/9 ECO lp Y II x 5 W 1.01 x 9 W 1.0 PCA x80 ECO lp Y II x 55 W 1.0 x 80 W 1.0 The ballast lumen factor for AC operation (AC-BLF) does not alter from Un = 198 V AC to Un = 5 V AC. The ballast lumen factor for DC operation (DC-BLF) on the basis of an automatic power reduction of the ballasts (default value is 15 %) will be smaller than AC. It does not alter in the DC operating range (198 V DC).

4 Dimming Dimming curve is adapted to the eye sensitiveness. Dimming range 1 % to 100 % Digital control with: DSI signal: 8 bit Manchester Code Speed 1 % to 100 % in 1. s DALI signal: 1 bit Manchester Code Maximum speed 1 % to 100 % in 550 ms (adjustable between 100 ms and 90 s) Programmable parameter: Minimum dimming level Maximum dimming level Default minimum = 1 % Default maximum = 100 % Control input (DA/D1, DA/D) Digital DALI/DSI signal or a push-to-make switch (switchdim) or a motion detector (corridorfunction) can be wired on the same terminals (DA/D1 and DA/ D). Digital signal DALI/DSI The control input is non-polar and protected against accidental connection with a mains voltage up to V. The control signal is not SELV. Control cable has to be installed in accordance to the requirements of low voltage installations. Different functions depending on each module. SMART interface An additional interface for the direct connection of the SMART-Sensor 5D 19f 1) or corridorfunction plugs. Application and functionallity see corridorfunction user manual. SMART-Sensor 5D 19f 1) light sensor operating mode: The sensor registers actual ambient light and maintains the individually defined constant lux level. After every mains reset the SMART interface automatically checks for an installed sensor. With the sensor installed the PCA ECO lp y II automatically runs in the constant lux level mode. ON/OFF switch via mains, switchdim or DSI signal. DSI signal = 0 switches off, DSI signal 1 switches on. With switchdim signals it is possible to change the controlled light level temporarily. Temporarily means that after a switching cycle OFF/ ON command the ballast will start at the preset value determined by the SMART-Sensor 5D 19f. The installation of the two wire bus is according to the appropriate low voltage regulations. 1) SMART-Sensor 5D 19f: article number switchdim Integrated switchdim function allows a direct connection of a push to make switch for dimming and switching. Brief push (< 0. s) switches ballast ON and OFF. The ballasts switch-on at light level set at switch-off. After switch ON the last settet dimming level will be activated again. When the push to make switch is held, PCA ballasts are dimmed. After repush the PCA is dimmed in the opposite direction. The switchdim fade time is set to s from min. to max. in the factory settings. With a 0 s push to the push to make switch this fade time can be changed to s. In this instance the switchdim application will be synchronized to 50 % light level after 10 s and after 0 s the light level rises to 100 % with the new fade Dimming characteristics PCA ECO lp Y II digital dimming value DALI 15 DSI relative lighting level in % Dimming characteristics as seen by the human eye time. At every synchronizsation (10 s keystroke) the device will reset to s (factory setting) In installations with PCAs with different dimming levels or opposite dimming directions (e.g. after a system extension), all PCAs can be synchronized to 50 % dimming level by a 10 s push. Use of push to make switch with indicator lamp is not permitted. switchdim and corridorfunction are very simple tools for controlling ballasts with conventional momentaryaction switches or motion sensors. To ensure correct operation a sinusoidal mains voltage with a frequency of 50 Hz or 0 Hz is required at the control input. Special attention must be paid to achieving clear zero crossings. Serious mains faults may impair the operation of switchdim and corridorfunction. corridorfunction To activate the corridorfunction a voltage of 0 V simply has to be applied for five minutes at switchdim connection. The unit will then switch automatically to the corridorfunction. Note: If the corridorfunction is wrongly activated in a switchdim system (for example a switch is used instead of pushbutton), there is the option of installing a pushbutton and deactivating the corridorfunction mode by five short pushes of the button within three seconds. The corridorfunction offers the added benefit of a second and third preprogrammed profile, which can be activated by the corridorfunction plugs. It is also possible to combine the corridorfunction with the SMART-Sensor 5D 19f light sensor. Application and functionallity of profiles see user manual of the corridorfunction. Energy saving PCA ECO lp Y II mains power in % dimming level in % switchdim PCA ECO lp Y II DSI N L DSI PCA ECO lp Y II DALI N L DALI PCA ECO lp Y II D1 D D1 D corridorfunction PCA ECO lp Y II D1 D DA DA

