The accurate calibration of all detectors is crucial for the subsequent data
|
|
|
- Gladys Richardson
- 10 years ago
- Views:
Transcription
1 Chapter 4 Calibration The accurate calibration of all detectors is crucial for the subsequent data analysis. The stability of the gain and offset for energy and time calibration of all detectors involved in the measurements has to be monitored. In this chapter the calibration of TAPS, Crystal Barrel and the Tagger are presented in detail. 4.1 TAPS The TAPS detector needs four kinds of calibrations, i.e. pulse-shape calibration, energy calibration, time calibration and trigger threshold calibrations. These calibrations are roughly adjusted using cosmic-ray data obtained before each data taking period. All these calibrations are discussed in the following sections Energy calibration The TAPS energy calibration is done in three stages. First, before data taking, a rough calibration is performed with cosmic muons providing a relative gain adjustment. During the data taking the energy calibration is monitored and the π 0 peak position is used to further improve the energy calibration of all detectors of TAPS. As a last check, the η invariant-mass peak is analyzed for determining the energy dependence of the calibration. 43
2 CHAPTER 4. CALIBRATION 44 Figure 4.1: Example of a cosmic-ray energy spectrum for a single TAPS module. Calibration based on cosmic muons At the beginning of each data taking period cosmic-ray data are taken with the TAPS detector. Since all the TAPS modules have the same shape and orientation, the average energy deposition by minimum-ionizing particles (cosmic muons) is always the same i.e MeV. An example of a raw cosmic-ray spectrum for one of the TAPS detector modules is shown in figure 4.1. In this figure one can clearly identify the pedestal produced by a pulser (see section 3.2.4), the CFD threshold and the minimum ionizing peak. Using the pedestal value, which correspond to E γ = 0 MeV, and the minimum-ionizing peak, which correspond to E γ = 38.5 MeV, the energy offset and gains are calculated using the following formula: gain = 38.5 MeV cosmic peak [ch nr] pedestal [ch nr] (4.1) and offset = gain pedestal [ch nr] (4.2) This calibration is used to monitor the TAPS detector during the measurement. This is done for the narrow- and wide-gate integration.
3 TAPS Calibration based on the π 0 invariant-mass peak Even though the cosmic calibration is good enough to monitor the detector behavior online, for the actual data analysis a more precise energy calibration is needed, which is obtained by using the π 0 invariant-mass peak position. Because of the decay π 0 γγ, the events with at least two neutral hits in the TAPS detector are selected. The 2γ invariant-mass spectrum is produced for all possible pairs of neutral hits. The invariant mass is given by: M γ1 γ 2 = 2E γ1 E γ2 (1 cosθ 1,2 ) (4.3) where, E γ1 and E γ2 are the measured energies of photon 1 and 2, respectively, and θ 1,2 is the opening angle between them. From this invariant-mass spectrum an overall correction factor for the gain of all detectors was determined that shifts the neutral pion peak to the correct mass of MeV. For a more precise fine tuning, an invariant mass for each possible pair of detectors is calculated and that mass is entered into two histograms, corresponding to two detectors of two neutral hits. The exact position of the π 0 peak position is determined by plotting the invariant-mass squared spectrum and fitting the resulting peak with a Gaussian function. Since the pedestals are adjusted accurately during the cosmic calibration and are continuously monitored, only the gain has newly been determined for each detector module. This procedure is repeated iteratively until the 2γ invariant-mass peak converges to the π 0 mass for each of the 528 detector modules. It takes about 3 to 4 iterations. The final result is depicted in figure 4.2 (left) showing the 2γ invariant-mass squared spectrum and (right) the alignment of the different detectors. This calibration is repeated for each day of data taking, in order to control the effect induced by day-night temperature variations and long-term energy shifts. The final result for overall π 0 peak position is shown in figure 4.3 with a resolution of 8 MeV (σ). Calibration based on η π 0 mass After the calibration using the π 0 peak position for each individual detector module is performed, a second calibration point is used for extra fine tuning and correcting possible non-linearities. This point is the invariant mass of the η γγ decay. The η peak is observed consistently 1.5% higher than the true η mass would allow. This effect occurs due to leakage on to detectors outside the cluster
4 CHAPTER 4. CALIBRATION 46 Figure 4.2: The 2γ invariant-mass spectrum for TAPS after the π 0 calibration. Left: the 2γ invariant-mass squared spectrum for one of the TAPS detector modules fitted by a Gaussian function plus a polynomial. The line shown is the correct value for π 0 -mass squared. Right : The π 0 peak position in individual TAPS detector modules. Figure 4.3: The 2γ invariant-mass spectrum for TAPS after the π 0 calibration. Left: The overall π 0 spectrum (all detector modules together). The correct π 0 mass is shown by a line at MeV. Right: The η peak position is at higher mass (dashed curve) than the correct value (vertical line) after the π 0 calibration. After the energy dependent correction the η peak shows the correct mass (solid curve).
