FIRE RESISTANT CABLE CONSTRUCTION OF CABLES



Similar documents
The Quality Connection. BETAflam Fire Resistant Safety Cables

Fire Resistant Cables

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.

FIRE RESISTANT CABLES FP200 GOLD

INTERNATIONAL STANDARD

Fire Performance Standard

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables /15 kv XLPE insulated cables /20 kv XLPE insulated cables 35

Gulf Cable & Electrical Ind. Co.

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

WHITE PAPER Fire & safety performance standards

Catalogue Câbles d Energie

Power and Wiring Cables

ScottishPower Distribution Cables & Equipment. Metal Theft

CONFLEX ELECTRIC CABLE

VIPERFLEX ELECTRIC CABLE

Marine & Shipboard Cable JIS C 3410(1999) IEC , 353, 354, 376

Global cable expertise for rolling stock

Building Cables and Wires

Gulf Cable & Electrical Ind. Co.

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

Flexible and safe solutions, for decades. Cables for alarmand safety systems

Important Information: Complete Terms and Conditions are printed on sales invoices

KNOW YOUR OPTIONS: 230 KV POWER CABLES

MEDIUM VOLTAGE POWER CABLES

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

The Handbook 2013 EDITION

International Electrotechnical Commission Standards

CLEVELAND CABLE LOCATIONS

Section kv Power Cables

RADOX railway cables acc. to EN and EN Edition 2009

Speciality Cabling Solutions

MEDIUM VOLTAGE CABLES Up to and including 36 KV

MV CABLE TYPE C

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters

CURRENT RATINGS MORE THAN A CABLE

INTERNATIONAL STANDARD

XLPE Land Cable Systems User s Guide. Rev 5

100% EMI Emission Containment

The Quality Connection. BETAflam Fire safety cables

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

COAX Cables Radio Frequency Cables

APPLICATION ORIENTED DESIGN OF CABLES

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

UGVCL/SP/591/11KV HT AB CABLE

Fault location on power cables. Fault location on power cables

The Instrumentation Cable Experts

Technical cable guide

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies

Comparative study for cables and busbars

Caledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5

The proof is here!! Ron Goethals, Philadelphia; June 18, 2014

LOW VOLTAGE POWER CABLES

British Standards BSEN :2005

The most important matter is to select the right product based on the environment in which it will be installed and on its use or application.

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

Copper Cables CONNECTIVITY & CABLING SYSTEM

Commercial Coaxial Cable

TABLE OF CONTENT

Current Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69

Flexible cables for submersible products

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

EXAMPLE OF RELEVANT STANDARDS

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

Fire Resistance and Safety in Case of Fire

Tri-Rated Flexible PVC Equipment Wire

Communication, Signal & Data Cables

ISO 9001 ISO CABLES AND WIRES CATALOGUE 2008

HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI

Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing

Removal of EP SP High Voltage Cable

David O Brien, CMP Products (David.OBrien@cmp-products.com)

Network Standard Advice No. 1420C 9/6/2011

Cable Size Selection for Energy Efficiency

APR 2016 Rev M

White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection

Automotive Wire and Cable Products

Specification SFTP CAT6 Network Cable 23AWG CU

The Quality Connection. BETAflam Safety cables for highest demands

HARAX circular connector

EDS KV TRIPLEX CABLE

Instrumentation Cable Power Cable Assembly Solutions...32

Festoon 715 P PUR cable for flexible application in festoon systems

B05: Cable protection and sheathing

ROLLING STOCK CABLES

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

6 ELECTRICAL PARAMETERS

Two Test Methodologies for Evaluating the Resistance to Electrical Arcing Properties of Polymeric Materials for use in Automotive 42 V Applications

Comprehensive safety concepts for building applications

Industrial Cable Solutions for Variable Frequency Drives

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT Phone: Fax:

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

CAVEL VS80205 MADE IN ITALY 1000 V

Medium-voltage cables for reliable windpark infrastructure

Fibre optic cables MDIC LSZH

Transcription:

FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the use of fire resistant and non-halogenated cables. These cables provided the following features : Fire resistance Long-term circuit integrity in a fire Low smoke and toxic gas emissions Flame retardant properties Zero halogen gases Ease and low cost of installation Fire Resistant cables are used, where required by local fire codes, in the wiring of : Fire resistant safety circuits Public address and emergency voice communication systems in high-rise buildings Control and instrumentation services in industrial, commercial and residential complexes High-temperature installation conditions CONSTRUCTION OF CABLES UCMB's Fire Resistant cables have been developed to maintain circuit integrity in a fire and to ensure maximum safe evacuation of personnel with no detrimental effects like toxic gases or smoke. The Fire Resistant cables are constructed in the following typical format : Stranded Annealed Copper Conductor Glass Mica Tape Fire Resisting Barrier XLPE/EPR/SiR/EVA/PE/PVC Primary Insulation Low Smoke Halogen Free (LSOH) or Flame Retardant PVC Sheathing Fire Resistant cables may be single-core or multi-core constructions. The insulation material can be elastomeric materials (XLPE, EPR, SiR, or LSOH) instead of thermoplastic (EVA, PE or PVC) to meet stringent environment requirement.the cables may be armoured or braided, with or without metallic screened depending on our customer's specific application. UCMB provides PE, PVC or Low Smoke Halogen Free (LSOH) materials as outer sheath for marine and offshore application.