5 Loading of automatic circuit breakers (Limitation via inrush current) Automatic circuit breaker type C10 C1 C1 C0 B10 B1 B1 B0 Inrush current (1.5 mm ) Inrush current (.5 mm ) Installation Ø 1.5 mm 1.5 mm 1.5 mm.5 mm 1.5 mm 1.5 mm 1.5 mm.5 mm I max time I max time PCA 1x1/ ECO lp Y II A 1 µs 19. A 1 µs PCA 1x1/9 ECO lp Y II A 190 µs 5.1 A 19 µs PCA 1x8/5 ECO lp Y II A 5 µs 8.5 A µs PCA 1x5/9/80 ECO lp Y II A 1 µs 1. A µs PCA x1/ ECO lp Y II A µs 8. A µs PCA x1/9 ECO lp Y II A 0 µs 8.8 A 0 µs PCA x8/5 ECO lp Y II A 88 µs 0. A 8 µs PCA x5/9 ECO lp Y II A 1 µs.9 A 0 µs PCA x80 ECO lp Y II A 1 µs 50.1 A 58 µs Continuous operation: to calculate the protective saftey switch see main current, page Intelligent Voltage Guard Intelligent Voltage Guard is the name of the electronic monitor from Tridonic. This inno vative feature of the PCA family of control gear from Tridonic immediately shows if the mains voltage rises above certain thresholds. Measures can then be taken quickly to prevent damage to the control gear. If the mains voltage rises above approx. 18 Vrms (voltage depends on the ballast type), the lamp starts flashing on and off. To avoid a damage of the device the mains supply has to be switched off at this signal. Intelligent Temperature Guard The intelligent temperature guard protects the PCA ECO lp y II from thermal overheating by reducing the output power or switching off in case of operation above the thermal limits of the luminaire or ballast. Depending on the luminaire design, the ITG operates at about 5 to 10 C above tc temperature. 5

6 Harmonic distortion in the mains supply (at 0 V / 50 Hz) Type Lamp type Wattage THD PCA 1x1/ ECO lp Y II 1 x 1 W x W x 1 W 9 PCA 1x1/9 ECO lp Y II 1 x W x 9 W x 0 W PCA 1x8/5 ECO lp Y II 1 x 8 W 10 1 x 5 W x 5 W 10 1 x 9 W 10 8 PCA 1x5/9/80 ECO lp Y II 1 x 55 W x 80 W x 80 W x 1 W PCA x1/ ECO lp Y II x 18 W x W x W x 1 W 10 PCA x1/9 ECO lp Y II x W x 9 W x 0 W PCA x8/5 ECO lp Y II x 8 W 10 x 5 W PCA x5/9 ECO lp Y II x 5 W x 9 W PCA x80 ECO lp Y II x 55 W x 80 W Operating voltage Type Lamp type Wattage Uout PCA 1x1/ ECO lp Y II PCA 1x1/9 ECO lp Y II PCA 1x8/5 ECO lp Y II PCA 1x5/9/80 ECO lp Y II PCA x1/ ECO lp Y II PCA x1/9 ECO lp Y II PCA x8/5 ECO lp Y II PCA x5/9 ECO lp Y II PCA x80 ECO lp Y II 1 x 1 W 0 V 1 x W 0 V 1 x 1 W 0 V 1 x W 0 V 1 x 9 W 0 V 1 x 0 W 0 V 1 x 8 W 0 V 1 x 5 W 0 V 1 x 5 W 0 V 1 x 9 W 0 V 1 x 55 W 0 V 1 x 80 W 0 V 1 x 80 W 0 V x 1 W 0 V x 18 W 0 V x W 0 V x W 0 V x 1 W 0 V x W 0 V x 9 W 0 V x 0 W 0 V x 8 W 0 V x 5 W 0 V x 5 W 0 V x 9 W 0 V x 55 W 0 V x 80 W 0 V

