mecotron Safety relay ESTOP-2 For emergency stop monitoring
|
|
- Sherilyn Potter
- 4 years ago
- Views:
Transcription
1 E Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated in emergency stop or safety circuits in accordance with relevant standard EN These modules meet the requirements of European standards EB-EN 418 for emergency stops and EN for safety circuits. These standards cover cases where a single emergency stop device must break several circuits (indirect action emergency stop). Emergency Stop monitoring 2 safety output circuits 2 LED displays 3 supply voltage versions Safety category 3 Conforming to standards Product : EN category 3 Machine : EU-machine-guidelines 89/392 EWG Approvals : Accessories 24 V AC/DC V AC (50/60 Hz) V AC (50/ 60 Hz) Power consumption A1-A2 24 V AC/DC - < 3 VA / W A1-A2 115 V AC - < 3 VA A1-A2 230 V AC - < 3 VA tolerance 24 V AC/DC -10 % % 115 V AC -15 % % 230 V AC -15 % % Rated frequency AC variance 115 V AC Hz 230 V AC Hz Stop monitoring circuit single-channel or dual-channel Voltage potential Current over the command device approx. 60 ma - Relay / contactors, force guided Voltage potential in feedback loop 24 V DC Display of operating status (LED) Output relay energized Output circuit / Safety exits 13-, Relay, 2 NO contacts, force guided, internal monitored Rated operational voltage 300 V Rated operational current AC (resistive) 2.5 A (at 240 V) Rated operational current AC 15 (inductive) 0.75 A (at 240 V) Rated operational current DC (resistive) 2.5 A (at 24 V) Rated operational current DC 13 (inductive) 1.25 A (at 24 V) Mechanical life (max.) 10 x 10 6 operations Electrical life (max.) (on AC / 240 V / 2.5 A) 6 x 10 5 operations Short-circuit protection, max. fuse rating 4 A / fast, type gl Impulse withstand voltage Vimp -20 C C -25 C C Mounting to DIN rail (EN 500) snap-on fastening/screw mounting using adapter Terminal capacity 2 x AWG (2 x 2.5 mm 2 ) Weight approx lb (200 g) Dimensions (W x H x D).5 x 78 x 0 mm Adapter for screw mounting Supply Start button Emergency voltage activated deactivated not operated Stop activated "A1" "A2" Start button External start conditions (ESC) Output 13- (NO) Wiring diagrams button with 2 NC contacts button with 1 NC contact 1743
2 E Safety relay E-3 For emergency stop monitoring Operation The E-3 module provides a safety oriented interruption of safety circuits. It can be integrated in emergency-stop or safety circuits in accordance with EN This module corresponds to the European standards EN 418 for emergency-stop equipment and EN (safety circuits). These standard cover cases where a single command must open several circuits (emergency stop by indirect action). E-3 offers 3 outputs with immediate opening contacts for safety circuits of stop category 0 as well as an auxiliary NC contact. Wiring examples Emergency-stop button with two NC contacts / 2 channels Emergency-stop button with one NC contact / 1 channel Emergency-stop monitoring 3 Safety output circuits 2 LED function displays Safety category 3 Conforming to the standards Product: EN category 3 Machine: EU-machine guidelines 89/392 EWG Approvals: ESC = External starting conditions Ref. no.: 24 V AC/DC Accessories Ref. no.: Adapter for screw mounting power consumption A1-A2 24 V AC/ DC VA/ 3.5 W Tolerance of supply voltage 24 V AC/DC 24 V AC - -20% % 24 V DC - -20% % Rated frequency AC variances 115 V AC 230 V AC Emergency-stop circuits single-channel or dual-channel Voltage potential Current via indication device approx. 200 ma Cross-circuit protection Relay/ contactor, force guided Voltage potential in feedback loop 24 V DC Display of operational status LED green Output relay energized LED green Output circuit 13-, 23-24, 33-34,41-42 Relay, volt-free, force guided, internal monitored Safety outputs/ auxiliary circuit 3 NO contact / 1 NC contact Rated operational voltage 300 V max. / 300 V max. Rated operational current AC (resistive) 5 A (at 230 V) / 2 A (at 230 V) Rated operational current AC 15 (inductive) 1.5 A (at 230 V) / 2 A (at 230 V) Rated operational current DC (resistive) 5 A (at 24 V) / 2 A (at 24 V) Rated operational current