LABORATORY 1 WRITEUP - PHYSICS 517/617. Prof. L. S. Durkin July 5, 1992

Similar documents
Inductors in AC Circuits

Lab E1: Introduction to Circuits

Electrical Resonance

LAB 7 MOSFET CHARACTERISTICS AND APPLICATIONS

Reading: HH Sections , (pgs , )

Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321)

Lab 1: DC Circuits. Student 1, Partner : Student 2, student2@ufl.edu

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

Lock - in Amplifier and Applications

EXPERIMENT NUMBER 8 CAPACITOR CURRENT-VOLTAGE RELATIONSHIP

Frequency Response of Filters

Laboratory 4: Feedback and Compensation

PHYSICS 111 LABORATORY Experiment #3 Current, Voltage and Resistance in Series and Parallel Circuits

Understanding Power Impedance Supply for Optimum Decoupling

Experiment 5. Strain Gage Measurements

CIRCUITS LABORATORY EXPERIMENT 3. AC Circuit Analysis

LABORATORY 2 THE DIFFERENTIAL AMPLIFIER

RLC Series Resonance

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

Step Response of RC Circuits

DRIVING LOOOONG CABLES

Reading assignment: All students should read the Appendix about using oscilloscopes.

Physics 120 Lab 6: Field Effect Transistors - Ohmic region

Measuring Impedance and Frequency Response of Guitar Pickups

= V peak 2 = 0.707V peak

SERIES-PARALLEL DC CIRCUITS

PROCEDURE: 1. Measure and record the actual values of the four resistors listed in Table 10-1.

Rectifier circuits & DC power supplies

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

Lab #4 Thevenin s Theorem

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT

Measurement of Capacitance

The 2N3393 Bipolar Junction Transistor

11: AUDIO AMPLIFIER I. INTRODUCTION

Technical Note #3. Error Amplifier Design and Applications. Introduction

BJT Characteristics and Amplifiers

Experiment #5, Series and Parallel Circuits, Kirchhoff s Laws

Op-Amp Simulation EE/CS 5720/6720. Read Chapter 5 in Johns & Martin before you begin this assignment.

Oscilloscope, Function Generator, and Voltage Division

Common Emitter BJT Amplifier Design Current Mirror Design

Electricity & Electronics 5: Alternating Current and Voltage

VOLTAGE REGULATOR AND PARALLEL OPERATION

Scaling and Biasing Analog Signals

See Horenstein 4.3 and 4.4

Measuring Electric Phenomena: the Ammeter and Voltmeter

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

EE362L, Power Electronics Triac Light Dimmer

Q1. The graph below shows how a sinusoidal alternating voltage varies with time when connected across a resistor, R.

Experiment1: Introduction to laboratory equipment and basic components.

Transistor Amplifiers

Fundamentals of Signature Analysis

Properties of electrical signals

Equipment: Power Supply, DAI, Transformer (8341), Variable resistance (8311), Variable inductance (8321), Variable capacitance (8331)

Experiment 2 Diode Applications: Rectifiers

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

V out. Figure 1: A voltage divider on the left, and potentiometer on the right.

Transistor Characteristics and Single Transistor Amplifier Sept. 8, 1997

RC & RL Transient Response

The accelerometer designed and realized so far is intended for an. aerospace application. Detailed testing and analysis needs to be

Series and Parallel Resistive Circuits Physics Lab VIII

Electronic WorkBench tutorial

Experiment NO.3 Series and parallel connection

Application Note. So You Need to Measure Some Inductors?

The W5JCK Guide to the Mathematic Equations Required for the Amateur Extra Class Exam

Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz

AC CIRCUITS - CAPACITORS AND INDUCTORS

ENGR-4300 Electronic Instrumentation Quiz 4 Spring 2011 Name Section

EE 1202 Experiment #4 Capacitors, Inductors, and Transient Circuits

DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b

Series and Parallel Circuits

PHASOR DIAGRAMS HANDS-ON RELAY SCHOOL WSU PULLMAN, WA. RON ALEXANDER - BPA

Homework Assignment 03

12. Transformers, Impedance Matching and Maximum Power Transfer

Line Reactors and AC Drives

30. Bode Plots. Introduction

Application Note #49 RF Amplifier Output Voltage, Current, Power, and Impedance Relationship

Circuit Analyses. Laboration 1 how to measure Current and Voltage and Resistance

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

Measuring Resistance Using Digital I/O

1. The Slotted Line. ECE 584 Microwave Engineering Laboratory Experiments. Introduction:

DRAFT. University of Pennsylvania Moore School of Electrical Engineering ESE319 Electronic Circuits - Modeling and Measurement Techniques