5 TAPS Beam time b c Jan e-5 Feb e-5 Jul e-5 Aug e-5 Table 4.1: Energy dependent correction factors for different data taking periods. as stated by [59] and [15]. This non-linearity in the peak position is corrected by measuring the position of two invariant-mass peaks (π 0 and η) and determining the new values for the energy of the photons using the following equation: where, E new = a + b E old + c E 2 old (4.4) c = M η (4.5) b = 1 ( c) (4.6) M η is the η peak position in the 2γ invariant-mass spectrum. The parameter a = 0 because the zero-point of the energy calibration function is determined by the pedestal and may not move. The parameters b and c are fixed by using the π 0 γγ and η γγ invariant-mass peaks and the formula for the invariant mass of two particles (equation 4.3). These correction factors (b and c) have been determined for each data taking period and are shown in table Pulse-shape calibration The BaF 2 scintillators of the TAPS detector have the intrinsic property that the shape of the pulse differs for protons and photons. This feature allows to distinguish between these two particles. The signals from photons and protons have two scintillation light components, narrow and wide. These two components are extracted by integrating the signal twice, one for a narrow time window E short (50 ns) and another for a wide time window E long (2 µs). The integration for the narrow time window contains the information about the fast light component and that for the wide time window contains the information about both the fast and slow components. For protons and photons the ratio of fast and slow component is markedly different. The pulse shape is usually plotted in terms of
6 CHAPTER 4. CALIBRATION 48 Figure 4.4: The pulse-shape spectrum in polar coordinates after calibration. The line shows the cut used to differentiate between photons and protons. the variables R P S and θ P S, defined in polar coordinates as: R P S = E 2 long + E2 short (4.7) θ P S = arctan( E long E short ) (4.8) To identify the protons and photons from pulse-shape spectra, the photon band has to be separated from the proton band. As a first step the cosmic calibrations are used for both wide-gate energy (E long ) and narrow-gate energy (E short ). As E long measures the complete energy and E short measures only part of the energy, a calibration for E short is needed. The narrow-gate energy has to be adjusted such that for photons θ P S = 45. From the above equations, this condition will be true if E long and E short are equal. The pulse-shape spectrum is produced for each detector module. If the photon band deviates from the desired θ P S = 45 line at low values of R P S, the narrow-gate pedestal is adjusted and at high values for R P S, the narrow-gate gain is corrected. The procedure is repeated until the position of the photon band converges to 45. The pulse-shape spectrum after calibration is shown in figure 4.4. The photon band around 45
7 TAPS Figure 4.5: The projection of figure 4.4 on the x-axis for different values of R P S. The line at θ P S = 45 shows the photon peak position. The line left side of 45 is the cut applied to separate protons from the photons.
8 CHAPTER 4. CALIBRATION 50 and proton band left to the photon band are clearly visible. To define a separation between protons and photons, the y-axis in figure 4.4 was divided in several R P S bins. Each bin was then projected onto the x-axis. The projections are shown in figure 4.5. In all these graphs the photon peak is at θ P S = 45 and the proton peak is on the left-side of the photon peak. The photon peak was fitted by a Gaussian function. The cut that separates photons from protons is placed at 3σ away from the mean of the photon peak. The cut is shown by the line next to the line at 45 in figure 4.5. The corresponding cuts applied for different values of R P S are also shown in figure 4.4 by a smooth line. This procedure has been followed for each of the 528 detector modules separately Time calibration The time calibration for the TAPS detector involves the determination of gain and offset for TDC s. A series of pulses of different but known frequencies has been fed to the TDC s. This gives a pattern of sharp peaks in each time spectrum from which the gain is calculated. To determine offsets, the events with two or more neutral hits have been selected by using the cut on π 0 mass (for π 0 calibration refer sec ). The time difference between these two hits has been analyzed. Corresponding spectra have been made for all the possible combinations for each detector module. The offset is adjusted so that the peak in these spectra aligns at zero, which means that photons arrive at these detector modules at the same time. The new constants for the offset have been determined for each day of data taking. Figure 4.6 (left) shows the time difference between two photons after the calibration. The peak is fitted by a Gaussian function. A width (F W HM) of 0.65 ns is observed, while the mean is located at 0 ns. Figure 4.6 (right) shows the alignment of each detector module after the calibration. About 10% of the detectors are found with bad time information. These detectors can not be calibrated because they have either very broad time spectra or more than one peak in the spectra. Such detectors are marked as bad in a defect table. If any of these detectors occurs at the center of the cluster, its TDC information is ignored. Instead, the TDC information from its neighbouring detector (which is a part of the cluster) has been used. If this neighbouring detector is also marked as bad, another neighbouring detector has been checked for a valid TDC information. This check has been carried out until a good TDC is found in a cluster. During the measurement there is the possibility that the coincident signals might cross the threshold at different times if their amplitudes differ. Because
9 TAPS Figure 4.6: The difference in the timing signals between two photons in TAPS, after calibration. Left: All detectors together. Right: For individual detector modules. Beam time a b c Jan e e-5 Feb e e-6 Jul e e-6 Aug e e-6 Table 4.2: Time-walk correction factors for different data taking periods. of this effect a small deviation in the time is seen for photons of low energies; this is called the time-walk. To take care of this time-walk a correction function is determined from histograms of the photon-photon time in TAPS versus the photon energy. These histograms are fitted with the energy-dependent formula: E start = b 2c (4.9) t corr = a b2 4c fore E start (4.10) t corr = a + be + ce 2 fore E start (4.11) This calibration is performed as an overall correction for all modules and is done for every data taking period separately. In table 4.2, the time-walk correction factors are given for different data taking periods.
