Unica for KNX system 226



Similar documents
B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

How To Use A Power Supply On A Powerline 2.2 (Ai)

Unica for KNX system P105927

Movement/monitoring 1307/1.0 (6325xx)

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Busch-Watchdog Presence EIB Type:

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

Light scene push button 8gang comfort flush-mounted xx

Inwall 4 Input / 4 Output Module

Product and Application Description

Glass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

Inwall Room Temperature Unit

Tebis application software

PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP )

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Basics of Dimming. ISC Learning Centre

Drayton Digistat +2RF/+3RF

ABB i-bus EIB Logic Module LM/S 1.1

Using presence detectors with alarm systems

Push button 3gang standard flush-mounted xx

RRV934. Multi-controller. Synco living

Product data base 2.63 (ETS2 1.2 ETS3.0c / vd2-file) Instabus KNX/EIB System

ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB.

Operating instructions. RCD flat 4-fold, 6-fold

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

KNX Lighting Control System

The application is now available in 8 languages. (German, English, French, Spanish, Italian, Russian, Dutch, Polish)

Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T

NO 1 IN SMART HOUSE AND HIGH TECH BUILDING TECHNOLOGIES

Transmitter Actuator 230V wave UP 560. Operation

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M ES/M , ES/M

PRODUCT MANUAL. InZennio Z38i. KNX Touch Panel ZN1VI-TP38i. Program version: 2.2 Manual edition: a

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Controls for fan coil units and cassettes

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Operating instructions II / 2004

Niko Home Control. Installation Manual

Application Unit, MDRC AB/S 1.1, GH Q R0111

PART 1 PRODUCT (GENERAL)...1.

HERZ-Thermal Actuators

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

The house is a machine for living. Le Corbusier, Toward an Architecture, 1923

B.IQ push-button with room temperature regulation and display OPERATING AND ASSEMBLY MANUAL

Configuration example: Scene function in the actuator channel in the ETS. 1 Introduction

basicdim DGC Compact control module

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S Intelligent Installation Systems ABB

24 Wide Screen LED Monitor with HDMI

Instruction manual for models:

KNX Gateway RGK E-01

The role of home and building control in the smart city. Joost Demarest KNX System & Administration Director

ABB i-bus KNX i-bus Tool Product Information

Product and functional description

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Power Line Carrier technology

B/S/H/ Error codes and service programmes PH

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Operating instructions IV / 2007

Technical Manual MDT Rain sensor

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

ABB Powernet KNX. Product manual. Intelligent Installation Systems. ABB i-bus KNX ABB Powernet KNX

ABB i-bus KNX Application manual Heating/Ventilation/Air Conditioning

Simplicity is the ultimate sophistication. Leonardo da Vinci

Passion for KNX innovation

Please refer to the chapters below for detailed information about all aspects of the products usage.

Controlers. Controler

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Transmitter Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

ABB i-bus EIB / KNX Room Controller

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

More efficiency in office buildings with HVAC, lighting and security

IDDERO HOME SERVER. Quick start guide

ABB i-bus KNX SA/S Switch Actuators Product Manual

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

15-INCH TFT-LCD MONITOR

Smart buildings in smart grids KNX City. Rafael Marculescu May 2013

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Passion for Innovation

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

T-100-R Installation Guide

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

Power Socket (2 Gang)

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries.

Smile. The All-In-One Heating Controller

Thermostat with display

Belimo Gateway MP to Modbus RTU - UK24MOD

Tebis KNX Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 131

VFS24/32HDIP. Public Display IP Monitor User Manual

Energy Saving Tips. They can have a dramatic impact on your bill. The cheapest energy is the energy you don t use.

Transcription:

Unica for KNX system 6

P117504 Greater flexibility and comfort, better energy efficiency with KNX More and more electronic appliances are needed for modern comfortable homes that contain everything from computers to home cinemas. Does this mean simply increase electricity consumption despite rising energy costs? better, faster, cheaper and cleaner solution is to use energy more efficiently. This is not only better for the environment but for your wallet too. P10593 7

Intelligent and good looking home P117500 8

Connect Unica to your KNX system! P117503 Reading in your favourite armchair in the evening, watching TV on the sofa or dining with family or friends is all the more comfortable if you don t have to get up to switch each light, lamp or thermostat on or off individually. By setting up individual scenes for instance using a Unica multi-function push-button you can combine a wide range of different functions. Once a scene has been created, it can be started at the push of a button to create a suitable light mood when watching TV or reading for instance or when leaving the house in the morning. If, when doing so, you want the blinds to be raised, the lights switched off and heating turned down, you can activate the «Not at home» scene and all functions will be executed automatically. Push-button Can be used to control lights or roller blinds. The system can be used to control lights and roller blinds according to the sunlight when coupled with a sensor. IR push-button Can be used to control lights or roller blinds. Can be controlled by KNX IR remote control. utomatic lighting control Can activate roller blinds or lights The system can be used to control lights and roller blinds according to movement detection in corridors, staircases. Individual heating control Presence-dependent room heating. Heat is supplied automatically at the exact time required and individually via controllable room temperature control units. No need to turn the radiators up and down manually. Don t worry: if you forget to do it, the KNX system will remember to do it for you. P10593 P119163 P119165 P119161 P119164 P11916 Interested by the intelligent system? See KNX catalog 9