7 Humidity: 5 % up to max. 85 %, not condensed (max. 5 days/year at 85 %) Storage temperature: -0 C up to max. +80 C The devices have to be within the specified temperature range (ta) before they can be operated. Expected life-time Type Lamp type Wattage ta = 0 C ta = 50 C ta = 0 C PCA 1x1/ ECO lp Y II PCA 1x1/9 ECO lp Y II PCA 1x8/5 ECO lp Y II PCA 1x5/9/80 ECO lp Y II PCA x1/ ECO lp Y II PCA x1/9 ECO lp Y II PCA x8/5 ECO lp Y II PCA x5/9 ECO lp Y II PCA x80 ECO lp Y II x = not permitted 1 x 1 W 1 x W 1 x 1 W 1 x W 1 x 9 W 1 x 0 W 1 x 8 W 1 x 5 W 1 x 5 W 1 x 9 W 1 x 55 W 1 x 80 W 1 x 80 W x 1 W x 18 W x W x W x 1 W x W x 9 W x 0 W x 8 W x 5 W x 5 W x 9 W x 55 W x 80 W tc 50 C 0 C 0 C tc 50 C 0 C 0 C tc 50 C 0 C 0 C Life-time > 100,000 h > 100,000 h 90,000 h tc 55 C 0 C 0 C tc 5 C 0 C 80 C Life-time > 100,000 h > 100,000 h 50,000 h tc 5 C 0 C 80 C Life-time > 100,000 h > 100,000 h 50,000 h tc 5 C 0 C 80 C Life-time > 100,000 h > 100,000 h 50,000 h tc 50 C 0 C 0 C Life-time > 100,000 h > 100,000 h 90,000 h Life-time > 100,000 h > 100,000 h 90,000 h Life-time > 100,000 h > 100,000 h 90,000 h tc 0 C 0 C 80 C Life-time > h > h h tc 0 C 0 C 80 C Life-time > h > h h tc 0 C 0 C 80 C Life-time > h > h h tc 55 C 0 C 0 tc 5 C 5 C x Life-time > 100,000 h 0,000 h x Life-time > 100,000 h > 100,000 h 80,000 h tc 5 C 5 C 80 C Life-time > 100,000 h 80,000 h 50,000 h tc 5 C 5 C x Life-time > 100,000 h 80,000 h x tc 5 C 0 C x Life-time > 100,000 h 80,000 h x

8 Installation instructions Wiring type and cross section The wiring can be solid cable with a cross section of 0.5 to 0.5 mm² for push terminal and 0.5 mm² for IDC terminal. For the push-wire connection you have to strip the insulation (8 9 mm). wire preparation: mm² Wiring advice The lead length is dependent on the capacitance of the cable. Ballast Terminal Maximum capacitance allowed Type Cold Hot Cold Hot PCA 1xx ECO lp Y II 1, 1 15, 1 00 pf 100 pf PCA xx ECO lp Y II 1, 1, 1 10, 11, 15, 1 00 pf 100 pf 8 9 mm Loosen wire through twisting and pulling With standard solid wire 0.5/0.5 mm² the capacitance of the lead is 0 80 pf/m. This value is influenced by the way the wiring is made. Lamp connection should be made with symmetrical wiring. Hot leads (10, 11, 15, 1) and cold leads (1, 1, 1) should be separated as much as possible. When using two or more dimmable ballasts in one luminaire with separate dimming controls, the lamp leads must be kept separate. Sensor wires Sensor wires must be routed separately from the lamp wires and mains cables otherwise the lighting control system may malfunction. If separate routing is not possible (for reasons of space) shielded lamp wires and mains cables must be used. Dimmable ballasts from Tridonic have to be earthed. * * control signal DA/D1 DA/D * * control signal DA/D1 DA/D PCA ECO lp Y II 1x1 80 W * leads 15, 1: keep wires short, max. 1.0 m leads 1, 1: max..0 m; ballast must be earthed * * digital signal (DSI), DALI or switchdim * leads 10, 11, 15, 1: keep wires short, max. 1.0 m leads 1, 1, 1: max..0 m; ballast must be earthed * * digital signal (DSI), DALI or switchdim PCA ECO lp Y II x1 80 W Dimmable ballasts from Tridonic have to be earthed. RFI Connection to the lamps of the hot leads must be kept as short as possible Mains leads should be kept apart from lamp leads (ideally 5 10 cm distance) Do not run mains leads adjacent to the electronic ballast Twist the lamp leads Keep the distance of lamp leads from the metal work as large as possible Mains wiring to be twisted when through wiring Keep the mains leads inside the luminaire as short as possible General advise Electronic ballasts are virtually noise free. Magnetic fields generated during the ignition cycle can cause some background noise but only for a few milliseconds. Operation on DC voltage Our ballasts are construed to operate DC voltage and pulsed DC voltage. To operate ballasts with pulsed DC voltage the polarity is absolute mandatory. + D1 D Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC Annex Q (informative only!) or ENEC 0-Annex A, each luminaire should be submitted to an isolation test with 500 VDC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least MΩ. As an alternative, IEC Annex Q describes a test of the electrical strength with 1500 VAC (or 1.1 x 1500 VDC). To avoid damage to the electronic devices this test must not be conducted. For further technical information please visit 8

