Section 5 161 kv Power Cables



Similar documents
KNOW YOUR OPTIONS: 230 KV POWER CABLES

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G

EDS KV TRIPLEX CABLE

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities

High Voltage Systems. Today. The history of cables

HIGH VOLTAGE XLPE CABLE SYSTEMS. Technical User Guide

XLPE Land Cable Systems User s Guide. Rev 5

100% EMI Emission Containment

Industrial Cable Solutions for Variable Frequency Drives

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

Network Standard Advice No. 1420C 9/6/2011

Gulf Cable & Electrical Ind. Co.

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables /15 kv XLPE insulated cables /20 kv XLPE insulated cables 35

UGVCL/SP/591/11KV HT AB CABLE

MEDIUM VOLTAGE CABLES Up to and including 36 KV

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

Removal of EP SP High Voltage Cable

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES

Exane 125 Drilling Rig and Commercial Marine Cable

APPLICATION ORIENTED DESIGN OF CABLES

Uptown Campus, Primary Electric Master Plan - Program Study State University of New York At Albany, SUCF Project No V.

MEDIUM VOLTAGE POWER CABLES

Cables, Cable Laying & Accessories Manual

Underground Cable Temperature Monitoring in the Real World

Fault location on power cables. Fault location on power cables

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

MV CABLE TYPE C

Communication, Signal & Data Cables

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

Session Five: Modern XLPE Materials for Extruded Energy Cable Systems

VIPERFLEX ELECTRIC CABLE

SECTION SIGNAL WIRE AND CABLE

Two different types of cables are used in primary airfield lighting circuits: - unshielded cables and - shielded cables

COAX Cables Radio Frequency Cables

Instrumentation Cable Power Cable Assembly Solutions...32

High Voltage Cable Systems

CONFLEX ELECTRIC CABLE

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

WIRE AND CABLE ENGINEERING GUIDE

Outside Telephone Cable

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

Specification SFTP CAT6 Network Cable 23AWG CU

Tri-Rated Flexible PVC Equipment Wire

6-36kV Medium Voltage Underground Power Cables. XLPE insulated cables

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

Commercial Coaxial Cable

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

345 kv Underground Report

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

Least Cost Cable System. Strategies to Reduce Cable and Infrastructure Costs When Transitioning to an All Conduit Systems

SECTION MEDIUM VOLTAGE CABLE

CABLE ACCESSORIES kv

International Electrotechnical Commission Standards

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

M. GELDON Brugg Kabel CZ. Ing. D. RÚŽEK PREdistribuce. Switzerland Czech Rep. Czech Rep. Czech Rep., Switzerland Germany

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

ACCESSORIES FOR HV CABLES WITH EXTRUDED INSULATION

Flexible cables for submersible products

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Radial Distribution Test Feeders

6 ELECTRICAL PARAMETERS

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

MICROCABLES. A complete vision of your connectivity needs. Catalogue

Fire Resistant Cables

General Calculations. Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE

INTERNATIONAL STANDARD

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

XLPE рower cables. 2 Modern solutions for power cables I Estralin HVC

How To Monitor Water Penetration In A Cable Screen

LOW VOLTAGE POWER CABLES

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

The Instrumentation Cable Experts

Standards Affecting a Premise T-1 Installation

3M Scotchcast Mine and Portable Cable Splice Kit

Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing

Installation and Application Guide. for 600V Conductors

Global cable expertise for rolling stock

with coloured cores and overall copper screen UL/CSA... 17

6000 Series Buccaneer

Standard Buccaneer - Ethernet

superconductors, while also working on integrating the new 2nd generation superconductors based on Y(RE)Ba 2 Cu 3 O X Ca 2

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

ScottishPower Distribution Cables & Equipment. Metal Theft

WIRE AND CABLE ENGINEERING GUIDE

Contents. All Rights Reserved

Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

The Quality Connection. BETAflam Fire Resistant Safety Cables

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

TECHNICAL SPECIFICATIONS OF 66 KV 1C 630 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE

Cable Tray Selection-

Power and Wiring Cables

KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET

Power Cable Splicing & Terminating. edited by Robert Goodman and William Osborn

Transcription:

Know Your Options: 161 kv Power Cable 61

material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper and aluminum conductors can meet your requirements, the more economical solution will be a function of the metal and the cable component costs Insulation thickness For cables with a radial moisture barrier, Southwire Standard Wall reduced insulation thicknesses within the stress limits in AEIC specification CS9 are recommended For applications requiring smaller cable diameters, specific designs are available upon request within the stress limits in AEIC specification CS9 Section 5 161 kv Power Cables Sheath material Copper and aluminum corrugated sheaths offer the best mechanical and moisture protection for your HV cable, and copper will provide better short circuit performance and improved connectability Composite laminate sheaths in both copper and aluminum that offer excellent protection against moisture ingress Jacket Standard outer jacket: extruded LLDPE with a co-extruded outer semi-conductive polyethylene layer for jacket integrity testing Halogen Free Fire Retardant (HFFR) compounds are available upon request for installations in cable trays and ventilated troughs 62

161 kv Power Cables 161 kv XLPE - Copper SW Standard Wall XLPE Copper Corrugated Sheath Cable Construction Reverse Concentric Stranded Copper, Compressed or MIlliken Super Smooth Shield Super Clean XLPE Insulation 690 mil XLPE minimum True Triple Extrusion and Dry Cured Firmly Bonded Insulation Shield Welded Copper Corrugated Sheath Polyethylene Jacket with Extruded Semi-Conductive Outer Layer Cable Data Voltage Characteristics (kv) Max Voltage Rating 169 BIL Rating 750 Temperatures ( o C) Nominal 90 Max. Emergency 105 Short Circuit 250 Minimum Installation -10 Design Characteristics Design Standards AEIC, IEC Typical Test Voltages 280 kv / 15 min. XLPE Loss Factor 0.0005 Relative Permittivity 2.3 63

Size in kcmil 1 750 1000 1250 1500 1750 2000 2500 3000 3500 4000 Dimensional Diameter Insulation Thickness Diameter over Insulation Diameter over Sheath Overall Jacket Diameter Nominal in 0.97 1.12 1.25 1.37 1.48 1.61 1.76 1.92 2.08 2.21 mm 24.7 28.5 31.8 34.8 37.6 40.9 44.7 48.8 52.8 56.1 mils 840 790 760 730 710 690 700 710 720 730 mm 21.3 20.1 19.3 18.5 18.0 17.5 17.8 18.0 18.3 18.5 in 2.77 2.82 2.89 2.95 3.02 3.08 3.36 3.52 3.72 3.87 mm 70.3 71.6 73.4 74.9 76.7 78.3 85.3 89.4 94.4 98.3 in 3.32 3.36 3.44 3.51 3.58 3.65 3.96 4.14 4.36 4.52 mm 84.3 85.4 87.5 89.2 91.0 92.7 100.7 105.2 110.6 114.9 in 3.60 3.64 3.72 3.79 3.86 3.93 4.24 4.42 4.64 4.80 mm 91.4 92.5 94.6 96.3 98.1 99.8 107.8 112.3 117.8 122.0 Total Weight lbs/ft 6.8 7.6 8.4 9.3 10.1 11.0 13.2 15.1 17.1 19.0 Min. Bending Radius (install/ perm.) Maximum Pulling Tension Typical Shipping Reel Size in 72/54 73/55 74/56 76/57 77/58 79/59 85/64 88/66 93/70 96/72 lbs 6,000 8,000 10,000 12,000 14,000 16,000 20,000 24,000 28,000 32,000 Flange x Traverse in 138x95 126x95 126x95 126x95 150x95 150x95 158x95 150x95 150x95 158x95 Shipping Reel Capacity 2 ft 3,000 2,950 2,950 2,950 3,000 3,000 2,725 2,450 2,150 1,900 Electrical Electrical Stress @ U o Shield kv/mm 7.2 7.2 7.2 7.2 7.2 7.2 6.9 6.8 6.6 6.4 Insulation Shield kv/mm 2.8 3.2 3.4 3.6 3.8 4.0 4.0 4.1 4.0 4.0 Short Circuit for 0.5s 3 ka 76.9 102.5 128.1 153.8 179.4 205.0 256.3 307.5 358.8 410.0 Sheath ka 41.6 42.1 43.1 44.0 44.9 45.7 49.7 51.9 54.6 56.7 Resistance DC @ 20 o C Ω/kft 0.014 0.011 0.008 0.007 0.007 0.005 0.004 0.004 0.003 0.003 DC @ 90 o C Ω/kft 0.018 0.014 0.011 0.009 0.008 0.007 0.005 0.005 0.004 0.003 Capacitance pf/ft 41.7 47.3 52.2 57.0 61.3 65.6 72.3 76.8 79.4 82.2 Charging Current Amps/ kft 1.46 1.66 1.83 2.00 2.15 2.30 2.53 2.69 2.78 2.88 Ampacity @ 90o C per circuit Typical Single Ductbank 4 Amps 714 842 952 1037 1111 1179 1413 1532 1633 1718 Power Rating MVA 200 235 266 290 310 329 395 428 456 480 Typical Double Ductbank 4 Amps 607 711 799 866 924 977 1163 1255 1330 1393 Power Rating MVA 170 199 223 242 258 273 325 350 371 389 Section 5 161 kv Power Cables SW Standard Wall XLPE Copper Corrugated Sheath 1 2500-4000 kcmil conductors are 5 segment Milliken conductors. 2 Increased shipping reel capacity can be accommodated on request. 64 3 Declared values for 30 mils copper sheath. Thicker sheath can accommodate more current. 4 4ft top of duct, 1 o C-m/W native, 0.8 o C-m/W ductbank backfill, 25 o C Ambient, 75% lf, 9 spacing, single-point or cross bonded

161 kv Power Cables 161 kv XLPE - Aluminum SW Standard Wall XLPE Aluminum Corrugated Sheath Cable Construction Reverse Concentric Stranded Aluminum, Compressed Super Smooth Shield Super Clean XLPE Insulation 690 mil XLPE minimum True Triple Extrusion and Dry Cured Firmly Bonded Insulation Shield Welded Aluminum Corrugated Sheath Polyethylene Jacket with Extruded Semi-Conductive Outer Layer Cable Data Voltage Characteristics (kv) Max Voltage Rating 169 BIL Rating 750 Temperatures ( o C) Nominal 90 Max. Emergency 105 Short Circuit 250 Minimum Installation -10 Design Characteristics Design Standards AEIC, IEC Typical Test Voltages 280 kv / 15 min. XLPE Loss Factor 0.0005 Relative Permittivity 2.3 65

Size in kcmil 750 1000 1250 1500 1750 2000 Dimensional Nominal Diameter in 0.97 1.12 1.26 1.38 1.49 1.61 mm 24.7 28.5 31.9 35.0 37.8 40.9 Insulation Thickness mils 840 790 760 730 710 690 mm 21.3 20.1 19.3 18.5 18.0 17.5 Diameter over Insulation in 2.77 2.82 2.89 2.95 3.02 3.08 mm 70.3 71.6 73.4 74.9 76.7 78.3 Diameter over Sheath in 3.42 3.47 3.55 3.62 3.70 3.76 mm 86.9 88.1 90.2 91.9 93.9 95.6 Overall Jacket Diameter in 3.70 3.76 3.83 3.90 3.98 4.04 mm 94.1 95.5 97.3 99.0 101.0 102.7 Total Weight lbs/ft 4.5 4.7 5.0 5.3 5.6 5.9 Min. Bending Radius (install/perm.) in in 74/56 75/56 77/57 78/58 80/60 81/61 Maximum Pulling Tension lbs 4,500 6,000 7,500 9,000 10,500 12,000 Typical Shipping Reel Size Flange x Traverse in 150x95 150x95 150x95 150x95 150x95 150x95 Shipping Reel Capacity 1 ft 3,000 3,000 3,000 3,000 3,000 2,725 Electrical Electrical Stress @ U o Shield kv/mm 7.2 7.2 7.2 7.2 7.2 7.2 Insulation Shield kv/mm 2.8 3.2 3.4 3.6 3.8 4.0 Short Circuit for 0.5s 2 ka 50.8 67.7 84.6 101.5 118.5 135.4 Sheath ka 46.8 47.4 48.5 49.5 50.5 51.4 Resistance DC @ 20 o C Ω/kft 0.023 0.017 0.014 0.012 0.010 0.009 DC @ 90 o C Ω/kft 0.030 0.022 0.018 0.015 0.013 0.011 Capacitance pf/ft 41.7 47.3 52.2 57.0 61.3 65.6 Charging Current Amps/ kft 1.46 1.66 1.83 2.00 2.15 2.30 Ampacity @ 90 o C per circuit Typical Single Ductbank 3 Amps 559 665 758 833 902 969 Power Rating MVA 156 186 212 233 252 271 Typical Double Ductbank 3 Amps 475 562 637 697 751 804 Power Rating MVA 133 157 178 195 210 225 1 Increased shipping reel capacity can be accommodated on request. 2 Declared values for 50 mils alluminum sheath. Thicker sheath can accommodate more current. 3 4ft top of duct, 1 o C-m/W native, 0.8 o C-m/W ductbank backfill, 25 o C Ambient, 75% lf, 9 spacing, single-point or cross bonded Section 5 161 kv Power Cables SW Standard Wall XLPE Aluminum Corrugated Sheath 66

161 kv Power Cables 161 kv XLPE - Copper SW Standard Wall XLPE Copper Neutrals with Copper Composite Lam inate Sheath Cable Construction Reverse Concentric Stranded Copper, Compressed or Milliken Super Smooth Shield Super Clean XLPE Insulation 690 mil XLPE minimum True Triple Extrusion and Dry Cured Firmly Bonded Insulation Shield Copper Neutrals with Copper Composite Laminate Sheath Polyethylene Jacket with Extruded Semi-Conductive Outer Layer Cable Data Voltage Characteristics (kv) Max Voltage Rating 169 BIL Rating 750 Temperatures ( o C) Nominal 90 Max. Emergency 105 Short Circuit 250 Minimum Installation -10 Design Characteristics Design Standards AEIC, IEC Typical Test Voltages 280 kv / 15 min. XLPE Loss Factor 0.0005 Relative Permittivity 2.3 67

Size in kcmil 1 750 1000 1250 1500 1750 2000 2500 3000 3500 4000 Dimensional Diameter Insulation Thickness Diameter over Insulation Diameter over Sheath Overall Jacket Diameter Nominal in 0.97 1.12 1.25 1.37 1.48 1.61 1.76 1.92 2.08 2.21 mm 24.7 28.5 31.8 34.8 37.6 40.9 44.7 48.8 52.8 56.1 mils 840 790 760 730 710 690 700 710 720 730 mm 21.3 20.1 19.3 18.5 18.0 17.5 17.8 18.0 18.3 18.5 in 2.77 2.82 2.89 2.95 3.02 3.08 3.36 3.52 3.72 3.87 mm 70.3 71.6 73.4 74.9 76.7 78.3 85.3 89.4 94.4 98.3 in 3.15 3.20 3.28 3.34 3.41 3.47 3.69 3.87 4.05 4.20 mm 80.1 81.3 83.2 84.7 86.5 88.1 93.8 98.3 102.8 106.7 in 3.47 3.52 3.60 3.66 3.73 3.79 4.01 4.19 4.37 4.52 mm 88.2 89.5 91.3 92.8 94.6 96.2 101.9 106.5 110.9 114.8 Total Weight lbs/ft 6.7 7.5 8.4 9.2 10.0 10.8 12.8 14.6 16.5 18.4 Min. Bending Radius (install/ perm.) Maximum Pulling Tension Typical Shipping Reel Size in 69/52 70/53 72/54 73/55 75/56 76/57 80/60 84/63 87/65 90/68 lbs 6,000 8,000 10,000 12,000 14,000 16,000 20,000 24,000 28,000 32,000 Flange x Traverse in 138x95 138x95 138x95 138x95 150x95 150x95 150x95 150x95 158x95 158x95 Shipping Reel Capacity 2 ft 3,000 3,000 3,000 3,000 3,000 3,000 2,725 2,600 2,250 2,025 Electrical Electrical Stress @ U o Shield kv/mm 7.2 7.2 7.2 7.2 7.2 7.2 6.9 6.8 6.6 6.4 Insulation Shield kv/mm 2.8 3.2 3.4 3.6 3.8 4.0 4.0 4.1 4.0 4.0 Short Circuit for 0.5s 3 ka 76.9 102.5 128.1 153.8 179.4 205.0 256.3 307.5 358.8 410.0 Sheath ka 43.8 43.9 44.1 44.3 44.5 44.6 45.2 45.7 46.1 46.5 Resistance DC @ 20 o C Ω/kft 0.014 0.011 0.008 0.007 0.007 0.005 0.004 0.004 0.003 0.003 DC @ 90 o C Ω/kft 0.018 0.014 0.011 0.009 0.008 0.007 0.005 0.005 0.004 0.003 Capacitance pf/ft 41.7 47.3 52.2 57.0 61.3 65.6 72.3 76.8 79.4 82.2 Charging Current Amps/ kft 1.46 1.66 1.83 2.00 2.15 2.30 2.53 2.69 2.78 2.88 Ampacity @ 90 o C per circuit Typical Single Ductbank 4 Amps 724 856 969 1058 1136 1209 1464 1602 1723 1830 Power Rating MVA 202 239 271 296 317 338 409 447 481 511 Typical Double Ductbank 4 Amps 614 721 813 883 944 1001 1209 1317 1412 1495 Power Rating MVA 172 202 227 247 264 280 338 368 394 417 Section 5 161 kv Power Cables sw standard wall xlpe Copper Neutrals with Copper Composite Laminate Sheath 1 2500-4000 kcmil conductors are 5 segment Milliken conductors. 2 Increased shipping reel capacity can be accommodated on request. 68 3 Declared values for 80 x 14 AWG copper wire screen with 6 mil copper tape shield. Larger wires can accommodate more current. 4 4ft top of duct, 1 o C-m/W native, 0.8 o C-m/W ductbank backfill, 25 o C Ambient, 75% lf, 9 spacing, single-point or cross bonded

