Transmitter Actuator 230V wave UP 560. Operation
|
|
|
- Alvin Kristian Townsend
- 10 years ago
- Views:
Transcription
1 Transmitter ctuator 230V wave UP 560 5WG Product- and pplication Description Diagram The transmitter actuator 230V wave UP 560 (Diagram ) is a flush-mounted device with radio communication for switching electrical loads. It is possible to connect a 1-fold or 2-fold instabus push button (to be ordered separately) or a motion detector (in development) via a 10-pin plug-in connector. Via the push button rocker(s) of a plug-in instabus push button, it is possible to operate the integrated actuator locally and to operate as well other radio controlled actuators via remote control. Scenes can also be stored in the actuators and retrieved. The transmitter actuator 230V wave is connected to the 230V network and supplied with current via an integrated power supply unit. The actuator can be controlled both locally and via radio. The connected load is switched via a relay contact, whereby it can be set whether the load should be permanently switched on or off (normal operation) or whether the actuator should operate in time switch mode, with an adjustable operating time of 1, 5 or 15 minutes. When the operator interface is removed, the commissioning of the transmitter actuator 230V wave can be carried out without any special tools via the six DIL switches located at the front of the device (Easy mode Push utton: EP). There are two different operation modes for the transmitter actuator 230V wave: Normal function With an instabus push button: local operation of the integrated switch actuator, operation of other actuators that are linked via radio, storing and retrieving of scenes With motion detector: control of the integrated switch actuator as well as reporting detected movements to other devices that are linked via radio Special function Establishing connections to its own actuator and to other radio-controlled components Deleting connections to its own actuator and to other radio-controlled components Operation The 1-fold or 2-fold instabus push button placed on the transmitter actuator 230V wave can be operated at the TOP or OTTOM. The exact operational functionality depends on the devices connected via radio control: switching, dimming, shutter control or scene function. Switching (ctions shorter than 0.4s): TOP In connection with a switch actuator: ON; in connection with a dimmer: switching on with saved memory value OTTOM OFF Dimming (ctions longer than 0.4s): TOP Dimming RIGHTER up to max. light intensity OTTOM Dimming DRKER down to min. light intensity Shutter STEP command (ctions shorter than 0.4s): TOP STOP/OPEN slats (by 1 step) OTTOM STOP/CLOSE slats (by 1 step) Shutter UP/DOWN command (ctions longer than 0.4s): TOP UP command OTTOM DOWN command Scene function: Preselected states for the lighting (ON or OFF or any brightness value) and the shutters (UP or DOWN) can be saved in a scene and reset via a push button action. Up to four scenes can be saved and retrieved with the transmitter actuator 230V wave. If a 1-fold instabus push button is used, scenes 1 and 2 are operated via the rocker. If a 2-fold instabus push button is used, scenes 1 and 2 are operated via the left rocker and scenes 3 and 4 are operated via the right rocker. efore saving a scene, each switch, dimmer and shutter control insert sys or radio-controlled actuator that is linked via radio must be set to the state to be stored: Switch actuator: ON or OFF Dimmer: Desired light intensity value Shutter: TOP or OTTOM (limit position) a) Saving scenes (ctions longer than 3s): When saving a scene, each connected actuator saves the current state under the activated scene number. TOP Saves scene 1 (or scene 3 when operating OTTOM Saves scene 2 (or scene 4 when operating b) Retrieving scenes (ctions shorter than 0.4s): When retrieving a scene, each connected actuator is set to the state that has been stored under this scene number. Siemens G wave UP 560, 6 pages Technical Manual utomation and Drives Group Electrical Installation Technology Siemens G 2005 Update: P.O. ox , D Regensburg /1
2 Transmitter ctuator 230V wave UP 560 5WG TOP OTTOM Retrieves scene 1 (or scene 3 when operating Retrieves scene 2 (or scene 4 when operating Technical Specifications Frequency band 868 MHz (transmission is not susceptible to interference; frequency band reserved for system and security applications) Range of radio control approx. 100 m (applying to free field applications) Power supply via the 230V mains connection, rated voltage: C 230V, 50Hz Fusing required via 10 circuit-breaker with characteristic or Outputs Number: 1 (Relay contact) Rated voltage: C 230V, Rated current: 6, cos phi = 1 Rated load: - Incandescent lamps: 1000 W - LV halogen with conv. transformer: 500 V - LV Halogen with electron. transf.: 600 V - Fluorescent lamps with elect. ballast: 150 V Connections 3 screw terminals for mains and load connection; Insulation strip length: approx. 5 mm The following conductors are permitted per screw terminal: - two solid conductors 0.5 to 1.5 mm² - one solid or finely-stranded conductor 0.5 to 2.5 mm² 10-pole socket connector for the connection of a 1-fold or 2-fold instabus push button Mechanical specifications Housing: plastic Dimensions: - Spacer units: 71 x 71mm - Mounting depth: 32 mm Weight: approx. 