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5 T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,

More information

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, 14 80 W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, 14 80 W EXCEL T5 E T5 TC- PCA T5 EXCE oneall lp Y II, 1 80 W EXCE T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via I or

More information

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5 F ballasts T PCA T EXCE oneall lp Y, x1/ W and x1/ W EXCE T Product description Processor-controlled ballast with y inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps EXCEL oneall series Product description Noise-free precise control via DSI signal, switchdim, corridorfunction or DALI DALI-MEMORY Extended DALI commands CELMA energy class A1 1) Interfaces DALI DSI switchdim

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, 18 80 W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, 18 80 W Compact and T5c fluorescent lamps Product description Noise-free precise control via DSI signal or switchdim CELMA energy class A1 1) Interfaces DSI switchdim Integrated SMART-Interface Functions Optimum filament heating in any dimmer

More information

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W T5 TC-DEL TC-SEL TC-TEL TC-DD PC BASIC, 4 28 W Electronic ballast for system output < 25 W Product description CELMA Energy Efficiency Index A2 / A3 Nominal life time up to 50,000 h (at ta 50 C with a

More information

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series Product description Independent dimmable LED control gear Constant current LED control gear Output current adjustable between 900 1,750 ma Max. output

More information

LED Driver Compact dimming. Udriver LCAI 35W 350mA 900mA ECO C ECO series

LED Driver Compact dimming. Udriver LCAI 35W 350mA 900mA ECO C ECO series Udriver LCAI 35W 350mA 900mA ECO C ECO series Product description Dimmable built-in LED Driver for LED Constant current LED Driver Output current adjustable between 350 900 ma Max. output power 35 W Nominal

More information

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series Udriver LCAI 100W 900mA 1750mA ECO SR ECO series Product description Independent dimmable LED Driver Constant current LED Driver Output current adjustable between 900 1,750 ma Max. output power 100 W Suitable

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year

More information

LED control gear. LED control gear

LED control gear. LED control gear Overview System overview Product overview compact Product overview linear / area Product overview constant voltage / constant current Product / function matrix Page 10 Page 12 Page 13 Page 14 Page 15 Compact

More information

LED light engine / OLED LED compact. Uengine STARK DLE PREMIUM system data sheet STARK DLE

LED light engine / OLED LED compact. Uengine STARK DLE PREMIUM system data sheet STARK DLE Uengine STARK DLE PREMIUM system data sheet STARK DLE Product description Tunable white system with adjustable colour temperature along the planck s curve from 2.700 to 6.500 K NEW LI DEVICE Type 8 for

More information

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens 270-1250 CLASSIC umodule QLE

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens 270-1250 CLASSIC umodule QLE Umodule STARK QLE G3 lens 27-125 CLASSIC umodule QLE Product description Ideal for linear and panel lights Luminous flux range from 1, 1,21 lm LED system solution with outstanding system efficacy up to

More information

basicdim DGC Compact control module

basicdim DGC Compact control module luxctrol lighting control sstem DGC Compact control module Product description Compact dimensions for luminaire installation For up to 0 DSI or LI ballasts ( per output channel) LI IN input LI/DSI output

More information

LED light engine / OLED LED compact. Umodule STARK CLE 120-2000 CLASSIC / CLE 130-2500 CLASSIC umodule CLE

LED light engine / OLED LED compact. Umodule STARK CLE 120-2000 CLASSIC / CLE 130-2500 CLASSIC umodule CLE Umodule STARK CLE 12-2 CLASSIC / CLE 13-25 CLASSIC umodule CLE Product description Designed for diffuser downlights and wallmounted luminaires Ideal to realise simple luminarie designs For easy adaptation

More information

Digital gear for fluorescent lamps

Digital gear for fluorescent lamps Catalogue 2000/2001 Digital gear for fluorescent lamps Comprehensive range of literature available: Magnetic control gear for fluorescent lamps Control gear for high pressure discharge lamps Transformers

