CABLES. Single Core Conductor BETAtherm 155 UL. Description. Properties. Application. Standards

Similar documents
Chemical resistance Accidental

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

Tri-Rated Flexible PVC Equipment Wire

The Quality Connection. BETAflam Fire Resistant Safety Cables

VIPERFLEX ELECTRIC CABLE

Flexible Control Cables

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

with coloured cores and overall copper screen UL/CSA... 17

Cable flexibility Flexible. Chemical resistance Accidental

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

Building Cables and Wires

CONFLEX ELECTRIC CABLE

Flexible cables for submersible products

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr /2009

Fire retardant IEC

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

VDE-approved PVC-Control Cables

MICROCABLES. A complete vision of your connectivity needs. Catalogue

Power and Wiring Cables

600V Power Cable 600V SOOW SOW

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

APR 2016 Rev M

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

5.2. Overview. The better method to install solderless compression connectors on power cable

COAX Cables Radio Frequency Cables

Flygt flexible cables

ISO VIEW OF AX SERIES XLR CABLE CONNECTOR

Festoon 715 P PUR cable for flexible application in festoon systems

< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10

MV CABLE TYPE C

C A B L E P R O T E C T I O N

KNOW YOUR OPTIONS: 230 KV POWER CABLES

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

400 Series Buccaneer BUCCANEER POWER. bulgin

ISO 9001 ISO CABLES AND WIRES CATALOGUE 2008

Section kv Power Cables

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT Phone: Fax:

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

3M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series

Hook-Up and Lead Wire

Gulf Cable & Electrical Ind. Co.

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

PTC-Resistor Temperature-Sensors MINIKA to DIN and DIN

Instrumentation Cable Power Cable Assembly Solutions...32

Outside Telephone Cable

Directory chapter 04

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

Servo Motor & Drive Cables

Global cable expertise for rolling stock

ETHERLINE Ethernet Cable, Connectors & Tools

TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

SPEC 55. Wire and cable. Applications. SPEC 55PC wire and cable insulation system. Features and benefits. Physical characteristics

TECHNICAL SPECIFICATION

HARTING Ethernet Cabling 4-poles Overview

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

ACS-30-EU-EMDR-10-MOD

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

FIBER-OPTIC CABLES LWL-KABEL

ZS10 Screw Clamp Terminal Block

Series 8146/5-V37 and Series 8150/5-V37

Panduit 28 AWG Patch Cords Installation Guideline

Universal MATE-N-LOK Connectors

AMP Standard Terminals and Splices. RoHS. Ready

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

Automotive Wire and Cable Products

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Allweather and Rubber Cables

Communication, Signal & Data Cables

3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series

Thermal-Magnetic Circuit Breaker M1-..

HARTING Ethernet Cabling 8-poles Overview

Standard Buccaneer - Ethernet

the quality par excellence Meghna Industries Manufacturer of : All types of fiberglass Cables

Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts

Specification SFTP CAT6 Network Cable 23AWG CU

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

CONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6

A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies

RF & Microwave cable assemblies C291

100% EMI Emission Containment

CONTENT. Robot cables NEW. page. < The company < W - worldwide < Clientele / supplier numbers < Cables for dress package...

Flexible Cables and Cords

Block width on rail (mm) Standard block* is shown on blue background

Cable & Accessories for Wind Turbines

The range of rail-mounted terminal blocks. for a perfect electrical installation.

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Electronics and Soldering Notes

Universal MATE-N-LOK Connector System

BUS 1010F Cavo per posa fissa (INTERBUS Remote Bus, 2-wire) INTERBUS cable for fixed installation

Self-Regulating Low Temperature Heating Cable

Photo: HELUKABEL. Cables according to International Approvals N 1

PROTECH ELECTRICAL CONNECTORS AND CABLE TIES

6000 Series Buccaneer

RADOX railway cables acc. to EN and EN Edition 2009

Transcription:

Description Properties BETAtherm 155 UL is a flexible low-voltage cable with UL recognition, consisting of a tinned copper stranded wire and insulated with coloured electron-beam crosslinked polyolefine copolymer. Due to its electron-beam cross-linked insulation, BETAtherm 155 UL achieves a special thermal resistance required for Class F. This results in excellent thermal resistance. However, it cannot even be melted at elevated temperatures and has to be skinned during processing. Skinning is simple and also possible at machines. BETAtherm cables are resistant to all common insulating varnishes. They are flame retardant. Application BETAtherm 155 UL is suitable for the internal wiring of electric machines, lamps, heating appliances, as well as for application in apparatus, mechanical and plant engineering. Due to the high thermal load capacity, it might be possible to reduce the conductor cross section and, therefore, save space and reduce the weight. Standards Thermal class F (155 C) UL AWM Style 3289 and CSA CL 1503 RoHS compliant according to 2002/95 EC

