Applications. Remote Display Mounting Kits

Size: px
Start display at page:

Download "Applications. Remote Display Mounting Kits"

Transcription

1 June 200 Sheet 105 Surge Protection Products TVSS General Description Clipper Power System Visor Series.1-5 Clipper Power System Visor Series General Description Eaton s Cutler-Hammer leading-edge surge suppression system for retrofit applications offers the widest variety of surge current rating, monitoring features, and enclosure options. The Visor Series is the most up-to-date and respected line of surge protection devices in the industry due to its exceptional technology and performance. With over two decades of experience in the surge suppression industry and extensive R & D initiatives, Eaton is considered a world leader in surge protective device (SPD) manufacturing. When installing a surge suppressor in a retrofit environment, it is important to mount the suppressor as close to the electrical equipment as possible. Keep the wiring (lead length) between the electrical equipment and the suppressor as short as possible, and twist or wire tie the conductors to reduce inductive effects. Installation lead length reduces the performance of any surge suppressor. For each inch of wiring (installation lead length), add 15 to volts to the surge suppressor s published let-through value (e.g., suppressor let-through at 0 V and installation of 3 feet (.9 m) of cable = 1000 V installed rating). Visor Series Retrofit and Integrated Versions Applications The Visor can be integrated switchboards, switchgear, motor control centers, panelboards and busway. The Visor can also be externally mounted to existing distribution equipment. Standard NEMA 1/3R retrofit enclosure. NEMA 4X and NEMA 12 enclosure available as an option. Enclosures with disconnect switch available as an option. The Visor is available from 100 to 500 ka/phase units. Remote Display Mounting Kits The monitoring display panel can be remotely mounted on the Visor using either ribbon cables or DB15 connector cable. Both optional kits can be ordered separately. Cable supplied in the kits comes in different lengths. Refer to Table.1-1. Table.1-1. Remote Mounting Kits/Cables Description Catalog Number Ribbon Cable 3 ft. (1.0 m) ft. (1.8 m) DB15 00 V Cable 8 ft. (2.5 m) 1 ft. (5.0 m) NetVisor Cables 8 ft. (2.5 m) 1 ft. (5.0 m) Kits Advisor Display SuperVisor Display NetVisor Display CPSRIB03 CPSRIB0 CPSDB08 CPSDB1 CPSNVDB08 CPSNVDB1 CPSRDPKITA CPSRDPKITV Consult Factory Features, Functions and Benefits Standard Features 200 kaic internal fusing system. Thermo-Dynamic Fusing System. Standard NEMA 1/3R enclosure. AdVisor monitoring package, which is loaded with features. An audible alarm with reset button, Form C dry contacts and phase operating status lights. Remote mountable display panel. Features SuperVisor and NetVisor monitoring packages. Different enclosure packages. OEM packages. Industry Leadership The Visor is an intelligent surge suppression device that offers advanced monitoring options. It offers improved safety and reliability from a new patent pending technology Thermo- Dynamic Fusing. Independently tested by lightning laboratories to ensure performance, long-term reliability, and quality standards are met. Installation flexibility for all low voltage distribution equipment. Worldwide customer, engineering and application support. Application Flexibility 100, 120, 10, 200, 0, 0, 0 and 500 ka/phase ratings are available. units utilize our low impedance SurgePlane suppression platform to ensure surge currents are equally diverted to all suppression components, therefore extending life expectancy. Neutral Copper Surge Planes Figure.1-5. SurgePlane Technology Surge Current Equally Diverted