More information

Installation and User Guide

Installation and User Guide Installation and User Guide 458-UNI8 8-Channel Universal Dimmer Module Introduction The 458/UNI8 is an 8-channel universal, digital transistor, dimmer module. Each channel s mode can be selected for either

More information

PWM-90 series IP67 TRC ELECTRONICS, INC. 1.888.612.9514. www.trcelectronics.com/meanwell. Mean Well PWM-90 Series

PWM-90 series IP67 TRC ELECTRONICS, INC. 1.888.612.9514. www.trcelectronics.com/meanwell. Mean Well PWM-90 Series TRC ELECTRONICS, INC. 90W PWM output LED power LED supply Power Supply Constant Voltage PFC High Efficiency 90W Ⅱ Ⅱ IP67 TRC ELECTRONICS, INC. 90W PWM output LED power supply SPECIFICATION MODEL OUTPUT

More information

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

DALI RC BASIC SO. Control unit Operating instructions

DALI RC BASIC SO. Control unit Operating instructions DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness

More information

PWM-60 series IP67 TRC ELECTRONICS, INC. 1.888.612.9514. www.trcelectronics.com/meanwell

PWM-60 series IP67 TRC ELECTRONICS, INC. 1.888.612.9514. www.trcelectronics.com/meanwell 60W PWM output LED power supply Ⅱ IP67 Ⅱ TRC ELECTRONICS, 60W PWM output INC. LED power supply SPECIFICATION MODEL OUTPUT INPUT PROTECTION DC VOLTAGE RATED CURRENT RATED POWER DIMMING RANGE PWM FREQUENCY

More information

DIGITAL CONTROLS OVERVIEW

DIGITAL CONTROLS OVERVIEW DIGITAL CONTROLS OVERVIEW START Phase Cutting Dimmers Analogue Dimming switchdim corridorfunction DSI Dimming Dali Dimming Dali-Ag PIR Wiring Diagram s Wiring Diagram s Wiring Diagram s Wiring Diagram

More information

LED light engine / OLED LED linear /area. Umodule STARK LLE-24-560-1300 CLASSIC STARK LLE. Ordering data

LED light engine / OLED LED linear /area. Umodule STARK LLE-24-560-1300 CLASSIC STARK LLE. Ordering data Ideal for linear and panel lights Luminous flux range from 1,25 1,57 lm LED system solution with outstanding system efficacy up to 113 lm/w, consisting of linear LED module and dimmable LED control gear

More information

Operating instructions IV / 2007

Operating instructions IV / 2007 General Operating instructions IV / 2007 Contents General Installation Application and function Application and function... 2 Safety information... 2 Design and dimensions... 3 Wiring diagram... 3 Installation

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors APPENDIX APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS RJ12 connectors Pin # 1 Signal Name Not Used 2 +TR Description + Data Line 3 +R Remote OFF Required or Remote OFF control 4 -TR 5 Not Used 6 RTN -

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE w LED light engine / OLED Product description For general lighting application Typ. luminous flux category: 3/6/8/1,2 lm High efficacy up to 133 lm/w for the LED module at tp = 25 C Small LES (light emitting

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Busch-Watchdog Presence EIB Type: 6131-74-102-500

Busch-Watchdog Presence EIB Type: 6131-74-102-500 Type: 6131-74-102-500 Contents Technical data 2-2 Application programs (List) 2-3 Circuit diagrams 2-3 in combination with Bus coupler FM (6120-102): Switch Value Cyclic Monitoring /3 2-4 Switch Value

More information

connecdim Gateway G1 Ethernet TCP/IP to DALI

connecdim Gateway G1 Ethernet TCP/IP to DALI Gateway G1 Ethernet TCP/IP to LI Independent lighting control for up to 256 LI gears on 4 LI lines Can be expanded by connecting multiple gateways on the same network Cloud based web interface for configuration

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

OPTOTRONIC LED Power Supply OT180W/UNV/800C/2DIMLT2/P6 - Technical Specifications

OPTOTRONIC LED Power Supply OT180W/UNV/800C/2DIMLT2/P6 - Technical Specifications www.osram-americas.com/optotronic OPTOTRONIC LED Power Supply OT180W/UNV/800C/2DIMLT2/P6 - Technical Specifications GENERAL INFORMATION Item Number 79366 ELECTRICAL SPECIFICATIONS Input Input Voltage (VAC)

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

EBDSPIR-DD, EBDSPIR-DD-IP

EBDSPIR-DD, EBDSPIR-DD-IP Product Guide EBDSPIR-DD, EBDSPIR-DD-IP Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSPIR-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide Digidim 458/DIM8 8-Channel Dimmer Module Installation and User Guide Introduction The 458/DIM8 is an 8-channel digital thyristor dimmer module, for leading-edge dimming of resistive and inductive loads.