DC 13 (inductive) 1.25 A (at 24 V) (L/R=100 ms) 2 A ( at 24 V) Mechanical life max. 10 x 10 6 operations Electrical life max. (acc. to AC / 240 V / 5 A) 3 x 10 5 operations Short-circuit proof, max. fuse rating 4 A, operating class gl Limit of accum. currents at simultaneous load on several output circuits Sum current I th < 10 A Impulse voltage withstand Vimp Response time of the output relays < 40 ms -10 C C -25 C C Mounting on DIN rail (EN 500) Snap-on mounting/screw mounting by adapter Wire size stranded with wire end ferrule AWG (2.5 mm 2 ) Weight approx lb (300 g) Dimensions (W x H x D).5 x 78 x 0 mm Supply Start button Emerg. stop Emerg. stop not pressed pressed inactive active Emerg. stop "A1" Emerg. stop "A2" Feedback loop Output 13 - (n/o) Output (n/o) Output (n/c) Output (n/c) 1744
3 E Safety relays E-2a and E-2b provides a safety interruption of one or several circuits Emergency Stop monitoring and monitoring of protective guards Start button monitoring / configurable 2 safety outputs 2 auxiliary transistor-outputs Monitoring of safety-mats (E-2b) 4 LED displays 3 supply voltage versions E-2a 24 V AC/DC V AC (50/60 Hz) V AC (50 Hz) Description The E-2a (E-2b) module provides a safety oriented interruption of one or several circuits and is designed to be integrated in emergency stop or safety circuits conforming to EN It meets the requirements of the European standard EN 418 for emergency stop equipment and EN for safety circuits. These standards concern the applications where a single command must open several circuits (emergency stop by indirect action). The module also meets the safety requirements for electrical monitoring of limit switches on protective equipment. Conforming to standards Product : EN category 4 Machine : EU-machine-guidelines 89/392 EWG Approvals : E-2b 24 V AC/DC V AC (50/60 Hz) V AC (50/60 Hz) power consumption A1-A2 24 V AC/DC - < 7 VA / W A1-A2 115 V AC - < 10 VA A1-A2 230 V AC - < 10 VA tolerance 24 V AC/DC -20 % % 115 V AC -15 % % 230 V AC -15 % % Rated frequency AC variance 115 V AC Hz 230 V AC Hz Stop monitoring circuit S11-S, S-S, B1 single-channel or dual-channel Voltage potential VS11/S 24 V AC/DC VA1-A2-3 V 115 V AC > 42 V 230 V AC > 42 V Synchronous time between Input A and Input B approx. 300 ms through internal electronic fuse Max. line resistance RL 50 Ω Other Inputs Connection of an external start button S33-S34 volt-free Start button monitoring configurable (E-2b) Y3-Y4 open-monitoring/linked-no monitoring Connection of short circuit making sensor mats, S31-S32 volt-free safety mats or other volt-free contacts (E-2b) S41-S42 Max. resistance between S31-S32, S41-S42 50 Ω Relay / contactors, force guided Voltage potential in feedback loop 24 V DC Display of operating status (LED) /internal electronic fuse Input A (S11-S) Input B (S-S) Output relay energized Output circuit, safety outputs 13-, Relay, 2 NO contacts, volt-free, force guided, internal monitored Rated operational voltage 300 V Rated operational current AC (resistive) 2.5 A (at 240 V) Rated operational current AC 15 (inductive) 0.75 A (at 240 V) Rated operational current DC (resistive) 2.5 A (at 24 V) Rated operational current DC 13 (inductive) 1.2 A (at 24 V) L/R = 50 ms Short circuit protection, max. fuse rating 4 A type gl Response time of the output relays < 40 ms Output circuit, auxiliary circuit 2 transistor-outputs, NO contact function Transistor-output (E-2b) Y33-Y34 typ. 24 V/20 ma, status of the internal electronic fuse Transistor-output (E-2b) Y43-Y44 typ. 24 V/20 ma, status of the output relays, Impulse withstand voltage Vimp Mechanical life (max.) 10 x 10 6 operations Electrical life (max.) (on AC / 240 V / 2.5 A) 6 x 10 5 operations -10 C C -25 C C Mounting to DIN rail (EN 500) snap-on fastening/screw mounting using adapter Terminal capacity 2 x AWG (2 x 2.5 mm 2 ) Weight 24 V AC/DC / 115 V AC and 230 V AC approx lb (350 g) / approx lb (450 g) Dimensions (W x H x D) 45 x 78 x 0 mm E-2a : The module is equipped with two voltage free safety outputs of stop category 0 (EN 418, EN 60204). E-2b : In addition to the two voltage free safety outputs of stop