RRV934. Multi-controller. Synco living
|
|
|
- Mildred Reed
- 9 years ago
- Views:
Transcription
1 s Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard (868 MHz, bidirectional) Mains-powered AC 230 V 3 universal relay outputs 1 additional output for 3-position actuator, or as a 4th universal relay output 4 universal inputs 2 universal outputs DC 0 10 V Use For integration into the Siemens Synco living system Designed for use in heating plants for precontrol of up to 2 room groups 2 primary controllers each with 1 DC 0 10 V actuator 1 primary controller with a DC 0 10 V actuator and 1 primary controller with a 3-position actuator With flow and return temperature limitation, optional control of room group pumps and DHW heating. Suited for control of 3-stage ventilation plant including HR bypass, with influence from humidity, indoor air quality or CO 2 level, fault supervision Forwarding of heat demand signal to primary energy plant CE1N2709en Building Technologies
2 Equipment combinations The RRV934 multi-controller is designed for use with the Siemens Synco living system. For more detailed information about equipment combinations, refer to the Data Sheet covering the central apartment unit CE1N2707en. Application examples Precontrol of 2 independent room groups Radiator heating and low-temperature floor heating with flow temperature control, maximum limitation and maintained return temperature RRV934 U1 Q1 T X1 RRV91x SSA955 T1 2709H01 T X3 U2 Q2 Y1 T2 T X2 T X4 Primary controller Heating circuits room Precontrol: X1 X2 Flow temperature sensor X3 X4 Return temperature sensor Q1 / Q2 Room group pump U1 / U2 Mixing valve (DC 0 10 V) Heating circuits room: Y1 Heating circuit valve (2- or 3-position) T1 / T2 Room unit and / or room temperature sensor (QAW910 and / or QAA910) Suited for use with the system are all electromotoric and electrohydraulic actuators featuring 3-position or DC 0 10 V control supplied by SBT HVAC Products. For detailed information, refer to product range overview of Acvatix valves and actuators C en. Also refer to the Data Sheet covering the heating circuit controllers RRV912 CE1N2705en and RRV918 CE1N2706en. 2 / 12
3 Integration of ventilation plant RRV934 X1 Q1 Q2 Q3 I II III X2 FOL X3 ZUL AUL ABL 2709H02 M Q4/Q5 Q1 / Q2 / Q3 Q4 / Q5 X1 / X2 X3 FOL AUL ZUL ABL 3-stage step selector of ventilation plant HR bypass, 3-position actuator Humidity, indoor air quality or CO 2 sensor, DC 0 10 V Fault / maintenance contact (e.g. for monitoring a filter) Exhaust air Outside air Supply air Extract air Ordering When ordering, please give quantity, product name and type reference. Scope of delivery The RRV934 is supplied complete with Mounting Instructions. Product documentation The Operating and Commissioning Instructions for the RRV934 are contained in the product documentation supplied with the central apartment unit. Functions Main function The RRV934 multi-controller is used for connection and control of ventilation plant and / or for control of hydraulic room groups. All inputs and outputs are suited for universal use. The central apartment unit delivers the relevant data via RF. 3 / 12
4 Universal relay outputs Universal inputs Universal outputs The universal relay outputs are capable of controlling different pieces of equipment, such as 3-stage ventilation units. Release is controlled via the central apartment unit and ensured via RF. 1 The universal inputs accept the signals from different sensors used for room group precontrol or for control of ventilation plant. 1 The RRV934 converts percentage-scaled signals from the central apartment unit (e.g. heat demand) to analog DC 0 10 V signals. The outputs can also be used for control of the room group valves, for instance (DC 0 10 V). 1 Special functions for use with the room group primary controller Outside temperaturecompensated minimum flow temperature Flow temperature control / limitation Limitation of the return temperature Cooling mode The minimum flow temperature setpoint is raised depending on the composite outside temperature, thus ensuring a minimum flow temperature (e.g. in connection with uncontrolled rooms). The flow temperature can be controlled via the RRV934. It is regulated with the help of the heat demand signal. Minimum or maximum limitation of the flow temperature setpoint can be provided, based on an adjustable value. If the temperature request is invalid, flow temperature regulation becomes inactive and the controlling elements are closed (no output of heat). The return temperature can be maintained at a high or low level, based on an adjustable value. Extremely hot water returning to the heat source can thus be prevented, for instance. Return temperature limitation is given priority over flow temperature limitation. The primary controller s valve is fully opened and the room group pump activated. It runs continuously during the period of time cooling mode is active and is not influenced