70 g Fire load: approx kj Mounting: inserted in box mounts according to DIN , 60 mm, min. depth 40 mm. Electrical safety Pollution degree (acc. to IEC ): 2 Protection (acc. to EN 60529): IP 20 Overvoltage category (acc. to IEC ): III Device complies with EN Electromagnetic compatibility complies with EN , EN , EN Environmental specifications Climatic conditions: EN mbient operating temperature: C Storage temperature: C Relative humidity (non-condensing): 5% to 93% - stan- Certification VDE certificate in preparation, complies with dard radio frequency rf easy mode push button EP CE norm complies with the EMC regulations (residential buildings), low voltage regulations and R&TTE regulations: The CE declaration can be inspected at: SIEMENS G Siemensstraße Regensburg Installation instructions Notice: The installation of the device into metal walls has to be avoided since this reduces the range of radio control. Occasionally the transmission range may be influenced by structural conditions (e.g. reinforced concrete) or electric / electronic sources of interference. minimum distance of 1 m must be maintained between the transmitter and the relevant receivers. Though the radio transmission is carried out in the safe 868 MHz range, disruptions to the radio transmission cannot be excluded. The used radio transmission is not suitable for security applications. V DNGER The device may be used for interior installations and in dry rooms only. The device must be mounted and commissioned by an authorised electrician. The device must not be opened. The device may be mounted in switch and socket combination box mounts provided that only VDE-certified devices are used. The prevailing safety and accident regulations must be observed. Technical Manual wave UP 560, 6 pages Siemens G utomation and Drives Group Update: Siemens G 2005 Electrical Installation Technology P.O. ox , D Regensburg /2
3 Transmitter ctuator 230V wave UP 560 5WG D Mounting The transmitter actuator 230V wave is connected to the mains cable (L and N conductor) (Diagram ) and inserted in a boxmount (Ø 60 mm and 40 mm depth) using screw or claw fixing. 1-fold or 2-fold instabus push button or a motion detector with the relevant frame (ordered separately) is placed on the transmitter actuator 230V wave with guide and mounting clamps (Diagram C). C1 Installation box (60 mm Ø, acc. to DIN ) C2 Transmitter actuator 230V wave UP 560 C3 Mounting claws C4 Mounting slots for screw fixing C5 Cable for mains and load connection C6 10-pole socket connector C7 Mounting screws C8 Frame C9 instabus push button C 230 V N L Location and Function of the Display and Operating Elements D2 SIEMENS 5WG instabus rf EP Wandsender ktor 230V wave UP 560 Transmitter ctuator 230V wave UP 560 D1 L N µ Un ~ 230V/50Hz In 6 µ Diagram C1 D3 D2 Made in Germany 0125! Diagram D D1 DIL switches for selecting the function and connecting the transmitter actuator via radio control D2 LED for displaying the operating state while the connections to other radio control components are established D3 10-pole socket connector for connecting an instabus push button or a motion detector C2 C4 C6 C7 C5 C4 C3 Dimension Diagram Dimensions in mm C8 C9 Diagram C Siemens G wave UP 560, 6 pages Technical Manual utomation and Drives Group Electrical Installation Technology Siemens G 2005 Update: P.O. ox , D Regensburg /3
4 Transmitter ctuator 230V wave UP 560 5WG Commissioning Note: The transmitter actuator 230V wave must be connected to the 230V cable for the commissioning. The commissioning of the transmitter actuator 230V wave is carried out without the instabus push button via the 6 DIL switches (D1) located at the front and is indicated via the flashing of the LED (D2) located beside the DIL switches. Function of the DIL switches Diagram E shows the DIL switches in the supplied state. In the lower switch position, a DIL switch is switched off (=OFF) while it is switched on in the upper switch position (=ON). efore connecting a rocker, all the DIL switches should be switched off. Switches K1 to K3 are used for the assignment of the channels to the applied rocker or for selecting the actuator. If a 1-fold instabus push button is used or when using a motion detector, DIL switch K1 must be used for commissioning the device. If a 2-fold instabus push button is implemented, DIL switch K1 is required for commissioning the left rocker while DIL switch K2 is required for commissioning the right rocker. DIL switch K3 is used for commissioning the actuator. K1 1-fold rocker or left rocker, motion detector K2 Right rocker K3 ctuator Diagram F3 indicates that the relevant DIL switch must first be switched to the corresponding position according to the required function. F1 F2 F3 Diagram F Diagram G shows which position the function switches F1 to F3 must be switched to in order to preselect a specified function: Diagram G1 Function: Switching Diagram G2 Function: Switching / Dimming Diagram G3 Function: Shutter control Diagram G4 Function: Scene control Diagram G5 Function: Detection of movement fterwards only one of the channel switches K1 or K2 has to be switched to