KNX Powerline PL 110. KNX Association
|
|
|
- Jared Harrell
- 9 years ago
- Views:
Transcription
1 KNX Powerline PL 110
2 Table of Contents 1 Introduction Standardisation Transmission Process Phase Coupling Telegram Transmission Training Sequence Preamble field Telegram System ID Reply Telegram Installations without System Coupler Installations with System Coupler Bus Access Procedure Topology / Addressing KNX PL 110 System Devices Mains Coupler Mains Coupler and Compact Devices in Flush-mounted Design Surface-mounted Design DIN Rail Mounted Design Adapter Phase Coupler System Coupler Band-stop Filter Mains Cables Information for Planners, Project Designers and Installers KNX Powerline PL 110 Powerline_E0307d 2/17
3 NOTE: THIS CHAPTER IS INTENDED TO BE USED AS INFORMATIVE ANNEX TO BASIC COURSES. THE CONTENTS IS NOT PART OF THE EXAM AT THE END OF THE BASIC COURSE. 1 Introduction KNX PL 110 allows the transmission of telegrams across the 230/400 V network. A separate bus line is therefore not necessary. Telegram transmission takes place via external and neutral conductors which must be connected to every device. KNX PL 110 is compatible with KNX TP1 components and the corresponding tools. It is possible for instance to plug a flush-mounted application module onto a flush-mounted mains coupler and to load the application software via the bus cable (230/400 V supply line) into the mains coupler. In spite of the undefined transmission characteristics of the energy supply system (caused by cable types, cable length, type and number of connected devices ), KNX PL 110 ensures a high level of security during telegram transmission. KNX PL 110 works bidirectionally in a half-duplex operation i.e. every device can transmit and receive. Typical KNX PL 110 applications are: control (switching, dimming) of lighting installations motor-driven applications (shutters, opening gates) alarms transmission of analogue values time or central control presence simulation visualisation with touch-sensitive displays Owing to the undefined network conditions, telegram transmission may be interrupted. For this reason, it is not permitted to realise applications with KNX PL 110 whereby the absence of a telegram can lead to extensive consequential damage. Such applications are for example lift control and emergency devices. 2 Standardisation In Europe, signal transmission via the energy supply system is regulated by the CENELEC standard EN Part 1 of this standard defines general requirements, frequency ranges, transmission levels and requirements for electromagnetic compatibility (EMC). KNX PL 110 uses the frequencies khz and khz for transmission. Due to the middle frequency of 110 khz, the KNX PL 110 system is sometimes referred to as PL110. As the standard only allows a maximum transmission level of 116 dbµv, the devices are sometimes called class 116 devices. KNX Powerline PL 110 Powerline_E0307d 3/17
4 3 Transmission Process Figure 1: Transmission process Owing to the continuous progress made in the miniaturisation of electronics, it was possible to apply a new transmission process for KNX PL 110 i.e. Spread Frequency Shift Keying or SFSK for short. It functions as follows: If a 0 is transmitted, the transmitter produces a frequency of khz and the supply voltage are superimposed. If a 1 is transmitted, a frequency of khz is used. In order to ensure a safe transmission at the highest possible speed, the rate of 1200 bit/s is set in all mains couplers which corresponds to a bit duration of 833 µs. All mains couplers are permanently in receive mode. A received signal (also noise) is permanently converted into a digital value. This digital value is now fed into two correlators (probability comparators) which compare the received digital value with a stored, digital frequency reference pattern. There are two correlators in each mains coupler: one for the 0 bit and one for the 1 bit. The correlators can differentiate with a calculable probability that: - it is a 0 - it is a 1 - it is undefined (noise) and the bit is therefore rejected. The combination of bit patterns as well as the specialised error detection methods allows a guaranteed level of telegram recognition. KNX Powerline PL 110 Powerline_E0307d 4/17