category 0 (EN 418, EN ), the module is equipped with two semiconductor outputs for signalling functions. Additionally it is possible to monitor sensor mats with the E-2b. The module is designed for use with one or two input channels. For extended fault detection and increased safety level, we recommend the use of two input channels. In this operation mode, the connection cables are integrated in the monitoring and all initial faults will be detected. Start Emergency not stop Input A (S11-S) Input B (S-S) Output 13- (NO) Start Emergency not stop Input A (S11-S) Input B (S-S) Sensor (S31-S32) Sensor (S41-S42) Output 13- (NO) Fuse ok Y33-Y34 / Y43-Y44 1 With start button monitoring, Y3-Y4 open 2 Without start button monitoring, Y3-Y4 shorted out Accessories Adapter for screw mounting
4 A B E Safety relays E-2a and E-2b provide a safety interruption of one or several circuits Wiring diagram E-2a E-2b L (+) -F1 L (+) -F1 ESB EMERGENCY ESB EMERGENCY only at 115V/230V A1 S11 S S S B1 Y1 Y E - 2a T - + LOGIC only at 115V/ 230V A1 S11 S S S S31 S32 B1 Y1 Y Y34 E - 2b T - + A2 PE S33/41 S42 Y3 Y4 LOGIC A1/A2 Fuse / S34 24 Y33/43 Y44 A2 PE S33 S S3 A B Start SENSOR MAT +24V Start N (-) N (-) 2 floating safety outputs Without monitoring of the start button 2 floating safety outputs Wiring diagram One channel connection of the button Protective guard (closed) Open the protective guard A1 S11 B1 S S S 13 - S1 - S2 13 Input A Input B Two channel connection of the button, without short-circuit detection A1 S11 B1 S S S 13 -S1 11 Without start button (automatic start) A1 S11 B1 S S S 13 Two channel connection of the button, with short-circuit detection -S1 11 With start button, without monitoring (switching on at the positive edge) A1 S11 B1 S S S 13 Connection of several emergency stop buttons Start 1 With start button, with monitoring (switching on at the negative edge) -S Y3-Y4 open! -S Start ==> only for E-2b A1 S11 B1 S S S
5 E Safety relays E-3a and E-3b provide a safety interruption of one or several circuits Emergency Stop monitoring and monitoring of protective guards start button monitoring / configurable (E-3b) 3 safety outputs 1 NC auxiliary output 2 auxiliary transistor-outputs Monitoring of safety mats 4 LED displays 3 supply voltage versions E-3a 24 V AC/DC V AC (50/60 Hz) V AC (50 Hz) Description The E-3a (E-3b) module provides a safety oriented interruption of one or several circuits and is designed to be integrated in emergency stop or safety circuits conforming to EN It meets the requirements of the European standard EN 418 for emergency stop equipment and EN for safety circuits. These standards concern the applications where a single command must open several circuits (emergency stop by indirect action). The module also meets the safety requirements for electrical monitoring of limit switches on protective equipment. Conforming to standards Product : EN category 4 Machine : EU-machine-guidelines 89/392 EWG Approvals : E-3b 24 V AC/DC V AC (50/60 Hz) V AC (50/60 Hz) Power consumption A1-A2 24 V AC/DC - < 7 VA / W A1-A2 115 V AC - < 10 VA A1-A2 230 V AC - < 10 VA tolerance 24 V AC/DC -20 % % 115 V AC -15 % % 230 V AC -15 % % Rated frequency AC variance 115 V AC/ 230 V AC Hz Stop monitoring circuit S11-S, S-S, B1 single-channel or dual-channel Voltage potential VS11/S 24 V AC/DC VA1-A2-3 V 115 V AC > 42 V 230 V AC > 42 V Synchronous time between Input A and Input B approx. 300 ms through internal electronic fuse Max. line resistance RL 50 Ω Other inputs Connection of an external start button S33-S34 volt-free Start button monitoring configurable (E-3b) Y3-Y4 open-monitoring/linked-no monitoring Connection of short circuit making sensor mats, S31-S32 volt-free safety mats or other voltfree contacts (E-3b) S41-S42 Max. resistance between S31-S32, S41-S42 50 Ω Relay / contactors, force guided Voltage potential in feedback loop 24 V DC Display of operational status (LED) /internal electronic fuse Input A (S11-S) Input B (S-S) Output relay energized Output circuit 13-, 23-24, 33-34, Relay, volt-free, force guided, internal monitored Safety outputs / auxiliary circuit 3 NO contacts / 1 