by locking signals. The room valves (RRV91x and SSA955) ensure the hydraulic distribution of chilled water in accordance with the room s configuration. Specific ventilation functions Stage selection Humidity sensor Ventilation contact On the central apartment unit, a ventilation stage can be defined for each operating mode. If there is no humidity or CO 2 / VOC control, the operating modes can be run according to a time program. The humidity sensor monitors the acquired relative humidity and ensures the adjusted limit value is not exceeded. If the relative humidity exceeds the limit value, the ventilation system is switched to a selectable ventilation stage. With each central apartment unit, a maximum of 1 humidity sensor can be used. Using the ventilation input contact, ventilation plant can be set to a selectable ventilation stage. The wave AP 260 door / window contact, a universal input of an RRV91x heating circuit controller, a universal input of an RRV934 multi-controller, or an S-Mode object can act on the ventilation contact (OR operation). 1 For detailed information on assignment options for the inputs and outputs, refer to the Synco living Mounting and Commissioning Instructions (CE1C2707en). 4 / 12
5 Indoor air quality control Night cooling Smoke alarm Holiday function Apartment timer Forced ventilation Open fireplace function Exhaust hood Service message Window airing Absence The CO 2 or VOC sensor monitors the indoor air quality. The indoor air quality controller calculates a positioning signal, based on the current setpoint (in accordance with the ventilation level) and the current indoor air quality. From this, the linear step selector determines the ventilation stage currently required. A total of 2 setpoints can be defined (setpoint 1: Protection / Economy; setpoint 2: Precomfort / Comfort). Indoor air quality must be acquired in the room itself and not in the air duct, since air does not circulate around a duct sensor when the ventilation system is shut down so that adequate control could not be ensured. With each central apartment unit, a maximum of 1 CO 2 or VOC sensor can be used. If, in summer operation, the room temperature rises above the outside temperature and night cooling is active, the ventilation plant is operated at a selectable ventilation stage during night hours also. In that case, the HR bypass is released also. If the smoke detector triggers an alarm, the central apartment unit can be set to a selectable ventilation stage (or OFF) via the central apartment unit. To prevent stale room air during holiday periods, the ventilation plant can be switched on at selectable intervals. The ventilation stage can be selected also. During holiday periods, no consideration is given in terms of control to the levels of humidity, indoor air quality and CO 2. Priority is given to smoke alarms however. The apartment timer also acts on the ventilation plant. The ventilation plant can be manually operated at the highest stage for a predefined period of time. If the ventilation plant uses an open fireplace function so that the plant is externally overridden, the contact can be connected via a universal input. In that case, a special symbol indicating open fireplace mode appears on the display of the central apartment unit. To prevent excessive underpressure when operating the exhaust hood, the hood can be released via a universal output. Release is effected as soon as the supply of sufficient air is ensured via a window. A service message Service ventilation can be delivered based on the number of operating hours of the ventilation unit (total of all 3 ventilation stages). For that, a service interval can be parameterized on the central apartment unit. The window airing function is triggered by the central apartment unit. When a selected window contact responds, the ventilation plant switches to a selectable ventilation stage. When the window is closed again, the ventilation plant resumes normal operation. A ventilation stage can be defined for the absence function. During holiday periods, no consideration is given in terms of control to the levels of humidity, indoor air quality and CO 2. Priority is given to smoke alarms however. 5 / 12