5 In addition, a further innovative technique is used, namely the permanent and automatic adaptation of transmission power and receiving sensitivity. This process allows continuous adaptation of the transmission power to the network characteristics, thereby taking into account that the maximum transmission level is never exceeded. All receivers likewise permanently adapt their sensitivity according to the network characteristics. This results in an optimum transmission range even under constantly changing supply conditions. U L1 L2 L3 t 6.67 ms 8 bit periods 20 ms 24 bit periods Figure 2: Phase coupling 3.1 Phase Coupling In order to ensure that data is transmitted on all three conductors, the following two possibilities exist: In smaller installations, a passive phase coupling across the connections to devices with more than one phase (e.g. gas heater, electric cooker) can suffice. However, in order to ensure a defined coupling between the three external conductors, the use of a phase coupler is recommended. In larger installations, the integration of a system coupler in the repeater function 1 is recommended. The system coupler has 4 poles (3 external conductors and 1 neutral conductor) and couples signals with the highest possible transmission level on each external conductor. 1 The repeater has meanwhile been integrated in the system coupler and is no longer available as an individual device. See also the chapter System Devices: System Coupler. KNX Powerline PL 110 Powerline_E0307d 5/17
6 Phase couplers and system couplers may not be installed simultaneously in an installation. This means that if a repeater is retrofitted in an installation with an integrated phase coupler, the phase coupler must be removed. Training sequence Preamble field Telegram as for KNX-TP1 System ID 4 bits 2 x 8 bits Variable length 8 bits Figure 3: Telegram transmission Additional 4 bits per 8 bits for error correction 3.2 Telegram Transmission Compared to the KNX-TP1 telegram, KNX PL 110 requires additional information during the transmission of data Training Sequence The training sequence acts as the automatic reception adjustment of the receivers (thus of all mains couplers except those that are transmitting). The receivers adjust their reception to the network conditions Preamble field The preamble field has two functions: It marks the start of the transmission. It controls the bus access Telegram After this the actual telegram is transmitted (as on KNX-TP1), in which four additional bits of test data are added to every transmitted byte. With the help of this test data, one bit errors can be corrected and multi-bit errors can be detected System ID Each telegram is terminated by a field which contains the System ID. The System ID consists of 8 bits (with an additional 4 bits of test data) and can be set by the project engineer of the installation between 1 and 254. The System ID is reserved for information to all devices. The objective of the System ID is to prevent KNX PL 110 installations that are positioned in close proximity from influencing each other. For this purpose, a distinct System ID is attributed to each KNX PL 110 installation. As the System ID is transmitted in the telegram, each receiver can establish whether the telegram belongs to its installation and then react accordingly. KNX Powerline PL 110 Powerline_E0307d 6/17
7 Training sequence Preamble field Reply telegram 4 bits 2 x 8 bits 8 bits + 4 bits for error correction Figure 4: Reply telegram Reply Telegram The reply telegram is produced as a result of the received telegram and must reach the transmitter after a certain period of time. Compared to KNX-TP 1, only two reply telegrams are transmitted: ACK: Transmission was successful. NACK: Transmission was not successful. This reply telegram is only used by the system coupler. If the reply telegram is not sent, the telegram is repeated. The further process is dependent on whether the system contains a system coupler or not. The reply telegram may not be sent by all addressed devices but only by one actuator per group address. For this purpose, one group object must be configured as the group speaker during the planning stage. KNX Powerline PL 110 Powerline_E0307d 7/17
8 /400 V distribution board with band-stop filter and phase coupler 5/7/ /7/33 Group speaker flag set 5/7/33 5/7/33 Figure 5: Installations without system coupler 3.3 Installations without System Coupler In the example above, the device is a KNX PL 110 sensor while all the other devices are KNX PL 110 actuators. The sensor is activated. The following occurs: The sensor transmits a telegram with group address 5/7/33. All actuators receive and analyse it. Only the actuator transmits the ACK reply telegram because the project engineer has set the group speaker flag at the corresponding group object for the group address 5/7/33. The following applies: Only one ACK flag may be set per group address (for a group object which is linked to this address). The group speaker flag shall be set at the actuator which is furthest away. If the telegram of is either not received or received incorrectly e.g. due to a mains disruption, the actuator will not send a reply telegram. The sensor repeats the telegram once. KNX Powerline PL 110 Powerline_E0307d 8/17
