2D Detectors for Powder X-ray Diffraction: Data Reduction and Rietveld Refinements

Similar documents
Structure Factors

Introduction to X-Ray Powder Diffraction Data Analysis

Powder diffraction and synchrotron radiation

Fraunhofer Diffraction

ESRF Upgrade Phase II: le nuove opportunitá per le linee da magnete curvante

Lab 4: Magnetic Force on Electrons

Experiment: Crystal Structure Analysis in Engineering Materials

Electron density is complex!

Proton tracking for medical imaging and dosimetry

Magnetic Fields and Their Effects

X-ray thin-film measurement techniques

X-Ray Diffraction HOW IT WORKS WHAT IT CAN AND WHAT IT CANNOT TELL US. Hanno zur Loye

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

Polarization Dependence in X-ray Spectroscopy and Scattering. S P Collins et al Diamond Light Source UK

Laue lens for Nuclear Medicine

How To Understand Light And Color

X-ray diffraction techniques for thin films

Physics 221 Experiment 5: Magnetic Fields

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Wir schaffen Wissen heute für morgen

6) How wide must a narrow slit be if the first diffraction minimum occurs at ±12 with laser light of 633 nm?

Applications of New, High Intensity X-Ray Optics - Normal and thin film diffraction using a parabolic, multilayer mirror

2 Absorbing Solar Energy

Pendulum Force and Centripetal Acceleration

Information about the T9 beam line and experimental facilities

ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES

Introduction to Powder X-Ray Diffraction History Basic Principles

Acousto-optic modulator

ON-STREAM XRF ANALYSIS OF HEAVY METALS AT PPM CONCENTRATIONS

F B = ilbsin(f), L x B because we take current i to be a positive quantity. The force FB. L and. B as shown in the Figure below.

Physics 111 Homework Solutions Week #9 - Tuesday

Diffraction Course Series 2015

ISTITUTO NAZIONALE DI FISICA NUCLEARE

Cathode Ray Tube. Introduction. Functional principle

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

Manual for simulation of EB processing. Software ModeRTL

Magnetic Field of a Circular Coil Lab 12

Rotation: Moment of Inertia and Torque

A.Besson, IPHC-Strasbourg

Rapid structure determination of disordered materials: study of GeSe 2 glass

Neutron Resonance Spectroscopy for the Characterisation of Materials and Objects

Using light scattering method to find The surface tension of water

DICOM Correction Item

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Acquiring molecular interference functions of X-ray coherent scattering for breast tissues by combination of simulation and experimental methods

A Guide to Acousto-Optic Modulators

Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission

Physics 441/2: Transmission Electron Microscope

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Optical Design Tools for Backlight Displays

Chapter 7: Basics of X-ray Diffraction

Experimental study of beam hardening artefacts in photon counting breast computed tomography

Chapter 27 Magnetic Field and Magnetic Forces

Lecture 14. Point Spread Function (PSF)

Crystal Structure of High Temperature Superconductors. Marie Nelson East Orange Campus High School NJIT Professor: Trevor Tyson

Lectures about XRF (X-Ray Fluorescence)

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Relevant Reading for this Lecture... Pages

POSSIBL-E EXPERIMENTS ON THE 200-GeV ACCELERATOR. A. D. Krisch University of Michigan. R. Serber Columbia University.

Damping Wigglers in PETRA III

Solar Energy. Outline. Solar radiation. What is light?-- Electromagnetic Radiation. Light - Electromagnetic wave spectrum. Electromagnetic Radiation

Spectroscopy Using the Tracker Video Analysis Program

Theremino System Theremino Spectrometer Technology

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

Phys222 Winter 2012 Quiz 4 Chapters Name

ELECTRON SPIN RESONANCE Last Revised: July 2007

EDXRF of Used Automotive Catalytic Converters

Cryo SAXS sample environment Project update 02/2007

Pre-lab Quiz/PHYS 224 Magnetic Force and Current Balance. Your name Lab section

EDS system. CRF Oxford Instruments INCA CRF EDAX Genesis EVEX- NanoAnalysis Table top system

Electron Microprobe Analysis X-ray spectrometry:

PARALLEL BEAM METHODS IN POWDER DIFFRACTION AND TEXTURE IN THE LABORATORY.

Development of on line monitor detectors used for clinical routine in proton and ion therapy

Zero Degree Extraction using an Electrostatic Separator

Blue Laser Technology Applied to the Microtrac Unified Scatter Technique for Full- Range Particle Size Measurement.