161 kv Power Cables 161 kv XLPE - Aluminum SW Standard Wall XLPE Copper Neutrals with Aluminum Composite Laminate Sheath Cable Construction Reverse Concentric Stranded Aluminum, Compressed Super Smooth Shield Super Clean XLPE Insulation 690 mil XLPE minimum True Triple Extrusion and Dry Cured Firmly Bonded Insulation Shield Copper Neutrals with Aluminum Composite Laminate Sheath Polyethylene Jacket with Extruded Semi-Conductive Outer Layer Cable Data Voltage Characteristics (kv) Max Voltage Rating 169 BIL Rating 750 Temperatures ( o C) Nominal 90 Max. Emergency 105 Short Circuit 250 Minimum Installation -10 Design Characteristics Design Standards AEIC, IEC Typical Test Voltages 280 kv / 15 min. XLPE Loss Factor 0.0005 Relative Permittivity 2.3 69

Size in kcmil 750 1000 1250 1500 1750 2000 Dimensional Nominal Diameter in 0.97 1.12 1.26 1.38 1.49 1.61 mm 24.7 28.5 31.9 35.0 37.8 40.9 Insulation Thickness mils 840 790 760 730 710 690 mm 21.3 20.1 19.3 18.5 18.0 17.5 Diameter over Insulation in 2.77 2.82 2.89 2.95 3.02 3.08 mm 70.3 71.6 73.4 74.9 76.7 78.3 Diameter over Sheath in 3.16 3.21 3.28 3.34 3.41 3.47 mm 80.2 81.4 83.3 84.8 86.6 88.2 Overall Jacket Diameter in 3.48 3.53 3.60 3.66 3.73 3.79 mm 88.3 89.6 91.4 92.9 94.7 96.3 Total Weight lbs/ft 5.0 5.2 5.5 5.8 6.1 6.4 Min. Bending Radius (install/perm.) in 70/52 71/53 72/54 73/55 75/56 76/57 Maximum Pulling Tension lbs 4,500 6,000 7,500 9,000 10,500 12,000 Typical Shipping Reel Size Flange x Traverse in 138x95 138x95 138x95 138x95 150x95 150x95 Shipping Reel Capacity 1 ft 3,000 3,000 3,000 3,000 3,000 3,000 Electrical Electrical Stress @ U o Shield kv/mm 7.2 7.2 7.2 7.2 7.2 7.2 Insulation Shield kv/mm 2.8 3.2 3.4 3.6 3.8 4.0 Short Circuit for 0.5s 2 ka 50.8 67.7 84.6 101.5 118.5 135.4 Sheath ka 42.8 42.9 43.1 43.3 43.4 43.6 Resistance DC @ 20 o C Ω/kft 0.023 0.017 0.014 0.012 0.010 0.009 DC @ 90 o C Ω/kft 0.030 0.022 0.018 0.015 0.013 0.011 Capacitance pf/ft 41.7 47.3 52.2 57.0 61.3 65.6 Charging Current Amps/ kft 1.46 1.66 1.83 2.00 2.15 2.30 Ampacity @ 90 o C per circuit Typical Single Ductbank 3 Amps 566 675 771 848 920 990 Power Rating MVA 158 189 216 237 257 277 Typical Double Ductbank 3 Amps 480 569 646 708 765 821 Power Rating MVA 134 159 181 198 214 229 1 Increased shipping reel capacity can be accommodated on request. 2 Declared values for 80 x 14 AWG copper wire screen with 8 mil aluminum tape shield. Larger wires can accommodate more current. 3 4ft top of duct, 1 o C-m/W native, 0.8 o C-m/W ductbank backfill, 25 o C Ambient, 75% lf, 9 spacing, single-point or cross bonded Section 5 161 kv Power Cables SW Standard Wall XLPE Copper Neutral, Aluminum Composite Laminate Sheath 70