6 Device and system functions Binding State query RF binding test Disconnecting channel from the system Supply state RF failure Mains failure The binding of the first selected channel or channel group is used by the RRV934 to sign on at the central apartment unit, thus ensuring integration into the RF system. Then, the other channels or channel groups can be assigned to other functions. The binding process is triggered via the multifunction button and indicated by the multifunction LED. The multifunction button can be used to query the state of the configured control channels. The state is indicated by the multifunction LED. The multifunction button can be used to trigger a binding test per channel. The test is made to check the radio link to the central apartment unit. The RF binding test is indicated by the multifunction LED. Using the multifunction button, a channel that has already been connected, or a channel group, can be disconnected from the system. In that case, the respective channel or channel group is reset to the supply state. Then, the channel or channel group can again be reconnected to the system. The state is indicated by the multifunction LED. Using the multifunction button, the RRV934 can be reset to the supply state. Then, the RRV934 can be reconnected to the system. If the RF link between RRV934 and central apartment unit breaks down, control of the room groups and the ventilation plant is no longer ensured. When radio transmission is reestablished, the RRV934 returns to control mode. If power supply to the RRV934 is cut, control of the heating groups and ventilation plant is no longer ensured. The positions of the individual actuators can only be changed manually on the actuators themselves. When power supply is restored, the RRV934 returns to control mode. 6 / 12
7 Operating and indicating elements Multiunction LED Channel selection button Channel LED Mains LED U1 U2 X1 X2 X3 X4 Q1 Q2 Q3 Q4 Q5 2709Z01 Function of operating elements Operating elements Multifunction button Channel selection button Function State query of channel configuration RF binding test Binding Disconnection of channel and channel groups from the system Restoration of supply state Channel and channel group selection Function of indicating elements Indicating element Multifunction LED Channel LEDs: U1 U2 X1 X4 Q1 Q3 Q4 / Q5 Mains LED Function Indication of channel and channel group configuration RF binding test Binding process Disconnection of channel and channel groups from the system Indication of channel configuration / status indication: Universal output Universal input Universal relay output Universal relay output (Q4) or 3-position output (Q4 / Q5) Power supply For more detailed information about the functions and operation of the RRV934, refer to the product documentation covering the central apartment unit. 7 / 12
8 Notes on engineering and operation Mounting location Due to its compact design, the RRV934 can be fitted directly in the electrical distribution panel*, heat distribution panel*, on the ceiling in the cellar, or in the cable riser The permissible environmental conditions must be observed The RRV934 must not be exposed to dripping water For notes relating to engineering and mounting RF devices of the Siemens Synco living system, refer to Data Sheet CE1N2708en When mounting the RRV934, ensure that there is sufficient space by the connection terminals to introduce the cable ( 30 mm) At the top of the unit, a minimum clearance of 50 mm must be observed to ensure that the operating elements can be accessed and 30 mm that the terminal cover can be easily opened * Plastic covers are used in place of metal covers to support radio communication 2705Z02de 50 mm Mounting Note Commissioning Maintenance Disposal The RRV934 is designed for: Mounting on top hat rails conforming to EN TH35-7,5 Fitting with the help of 2 fixing screws Prior to applying power, connect all inputs and outputs. Prior to commissioning, check to ensure that the RRV934 is correctly mounted, that all wiring is correctly made, and that power is switched on. The RRV934 is maintenance-free. In terms of disposal regulations, the RRV934 is classified as electronic scrap conforming to the European Directive 2002/96/EG (WEEE) and must not be disposed of as domestic waste. The relevant national regulations must be observed and the unit must be disposed of through the appropriate channels. Local and currently valid legislation must be observed. Warranty Application-related technical data are only warranted in connection with the Siemens Synco living system. For equipment combinations, refer to the Data Sheet covering the central apartment unit CE1N2707en. When using the RRV934 together with third-party devices, correct functioning must be ensured by the user. In that case, Siemens will assume no responsibility for service or warranty. 8 / 12
9 Technical data Power supply Operating voltage AC 230 V (± 10%) Frequency 50 Hz Power consumption (excluding extern. loads) max. 7 VA Fusing of supply line 10 A RF Frequency Range Protocol 868 MHz (bidirectional) Typically 30 m inside buildings KNX RF-compatible Universal input Permissible cable length to sensor or external contact Universal relay output Universal output Electrical connections Type LG-Ni1000 resistor, on / off, DC 0 10 V Quantity 4 Measuring range C Copper cable 0.6 mm dia. max. 20 m Copper cable 1 mm 2 max. 80 m Copper cable 1.5 mm 2 max. 120 m Type NO contact AC V, AC (2) A Quantity 5 Type DC 0 10 V, max. DC 1 ma Quantity 2 Screw terminals for max. 2.5 mm 2 Type of controller Primary controller PI Standards Protection Environmental compatibility conformity to EMC directive - Immunity, Emissions Low-voltage directive - Electrical safety RTTE Radio & Telecom. Equipment - Radio communication 2004/108/EC - EN , EN /95/EC - EN , EN /5/EC - EN , EN EN Safety class II to EN Housing IP30 to EN Degree of pollution 2 to EN Environmental Declaration CM1E2709en contains data on environmental-compatible product design and assessment (RoHS compliance, compositions, packaging, environmental benefits and disposal) ISO (environment) ISO 9001 (quality) SN (environment-compatible products) RL 2002/95/EG (RoHS) Dimensions Weight Housing material Housing colors Unit complete with accessories Upper / lower housing section refer to Dimensions kg Plastics PC+ABS RAL 7035 light-gray RAL 5014 dove-blue 9 / 12