Lab 3 - DC Circuits and Ohm s Law

Section 3. Sensor to ADC Design Example

BASIC ELECTRONICS AC CIRCUIT ANALYSIS. December 2011

ARRL Morse Code Oscillator, How It Works By: Mark Spencer, WA8SME

Tristan s Guide to: Solving Parallel Circuits. Version: 1.0 Written in Written By: Tristan Miller Tristan@CatherineNorth.com

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

The Time Constant of an RC Circuit

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

Chapter 22 Further Electronics

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Lab #9: AC Steady State Analysis

Measuring Insulation Resistance of Capacitors

S-Parameters and Related Quantities Sam Wetterlin 10/20/09

OPERATIONAL AMPLIFIERS

Chapter 13: Electric Circuits

Chapter 10. RC Circuits ISU EE. C.Y. Lee

The Critical Length of a Transmission Line

Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49

Transcription:

LABORATORY 1 WRITEUP - PHYSICS 517/617 Prof. L. S. Durkin July 5, 1992 DISCLAIMER: There are many ways to write up a lab report, none of them superior to any other. Below is an example of an acceptable report. It is not necessary to generate typewritten text or computer plots. Computer plots are easier to generate and fit than hand plots, but feel free to plot things by hand. Information is what counts, not style. I.1 Purpose The purpose of this measurement is to verify Ohm's law (V=IR) for constant voltages and constant currents. Two resistors will be used with resistances varying by nearly three orders of magnitude. I.2 Procedure The current and voltages will be measured using a Fluke meter. I have chosen resistors: 1. R=1100 ± 5% Ω (1088 Ω measured with meter), and 2. R=1.20 ± 5% MΩ (1.21 ΜΩ measured with meter). I.3 Data Table 1 R = 1100 Ω Voltage Resistor (V) Current Resistor (ma) 0.0 0.00 16.0 15.5 4.0 3.70 13.0 12.5 5.6 5.03 11.5 10.12 My measurements were taken alternately between high and low values to reduce any effects due to equipment drift (Resistor heating...).

Note: My voltage supply started smoking half way through the data taking. I replaced it and don't expect this to have any effect. Table 2 R = 1.2 MΩ Voltage Resistor (V) Current Resistor (ma) 0.00 0.00 30.5 0.028 5.5 0.005 29.9 0.025 10.67 0.010 18.00 0.014 Note: I had a faulty wire which made these measurements difficult. I was forced to rewire several times. I.4 Data Analysis The data plots for the two resistors are shown in figures 1 and 2 below. FIGURE 1 DC Voltage-Current R = 1100 Ω For the R=1100 Ω resistor, the line is seen to be a very good fit. The values agree with the line within the measurement errors listed below ( 2 %).The slope of the line is not in very good agreement with the resistance measured by the meter. I went back and check this resistance and

could find no problem. I don't understand this 4 % discrepancy giventhis result is a fit to many points (Error should reduce by 1/ N ). FIGURE 2 DC Voltage-Current R = 1.2 MΩ For the 1.2 MΩ resistor once again the line seems to be a good fit to the data. The values agree with the line within measurement errors (see below). The slope once again is 4 % lower than the value I measured with the voltmeter. In this case I think I have an explanation. Since the internal resistance of the meter is 10 MΩ (see later in lab book), and I am using a 1.0 MΩ resistor, I might expect to be low by nearly 10 %. Possible sources of measurement error are simple here: The current measurement in the FLUKE manual has an error of 1 %. The voltage measurement is good to the digital display accuracy (about 1 %). The resistance measurement is good to the digital display accuracy (about 1 %). Possible sources of systematic error are: The resistor could heat up changing the resistance. Since my currents are low this effect should be negligible. I also staggered my measurements to protect against this problem. II.1 Purpose The purpose of this measurement is to verify Ohm's law (V=IR) for sinusoidal voltages and currents. One resistor will be used at two varying frequencies: 100 Hz and 50 KHz.

II.2 Procedure The current and voltages will be measured using a Fluke digital volt meter (D.V.M) (Thus R.M.S. measurements). I have chosen a resistor: R=560 ± 5% Ω(563 Ω measured with meter). II.3 Data Table 3 R = 560 Ω, f = 100 Hz Voltage Resistor (rms V) Current Resistor (rms ma) 0.042 0.08 0.144 0.26 4.07 7.250 0.414 0.74 3.120 5.550 1.312 2.34 3.56 6.33 1.881 3.35 2.586 4.60 Table 4 - R = 560 Ω, f = 50 KHz Voltage Resistor (rms V) Current Resistor (rms ma) 0.000 0.02 0.035 0.06 0.12 3.23 0.077 1.78 0.106 2.79 Note: The current measurements when taking this data were very unstable. The meter would suddenly fall to zero and I would have to turn off the meter to get a reading. A quick ratio with the calculator shows the effective resistance is way off. I had better take some data to investigate.

