POWER AND COMMUNICATION REQUIREMENTS FOR THE ALOHA SYSTEM. Version 1.0



Similar documents
Video Camera Installation Guide

Network Design. Yiannos Mylonas

Spectralink IP-DECT Server 400 Base Units

UPS Network Interface. Quick InstallationGuide

Connecting to the Internet

Networks. The two main network types are: Peer networks

PXL-250: Network Wiring

No Phone Line II-48 System

GEU Port Gigabit Switch

Chapter 4 Connecting to the Internet through an ISP

IP DSLAM IDL Quick Installation Guide

No Phone Line System. Quick Start Guide NPL II. 1.0 Installation

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

AC and DC Drive System Installation Information

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Canopy Surge. User Manual

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

Ethernet Patch Cord Wiring

User Guide TL-SG1016D 16-Port Gigabit Switch TL-SG1024D 24-Port Gigabit Switch

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide.

Installation Guide Solar Connect-11

Grounding & Bonding Why it is done And How to Install Properly

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Wireless LAN Outdoor Bridge Solution

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Chapter 9. Bonding and Grounding

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Operation and Installation Manual

DEPARTMENTAL REGULATION

USB Port Extender Kit

TELEPHONE CABLING TECHNOLOGY INFINITY CABLING

800 Communications Circuits

Structured Cabling, Earthing & Equipotential Bonding

TP-LINK TECHNOLOGIES CO.,LTD. Website ADD FI.3,Bldg.R1-B.High-Tech Industrial Park,Shenzhen

Lightning Protection Guide. PTP 400 and 600 SERIES

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

emta (VoIP over Cable Modem)

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Troubleshooting Problems Affecting Radio Frequency Communication

Power, Cable, and Antenna Connection Procedures

HP UPS R1500 Generation 3

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Sending A/V Signals Over Twisted Pair Cables: An Introduction. What is A/V over twisted pair?... 2

2100 POS System User Guide

Implementing Fast Ethernet

INSTALLATION & SERVICE MANUAL. Display Panel

PC Tab INSTALLATION MANUAL SECURE-IT, INC. EAST LONGMEADOW, MA / (fax)

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Electrical Grounding. Appendix C

5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105

Installation Guide Content for P250xV-240 microinverters

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

16-Port and 24-Port 10/100 Switches

Gigabit eco-friendly Ethernet Switch AT-GS900/8. Installation Guide Rev. A

Model Number Electrical Compatibility Module Connector Type. M LL-S22 60 cell PV module MC-4 Type 2 Locking

Future Stars. Grade X Manual Chapter 1 Networking and Telecommunication. telecommunication. Telephones, telegrams, radios and televisions help

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Marine HF SSB Installation and Grounding. Anatomy of the Best Tour 2006

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Moxa EtherDevice Switch

AC Module Installation Guide Content

AVerMedia AVerKey imicro User s Manual

Specifying a Variable Frequency Drive s

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

Technical Support. Support Information

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850

POWER DISTRIBUTION. Power and Undercarpet Products POWER AND UNDERCARPET PRODUCTS. Chapter Summary

16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide

8-Port 10/100M N-Way Mini Switch

Current Probes. User Manual

Lightning Arresters P KVA P KVA. Description & Installation

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

Chapter 1 Connecting the Router to the Internet

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

InnoMedia ESBC B. Quick Install Guide. 1

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION SECURITY SYSTEMS

NETWORKING TECHNOLOGIES

SECTION 22 LIGHTNING PROTECTION SYSTEM

Grounding and Shield Termination. Application Note 51204

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

RC8021 Indoor Camera Installation Guide

Raceway and Boxes for Electrical Systems Page 1 of 7

User Guide TL-SG1016/ TL-SG /24-port Gigabit Ethernet Switch

with Component Rating A Simple Perspective

Transcription:

POWER AND COMMUNICATION REQUIREMENTS FOR THE ALOHA SYSTEM Version 1.0

Copyright Copyright 2003, Aloha Technologies, LTD., Documentation Services. This publication is confidential, proprietary information which is not to be reproduced or disclosed to others without written permission from Aloha Technologies, LTD., Documentation Services. No part of this document may be reproduced, transmitted, stored in a retrieval system, or translated into any language in any form by any means without written permission of Aloha Technologies, LTD. Aloha Technologies, LTD. is not responsible for any technical inaccuracies or typographical errors contained in this publication. Changes are periodically made to the information herein; these changes will be incorporated in new editions of this publication. Any reference to gender in this document is not meant to be discriminatory. The software described in this document is provided under a license agreement. The software may be used or copied only in accordance with the terms of that agreement. Aloha Technologies, LTD., 2003. All Rights Reserved. ALOHA is a U.S. Registered Trademark of Aloha Technologies, LTD. Microsoft, and Windows are registered trademarks of Microsoft, Inc. IBM is a registered trademark of International Business Machines Corporation. Other products mentioned are trademarks or registered trademarks of their respective companies.