9 /400 V distribution board with band-stop filter and system coupler 5/7/ /7/33 Group speaker flag set 5/7/33 5/7/33 Figure 6: Installations with system coupler 3.4 Installations with System Coupler The example is identical to the one described in section 3.3 but a system coupler has now been installed in the distribution board. The presence of the system coupler is reported to all the devices during programming. If a system coupler is retrofitted in the installation, all the devices must be reprogrammed. It is not necessary to press the programming button again because the individual address is retained and only the application or base conflict byte, which contains information about a possible system coupler in the installation, is overwritten. The sensor is activated. If the device receives the telegram correctly, it sends an ACK telegram. The process is completed and the system coupler does not come into play. However, if the device does not receive the telegram or receives it incorrectly, the following occurs: The system coupler registers that the ACK telegram has not been transmitted and repeats the telegram. The device now receives the telegram and transmits an ACK. The process is thus completed. If still does not receive the telegram (no ACK from 1.1.5), the system coupler sends a NACK. The sensor receives the NACK and the process is completed. KNX Powerline PL 110 Powerline_E0307d 9/17
10 The following applies: There may only be one group speaker for each group address. The setting is carried out via the ACK flag for one of the group objects that is linked with the group address. The group speaker flag shall be set at the actuator which is furthest away. If a repeater is retrofitted, the following must be carried out: Integrate the repeater in the ETS project: The new repeater status is automatically set for all the PL 110 devices in the project. Download repeater status: All the devices must be informed about the new repeater status by downloading the application software. Only once the download is concluded are all the devices aware that a system coupler with repeater function has been integrated into the installation. The mains couplers are now aware of the existence of a system coupler in the installation. A transmitting mains coupler will now no longer repeat the telegram, should the reply telegram not be sent. The system coupler must be installed in a central point of the installation (in the distribution board). Only one system coupler per installation is permitted. If a larger KNX/EIB installation is implemented, in which there are several KNX Powerline areas, a system coupler with its own System ID must be installed in each KNX Powerline area. 3.5 Bus Access Procedure As in KNX-TP1, a bus access procedure is also necessary for KNX PL 110 in order to prevent collisions. Owing to the high level of background noise on the 230/400 V supply system, bus access cannot be related to the voltage level. The collision problem has been resolved by the use of special time slots i.e. every mains coupler may only transmit during specified periods. However, if several mains couplers try to start transmission simultaneously, the following applies: The mains couplers detect a collision and determine a new random priority for the transmission of telegrams. KNX Powerline PL 110 Powerline_E0307d 10/17
11 Figure 7: Topology / Addressing 4 Topology / Addressing The logical addressing of KNX-PL 110 is compatible with KNX-TP1. A maximum of 8 areas (compared to 15 for KNX-TP1) can be addressed, each with 16 lines of 256 devices. Areas containing PL signals must be separated from the general supply system via bandstop filters. The band-stop filters are however no longer required uniformly by all suppliers. If in doubt, you should check the local Technical Connection Requirements. The system coupler forms the interface to KNX-TP1 in combined installations. In a detached house it is not strictly necessary to split up the devices into lines and areas via corresponding couplers, provided that the number of PL 110 devices does not exceed 256. All PL 110 devices can exchange data across all 3 external conductors via the 230 V installation network, once a phase coupler or system coupler has been installed. KNX Powerline PL 110 Powerline_E0307d 11/17
12 Figure 8: Topology / Addressing Note: The 24 V supply of the TP main line can be taken from a system coupler. In larger installations, the bus load is reduced via a logical and physical classification of the KNX-PL 110 installation into a maximum of 8 areas with up to 15 lines (with up to 255 PL 110 devices per area). The physical separation of the individual areas is achieved using band-stop filters. Data can be transmitted from one line to another via the known KNX-TP1 main line between the system couplers. The area coupling is likewise established as a KNX-TP1 main line between the system couplers. The active phase coupling on the PL 110 side is carried out by the system coupler. The physical separation and the filter table of the system coupler allow a selective transmission of telegrams into the neighbouring area. The bus load in the entire system is thus considerably reduced. KNX Powerline PL 110 Powerline_E0307d 12/17