The accurate calibration of all detectors is crucial for the subsequent data

Hydrostatic Force on a Submerged Surface

Cabri Geometry Application User Guide

INTERFERENCE OF SOUND WAVES

Passive Remote Sensing of Clouds from Airborne Platforms

Nanoelectronics 09. Atsufumi Hirohata Department of Electronics. Quick Review over the Last Lecture

GAMMA-RAY SPECTRA REFERENCES

Electron Microscopy SEM and TEM

E/M Experiment: Electrons in a Magnetic Field.

Physics 202 Problems - Week 8 Worked Problems Chapter 25: 7, 23, 36, 62, 72

D/N VARI-FOCAL IR CAMERA

STUDY OF THE TRANSVERSE BEAM EMITTANCE OF THE BERN MEDICAL CYCLOTRON

Scanning Electron Microscopy: an overview on application and perspective

Cross-beam scanning system to detect slim objects. 100 mm in

Physics 25 Exam 3 November 3, 2009

Wir schaffen Wissen heute für morgen. Paul Scherrer Institut Bernd Schmitt Jungfrau, Mönch and Eiger: Detector Development at the Swiss Light Source

Silicon Seminar. Optolinks and Off Detector Electronics in ATLAS Pixel Detector

Full credit for this chapter to Prof. Leonard Bachman of the University of Houston

Aerodynamic Design Optimization Discussion Group Case 4: Single- and multi-point optimization problems based on the CRM wing

Dose enhancement near metal electrodes in diamond X- ray detectors. A. Lohstroh*, and D. Alamoudi

Transcription:

2D Detectors for Powder X-ray Diffraction: Data Reduction and Rietveld Refinements Anthony Arulraj Ramanujan Fellow MSG, IGCAR 25 JANUARY 2012 RRCAT, INDUS II MEETING

Outline Introduction : 2D diffraction, Area detectors Data Reduction Procedures as implemented in FIT2D Program Rietveld Refinements: examples from own Research

2D diffraction

E6 Focusing diffractometer at BENSC

Cartoon of an IP detector perpendicular to the X-ray beam

Types of Area Detectors Detector types Comparison can be made using the following technical details: Detective Quantum Effciency (DQE), Point spread function, size, speed, dynamic range Ref. Powder Diffraction: Theory and Practice

Types of Area Detectors Mar345 IP detector CMOS hybrid-pixel technology Pilatus 2M detector Detector types Comparison Technical specifications Number of modules 3 8 = 24 Sensor Reverse-biased silicon diode array Sensor thickness 320 µm Pixel size 172 172 µm2 Format 1475 1679 = 2,476,525 pixels Area 254 289 mm2 Intermodule gap x: 7 pixels, y: 17 pixels, 8.0 % of total area Dynamic range 20 bits (1:1,048,576) Counting rate per pixel > 2 x 10^6 X- ray/s Energy range 3 30 kev Quantum efficiency 3 kev: 80 % (calculated) 8 kev: 99 % 15 kev: 55 % Energy resolution 500 ev Adjustable threshold range 2 20 kev Threshold dispersion 50 ev Readout time 2.2 ms Framing rate 30 Hz Point-spread function 1 pixel

Diffraction Geometry Perpendicular and tilted detector geometries Ref. Powder Diffraction: Theory and Practice

Data Analysis Calibration and determination of the Detector Characteristic Determination of the experimental geometry (Beam Center, tilt) Application of the data reduction procedure Application of the diffraction geometry related corrections

Data Reduction using Fit2d Determination of the experimental geometry (Beam Center, tilt) Application of the diffraction geometry related corrections

Data Reduction using Fit2d LaB 6 for sample-detector distance, tilt etc.

Data Reduction using Fit2d LaB 6 for sample-detector distance: Refined Value

Data Reduction using Fit2d

Data Reduction using Fit2d

Data Reduction using Fit2d Polarization Corrections Lorenze correction Absorption correction Polarization correction(fit2d)= (I_h - I_v)/(I_h+I_v) I_h----> horizontal component (direction of X-rays) T_v-----> Vertical component

Data Reduction using Fit2d Relationship between a pixel position and the solid angle covered by it. Angular range covered by the pixel in y and x directions S is the sample or calibration source Solid Angle covered by the pixel For a pixel at arbitrary position P(x,y) Flux at P(x,y) Geometrical corrections to Intensities Flux in photons/s and brightness of S in photons/s per mrad 2

a) b) a) Figure 1. a) 2D image from the Mar345 Image Plate detector set perpendicular to the incident X-ray beam. b) Intensity versus 2θplot obtained from the 2D image after various data reduction procedures as implemented in the program FIT2D. In the inset an expanded region of the plot is shown (λ=0.6519 Å; sample to detector distance=125.22 mm.)

a) b) Figure 2. a) 2D image from the Mar345 Image Plate detector tilted w.r.t. the incident X-ray beam (angle of tilt = 30 deg). b) Intensity versus 2θplot obtained from the 2D image using the program FIT2D. In the inset an expanded region of the plot is shown (λ=0.6519 Å; sample to detector distance=305 mm.)

Figure 3. a) Rietveld refinement data for the GdBaCo 2 O 5.5 system. The plot shows the observed and calculated Intensity versus 2θvalues. The difference plot is also shown. In the inset an expanded region of the plot is shown. b) The crystal structure of GdBaCo 2 O 5.5 from the refined values of lattice and structural parameters obtained from the Rietveld refinement.

Neutron Powder Diffraction (Ti, yi), i= 1,.n T i scattering variable ; 2θ, TOF, Energy y i intensity 03 April 2009 Anthony Arulraj Tel.: 030 8062-2793 Fax: 030 8062-2999 anthony.arulraj@helmholtz-berlin.de

The Rietveld Method The Rietveld method is a structure refinement method that consists of refining a crystal (and/or magnetic) structure by minimizing the weighted squared difference between the observed and calculated pattern. s y ( ) = n wi yi yci i w i = 1 y i 2 y i y ci n = observed intensity at the ith step, = calculated intensity at the ith step, = total number of steps. 03 April 2009 Anthony Arulraj Tel.: 030 8062-2793 Fax: 030 8062-2999 anthony.arulraj@helmholtz-berlin.de

The Rietveld Method ci K K K 2 ( 2Θ ) i ΘK PK A ybi y = s L F ϕ 2 + s Scale factor K miller indices h, k, l F K structure factor L K includes Lorentz factor, multiplicity ϕ profile shape function P K preferred orientation A Absorption correction y bi background intensity 03 April 2009 Anthony Arulraj Tel.: 030 8062-2793 Fax: 030 8062-2999 anthony.arulraj@helmholtz-berlin.de

Structure Factors F f sinθ 2 hkl i B = exp i i i + exp2π λ F [ ( ky lz )] mag = q i p i exp 2πi hx i + i + i [ i( hx + ky lz )] p i magnitude of magnetic cross section p=0.54sf m 10-12 cm S magnetic moment f m magnetic form factor q i magnetic ( interaction ) vector q j = ε ε. K j K j magnetic interaction vector for the jth atom depends on the unit vector (ε) for the scattering vector (h) and the unit vector for the magnetic moment on that atom(kj) 03 April 2009 Anthony Arulraj Tel.: 030 8062-2793 Fax: 030 8062-2999 anthony.arulraj@helmholtz-berlin.de i

Numerical criteria of the fit R wp = i w i i ( y y ) 2 i ci 2 n P Rexp = 2 w i ( y i ) ( ) w i y i i χ 2 = R wp R exp 03 April 2009 Anthony Arulraj Tel.: 030 8062-2793 Fax: 030 8062-2999 anthony.arulraj@helmholtz-berlin.de

Two sets of refinable parameters Profile parameters: Peak positions: A, B, C.; Zero shift 1 2 2 2 2 = A. h + B. k + C. l + D. k. l + E. h. l + F. h. k d 2 Profile: U, V, W etc Structural parameters: Scale factor Atomic coordinates: x i, y i, z i Temperature parameter: B i Components of the magnetic moment vector: K i 03 April 2009 Anthony Arulraj Tel.: 030 8062-2793 Fax: 030 8062-2999 anthony.arulraj@helmholtz-berlin.de

LeBail fit 03 April 2009 Anthony Arulraj Tel.: 030 8062-2793 Fax: 030 8062-2999 anthony.arulraj@helmholtz-berlin.de

Rietveld refinement Z Y X 03 April 2009 Anthony Arulraj Tel.: 030 8062-2793 Fax: 030 8062-2999 anthony.arulraj@helmholtz-berlin.de

THANK YOU