Grounding of Electrical Systems NEW CODE: Grounding and Bonding



Similar documents
Grounding & Bonding Why it is done And How to Install Properly

Services. Three Phase Service

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

TABLE OF CONTENT

Electrical Grounding. Appendix C

Video Camera Installation Guide

TC Grounding and Bonding for Telecommunications Systems

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

STREETLIGHT SYSTEM GROUNDING AND BONDING

ELECTRICAL SAFETY Information Bulletin

The following table shows approximate percentage wise the

Chapter 9. Bonding and Grounding

PORTABLE GENERATORS AND OSHA CONSTRUCTION REGULATIONS

1. Franklin Rod Performance 2. LEC/DAS Performance

GROUNDING AND BONDING ELECTRICAL SYSTEMS

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

Grounding Practice at Data and Communications Centers. David Brender, P.E., CPQ National Program Manager Copper Development Association Inc.

David Brender Copper Development Association Inc. Miramar, March 8, 2013

White Paper: Electrical Ground Rules

Customer Substation Manual 08/05/02

800 Communications Circuits

SAES-P January, 2004 Grounding. Electrical Systems Designs & Automation Standards Committee Members

Corner-Grounded Delta (Grounded B Phase) Systems

PROTECTION AGAINST ELECTRIC SHOCK by John Ware

Hyperlinks are Inactive

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port

IRRIGATION PUMPING Table of Contents - Section 900

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd

4.5 Transformer Connections

Earth Ground Resistance

Fortune Oregon Data Center Increases Reliability with a High Resistance Grounding System

Rule Fast Track Analysis for National Life Insurance Co.

Substation Grounding Study Specification

Lightning Arresters P KVA P KVA. Description & Installation

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

SECTION 22 LIGHTNING PROTECTION SYSTEM

Tips for connecting 24-volt power

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Product Guide. Low voltage grounding system. Answers for industry.

ELECTRICAL INSPECTION BULLETIN (Effective )

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

SPECIAL TOPICS ON GROUND FAULT PROTECTION AND PROTECTION COORDINATION IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS

System Grounding and Ground-Fault Protection Methods for UPS-Supplied Power Systems

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

CUSTOMER REQUIREMENTS AT POWER SUBSTATIONS

Grounding of AC generators and switching the neutral in emergency and standby power systems

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide.

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

Lightning Protection Introduction

Power Quality for Information Technology System

Atlanta Chapter IEEE Industry Applications Society

Section B: Electricity

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

Application Guidelines for Transformer Connection and Grounding for Distributed Generation: An Update

Three-Phase Electric Power Distribution for Computer Data Centers

PXL-250: Network Wiring

Chapter 2. Grounding & Shielding. 2.1 Grounding generalities

Preface. Integrating Electronic Equipment and Power into Rack Enclosures Middle Atlantic Products, Inc.

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

How Much Voltage Drop Is Acceptable?

Earthing Guidance Notes

GroundRod AC Substation Earthing Tutorial

Model 1756 Test Lead Kit

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

Earth Fault Detection Basics in Theory

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Arc Fault Circuit Interrupters Frequently Asked Questions

Assessment of Soil Resistivity on Grounding of Electrical Systems: A Case Study of North-East Zone, Nigeria

Electrical safety requirements in DC distribution systems

How to design SMPS to Pass Common Mode Lightning Surge Test

The Service Entrance. Technical Terms Drip loop Insulator Meter Meter enclosure

Applications. Remote Display Mounting Kits

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

Fundamentals of Power

Switchgear Application Issues for Mission Critical Power Systems, Part One

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

CSA Z32 TESTING GUIDELINE AND PROCEDURES

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

Grounding and Electrical Safety of Shore Power Supply and DC Stinger System Design

Construction work requires electrical

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants

AC and DC Drive System Installation Information

Douglas J. Reinemann, Ph.D. University of Wisconsin-Madison, Department of Agricultural Engineering Madison, Wisconsin. and

Short Circuit Current Calculations

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

Transcription:

Grounding of Electrical Systems NEW CODE: Grounding and Bonding Presented By Scott Peele PE

Grounding of Electrical Systems Outline Defining the Terms Why should I Ground? Types of Grounding Systems Separately Derive System Grounding Electrode Bonding Ground Fault Protection Ground Reference or Signal Reference Grounding for Lightning Protection

Definitions Review definition as we encounter them. Grounded vs Grounding Isolated Ground Floating Ground Ground Loop Net Current

Why am I grounding or Not? Safety Grounding for Fault Current Paths Grounding for Touch Potential (static) Grounding for Lightning Protection Surge Arresters, TVSS (SPD) Grounding for Signal Reference (RF, Data, static,etc.) Not Grounding Continuous operation

Three reasons for grounding Fault Protection Lightning Protection Signal Reference

Grounded vs Grounding Grounded vs. grounding in an electrical system. Grounded system refers to a system where a conductor is grounded and is intended to or may carry current in the normal operation. The neutral on a wye system is a prime example of a grounded conductor. The grounding conductor system is not intended to carry operational current in its design. This path is intended to carry unwanted and fault currents for protection.