Try keeping the voltage constant, I change the frequency measuring the current. Table 5 - R = 560 Ω, V =.120 V frequency Current Resistor (rms ma) 100 0.21 1000 0.22 2000 0.23 3000 0.23 4000 0.23 5000 0.28 8000 0.37 10000 0.46 20000 unstable 30000 1.6 Note: Once again the current meter is very unstable. At 20KHz it was impossible even to obtain a reading. The DVM varied from.0-.7 ma rms. II.4 Data Analysis In figure 3 is shown the Ohms law data for 100 Hz. The straight line agrees with the fit line well within measurement errors (see below). The resistance from the slope also agrees well, within the expected errors of 2 %, with the resistance measured from the meter.

FIGURE 3 50 Hz, R = 560 Ω, Values are R.M.S. In figure 4 is shown the Ohms law data for 50 KHz. There are immediate problems seen in this data. It doesn't pass through zero. The best fit slope doesn't agree with the resistor used at all. Looking at the FLUKE manual it only gives a meter accuracy below 1 KHz. I suspect this means it doesn't work above 1 KHz. To investigate this I took the data in figure 5. It is seen the FLUKE meter works well up to about 5 KHz and then the measurement takes off. I had better believe the FLUKE book and only use the DVM below 1 KHz in the future. FIGURE 4 50 KHz, R = 560 Ω, Values are R.M.S.

FIGURE 5 Current through a 560 Ω resistor as a function of the frequency with the voltage across the resistor fixed at.120v. Values plotted are R.M.S. Possible sources of measurement error (Below 1 KHz) are simple here: The current measurement in the FLUKE manual has an error of 1 %. The voltage measurement is good to the digital display accuracy (about 1 %). The resistance measurement is good to the digital display accuracy (about 1 \%). Possible sources of systematic error are: The resistor could heat up. Since my currents are low this effect should be negligible. I also staggered my measurements to protect against this problem. Clearly the meter does not operate much above 1 KHz. III.1 Purpose The purpose of this section is to measure the internal resistance of the DVM when measuring voltage. III.2 Procedure

In the circuit above the external resistance and external voltage are known. The voltage measured by the voltmeter is known, and thus the only unknown is the internal resistance.thus the equation for the internal resistance is: Vm R m = R 1. V - Vm For two resistors we measure V and V m using the DVM. III.3 Data All resistors were measured with a DVM. Table 6 - DVM Internal Resistance R1 (MΩ) V (volts) Vm (volts) R(internal) (MΩ) 18.29 5.00 2.79 10.2 18.29 10.00 3.55 10.0 18.29 20.00 7.05 10.0 9.40 5.20 5.20 8.8 III.4 Data Analysis It is seen from the calculated R internal in table 6 that the DVM internal resistance is about 10 MΩ. There seems to be little error associated with voltage measurement as can be seen from the first three measurements in this table. Changing resistors did cause a 10 % change in my measured value. I don't fully understand this change. It is not explained by the measurement errors discussed below. Possible sources of measurement error are: The voltage measurement is good to the digital accuracy (about 1 %). The resistance measurement is good to the digital accuracy (about 1 %). Possible sources of systematic error are: There seems to be some unknown effect here. Since I don't have a schematic of the DVM it is impossible for me to guess what the effect is. I could plot the measured resistor as a function of external resistance to see if there is a real effect. Unfortunately I thought of this too late to include it in this lab. IV.1 Purpose The purpose of this section is to measure the internal resistance and capacitance of the