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX SA/S Switch Actuators Product Manual ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

Nominal Power [W] Radiance Angle [ ] Color Temp. [K]

Nominal Power [W] Radiance Angle [ ] Color Temp. [K] PrevaLED COIN 111 G2 Technical Information Benefits Fits in most existing R111 traditional luminaires Easy & fast design-in for luminaire manufacturers Narrow beam angles, 24 o and 40 o High lumen output

More information

Operating instructions II / 2004

Operating instructions II / 2004 Operating instructions II / 2004 Light and presence sensor TOUCH DIM LS/PD LI OSRAM GmbH Costumer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany www.osram.com www.osram.de Tel. : (+49)

More information

O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications

O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications Features UniversalACinput/Fulrange Built-inactivePFCfunction Higheficiencyupto91% Protections:Shortcircuit/Overcurent/ Overvoltage/Overtemperature Fanlesdesign,colingbyfreairconvection Colingbyfreairconvection

More information

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10 ABB ABB Schweiz AG Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205 09.04.2014 Page: 8201 Schaffhausen 1 / 10 Please use also the assembly instruction S800-RSU-H Remote

More information

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology Tilt switches MEMS technology, one or two axis N3 / N4... + long lifetime and highly reliability due to mechanism-free MEMS technology + combinable output signals + one or two axis measurement + tilt range

More information

DALI-PWM Signal Converter D A P-04. Applications. Features

DALI-PWM Signal Converter D A P-04. Applications. Features SELV Bauar t gepruf t Sich erheit egelma ge od o s b e wac g ww w. tuv.com ID 000000000 Features Universal AC input / Full range ( up to 305VAC) Convert DALI signal to PWM signal DALI addressable output

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Compact design Excellent thermal management 1 NTC for temperature control High-power LED in chip-on-board

More information

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC 42.25 37 11 5.75 3.5 5.15 37.89 39.

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC 42.25 37 11 5.75 3.5 5.15 37.89 39. Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Compact design Excellent thermal management 1 NTC for temperature control High-power LED in chip-on-board

More information

STRATO LED Drivers 70W, Single output

STRATO LED Drivers 70W, Single output Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

AC3200 INTELLIGENT BROADBAND AMPLIFIER

AC3200 INTELLIGENT BROADBAND AMPLIFIER Kari Mäki 9.4.2013 1(7) AC3200 INTELLIGENT BROADBAND AMPLIFIER AC3200 is the latest leading-edge addition to AC family with extended frequency and gain ranges and integrated electrical controls in both

More information

IVIOS LED III. LUM Technical Information

IVIOS LED III. LUM Technical Information LUM Technical Information Extremely flat high power LED downlights with splashing water protection (IP44). Ideal for substituting traditional CFL and halogen downlights with wide beam angle. Tender text

More information

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit) 000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

650W Single Output Power Supply

650W Single Output Power Supply AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

COOL Shelf Quick Connect

COOL Shelf Quick Connect Refrigeration equipment Shelf lighting High efficiency COOL QCS Quick-Connection-System Dimmable Various lengths Neutral White Warm White Pasta & Cheese Fresh Meat Packed Meat 1 A COOL Shelf Quick Connect

More information

Radiance Angle [ ] Nominal Power [W] Color Temp. [K]

Radiance Angle [ ] Nominal Power [W] Color Temp. [K] PrevaLED COIN 111 Technical Information Benefits Fits in most existing R111 traditinoal luminaires Easy & fast design-in for luminaire manufacturers Narrow beam angles, 24 o and 40 o High lumen output

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

LED DIMMING A HELPFUL GUIDE...