Table of Contents Introduction Overview...I-iii AC Power Requirements...I-iii Communication Cable Requirements... I-iv Network Device Location... I-iv Phone Line Requirements... I-iv How This Book is Organized... I-v AC Power Requirements... 1-1 Preferred AC Power System... 1-3 Conductors and Circuits... 1-3 Data Communication Cables... 1-4 AC Power Receptacles... 1-4 Uninterrupted Power Supply (UPS)... 1-5 AC Power System Grounding... 1-5 Aloha Power Panel Grounding... 1-5 Aloha Branch Circuit Grounding... 1-5 Alternate AC Power System... 1-7 Conductors and Circuits... 1-7 Uninterrupted Power Supply (UPS)... 1-7 AC Power Receptacles... 1-8 Relaxed/Power Conditioned AC Power System... 1-10 Non-dedicated Power Panel... 1-10 Dedicated Circuits... 1-10 Conductors and Circuits... 1-10 Power Conditioners... 1-11 Uninterrupted Power Conditioner (UPC)... 1-11 AC Power Receptacles... 1-11 v1.0

Communication Cable Requirements...2-1 Mechanical and Environmental Considerations... 2-3 Lightning... 2-3 Electrical Interference... 2-3 Radio Frequency Interference... 2-3 Shielded Cable vs. Metal Conduit... 2-5 PVC Conduit... 2-6 Network Device Location...3-1 Device Location Planning... 3-3 Manager s Workstation/Ethernet Hub... 3-4 User Workstation... 3-5 Stand-alone (Remote) Printers... 3-6 Cables and Connectors... 3-7 Cable for Printers... 3-7 Ethernet Plate/Jack and Connectors... 3-7 Phone Line Requirements...4-1 Dedicated Phone Line... 4-3 Phone Line Interference... 4-4 Index ii Table of Contents Power and Communication Requirements

Introduction Overview The AC power, communication cable, and phone line requirements for the ALOHA system hardware are discussed, in detail, in this manual. AC Power Requirements There are three choices for the AC power requirements: Preferred AC Power System The installation of a power distribution panel intended for the sole use of the Aloha POS system hardware is the preferred method of providing power. This method ensures that electrical noise produced by other equipment does not create interference for the Aloha POS system hardware. Alternate AC Power System The power for the Aloha POS system hardware is provided directly from the main or source power panel. This option is recommended for existing construction where the current facilities do not justify the installation of a dedicated power panel. Relaxed/Power Conditioned AC Power System When providing either of the above options is cost prohibitive and/or would require major structural changes, this method may be used.

Communication Cable Requirements When designing the site, it is important to address mechanical and environmental issues that could affect the system hardware. The cabling must be protected from environment variables such as lightning, electrical interference, and radio frequency interference. The type of cable to use must also be determined. Grounded ferrous metal conduit is expensive to install but provides the best protection. Network Device Location A map diagramming the location of the network hardware is vital when determining the number and types of cable runs between the workstations (POS terminals), the Ethernet hub, and the stand-alone printer devices. Phone Line Requirements It is optimal to have two dedicated phone lines to the server; one line is needed for the Aloha Electronic Draft Capture application, and the other is used for remote communications. iv Introduction Power and Communication Requirements