10 CHAPTER 4. CALIBRATION 52 Figure 4.7: TAPS LED threshold determination. Left: Example of an energy spectrum without any conditions is superimposed by the energy spectrum after the LED threshold has been applied. Right: The ratio of the two spectra from the left side of the graph. The vertical line shown in this picture is a cut used to determine the LED threshold. 4.2 LED threshold calibration The LED s are used to discriminate the events below a certain energy. They decide whether the event will be recorded or not. Therefore a proper LED calibration has to be done at the beginning of data taking. This calibration is based on cosmic rays. Three measurements were taken with three different threshold settings (mv) of LED s. These three points in combination with the cosmic calibration give the calibration function for the LED thresholds. It determines the correlation between the threshold voltage setting (mv) and the threshold energy (MeV) of the LED module. The LED-high and LED-low thresholds have been applied to each detector unit. During the offline analysis more precise LED thresholds have been determined. For this calibration, the energy spectrum without LED thresholds and with LED thresholds has been produced for each TAPS detector module. The ratio of both spectra indicates the threshold value (figure 4.7). The thresholds are determined using the point where the ratio = 0.9. This procedure is applied for both LED values, high and low. Since during the data taking only one type of LED s are used in the bit pattern, only one type of LED value is determined at one time. This procedure is repeated for each beam time, once to determine the LED-high and once for the LED-low thresholds for each detector module.
11 CRYSTAL BARREL Figure 4.8: The 2γ invariant-mass squared spectrum for one of the Crystal Barrel modules at different stpdf of the iteration procedure for gain adjustment. 4.3 Crystal Barrel The procedure to calibrate the Crystal Barrel is very similar to the procedure to calibrate TAPS. The main difference is that the cosmic calibration for the Crystal Barrel is not practical. This is because the Crystal Barrel modules have different sizes and orientations and the energy deposited in each module is not the same. Since QDC s of the Crystal Barrel have two ranges, two types of calibration have to be done. The calibration for the low-energy part has been done using the π 0 calibration method as discussed to calibrate TAPS modules. Because the pedestals are determined and subtracted online, only the gains need to be determined. For the calibration of the high-energy range a certain amount of laser light corresponding to different known energies has been injected into each crystal. Then the gains have been calculated for each crystal. Similar to TAPS, for the final analysis a more precise energy calibration has been done based on the π 0 invariant mass. The π 0 invariant mass has been studied for each crystal module. The π 0 peak position of a cluster of modules has been adjusted to MeV by correcting the gain of the individual module. This procedure is repeated until the module reaches a stable value. The position of the π 0 peak after different iterations is shown in figure 4.8. In this picture the 2γ invariant-mass squared is plotted. More details on the Crystal Barrel calibration can be found in [60].
12 CHAPTER 4. CALIBRATION 54 4 (ns) Time Taps-Tagger Tagger fiber Figure 4.9: TAPS-Tagger time difference for all Tagger fibers. 4.4 Tagger The energy of the photons created by the bremsstrahlung process was measured by the tagger. The electron beam deflected by the dipole magnet hits scintillating fibers in the tagger. Two type of calibrations are necessary for the tagger. One is an energy calibration in which the photon energy corresponding to the position of each fiber is determined. The other is a time calibration. The time information from the tagger is very useful to reduce the random background Time Calibration The TDC s of each scintillating fiber are calibrated using the events with at least one neutral hit occurring in TAPS. Prior to this calibration the TAPS TDC s are calibrated. The time difference between each fiber and TAPS is plotted. The new offset for the fiber TDC is determined so that the prompt peak shifts to zero. In figure (4.9) the TAPS-Tagger time difference for each tagger fiber is shown. The time resolution for all fibers together is found to be 2 ns (FWHM), which is worse than the TAPS resolution.
13 4.4.2 Energy Calibration The energy of the photon is determined by tracking the position of the corresponding electron on the fiber. The radius of the circular path traveled by the electron is given by: ρ = p Bq (4.12) where, ρ = bending radius, p = electron momentum, B = magnetic field, q= charge. From this formula the radius is directly proportional to the momentum of the electron if the magnetic field and charge are constant. Since before the bremsstrahlung process all the electrons have the same energy, it is easy to calculate the energy of the photon. A fourth order polynomial function was calculated by using the measured field map of the bending magnet and the known positions of the fibers. The electron beam of 3.2 GeV is used to calculate the corresponding energy of each fiber. The check of this calibration was carried out by keeping the magnetic field constant and changing the electron beam energy. Such a procedure takes a lot of time, since it involves the fine tuning of the beam at the accelerator. Therefore the measurements have been taken only at four points for the magnetic field for a beam energy of 3.2 GeV. The four points are shown in figure A discrepancy up to 30 MeV for lower photon beam energies and a few MeV for higher photon beam energies has been observed. So one more calibration procedure was carried out. It makes use of the polarization of the beam. The linearly polarized beam was obtained by replacing the amorphous radiator by a crystalline radiator. When the beam is properly aligned and the angle of the crystal is known, the exact energy of the coherent peak can be calculated [61]. The second order polynomial is calculated from the last two methods. This polynomial is applied to the fourth-order polynomial calculated from the first method. More details about the Tagger calibration can be found in [62].