LED DIMMING A HELPFUL GUIDE... LED DIMMING A HELPFUL GUIDE... Introduction There are five types of dimming control interfaces described in this document: 2-Wire Forward Phase, 2-Wire Reverse Phase, 3-Wire (Lutron), 4-Wire (0 10V), and

More information

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions Compact presence detector Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

LED Driver: LT10. EuP2. Features. Approvals IP20. Markets & Applications. Engineering Drawing. Technical Data

LED Driver: LT10. EuP2. Features. Approvals IP20. Markets & Applications. Engineering Drawing. Technical Data LED Driver: LT10 LT10-16 1-15 VDC 700 ma 1895089 LT10-32 2-30 VDC 350 ma 1895008 High Efficiency: Typ. 83% Low Standby Losses 0,2W LED Driver: LT10 DB LT10-16 1-15 VDC 700 ma 1895542 LT10-32 2-30 VDC 350

More information

Preset Counter signo 721

Preset Counter signo 721 Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage

More information

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES 4 A CAPACITY, THE VARIETY OF CONTACT ARRANEMENTS S RELAYS FEATURES 28. 1.12 12..472 1.4.49 The variety of contact arrangements 2 Form A 2 Form B, 3 Form A 1 Form B, 4 Form A Latching types available High

More information

Maximum Input Current Vin=18V, 100% Load 12.6 13.1 A

Maximum Input Current Vin=18V, 100% Load 12.6 13.1 A FEATURES Wide input voltage range, 18~60V 200W Output @ 18V~27V Vin range 300W Output @ 27~60V Vin range (Including 27V) Full Load Efficiency up to 88.3% @48Vin Intergrated fuse holder Parallel Connection

More information

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models TML Series, 0 & 0 Watt Features C B Scheme LVD UL 090- Encapsulated power supplies with increased power density Replaces TML and TML 0 series PCB mount or chassis mount with screw terminals Single, dual

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

ST Series POWER SUPPLIES USER INSTRUCTIONS

ST Series POWER SUPPLIES USER INSTRUCTIONS Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional

More information

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer) Operating Manual for the Electronic Built-in Interval Timer Micro II (Countdown Timer) Note: This document has been designed for our OEM customers. They can use it as supporting material when creating

More information

I STAR COMPUTER CO., LTD

I STAR COMPUTER CO., LTD I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON

More information

Radiance Angle [ ] Color Temp. [K]

Radiance Angle [ ] Color Temp. [K] PrevaLED COIN 50 Technical Information Benefits Fits in most existing MR16 traditional luminaires Easy & fast design-in for luminaire manufacturers Narrow beam angles, 24 o and 40 o High lumen output for

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB , GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat FREEZE Freezer equipment Canopy lighting High efficiency QCS Quick-Connection-System Dimmable Various lengths Daylight Neutral White Fresh Meat Packed Meat 1 A FREEZE Canopy PRODUCT DESCRIPTION 19.8 mm

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

400-800. Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

400-800. Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction*** INPUT Input protection Thermal protection Switching frequency internal fuse standard 100KHz Input with PFC : (MML400PFC, MML600, MML800) Input voltage range 85*-264VAC Inrush current (peak) MML400PFC

More information

Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0

Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0 The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection,

More information

SMART SENSOR COLLECTION

SMART SENSOR COLLECTION TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8

More information

Model EC5111 Speed Controller Isochronous / Droop

Model EC5111 Speed Controller Isochronous / Droop R Conforms to EC Directive on Electromagnetic Compatibility ADVANT ANTAGE SERIES Quality System Certification Model EC5111 Speed Controller Isochronous / Droop Features Isochronous or Droop governing Rugged,

More information

Rated Lumen [lm] Nominal. Volts [V] [lm]

Rated Lumen [lm] Nominal. Volts [V] [lm] GE Lighting rcstream Metal Halide lamps Tubular Clear 25W and W Elliptical Diffuse 25W DT SHEET Product information High brightness, high quality white light with good colour rendition and energy efficiency

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S 2.300.2. Intelligent Installation Systems ABB

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S 2.300.2. Intelligent Installation Systems ABB Product Manual ABB i-bus KNX Universal Dim Actuator, MDRC UD/S 2.300.2 Intelligent Installation Systems ABB UD/S 2.300.2 Universal Dim Actuator, MDRC This manual describes the function of the Universal

More information

The most sustainable lighting solution. QL 85W Induction Lighting System

The most sustainable lighting solution. QL 85W Induction Lighting System The most sustainable lighting solution QL 85W Induction Lighting System QL Induction Lighting Systems QL induction lighting is used for professional, general and special lighting applications because of

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information