13 5 KNX PL 110 System Devices Mains Coupler There are four types of mains couplers: flush-mounted design for installation in standard flush-mounted wall boxes surface-mounted design for installation in surface-mounted housing DIN rail design for mounting on standard DIN rail adapter Each mains coupler has its own integrated power supply unit. The power consumption on the d.c. side is: In receiving state: 5 V/30 ma and 24 V/1 ma => 174 mw In transmitting state: 5 V/30 ma and 24 V/ ma => 390 mw W, depending on mains impedance Leakage loss: 0.5 to 1.5 W Mains Coupler and Compact Devices in Flush-mounted Design Characteristics of this mains coupler: It can be built into a wall box but the box must have screws to secure the mains coupler onto the retaining ring. It has a standard 10-pole physical external interface (PEI) which is fitted according to SELV specifications. The mains connection is carried out by two screw terminals, whereby a conductor cross section of 2.5 mm 2 can be connected. The mains supply terminals are marked L and N. Characteristics of compact devices: Compact devices are mains couplers with integrated actuators e.g. switch, dimming or shutter actuator Surface-mounted Design Characteristics of this mains coupler: It can be inserted in flush-mounted or surface-mounted housing It has a standard 12-pole PEI which is however not isolated from the 230/400V supply. If necessary, the device developer must carry out this separation. The mains connection for the device developer is achieved by a 2-pole connection post on the printed circuit-board. The mains connection for the installer is manufacturer-specific. 2 PL devices do not require a PE connection. A corresponding terminal connection is necessary for looping through the PE conductor (as in a conventional switch). KNX Powerline PL 110 Powerline_E0307d 13/17
14 5.1.3 DIN Rail Mounted Design Characteristics of this mains coupler: It can be mounted on standard DIN rails. It has a width of 1.5 modules. It has a standard 12-pole PEI which is fitted according to SELV specifications. The mains connection is achieved by four screw terminals (two terminals each for L and N), whereby a conductor cross section of 2.5 mm 2 can be connected. The mains supply terminals are marked L and N Adapter Characteristics of this mains coupler: It is inserted in the Schuko socket. It is available as a switch and universal dimming actuator. 5.2 Phase Coupler Design: DIN rail, 1 module wide Three-phase connector without neutral conductor Passive capacitive coupling Used in small installations without a system coupler Fused with a circuit-breaker 5.3 System Coupler Design: DIN rail mounted, 4 modules wide Three-phase connector + neutral conductor Ensures active phase coupling and telegram repetition Only one system coupler permitted per installation All mains couplers must be informed about the integration of a system coupler into an installation It can also be used as a media or backbone coupler Media Coupler: Used for coupling KNX-TP1 and KNX-PL110 installations Full repeater functionality on PL110 side Used in the project in the same way as a line coupler KNX-TP1 side is primary, PL 110 side is secondary Dynamically organised buffer for up to 256 telegrams The following parameters are available: Telegram routing similar to the line coupler. The parameters for blocking, routing and filtering can be set for both directions. Telegram acknowledgement for routed telegrams on KNX-TP1 side. Repetitions in the event of transmission errors on KNX-TP1 side KNX Powerline PL 110 Powerline_E0307d 14/17
15 Backbone Coupler: Used for coupling PL areas and for configuring a structured topology in larger installations Full repeater functionality in PL area to which it is assigned Data cable of backbone coupler must be supplied internally with 24 V The same parameters are available as for the media coupler Repetitions in the event of transmission errors on the data cable of the backbone coupler. 5.4 Band-stop Filter Design: DIN rail mounted, 2.5 modules wide, single-phase connection + neutral conductor Max. load: 63 A with an operating temperature up to 25 C Connection of the external conductor: via screw terminals up to 25 mm 2 Connection of the neutral conductor: via screw terminal up to 2.5 mm 2 In installations with a nominal current between 63 A and 125 A and a conductor cross section exceeding 25 mm 2, it is permitted to install two band-stop filters per phase in parallel using main branching terminals. Each band-stop filter must be secured according to its nominal load. As the effectiveness of the band-stop filter is dependent on direction, the current flow direction must be observed in the direction of the printed arrows during installation (connection below: supply cable, connection above: KNX PL 110 installation). The supply cable to the band-stop filter and the cable leading from it should be placed as far apart as possible (recommended minimum interval: 10 cm) in order to prevent unwanted signal interference. Attenuation: 40 db Used to weaken signals: to separate various installations in a building for example to filter out interference It must always be installed to meet existing regulations or any regulations in development (e.g. technical connection conditions of the electricity board). A band-stop filter must be installed per external conductor. Installation site: normally in the distribution board directly behind the main fuse or the fault current switch. A band-stop filter can be omitted if the installation has its own transformer area. KNX Powerline PL 110 Powerline_E0307d 15/17