10 Environmental conditions Operation Transport Storage EN EN EN Climatic conditions Class 3K5 Class 2K3 Class 1K3 Temperature C C C Humidity 5 95% r.h. <95% r.h. 5 95% r.h. (noncondensing) Mechanical conditions Class 3M2 Class 2M2 Class 1M2 Elevation above sea level min. 700 hpa, corresponding to max m above sea level Connection terminals Protective extra-low voltage U1, U2 Universal output DC 0 10 V M Ground for universal output X1 X4 Universal input (digital input, sensor input or DC 0 10 V) M Ground for universal input Mains voltage or protective extra-low voltage Q13, Q14 Potential-free universal relay output (NO) for AC V (relay 1) Q23, Q24 Potential-free universal relay output (NO) for AC V (relay 2) Q33, Q34 Potential-free universal relay output (NO) for AC V (relay 3) Q43, Q44 Potential-free universal relay output (NO) for AC V (relay 4), or if used as a 3-position output: Q43 Input for Q44 and Q54 Q44 Actuator / valve open for AC V Q54 Actuator / valve closed for AC V N1 Connection of neutral conductor (AC V) for internal mixing valve interference suppression Mains voltage N Operating voltage, neutral conductor AC 230 V L Operating voltage, live conductor AC 230 V Connection diagram Example: Universal inputs and outputs L 2) L L X1 M X2 M X3 M X4 M AC 230 V N1 N N U1 M U2 M Q13 Q14 Q23 Q24 Q33 Q34 Q43 Q44 N Q54 3) 3) 1) N 2709A02 N1 Multi-controller RRV934 1) Universal output DC 0 10 V 2) Universal input, can be used for temperature measurement / digital input / DC 0 10 V 3) Universal potential-free relay output, can be used for mains or low-voltage 10 / 12
11 Example: Controlled ventilation of apartment: Step selector, HR bypass AC 230 V N1 Multi-controller RRV934 Y3 Actuator HR bypass, 3-position AC 230 V 1) Universal output DC 0 10 V 2) Universal input, can be used for temperature measurement / digital input / DC 0 10 V 3) Relay 1 (Q1) of 1-stage step selector 4) Relay 1 (Q1) and relay 2 (Q2) of 2- or 3-stage step selector 5) Relay 1 (Q1), relay 2 (Q2) and relay 3 (Q3) of 3-stage step selector * The behavior of relays with each stage can be selected on the central apartment unit Example of controlled apartment ventilation: Step selector, HR bypass, AC 24 V N1 Multi-controller RRV934 Y3 Actuator HR bypass, 3-position, AC 24 V 1) Universal output DC 0 10 V 2) Universal input, can be used for temperature measurement / digital input / DC 0 10 V 3) Relay 1 (Q1) of 1-stage step selector 4) Relay 1 (Q1) and relay 2 (Q2) of 2- or 3-stage step selector 5) Relay 1 (Q1), Relay 2 (Q2) and relay 3 (Q3) of 3-stage step selector * The behavior of relays with each stage can be selected on the central apartment unit 11 / 12
12 Example of precontrol: Primary controller 1 with actuator, 3-position, AC 230 V, primary controller 2 with actuator, DC 0 10 V N1 Multi controller RRV934 B1 Flow temperature sensor for primary controller 1 (LG-Ni1000) B2 Return temperature sensor for primary controller 1 (LG-Ni1000) B3 Flow temperature sensor for primary controller 2 (LG-Ni1000) B4 Return temperature sensor for primary controller 2 (LG-Ni1000) M1 Room group pump 1 for primary controller 1 M2 Room group pump 2 for primary controller 2 Y1 Valve actuator primary controller 1, 3-position, AC 230 V Y2 Valve actuator primary controller 2, DC V 1) Universal output DC V 2) Universal potential-free relay output, can be used for mains or low-voltage The function of the various inputs and outputs is defined only when connecting the individual channels to the central apartment unit. This means that the room group pumps can be connected to any of the relay outputs Q1 Q3. The temperature sensors too can be connected to any of the inputs X1 X4. In place of the 3-position valve actuator for primary controller 1, it would also be possible to connect a DC 0 10 V valve actuator to output U1. Dimensions Dimensions in mm 1,5 27,4 35,3 27,4 8,5 20,2 ø 5 7,2 230,5 12 / Siemens Switzerland Ltd Subject to change
QFP910. Water detector. Building Technologies. CE1N2732en. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
HVAC central apartment unit with consumption data acquisition
s 2 741 Synco living HVAC central apartment unit with consumption data acquisition Series A QAX903 Heating and cooling control management for an apartment including precontrol for 2 room groups Ventilation