NC contact Rated operational voltage 300 V / 300 V Rated operational current AC (resistive) 5 A (at 240 V) / 2.5 A (at 240 V) Rated operational current AC 15 (inductive) 1.5 A (at 240 V) / 0.75 A (at 240 V) Rated operational current DC (resistive) 5 A (at 24 V) / 2.5 A (at 24 V) Rated operational current DC 13 (inductive) 1.5 A (at 24 V) L/R= 50 ms 1.2 A (at 24 V) Short-circuit protection, max. fuse rating 6 A type gl / 4 A type gl Other outputs 2 transistor-outputs, NO-function Transistor-output (E-3b) Y33-Y34 typ. 24 V/20 ma, status of the internal electronic fuse Transistor-output (E-3b) Y43-Y44 typ. 24 V/20 ma, status of the output relays, Limit of accum. currents at simultaneous load on several output circuits Σ current Ith < 8 A Impulse withstand voltage Vimp Response time of the output relays < 40 ms Mechanical life (max.) 10 x 10 6 operations Electrical life (max.) (on AC / 240 V / 2.5 A) 6 x 10 5 operations -10 C C -40 C C Mounting to DIN rail (EN 500) snap-on fastening/screw mounting using adapter Terminal capacity 2 x AWG (2 x 2.5 mm 2 ) Weight 24 V AC/DC / 115 V AC and 230 V AC approx lb (350 g) / approx lb (450 g) E-3a :The module is equipped with three voltage free safety outputs of stop category 0 (EN 418, EN ) and one voltage free NC contact. E-3b : In addition to the three voltage free safety outputs of stop category 0 (EN 418, EN ), the module is equipped with a voltage free NC contact and two semiconductor outputs for signalling functions. Additionally it is possible to monitor sensor mats with the E-3b. The module is designed for use with one or two input channels. For extended fault detection, and increased safety level, we recommend the use of two input channels. In this operation mode, the connection cables are integrated in the monitoring and all initial faults will be detected. Input A (S11-S) Input B (S-S) Output 13- (NO) Output (NO) Signalling output (NC) Start Emergency not stop Start Emergency not stop Input A (S11-S) Input B (S-S) Sensor (S31-S32) Sensor (S41-S42) Output 13- (NO) Output (NO) Signalling output (NC) Fuse ok Y53-Y54 / Y63-Y64 1 With start button monitoring, Y3-Y4 open 2 Without start button monitoring, Y3-Y4 shorted out Note: Dimensions (W x H x D), 90 x 78 x 0 mm Accessories 1747
6 E Safety relays E-3a and E-3b provide a safety interruption of one or several circuits Wiring diagram E-3a E-3b -F1 EMERGENCY -S3 SENSOR MAT ESB only at 115V/ 230V A1 S11 S S S S31 S32 S41 S42 B1 Y1 Y2 E - 3b T - + LOGIC A2 PE S33 Y3 Y4 S Y54 A1/A2 / Fuse Y53/ Y64 Without monitoring of the start button +24V Start -H1 x1 EMERGENCY x2 3 floating safety outputs 1 floating signalling output Wiring diagram One channel connection of the button Protective guard (closed) Open the protective guard A1 S11 B1 S S S 13 - S1 - S2 13 Input A Input B Two channel connection of the button, without short circuit detection A1 S11 B1 S S S 13 -S1 11 Without start button (automatic start) A1 S11 B1 S S S 13 Two channel connection of the button, with short circuit detection -S1 11 With start button, without monitoring (switching on at the positive edge) A1 S11 B1 S S S 13 Connection of several emergency stop buttons Start 1 With start button, with monitoring (switching on at the negative edge) -S Y3-Y4 open! -S Start ==> only for E-3b A1 S11 B1 S S S
7 E Safety relays E-6a and E-6b provide a safety interruption of one or several circuits Emergency Stop monitoring and monitoring of protective guards Start button monitoring / configurable (E-6b) 6 safety outputs 1NC contact and 2 auxiliary transistor-outputs Monitoring of safety mats 4 LED displays 3 supply voltage versions E-6a 24 V AC/DC V AC (50/60 Hz) V AC (50 Hz) Description The E-6a (E-6b) module provides a safety oriented interruption of one or several circuits and is designed to be integrated in emergency stop or safety circuits conforming to EN It meets the requirements of the European standard EN 418 for emergency stop equipment and EN for safety circuits. These standards concern the applications where a single command must open several circuits (emergency stop by indirect action). The module also meets the safety requirements