14 CHAPTER 4. CALIBRATION Energy value (Mev) Fiber index Figure 4.10: Tagger energy correction.
15 TAGGER
16
Calorimetry in particle physics experiments
Calorimetry in particle physics experiments Unit n. 8 Calibration techniques Roberta Arcidiacono Lecture overview Introduction Hardware Calibration Test Beam Calibration In-situ Calibration (EM calorimeters)
Electron-Muon Ranger (EMR)
Electron-Muon Ranger (EMR) Digitization and Reconstruction François Drielsma Ruslan Asfandiyarov University of Geneva On Behalf of the EMR Group 38 th MICE Collaboration Meeting February 23, 2014 Electron-Muon
Measurement of Muon Lifetime and Mass Using Cosmic Ray Showers
Measurement of Muon Lifetime and Mass Using Cosmic Ray Showers Angela Hansen Physics 4052 School of Physics and Astronomy, University of Minnesota May 4, 2001 Abstract In this experiment, we used a scintillation
CMS Tracking Performance Results from early LHC Running
CMS Tracking Performance Results from early LHC Running CMS PAPER TRK-10-001 L. Spiegel, K. Stenson, M. Swartz 1 First Collisions Tracking Paper Provide description of tracker, tracking algorithm, and
Tutorial 4.6 Gamma Spectrum Analysis
Tutorial 4.6 Gamma Spectrum Analysis Slide 1. Gamma Spectrum Analysis In this module, we will apply the concepts that were discussed in Tutorial 4.1, Interactions of Radiation with Matter. Slide 2. Learning
Electron-Muon Ranger (EMR)
Electron-Muon Ranger (EMR) Ruslan Asfandiyarov MICE Video Conference April 11, 2013 Construction Construction quarter of the detector completed (12 planes) every plane tested (LED / Camera / image analysis)
AMS DAQ, TRD DSP Software
AMS DAQ, TRD DSP Software and other Topics Overview Arbeitstreffen, Aachen, Jul. 2011 Andreas Sabellek IEKP - KIT Campus South Supported by the Carl-Zeiss-Foundation AMS on ISS Realtime position: e.g.
Copyright 2007 Casa Software Ltd. www.casaxps.com. ToF Mass Calibration
ToF Mass Calibration Essentially, the relationship between the mass m of an ion and the time taken for the ion of a given charge to travel a fixed distance is quadratic in the flight time t. For an ideal
ATLAS Test Beam Analysis in Stockholm: An Overview
ATLAS Test Beam Analysis in Stockholm: An Overview Elin Bergeås, Stockholm University Stand-alone test beam 2003 and before - test beam targeted at TileCal modules only Combined test beam 2004 - test beam
Energy Deposition in MICE Absorbers and Coils
in MICE Absorbers and Coils November 2, 2003 Video Conference Page 1 An Application for G4Mice We would like to estimate how much energy is deposited in magnet coils and the hydrogen absorber. Most of
Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission
Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission MAVEN Science Community Workshop December 2, 2012 Particles and Fields Package Solar Energetic Particle Instrument (SEP) Davin Larson and the SEP
Introduction to Geiger Counters
Introduction to Geiger Counters A Geiger counter (Geiger-Muller tube) is a device used for the detection and measurement of all types of radiation: alpha, beta and gamma radiation. Basically it consists
Fundamentals of modern UV-visible spectroscopy. Presentation Materials
Fundamentals of modern UV-visible spectroscopy Presentation Materials The Electromagnetic Spectrum E = hν ν = c / λ 1 Electronic Transitions in Formaldehyde 2 Electronic Transitions and Spectra of Atoms
Experiment 10. Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado
1 Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado Introduction Some radioactive isotopes formed billions of years ago have half- lives so long that they are
07 - Cherenkov and transition radiation detectors
07 - Cherenkov and transition radiation detectors Jaroslav Adam Czech Technical University in Prague Version 1.0 Jaroslav Adam (CTU, Prague) DPD_07, Cherenkov and transition radiation Version 1.0 1 / 30
Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software By R.Redus, Chief Scientist, Amptek Inc, 2008.
Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software By R.Redus, Chief Scientist, Amptek Inc, 2008. X-Ray Fluorescence (XRF) is a very simple analytical technique: X-rays excite atoms
Information about the T9 beam line and experimental facilities
Information about the T9 beam line and experimental facilities The incoming proton beam from the PS accelerator impinges on the North target and thus produces the particles for the T9 beam line. The collisions
Evaluation Tools for the Performance of a NESTOR Test Detector
Evaluation Tools for the Performance of a NESTOR Test Detector G. Bourlis, A. Leisos, S. E. Tzamarias and A. Tsirigotis Particle and Astroparticle Physics Group School of Science and Technology Hellenic
Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)
Low energy ion scattering study of 4 on Cu(1) Chapter 8. Low energy ion scattering study of 4 on Cu(1) 8.1. Introduction For a better understanding of the reconstructed 4 surfaces one would like to know
The OPERA Emulsions. Jan Lenkeit. Hamburg Student Seminar, 12 June 2008. Institut für Experimentalphysik Forschungsgruppe Neutrinophysik
The OPERA Emulsions Jan Lenkeit Institut für Experimentalphysik Forschungsgruppe Neutrinophysik Hamburg Student Seminar, 12 June 2008 1/43 Outline The OPERA experiment Nuclear emulsions The OPERA emulsions
Physics 111 Homework Solutions Week #9 - Tuesday
Physics 111 Homework Solutions Week #9 - Tuesday Friday, February 25, 2011 Chapter 22 Questions - None Multiple-Choice 223 A 224 C 225 B 226 B 227 B 229 D Problems 227 In this double slit experiment we
13C NMR Spectroscopy
13 C NMR Spectroscopy Introduction Nuclear magnetic resonance spectroscopy (NMR) is the most powerful tool available for structural determination. A nucleus with an odd number of protons, an odd number
Interstellar Cosmic-Ray Spectrum from Gamma Rays and Synchrotron
Interstellar Cosmic-Ray Spectrum from Gamma Rays and Synchrotron Chuck Naval Research Laboratory, Washington, DC [email protected] Andy Strong Max-Planck-Institut für extraterrestrische Physik,
Cross section, Flux, Luminosity, Scattering Rates
Cross section, Flux, Luminosity, Scattering Rates Table of Contents Paul Avery (Andrey Korytov) Sep. 9, 013 1 Introduction... 1 Cross section, flux and scattering... 1 3 Scattering length λ and λ ρ...
Module 13 : Measurements on Fiber Optic Systems
Module 13 : Measurements on Fiber Optic Systems Lecture : Measurements on Fiber Optic Systems Objectives In this lecture you will learn the following Measurements on Fiber Optic Systems Attenuation (Loss)
Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies
Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies (Ci), where 1 Ci = 3.7x10 10 disintegrations per second.
Functional Data Analysis of MALDI TOF Protein Spectra
Functional Data Analysis of MALDI TOF Protein Spectra Dean Billheimer [email protected]. Department of Biostatistics Vanderbilt University Vanderbilt Ingram Cancer Center FDA for MALDI TOF
How To Use An Ionsonic Microscope
Sample Analysis Design Element2 - Basic Software Concepts Scan Modes Magnetic Scan (BScan): the electric field is kept constant and the magnetic field is varied as a function of time the BScan is suitable
CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE
CELL CYCLE BASICS Analysis of a population of cells replication state can be achieved by fluorescence labeling of the nuclei of cells in suspension and then analyzing the fluorescence properties of each
MSc in Autonomous Robotics Engineering University of York
MSc in Autonomous Robotics Engineering University of York Practical Robotics Module 2015 A Mobile Robot Navigation System: Labs 1a, 1b, 2a, 2b. Associated lectures: Lecture 1 and lecture 2, given by Nick
AP Physics 1 and 2 Lab Investigations
AP Physics 1 and 2 Lab Investigations Student Guide to Data Analysis New York, NY. College Board, Advanced Placement, Advanced Placement Program, AP, AP Central, and the acorn logo are registered trademarks
PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS
PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS 1. Photons 2. Photoelectric Effect 3. Experimental Set-up to study Photoelectric Effect 4. Effect of Intensity, Frequency, Potential on P.E.
A Guide to Detectors Particle Physics Masterclass. M. van Dijk
A Guide to Particle Physics Masterclass M. van Dijk 16/04/2013 How detectors work Scintillation Ionization Particle identification Tracking Calorimetry Data Analysis W & Z bosons 2 Reconstructing collisions
High Energy Physics. Lecture 4 More kinematics and a picture show of particle collisions
High Energy Physics Lecture 4 More kinematics and a picture show of particle collisions 1 Recall from the previous lecture: the momentum of the scattered Particle in an elastic collision is given by p
Solid State Detectors = Semi-Conductor based Detectors
Solid State Detectors = Semi-Conductor based Detectors Materials and their properties Energy bands and electronic structure Charge transport and conductivity Boundaries: the p-n junction Charge collection
Electrical Resonance
Electrical Resonance (R-L-C series circuit) APPARATUS 1. R-L-C Circuit board 2. Signal generator 3. Oscilloscope Tektronix TDS1002 with two sets of leads (see Introduction to the Oscilloscope ) INTRODUCTION
Testing thermo-acoustic sound generation in water with proton and laser beams
International ARENA Workshop DESY, Zeuthen 17th 19th of May 25 Testing thermo-acoustic sound generation in water with proton and laser beams Kay Graf Universität Erlangen-Nürnberg Physikalisches Institut
Clock Jitter Definitions and Measurement Methods
January 2014 Clock Jitter Definitions and Measurement Methods 1 Introduction Jitter is the timing variations of a set of signal edges from their ideal values. Jitters in clock signals are typically caused
ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1
WHAT IS AN FFT SPECTRUM ANALYZER? ANALYZER BASICS The SR760 FFT Spectrum Analyzer takes a time varying input signal, like you would see on an oscilloscope trace, and computes its frequency spectrum. Fourier's
MICE detectors and first results. M. Bonesini Sezione INFN Milano Bicocca
MICE detectors and first results M. Bonesini Sezione INFN Milano Bicocca I will speak of the installed beamline PID detectors (TOFes, CKOVs, KL) and only shortly of EMR (to be built)/ the trackers (tested
ISTITUTO NAZIONALE DI FISICA NUCLEARE
ISTITUTO NAZIONALE DI FISICA NUCLEARE Sezione di Catania INFN/TC-11/02 February 28, 2011 PRELIMINARY TESTS OF A SCINTILLATOR-BASED MINI-STATION FOR EXTENSIVE AIR SHOWERS MEASUREMENTS S.Aiola 1, P. La Rocca
Application Note Noise Frequently Asked Questions
: What is? is a random signal inherent in all physical components. It directly limits the detection and processing of all information. The common form of noise is white Gaussian due to the many random
Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9
Module 9 This module presents information on what X-rays are and how they are produced. Introduction Module 9, Page 2 X-rays are a type of electromagnetic radiation. Other types of electromagnetic radiation
High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules
High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules Abstract J.L. Crozier, E.E. van Dyk, F.J. Vorster Nelson Mandela Metropolitan University Electroluminescence (EL) is a useful
PUMPED Nd:YAG LASER. Last Revision: August 21, 2007
PUMPED Nd:YAG LASER Last Revision: August 21, 2007 QUESTION TO BE INVESTIGATED: How can an efficient atomic transition laser be constructed and characterized? INTRODUCTION: This lab exercise will allow
POSSIBL-E EXPERIMENTS ON THE 200-GeV ACCELERATOR. A. D. Krisch University of Michigan. R. Serber Columbia University.
FN-68 POSSIBL-E EXPERIMENTS ON THE 200-GeV ACCELERATOR A. D. Krisch University of Michigan R. Serber Columbia University August 23, 1967 We will describe a number of experiments that might be dcne on.,he
The data acquisition system of the XMASS experiment
The data acquisition system of the XMASS experiment Katsuki Hiraide 1,2, for the XMASS Collaboration 1 Kamioka Observatory, Institute for Cosmic Ray Research, the University of Tokyo, Higashi-Mozumi, Kamioka,
EXPERIMENTAL ERROR AND DATA ANALYSIS
EXPERIMENTAL ERROR AND DATA ANALYSIS 1. INTRODUCTION: Laboratory experiments involve taking measurements of physical quantities. No measurement of any physical quantity is ever perfectly accurate, except
Does Quantum Mechanics Make Sense? Size
Does Quantum Mechanics Make Sense? Some relatively simple concepts show why the answer is yes. Size Classical Mechanics Quantum Mechanics Relative Absolute What does relative vs. absolute size mean? Why
T(CR)3IC Testbed for Coherent Radio Cherenkov Radiation from Cosmic-Ray Induced Cascades
T(CR)3IC Testbed for Coherent Radio Cherenkov Radiation from Cosmic-Ray Induced Cascades R. Milinčić1, P. Gorham1, C. Hebert1, S. Matsuno1, P. Miočinović1, M. Rosen1, D. Saltzberg2, G. Varner1 1 University
x 1 ' = x 1 vt 1 x 1 ' = 4.0 m t 1 = 1.0 s x 2 vt 2 ' = 4.0 m t 2 ' = x 2 = 3.0 s x 1 = x 2 x 1 ' + vt 1 ' + vt 2 v (t 1 t 2 ) = x 2 ' x 1 ' = x 2
Physics 2220 Module 16 Homework 01. A firecracker explodes in reference frame S at t 1 1.0 seconds. A second firecracker explodes at the same position at t 2 3.0 seconds. In reference frame S', which moves
Industry Environment and Concepts for Forecasting 1
Table of Contents Industry Environment and Concepts for Forecasting 1 Forecasting Methods Overview...2 Multilevel Forecasting...3 Demand Forecasting...4 Integrating Information...5 Simplifying the Forecast...6
π 0 γγ calibration Savrina Daria, ITEP, Moscow SINP MSU, Moscow Victor Egorychev, ITEP, Moscow Ivan Belyaev
π 0 γγ calibration Savrina Daria, ITEP, Moscow SINP MSU, Moscow Ivan Belyaev Victor Egorychev, ITEP, Moscow Loose cuts for π 0 selection One of the ways to improve the calibration procedure is to increase
Symmetric Stretch: allows molecule to move through space
BACKGROUND INFORMATION Infrared Spectroscopy Before introducing the subject of IR spectroscopy, we must first review some aspects of the electromagnetic spectrum. The electromagnetic spectrum is composed
Synthetic Sensing: Proximity / Distance Sensors
Synthetic Sensing: Proximity / Distance Sensors MediaRobotics Lab, February 2010 Proximity detection is dependent on the object of interest. One size does not fit all For non-contact distance measurement,
AS COMPETITION PAPER 2008
AS COMPETITION PAPER 28 Name School Town & County Total Mark/5 Time Allowed: One hour Attempt as many questions as you can. Write your answers on this question paper. Marks allocated for each question
ORTEC. Fast-Timing Discriminator Introduction. Choosing the Right Timing Discriminator for the Application. Counting
Choosing the Right Timing Discriminator for the Application Fast timing discriminators are useful in two different applications: a) counting narrow pulses at very high counting rates, and b) precisely
Uses of Derivative Spectroscopy
Uses of Derivative Spectroscopy Application Note UV-Visible Spectroscopy Anthony J. Owen Derivative spectroscopy uses first or higher derivatives of absorbance with respect to wavelength for qualitative
ENERGY LOSS OF ALPHA PARTICLES IN GASES
Vilnius University Faculty of Physics Department of Solid State Electronics Laboratory of Applied Nuclear Physics Experiment No. ENERGY LOSS OF ALPHA PARTICLES IN GASES by Andrius Poškus (e-mail: [email protected])
THE STATISTICAL TREATMENT OF EXPERIMENTAL DATA 1
THE STATISTICAL TREATMET OF EXPERIMETAL DATA Introduction The subject of statistical data analysis is regarded as crucial by most scientists, since error-free measurement is impossible in virtually all
A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION
35'th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting San Diego, December 2-4, 2003 A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION Józef Kalisz and Ryszard Szplet