QFP910. Water detector. Building Technologies. CE1N2732en 2016-03-01. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
HVAC central apartment unit with consumption data acquisition
s 2 741 Synco living HVAC central apartment unit with consumption data acquisition Series A QAX903 Heating and cooling control management for an apartment including precontrol for 2 room groups Ventilation
RVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
Heating Controller. Building Technologies HVAC Products
2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or
SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
Flush-mounted room thermostats
s 3 076 RDF300, RDF300.02, RDF340 RDF400.01 RDF600 RDF600 Flush-mounted room thermostats for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units for use with compressors in DX type equipment RDF300
How To Control A Korean Korean Power Plant
2 510 District Heating Controller for 1 heating circuit and d.h.w. heating RVD120 RVD140 ultifunctional heating controller for use in district heating substations and district heating plants with odbus
Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems
s 3 72 Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems RDU34 KNX bus communications (S-mode and LTE mode) Backlit display PI / P control Outputs for DC 0 0
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
OZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
OZS164... Web server. For LPB/BSB plants
s 5 711 Web server For LPB/BSB plants OZS164... Remotely operate and monitor a LPB or BSB device Web browser operation via PC/laptop or Smartphone SMS operation via mobile phone (OZS164.23) 2 digital inputs
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
HCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
FDCI222, FDCIO222, FDCIO224 Input module Input/output modules
FDCI222, FDCIO222, FDCIO224 Input module Input/output modules addressable (FDnet/C-NET) Sinteso Cerberus PRO Input module FDCI222 with 4 monitored contact inputs for the acknowledgement of technical states
OZW772... V2.0. Web server. Synco TM, Synco TM living
s 5 701 Web server Synco TM, Synco TM living OZW772... V2.0 The OZW772 web server allows for remote operation and monitoring of plants via the web and send faults and system reports to e-mail recipients.
2- and 3-port valves with flanged connections, PN 10
4 402 VVF32.. VXF32.. ACVATIX 2 and 3port valves with flanged connections, PN 10 From the largestroke valve line VVF32.. VXF32.. Performance valves for medium temperatures from 10 150 C Valve body of grey
For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.
s For UK only RX39.1 and the applications package SP-03 are sold in the United Kingdom only. 3 876 3876P01 RX Room controller Communicating controllers for fan-coil applications SP-03 RX39.1 The RX39.1
VAV compact controller KNX / PL-Link
s 3 547 OpenAir VAV compact controller KNX / PL-Link Series E GDB181.1E/KN GLB181.1E/KN Networked compact controller featuring KNX (S-mode / LTE-mode) and PL- Link capability for plants with variable air
Butterfly Valves PN 6/10/16 for flanged connection
4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40
Actuator for modulating control AME 435
Data sheet Actuator for modulating control AME 435 Description The actuator automatically adapts its stroke to the valve end positions which reduces commissioning time (self stroking). The advanced design
Product and Application Description
Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Air damper actuators
4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically
DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.
1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings. 02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring
INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS
VMC A4 INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS PRODUCT DATA SHEET FEATURES RF to 0-10 VDC out, analogue or PWM Maximal 3 digital inputs to RF RF communication with other equipment Wireless
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke
Adjustable room thermostat for heating only or cooling only systems
3 003 Room hermostat RAA30 Adjustable room thermostat for heating only or cooling only systems Room thermostat with manual O/OFF switch wo-position control witching voltage AC 24 250 V Use he RAA30 room
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
HVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
J TB/TW Temperature limiter, temperature monitor
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: [email protected] Internet: www.jumo.net
VAV compact controller KNX / PL-Link
s 3 547 OpenAir VAV compact controller KNX / PL-Link Series E GDB181.1E/KN GLB181.1E/KN Networked compact controller featuring KNX (S-mode / LTE-mode) and PL- Link capability for plants with variable air
Flush-mount room temperature sensor AQR2531ANW.