for electrical monitoring of limit switches on protective equipment. Conforming to standards Product : EN category 4 Machine : EU-machine-guidelines 89/392 EWG Approvals : E-6b 24 V AC/DC V AC (50/60 Hz) V AC (50/60 Hz) Power consumption A1-A2 24 V AC/DC - < 7 VA / W A1-A2 115 V AC - < 10 VA A1-A2 230 V AC - < 10 VA tolerance 24 V AC/DC -20 % % 115 V AC -15 % % 230 V AC -15 % % Rated frequency AC variance 115 V AC Hz 230 V AC Hz Stop monitoring circuit S11-S, S-S, B1 single-channel or dual-channel Voltage potential VS11/S 24 V AC/DC VA1-A2-3 V 115 V AC > 42 V 230 V AC > 42 V Synchronous time between Input A and Input B approx. 300 ms through internal electronic fuse Max. line resistance RL 50 Ω Other Inputs Connection of an external start button S33-S34 volt-free Start button monitoring configurable (E-6b) Y3-Y4 open-monitoring/linked-no monitoring Connection of short circuit making sensor mats, S31-S32 volt-free safety mats or other volt-free contacts (E-6b) S41-S42 Max. resistance between S31-S32, S41-S42 50 Ω Relay / contactors, force guided Display of operating status (LED) /internal electronic fuse Input A (S11-S) Input B (S-S) Output relay energized Output circuit 13-,..., 63-64, Relay, volt-free, force guided, internal monitored Safety outputs / auxiliary circuit 6 NO contacts / 1 NC contact Rated operational voltage 300 V / 300 V Rated operational current AC (resistive) 5 A (at 240 V) / 2.5 A (at 240 V) Rated operational current AC 15 (inductive) 1.5 A (at 240 V) / 0.75 A (at 240 V) Rated operational current DC (resistive) 5 A (at 24 V) / 2.5 A (at 24 V) Rated operational current DC 13 (inductive) 1.5 A (at 24 V) L/R= 50 ms 1.2 A (at 24 V) Short-circuit protection, max. fuse rating 6 A type gl / 4 A type gl Response time of the output relays < 40 ms Other outputs 2 transistor-outputs, NO-function Transistor-output (E-6b) Y33-Y34 typ. 24 V/20 ma, status of the internal electronic fuse Transistor-output (E-6b) Y43-Y44 typ. 24 V/20 ma, status of the output relays, Limit of accum. currents at simultaneous load on several output circuits Σ current Ith < 8 A Impulse withstand voltage Vimp Mechanical life (max.) 10 x 10 6 operations Electrical life (max.) (on AC / 240 V / 5 A) 6 x 10 5 operations -10 C C -40 C C Mounting on DIN rail (EN 500) snap-on fastening/screw mounting using adapter Terminal capacity 2 x AWG (2 x 2.5 mm 2 ) Weight 24 V AC/DC / 115 V AC and 230 V AC approx lb (600 g) / approx lb (700 g) E-6a : The module is equipped with six voltage free safety outputs of stop category 0 (EN 418, EN ) and one voltage free NC contact. E-6b : In addition to the six voltage free safety outputs of stop category 0 (EN 418, EN ), the module is equipped with a voltage free NC contact and two semiconductor outputs for signalling functions. Additionally it is possible to monitor sensor mats with the E-6b. The module is designed for use with one or two input channels. For extended fault detection and increased safety level, we recommend the use of two input channels. In this operation mode, the connection cables are integrated in the monitoring and all initial faults will be detected. Input A (S11-S) Input B (S-S) Output 13- (NO) Output (NO) Output (NO) Output (NO) Output (NO) Signalling output (NC) Input A (S11-S) Input B (S-S) Sensor (S31-S32) Sensor (S41-S42) Output 13- (NO) Output (NO) Output (NO) Output (NO) Output (NO) Signalling output (NC) Fuse ok Y83-Y84 / Y93-Y94 Start Emergency not stop Start Emergency not stop 1 With start button monitoring, Y3-Y4 open 2 Without start button monitoring, Y3-Y4 shorted out Note: Dimensions (W x H x D), 90 x 78 x 0 mm Accessories 1749