CHAPTER 6 PHOTON COUNTING
CHAPTER 6 PHOTON COUNTING 1) 2) 4) - 12) Photon counting is an effective technique used to detect very-lowlevel-light such as Raman spectroscopy, fluorescence analysis, and chemical or biological luminescence
E190Q Lecture 5 Autonomous Robot Navigation
E190Q Lecture 5 Autonomous Robot Navigation Instructor: Chris Clark Semester: Spring 2014 1 Figures courtesy of Siegwart & Nourbakhsh Control Structures Planning Based Control Prior Knowledge Operator
Introduction to X-Ray Powder Diffraction Data Analysis
Introduction to X-Ray Powder Diffraction Data Analysis Center for Materials Science and Engineering at MIT http://prism.mit.edu/xray An X-ray diffraction pattern is a plot of the intensity of X-rays scattered
Charged Particle in a Magnetic Field
Charged Particle in a Magnetic Field Consider a particle moving in an external magnetic field with its velocity perpendicular to the field The force is always directed toward the center of the circular
Timing Errors and Jitter
Timing Errors and Jitter Background Mike Story In a sampled (digital) system, samples have to be accurate in level and time. The digital system uses the two bits of information the signal was this big
World-first Proton Pencil Beam Scanning System with FDA Clearance
Hitachi Review Vol. 58 (29), No.5 225 World-first Proton Pencil Beam Scanning System with FDA Clearance Completion of Proton Therapy System for MDACC Koji Matsuda Hiroyuki Itami Daishun Chiba Kazuyoshi
THE DØ Luminosity Monitor (LM) consists of two array of
FERMILAB-CONF-6-469-E Radiation Damage to Scintillator in the DØ Luminosity Monitor Brendan Casey, Kayle DeVaughan, Yuji Enari, Richard Partridge, and Sahal Yacoob Abstract We report the result of evaluating
Cathode Ray Tube. Introduction. Functional principle
Introduction The Cathode Ray Tube or Braun s Tube was invented by the German physicist Karl Ferdinand Braun in 897 and is today used in computer monitors, TV sets and oscilloscope tubes. The path of the
Chapter 6: The Information Function 129. CHAPTER 7 Test Calibration
Chapter 6: The Information Function 129 CHAPTER 7 Test Calibration 130 Chapter 7: Test Calibration CHAPTER 7 Test Calibration For didactic purposes, all of the preceding chapters have assumed that the
electron does not become part of the compound; one electron goes in but two electrons come out.
Characterization Techniques for Organic Compounds. When we run a reaction in the laboratory or when we isolate a compound from nature, one of our first tasks is to identify the compound that we have obtained.
Modern Construction Materials Prof. Ravindra Gettu Department of Civil Engineering Indian Institute of Technology, Madras
Modern Construction Materials Prof. Ravindra Gettu Department of Civil Engineering Indian Institute of Technology, Madras Module - 2 Lecture - 2 Part 2 of 2 Review of Atomic Bonding II We will continue
How To Understand Light And Color
PRACTICE EXAM IV P202 SPRING 2004 1. In two separate double slit experiments, an interference pattern is observed on a screen. In the first experiment, violet light (λ = 754 nm) is used and a second-order
The interaction of Cu(100)-Fe surfaces with oxygen studied with photoelectron spectroscopy. I
5 The interaction of Cu(100)-Fe surfaces with oxygen studied with photoelectron spectroscopy. I Mg Kα excited photoemission. Abstract The oxidation of Cu(100)-Fe surfaces was studied using XPS. Surfaces
The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT
The Effect of Network Cabling on Bit Error Rate Performance By Paul Kish NORDX/CDT Table of Contents Introduction... 2 Probability of Causing Errors... 3 Noise Sources Contributing to Errors... 4 Bit Error
AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE
AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE Thank you for purchasing your Amplified High Speed Fiber Photodetector. This user s guide will help answer any questions you may have regarding the
Three-dimensional figure showing the operation of the CRT. The dotted line shows the path traversed by an example electron.