2 .1- Surge Protection Products TVSS General Description Clipper Power System Visor Series June 200 Sheet 10 Comprehensive Diagnostics Maintenance-free surge suppression. (No external test set or routine maintenance required.) The NetVisor, our premium display, allows you to monitor your surge protective device from across the plant or across the world. AdVisor and SuperVisor monitoring display panels are completely removable and can be installed horizontally or vertically, offering four mounting positions. AdVisor and SuperVisor displays can be remotely mounted using the RDP kits and cables. See Table.1-1. Visor Monitoring Options Our patent-pending Thermo- Dynamic Fusing System provides both safety and performance. This technology uses a fuse trace on each individual metal oxide varistor (MOV) that can sustain high surge currents and provide the necessary interruption of high fault currents (kaic). Thermo-Dynamic Fusing System also includes a thermal fuse spring (TFS) that provides the needed disconnection from low level fault currents. Components of the Thermo-Dynamic Fusing System Standards and Certifications Clipper units have been tested by UL and meet the requirements under UL nd Edition for surge suppression devices. Clipper units have been tested as per NEMA LS-1 and ANSI/IEEE C2.45. Category A3 Ringwave ( kv open circuit, 200 A short circuit current at 100 khz). Category B3 Ringwave ( kv open circuit, 500 A short circuit current at 100 khz). Category C1 Combination Wave ( kv 1.2/50us open circuits, 3 ka 8/20us short circuit current). Category C3 Combination Wave (20 kv 1.2/50us open circuits, 10 ka 8/20us short circuit current). UL 1020 (standard for safety for thermal cutoffs for use in electrical appliances and components). UL 13 listed for EMI/RFI noise attenuation filtering (50 db at 100 khz), CSA C.2. Ribbon Cables in 3- or -Foot (1.0 or 1.8 m) Lengths Remote Display Panel DB Cables in 8- or 1-Foot (2.5 or 5.0 m) Lengths

3 June 200 Sheet 10 Surge Protection Products TVSS General Description Clipper Power System Visor Series.1- Visor Display Packages Table.1-2. Visor Series Description AdVisor SuperVisor NetVisor Diagnostics Package Status Indicator Lights Red/Green Form C Contacts Audible Alarm with Reset Button Transient Counter Push-to-Test Button Power Consumption in Watts 0.5 W 1.2 W 3.0 W Remote Mounting Kits Ribbon Cable DB15 Cable PQ Meter Adjustable Set Points Non-Volatile Memory Web Enabled Date Stamped Communication Port Modbus and Ethernet Communication Speed (10Base-T) Temperature Storage Operating Humidity (Relative) = 5% 95% Remote Mountable Display Dimensions (4.20-inch W x 4.20-inch H x 0.-inch D) (10. x 10. x 10.2 mm) Power Quality (PQ) Metering % Life Remaining % THD (Voltage) Event Storage (9999 Events) LCD (2 x 1) Event Capture Sag Counter -ºC to +0ºC -ºC to +0ºC -ºC to +0ºC -20ºC to +0ºC Counter: -10% System Voltage Cycles Fixed Set Points Swell Counter Counter: +10% System Voltage One Cycle Fixed Set Points Outage Counter Counter: Zero Voltage 2 Cycles Fixed Set Points Surge Counter Counter: Sensitivity Minimum x 20 vs. Waveform Voltage Meter L L N G -ºC to +0ºC -20ºC to +0ºC Meter: User-Defined Set Points for Voltage Trigger 1 Cycle Meter: User-Defined Set Points for Voltage Trigger 1 Cycle Meter: >10% System Voltage 1 Cycle Fixed Set Point Meter: Sensitivity Minimum x 20 vs. Waveform Accuracy ± 5% ± 5% Resolution 8 bit 8 bit Note: = = No = Not Applicable

4 .1-8 Surge Protection Products TVSS General Description Clipper Power System Visor Series June 200 Sheet 108 Table.1-3. Service Entrance Applications Switchboard Switchgear Motor Control Centers The Visor can be integrated into any switchboard. Specifiers have the flexibility to install the Visor in any location within the switchboard. Disconnect switch is a standard feature. Unique design minimizes installation impedance. UL 891 (Switchboard) UL 13 (EMI/RFI Filter) CSA C.2 Certified (Suppressor) Available on all switchgear designs. Disconnect switch is a standard feature. Unique design minimizes installation impedance. CPS0 ideal for critical industrial switchgear applications. UL 1558 (Switchgear) UL 13 (EMI/RFI Filter) CSA C.2 Certified (Suppressor) Panelboards Busway Retrofit Ideal protection for PLCs, sensors, drives, electronic starters, or other digital equipment. Visor is designed to fit in Freedom 2100 and Advantage MCCs in a standard (3X) size 18-inch (45.2 mm) compartment. May be used in new/aftermarket applications. Ideal for water treatment, petrochemical and other industrial applications. UL 845 (MCC) UL 13 (EMI/RFI Filter) CSA C.2 Certified (Suppressor) The Visor is used extensively on branch panelboards for computer rooms, laboratories, schools, hospitals and industrial applications. 200% rated neutral is provided for non-linear loads. Cost-effective branch protection (assumes main panel protection employed). UL (Panelboards) UL 13 (EMI/RFI Filter) CSA C.2 Certified (Suppressor) Ideal for busway fed distribution systems. Easy to install Visor units, fit in standard bus plug assembly. Full diagnostic and monitoring capabilities. Isolates critical busway sections from nearby disturbance producing loads. Designed for new and existing facilities. Integral disconnect. UL 85 (Busway) UL 13 (EMI/RFI Filter) CSA C.2 Certified (Suppressor) TVSS Filters can be externally mounted to existing distribution equipment. Standard NEMA 1/3R enclosures. Requires field installation. Visor Retrofit 100 to 500 ka/phase units. Clipper VL 50, 80 and 100 ka/phase units. UL 13 (EMI/RFI Filter) CSA C.2 Certified (Suppressor) Note: The CPS Surge components can be integrated into safety switches, automatic transfer switches (ATS) and other assemblies. Contact your local Eaton sales office.

5 June 200 Sheet 109 Visor Series Ordering Guidelines Table.1-4. Retrofit Surge Protection Products TVSS General Description Clipper Power System Visor Series CPS Y S K.1-9 Surge Ratings 100 = 100 ka/phase 120 = 120 ka/phase 10 = 10 ka/phase 200 = 200 ka/phase 0 = 0 ka/phase 0 = 0 ka/phase 0 = 0 ka/phase 500 = 500 ka/phase Diagnostics Packages A = AdVisor c/w Status indicator lights on each phase, Form C, Audible Alarm Enable/Disable S = SuperVisor c/w Status indicator lights on each phase, Form C, Audible Alarm Enable/Disable, Transient Counter, Push-to-Test, PQ Meter (no date stamp) N = NetVisor c/w Status indicator lights on each phase, Form C, Audible Alarm Enable/Disable, Transient Counter, Push-to-Test, PQ Meter (date stamp), Modbus and Ethernet Communication Port, % Life Remaining, % Voltage THD Enclosure Cross-Reference K = Standard (NEMA 1, 3R) L = Flushmount (NEMA 1) M = Standard (NEMA 1, 3R) c/w Disconnect Switch N = NEMA 4X O = NEMA 4X c/w Disconnect Switch P = NEMA 12 Q = NEMA 12 c/w Disconnect Switch Voltage Code 120/208 1/0 0 V 0/1 Three-Phase Wye (4W+G) (Mexico) 120/0 Single Split Phase (3W+G) Three-Phase Delta High Leg (4W+G) Three-Phase Wye (4W+G) Three-Phase Delta (3W+G) 0Y 0S 0H 208Y 0D 2/0 0 V 0Y / V 480Y 480D /00 00 V 00Y 00D Disconnect switch 3-pole ampere Type FDC breaker. Table.1-5. Integrated CPS Y S C Surge Ratings 100 = 100 ka/phase 120 = 120 ka/phase 10 = 10 ka/phase 200 = 200 ka/phase 0 = 0 ka/phase 0 = 0 ka/phase 0 = 0 ka/phase 500 = 500 ka/phase Diagnostics Packages A = AdVisor c/w Status indicator lights on each phase, Form C, Audible Alarm Enable/Disable S = SuperVisor c/w Status indicator lights on each phase, Form C, Audible Alarm Enable/Disable, Transient Counter, Push-to-Test, PQ Meter (no date stamp) N = NetVisor c/w Status indicator lights on each phase, Form C, Audible Alarm Enable/Disable, Transient Counter, Push-to-Test, PQ Meter (date stamp), Modbus and Ethernet Communication Port, % Life Remaining, % Voltage THD Enclosure Cross-Reference A = Panelboards (PRL1A, 2A, 3A, 4) B = Remote Monitor Display (PRL4, Switchgear, Busway) C = MCC Version D J = Warranty Versions, Consult Factory Y = OEM Mounting Plate Version (Fixed Display) Z = OEM Mounting Plate Version (c/w Remote Display Panel Option) Valid for 0/5 and 0/5 per IEC standards. Voltage Code 120/208 1/0 0 V 0/1 Three-Phase Wye (4W+G) (Mexico) 120/0 Single Split-Phase (3W+G) Three-Phase Delta High Leg (4W+G) Three-Phase Wye (4W+G) Three-Phase Delta (3W+G) 0Y 0S 0H 208Y 0D 2/0 /480 0 V 480 V 0Y 480Y 480D /00 00 V 00Y 00D

6 .1-10 Surge Protection Products TVSS Dimensions Clipper Power System Visor Series June 200 Sheet 110 Dimensions Standard Dimensions in Inches (mm) Retrofit Only (1.0) (508.0) 1.00 (.4).00 (558.8) (45.2) 3.90 (99.1) Figure.1-. NEMA 1 Flushmount up to 200 ka (480 V or Less) 1.00 (1.8) Figure.1-8. NEMA 1 Flushmount 0 ka and up (480 V or Less/00 V, 100 ka 500 ka) 3.90 (99.1) 1.00 (.4) (45.2) (9.4) 3.90 (99.1) (3.2) 3.90 (99.1) Figure.1-. NEMA 1/3R up to 200 ka (480 V or Less) Figure.1-9. NEMA 1/3R 0 ka and up (480 V or Less/00 V, 100 ka 500 ka)

7 June 200 Sheet 111 Surge Protection Products TVSS Dimensions Clipper Power System Visor Series.1-11 Standard Dimensions in Inches (mm) Retrofit Only (Continued) 8.0 (218.4) (45.2) (55.3) 1.00 (.4) Figure NEMA 4X up to 500 ka ( Voltages) (45.2) Figure NEMA 4X c/w Disconnect Switch (Up to 500 ka/ Voltages) 10. (4.2).0 (54.0) (8.1) Figure NEMA 1/3R c/w Disconnect Switch (Up to 500 ka/ Voltages) 5.20 (1.1)

8 .1-12 Surge Protection Products TVSS Technical Data Clipper Power System Visor Series June 200 Sheet 112 Technical Data Table.1-. Eaton s Cutler-Hammer Clipper Power System Visor Series Specifications Guide for applying the appropriate surge suppressor based upon life expectancy and performance. CPS Models CPS100 CPS120 CPS10 CPS200 CPS0 CPS0 CPS0 CPS500 Surge Current Per Phase 100 ka 120 ka 10 ka 200 ka 0 ka 0 ka 0 ka 500 ka Surge Current Mode L-N (Line-to-Neutral) L-G (Line-to-Ground) N-G (Neutral-to-Ground) L-L (Line-to-Line, Delta, and Ungrounded Applications Only) Single Pulse Surge Current Test Based on IEEE C2. 8 x 20 microsecond waveform Modes of Protection 3-Phase Wye System 3-Phase Delta System 50 ka 50 ka 50 ka 50 ka 0 ka 0 ka 0 ka 0 ka Direct Bus Bar Connection Warranty Clipper Power System Visor Series 10 Years 10 Years 10 Years 10 Years 10 Years 10 Years 10 Years 10 Years CPS0 recommend for service entrance. CPS120 recommended for branch locations using IEEE recommended cascade approach. sizes to meet competitive specifications. CPS have been independently tested to verify all suppressor components can survive published surge current ratings. Test documents are available upon request. 80 ka 80 ka 80 ka 80 ka 100 ka 100 ka 100 ka 100 ka 1 ka 1 ka 1 ka 1 ka 150 ka 150 ka 150 ka 150 ka 200 ka 200 ka 200 ka 200 ka 0 ka 0 ka 0 ka Filter Attenuation (Based on MIL-STD-0A) at 100 khz 50 db 50 db 50 db 50 db 50 db 50 db 50 db 50 db Surge Withstand Capabilities ANSI/IEEE C3 Wave (10 ka) 8,000 9,000 10,000 11,000 12,000 13,000 14,000 15,000 Thermo-Dynamic Fusing System Overcurrent Protection (Thermal Fuse Spring) 200 kaic Individual Fused MOVs Monitoring Display Options SuperVisor (Standard) AdVisor NetVisor 0 ka

CPS 100 480Y S K CPS 100 480Y S C

CPS 100 480Y S K CPS 100 480Y S C Ref. No. 1299 Visor Series Ordering Guidelines Table.1-4. Retrofit Surge Protection Products TVSS General Description Clipper Power System Visor Series CPS 100 480Y S K.1-9 Surge Ratings 100 = /phase 120

More information

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A SURGE PROTECTIVE DEVICES (SPDs) INTEGRATED UNITS LOW VOLTAGE AC SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS PART 1 GENERAL 01 02 03 SCOPE The Contractor shall furnish and install the Surge Protective

More information

Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1

Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1 Page 1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Divisions 1 Specification sections apply to

More information

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B SURGE PROTECTIVE DEVICES (SPDs) EXTERNAL SIDEMOUNT UNITS LOW VOLTAGE AC SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION PART 1 GENERAL 01 02 03 SCOPE The Contractor shall furnish and install the Surge Protective

More information

SURGELOGIC TVSS Surge Protective Devices Enhance System Protection and Reduce Equipment Damage

SURGELOGIC TVSS Surge Protective Devices Enhance System Protection and Reduce Equipment Damage TVSS Surge Protective Devices Enhance System Protection and Reduce Equipment Damage Internal and External Mounted TVSS Retrofit or New Construction Low Let-through Levels High Surge Capacities Internal

More information

Surgelogic Surge Protective Device (SPD)

Surgelogic Surge Protective Device (SPD) Surgelogic Surge Protective Device () EB, EM, and HW Series atalog 1310T0202R05/09 2009 lass 1310 OTETS Description............................................. Page Product Description...........................................2

More information

Surgelogic Surge Protection Device EMA, EBA, and HWA Series

Surgelogic Surge Protection Device EMA, EBA, and HWA Series Surgelogic Surge Protection Device EM, EB, and HW Series atalog 1310T0202R5/07 2007 lass 1310 OTETS Description..............................................Page Product Descriptions..........................................

More information

surge protection solutions

surge protection solutions Surge protection devices Innovative Technology Innovative and reliable surge protection solutions Eaton Innovative Technology SPD products Innovative Technology products are a part of Eaton s electrical

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design Basis of Design This section applies to the design, installation and integration of metering and monitoring equipment, including: hardware installed in the electrical service and distribution equipment,

More information

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

Protect your home and family with Advanced Technology from Cutler-Hammer

Protect your home and family with Advanced Technology from Cutler-Hammer Protect your home and family with Advanced Technology from Cutler-Hammer Residential Home Fire Statistics Annually - over 415,000 Residential Fires Annually - over 40,000 electrical fires over 350 deaths

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA - 12859 North America Version 5 August 22, 2008 Page 1

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA - 12859 North America Version 5 August 22, 2008 Page 1 Overview It's getting harder to manage a data center efficiently, with rising utility bills and ever-increasing demands due to processor power and server density increases. Growing user requests mean heavier

More information

Always On UPS Systems Inc., #100-150 Campion Road, Kelowna, BC Canada V1X 7S8

Always On UPS Systems Inc., #100-150 Campion Road, Kelowna, BC Canada V1X 7S8 Door Mount UPS (Patent Pending) Shelf Mount UPS (Patent Pending) DESCRIPTION: The Always On NDM (door mount) and NSM (shelf mount) Series UPS s are dual conversion online UPS systems provided in slim,

More information

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Learning Module 13: Panelboards and Switchboards. 101 Basic Series Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

Engineering Series Ratings: Is It Practical?

Engineering Series Ratings: Is It Practical? Engineering Series Ratings: Is It Practical? By the National Electrical Manufacturers Association The 2005 National Electrical Code (NEC) introduces a change regarding series ratings for circuit breakers

More information

Uninterruptible Power Supply

Uninterruptible Power Supply 96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features

More information

Power surges can also be generated by equipment in your facility such as:

Power surges can also be generated by equipment in your facility such as: Power Quality Surge Suppressors What is Surge Protection A surge suppressor can be the first and best defense against the instant or gradual destruction of electrical equipment. Compared to the replacement

More information

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch

More information

Continuous Power... Continuous Protection

Continuous Power... Continuous Protection Series 165 We Keep Your Power On Continuous Power... Continuous Protection An Automatic Transfer Switch helps prevent... Your business or home from losing power during bad weather or utility power equipment

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer 101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION Cutler-Hammer WELCOME Welcome to Module 3, Fundamentals of Electrical Distribution. If you have successfully completed Module

More information

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power App Notes ~ Outdoor Power System Design and Cost Considerations 1 Authors Peter Nystrom President TSi Power Corp. Coordination of Telecommunications Surge Protective Devices in Countries with Unstable

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

Short Circuit Current Calculations

Short Circuit Current Calculations Introduction Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective devices based on these sections mandate that

More information

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140) 9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog APC DIN Rail Control Panel Mounting Uninterruptible Power Supply Catalog 2014 Contents Introduction, description... 4 Specifications...5 References....6 Dimensions...7 Wiring diagrams....8 Product reference

More information

MAJORSINE Power Inverter

MAJORSINE Power Inverter MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

How To Test A Power Switch On A Power Supply

How To Test A Power Switch On A Power Supply transfer switches Soft load Innovative, reliable, integrated solution Built with years of experience Powered with innovation Delivered with reliability A history of experience, innovation and reliability

More information

THERMAL MANAGEMENT SOLUTIONS

THERMAL MANAGEMENT SOLUTIONS t2000 Series Electronic heat-tracing controller Product Overview /COMMUNICATIONS INTERACE CARRIER REQ TO SEND The DigiTrace heat trace controller is designed to provide the benefits associated with single

More information

Engineers Edge, LLC PDH & Professional Training

Engineers Edge, LLC PDH & Professional Training 510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 Engineers Edge, LLC PDH & Professional Training Copyright, All Rights Reserved Engineers Edge, LLC An Introduction to Interior

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V APC Smart-UPS, 670 Watts / 1000 VA,Input 230V / Output 230V, Interface Port DB-9 RS-232, SmartSlot, USB Includes: CD with software, Smart UPS signalling

More information

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from

More information

Fundamentals of Power

Fundamentals of Power Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At

More information

Medium Voltage Motor Control Assemblies

Medium Voltage Motor Control Assemblies Medium Voltage Motor Control Assemblies Arc Resistant AMPGARD.1 Product............................................. 2 Application........................................... 2 Features, Benefits and Functions...................................

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Data Center Power Overload Protection: Circuit breakers and branch circuit protection for data centers

Data Center Power Overload Protection: Circuit breakers and branch circuit protection for data centers Data Center Power Overload Protection: Circuit breakers and branch circuit protection for data centers 2009, Raritan Inc. Introduction Over the past few years, average power consumption per server has

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

TSn SERIES Surge Protective Device

TSn SERIES Surge Protective Device Page: 1 of 8 TSn SERIES Surge Protective Installation & Operation Manual 3621 Saunders Avenue www.systems.us Ph 804.355.1100 Richmond, VA 23227 4354 Sales@Systems.us Fax 804.355.8900 Page: 2 of 8 Quick

More information

UL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training. 2002 Eaton Corporation. All rights reserved.

UL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training. 2002 Eaton Corporation. All rights reserved. UL 508A Industrial Control Panels Power Distribution and Control Lunch & Learn Training 2002 Eaton Corporation. All rights reserved. Agenda Who is UL and what role do they play? What is the UL 508A Standard?

More information

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5 AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves White Paper July 2010 Integrating surge protective devices (SPD) into distribution equipment (i.e. switchgear, switchboards,

More information

Liebert PPC Second Generation Power Distribution Cabinet

Liebert PPC Second Generation Power Distribution Cabinet Liebert PPC Second Generation Power Distribution Cabinet Emerson Network Power Delivers The Packaged Power Solution Creating high quality power is a major step towards protecting the operation of a critical

More information

Corner-Grounded Delta (Grounded B Phase) Systems

Corner-Grounded Delta (Grounded B Phase) Systems Data Bulletin 2700DB0202R03/12 09/2012 Replaces 2700DB0202R2/09 dated 02/2009 Corner-Grounded Delta (Grounded B Phase) Systems Class 2700 Retain for future use. Introduction Corner-grounded delta systems

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps

More information

SENTRON Switching and Protection Devices Air Circuit Breakers

SENTRON Switching and Protection Devices Air Circuit Breakers Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General

More information

Introduction. Upon completion of Basics of Switchboards you should be able to: Explain the role of switchboards in a distribution system

Introduction. Upon completion of Basics of Switchboards you should be able to: Explain the role of switchboards in a distribution system Table of Contents Introduction... 2 Distribution Systems... 4 Switchboard Definition... 9 Switchboard Construction... 12 Service Entrance Equipment... 18 Service Section... 20 Switchboard Grounding...

More information

Primary and Secondary Electrical Distribution Systems

Primary and Secondary Electrical Distribution Systems Primary and Secondary Electrical Distribution Systems Critical Facilities Round Table 12th Quarterly Membership Meeting June 2, 2006 David D. Roybal. P.E. Eaton Electrical Cutler-Hammer Products Utility

More information

How to reduce exposure to arc flash hazards

How to reduce exposure to arc flash hazards GE Energy Industrial Solutions How to reduce exposure to arc flash hazards Multiple solutions for new and existing facilities imagination at work Multiple Issues Today s power system engineer must not

More information

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D 12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Distribution Dry Type Transformers

Distribution Dry Type Transformers Distribution Dry Type s Sentron Power Centers Bolt-in Breaker Option The same economical space saving package, NEMA 3R rated enclosure, and UL listed transformer of the original Sentron Power Center but

More information

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved. ENGLISH EATS6 EATS6N Installation and user manual Copyright 05 EATON All rights reserved. Service and suppt: Call your local service representative SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. This manual

More information

Intersection Preassembled 19-inch Rack

Intersection Preassembled 19-inch Rack Intersection Preassembled 19-inch Rack The intersection preassembled 19-inch rack comes fully assembled, wired and ready to be installed in a server rack. The rack provides communications, power conversion

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Guidelines on the Short Circuit Current Rating for Industrial Control Panels usa.siemens.com/sccr Guidelines on the Short Circuit Current Rating for Industrial Control Panels Technical Paper for Practical Applications White Paper I October 2014 As per NEC Edition 2014, and UL508A

More information

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity Proper Application of 415V Systems in North American Data Centers A White Paper from the Experts in Business-Critical Continuity Introduction Increasing pressure to reduce operating expenses and be more

More information

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS Smart-UPS Advanced line interactive power protection for servers and network equipment The world s most popular network and server UPS The award-winning Smart-UPS unit from APC by Schneider Electric is

More information

Rule 5.500 Fast Track Analysis for National Life Insurance Co.

Rule 5.500 Fast Track Analysis for National Life Insurance Co. Rule 5.500 Fast Track Analysis for National Life Insurance Co. For a 500 kw Solar array to be located at 155 Northfield Street in Montpelier, Vermont Green Mountain Power Pam Allen Date: 5/31/13 SECTION

More information

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS POWER DISTRIBUTION RACKS IN A MISSION CRITICAL SYSTEM MODULES IN A MISSION CRITICAL SYSTEM UPS Convertor Main Inverter Load Battery BPC UPS & BATTERY

More information

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic

More information

APC 3Phase Power Distribution

APC 3Phase Power Distribution APC 3Phase Power Distribution North American 3 Phase Business Development Team All content in this presentation is protected 2008 American Power Conversion Corporation Objectives Understand the entire

More information

Low Voltage Transformer Through-Fault Protection: A System Approach

Low Voltage Transformer Through-Fault Protection: A System Approach Data Bulletin 7400DB1001 Nashville, TN USA Low Voltage Transformer Through-Fault Protection: A System Approach Introduction Low Voltage Transformer Protection Criteria NEC Article 450 Transformers and

More information

Table of Contents. TransformerIQ FAQs 1

Table of Contents. TransformerIQ FAQs 1 [12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is

More information

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services. Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services. Spending too much time and money on equipment maintenance? Square D Services: Your source for circuit breaker

More information

Tmax MCCBs. Molded case circuit breakers. Tmax

Tmax MCCBs. Molded case circuit breakers. Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high

More information

32VFD Variable Frequency Drives for Centrifugal Chillers

32VFD Variable Frequency Drives for Centrifugal Chillers 32VFD 32VFD Variable Frequency Drives for Centrifugal Chillers ENERGY-SAVING CONTROL FOR CENTRIFUGAL CHILLERS Reduce energy consumption in your existing centrifugal chiller Your chiller was specified to

More information

Services. Three Phase Service

Services. Three Phase Service Services Primary Service vs Secondary Service Overhead vs Underground Common Service Types Three Phase Wye Closed Open Delta Corner Grounded Center Tapped Open Single Phase Three Phase Service Wye Delta

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services Introduction Power Distribution Equipment is a term generally used to describe any apparatus used for the generation,

More information

Data Assessment for Electrical Surge Protection Devices

Data Assessment for Electrical Surge Protection Devices Data Assessment for Electrical Surge Protection Devices Phase 1 Final Report Prepared by: Eddie Davis Nick Kooiman Kylash Viswanathan Hughes Associates, Inc. Vancouver, Washington 98660 October 2014 Fire

More information

Product Information Sheet UH28CS-12kV Hi Pot Tester

Product Information Sheet UH28CS-12kV Hi Pot Tester Product Information Sheet UH28CS-12kV ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet:

More information

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display

More information

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants Introduction This document explains how to install Furse Electronic Systems s for mains power supplies: Single

More information

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

Grounding of Electrical Systems NEW CODE: Grounding and Bonding Grounding of Electrical Systems NEW CODE: Grounding and Bonding Presented By Scott Peele PE Grounding of Electrical Systems Outline Defining the Terms Why should I Ground? Types of Grounding Systems Separately

More information

Electrical Grounding. Appendix C

Electrical Grounding. Appendix C Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment

More information

Magnum Mobile Generator MMG55 Specifications

Magnum Mobile Generator MMG55 Specifications Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0

More information

40.3. Control Relays and Timers

40.3. Control Relays and Timers .3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories

More information

Model CFA-24 Transparent Cable Farm Automation Switch

Model CFA-24 Transparent Cable Farm Automation Switch Model CFA-24 Transparent Cable Farm Automation Switch Ideal for Broadband Forum s ID-337 G.fast Certification and TR-249 VDSL2 Vectoring Testing High performance transparent solution designed to automate

More information

SWITCHGEAR. EGP Switchgear

SWITCHGEAR. EGP Switchgear SWITCHEA EP Switchgear Cat generator set paralleling switchgear has been designed to integrate with Cat EMCP3 generator set controls. Now you can get greater efficiency, reliability and dependability all

More information

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing U.S. patent#: 5,548,501, 6,054,865. Other patents pending. Safety agency listed. ENHANCED GRAPHIC LCD The

More information

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System MODEL NUMBER: HTR05-1U Description Tripp Lite's HTR05-1U AVR Series intelligent, Automatic Voltage Regulated

More information

Power Quality Issues, Impacts, and Mitigation for Industrial Customers

Power Quality Issues, Impacts, and Mitigation for Industrial Customers Power Quality Issues, Impacts, and Mitigation for Industrial Customers By Kevin Olikara, Power and Energy Management Products Rockwell Automation, Inc. Now, more than ever, electronic equipment and computing

More information

POWERLOGIC Circuit Monitor Series 2000

POWERLOGIC Circuit Monitor Series 2000 Class POWERLOGIC Circuit Monitor Series 2000 Features True rms metering Certified ANSI C2.6 revenue accuracy High accuracy 0.2% current and voltage Power quality readings THD, k-factor, crest factor Over

More information

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E Training is not a substitute for following corporate safety guidelines. Always refer to the latest safety

More information

Number 1 in efficiency

Number 1 in efficiency PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why

More information

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR Copyright Material IEEE Paper No. PCIC 2003-13 Eddie Wilkie Eaton Cutler-Hammer 3990 Old Tasso Road NE Cleveland, TN 37312 USA Abstract

More information

S&C BankGuard PLUS Control

S&C BankGuard PLUS Control S&C BankGuard PLUS Control For Substation Capacitor Banks and Shunt Reactors Application S&C s BankGuard PLUS Control utilizes flexible, reliable microprocessor technology to: Protect substation shunt

More information

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage

More information