Schneider Electric. TeSys Vacuum Contactors. June. Building a New Electric World



Similar documents
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

RM4TG20 three-phase network control relay RM4-T - range V

Type: DILM32 10(24V50HZ) Article No.:

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM9 10(24VDC) Article No.:

D-Line Contactors, Overload Relays and Accessories

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Catalog. Modular DIN rail components Installation contactors

Electronic overload relay EF19 and EF45

Technical catalogue. Modular DIN rail components Installation contactors

Safety automation solutions

Electronic overload relay EF65, EF96 and EF146

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Manual motor starter MS116

Safety detection solutions

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Pendant control stations 6

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

PSR The compact range Description

49 Series - Relay interface modules A. Features

R.C.C.B. s two-pole LEXIC

RY2 miniature industrial relays

Manual Motor Starter MS 116 up to 16 A Technical Data

Catalog January. Heavy industrial power applications Motor contactors and starters

Technicaldata General

Safety dialogue solutions

Pluggable interface relays CR-P Pcb relays

48 SERIES Relay interface modules 10 A

Relés e Contatores de Estado Sólido SIRIUS

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

E-STOP relays, safety gate monitors

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

Plug and Socket Devices CES 63 A Series 8579

Contact expander modules

Preventa Machine Safety Products

Switching Devices Contactors and Contactor Assemblies Special Applications

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

more than a breaker it s a breakthrough Compact NSX

3/2-way Solenoid Valve, direct-acting, NC or NO

Bimetallic Overload Relay Specifications

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Contact expansion modules

ELECTROMAGNETIC DISC BRAKES

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

FUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue SOCOMEC. Fuse combination switches

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Bulletin 150 SMC Flex Smart Motor Controller Specifications

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Series 8146/5-V37 and Series 8150/5-V37

CATALOG #250

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Three-phase monitoring relay CM-PFE

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

38 Series - Relay interface modules A

Telemecanique Zelio Relay complementary and easy to assemble

E-STOP relays, safety gate monitors

PNOZsigma - Base units

E-STOP relays, safety gate monitors

Cable Plug acc. to DIN EN , Form A

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD

Softstarters Type PSR

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

38 Series - Relay interface modules A

Thermal-Magnetic Circuit Breaker M1-..

E-STOP relays, safety gate monitors

Electric Rotary Actuator - On/Off or programmable control actuator

Plug and Socket Devices SolConeX 16 A Series 8570

Quick Connect. quick - simple - efficient.

Energy Management Energy Meter Type EM23 DIN

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Electro-pneumatic control valves

mecotron Safety relay ESTOP-2 For emergency stop monitoring

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

Safety Relays ESM/ESM-F

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

CQM1-SF200/CS1W-SF200

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

SURGE PROTECTIVE DEVICES

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

E-STOP relays, safety gate monitors

Transcription:

TeSys Vacuum Contactors June 2002 Building a New Electric World

Selection guide, characteristics Contactors 5 Selection guide Contactor size LC1-V160 LC1-V320 LC1-V610 For utilisation category AC-3 Maximum operational current in AC-3 A 160 320 610 230 V kw 45 90 160 400 V kw 75 160 300 (standard power ratings 525 V kw 110 220 400 of motors) 690 V kw 150 280 560 1000 V kw 200 400 800 1500 V kw 280 600 930 For 3-phase motors conforming to CSA standards 200 V hp 50 100 150 240 V hp 60 125 200 (standard power ratings of 380 V hp 100 200 300 3-phase CSA motors) 480 V hp 125 250 400 600 V hp 150 300 500 800 V hp 200 400 700 1000 V hp 250 500 1000 1500 V hp 400 800 1300 For switching 3-phase capacitors 240 V kvar 47 94 176 480 V kvar 95 190 356 600 V kvar 100 200 400 1500 V kvar 250 500 1000 For switching the primaries of 3-phase transformers (LV/LV) Environment characteristics 208 V kva 20 41 81 240 V kva 23 47 94 480 V kva 47 94 188 600 V kva 59 117 234 Type LC1-V160 LC1-V320 LC1-V610 Shock resistance (1/2 sine wave = 11 ms) Contacts closed 10 gn 10 gn 10 gn Contacts open 10 gn 10 gn 10 gn Vibration resistance 10 500 Hz 2 gn 2 gn 2 gn Operating altitude Above sea level Maximum m 3600 3600 3600 Below sea level Minimum m 2500 4500 4500 Ambient air temperature around the device Storage C - 40 + 80-40 + 80-40 + 80 For operation C - 5 + 55-5 + 55-5 + 55 at 0.8 1.1 Uc Permissible for operation at Uc C - 10 + 75-10 + 75-10 + 75 Degree of protection Conforming to IEC 529 IP 00 IP 00 IP 00 Operating position Any Any Any Cabling Cable c.s.a. mm 2 70 185 2 x 185 Key for hex. screws mm Allen 4 20 20 Tightening torque N.m 14 39 39 Control circuit characteristics Rated insulation voltage (Ui) To earth V 2000 2000 2000 Consumption Inrush VA 300 600 1700 Sealed VA 30 20 28 Permissible control circuit voltage 0.8 1.1 Uc 0.8 1.1 Uc 0.8 1.1 Uc 1

Characteristics (continued) Contactors 5 Type LC1-V160 LC1-V320 LC1-V610 Main pole characteristics Rated insulation voltage (Ui) V 1500 1500 1500 Rated impulse withstand voltage (Uimp) kv 8 8 8 Conformity to standards EN 60947-4-1 - IEC 947-4-1 Approvals CSA Conventional thermal current (Ith) A 160 320 630 voltage (Ie) y 40 C AC-1 A 160 320 630 y 55 C AC-3 A 160 320 610 y 55 C AC-4 A 130 270 540 Electrical durability in number of operating cycles AC-1 1 000 000 700 000 300 000 AC-3 1 000 000 700 000 300 000 AC-4 180 000 90 000 60 000 Mechanical durability In millions of operating cycles 5 2.5 2 Maximum operating rate in operating cycles per hour Maximum making capacity (Irms) Maximum breaking capacity (Irms) Permissible short time rating Mechanical 1200 1200 1200 AC-1 900 900 900 AC-3 900 900 900 AC-4 450 450 450 Ue = 1500 V To IEC 947 A 1900 3800 7300 Ue = 1500 V To IEC 947 A 1600 3200 6100 For 1 s A 2400 4500 9000 For 2 s A 2000 3750 7580 For 10 s A 1600 3200 6100 For 30 s A 960 1920 3600 Short-circuit protection at le in cat. AC-3 max Auxiliary contact characteristics am fuse A 160 400 630 Rated insulation voltage (Ui) V 690 Conventional thermal current (Ith) A 10 voltage (Ie) AC-15, 230 V A 0.78 AC-15, 400 V A 0.45 AC-15, 500 V A 0.35 DC-13, 24 V A 1.1 DC-13, 110 V A 0.24 DC-13, 220 V A 0.12 Cabling Cable c.s.a. mm 2 2.5 Short-circuit protection Operating time (1) (at 100 % of Uc) gg fuse A 10 Closing C ms ± 5 Opening O ms ± 5 (1) The closing time C is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time O is measured from the moment the coil supply is switched off to the moment the main poles separate. 2