oscilloscope. IV.2 Procedure Capacitors block DC voltage and thus can be ignored in this circuit. My circuit is then identical to the circuit in section III.2. The formulas for resistance is as before: Vm R m = R 1 V - Vm Measurements of V and V m are made using the oscilloscope. For high enough frequency the impedance of a capacitor becomes very small with respect to the impedance of a resistor. In this limit (1/ω c << R ), adding an external capacitor, we obtain the following circuit. In order to satisfy this limit we must have : ω >> 1/RC = 2800 rad/sec. I therefore choose f= 100Khz. In this limit my equation becomes: V - Vm C m = C1 V I once again measure V and V m using the oscilloscope. I measure C 1 with the capacitance meter in the lab. IV.3 Data DC voltage source to measure R internal for scope. R 1 measured with DVM. Table 7 - Oscilloscope Internal Resistance R1 (MΩ) V (volts) Vm (volts) R(internal) (MΩ) 1.087 5.00 2.45 1.04 1.087 10.00 4.90 1.04 0.528 5.00 2.61 1.10 m Frequency generator ( f = 100 KHz) was used as the source. The frequency meter was tuned to lower frequencies to check that frequency did not effect the answers. Measured voltages only changed in the vicinity of 1 KHz, which is in good agreement with the calculation above. The capacitance, C 1, was measured with the capacitance meter in the lab. V and V m were measured on the oscilloscope.

Table 8 - Oscilloscope Internal Capacitance C1 (pf) V (volts) Vm (volts) C internal (pf) 46.9 6.0 1.48 143 46.9 10.00 2.40 149 24.6 6.0 0.80 160 24.6 10.00 1.30 165 IV.4 Data Analysis The resistance measurements of Table 7 seem quite consistent. The internal resistance of the scope is 1.0 ΜΩ with a percentage error of around 5 %. I used my DVM to measure the internal resistance of the scope and obtained 1.01 MΩ as the internal resistance of the scope. Possible sources of measurement error are: Measuring voltage off the oscilloscope is limited by reading accuracy. If I can't distinquish half a small division my accuracy will be limited to.5/10-50 or 1-5 %. Measurement error of resistance from the DVM is negligible. Possible sources of systematic error are: There is not much systematic error one can think of except for scope calibration, and that has been cross checked with the DVM. The capacitance measurements of Table 8 do not seem very consistent. There seems to be greater than a 10 % difference in the answer when I change my C 1 value. Even more shocking is the difference with the manual for the scope which claims and internal capacitance of 35 pf. To check the internal capacitance of the scope I used the capacitance meter in the lab and read the capacitance as 35 pf. After playing with the circuit I found that the leads attaching to the circuit had large capacitances. I measured my leads to have a capacitance of 110 pf using the capacitance meter in the lab. Subtracting this off from the results in Table 8, I get the internal capacitance of the scope to be somewhere around 36-50 pf. Possible sources of measurement error are: Measuring voltage off the oscilloscope is limited by reading accuracy. If I can't distinquish half a small division my accuracy will be limited to.5/10-50 or 1-5 %. Measurement error of capacitance from capacitance meter is negligible.

Possible sources of systematic error are: The error on this measurement is dominated by stray capacitances. The lead capacitances are bigger than the capacitance of the scope.even using very short leads one is worried one has not eliminated all stray capacitances. V.1 Purpose The purpose of this measurement is cross check the calibration of the frequency meter and the oscilloscope over the full frequency range of the frequency meter. V.2 Procedure A frequency is dialed on the frequency meter, and then the frequency of the output sine wave is measured using an oscilloscope. V.3 Data Table 9 - Calibration Data frequency Meter (Hz) frequency Oscilloscope (Hz) 10 12.6 100 104.7 1000 1047 10000 12500 100000 114000 50 50 500 510 5000 5040 50000 52600 500000 541000 V.4 Data Analysis Shown in figure 6 is a plot of the meter frequency vs the oscilloscope frequency. The relationship seems to be very linear despite KALIDOGRAPH's idiotic curve. This seems to be a bug in KALIDOGRAPH. It won't plot a straight line on a log-log plot. For a commercial piece of software this is inexcusable. I can't fix it so I ignore it. The linear fit does show an interesting effect. The oscilloscope and the meter reading seem to disagree by over 8 %. It is impossible, without doing something else, to check who is right. I could independently calibrate the oscilloscope by looking at the 60 Hz 120 V signal being put out by the electric company. I am too afraid of being electrocuted so I don't do it. I instead trigger my oscilloscope on the line voltage and dial 60 Hz on the frequency generator. It looks like my oscilloscope is accurate. Thus my frequency generator dial can't be totally trusted. Such is life!

Possible sources of measurement error are: Measuring frequency off the frequency meter dial is only accurate to about 5 %. Measuring frequency off the oscilloscope is limited by reading accuracy. If I can't distinquish half a small division my accuracy will be limited to.5/10-50 or 1-5 %. Possible sources of systematic error are: As I have shown the knob on the frequency generator is somewhat misplaced. FIGURE 6 Frequency as measured on the frequency generator vs frequency measured on the oscilloscope. Funny line is an artifact of KALIDOGAPH (see text).