Conductor Tinned copper wire VDE 0295/ IEC 60228 class 5. The dimensions specified in the technical datasheet are regarded as standard values. The actual cross sections may vary. The cables are manufactured according to European standards with a metric conductor cross section, AWG sizes are approximate values and viceversa. Always observe relevant standards valid for divergent operating conditions when laying for greater limit current loads. Colour Delivery format Green/yellow, black, light blue, dark blue, brown, red, white, grey, violet, orange, yellow, green. Other colours, also two colours, available on request. Metric dimensions mm² rings AWG dimensions ring 4.0 10.0 100 m 24-14 300 m 16.0 25.0 50 m 35.0 95.0 25 m Other cross sections available on request

Thermal Electrical Thermal class F Temperature range Fixed application: -55 to +155 C +150 C UL3289 Short circuit: +280 C Thermal resistance IEC 60216-2 / VDE 304 T 21 (155 C/5000h) Behaviour in fire Flame retardant IEC 60332-1. VDE0472 T. 804 B Nominal voltage U 0 /U 300/500 V 1 mm² U 0 /U 450/750 V 1.5 mm² Nominal voltage with fixed U 0 /U 600/1000 V 1.5 and protected mm² application U 0 /U 600/600 V UL 3289 Testing voltage 5000 V/ 50 Hz/ 2 min Mechanical Chemical Bend radius Soldering resistance Insulation Resistance 4 x outer diameter Very good Electron-beam cross-linked polyolefine copolymer Resistant to common impregnants

Metric dimensions (UL Style 3289) Nominal cross section [mm²] Strands x diameter [standard values] Copper strand nominal diameter Wall thickness Desir ed UL min. Outer 0.25 14 x 0.15 0.66 2.26 ± 0.10 0.5 16 x 0.20 0.90 2.50 ± 0.10 0.75 24 x 0.20 1.15 2.75 ± 0.10 1 32 x 0.20 1.25 2.85 ± 0.10 1.5 27 x 0.25 1.55 0.80 0.686 3.15 ± 0.20 2.5 45 x 0.25 2.05 3.65 ± 0.20 4 52 x 0.30 2.55 4.15 ± 0.20 6 78 x 0.30 3.10 4.70 ± 0.20 10 75 x 0.40 4.10 1.20 1.029 6.50 ± 0.30 16 119 x 0.40 5.50 8.70 ± 0.30 25 182 x 0.40 6.60 1.60 1.372 9.80 ± 0.30 35 259 x 0.40 7.70 10.90 ± 0.40 50 380 x 0.40 9.90 14.30 ± 0.40 70 342 x 0.50 11.90 2.20 1.829 16.30 ± 0.40 95 456 x 0.50 13.20 17.60 ± 0.40

AWG dimensions (UL Style 3289) Nominal cross section Strands x diameter [standard values] Copper strand nominal diameter Wall thickness Desired min. Outer AWG 24 (0.24 mm 2 ) 19 x 0.127 0.68 2.28 ± 0.05 AWG 22 (0.38 mm 2 ) 19 x 0.160 0.84 2.44 ± 0.05 AWG 20 (0.61 mm 2 ) 19 x 0.203 1.06 2.66 ± 0.05 AWG 18 (0.96 mm 2 ) 19 x 0.254 1.32 0.80 0.686 2.92 ± 0.05 AWG 16 (1.34 mm 2 ) 19 x 0.300 1.55 3.15 ± 0.10 AWG 14 (2.38 mm 2 ) 19 x 0.400 2.05 3.65 ± 0.10 4 mm 2 (AWG 12) 52 x 0.30 2.55 4.15 ± 0.20 6 mm 2 0.80 0.62 (AWG 10) 78 x 0.30 3.10 4.70 ± 0.10 10 mm 2 (AWG 8) 75 x 0.40 4.10 6.10 ± 0.20 16 mm 2 1.00 0.80 (AWG 6) 119 x 0.40 5.50 7.50 ± 0.20 25 mm 2 (AWG 4) 182 x 0.40 6.60 9.00 ± 0.20 35 mm 2 1.20 0.98 (AWG 2) 259 x 0.40 7.70 10.10 ± 0.20 50 mm 2 (AWG 1) 380 x 0.40 9.90 12.70 ± 0.20 70 mm 2 1.40 1.16 (AWG 2/0) 342 x 0.50 11.90 14.70 ± 0.20 95 mm 2 (AWG 3/0) 456 x 0.50 13.20 1.60 1.34 16.40 ± 0.30 (Values in brackets: corresponding AWG or metric dimensions)