Physics 241 Lab: Cathode Ray Tube http://bohr.physics.arizona.edu/~leone/ua/ua_spring_2010/phys241lab.html NAME: Section 1: 1.1. A cathode ray tube works by boiling electrons off a cathode heating element
An option for the SHiP Muon Detector: Scintillator bars with WLS fibers and SiPMs readout
An option for the SHiP Muon Detector: Scintillator bars with WLS fibers and SiPMs readout M. Anelli, W. Baldini, P. Ciambrone, M. Dallavalle, F. Fabbri, G. Lanfranchi, A. Montanari INFN-LNF, INFN-Ferrara,
Extended Resolution TOA Measurement in an IFM Receiver
Extended Resolution TOA Measurement in an IFM Receiver Time of arrival (TOA) measurements define precisely when an RF signal is received, necessary in the identification of type and mode of RF and radar
Power Electronics. Prof. K. Gopakumar. Centre for Electronics Design and Technology. Indian Institute of Science, Bangalore.
Power Electronics Prof. K. Gopakumar Centre for Electronics Design and Technology Indian Institute of Science, Bangalore Lecture - 1 Electric Drive Today, we will start with the topic on industrial drive
Experiment 5. Lasers and laser mode structure
Northeastern University, PHYS5318 Spring 2014, 1 1. Introduction Experiment 5. Lasers and laser mode structure The laser is a very important optical tool that has found widespread use in science and industry,
KNOWLEDGE BASE ARTICLE Zero Voltage Transmission (ZVT) Technology. Basics of the GPZ 7000 Technology: Zero Voltage Transmission (ZVT)
KNOWLEDGE BASE ARTICLE Zero Voltage Transmission (ZVT) Technology Basics of the GPZ 7000 Technology: Zero Voltage Transmission (ZVT) By Bruce Candy Basic Metal Detection Principles 1 2 3 4 Simplified representation
1) Write the following as an algebraic expression using x as the variable: Triple a number subtracted from the number
1) Write the following as an algebraic expression using x as the variable: Triple a number subtracted from the number A. 3(x - x) B. x 3 x C. 3x - x D. x - 3x 2) Write the following as an algebraic expression
Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics
Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics PART I Geiger Tube: Optimal Operating Voltage and Resolving Time Objective: To become acquainted with the operation and characteristics
Experiment #1, Analyze Data using Excel, Calculator and Graphs.
Physics 182 - Fall 2014 - Experiment #1 1 Experiment #1, Analyze Data using Excel, Calculator and Graphs. 1 Purpose (5 Points, Including Title. Points apply to your lab report.) Before we start measuring
8.2 Elastic Strain Energy
Section 8. 8. Elastic Strain Energy The strain energy stored in an elastic material upon deformation is calculated below for a number of different geometries and loading conditions. These expressions for
arxiv:astro-ph/0509450 v1 15 Sep 2005
arxiv:astro-ph/0509450 v1 15 Sep 2005 TESTING THERMO-ACOUSTIC SOUND GENERATION IN WATER WITH PROTON AND LASER BEAMS K. GRAF, G. ANTON, J. HÖSSL, A. KAPPES, T. KARG, U. KATZ, R. LAHMANN, C. NAUMANN, K.
Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note
Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range Application Note Table of Contents 3 3 3 4 4 4 5 6 7 7 7 7 9 10 10 11 11 12 12 13 13 14 15 1. Introduction What is dynamic range?
Objectives. Electric Current
Objectives Define electrical current as a rate. Describe what is measured by ammeters and voltmeters. Explain how to connect an ammeter and a voltmeter in an electrical circuit. Explain why electrons travel
INTERFERENCE OF SOUND WAVES
2011 Interference - 1 INTERFERENCE OF SOUND WAVES The objectives of this experiment are: To measure the wavelength, frequency, and propagation speed of ultrasonic sound waves. To observe interference phenomena
Pulsed Fourier Transform NMR The rotating frame of reference. The NMR Experiment. The Rotating Frame of Reference.
Pulsed Fourier Transform NR The rotating frame of reference The NR Eperiment. The Rotating Frame of Reference. When we perform a NR eperiment we disturb the equilibrium state of the sstem and then monitor
Ionosphere Properties and Behaviors - Part 2 By Marcel H. De Canck, ON5AU
Ionosphere Properties and Behaviors - Part 2 By Marcel H. De Canck, ON5AU I n the previous issue I explained that gyrofrequency depends on the earth s magnetic field and mentioned that this magnetic field
Grazing incidence wavefront sensing and verification of X-ray optics performance
Grazing incidence wavefront sensing and verification of X-ray optics performance Timo T. Saha, Scott Rohrbach, and William W. Zhang, NASA Goddard Space Flight Center, Greenbelt, Md 20771 Evaluation of
1. Units of a magnetic field might be: A. C m/s B. C s/m C. C/kg D. kg/c s E. N/C m ans: D
Chapter 28: MAGNETIC FIELDS 1 Units of a magnetic field might be: A C m/s B C s/m C C/kg D kg/c s E N/C m 2 In the formula F = q v B: A F must be perpendicular to v but not necessarily to B B F must be
A METHOD OF CALIBRATING HELMHOLTZ COILS FOR THE MEASUREMENT OF PERMANENT MAGNETS
A METHOD OF CALIBRATING HELMHOLTZ COILS FOR THE MEASUREMENT OF PERMANENT MAGNETS Joseph J. Stupak Jr, Oersted Technology Tualatin, Oregon (reprinted from IMCSD 24th Annual Proceedings 1995) ABSTRACT The