How This Book is Organized The following chapters outline the power requirements for the Aloha system hardware: Introduction This chapter is a basic introduction to the power system requirements for the Aloha system hardware. Chapter 1: AC Power Requirements This chapter discusses the different options available when determining the AC power system to use for the Aloha system hardware installation. Chapter 2: Communication Cable Requirements This chapter discusses the communication cable requirements for the Aloha system hardware. Discussions include mechanical and environmental considerations, shielded cable vs. metal conduit, and PVC conduit. Chapter 3: Network Device Location This chapter discusses the network device location. Discussions include manager s workstation/ethernet hubs, user workstations, and stand-alone printers. A list of recommended cables and connectors is also included. Chapter 4: Phone Line Requirements This chapter discusses the phone line requirements for the Aloha system. Index Power and Communication Requirements Introduction v

vi Introduction Power and Communication Requirements

AC Power Requirements This chapter discusses the AC power requirements for the Aloha system hardware. There are three options: the Preferred AC Power System, the Alternate Power System, and the Relaxed/Power Conditioned AC Power System. Preferred AC Power System... 1-3 Conductors and Circuits... 1-3 Data Communication Cables... 1-4 AC Power Receptacles... 1-4 Uninterrupted Power Supply (UPS)... 1-5 AC Power System Grounding... 1-5 Aloha Power Panel Grounding... 1-5 Aloha Branch Circuit Grounding... 1-5 Alternate AC Power System... 1-7 Conductors and Circuits... 1-7 Uninterrupted Power Supply (UPS)... 1-7 AC Power Receptacles... 1-8 Relaxed/Power Conditioned AC Power System... 1-10 Non-dedicated Power Panel... 1-10 Dedicated Circuits... 1-10 Conductors and Circuits... 1-10 Power Conditioners... 1-11 Uninterrupted Power Conditioner (UPC)... 1-11 AC Power Receptacles... 1-11 Chapter 1

1 2 AC Power Requirements Power and Communication Requirements

Preferred AC Power System To ensure that electrical noise produced by other equipment does not create interference for the Aloha system hardware, all power conductors and equipment grounding conductors must be isolated from other power circuits in the facility. To accomplish this, the installation of a power distribution panel intended for the sole use of the Aloha system hardware is the preferred method of providing power. No other equipment should run off this circuit. AC Power Requirements A dedicated power panel is not used to supply other electrical loads in the facility, and is supplied by a feeder run directly from the main or source panel for the facility. Personal computers, and/or stand-alone devices are powered from a single circuit. All branch circuits include a separate neutral (ground conductor) and equipment grounding conductor, unless otherwise indicated. The following information does not supplant national, state, or local electrical codes. Conductors and Circuits A ferrous metal conduit with separate neutral and ground conductors is required for each branch circuit. Aluminum conduit is not acceptable. If the length exceeds 100 feet, increase all conductors (including ground) one wire size for each additional 100 feet of length. The neutral conductor from the main or source panel to the dedicated Aloha panel must be two sizes larger than the phase conductors. This is to accommodate the third harmonic current caused by switching power supplies in the Aloha user workstations, and to minimize the possibility of common mode noise occurring on the power distribution circuits. All power distribution circuits must be installed in a dedicated ferrous metal conduit containing only the Aloha supply and ground conductors. Power and Communication Requirements AC Power Requirements 1 3

Data Communication Cables Separate ferrous metal conduits are required for data communication cables. AC Power Receptacles NEC Article 250-74, Exception 4, permits installation of the isolated ground receptacles and isolated equipment grounding conductors specified in this section. To maintain isolation of the equipment-grounding conductor from the conduit system, an isolated ground receptacle must be used. This type of receptacle (usually identified by an orange face) provides an insulating barrier between the equipment grounding terminal and the receptacle mounting strap. All branch circuits from the Preferred AC power panel must be terminated with isolated ground receptacles. All AC power receptacles must be the isolating ground type. Standard receptacles bond the equipment-grounding terminal (green screw) to the receptacle mounting strap and metallic conduit when the receptacle is mounted to the box. This defeats the purpose of the isolated grounding system. No equipment bonding jumper is installed from the receptacle grounding terminal to the outlet box. If a duplex receptacle is installed and only one socket is used, the unused socket should be disconnected to prevent the temptation of using the outlet for equipment such as floor buffers, vacuum cleaners, etc., that may produce extraneous ground currents. Approved ground receptacle types are: Receptacle Type NEMA P/N 125V, 15A, Simplex IG5-15RI 125V, 15A, Duplex IG5-15R2 1 4 AC Power Requirements Power and Communication Requirements

Uninterrupted Power Supply (UPS) Each Aloha system processor (provided with the Aloha equipment package) requires an approved UPS; however, the best way to protect the Aloha system is to have an approved UPS on the dedicated circuit. AC Power System Grounding AC Power Requirements Proper grounding of the AC power system is critical to achieve a high degree of equipment performance and reliability. A separate equipment grounding system must be installed to minimize the introduction of electrical noise. The following outlines the specific grounding requirements: Aloha Power Panel Grounding An insulated equipment grounding conductor (sized the same as the supply conductors) must be installed in the same conduit as the supply conductors from the main or source panel to the dedicated Aloha equipment panel. This equipment-grounding conductor is terminated on the ground bus in the main panel. Install a ground bus at the Aloha equipment panel that is electrically isolated from the panel frame, and terminate the feeder equipment grounding conductor on this bus bar. The metallic feeder conduit is used as the equipment grounding system for grounding the AC power panel frame, metallic conduit system, and metallic junction boxes. Aloha Branch Circuit Grounding Each branch circuit from the dedicated power panel to the Aloha System Device receptacles must include a full sized (same as supply conductors) insulated equipment grounding conductor installed in the same conduit as the supply conductors. The conduit must be dedicated to the Aloha equipment. Power and Communication Requirements AC Power Requirements 1 5

Terminate the isolated grounding conductor on the isolated ground bus bar in the panel, and on the equipment grounding terminal of a NEMA IG5-15 isolated grounding type receptacle. Figure 1-1 Figure 1-1 Display of a Preferred AC Power System Panel 1 6 AC Power Requirements Power and Communication Requirements

Alternate AC Power System For existing construction where the existing facilities do not justify the installation of a dedicated power panel, an alternate method may be employed. This method provides power for the Aloha system hardware devices directly from the main or source power panel. It is imperative that system components are supplied from the main or source panel. No system component is to be supplied from any other power panel. AC Power Requirements The following does not supplant national, state or local electrical codes. Conductors and Circuits All Aloha system hardware and system processor(s) must be supplied with circuits that run directly from the main panel. No other equipment should run off circuits used by the Aloha system hardware. Branch circuits must be installed in a dedicated ferrous metal conduit and include a full sized (same as the supply conductors) insulated equipment grounding conductor installed in the same conduit. Aluminum conduit is not an acceptable alternative to ferrous metal. Terminate the isolated grounding conductors at the ground bus in the main or source panel. Do not terminate grounding conductors on any metallic conduit, water pipe, or ground rod. Uninterrupted Power Supply (UPS) Each Aloha system processor (provided with the Aloha equipment package) requires an approved UPS; however, the best way to protect the Aloha system is to have an approved UPS on the dedicated circuit. Power and Communication Requirements AC Power Requirements 1 7

AC Power Receptacles NEC Article 250-74, Exception 4, permits installation of the isolated ground receptacles and isolated equipment grounding conductors specified in this section. To maintain isolation of the equipment-grounding conductor from the conduit system, an isolated ground receptacle must be used. This type of receptacle (usually identified by an orange face) provides an insulating barrier between the equipment grounding terminal and the receptacle mounting strap. All branch circuits from the Alternate AC power panel must be terminated with isolated ground receptacles. All AC power receptacles must be the isolating ground type. Standard receptacles bond the equipment-grounding terminal (green screw) to the receptacle mounting strap and metallic conduit when the receptacle is mounted to the box. This defeats the purpose of the isolated grounding system. No equipment bonding jumper is installed from the receptacle grounding terminal to the outlet box. If a duplex receptacle is installed and only one socket is used, the unused socket should be disconnected to prevent the temptation of using the outlet for equipment such as floor buffers, vacuum cleaners, etc., that may produce extraneous ground currents. Approved ground receptacle types are: Receptacle Type NEMA P/N 125V, 15A, Simplex IG5-15RI 125V, 15A, Duplex IG5-15R2 1 8 AC Power Requirements Power and Communication Requirements

AC Power Requirements Figure 1-2 Figure 2.1 Display of an Alternate AC Power System Panel Power and Communication Requirements AC Power Requirements 1 9

Relaxed/Power Conditioned AC Power System When providing the Preferred or Alternate AC Power System is cost prohibitive and/or would require major structural changes, the Relaxed AC Power System may be used. The Preferred or Alternate AC Power System is recommended for the Aloha system hardware. Non-dedicated Power Panel Any power panel supplying heavy equipment within the facility should not be selected as the non-dedicated power panel supplying the Aloha equipment. Dedicated Circuits Aloha AC power circuits must be dedicated for Aloha system equipment. These circuits must provide power to the Aloha system equipment only. Conductors and Circuits All Aloha AC power branch circuits must originate from the same non-dedicated power panel equipped with an isolated ground bus that is electrically isolated from the panel frame. This panel must be provided with an insulated equipment grounding conductor (sized the same as the supply conductors) that is installed in the same conduit as the supply conductors from the main or source power panel. Terminate the equipment-grounding conductor on the ground bus in the main or source panel, and on the isolated ground bus in the non-dedicated power panel. 1 10 AC Power Requirements Power and Communication Requirements