1 408 Flush-mount room temperature sensor AQR2531... Passive sensor to acquire room temperature. Field of use 0 +50 C Use In heating, ventilation and air conditioning plants, primarily in the comfort range
Building Technologies
Building Technologies RXB room automation system System overview Contents Comfort and well-being in every room...5 Range overview...6 Coordinated room controllers...7 The room units: the key to individual
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
GREISINGER electronic GmbH
T38.0.0X.6C-03 CO2 - Transmitter Operating Manual GT10 - CO2-1R GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 Tel.: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, email: [email protected]
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
ABB i-bus KNX Fan Coil Controller FC/S 1.1
Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
Thermostatic Actuators
2 111 EN 215-1 RTN51 with remote sensor RTN81 with remote adjuster Thermostatic Actuators for radiator valves VDN, VEN, VUN, VPD and VPE RTN51 RTN81 Self-acting, without auxiliary power High-quality fluid-filled
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
Answers for infrastructure. HVAC control with Synco simple and energy-efficient
Answers for infrastructure. HVAC control with Synco simple and energy-efficient Synco for enhanced comfort and energy efficiency Buildings place different requirements on HVAC control systems depending
Transmitter Actuator 230V wave UP 560. Operation
Transmitter ctuator 230V wave UP 560 5WG3 560-201 Product- and pplication Description Diagram The transmitter actuator 230V wave UP 560 (Diagram ) is a flush-mounted device with radio communication for
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
TCR easy Plus Alarm. Operating Instructions
TCR easy Plus Alarm Operating Instructions Table of Contents General.....................................4 Installation...................................5 Putting into Operation............................5
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
OZW772... V4.0. Web server. For Synco TM, Synco TM living
s 5 701 Web server For Synco TM, Synco TM living OZW772... V4.0 Web server OZW772 allows for remote plant control and monitoring via the web and Smartphone-App. Four versions of the web server are available:
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
HCE80/HCC80/HCE80R/HCC80R
HCE80/HCC80/HCE80R/HCC80R UNDERFLOOR HEATING-ZONEING CONTROLLERS PRODUCT DATA FEATURES Easy and fast installation because the new wiring design Pluggable terminals for fast wiring connection because clamp
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
Smile. The All-In-One Heating Controller
Smile EVERYTHING UNDER CONTROL The All-In-One Heating Controller Versatile, energy-efficient heating control. The All-In-One Heating Controller Smile controllers are ideal to gain maximum efficiency from
Input module, input/output module
Sinteso / Cerberus PRO Input module, input/output module FDCI221, FDCIO221 Input module and input/output module for the automatically addressed detector line Input module FDCI221: Monitorable contact input
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring
Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions
Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy
Room Temperature Sensors
1 721 1721P010 1721P020 QAA25 QAA27 oom Temperature Sensors with and without setpoint adjuster...27 Use In heating, ventilating and air conditioning plants, especially where a high level of comfort is
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
KNX Panasonic Air Conditioners
IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line
IntesisBox KNX Mitsubishi Heavy Industries AC
IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)
47000 SERIES - ELECTRONIC TRANSFORMERS
7000 SERIES - ELECTRONIC TRANSFORMERS MYRRA encapsulated electronic transformers are Switched Mode Power Supplies based on Flyback topology. They constitute an interesting alternative to the traditional
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
Model: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description
Safety Manual BT50(T) Safety relay / Expansion relay
Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
Nest Learning Thermostat Installation Guide. Installation step-by-step
Nest Learning Thermostat Installation Guide Installation step-by-step Contents Compatibility. 3 In the box. 4 Before you start. 5 Choose an installation method. 6 Replacing an existing wired thermostat.
OZW672...V5.2. Web-Server. For LPB/BSB plants
s 5 712 Web-Server For LPB/BSB plants OZW672...V5.2 Web server OZW672 allows for remote plant control and monitoring via the web and Smartphone-App. Web server is available in three versions: To connect
(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
T5000 T000 LCD Digital Fan Coil Thermostat
T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,
ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch
echnical data sheet Rotary actuator LR-S Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage C... 4 V Control: Open/close or -point uxiliary switch echnical data Electrical data
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
IntesisBox KNX LG Air Conditioning
IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit
Smoke exhaust systems
1 Fire zone, e.g. hall 2 Smoke exhaust zone, separated by smoke curtains Natural and mechanical smoke extraction General information 3 Natural smoke and heat exhaust vent 4 Air inlet opening or wake max.
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
Variable speed drives
5 192 Variable speed drives SED2 Variable speed drives for speed control of three-phase a.c. motors actuating fans or pumps. Range: 0.37 kw to 90 kw for IP20, IP21 version, 1.1 kw to 90 kw for IP54 version.
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
Unica for KNX system 226
Unica for KNX system 6 P117504 Greater flexibility and comfort, better energy efficiency with KNX More and more electronic appliances are needed for modern comfortable homes that contain everything from
SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected