LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6
|
|
|
- Charla Mitchell
- 10 years ago
- Views:
Transcription
1 L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ mm - Resolution typ. 0.1 mm - Integrated interference filter and red light filter - CCD line detector with 512 pixel (1024 subpixel) - RS232 interface and Windows user interface - 2 digitals inputs, 2 digital outputs - 1 analog output ( V, optionally additional output mA) - Switching state indication via 4 LEDs (2x red/grn, 2x yel/grn) - Sturdy aluminium housing suitable for industry - Scratch-resistanct optics cover made of glass Design Product name: L-LAS-LT-165-CL L-LAS-LT-165-CL-4/20 (incl. Windows software L-LAS-LT-Scope) Sturdy aluminium housing, anodized in blue 4/20 = additional analog output ( mA) Mounting holes Receiver optics Transmitter optics LED green (ok): Measuring value within tolerance window LED yellow: Power LED (multifunctional) LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold 4-pole fem. conn. Binder Series 707 (connection to RS232) cab-las4/pc or cab-las4/usb 8-pole fem. connector Binder Series 712 (connection to PLC) cab-las8/sps or cab-las8/sps-w Page 1/6
2 Technical Data Model Laser Reference Measuring Resolution distance range Reproducibility L-LAS-LT-165-CL L-LAS-LT-165-CL-4/20 Semiconductor laser, 670 nm, DC-operation, 1 mw max. opt. power, laser class 2 acc. to DIN EN The use of these laser sensors therefore requires no additional protective measures. approx. 165 mm typ. 65 mm mm typ. 0.1 mm typ. ± 0.1 mm L inearity (to be defined yet) Laser line geometry typ. 2 mm x 3 mm Optical filter Interference filter, red light filter RG630 A nalog output (ANA) 1x voltage output ( V) 1x voltage output ( V) 1x current output ( mA) Digital outputs (OUT0, OUT1) Digital inputs (IN0, IN1) Voltage supply Sensitivity setting Laser Current power correction consumption OUT0: (-) Measuring value < lower tolerance threshold OUT1: (+) Measuring value > upper tolerance threshold pnp bright-switching/npn dark-switching or pnp dark-switching/npn bright-switching, adjustable under Windows, 100 ma, short-circuit proof IN0: External trigger IN1: Teach/Reset (double function) Input voltage +Ub/0V, with protective circuit +15VDC VDC adjustable under Windows via PC adjustable under Windows via PC typ. 200 ma Enclosure rating Electronics: IP64, optics: IP67 Operating Storage Housing temperature range temperature range material -10 C C -20 C C Aluminium, anodized in blue H ousing dimensions LxWxH approx mm x 65 mm x 20 mm (without flange connectors) Type of connector Connecting cable LED indication (4x two-color LED) 2x two-color-led 8-pole circular fem. connector type Binder 712 (PLC/Power) 4-pole circular fem. connector type Binder 707 (PC/RS232) Connection to PC: cab-las4/pc or cab-las4/pc-w or cab-las4/usb Connection to PLC: cab-las8/sps or cab-las8/sps-w red/green and 1x two-color-led yellow/green for tolerance band monitoring: red (+) = Measuring value > upper tolerance threshold red (-) = Measuring value < lower tolerance threshold green (ok) = Measuring value within tolerance window 1x two-color LED yellow/green (multifunctional): EMC test acc. to DIN EN yellow = Power indication Measuring Max. frequency switching current typ. 500 Hz 100 ma, short-circuit proof I nterface RS232, parameterisable under Windows O utput polarity Bright-/dark-switching, can be switched under Windows Page 2/6
3 Dimensions 165 All dimensions in mm Page 3/6
4 Connector Assignment Connection to PLC: 8-pole fem. connector Binder Series 712 Pin: Color: Assignment: 8 1 white GND (0V) 7 2 brown VDC (+Ub) 3 green IN0 (EXT TRIGGER) 4 yellow IN1 (TEACH / RESET) 5 grey OUT0 (-) 6 pink OUT1 (+) 7 blue GND (0V) or in case of -4/20: ANA (current mA) 8 red ANA (voltage V) cab-las8/sps-2m or cab-las8/sps-w-2m (angle type 90 ) 1 cab-las8/sps-... (length max. 25 m, outer jacket: PUR) Connection to PC: 4-pole fem. connector Binder Series 707 Pin: Assignment: VDC (+Ub, OUT) 2 GND (0V) 3 Rx0 4 Tx cab-las4/pc-2m or cab-las4/pc-w-2m (angle type 90 ) alternative: Connection via USB-interface at the PC: cab-las4/pc-... (length max. 15 m, outer jacket: PUR) cab-las4/usb-0,5m cab-las4/usb-1m cab-las4/usb-2m (incl. driver software) cab-las4/usb-... (length max. 5 m, outer jacket: PUR) Page 4/6
5 LED Display LED display: (+) (-) Power (ok) LED red (+): Measuring value > upper tolerance threshold (OUT1) LED yellow: Power LED (multifunctional) LED red (-): Measuring value < lower tolerance threshold (OUT0) LED green (ok): Measuring value within tolerance window Laser Warning The laser line sensors of L-LAS Series comply with laser class 2 according to EN The use of these laser transmitters therefore requires no additional protective measures. The laser line sensors of L-LAS Series are supplied with a laser warning label. LASER RADIATION DO NOT STARE INTO THE BEAM CLASS II LASER PRODUCT Page 5/6
6 Parameterization Windows Software L-LAS-LT-Scope: The L-LAS-LT sensor can be easily parameterised with the Windows user interface. For this purpose the sensor is connected to the PC with the serial interface cable cab-las4/pc. When parameterisation is finished, the PC can be disconnected again. Windows user interface: With the help of the L-LAS-LT-Scope software the following settings can be made at the sensor: - Setting of laser power and type of automatic power correction - Polarity of digital outputs - Different evaluation modes - Start of the teach process by software button - Setting of tolerance ranges for monitoring the measured value Furthermore, various numerical and graphical measured quantities can be visualized with the L-LAS-LT-Scope software. For example, the raw data of the CCD line sensor can be displayed graphically and numerically. Page 6/6
L-LAS-TB-CL serie. laser light curtains for inline measuring tasks
L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output
Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes
SI-COLO Series SI-COLO2-LWL-HAMP-COL4 - Big measuring range: typ. 25 mm... 40 mm (with optical fiber and attachment optics KL-14 or KL-17) - Large assortment of optical fibers available (reflected or transmitted
SPECTRO Series SPECTRO-3-FIO-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (cf. p. 11-13)
SPECTRO Series - Big working range: typ. mm... 5 mm (depends on the fiber optics used and attachment optics) - Big assortment of fiber optics available (reflected light or transmitted light operation)
Instruction Manual. optocontrol 1220-28
Instruction Manual -28 Non-contact laser micrometer MICRO-EPSILON Eltrotec GmbH Heinkelstraße 2 73066 Uhingen / Germany Tel. +49 (0) 7161 / 98872-300 Fax +49 (0) 7161 / 98872-303 [email protected]
RLS Series RLS-GD-15. Design. RLS-GD Series Gloss Detection Sensors. Accessories: Product name: RLS-GD-15 RLS-GD-15-HP (High Power)
RLS Series RLS-GD-15 Gloss Detection - Insensitive to outside light due to clocked white light - 2 receivers (15, 60 ) and reference - Storing of up to 31 gloss degrees - Tolerance adjustable for each
SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
sensors Miniature Sensors - S100 The universal miniature photoelectric sensor
Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and
Laser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
REGTRONIC OPERATING INSTRUCTIONS
REGTRONIC OPERATING INSTRUCTIONS 1.FEATURES Electrical connection: M12 8-pin connector Preset pressure range 0.05-10 bar with possible full scale regulation. 10 100 mbar adjustable deadband Supply pressure:
SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
W150: Miniature photoelectric switch series with completely integrated electronics
Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
Series 7500 Torque Sensor
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement
Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
Series 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
How To Power A Schen
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection
Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!
SMART CAMERA SENSORS SMART CAMERA SENSOR FOR VISUAL INSPECTION AND IDENTIFICATION
SMART CAMERA SENSOR FOR VISUAL INSPECTION AND IDENTIFICATION SMART CAMERA SENSORS Cost-effective High performances CMOS 640x480 image sensor Digital I/O RS3 or RS485 Ethernet port for external PC configuration
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems
WLL 0(T) Photoelectric switches Photoelectric switches with fibre-optic cable Proximity mode Photoelectric switches with fibre-optic cable Through-beam mode Photoelectric switches WLL 0(T), fibre-optic
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
TECHNICAL DATASHEET Incremental Encoder RI 80-E
Incremental 30-45 hollow shaft Rugged mechanical design Unbreakable disc Integrated diagnostic system Wide voltage range DC 5-30 V Isolated shaft NUMBER OF PULSES 1024 / 2048 / 2500 / 4096 / 5000 / 10000
Guideline Laser Series
Guideline Laser Series Highly visible alignment laser for visually demanding surfaces Red / Green long visible lines Equal brightness across length of the line Uniform Line (no fading at ends of the line)
photoelectric highlights www.automation.datalogic.com
photoelectric miniature sensors S8 series The new S8 series of compact sensors offers excellent detection performances, usually associated with sensors that have larger dimensions and a higher price. The
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space
CC-Link Communication Unit * FASTUS is a product brand of Optex FA. Monitor and control the sensors through network supported Remote controlling of fiber sensors Reduces wires and saves space OPTEX FA
VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
Color Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig
Through hollow shaft Ø 5 bis 4 mm Outside diameter only 76 mm Easy installation by means of clamping ring front or rear Operating temperature up to 00 C Applications: motors, printing machines, lifts NUMBER
TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T
Universal industry standard encoder Up to 40 000 steps with 0 000 pulses High signal accuracy Protection class up to IP67 Flexible due to many flange and configuration variants Suitable for high shock
Electrical connection
(I)GSU 14B Ultrasonic Label Fork Dimensioned drawing Part No. 501 09234 4mm 12-30 V DC 4 m/s Ultrasonic forked sensor for universal application Large mouth width, hence also suitable for booklets or fan-fold
DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters
Description DVI (Digital Visual Interface) recently becomes an popular interface between monitor and PC. Electrical signal limits the transmission length and quality. APAC DVI extender helps DVI to transmit
Givare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
Liquid Level Limit Switch liquiphant T FTL 20
Technical Information TI 64F/4/ae Liquid Level Limit Switch liquiphant T FTL 0 Level limit switch for liquids Applications The Liquiphant T FTL 0 is a level limit switch for virtually any kind of fluid
Operating instructions Optical distance sensor O1D100 O1D103 704991 / 00 08 / 2012
Operating instructions Optical distance sensor UK O1D100 O1D103 704991 / 00 08 / 2012 Contents 1 Preliminary note4 1.1 Symbols used 4 1.2 Warning signs used 4 2 Safety instructions 4 3 Functions and features
technical data (according to IEC 60947-5-2)
Photoelectric sensors: Series 3#30 & 3#31 ü Complete miniature sensor series mm in rugged Crastin housings ü Shock & vibration resistant due to fully vacuum-potted electronics ü Diffuse sensors with precise
LwLVision-USB 2.0. Installation Guide
LwLVision-USB 2.0 Installation Guide About this manual This manual has been carefully compiled and examined to the state-of-the-art. G&D neither explicitly nor implicitly takes guarantee or responsibility
PLUTO Safety-PLC. Manual Absolute Encoders
PLUTO Safety-PLC Manual Absolute Encoders English v6a 2TLC172006M0206_A Table of contents: 1 General... 3 1.1 Reaction time... 3 1.2 Safety parameters... 3 2 Electrical... 4 2.1 Separation with Gateway
Basic Specifications. Electrical. EPSON Perfection 3170. Color EPSON MatrixCCD TM line sensor. device Effective pixels
Scanner Parts Document table Power cord Document cover Transparency unit (TPU) under lid Web Transparency unit (TPU) connector TPU indicator light e-mail Carriage and lamp (in the home position) USB port
Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm
Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications
Vibration Monitoring System Adash 3600
" User's guide Application: Vibration Monitoring System Adash 3600! Vibration diagnostics, monitoring and protective on-line system! On-line vibration monitoring system of engines, fans, pumps, gearboxes,
Digital display DA 48
Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital
Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:
Oil & Gas / Heavy Industry EX-Proof Stainless Steel Shaft Encoder - Ø 68 mm Shaft - Ø 10 mm to Ø 5/8 inch Resolution up to 10,000 ppr IP 66 (IP 67 option) ATEX certified EX-Proof IECEx certified EX-Proof
Contents & P-LCD Modules Cross Reference Table
Contents & P-LCD Modules Cross Reference Table Contents Contents & P-LCD Modules Cross Reference Table Introduction & Standard P-LCD Modules Modes Custom P-LCD Modules Standard Design P-LCD Modules (Character
Adjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
LUT Luminescence scanners: Seeing what no-one else can
LUT Luminescence scanners Luminescence scanners LUT Luminescence scanners: Seeing what no-one else can Special features: A semi-conductor light source is used in the LUT series no lamp change required.
intelligent solutions
Lichtschranken W 8- Photoelectric Baureihe switches WL - Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 8-: Integrated stateof-the-art technology
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
Relative and absolute pressure switch type 529
Relative and absolute pressure switch type 529 Pressure range -1... 0 60 bar The compact type 529 pressure switch is based upon the Huba Control developed unique ceramic technology used for the last 20
Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.
ZFX-C/25-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection via
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive
Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol
Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]
Emergency lighting units EM powerled
M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year
Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30
Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30 Euronorm thermoplastic polyester housing, cylindrical Diameter: M 12, M 18, M 30. Sensing distance: 2 to 15 mm
VISION. Data VS2 DATAVS2
DATAVS2 The DataVS2 vision sensor series presents all the characteristics to solve machine vision applications in a flexible and intuitive way. DataVS2 is a completely embedded device: the optic, the LED
Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs
E L E K T R O N I K Appliance Description Programmable safety center FPSC Fiessler Programmable Safety Center Flexible Hard- and Software concept Available with a safe bus system or/and two counter inputs
Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage
Description Supports DALI interface driver Programming Supports 0-10V Programmable Driver Programming Supports Other Controllers (TDD-ANPNx, SDD-AAPNx) Off-line programming capability Auto programming
Option field bus: without bus with profibus DP. Design-Index (Subject to change)
Amplifier / controller cards ED1 Digital amplifier / controller card ED1 for 1 or 2 proportional solenoids 4 analogue inputs, of which 2 for differential inputs 8 digital inputs Card setting via PC, multi-function
Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004
Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical
Temperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology
Tilt switches MEMS technology, one or two axis N3 / N4... + long lifetime and highly reliability due to mechanism-free MEMS technology + combinable output signals + one or two axis measurement + tilt range
Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012
Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Contents 1 Preliminary note 3 1.1 Symbols used 3 1.2 Warning signs used 3 2 Safety instructions
crm+25/d/tc/e Extract from our online catalogue: Current to: 2015-10-26
Extract from our online catalogue: crm+25/d/tc/e Current to: 2015-10-26 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E [email protected]
More Precision. optoncdt // Laser Triangulation Displacement Sensors
More Precision optoncdt // Laser Triangulation Displacement Sensors 2 optoncdt Laser triangulation sensors optoncdt - Non-contact and wear-free - Large stand off - Tiny measuring spot for small targets
Cable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
550-xx05-004. 5mm LED CBI. Circuit Board Indicator Square Back Housing, Quad Block. 5 5 0 - x x 0 5-0 x 4
5mm LED CBI Circuit Board Indicator Square Back Housing, Quad Block 5.9 [.235] 3.8 [.145].35 [.250].35 [.250] 25 [.985].35 [.250] Red Cathode for Red/Green Bi-Color Cathode for /Green Bi-Color RECOMMENDED
DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters
Description DVI (Digital Visual Interface) recently becomes an popular interface between monitor and PC. Electrical signal limits the transmission length and quality. APAC DVI extender helps DVI to transmit
Absolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.
ZFX-C10/15-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection
Technical Data Sheet OPUS A6 STANDARD Basic TDS OPUS A6sB, 02.10.2012
Technical Data Sheet OPUS A6 STANDARD Basic TDS OPUS A6sB, 02.10.2012 OPUS A6 STANDARD Basic Landscape OPUS A6 STANDARD Basic Landscape/Portrait 1 Order Numbers OPUS A6 STANDARD Full Wachendorff Projektor
Unidirectional Transmitter/ Receiver Units Introduction
Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Operating instructions Switching amplifier for fibre optics. OBF5xx 704876 / 00 08 / 2010
Operating instructions Switching amplifier for fibre optics OBF5xx 70876 / 00 08 / 00 Contents Preliminary note. Symbols used Functions and features. Applications Installation. Attaching the fibre optics
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
D/N VANDAL RES. VARI-FOCAL IR DOME CAMERA
D/N VANDAL RES. VARI-FOCAL IR DOME CAMERA PIH-0746XW/0746XS INSTRUCTION MANUAL IMPORTANT SAFEGUARDS CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE
To Purchase This Item, Visit BMI Gaming www.bmigaming.com 1-800-746-2255 + 1-561-391-7200. Operation Manual
Operation Manual 90MAN 01 B Copyright 2008 Patent Pending All Rights Reserved Table of Contents Game Play 3 Game Set up 4 Technical Description 5 Programming 6 10 Error Codes 9 Electronic Components 11
ViZion Installation Guide
ViZion Installation Guide v2.0 1 ViZion Installation Guide Table of Contents Inventory Hardware Setup Understanding Synchronization Cable Begin by taking an inventory of the required equipment DR Unit
VOICE RECORDING SYSTEM ISDN PRI / BRI
Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs
857 Micro Sensor General terms and conditions... P.1 Related Information Glossary of terms / General precautions... P.1019 / P.1027 Sensor selection guide... P.11~ / P.833~ About laser beam... P.1025 ~
Product Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: [email protected] Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4