16 5.5 Mains Cables All standard 230/400 V cables can be used. However, shielded cables where the shield has been earthed should not be used due to signal attenuation. 6 Information for Planners, Project Designers and Installers The integration of PL 110 installations can be carried out without any limitations in the residential sector. PL 110 installations should however be enclosed signal areas e.g.: installations behind the electricity meter e.g. in detached houses or multiple dwellings separate supply systems in larger buildings e.g. lighting or shutter control installations in administration buildings KNX PL 110 does not function or cannot be used: Across a transformer substation In networks with deviating parameters (e.g. 110 V/60 Hz) In networks in which other carrier-frequent systems have already been installed for supply data transmission in the frequency band 95 khz 125 khz. In networks with insufficient noise suppression (according to regulations). Problems are caused by mains parallel capacitors, inverters, UPS installations and insufficiently suppressed industrial machines (cranes, welding machines, eroding machines etc.). In these cases, separate cables or band-stop filters are used to isolate the devices causing interference. For signal transmission between houses and buildings due to regulations. For safety-related applications e.g. installations for monitoring sustaining and lifesaving functions as well as for functions whose failure can lead to extensive damage. A prerequisite for the operation of PL 110 is the effective interference suppression of all the electrical loads used in the installation. This can nowadays be assumed due to the legal regulations and norms for these devices. When a variety of electromotive and frequency-controlled loads are used, this factor should be checked (CE mark of the devices). Practical experience shows that the interference caused by electronic ballasts and electronic transformers is largely dependent on whether these devices are installed correctly. The appropriate requirements should be obtained from the operating instructions of the manufacturers. Installation functions and customer requirements should be established as for KNX- TP1. The system coupler should be installed in the central point of the installation to achieve the highest possible ranges. Transmission speed: 1200 bit/s => approx. 6 telegrams per second can be transmitted. KNX Powerline PL 110 Powerline_E0307d 16/17
17 Bus devices should not be commissioned in such a way that they transmit cyclical telegrams in short intervals (shorter than a minute). Do not use any unshielded 230/400 V cables (with shield potential to ground). Cable routing: as required (but in the case of band-stop filters, incoming and outgoing cables should not be laid in parallel). If there are several installations in one building, avoid running cables in parallel in order to avoid cross-talk between installations. Circuit-breakers and protective switches with a nominal current smaller than 10 A shown a high level of signal attenuation. These devices should therefore not be installed between two transmitting devices. If necessary, cut-out fuses should be used in this case. Always use one band-stop filter per external conductor (exception: own transformer area), even when the transmission is limited to one phase. Pay attention to the heat dependency of the load capacity of the band-stop filter. If necessary, divide electrical circuits across several band-stop filters. Overvoltage protection: The regulations for 230/400 V installations apply. A PL 110 installation is commissioned in the same way as for KNX-TP1. If a system coupler is retrofitted in an installation as a repeater (or removed), it also has to be reconfigured (removed) in ETS. All bus devices then need to be reprogrammed accordingly so that they know that the installation has a new repeater status. A bus reset in a PL 110 installation can only be achieved by triggering the appropriate circuit-breaker. When using KNX-PL 110 in installations with devices known for causing interference (e.g. inverters, UPS installations), the separation of the load and signal circuit can already be taken into account at the planning stage. KNX Powerline PL 110 Powerline_E0307d 17/17
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
ABB i-bus EIB Logic Module LM/S 1.1
Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...
ABB i-bus KNX Fan Coil Controller FC/S 1.1
Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Light scene push button 8gang comfort flush-mounted 751688xx
751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional
Inwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2
Product Manual ABB i-bus EIB US/U 4.2 US/U 2.2 Intelligent Installation Systems Intelligent and limitless Contents Page 1 General............................................. 3 1.1 Product and functional
ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1
Product Manual ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Intelligent Installation Systems This manual describes the function of the EIB monitoring module EUB/S 1.1 with the Application program
Transmitter Actuator 230V wave UP 560. Operation
Transmitter ctuator 230V wave UP 560 5WG3 560-201 Product- and pplication Description Diagram The transmitter actuator 230V wave UP 560 (Diagram ) is a flush-mounted device with radio communication for
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1
Product manual ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
Application Unit, MDRC AB/S 1.1, GH Q631 0030 R0111
, GH Q631 0030 R0111 SK 0010 B 98 The application unit is a DIN rail mounted device for insertion in the distribution board. The connection to the EIB is established via a bus connecting terminal at the
KNX Gateway RGK02-5023E-01
KNX Gateway RGK02-5023E-01 Table of contents Page 1 General Information 1.1 Technical data 5 1.2. Intended Use 6 1.3 Specifications 6 1.4 Compatibility 6 1.5 Scope of delivery 6 2 Information about the
KNX System Principles
Application Module Bus Transceiver KNX b a T1 C1 T2 Left II Left On Left II Right Off Left X Left Off Left X Right On Left II Left On Left II Right Off Left X Left Off Left X Right On c b a c E2 Bus Cable
Busch-Watchdog Presence EIB Type: 6131-74-102-500
Type: 6131-74-102-500 Contents Technical data 2-2 Application programs (List) 2-3 Circuit diagrams 2-3 in combination with Bus coupler FM (6120-102): Switch Value Cyclic Monitoring /3 2-4 Switch Value
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
Push button 3gang standard flush-mounted 751633xx
Documentation Product name: Push button 3gang standard Design: device (up) ETS search path: Push button / Push button 3gang / Push button 3gang standard Functional description: The push button 3gang standard
Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX Data Logging Unit BDB/S 1.1 Intelligent Installation Systems ABB This manual describes the function of the Data Logging Unit BDB/S 1.1. Subject to changes and errors excepted.
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
Actuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
Building Service Management System instabus EIB
Training & Didactic Systems Building Service Management System instabus EIB Catalog WA2E/07.01 Catalog WA2E/07.01 Table of Contents Page Introduction to instabus EIB 4 Configuration Proposals for instabus
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx
756627xx, 756637xx, 756657xx Documentation Product name: Push button 2-, 3-, 5- gang RTR + display Design: UP (flush-mounting type) ETS search path: Push button / Push button xgang / Push button xgang
B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x
B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
ABB i-bus KNX SA/S Switch Actuators Product Manual
ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional
ABB i-bus EIB / KNX Weather Station WS/S 4.1
Product Manual ABB i-bus EIB / KNX Weather Station WS/S 4.1 Intelligent Installation Systems This manual describes the function of the Weather station WS/S 4.1. Subject to changes and errors excepted.