position. G1 G2 G3 Diagram E The DIL switches F1 to F3 can be used for setting the available functions of switching, switching/ dimming, shutter control or scene function when the transmitter actuator is operated with a push button or they can be used for selecting the motion detector function when the actuator is operated with a motion detector. Diagram F shows various switch displays that are used in the subsequent diagrams to explain the commissioning process. Diagram F1 is used to display a triggered action. If the switch is moved from the position to the position, a local assignment or a connection via radio control is triggered. Diagram F2 is used to show a position which the relevant DIL switch must occupy. Diagram G Diagram H shows how the actuator operation mode is set via switches F1 to F3 either to normal operation or to time switch mode with an operating time of 1, 5 or 15 minutes. Switches F1 to F3 must first be set to the required actuator operation mode in accordance with Diagrams H1 to H4 and then switch K3 must be switched on (until the LED flashes) and then off again when the LED has stopped flashing. G4 G5 Technical Manual wave UP 560, 6 pages Siemens G utomation and Drives Group Update: Siemens G 2005 Electrical Installation Technology P.O. ox , D Regensburg /4
5 Transmitter ctuator 230V wave UP 560 5WG Diagram H1 Normal operation (continually ON/OFF) Diagram H2 Time switch mode: 1 minute Diagram H3 Time switch mode: 5 minutes Diagram H4 Time switch mode: 15 minutes When connecting the integrated actuator via radio control, switches F1 to F3 must always be set to the required actuator operation mode. Diagram H Initial commissioning If a push button or a motion detector is placed on a transmitter actuator that is connected to 230V for the first time or after a master reset (see below), the transmitter actuator detects the connected device and automatically links it with the integrated actuator. In the case of a push button, the actuator is set to normal operation and the rocker or both rockers are linked to the actuator. If the right rocker of a 2-fold push button is later linked with another radio-controlled actuator, the internal link to the transmitter s own actuator that was created automatically is deleted and must be taught in again if required. The automatic connection of the left rocker or the rocker of a 1-fold push button to the actuator remains intact however even when it is connected to another radiocontrolled actuator. If another device type is placed onto a taught-in transmitter actuator (e.g. a motion detector instead of the previous push, the sensor part of the transmitter actuator cannot function until the previous device is connected again or the new device has been taught in correctly (e.g. via a master reset before connecting a new device). Connection via radio control: Diagrams J and K indicate the connection of the rocker or the left rocker of a transmitter actuator 230V wave with a single rocker or a twin rocker with another radiocontrolled actuator e.g. a switch insert sys with a plug-in push button wave. H1 H3 H2 H4 J1 J2 Diagram J J1 Transmitter actuator 230V wave UP 560 J2 Push button wave UP 210 J3 Switch insert sys Diagram K 1. Radio-controlled actuator: Switch to the special function. (see the commissioning instructions of the radio controlled actuator) 2. Transmitter: Select the required function via DIL switches F1 to F3 according to diagram G. 3. Transmitter: Trigger a connection telegram via DIL switch K1 (Diagram K). ction: Switch DIL switch K1 to position. The transmitter sends a connection telegram. Display: When K1 has been toggled, the LED of the transmitter actuator flashes slowly for approx. 2 seconds (approx. once per second). fter a successful connection, the LED flashes rapidly for approx. 2 seconds (approx. twice per second) and is then extinguished. If a connection cannot be established, the LED is already extinguished after the first period of 2 seconds when it was flashing slowly. The teaching-in process must then be repeated. 4. Transmitter: Reset all the DIL switches to. Note: If the DIL switches are inadvertently not reset to position after the connection, this is indicated by the LED of the plug-in instabus push button which continuously flashes at a rapid rate. If the transmitter actuator 230V wave should be linked with other radio-controlled actuators, the process described above should be repeated for each actuator. When using a 2-fold push button, if the right rocker should be linked with the right rocker of a radiocontrolled actuator, the above procedure should be repeated, whereby the sending of the connection telegram must now be triggered by the toggling of DIL switch K2 (Diagram L). J3 Siemens G wave UP 560, 6 pages Technical Manual utomation and Drives Group Electrical Installation Technology Siemens G 2005 Update: P.O. ox , D Regensburg /5