Types of AC Grounded Systems Ungrounded system Solidly Grounded System Resistance Grounded Reactance Grounded Ground Fault Neutralizer

Which System to Use?? Safety - Who is Operating the System Ground Fault Detection Signal Reference Touch Potential (also static) Available Fault Currents? Operation Stability System Response

Ungrounded System Type of system typically used on is a Delta service. Some time used on a floating Wye Detection System in Place Ground Detection by Lighting Zigzag Grounding Transformer Ground Relay Ground Fault???

Detection Devices

Solidly Grounded System Usually use in Wye systems Return Fault current to trip overcurrent protection device quickly Usually better reference and safer system Much better for lightning protection Can be used in Corner Grounded Delta Problems with phase grounded re-grounded Not good on lightning protection equipment

Resistive grounded Low Resistance Limit Fault Current Minimizes the damage at the fault Used usually with multiple sources i.e. transformers, and or generators High Resistance Enables system operation with one phase grounded Enables current to flow for detection networks Current is low enough so that no damage occurs

Reactance Grounding Reactor connected between system neutral and ground Reduces the ground fault current between phase and ground Usually higher fault current than low resistance grounding Better coordination with fault currents on multi-grounded system. Mostly used on system above 5kV.

Ground-Fault Neutalizer Reactor with relatively high value of reactance. Usually on system above 15kV phase to ground air exposed. (overhead Transmission and Distribution) May provide insulator flashover with selfextinguishing characteristics.

Separately Derived System The system grounding conductor for a separately derived system shall be grounded at only one point. Main system Disconnecting means for a main utility feed, or a step down or step up transformer, or a generator could all be separately derived systems. When grounded it will be grounded at the nearest grounding electrode.

Grounding Electrode System and Grounding Electrode Conductor Part III NEC 250.50 (Grounding Electrode System) 250.52 Electrodes Water Pipe if 10 ft. or more of metal water pipe is in contact with the earth. Metal Frame of the Building or Structure where the following methods are used to make an earth connection: (1,2,3,4) Concrete-Encased Electrode in at least 2 of concrete located within and near the bottom of a concrete foundation or footing that is in indirect contact with the earth. Ground Ring encircling the building or structure in direct contact with the earth Rod or Pipe electrode not less than 8 ft in length Plate Electrode not less than 2 square ft. Other Local underground systems such as piping, underground tanks and underground metal well casing NOT Permitted Metal underground gas piping Aluminum electrode

Grounding Electrode System Installation NEC 250.53 This requirement clarifies that the supplemental electrode system must be installed as if it were the sole grounding electrode Bonding NEC 250.53 C This requirement is for bonding of multiple electrodes.

Bonding Bonding for Main Bonding Jumper System Bonding Jumper Electrode Bonding Part V Bonding Where necessary to ensure electrical continuity and the capacity to conduct safely and fault current likely imposed.

Ground? Hot Neutral Ground

Review Ohms Law Voltage = Current X Resistance (Potential) (amps) (ohms) BONDING Ground Rod Develop VOLTAGE Develop VOLTAGE Ground Rod Current Source Lightning Average current 30,000 amps

Grounding and Bonding Voltage Difference Transient voltages and currents at data port or cable connections

Isolated Ground NEC 250.146 (D) Isolated ground receptacle (orange triangle) NEC 406.2(D) NEC 250.96 (B) Isolated Grounding Circuits NEC 647 Section Sensitive Electronic Equipment. NEC 647.6 Grounding. Technical Equipment Ground

Isolated Ground Isolated grounded receptacle has an isolated terminal from the yoke to the ground Lug. These receptacle are usually marked with an orange triangle or all orange. Sub Panel Neutral Bus Ground Bus

Floating Ground The neutral on a wye system is not intentionally grounded Signal conductor shielding is not intentionally grounded Problem is high transient voltage or overvoltages may exist causing damage. Not a good way for lightning protection

Ground Loop Grounds from two different derived system are connected Open ground loops. Grounds are not bonded properly and cause damage. Ground loops cause circulating current between systems and cause transformer coupling (CT s) Signal reference can be compromised causing data errors.

Grounding for Signal Reference Don t Burst the Bubble. Ground on one end Ground on both ends Ground on neither end Fiber Optic Best Answer Optical Coupler

Don t Burst the Bubble

Ground Fault Interrupter Function

Net Current Currents that are not apart of the normal operation of a derive electrical system. All positive, negative, and zero sequence currents added and the resultant current are net currents.

Books On Grounding NEC IEEE Green Book 142-1991 Recommended Practice for Grounding of Industrial and Commercial Power Systems Emerald Book 1100-1999 Recommended Practice for Powering and Grounding Sensitive Electronic Equipment Industrial and Commercial Power system Handbook