Unica KNX Quick selection guide Unica KNX range Product type Description Notes Range Colour Reference P11731 P117316 P11730 Push-button, buttons and blue status LEDs, with screwless bus connecting terminals Push-button, 4 buttons and 4 blue status LEDs, with screwless bus connecting terminals Push-button, buttons, blue status LED and Infra Red (IR) receiver, with screwless bus connecting terminals The status LED is located under the symbol window which can be taken off. The status LED is located under the symbol window which can be taken off. The status LED is located under the symbol window which can be taken off. The functions of each of the button can be triggered using an IR remote control. The push-button is pre-programmed for operation with a Schneider Electric IR remote control Distance. Many other IR remote controls (e.g. existing TV or CD player remote controls) can be taught into the push-buttons. Class, Top aluminium MGU3.530.30 graphite MGU3.530.1 Plus, Colors, Basic white MGU3.530.18 ivory MGU3.530.5 Class, Top aluminium MGU3.531.30 graphite MGU3.531.1 Plus, Colors, Basic white MGU3.531.18 ivory MGU3.531.5 Class, Top aluminium MGU3.53.30 graphite MGU3.53.1 Plus, Colors, Basic white MGU3.53.18 ivory MGU3.53.5 P115471 Infra Red (IR) remote control for IR push-button receiver Class, Top, Plus, Colors, Basic black MTN570 P11734 P11738 Movement detector Class, Top aluminium MGU3.533.30 graphite MGU3.533.1 Plus, Colors, Basic white MGU3.533.18 ivory MGU3.533.5 Room temperature control unit Class, Top aluminium MGU3.534.30 graphite MGU3.534.1 Plus, Colors, Basic white MGU3.534.18 ivory MGU3.534.5 Detailed presentation of the range Unica Class, Unica Top: see page 57. Unica Plus, Unica Colors, Unica Basic: see page 111. 30 ISC01064_1-009_EN

Unica KNX Technical information Depending on the push-button, you have either two or four operating surfaces available to which you assign different functions via the ETS. For example, you can: Switch and toggle Dimming Control blinds Save and retrieve scenes Call up linear regulator functions Save edge functions If required, you can disable the buttons and define the type of disabling. The push-button with an IR receiver will allow you to operate each push-button by IR remote control as well. Technical data Power supply: DC 4 V KNX connection: bus connecting terminal Display elements: Status LEDs 1 programming LED Operating elements: Control keys 1 programming button mbient operating temperature: -5 C to +45 C IR receiver: ngle of reception: approx. 60 Reception range: Dependent on the IR remote control used IR channels: 9 Type of protection: IP 0 Initialisation: The device is ready for operation after 5 to 10 seconds. Push-buttons buttons and blue status LEDs 4 buttons and 4 blue status LEDs buttons, blue status LED and Infra Red (IR) receiver Connections, displays and operating elements 1 1 B Status LEDs B IR receiver (no status LED) 1-4: Button assignment in the ETS 1 Bus connection B Programming LED C Programming button B c 3 4 Software functions Switching, toggling Dimming (single/dual-surface) Blind (single/dual-surface) Pulse edges trigger 1-, -, 4- or 8-bit telegrams (distinction between short and long operation) Pulse edges with -byte telegrams (distinction between short and long operation) 8-bit linear regulator Scene retrieval Scene saving Disable functions. ISC01064_1-009_EN 31