Allen-Bradley/Rockwell
MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:
Power supply 142. Couplers 143. Data interfaces 144. Accessories 145
KNX system units The system components are KNX devices, which assume higher-level functions, independent of the application. They guarantee the necessary infrastructure in the building, ensuring a flawless
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
IntesisBox KNX Modbus RTU master
IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control
ABB i-bus KNX DALI-Gateway DG/S 8.1
Product manual ABB i-bus KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes Dynamic
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
Documentation. M-Bus 130-mbx
Documentation M-Bus 130-mbx Introduction The mx M-Bus module is part of the mx Smart Slot communications family. With the integrated SmartSlot technology, mx systems ag offers automatic consumer data read-out
KNX Panasonic Air Conditioners
IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S 2.300.2. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX Universal Dim Actuator, MDRC UD/S 2.300.2 Intelligent Installation Systems ABB UD/S 2.300.2 Universal Dim Actuator, MDRC This manual describes the function of the Universal
Adding Heart to Your Technology
RMCM-01 Heart Rate Receiver Component Product code #: 39025074 KEY FEATURES High Filtering Unit Designed to work well on constant noise fields SMD component: To be installed as a standard component to
Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager
Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager Introduction There is a growing trend in the UPS industry to create a highly efficient, more lightweight and smaller UPS
Single Channel Loop Detector
Single Channel Loop Detector Model - LD100 Series The LD100 is a single channel inductive loop detector designed for parking and access control applications. The detector is connected to an inductive loop
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Inwall Room Temperature Unit
Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall
Application Note. Troubleshooting Communications
ANX Application Note Troubleshooting Communications This document is a guide for basic troubleshooting of UPB communication issues. There are two things that can disturb UPB communications: noise and attenuation.
OZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
Cable Solutions for Servo and Variable Frequency Drives (VFD)
Cable Solutions for Servo and Variable Frequency Drives (VFD) Electric drive systems with continuous torque and speed control are widespread today. They allow an optimal adjustment of the drive with respect
ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011
, 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially
LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 [email protected]
Integrations LGAC-KNX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 [email protected] www.ingeniumsl.com
KNX Interface. User Manual PM00A00IRI
KNX Interface User Manual PM00A00IRI 1/9 1. Index 1. Index...2 2. Preface... 3 2.1. Overview... 3 2.2. System description... 3 2.3. Application programs... 3 2.4. Documentation... 3 3. Mechanical reference...
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
EIB/KNX IP Interface with Power over Ethernet (PoE)
EIB/KNX IP Interface with Power over Ethernet (PoE) IP Interface between LAN and EIB/KNX bus (Quelle: EIBMARKT GmbH, Reference No.: N000401) Page 1 Application area The KNXnet/IP-Interface is used to connect
Insulation resistance
The insulation resistance is particularly important for the prevention of damage and injury, and for the reliability of electrical systems and equipment. On the one hand it is basis for the protection
SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
ABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
Technical Description. Transistor D.C. Chopper Controller Type GS 24 S
Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
Multi-Protocol decoder 76 200 with Load regulation
Multi-Protocol decoder 76 2 with Load regulation For locomotives with universal motors on digital layouts operating in the DCC and Motorola data format. Features 76 2 Load regulated multi-protocol decoder
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
IntesisBox KNX - LON
IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,
KNX. Siemens Building Technologies HVAC Products. Synco Konnex bus. For devices of the Synco 700 / RXB ranges
7 7Z0 Synco Konnex bus For devices of the Synco 700 / RXB ranges KNX The Konnex bus (short KNX) unites the three existing bus technologies EIB (European Installation Bus also called Instabus), BatiBUS,
1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions
Compact presence detector Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
RS485 & RS422 Basics
RUA ALVARO CHAVES, 155 PORTO ALEGRE RS BRASIL 90220-040 TEL: +55 (51) 3323 3600 FAX: +55 (51) 3323 3644 [email protected] RS485 & RS422 Basics INTRODUCTION The 422 and 485 standards, as they are known
ABB i-bus KNX Switch Actuators SA/S Product Information
ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011
Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications June 2011 Application Note Common mode chokes provide an effective EMI filtering solution for Ethernet transformer applications.
DMX2PWM 9 Channel Dimmer Setup Manual
DMX2PWM 9 Channel Dimmer Setup Manual www.ecue.de DMX2PWM 9ch Dimmer - Setup Manual e:cue control GmbH An OSRAM Company Rev. 1.3_01/2010 DMX2PWM 9ch Dimmer - Setup Manual Table of Contents 1. Device Overview....................................4
Highly flexible the right KNX/DALI gateway for every requirement
The worldwide standard for home and building control Highly flexible the right / gateway for every requirement Integrating lighting control into building control safely, efficiently and comfortably with
SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE WELDERS
SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE S By Jack Farrow, May, 2004 WELDING TECHNOLOGY CORPORATION ABSTRACT Information on how to select the correct size of substation transformer and 480V bus to
INDEPENDENT HOBS WITH HIC ELECTRONIC CONTROL
INDEPENDENT HOBS WITH HIC ELECTRONIC CONTROL ESSE-N / A.S. 1 What is HIC? HIC = Hob Independent Control New touch-control electronic for independent hobs, with new user interface philosophy Electronic
FN2001-A1 Network module (SAFEDLINK) Mounting Installation
FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without
Installation guide H-5500-8554-03-A. HSI hardwired system interface
Installation guide H-5500-8554-03-A HSI hardwired system interface 2008-2011 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any
EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH
ENGLISH EMOSAFE EN-100 Product Data Sheet Network Isolators for PCB assembly November 2013 1 GENERAL DESCRIPTION The EMOSAFE EN-100 Network Isolator interrupts all galvanically conducting connections (conductors
Vibration Monitoring System Adash 3600
" User's guide Application: Vibration Monitoring System Adash 3600! Vibration diagnostics, monitoring and protective on-line system! On-line vibration monitoring system of engines, fans, pumps, gearboxes,
PLC-INVENTIONS FOR LARGER UTILIZATION (PLC= Power Line Communication. 9 khz 30 MHz )
PLC-INVENTIONS FOR LARGER UTILIZATION (PLC= Power Line Communication. 9 khz 30 MHz ) (Inventions 1, 2 and 3= Patents 1, 2 and 3) Possible applications: Home and house automation, i.e. intelligent homes
KNX R. Rain Sensor. Installation and Adjustment
EN KNX R Rain Sensor Installation and Adjustment 1 Content 1. Description... 3 1.1. Technical specifications... 3 2. Installation and commissioning... 4 2.1. Installation notes... 4 2.2. Location... 4
Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
DALIX PROGRAMMING MANUAL. Gateway KNX-DALI V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 [email protected]
Gateway KNX-DALI DALIX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 [email protected] www.ingeniumsl.com
Glass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat
KNX/EIB Product documentation Glass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat Issue: 16.01.2009 65750120 Page 1 of 240 KNX/EIB Product documentation Content 1 Product definition...
ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011
Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are
What ensures easy and fast wiring?
What ensures easy and fast wiring? SIMATIC TOP connect: the system cabling for connecting sensors and actuators to SIMATIC S7. Answers for industry. More efficient cabling made easy: SIMATIC TOP connect
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
Technical Article. EMC filters for medical devices
Technical Article EMC filters for medical devices September 2010 EMC filters for medical devices Schaffner, the market leader in EMC filters and power quality, has supplemented its proven IEC inlet filter
ABB i-bus KNX IP Router IPR/S 2.1
Product Manual ABB i-bus KNX IP Router IPR/S 2.1 Intelligent Installation Systems This manual describes the function of the IP Router IPR/S 2.1 with the application program IP Routing. Subject to changes
ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB. www.elabo-ts.com
Aus- und Weiterbildung GmbH Home and Building Control KNX / EIB www.elabo-ts.com Design and commissioning of KNX/EIB systems www.elabo-ts.com Hardware page 2-5 Software page 6-9 Projects page 10-15 LOGO!
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential
Road Vehicles - Diagnostic Systems
SSF 14230 Road Vehicles - Diagnostic Systems Keyword Protocol 2000 - Part 1 - Physical Layer Swedish Implementation Standard Document: SSF 14230-1 Status: Issue 3 Date: October 22, 1997 This document is
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control
Wireless Control Systems Accessories Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Accessories Programming Switching & Dimmer Functions
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