8 +24V E Safety relays E-6a and E-6b provide a safety interruption of one or several circuits Wiring diagram E-6a E-6b -F1 -F1 EMERGENCY Start ESB *) 1 Only at automatic start EMERGENCY Start ESB *) 1 Only at automatic start *) 1 *) 1 only at 115V/ 230V A1 S11 S S S B1 S33 S34 E - 6a T - + LOGIC Y1 Y only at 115V/ 230V A1 S11 S S S B1 S33 S34 Y1 Y Y84 E - 6b T - + LOGIC A1/A2 / Fuse A2 PE A2 PE S31 S32 S41 S42 Y3 Y Y83/93 Y94 -S3 Without monitoring of the start button SENSOR MAT -H1 x1 EMERGENCY x2 -H1 x1 EMERGENCY x2 ESC = External start conditions 6 floating safety outputs 6 floating safety outputs 1 floating signalling output 1 floating signalling output Wiring diagram One channel connection of the button Protective guard (closed) Open the protective guard A1 S11 B1 S S S 13 - S1 - S2 13 Input A Input B Two channel connection of the button, without short circuit detection A1 S11 B1 S S S 13 -S1 11 Without start button (automatic start) A1 S11 B1 S S S 13 Two channel connection of the button, with short circuit detection -S1 11 With start button, without monitoring (switching on at the positive edge) A1 S11 B1 S S S 13 Connection of several emergency stop buttons Start 1 With start button, with monitoring (switching on at the negative edge) -S S Y3-Y4 open! Start ==> only for E-6b A1 S11 B1 S S S
9 E Delay on release Safety relay E-3+2 For emergency stop monitoring Emergency Stop monitoring and monitoring of protective guards Start button monitoring / configurable 3 safety outputs instantaneous opening 2 safety outputs delayed on release Set delay time adjustable between s 1 NC contact as an auxiliary circuit 4 LED displays 3 supply voltage versions Description The safety module E-3+2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated in emergency stop or safety circuits in accordance with relevant standards EN These modules meet the requirements of European standards BS-EN 418 for emergency stops and EN for safety circuits. These standards cover cases where a single emergency stop device must break several circuits (indirect action emergency stop). Module E-3+2 also meets the safety requirements for electrical monitoring of limit switches in safety guards. Conforming to standards Product: EN category 4 Machine: EU-machine-guidelines 89/392 EWG Approvals: 24 V AC/DC V AC (50/60 Hz) V AC (50/60 Hz) In addition to three outputs with instantaneous opening for stop category 0, module E-3+2 has two additional outputs with delayed opening for stop category 1, which allow controlled deceleration of motor components in order to obtain final stopping (for example braking of the motor by variable speed drive). At the end of the preset time delay, the power supply is switched off by opening the time delay output circuits. The time delay on the two output circuits between terminals and is adjustable from 0 to 30 seconds by means of a -position selector switch. Stopping of the machine is achieved by pressing the emergency stop control. One or more emergency stop buttons, as required by the installation, allow the stop instruction to be transmitted to module E-3+2, which in turn controls stopping of several independent safety circuits. Restarting of the machine is possible when the emergency stop button is released. Restarting is achieved by pressing the start button.the function of the start button on module E- 3+2 is determined by the terminal connections. When terminals Y3-Y5 are linked, the start button is included in the monitoring circuit and the safety outputs are activated after the output signal impulse ceases when the start button is released. When terminals Y3-Y4 are linked, the safety outputs are activated immediately after the start button is operated. This configuration allows the safety module to function automatically as soon as the safety guard is closed, provided that the start button is shorted. Maximum fault detection will be achieved when the module is used in conjunction with one (or more) emergency stop(s) with 2 NC contacts. The feedback loop allows autochecking of relay used to increase the number of output contacts and/or to increase the breaking capacity. Any relay used for this purpose must be provided with mechanically linked contacts. Several emergency stop buttons may be connected in series with a single module. - Power consumption A1-A2 24 V AC/DC - < 8 VA / W A1-A2 115 V AC - < 10 VA A1-A2 230 V AC - < 10 VA tolerance 24 V AC/DC -20 % % 115 V AC -15 % % 230 V AC -15 % % Rated frequency AC variance 115 V AC Hz 230 V AC Hz Stop monitoring circuit S11-S, S-S, B1 single-channel or dual channel Voltage potenial VS11/S 24 V AC/DC VA1-A2-3 V 115 V AC > 42 V 230 V AC > 42 V Synchronous time between Input A and Input B approx. 