INTERNATIONAL STANDARD COMPLIANCE The Fire Resistant cables manufactured by UCMB complied with either one or combination of the specification as below : IEC 60331, BS 6387, SS 299 Fire Resistance Test IEC 60332, BS 4066, IEEE 383 Flame Retardant test IEC 61034, BS 7622, EN 50268 Smoke Emission Test IEC 60754, BS 6425 Halogen Content Test ASTM D 2863 Oxygen Index Test The Fire Resistant cables are categorized by a letter symbol (e.g. A) or series of symbols (e.g. CWZ) according to the requirements for fire resistance characteristics which they meet, the test temperature selected and the duration of the test for resistance to fire alone in according to BS 6387 as below : Requirement Symbol ( 1 ) Resistance to fire alone 650 C for 3 hours A 750 C for 3 hours B 950 C for 3 hours C 950 C for 20 minutes (short duration) S ( 2 ) Resistance to fire with water W ( 3 ) Resistance to fire mechanical shock 650 C X 750 C Y 950 C Z The following certifications / type test approvals obtained by UCMB : Sirim QAS Sdn Bhd Quality System Registration Certificate MS ISO 9001 Quality Management Systems Product Certification License Type Test Approval Fire Resistant cables to IEC 60331, IEC 60332-3, ASTM D 2863 Jabatan Bomba Dan Penyelamat Malaysia Fire Resistant cables to IEC 60331, IEC 60332, BS 6387 Singapore Institute Of Standards & Industrial Research Fire Resistant cables to SS 299, IEC 60331, IEC 60332, BS 6387

LOW SMOKE HALOGEN FREE ( OR FLAME RETARDANT PVC ) SHEATHED CABLE ( SINGLE CORE ) Cross Stranding Nominal thickness thickness overall weight conductor sectional number / diameter of of diameter of resistance area diameter insulation sheath of cable cable at 20 C 1 7 / 0.44 1.32 0.7 0.8 5.1 35 18.1 1.5 7 / 0.53 1.59 0.7 0.8 5.4 42 12.1 2.5 7 / 0.67 2.01 0.7 0.8 5.8 53 7.41 4 7 / 0.85 2.55 0.7 0.9 6.6 74 4.61 6 7 / 1.04 3.12 0.7 0.9 7.1 96 3.08 10 7 / 1.35 4.05 0.7 0.9 8.1 141 1.83 16 7 / 1.70 5.10 0.7 0.9 9.1 203 1.15 25 7 / 2.14 6.42 0.9 1.0 11.0 310 0.727 35 19 / 1.53 7.65 0.9 1.1 12.5 416 0.524 50 19 / 1.78 8.90 1.0 1.4 14.5 564 0.387 70 19 / 2.14 10.70 1.1 1.4 16.5 781 0.268 95 19 / 2.52 12.60 1.1 1.5 18.6 1050 0.193 120 37 / 2.03 14.21 1.2 1.5 20.4 1300 0.153 150 37 / 2.25 15.75 1.4 1.6 22.7 1600 0.124 185 37 / 2.52 17.64 1.6 1.6 25.0 1980 0.0991 240 61 / 2.25 20.25 1.7 1.7 28.1 2590 0.0754 300 61 / 2.52 22.68 1.8 1.8 30.9 3220 0.0601 400 61 / 2.85 25.65 2.0 1.9 34.6 4090 0.0470 500 61 / 3.20 28.80 2.2 2.0 38.3 5110 0.0366 630 91 / 2.98 32.78 2.4 2.2 43.1 6570 0.0283

LOW SMOKE HALOGEN FREE ( OR FLAME RETARDANT PVC ) SHEATHED CABLE ( MULTI CORES ) Cross Number Stranding Nominal thickness thickness overall weight conductor sectional of number / diameter of of diameter of resistance area cores diameter insulation sheath of cable cable at 20 C 1 2 7 / 0.44 1.32 0.7 1.6 10.1 104 18.1 1 3 7 / 0.44 1.32 0.7 1.6 10.6 125 18.1 1 4 7 / 0.44 1.32 0.7 1.6 11.5 150 18.1 1.5 2 7 / 0.53 1.59 0.7 1.6 10.7 120 12.1 1.5 3 7 / 0.53 1.59 0.7 1.6 11.3 148 12.1 1.5 4 7 / 0.53 1.59 0.7 1.6 12.2 178 12.1 4 2 7 / 0.85 2.55 0.7 1.6 12.7 188 4.61 4 3 7 / 0.85 2.55 0.7 1.6 13.4 243 4.61 6 2 7 / 1.04 3.12 0.7 1.6 13.7 237 3.08 LOW SMOKE HALOGEN FREE ( OR FLAME RETARDANT PVC ) SHEATHED CABLE ( WITH EARTH CONDUCTOR & MULTI CORES ) Cross Number Stranding Nominal thickness thickness overall weight conductor sectional of number / diameter of of diameter of resistance area cores diameter insulation sheath of cable cable at 20 C 1.5 2 + Earth 7 / 0.53 1.59 0.7 1.6 11.3 144 12.1 1.5 3 + Earth 7 / 0.53 1.59 0.7 1.6 12.2 174 12.1 4 2 + Earth 7 / 0.85 2.55 0.7 1.6 13.4 237 4.61 4 3 + Earth 7 / 0.85 2.55 0.7 1.6 14.6 296 4.61 6 2 + Earth 7 / 1.04 3.12 0.7 1.8 14.9 319 3.08 6 3 + Earth 7 / 1.04 3.12 0.7 2.0 16.6 416 3.08 10 3 + Earth 7 / 1.35 4.05 0.7 2.0 19.1 604 1.83 16 3 + Earth 7 / 1.70 5.10 0.7 2.0 21.5 857 1.15 25 3 + Earth 7 / 2.14 6.42 0.9 2.4 26.4 1330 0.727 35 3 + Earth 19 / 1.53 7.65 0.9 2.6 29.9 1770 0.524

XLPE INSULATED, STEEL WIRE ARMOURED, FLAME RETARDANT PVC SHEATHED CABLE Number Nominal Nominal Approx. Nominal Nominal Approx. Approx. of cross thickness diameter diameter thickness overall weight cores sectional of under of of diameter of area insulation armour steel wire sheath of cable cable mm² mm mm mm mm mm Kg / Km 1.5 0.7 10.0 0.9 1.8 15.4 409 2.5 0.7 10.7 0.9 1.8 16.1 456 4 0.7 11.7 0.9 1.8 17.1 540 6 0.7 12.3 0.9 1.8 17.7 583 10 0.7 14.7 1.25 1.8 20.8 875 16 0.7 17.0 1.25 1.8 23.1 1067 Two Core 25 0.9 19.1 1.6 1.8 25.9 1526 35 0.9 21.5 1.6 1.8 28.3 1839 50 1.0 24.2 1.6 1.8 31.0 2230 70 1.1 27.9 1.6 2.0 35.1 2869 95 1.1 31.6 2.0 2.1 39.8 3940 120 1.2 35.3 2.0 2.2 43.7 4700 150 1.4 39.7 2.0 2.3 48.3 5487 185 1.6 43.6 2.5 2.5 53.6 7078 240 1.7 49.6 2.5 2.7 60.0 8742 1.5 0.7 10.5 0.9 1.8 15.9 454 2.5 0.7 11.4 0.9 1.8 16.8 515 4 0.7 11.8 0.9 1.8 17.2 572 6 0.7 13.2 0.9 1.8 18.6 673 10 0.7 15.8 1.25 1.8 21.9 1029 16 0.7 18.1 1.25 1.8 24.2 1302 Three Core 25 0.9 20.6 1.6 1.8 27.4 1849 35 0.9 22.9 1.6 1.8 29.7 2258 50 1.0 25.7 1.6 1.8 32.5 2273 70 1.1 30.2 2.0 2.0 38.2 3962 95 1.1 33.5 2.0 2.2 41.9 4959 120 1.2 37.9 2.0 2.3 46.5 5913 150 1.4 42.6 2.5 2.5 52.6 7545 185 1.6 47.4 2.5 2.6 57.6 9085 240 1.7 53.3 2.5 2.8 63.9 11379 1.5 0.7 11.8 0.9 1.8 17.2 511 2.5 0.7 12.3 0.9 1.8 17.7 565 4 0.7 13.8 0.9 1.8 19.2 678 6 0.7 15.2 1.25 1.8 21.3 945 10 0.7 17.7 1.25 1.8 23.8 1223 16 0.7 19.1 1.6 1.8 25.9 1693 Four Core 25 0.9 23.1 1.6 1.8 29.9 2247 35 0.9 25.8 1.6 1.9 32.8 2820 50 1.0 28.7 1.6 2.0 35.9 3472 70 1.1 33.5 2.0 2.2 41.9 4919 95 1.1 38.7 2.0 2.3 47.3 6132 120 1.2 43.1 2.5 2.5 53.1 7964 150 1.4 47.7 2.5 2.6 57.9 9438 185 1.6 52.8 2.5 2.8 63.4 11388 240 1.7 59.5 2.5 3.0 70.5 14367