6 Transmitter ctuator 230V wave UP 560 5WG n unlimited number of radio-controlled actuators can be operated remotely via the rockers of a transmitter actuator 230V wave. Switch and dimmer inserts can be operated together. The common operation of dimming and shutter functions is however only possible via scenes. Diagram L Changing the operation mode of the actuator (Diagram M) 1. Set the required actuator mode via F1 and F2 (nomal operation or time switch mode with 1, 5 or 15 minutes) 2. Switch the transmitter actuator to the special function via K3. (selected operation mode is adopted, LED flashes slowly). 3. ll the DIL switches are reset to OFF. Connecting the actuator with another transmitter (Diagram M) 1. Set the required actuator mode via F1 and F2 (normal operation or time switch mode with 1, 5 or 15 minutes) 2. Switch the transmitter actuator to the special function via K3 (selected operation mode is adopted, LED flashes slowly). 3. Trigger the learning telegram on the other transmitter (LEDs on the other transmitter and on the transmitter actuator first flash quickly and are then extinguished). 4. Set all DIL switches of the transmitter actuator to. Diagram M Linking the left rocker with its own actuator (Diagram N) 1. Set the required actuator mode via F1 and F2 (normal operation or time switch mode with 1, 5 or 15 minutes) 2. Switch the transmitter actuator to the special function via K3 (selected operation mode is adopted, LED flashes slowly). 3. Set the switch function or scene control via F1 to F3 (all other functions are not permitted) 4. Switch DIL switch K1to. 5. Reset all the DIL switches to Diagram N Deleting a link via radio: The deletion of a connection is carried out by a new assignment (see Connection via radio control ). Master reset (Resetting the device to the supplied state, Diagram O) Prerequisite: No other radio-controlled device may be switched to the special function. 1. First set the DIL switches F1 to F3 and then the DIL switches K1 to K3 to and wait 10 seconds. 2. Reset all the DIL switches to. Once all the DIL switches have been toggled the LED of the transmitter flashes quicker and quicker and is extinguished after approx. 10 seconds. ll the previously stored associations and connections are then deleted. If one of the DIL switches will be switched to before the deletion of the LED the master reset will be stopped and all previous associations will be retained. General Notes Diagram O The operating instructions should be handed over to the customer. ny faulty devices should be returned to the local SIEMENS office. Should you have any further queries about this product, please contact our Technical Support Department: +49 (0) # +49 (0) ! [email protected] h Technical Manual wave UP 560, 6 pages Siemens G utomation and Drives Group Update: Siemens G 2005 Electrical Installation Technology P.O. ox , D Regensburg /6
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI
Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI OSRAM GmbH Hellabrunner Str. 1 D-81536 Munich Tel.: +49 (0) 89 6213 0 Fax: +49 (0) 89 6213 2020 Customer Service Center (KSC)
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
Product and Application Description
Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
Inwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
KNX Gateway RGK02-5023E-01
KNX Gateway RGK02-5023E-01 Table of contents Page 1 General Information 1.1 Technical data 5 1.2. Intended Use 6 1.3 Specifications 6 1.4 Compatibility 6 1.5 Scope of delivery 6 2 Information about the
Operating instructions IV / 2007
General Operating instructions IV / 2007 Contents General Installation Application and function Application and function... 2 Safety information... 2 Design and dimensions... 3 Wiring diagram... 3 Installation
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
QFP910. Water detector. Building Technologies. CE1N2732en. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
Push button 3gang standard flush-mounted 751633xx
Documentation Product name: Push button 3gang standard Design: device (up) ETS search path: Push button / Push button 3gang / Push button 3gang standard Functional description: The push button 3gang standard
Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2
Installation and Operating Manual p. 23 Radio push button 2 channel: HM-PB-2-WM55-2 1. English edition 10/2013 Documentation 2013 eq-3 Ltd., Hong Kong All rights reserved. No parts of this manual may be
TYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel
Installation and User Guide TYXIA Wireless receiver TYXIA RF 642-1 channel DELTA DORE Bonnemain - 35270 COMBOURG - France E-mail : [email protected] Unit compliant with the requirements of directives:
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Light scene push button 8gang comfort flush-mounted 751688xx
751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1
Product manual ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes
B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x
B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with
Operating instructions II / 2004
Operating instructions II / 2004 Light and presence sensor TOUCH DIM LS/PD LI OSRAM GmbH Costumer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany www.osram.com www.osram.de Tel. : (+49)
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
RRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8
ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8 Quick Start A This device is a Z-Wave Actuator. Triple click one of the buttons on the device will include the device.
Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx
756627xx, 756637xx, 756657xx Documentation Product name: Push button 2-, 3-, 5- gang RTR + display Design: UP (flush-mounting type) ETS search path: Push button / Push button xgang / Push button xgang
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
Tebis application software
Tebis application software Input products / ON / OFF output / RF dimmer Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices WYC81xQ
Busch-Watchdog Presence EIB Type: 6131-74-102-500
Type: 6131-74-102-500 Contents Technical data 2-2 Application programs (List) 2-3 Circuit diagrams 2-3 in combination with Bus coupler FM (6120-102): Switch Value Cyclic Monitoring /3 2-4 Switch Value
QFP910. Water detector. Building Technologies. CE1N2732en 2016-03-01. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011
, 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
Inwall Room Temperature Unit
Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall
RY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions
DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Power Socket (2 Gang)
Version 2.1 Power Socket (2 Gang) Model No. LW270 Instruction Manual Connect Series www.lightwaverf.house EC DECLARATION OF CONFORMITY Responsible Authority: LightwaveRF PLC, Innovation Campus Birmingham
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
Danfoss Link Mobile Phone Butler
MAKIG MODER LIVIG POSSIBLE Installation Guide www.heating.danfoss.com Table of Contents 1 Introduction... 3 2 Installation... 3 3 Interfaces... 4 4 Wiring... 4 5 SMS Commands... 5 6 Technical Specifications...
Stove Guard Kit User Manual
Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent
3x cinch/s-video socket Order no.: 33 1532 xx. USB/3.5 mm audio socket Order no.: 33 1539 xx. VGA socket Order no.: 33 1540 xx
3x cinch/s-video socket Order no.: 33 1532 xx USB/3.5 mm audio socket Order no.: 33 1539 xx VGA socket Order no.: 33 1540 xx VGA socket with screw-in lift terminals Order no.: 33 1541 xx High definition
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
Building Service Management System instabus EIB
Training & Didactic Systems Building Service Management System instabus EIB Catalog WA2E/07.01 Catalog WA2E/07.01 Table of Contents Page Introduction to instabus EIB 4 Configuration Proposals for instabus
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
Air damper actuators
4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
ABB i-bus EIB Logic Module LM/S 1.1
Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
ABB i-bus KNX SA/S Switch Actuators Product Manual
ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional
IN-OUT Thermometer with Cable Free Sensor and Clock
IN-OUT Thermometer with Cable Free Sensor and Clock MODEL: RAR232 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RAR232 In-Out Thermometer with 433MHz cable free sensor and calendar
KNX Powerline PL 110. KNX Association
KNX Powerline PL 110 Table of Contents 1 Introduction...3 2 Standardisation...3 3 Transmission Process...4 3.1 Phase Coupling...5 3.2 Telegram Transmission...6 3.2.1 Training Sequence...6 3.2.2 Preamble
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011
Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Z-Wave.Me Wall Controller
Z-Wave.Me Wall Controller ZME_06443: Wall Controller Firmware Version 1.1 1 General Information about Z- Wave Safe: Generally radio systems build a direct link between the transmitter and the receiver.
Transmitter Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso
Transmitter Speed 1 9 3 5 0 Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso E L S Tr a n s m i t t e r S p e e d M a n u a l 0 2. 0 2. 2 0 1 0 / / 7
Battery Wall Controller. Manual
Battery Wall Controller Manual 009303 Battery Wall Controller Manual Quick Start... 2 Product Description... 3 Installation Guidelines... 3 Behavior within the Z-Wave Network... 4 Operating the Device...