75 ms through internal electronic fuse Max. line resistance RL 50 Ω Other inputs S33, Y3-Y4, S31-S32, S41-S42 Connection of an external start button Y1-S33 volt-free Start button monitoring configurable Y3-Y4/Y3-Y5 linked-no monitoring/linked-monitoring Relay / contactors, force guided Display of operating status (LED) /internal electronic fuse Input A (S11-S) Input B (S-S) State of the time delayed output relays Output circuit 13-, 23-24, 33-34, 57-58, 67-68, Relay, volt-free, force guided, internal monitored Safety outputs 3 NO contacts 2 NO contacts Auxiliary circuits 1 NC contact instantaneous delayed instantaneous opening opening closing Stop-category 0 Stop-category 1 Stop-category 0 Rated operational voltage 300 V 300 V Rated operational current AC (resistive) 5 A (at 240 V) 2.5 A (at 240 V) Rated operational current AC 15 (inductive) 1.5 A (at 240 V) 0.75 A (at 240 V Rated operational current DC (resistive) 5 A (at 24 V) 2.5 V (at 230 V) Rated operational current DC 13 (inductive) 4 A (at 24 V) L/R=50 ms 2 A (at 230 V) Short-circuit protection, max. fuse rating 6 A, fast / type gl 4 A fast / type gl Limit of accum. currents at simultaneous load on several output circuits Σ current Ith < 8 A Impulse withstand voltage Vimp Response time of the output relays < 20 ms Mechanical life (max.) 10 x10 6 operations Electrical life (max.) (on AC / 230 V / 2.5 A) 6 x 10 5 operations -10 C C -40 C C Mounting on DIN rail (EN 500) snap-on mounting/screw mounting using adapter Terminal capacity 2 x AWG (2 x 2.5 mm 2 ) Weight 24 V AC/DC / 115 V AC and 230 V AC approx lb (650 g) / approx lb (850 g) Accessories Dimensions (W x H x D) 90 x 78 x 0 mm Sealable shroud
10 E Delay on release Safety relay E-3+2 For emergency stop monitoring Functional diagram With start button 1 = monitoring, 2 = not monitoring N/C1 (1 st contact) N/C2 (2 nd contact) Start button Start button External start conditions (ESC) Output 13- (N/O) Output (N/O) Output (N/O) Output (N/C) Output (N/O) Output (N/O) Supply Start Emergency voltage not operated stop operated 1 With start button monitoring (connection Y3-Y5) 2 Without start button monitoring (connection Y3-Y4) TV = s adjustable Without start button Link from Y2 to S33 N/C1 (1 st contact) N/C2 (2 nd contact) Start button Start button External start conditions (ESC) Output 13- (N/O) Output (N/O) Output (N/O) Output (N/C) Output (N/O) Output (N/O) Emergency not operated stop operated 75 ms t maxi. TV = s adjustable Connecting diagram S1 : button with 2 N/C contacts (recommended application) Output must not be used as a safety circuit. (1) With start button monitoring (2) Without start button monitoring ESC : External start conditions : Feedback loop Wiring diagram Connection with one emergency stop button (without cross circuit monitoring) Connection of several emergency stop buttons S1: button with 2 contacts (a short-circuit between the 2 inputs is not detected) Configuration with start button monitoring Monitoring of an emergency stop with one contact Configuration without start button monitoring S1: button with 1 N/C contact Not all faults are detected: a short-circuit on the emergency stop button is not detected 1752
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Preventa Machine Safety Products
Preventa Machine Safety Products Catalog 2009 200 Supplement Safety Relay Modules 2 Contents Preventa safety relay modules Selection guide 2 Electrical Ratings 6 Types XPSAC and XPSAXE For Emergency stop
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
PNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
Safety Relays ESM/ESM-F
Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
E-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous
PROTECT. Safety Relay Modules PROTECT-SRB s Catalogue Protect/04
PROTECT Safety Relay Modules PROTECT-SRB s Catalogue Protect/04 Subject to technical modifications and error. The data specified in this catalogue are carefully checked typical standard values. Or as the
E-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
E-STOP relays, safety gate monitors
Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
Contact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Contact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43
Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43 The three-phase monitoring relay CM-MPS.43 monitors the phase parameters phase sequence, phase failure, over- and undervoltage
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
Pluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
CONFIGURABLE SAFETY RELAYS
MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
SMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
Control Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
E-STOP relays, safety gate monitors
Unit features Unit description Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),
Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
Safety Manual BT50(T) Safety relay / Expansion relay
Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document
Bul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, GLP, EM, and EMD) Selection Guide
Bul. R Guardmaster Safety Relays () Selection Guide Bulletin R Description The new generation of Guardmaster safety relays addresses the broad scope of applications in the intricate safety world with a
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6
W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions
PHOENIX CONTACT - 2012-12-14. Features
Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous
E-STOP relays, safety gate monitors
Unit features Unit description Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
instabus KNX / EIB System System E F G H
Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA
49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
CONFIGURABLE SAFETY RELAYS
MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Reference. 910 402 230 V, 50 Hz A10 415 120 V,60 Hz. 916 402 230 V, 50/60 Hz A16 418 120 V, 50/60 Hz. 910 103 230 V, 50 Hz A10 104 120 V, 60 Hz
Rex - analog time switches MicroRex - 3 modules for DIN rail mounting Rex - analog time switches MicroRex - module for DIN rail mounting 926 428 A0 4 MicroRex T3 24 hour program, synchronous motor 92 429
ABB STOTZ-KONTAKT GmbH ABB i-bus KNX Switch Actuators SA/S
place picture here STO/GM/GS Juli 2011 ABB STOTZ-KONTAKT GmbH ABB i-bus KNX Switch Actuators SA/S A Complete Range 15.11.2011 DESTO Jürgen Schilder 2 A Complete Range Switch Actuators are responsible for
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
Manual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V
Description: The universal signal converter offers threeway isolation and translates one input control signal into one to three simultaneous outputs. Switches allow the user to select the desired input
Bimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
Specifications for EM223 24 VDC 4 In/4 Out and EM223 24 VDC 4 In/4 Relay Out
SIMATIC S7-200 EM223 Digital Combination Modules EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out Table 1 Specifications for EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out EM223 2VDC In/Out 6ES7 2231BF200XA0
Preset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
Features, Benefits, and Operation
Features, Benefits, and Operation 2014 Decibel Eleven Contents Introduction... 2 Features... 2 Rear Panel... 3 Connections... 3 Power... 3 MIDI... 3 Pedal Loops... 4 Example Connection Diagrams... 5,6
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
Protect IT MNS Motor Management INSUM. MPU - Multi Purpose Unit. - Catalogue - ABB
Protect IT MNS Motor Management INSUM MPU - Multi Purpose Unit - - ABB INSUM Multi Purpose Unit Revision 1.6 2 NOTICE The information in this document is subject to change without notice and should not
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Catalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
Relés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
13 SERIES. Electronic step relays 10-16 A 13.81 13.91
13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
Digital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20
Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description