The conduit used for the Aloha AC power circuits must be ferrous metallic. Flexible, rigid, or greenfield metallic conduit is acceptable. Aluminum conduit is not acceptable. Each dedicated Aloha AC power circuit must include an M size (same as supply conductors) insulated equipment grounding conductor installed within the same dedicated conduit system as the supply conductors. AC Power Requirements Terminate the ground conductor in the non-dedicated power panel, and on the grounding terminal of each isolated ground AC power receptacle. Power Conditioners Aloha approved power conditioners are required at all Aloha remote printer locations (this is provided with the Aloha equipment package). Uninterrupted Power Conditioner (UPC) Each Aloha personal computer requires an approved UPC. AC Power Receptacles NEC Article 250-74, Exception 4, permits installation of the isolated ground receptacles and isolated equipment grounding conductors specified in this section. To maintain isolation of the equipment-grounding conductor from the conduit system, an isolated ground receptacle must be used. This type of receptacle (usually identified by an orange face) provides an insulating barrier between the equipment grounding terminal and the receptacle mounting strap. Terminate all branch circuits from the Relaxed/Power Conditioned AC Power System panel to the isolated ground receptacles. All AC power receptacles must be the isolating ground type. Standard receptacles bond the equipment-grounding terminal (green screw) to the receptacle Power and Communication Requirements AC Power Requirements 1 11

mounting strap and metallic conduit when the receptacle is mounted to the box. This defeats the purpose of the isolated grounding system. No equipment bonding jumper is installed from the receptacle grounding terminal to the outlet box. If a duplex receptacle is installed and only one socket is used, the unused socket should be disconnected to prevent the temptation of using the outlet for equipment such as floor buffers, vacuum cleaners, etc., that may produce extraneous ground currents. Approved ground receptacle types are: Receptacle Type NEMA P/N 125V, 15A, Simplex IG5-15RI 125V, 15A, Duplex IG5-15R2 1 12 AC Power Requirements Power and Communication Requirements

Communication Cable Requirements This chapter provides information on selecting and installing the cables that connect Aloha hardware devices to the PC workstations and Ethernet LAN Hub. Mechanical and Environmental Considerations... 2-3 Lightning... 2-3 Electrical Interference... 2-3 Radio Frequency Interference... 2-3 Shielded Cable vs. Metal Conduit... 2-5 PVC Conduit... 2-6 Chapter 2

2 2 Communication Cable Requirements Power and Communication Requirements

Mechanical and Environmental Considerations When designing the site, mechanical and environmental considerations need to be addressed. This helps to eliminate damage that can occur from disruptions caused by the environment or mechanical devices. The possibility of mechanical damage to cables includes outdoor runs of cable since sunlight, rain, and mechanical flexing due to wind causes the cable to deteriorate. To protect cables, it is strongly recommended that a grounded ferrous metal conduit is used. Lightning Communication Cables Lightning does not need to directly strike the cabling to cause damage or disruption to the system. Nearby lightning strikes produce strong electromagnetic fields that can induce voltages on the data transmission cables, possibly causing disruptions or damage. A grounded ferrous metal conduit should be employed for installations in geographical areas subject to frequent thunderstorm activity. If shielded cables are used, placing the cable runs as close to ground level as possible can reduce the effects of lightning. Electrical Interference Electrical motors of various sizes are found in a typical restaurant site. A grounded ferrous metal conduit should be employed when cabling must be run at a distance less than two feet from motors that are 1/4 horsepower or smaller, or less than six feet from motors larger than 1/4 horsepower. Shielded cable can be considered if it is possible to maintain the above minimum distances. Radio Frequency Interference The probability of radio frequency interference (RFI) varies in accordance with many factors, including transmitter power, location of the transmitter, materials used in the construction of the building, and physical placement of Power and Communication Requirements Communication Cable Requirements 2 3

the power and data transmission cables. Other possible causes of RFI include nearby amateur radios, CB radios, radio-dispatched trucks and taxis, cordless phones, and cordless headsets. As a general rule, a grounded ferrous metal conduit should be employed when the installation is within one mile of a broadcast transmitter of any type. As with lightning, the effects of RFI are minimized by placing the cable runs as close to ground level as possible. 2 4 Communication Cable Requirements Power and Communication Requirements

Shielded Cable vs. Metal Conduit Two main goals when installing data transmission cables are to prevent mechanical damage and to prohibit disruptions due to outside electrical interference. In general, a properly grounded ferrous metallic conduit provides the best electrical and mechanical protection, but is more expensive to install, especially at an existing site. Selection of a grounded ferrous metal conduit vs. shielded cable requires consideration of both expense and the degree to which occasional disruptions can be tolerated. All Aloha data transmission cables must be installed within a separate grounded ferrous metal conduit when non-shielded cable is used. Aluminum conduit is not an acceptable alternative as it provides little or no protection from Electromagnetic Interference (EMI). The use of conduit must be continuous throughout the system from junction box to junction box to ensure a proper ground return path. Communication Cables No other power or communication cables should be run in the same conduit. Power and Communication Requirements Communication Cable Requirements 2 5

PVC Conduit PVC Conduit can be employed when cables must be buried below the floor level. When using PVC conduit, an Aloha approved shielded data transmission cable must be used. When installing PVC conduit in concrete flooring, the following guidelines apply: The PVC conduit should be located at least six inches below the surface of the floor. The PVC conduit should be located at least six inches from other nearby conduits. If the PVC conduit run is in the middle of a metal conduit run, a ground wire must be run through the PVC conduit to connect the metal conduit together at both ends. This ensures a complete AC ground path for the metal conduit. No other power or communication cables should be run in the same conduit. 2 6 Communication Cable Requirements Power and Communication Requirements

Network Device Location This chapter discusses the location of the network hardware for the Aloha system. Discussions include the manager s workstation, the user workstation, and stand-alone printers. The last section lists the recommended cables and connectors for the Aloha hardware system. Device Location Planning... 3-3 Manager s Workstation/Ethernet Hub... 3-4 User Workstation... 3-5 Stand-alone (Remote) Printers... 3-6 Cables and Connectors... 3-7 Cable for Printers... 3-7 Ethernet Plate/Jack and Connectors... 3-7 Chapter 3

3 2 Network Device Location Power and Communication Requirements

Device Location Planning The layout of the installation site is the determining factor in network hardware location. A blueprint of the restaurant showing the locations of the hardware devices on the floor plan or riser diagram is required to determine the physical location of all devices in the Aloha system. From this, the number and types of cable runs between the user workstations (POS terminals), manager s workstation, Ethernet hub located in the manager s office (close to the manager s workstation), and stand-alone printer devices (broiler, fryer, expediter, and beverage printers) can be determined. An Aloha approved CAT5-10BaseT four-pair 24 gauge shielded or nonshielded cable is installed for all connections between the Ethernet hub, manager s workstation, and user workstations. The same cable is also used for all connections between the stand-alone printers and a user s workstation. Each Aloha POS terminal can drive one local printer and one stand-alone remote printer. If non-shielded cable is used, it is required to be installed in a grounded ferrous metal conduit. When more stand-alone remote printers are required than the number of user workstations, additional RS232 Communication Boards can be added to a user workstation (provided with the Aloha hardware package). Network Device Location Power and Communication Requirements Network Device Location 3 3

Manager s Workstation/Ethernet Hub The hardware in the manager s office consists of a PC workstation (server), PC monitor, PC keyboard, modem, laser reports printer, an Ethernet hub, and an uninterrupted power supply. Ethernet CAT5-10BaseT four-pair 24 gauge shielded or non-shielded cable from each user workstation is terminated in a patch panel next to the server computer. The manager s workstation is attached to the Ethernet hub and CAT5 patch cables are used from the hub to the patch panel to connect the terminals. Grounded ferrous metal conduit is required if non-shielded cable is used. 3 4 Network Device Location Power and Communication Requirements

User Workstation A user workstation consist of a personal computer, touch screen monitor, magnetic credit card swipe reader, uninterrupted power supply and an RS232 cable connected local printer. Ethernet CAT5-10BaseT four-pair 24 gauge shielded or non-shielded cable runs from each user workstation and is terminated at the patch panel located in the manager s office. Five feet of excess cable should be left outside the data cable junction box to allow for a sufficient length of cable for proper termination (POS terminals and manager s office). Grounded ferrous metal conduit is required if non-shielded cable is used. The communication cable is terminated at the user workstation with a female RJ45 CAT5 plate/jack. Network Device Location Power and Communication Requirements Network Device Location 3 5

Stand-alone (Remote) Printers Stand-alone printers consist of broiler, fryer, expediter, beverage printers, etc. The number of printers varies per restaurant. Ethernet CAT5-10BaseT four-pair 24 gauge shielded or non-shielded cable is used to connect stand-alone devices. The same pinouts used for the terminals are also used for the printer connections, attached in a point-to-point configuration to a user workstation. Five feet of excess cable should be left outside the data cable junction box to allow for a sufficient length of cable for proper termination. 3 6 Network Device Location Power and Communication Requirements

Cables and Connectors The following is a list of recommended cables and connectors for the Aloha system hardware: Cable for Printers Use Ethernet CAT5-10BaseT four-pair 24 gauge shielded or non-shielded cable for printers. Recommended manufacturers are Bertek or an equivalent manufacturer. Ethernet Plate/Jack and Connectors An RJ45 CAT5 plate/jack is required for the user workstation cable termination. Mount one jack (in the wall) per terminals. Recommended manufacturers are Panduit s or an equivalent manufacturer. The part number is MUJC588 or MFPD1EI. An RJ45 CAT5 plate/jack is required for the Ethernet hub cable termination. Recommended manufacturers are Panduit or an equivalent manufacturer. The part number is MFPD4EL or MFPD1E. Network Device Location Power and Communication Requirements Network Device Location 3 7

3 8 Network Device Location Power and Communication Requirements

Phone Line Requirements This chapter discusses the phone line requirements for the Aloha system. Dedicated Phone Line... 4-3 Phone Line Interference... 4-4 Chapter 4

4 2 Phone Line Requirements Power and Communication Requirements

Dedicated Phone Line It is optimal to have two protected dedicated phone lines to the server to prevent damage that can be caused by mechanical and environmental factors. A dedicated phone line is not shared with any other device. One line is needed for the Aloha Electronic Draft Capture application. The second line is needed for remote communications by Aloha Technologies, LTD. for the use of Symantec s pcanywhere. Phone Line Requirements Power and Communication Requirements Phone Line Requirements 4 3

Phone Line Interference Phone (PBX) systems can cause interference, cross talk, and roll-over onto these lines; therefore, the phone line must be a straight run from the d-mark to the phone jack. For additional security from external interference, shielded CAT5 cable should be used to run these lines. Using a UPS with phone line protection helps to prevent damage to the computer caused by lightning and other voltage producers. 4 4 Phone Line Requirements Power and Communication Requirements

Index A Alternate AC Power System 1-7 AC power receptacles 1-8 conductors and circuits 1-7 uninterrupted power supply 1-5, 1-7 approved ground receptacle types 1-4, 1-8, 1-12 B branch circuit grounding 1-5 C communication boards 3-3 D data transmission cables 2-5 dedicated phone line 4-3 E electrical interference 2-3 equipment performance and reliability 1-5 Ethernet cable 3-4, 3-5, 3-6 Ethernet hub 3-3, 3-7 Ethernet plate/jack and connectors 3-7 H hub 3-7 J junction box 3-6

L layout 3-3 lightning 2-3 M manager s workstation 3-4 mechanical and environmental considerations 2-3 N non-shielded cable 3-3, 3-4, 3-5, 3-6, 3-7 P patch cables 3-4 patch panel 3-4, 3-5 phone line interference 4-4 pinouts 3-6 power panel grounding 1-5 Preferred Power System AC power receptacles 1-4 AC power system grounding branch circuit grounding 1-5 power panel grounding 1-5 conductors and circuits 1-3 data communication cables 1-4 dedicated power panel 1-3 electrical noise 1-3 printer cable 3-7 PVC conduit 2-6 R radio frequency interference 2-3 Relaxed/Power Conditioned AC Power System 1-10 AC power receptacles 1-11 conductors and circuits 1-10 dedicated circuits 1-10 non-dedicated power panel 1-10 S power conditioners 1-11 uninterrupted power conditioners 1-11 shielded cable 2-3, 2-5, 3-3, 3-4, 3-5, 3-6, 3-7 shielded data transmission cable 2-6 stand-alone (remote) printers 3-6 T third harmonic current 1-3 U uninterrupted power supply 1-5, 1-7 user workstation 3-5 I - 2 Index Power and Communication Requirements