Unica KNX Technical information Movement detector rea of application Movement detector for indoors. The movement detector detects moving heat sources, (e.g. people), within a radius of 180 and up to a distance of approx. 9 m at an mounting height of.15 m. The range refers to average conditions for the specified mounting height and is therefore a guide value. The range and sensitivity can vary greatly when the temperature fluctuates. When a movement is detected, a defined data telegram is transmitted. The rotary switch for detection brightness is used to regulate from which ambient brightness level at which movements should be detected. Here, values between 10 and 1000 lux are possible (in the ETS value from 10 to 000 lux are possible). The range and the overshoot time can be set at two further rotary switches. The movement detector also has two movement sensors. You can set their sensitivity and range sector-specifically in the ETS. The movement detector has an integrated bus coupler and its power is supplied via KNX. Technical data ngle of detection: 180 Number of movement sensors:, sector-orientated, adjustable (ETS) Recommended mounting height: 1 m to,5 m Range: at.15 m mounting height, approx. 9 m on all sides, adjustable in 10 steps (rotary switch or ETS) Detection brightness: infinite setting from approx. 10 lux to approx.1000 lux (rotary switch) or from 10 lux to 000 lux (ETS) Overshoot time: adjustable in 6 steps from approx. 1 s to approx. 8 min (rotary switch) or adjustable from 1 s to 55 hours (ETS) Standards EC guidelines: Low-voltage guideline 006/95/EEC and EMC guideline 004/108/EC. Software functions Five movement blocks: up to four functions can be triggered per block. Telegrams: 1 bit, 1 byte, bytes. Normal operation and surveillance operation, master, slave, safety pause, disable function. Sensitivity, brightness and staircase timer can be set using the ETS or the potentiometer. Two movement sensors: the sensitivity and range can be set separately for each sensor. Self-adjusting staircase timer. Connections, displays and operating elements B C Cover B Setting the detection brightness C Setting the overshoot time D Setting the range Use 0s 1s 40s 80s 3min 8min D B C Bus connection B Programming LED C Programming button Observe the area of detection: ny mounting height which deviates from this will affect the range. m,15 0 4 6 8 10m 8 6 4 0 4 6 8 Install the movement detector laterally with respect to the direction of movement so that the beam paths are intersected as vertically as possible. Only mount the movement detector in positions which allow the required area to be monitored optimally. In order to ensure continuous monitoring, e.g. of a long hall, the areas of detection have to intersect. Movement detectors can detect all objects that radiate heat. You should select an installation site that will not result in undesired heat sources being detected, such as: switched-on lights in the area of detection open fires (such as in fireplaces) windows where the influence of alternating sunlight and clouds could cause rapid changes in temperature. larger heat sources (e.g. cars), that are detected through windows. sunlit rooms with reflecting objects (e.g. the floor), which can be the cause of rapid changes in temperature. windowpanes heated up by sunlight dogs, cats, etc. Install movement detectors in a wind-resistant switch box: With switch boxes and pipe cabling systems, a draught at the back of the equipment could trigger the movement detector. void direct sunlight. This can destroy the sensor in extreme cases. 3 ISC01064_1-009_EN

KNX room temperature control unit rea of application The Room temperature control unit with display (referred to as Controller from here on) can be used for heating and cooling with infinitely variable KNX valve drives or for controlling switch actuators and heating actuators. Technical data Power supply: via KNX Power consumption: approx. 9 m Connection: bus connecting terminal Display elements: 1x display Operating elements: 4 push-buttons Measuring range: 0 to 40 C Measuring accuracy: ± 1 K, depending on installation site; offset can be parameterised Operating temperature: -5 C to +45 C Controller type: -step Continuous PI controller Switching PI controller (PWM) Controller mode: heating with 1 controller output Cooling with 1 controller output Heating and cooling with separate controller outputs -step heating with controller outputs -step cooling with controller outputs Type of protection: IP 0 EC guidelines: Low-voltage guideline 006/95/EEC EMC directive 004/108/EEC Use KNX Room temperature control unit with display and 4 buttons. buttons allow to shift set values and change operation modes, the other buttons are used for navigation in the menu. The room temperature control unit can be used for heating and cooling with infinitely adjustable KNX valve drives or to trigger switch actuators and heating actuators. With the white backlit display for showing e.g. the time, date, temperature and operating mode. Menu for setting default operating modes, setpoint value, working/non-working day (external trigger), display mode, time, switching times and brightness of the display. 110...160 mm Sources of interference Connections, displays and operating elements Software functions Functions of the room temperature control unit: Controller type: -step control, continuous PI controller, switching PI controller (PWM) Output: continuous in the range 0 to 100% or switching ON/ OFF Controller mode: Heating with one controller output Cooling with one controller output Heating and cooling with separate controller outputs Heating and cooling with one controller output -step heating with control outputs -step cooling with control outputs -step heating and cooling with 4 control outputs Operating modes: Comfort, comfort extension, standby, night reduction, frost/heat protection Move all setpoints, save all setpoint temperatures and operating modes when reset, external temperature monitoring, additional output of the control value as 1 byte value on the PWM. Monitoring function for the actual temperature, valve protection function. Functions of the push-buttons: Selection of 1-4 operating modes each push-button. Move setpoint. 1 3 4 1 + 4: Menu navigation push-buttons + 3: Push-buttons Display B C D B Bus connection C Programming LED D Programming button ISC01064_1-009_EN 33