References Contactors 5 Power and control circuits a.c. supply 105944 Vacuum contactors Standard power ratings 50/60 Hz in category AC-3 Rated operational voltage Ie Instantaneous auxiliary contacts Basic reference. Complete with code indicating control circuit voltage (2) Weight 230 V 400 V 525 V 690 V 1000 V AC-3 AC-1 kw kw kw kw kw A A kg 168 45 75 110 150 200 160 160 2 1 LC1-V160pp 3.800 LC1-V320 90 160 220 280 400 320 320 1 1 LC1-V320pp 10.500 500308 160 300 400 560 800 610 630 1 1 LC1-V610pp 13.000 Instantaneous auxiliary contact blocks (1) Number of contacts Maximum number of blocks per contactor Auxiliary contacts Reference Weight kg LA1-VN11 2 4 1 1 LA1-VN11 0.030 2 LA1-VN02 0.030 2 LA1-VN20 0.030 500502 Accessories For assembling reversing contactors Description For use Reference Weight on kg Kit comprising : - 1 mechanical interlock. - 1 set of power connections. LC1-V160 LA9-V974 0.500 LC1-V320 LA9-V975 5.000 500310 LA9-V975 LX1-V320pp Coils Rated voltage Voltage code Reference Weight V kg For contactors LC1-V160 110 120 FE7 LX1-V160FE7 0.400 220 240 P7 LX1-V160P7 0.400 380 415 V7 LX1-V160V7 0.400 440 480 R7 LX1-V160R7 0.400 550 600 X7 LX1-V160X7 0.400 For contactors LC1-V320 110 120 FE7 LX1-V320FE7 0.800 220 240 P7 LX1-V320P7 0.800 380 415 V7 LX1-V320V7 0.800 440 480 R7 LX1-V320R7 0.800 550 600 X7 LX1-V320X7 0.800 For contactors LC1-V610 110 120 FE7 LX1-V610FE7 0.800 220 240 P7 LX1-V610P7 0.800 380 415 V7 LX1-V610V7 0.800 440 480 R7 LX1-V610R7 0.800 550 600 X7 LX1-V610X7 0.800 (1) LC1-V160: auxiliary contact blocks mounted at the top of the contactor, with no change to the overall dimensions. LC1-V320 or LC1-V610: 2 auxiliary contact blocks mounted on the RH and LH side of the contactor, with no change to the overall dimensions.. ((2) Standard control circuit voltages. Volts 50/60 Hz 110 120 220 240 380 415 440 480 550 600 Code FE7 P7 V7 R7 X7 3

Dimensions, mounting, schemes Contactors 5 Dimensions, mounting LC1-V160 48 24 Ø7 500311 168 152 9 Ø7 151 36,5 123 36,5 24 48 LC1-V320 156 133 50 35 70 2xØ10,5 500312 185 222 203 191 3,5 2xØ8,5x19 2xØ8 2xØ8,5 130 159 37 63,5 63,5 201 9,5 48 76 38 170 15 LC1-V610 178 127 68 68 2xØ8,5x19 328 356 222 203 2xØ8,5 9,5 172 15 95 Schemes LC1-V160 32,5 68 68 201 LC1-V320, V610 Auxiliary contact blocks LA1-VN11 1N/O & 1N/C LA1-VN02 2N/C LA1-VN20 2N/O LA1-VN11X 1N/O 14 13/NO 22 21/NC 52 51/NC 62 61/NC 34 33/NO 44 43/NO 04 03/NO coil/ bobine NC 500313 A2 2/T1 4/T2 6/T3 04 14 22 A2 2/T1 4/T2 6/T3 14 22 A1 1/L1 3/L2 5/L3 03/NO 13/NO 21/NC A1 1/L1 3/L2 5/L3 13/NO 21/NC 4

produced by Product and Corporate Communications South Africa Reference: cat001/02 South Africa (Pty) Ltd Reg No 71/02841/07 Corner Bekker & Montrose Roads Midrand Private Bag X139 Halfway House, 1685 Tel +27 11 254 6400 Fax +27 11 315 8830 www.schneider-electric.co.za Branches: Cape Town +27 21 464 4240 Durban +27 31 250 8000 Port Elizabeth +27 41 401 3200 Kenya +254 2 824 156 Reunion +262 281 428 Zambia +260 222 2252 Zimbabwe +263 4 707 179