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
basicdim DGC Compact control module
luxctrol lighting control sstem DGC Compact control module Product description Compact dimensions for luminaire installation For up to 0 DSI or LI ballasts ( per output channel) LI IN input LI/DSI output
contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control
Wireless Control Systems Accessories Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Accessories Programming Switching & Dimmer Functions
Relés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6
L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, UK. Tel: +44 (0)1527 406800 Fax:
500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1
Product Manual ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Intelligent Installation Systems This manual describes the function of the EIB monitoring module EUB/S 1.1 with the Application program
Business/ Home GSM Alarm System
Business/ Home GSM Alarm System BUSINESS/HOME GSM ALARM SYSTEM POWER STATUS RECORD SIGNAL User Manual Profile For a better understanding of this product, please read this user manual thoroughly before
EBDSPIR-PRM, EBDSPIR-PRM-IP
Product Guide EBDSPIR-PRM, EBDSPIR-PRM-IP Ceiling PIR presence/absence detector Overview The EBDSPIR-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads with optional
Installation & User Manual Radio Remote rev1.0.3
EN Installation & User Manual Radio Remote rev1.0.3 RC-20E RC-21E RC-22E RC-23E SLEIPNER MOTOR AS P.O. Box 519 N-1612 Fredrikstad Norway Tel: +47 69 30 00 60 Fax: +47 69 30 00 70 www.side-power.com [email protected]
Charge Controller CC611/CC612 Preliminary datasheet
Preliminary datasheet Preliminary datasheet CC61x_D00xxx_00_D_XXE_preliminary/04.2015 Product description The ender charge controller CC611 is the main component of a charging point and is designed for
HCE80/HCC80/HCE80R/HCC80R
HCE80/HCC80/HCE80R/HCC80R UNDERFLOOR HEATING-ZONEING CONTROLLERS PRODUCT DATA FEATURES Easy and fast installation because the new wiring design Pluggable terminals for fast wiring connection because clamp
13 SERIES. Electronic step relays 10-16 A 13.81 13.91
13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring
BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
Heating Controller. Building Technologies HVAC Products
2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or
Getting started with
PART NO. CMA113 MADE IN CHINA 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp Getting started with Electricity consumption monitoring single phase for homes and some smaller light commercial
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
RVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S 2.300.2. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX Universal Dim Actuator, MDRC UD/S 2.300.2 Intelligent Installation Systems ABB UD/S 2.300.2 Universal Dim Actuator, MDRC This manual describes the function of the Universal
Type: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
Operating Instructions. Room temperature controller
Operating Instructions 1. Area of application The room temperature controller is used to regulate the temperature in closed rooms such as flats, schools, function suites, workshops, etc. Safety instructions
ABB i-bus KNX Security Terminals MT/U 2.12.2, MT/S 4.12.2M and 8.12.2M Product Manual
ABB i-bus KNX Security Terminals MT/U 2.12.2, MT/S 4.12.2M and 8.12.2M Product Manual Contents Contents Page 1 General 3 1.1 Use of the product manual...3 1.1.1 Structure of the product manual...3 1.1.2
1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions
Compact presence detector Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause
I STAR COMPUTER CO., LTD
I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON
Fibaro electronic modules are smallest devices of the type in the World and can be installed in all standard wall switch boxes,
Fibaro Z-Wave modules: Compatible with any Z-Wave home automation system, Fibaro electronic modules are smallest devices of the type in the World and can be installed in all standard wall switch boxes,
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
Actuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX Data Logging Unit BDB/S 1.1 Intelligent Installation Systems ABB This manual describes the function of the Data Logging Unit BDB/S 1.1. Subject to changes and errors excepted.
ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1
Product Manual ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1 Intelligent Installation Systems This manual describes the function of the Switch
Unica for KNX system 226
Unica for KNX system 6 P117504 Greater flexibility and comfort, better energy efficiency with KNX More and more electronic appliances are needed for modern comfortable homes that contain everything from
5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
Time functions. Functions of the relay. instabus EIB Application program description. September 2001. 12 A1 Binary 510D01
September 2 2 A Binary 5D Product family: Product type: Manufacturer: Output Binary output, -fold Siemens Name: Load switch UP 5 Order no.: 5WG 5-2AB Functional description Using the application program
PXM20-E. Operator unit DESIGO PX
9 234 DESIGO PX Operator unit PXM20-E Network-compatible operator unit for viewing and operating one or more DESIGO PX automation stations. High-grade display with adjustable contrast Simple key operation
MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL
Centralized On-Off Remote Controller MC-821SC-E [FOR INSTLLER] INSTLLTION MNUL English [ [ π À À π ] E XEIPI IO O H IøN E KT T H [ [MONTÖR Ç N] MONTJ ELK TBI ÏÏËÓÈÎ [ДЛЯ УСТАНОВИТЕЛЯ] РУКОВОДСТВО ПО УСТАНОВКЕ
